Dade Innovin: Intended Use Summary and Explanation

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

B4212 G40 E0501 (837)

Dade® Innovin®
Intended Use Internal Quality Control
For use in prothrombin time (PT) determinations and prothrombin time-based assays in citrated human Normal range: Dade® Ci-Trol® Level 1 or Control Plasma N
plasma. Pathological range: Dade® Ci-Trol® Level 2, Dade® Ci-Trol® Level 3 or Control Plasma P
Two levels of quality control material (normal and pathological range) must be measured at start of the
Summary and Explanation test run, with each calibration, upon reagent vial changes and at least every eight hours on each day
Dade® Innovin® Reagent is prepared from purified recombinant human tissue factor produced in E. coli, of testing.
combined with synthetic phospholipids (thromboplastin)1, calcium, buffers and stabilizers. The reagent The control material should be prepared and processed in the same manner as the samples.
initiates clotting via the extrinsic and common pathways in a global screening test, the prothrombin time A range of allowable variation should be established for controls in each laboratory. New control ranges
(PT). Dade® Innovin® Reagent has three major applications based upon the PT2: should be established for each lot of reagent or control material. This range is usually based on ± 2.5
1. as a rapid screening test to detect single or combined deficiencies of the extrinsic coagulation system standard deviations (SD) from the control mean.
indicative of hereditary and acquired coagulation disorders, liver disease or vitamin K deficiency; If the control values are outside of the confidence interval, check the coagulation analyzer, controls and
2. as a sensitive monitoring test for oral anticoagulant therapy; and reagents. Do not release patient results until the cause of deviation has been identified and corrected.
3. as an assay for specific coagulation factors. Results
Additionally, various photo-optical coagulation analyzers are able to derive the fibrinogen value from the Currently, various methods are used for reporting PT results. ISI (International Sensitivity Index) values
determination of the prothrombin time. for Dade® Innovin® Reagent are provided for the particular reagent/instrument combination; these enable
Dade® Innovin® Reagent is manufactured using recombinant human tissue factor and synthetic phos- the results to be reported in INR (International Normalized Ratio)4. Computation and use of the INR are
pholipids which do not contain any other clotting factors such as prothrombin, F VII and F X. Therefore, described below. The INR system is the preferred method for reporting results for oral anticoagulated
it is highly sensitive to factor deficiencies and oral anticoagulant-treated patient plasma samples. The patient specimens. Alternatively, the patient’s PT (in seconds) together with the reference range (in
sensitivity of Dade® Innovin® Reagent is very similar to the WHO human brain reference thromboplastin3. seconds) can be used to report results.
Dade® Innovin® Reagent is insensitive to therapeutic levels of heparin. The high sensitivity of Dade® Example: patient result of 18 seconds; reference range 9.7 - 12.3 seconds.
Innovin® Reagent to coagulation factors and its insensitivity to therapeutic heparin make it beneficial Determination of INR (International Normalized Ratio)
in monitoring oral anticoagulant therapy3. In addition, its high sensitivity (i.e. the responsiveness of the
reagent to moderately depleted factor activity) allows differentiation of abnormal plasmas, even in the Values using Dade® Innovin® Reagent
mildly pathological range. International PT (Prothrombin Time) Standardization for Oral Anticoagulant Therapy Monitoring
1. According to the joint recommendations of the World Health Organization (WHO)4 and the Interna-
Principle of the Method tional Committee on Thrombosis and Haemostasis, the PT results for patients on oral anticoagulants
The coagulation cascade is activated by incubating plasma with the optimal amount of thromboplastin should be reported as INR values. Reported INR results are independent of the reagents and meth-
and calcium; the clotting time is then measured. ods used, and are specifically intended for assessing patients stabilized on long-term oral anticoagu-
lant therapy.
Reagents The INR is determined4 according to the following equation:
Materials provided Patient PT
10 x l 4 mL, [REF] B4212-40 INR = RISI, where R = ——————————
Mean normal PT**
10 x l 10 mL, [REF] B4212-50
12 x l 20 mL, [REF] B4212-100 ISI is the International Sensitivity Index of the reagent/instrument combination.
