A100 DIN

Enhanced Domestic Meter


The enhanced range of the successful A100 series
single phase meter from Elster provides a cost-
effective solution for one or two rate domestic
metering applications. The new meter features an
improved customer specific, multi-lingual display
with increased character size for ease of viewing.
The A100 offers the advantages of leading edge
electronic metering technology, enabling Class 1 or
Class 2 accuracy, anti-tamper security features and
security data as standard.
The liquid crystal display provides large (7.5mm),
high contrast characters that can be viewed from a
wide angle. Chevrons identify the values being
displayed. The register values can be set at
manufacture for the number of digits and the
position of the decimal point.
Communications is provided via an IrDA port
allowing the meter registers and security data to be
read electronically using a hand-held device,
Advanced domestic metering... greatly reducing the possibility of manual meter
reading errors. The security data includes reverse
Features run count, reverse run energy total, reverse run
indication on LCD, hours spent in rate 1, hours
• Accuracy - kWh Class 1 or Class 2 spent in rate 2, power fail count, time since last
• kWh import or kWh import/export powered and cumulative hours spent in anti-creep.
• 20 years certified life
• Large digit (7.5mm) multi-lingual display with An optional pulsed output allows active energy to
chevron information indication be collected remotely and used as the basis for an
• IrDA (Infrared Data Association) output for energy management system. The pulse width and
transmitting billing, security and status data value are configured at manufacture from a range
of values.
• DIN double insulated, glass filled polycarbonate
case As a manufacturing option the same absolute data
• High security, compact design as the IrDA port or the pulsed output can be
• IP53 in accordance with EN 60529 : 1991 transmitted via an RJ11 socket or the meter's
auxiliary terminals.
Meters can be supplied to meet accuracy Class 1 or
Options
Class 2 requirements. They are approved to EN
• One or two rates controlled by external device 61036:1996 and have an ingress protection of IP53
• Auxiliary terminals configured for rate selection to EN60529:1991.
(two rate meters) and pulsing output or serial data
output
• RJ11 socket configured as pulsing output or serial
data output
Display Pulse Output
An opto-isolated pulse output can provide the
The liquid crystal display is basis for an energy management system or AMR.
programmable at These pulses are output via the auxiliary terminals
manufacture to meet a or via the RJ11 socket.
1 2 3 4 5 6 7 customer's requirements. A
typical display showing Test Indicators
1 -
2
3
kWh IMPORT
kWh EXPORT
kWh import, active is A red test output LED is provided which pulses
4
5
COUNT
DAYS:HOURS
shown. The seven marked according to kWh import consumption (import meter)
6
7
-
ACTIVE
chevrons indicate the or import/exp ort kWh consumption (import/export
1 Time in rate 1
2 Time in rate 2 information being meter). For loads above the starting current, this gives
3 Total on time
4 Anti-creep time displayed. Up to xx displays 100ms pulses modulated at approximately 8kHz. The
Made in UK
EN 61036 : 1996
can be included in the pulse rate is 1000p/kWh.
EN 61268 : 1996
display sequence.
Technical Data
Current Range 10-65A, 5-65A
Meter Configurations Voltage Range 210-250V, 105-127V
Single or two rate meters are available. The rate select for Frequency 50 or 60Hz
a two rate meter is controlled by an external time switch. System Connection 1phase 2 wire
Burden (230V) 0.66W, 8.5VA (capacitive burden)
The meter can be configured as Power Flow Insensitive Insulation 4kV RMS 50Hz
Mode at manufacture. This is a security feature that Impulse withstand 12kV 1.2/50µS 500 ohm source
allows its main kWh register to increment regardless of Display 7.5mm Characters
whether the meter is importing or exporting energy. When High contrast, wide angle
this option is enabled, the pulsing LED indicates IrDA baud rates 2400, 4800 or 9600
identically for import and export. Serial baud rates 2400 or 4800
Certified Product Life 20 years (OFGEM model)
Temperature -20° to + 55° C (Operational range)
-25° to + 85° C (Storage)
IrDA Communications Humidity Annual Mean 75% (For 30 days spread
The IrDA (Infrared over one year, 95%)
Data Association) Pulse Output (230V) 100ms pulse 200 p /kWh (=5Wh/pulse)
communications port (Other pulse rates, durations, available)
provides one way Weight 340 grams
communications, Specifications kWh Class 1 or 2 EN 61036 : 1996
Case IP 53 to EN 60529 : 1991
transmitting a continual
data stream from the
meter to an external Terminal Arrangements
device. An error Single Rate Two Rate
checking algorithm protects the integrity of the data.
As an option the same absolute data as from the IrDA
port is available via the serial data port. The serial port
can be configured via the RJ11 socket or auxiliary
terminals.
Important information is provided:
1. Absolute meter readings
Dimensions and Fixing Centres
2. Access to security register's, status and
identification data.
A manufacturing option allows transmission speeds of
2400, 4800 (serial data port is not configured) or 9600
baud without the serial port. The port will transmit
over a distance of 250mm.