The ISI values for Siemens thromboplastin reagents are determined in accordance with WHO
Composition recommendations.
Dade® Innovin® Reagent: Lyophilized reagent consisting of recombinant human tissue factor and syn- 2. Methods of INR calculation:
thetic phospholipids (thromboplastin), calcium ions, a heparin-neutralizing compound, buffers and sta- a. Calculators with exponential functions:
bilizers (bovine serum albumin).
These instructions refer specifically to the Texas Instruments TI-55 II calculator. Other calculators,
Warnings and Precautions e.g. Hewlett-Packard models, may require different key stroke sequences. Consult the calculator
For in-vitro diagnostic use. reference manual and check example problems against the Conversion Table to assure mastery
Reagent Preparation of conversion procedures.
Enter Patient PT in seconds, press ”÷”, enter MNPT**, press ”=”. The display will now show R, the
Reconstitute a vial of lyophilized Dade® Innovin® Reagent with distilled or deionized water using the Patient Ratio. Now press the ”yx” key, then enter the specific ISI value of the thromboplastin/instru-
volume stated on the vial label. Store at +2 to +8 °C. ment combination used and press ”=”. The result displayed is the patient’s INR value.
To ensure complete reconstitution, thoroughly mix the contents of the vial immediately after adding Press Notes
the water. If left to stand, Dade® Innovin® Reagent should be re-mixed before use in order to ensure a
homogeneous solution. Continuous mixing is not necessary. Example: 24 patient PT
Note: Do not use water that contains preservatives. ÷ divided by
11.0 MNPT**
Storage and Stability = patient ratio (display shows 2.1818)
Store at +2 to +8 °C. At this temperature, the unopened reagent can be used until its expiry date (see yx exponential function key
vial label).
1.1 example ISI value
Stability after reconstitution: +2 to +8 °C 10 days (closed vial) = result: INR (display shows 2.3588)
+15 to +25 °C 5 days (closed vial) Report as INR = 2.4
+37 °C 24 hours (closed vial) b. Conversion Table:
Information about on-board stability is specified in the Reference Guides (Application Sheets) for the First, calculate the patient PT/MNPT** ratio, R. The INR value can then be read from the enclosed
different coagulation analyzers. INR Conversion Table by looking in the column under the appropriate ISI value, in the row that
Do not freeze! corresponds to the patient’s PT ratio (R).
Signs of expiry: Absence of vacuum when opening the vial; reagent is difficult to reconstitute; results c. Automatic:
are not reproducible. INR values can be computed automatically by various coagulometers. For details, consult the
Materials required but not provided relevant instruction manual. Specific coagulation analyzer protocols are available from Siemens on
request.
Control Plasma N or Dade® Ci-Trol® Level 1
Control Plasma P, Dade® Ci-Trol® Level 2 or Dade® Ci-Trol® Level 3 Derived Fibrinogen
PT-Multi Calibrator* (Refer to the Instructions for Use for details on use.) Using Dade® Innovin® Reagent and the appropriate assay on Siemens photometric coagulation analyz-
ers or Sysmex® coagulation analyzers, the fibrinogen concentration may be derived by analyzing the
Standard Human Plasma or fresh normal plasma4 for determining the mean normal PT (MNPT)**
change in optical signal during prothrombin time determinations, using a derived fibrinogen calibration
Sodium citrate solution (0.11 mol/L or 0.13 mol/L / 3.2 % or 3.8 %) for blood collection curve. This calibration curve (master curve) is provided by Siemens in the lot-dependent Table of As-
Distilled or deionized water without preservatives signed Values.
Plastic tubes
Plastic transfer pipettes Limitations of the Procedure
Pipettes for precise measurement of 20.0 mL, 10.0 mL, 1.0 mL, 0.50 mL, 0.20 mL and 0.10 mL There are no other clotting factors in recombinant human tissue factor. Factor assay curves using Dade®
Coagulation analyzer Innovin® Reagent may therefore give longer clotting times at the lowest levels of the deficient factor than
with other reagents. This may result in clotting times greater than 100 seconds for low factor levels in
Equipment factor assay curves.
Dade® Innovin® Reagent can be used manually or on automated coagulation analyzers. Siemens Health- Siemens has validated use of these reagents on various analyzers to optimize product performance and
care Diagnostics provides Reference Guides (Application Sheets) for several coagulation analyzers. meet product specifications. User defined modifications are not supported by Siemens as they may affect
The Reference Guides (Application Sheets) contain analyzer/assay specific handling and performance performance of the system and assay results. It is the responsibility of the user to validate modifications to
information which may differ from that provided in these Instructions for Use. In this case, the information these instructions or use of the reagents on analyzers other than those included in Siemens Application
contained in the Reference Guides (Application Sheets) supersedes the information in these Instructions Sheets or these instructions for use.
for Use. Please also consult the instruction manual of the instrument manufacturer! Results of this test should always be interpreted in conjunction with the patient’s medical history, clinical
Specimen Collection and Preparation presentation and other findings.
Mix nine parts of freshly collected patient blood with one part of 0.11 or 0.13 mol/L (3.2 % or 3.8 %) Interfering Substances
sodium citrate solution. An evacuated tube system or syringe may be used. Many commonly administered drugs may affect the results obtained in prothrombin time testing4. This
Centrifuge the blood specimen at 1500 x g for no less than 15 minutes at room temperature. should be kept in mind especially when unusual or unexpected abnormal results are obtained. Unex-
Store in an unopened tube at room temperature. Do not store on ice or at +2 to +8 °C as cold activation pected abnormal results should be followed by additional coagulation studies to determine the source
of F VII may alter results. Plasma should be tested within 24 hours of blood collection. Samples should of the abnormality.
not stand at +37 °C for more than 5 minutes. If the patient is on both heparin and coumarin-based anti- Turbidity of lipemic samples, e.g. with parenteral feeding, may preclude accuracy in the derived fibrino-
coagulant therapy, the results may vary with time of storage. gen determination.
Please refer to CLSI document H21-A55 for detailed information on sample preparation and storage. Dade® Innovin® Reagent is insensitive to concentrations of unfractionated heparin up to approximately
2.0 units per mL. The heparin sensitivity study was conducted using spiked normal pooled plasma and
Procedure the sensitivity to heparin was defined by the concentration of heparin in the specimen that prolonged the
PT results exceeding the upper limit of the reference range.
Manual Testing:
Inhibitors such as lupus anticoagulant may interfere with the prothrombin time and result for example in
Prewarm Dade® Innovin® Reagent to +37 °C. INRs that do not reflect the exact degree of anticoagulation6. Hirudin or other direct thrombin inhibitors in
Pipet into coagulation tubes as follows: therapeutic dose result in prolonged prothrombin times7,8.

Test Sample Control Expected Values


Values for healthy individuals vary from laboratory to laboratory depending on the technique used.
Plasma 0.1 mL - Therefore, each laboratory should establish its own reference intervals based on the procedure and
Control - 0.1 mL coagulation analyzers used.
Incubate tubes and samples for 1 - 2 minutes In a study with ostensibly healthy subjects (n = 138), the following reference interval (5th to 95th percentile)
(max. 5 minutes) at +37 °C was determined:
Sysmex® CA-7000 system: Central 90 % reference interval: 10.4 to 12.4 seconds
Add prewarmed Dade® Innovin® Reagent 0.2 mL 0.2 mL Derived fibrinogen9: 1.8 - 3.5 g/L
Start stopwatch simultaneously with addition of Dade® Innovin® Reagent. Observe time of clot formation. Therapeutic Ranges
Therapeutic ranges for INR may vary depending on the indication of oral anticoagulant therapy10.

B4212 G40 E0501 (837) 1


Specific Performance Characteristics Die Angaben zur Stabilität auf dem Gerät sind in den Referenzhandbüchern (Applikationsvorschriften)
für die einzelnen Gerinnungsmessgeräte aufgeführt.
Precision Nicht einfrieren!