Elster Metering Systems


Oulton Road, Stone,
Staffordshire,
ST15 0RS
Tel: 44 (0) 1785 812111 Our policy is one of continuous product development and the right is reserved to supply
Fax: 44 (0) 1785 818804 equipment which may vary slightly from that described.

www.elstermetering.com
A100DIN 1B 6/1/2003
A100 BS
Enhanced Domestic Meter
The enhanced range of the successful A100 series
single phase meter from Elster provides a cost-
effective solution for one or two rate domestic
metering applications. The new meter features an
improved customer specific, multi-lingual display
with increased character size for ease of viewing.
The A100 offers the advantages of leading edge
electronic metering technology, enabling Class 1 or
Class 2 accuracy, anti-tamper security features and
security data as standard.
The liquid crystal display provides large (7.5mm),
high contrast characters that can be viewed from a
wide angle. Chevrons identify the values being
displayed. The register values can be set at
manufacture for the number of digits and the
position of the decimal point.
Communications is provided via an IrDA port
allowing the meter registers and security data to be
read electronically using a hand-held device,
greatly reducing the possibility of manual meter
reading errors. The security data includes reverse
Advanced domestic metering... run count, reverse run energy total, reverse run
indication on LCD, hours spent in rate 1, hours
Features spent in rate 2, power fail count, time since last
powered and cumulative hours spent in anti-creep.
• Accuracy - kWh Class 1 or Class 2
• kWh import or kWh import/export An optional pulsed output allows active energy to
• 20 years certified life be collected remotely and used as the basis for an
energy management system. The pulse width and
• Large digit (7.5mm) multi-lingual display with
value are configured at manufacture from a range
chevron information indication
of values.
• IrDA (Infrared Data Association) output for
transmitting billing, security and status data As a manufacturing option the same absolute data
• BS double insulated, glass filled polycarbonate as the IrDA port or the pulsed output can be
case transmitted via an RJ11 socket or the meter's
• High security, compact design auxiliary terminals.
• IP53 in accordance with EN 60529 : 1991 Meters can be supplied to meet accuracy Class 1 or
Class 2 requirements. They are approved to EN
61036:1996 and have an ingress protection of IP53
Options to EN60529:1991.
• One or two rates controlled by external device
• Auxiliary terminals configured for rate selection
(two rate meters) and pulsing output or serial data
output
• RJ11 socket configured as pulsing output or serial
data output
• Extended terminal cover
Display Pulse Output
An opto-isolated pulse output can provide the
The liquid crystal display is basis for an energy management system or AMR.
programmable at These pulses are output via the auxiliary terminals
manufacture to meet a or via the RJ11 socket.
1 2 3 4 5 6 7 customer's requirements. A
typical display showing Test Indicators
1 -
2
3
kWh IMPORT
kWh EXPORT
kWh import, active is A red test output LED is provided which pulses
4
5
COUNT
DAYS:HOURS
shown. The seven marked according to kWh import consumption (import meter)
6
7
-
ACTIVE
chevrons indicate the or import/export kWh consumption (import/export
1 Time in rate 1
2 Time in rate 2 information being meter). For loads above the starting current, this gives
3 Total on time
4 Anti-creep time displayed. 100ms pulses modulated at approximately 8kHz. The
Made in UK
EN 61036 : 1996
pulse rate is 1000p/kWh.
EN 61268 : 1996

Technical Data
Current Range 20-100A, 10-100A
Meter Configurations Voltage Range 210-250V, 105-127V
Single or two rate meters are available. The rate select for Frequency 50 or 60Hz
a two rate meter is controlled by an external time switch. System Connection 1phase 2 wire
Burden (230V) 0.66W, 8.5VA (capacitive burden)
The meter can be configured as Power Flow Insensitive Insulation 4kV RMS 50Hz
Mode at manufacture. This is a security feature that Impulse withstand 12kV 1.2/50µS 500 ohm source
allows its main kWh register to increment regardless of Display 7.5mm Characters
whether the meter is importing or exporting energy. When High contrast, wide angle
this option is enabled, the pulsing LED indicates IrDA baud rates 2400, 4800 or 9600
identically for import and export. Serial baud rates 2400 or 4800
Certified Product Life 20 years (OFGEM model)
Temperature -20° to + 55° C (Operational range)
-25° to + 85° C (Storage)
IrDA Communications Humidity Annual Mean 75% (For 30 days spread
The IrDA (Infrared Data over one year, 95%)
Association) Pulse Output (230V) 100ms pulse 100 p /kWh (=10Wh/pulse)
communications port (Other pulse rates, durations, available)
provides one way Weight 390 grams
communications, Specifications kWh Class 1 or 2 EN 61036 : 1996
Case IP 53 to EN 60529 : 1991
transmitting a continual
data stream from the
meter to an external
device. An error Terminal Arrangements
checking algorithm 1 2 3 4 1 2 3 4
protects the integrity of the data. As an option the same
absolute data as from the IrDA port is available via the L L L L
serial data port. The serial port can be configured via N N N N
the RJ11 socket or auxiliary terminals. MAIN LOAD MAIN LOAD

Important information is provided: Single Rate Two Rate


1. Absolute meter readings Dimensions and Fixing Centres
2. Access to security register's, status and
identification data.
A manufacturing option allows transmission speeds of
2400, 4800 (serial data port is not configured) or 9600
baud without the serial port. The port will transmit
over a distance of 250mm.

Elster Metering Systems


Oulton Road, Stone,
Staffordshire,
ST15 0RS
Tel: 44 (0) 1785 812111 Our policy is one of continuous product development and the right is reserved to supply
equipment which may vary slightly from that described.
Fax: 44 (0) 1785 818804

www.elstermetering.com