Precision of prothrombin time results is generally limited by the method used. Therefore, within a single lot,
the reagent should yield results which are reproducible within the quality control of the laboratory. Hinweis auf Verfall: fehlendes Vakuum beim Öffnen des Fläschchens; Reagenz läßt sich nur schwer
The precision of Dade® Innovin® Reagent on the Sysmex® CA-6000 system was estimated with quality lösen; es lassen sich keine reproduzierbaren Werte erreichen.
control material from a total of six (6) separate runs over three (3) testing days (two runs per day) and Zusätzlich benötigte Materialien
four (4) replicates per control level, per run with the following results:
Kontroll-Plasma N oder Dade® Ci-Trol® Level 1
Kontroll-Plasma P, Dade® Ci-Trol® Level 2 oder Dade® Ci-Trol® Level 3
Coefficient of Variation
PT-Multi Calibrator* (Einzelheiten zum Gebrauch entnehmen Sie bitte der Gebrauchsanweisung.)
Assay Control Level n Mean Within Run Run to Run Total Standard Human-Plasma oder frisches Normalplasma4 zur Bestimmung der MNPT**
Prothrombin Time 1 24 12.4 s 1.3 % 2.0 % 2.4 % Natriumcitrat-Lösung (0,11 mol/l oder 0,13 mol/l bzw. 3,2 %ig oder 3,8 %ig) für die Blutentnahme
2 24 33.0 s 0.7 % 3.4 % 3.5 % Destilliertes oder entionisiertes Wasser ohne Konservierungsstoffe
Derived Fibrinogen 1 24 2.37 g/L 4.0 % 2.8 % 4.9 % Kunststoffröhrchen
2 24 3.37 g/L 4.1 % 3.0 % 5.1 % Kunststoffpipetten für den Probentransfer
Pipetten für das genaue Abmessen von 20,0 ml, 10,0 ml, 1,0 ml, 0,50 ml, 0,20 ml und 0,10 ml
Bibliography Gerinnungsmessgerät
1. Spicer EK, Horton R, Bloem L, et al. Isolation of cDNA clones coding for human tissue factor:
Primary structure of the protein and cDNA. Proc Natl Acad Sci USA. 1987; 84:5148-52. Geräte
2. Quick AJ. Hemorrhagic diseases and thrombosis. Philadelphia: Lea and Febiger; 1966. Dade® Innovin® Reagenz kann manuell oder an automatischen Gerinnungsmessgeräten verwendet werden.
3. Bader R, Mannucci PM, Tripodi A, et al. Multicentric evaluation of a new PT reagent based on recom- Siemens Healthcare Diagnostics stellt für verschiedene Gerinnungsmessgeräte Referenzhandbücher
binant human tissue factor and synthetic phospholipids. Thromb Haemost. 1994;71:292-9. (Applikationsvorschriften) zur Verfügung. Diese enthalten geräte-/ testspezifische Informationen zur
Abarbeitung und zu Leistungsdaten, die von den Informationen in dieser Gebrauchsanweisung abweichen
4. Poller L. The Prothrombin Time. WHO/LAB/98.3. 1998. können. In diesem Fall ersetzen die Informationen in den Referenzhandbüchern (Applikationsvorschriften)
5. CLSI. Collection, Transport, and Processing of Blood Specimens for Testing Plasma-Based Coagu- die Informationen in dieser Gebrauchsanweisung. Bitte auch die Bedienungsanleitung des Geräteherstellers
lation Assays and Molecular Hemostasis Assays. Approved Guideline - Fifth Edition. CLSI docu- beachten!
ment H21-A5 [ISBN 1-56238-657-3]. CLSI, 940 West Valley Road, Suite 1400, Wayne, Pennsylva-
nia 19087-1898 USA, 2008. Probenabnahme und -vorbereitung
6. Tripodi A, Chantarangkul V, Clerici M, et al. Laboratory control of oral anticoagulant treatment by Neun Teile frisch abgenommenes Patientenblut mit einem Teil Natriumcitrat-Lösung (0,11 mol/l oder
the INR system in patients with the antiphospholipid syndrome and lupus anticoagulant. Results of 0,13 mol/l bzw. 3,2 %ig oder 3,8 %ig) mischen. Es können Blutentnahmesysteme mit evakuierten
a collaborative study involving nine commercial thromoplastins. Br J Haematol. 2001;115:672-8. Gefäßen oder die Abnahme in der Spritzentechnik angewandt werden.
7. Tobu M, Iqbal O, Messmore HL, et al. Influence of different anticoagulant agents on fibrinopeptide Die Blutprobe soll bei 1500 x g für nicht weniger als 15 Minuten bei Raumtemperatur zentrifugiert
A generation. Clin Appl Thromb Hemost. 2003;9:273-92. werden.
8. Fenyvesi T, Joerg I, Harenberg J. Influence of Lepirudin, Argatroban, and Melagatran on pro- Im ungeöffneten Abnahmeröhrchen bei Raumtemperatur lagern. Nicht auf Eis oder bei +2 bis +8 °C
thrombin time and additional effect of oral anticoagulation. Clin Chem. 2002;48:1791-4. lagern, da eine Kälteaktivierung von F VII die Ergebnisse verändern könnte. Das Patientenplasma
9. Wagner C, Dati F. Fibrinogen. In: Thomas L, ed. Clinical Laboratory Diagnostics. Frankfurt: TH- sollte innerhalb von 24 Stunden nach der Blutabnahme analysiert werden. Bei +37 °C dürfen die
Books Verlagsgesellschaft, 1998: 609-12. Proben nicht länger als 5 Minuten stehen bleiben. Bei Patienten mit Heparin und Coumarin basierter
10. Hirsh J, Dalen JE, Anderson DR, et al. Oral anticoagulants: Mechanism of action, clinical effective- Antikoagulanzientherapie können die Ergebnisse in Abhängigkeit von der Standzeit variieren.
ness, and optimal therapeutic range. Chest. 2001;119:8S-21S. Genaue Angaben zur Probenentnahme und -lagerung entnehmen Sie bitte dem CLSI-Document H21-A55.
* Not available in the USA
** The mean normal PT is defined as the mean value of the normal range. It must be determined specifi- Testdurchführung
cally for each thromboplastin lot using the method used to analyze the patient samples and, where Manuelle Durchführung:
appropriate, using the coagulometer used for the analysis. Dade® Innovin® Reagenz auf +37 °C vorwärmen.
Ci-Trol, Dade and Innovin are trademarks of Siemens Healthcare Diagnostics. In die Kunststoffröhrchen wie folgt pipettieren:
Sysmex is a registered trademark of SYSMEX CORPORATION.
Testprobe Kontrolle
Purchase of Dade® Innovin® provides the purchaser with a limited license to use the purchased Dade®
Innovin® covered by U.S. Patent Nos. 5,625,036; 7,084,251 and 7,049,131 in accordance with the In- Plasma 0,1 ml -
structions for Use set forth herein. Kontrolle - 0,1 ml
Proben in den Röhrchen 1 bis 2 Minuten (max. 5 Minuten)
bei +37 °C inkubieren
Vorgewärmtes Dade® Innovin® Reagenz rasch zugeben 0,2 ml 0,2 ml
USA Distributor: Siemens Healthcare Diagnostics Inc. Bei Zugabe von Dade® Innovin® Reagenz ist die Stoppuhr starten, um die Zeit bis zur Gerinnselbildung
Newark, DE 19714 U.S.A. zu messen.
Edition May 2008 Interne Qualitätskontrolle
Normalbereich: Dade® Ci-Trol® Level 1 oder Kontroll-Plasma N

Dade® Innovin®
Pathologischer Bereich: Dade® Ci-Trol® Level 2, Dade® Ci-Trol® Level 3 oder Kontroll-Plasma P
Bei jedem Wechsel der Reagenzflaschen, zu Beginn eines Testlaufes, nach jeder Kalibration und
mindestens alle 8 Stunden an jedem Testtag müssen zwei Kontrollen (eine im Normalbereich und eine
Anwendungsgebiet im pathologischen Bereich) gemessen werden. Das Kontrollmaterial sollte wie zu untersuchende Proben
behandelt werden.
Für die Bestimmung der Thromboplastinzeit (TPZ) und für darauf basierende Tests in humanem Citratplasma.
Jedes Labor sollte seinen eigenen Vertrauensbereich für die Kontrollen ermitteln. Bei jeder neuen Reagenzien-
Diagnostische Bedeutung oder Kontrollencharge sollten neue Kontrollbereiche definiert werden. Diese betragen in der Regel
± 2,5 Standardabweichungen (SD) vom mittleren Kontrollwert.
Dade® Innovin® Reagenz ist ein in E. coli produzierter, gereinigter rekombinanter humaner Gewebefaktor,
kombiniert mit synthetischen Phospholipiden (Thromboplastin)1, Calcium, Puffer und Stabilisatoren. Das Liegen die Kontrollwerte außerhalb des Vertrauensbereichs, sollten das Gerinnungsmessgerät, die
Reagenz induziert die Gerinnselbildung über den exogenen Aktivierungsweg und die gemeinsame Kontrollen und die Reagenzien überprüft werden. Die Ergebnisse der Patientenproben dürfen nicht
Endstrecke in einem globalen Screening-Test, der Bestimmung der Thromboplastinzeit (TPZ). Dade® freigegeben werden, bevor der Grund der Abweichung eruiert und korrigiert wurde.
Innovin® Reagenz wird für drei auf der TPZ2 basierende Hauptanwendungen genutzt: Auswertung
1. als rascher Screening-Test zum Nachweis einzelner oder kombinierter Mängel extrinsischer Zur Darstellung von TPZ-Werten finden derzeit verschiedene Methoden Anwendung. Für Dade® Innovin®
Gerinnungsmechanismen, durch den angeborene oder erworbene Gerinnungsstörungen, Reagenz gibt es einen chargen- und gerätespezifischen "International Sensitivity Index" -Wert (ISI), der
Lebererkrankungen oder Vitamin K-Mangel erkannt werden können; die Angabe der Patientenwerte als "International Normalized Ratio" (INR) ermöglicht4. Berechnung und
2. als empfindlicher Test zum Monitoring von oralen Antikoagulanzientherapien und Anwendung der INR sind unten beschrieben. Die Angabe in INR wird bevorzugt zur Dokumentation von
3. zur Bestimmung der exogenen Gerinnungsfaktoren. Ergebnissen für oral-antikoagulierte Patientenproben eingesetzt. Alternativ kann die Patienten-TPZ (in
Verschiedene photo-optische Gerinnungsmessgeräte sind zusätzlich in der Lage, den Fibrinogenwert Sekunden) zusammen mit dem Referenzbereich (in Sekunden) zur Ergebnismitteilung genutzt werden.
während der Bestimmung der Thromboplastinzeit abzuleiten. Beispiel: Patientenergebnis 18 Sekunden; Referenzbereich 9,7 - 12,3 Sekunden.
Dade® Innovin® Reagenz wird aus rekombinantem humanem Gewebefaktor und synthetischen Bestimmung der INR (International Normalized Ratio)
Phospholipiden hergestellt, die keinerlei andere Gerinnungsfaktoren, wie z. B. Prothrombin, F VII oder F X Werte für Dade® Innovin® Reagenz
enthalten. Daher ist es hochsensibel gegenüber Plasmen mit Mangel an Gerinnungsfaktoren und solchen Internationale TPZ (Thromboplastinzeit) Standardisierung für das Monitoring oraler Antikoagulanzientherapien
von Patienten unter oraler Antikoagulanzientherapie. Die Empfindlichkeit von Dade® Innovin® Reagenz
kommt dem WHO-Referenzthromboplastin aus Humanhirn sehr nahe3. Hinzu kommt, dass Dade® 1. Gemäß den gemeinsamen Empfehlungen der World Health Organization (WHO)4 und des
Innovin® Reagenz gegenüber therapeutischen Heparinkonzentrationen unempfindlich ist. Aufgrund der International Committee on Thrombosis and Haemostasis sollten TPZ-Werte für Patienten unter oraler
hohen Empfindlichkeit gegenüber Gerinnungsfaktoren und der Unempfindlichkeit gegenüber Heparin Antikoagulanzientherapie als INR-Werte angegeben werden. INR-Werte sind von den verwendeten
im therapeutischen Bereich ist Dade® Innovin® Reagenz besonders gut für die Überwachung oraler Reagenzien und Methoden unabhängig und speziell für die Befundung von Patienten vorgesehen,
Antikoagulanzientherapien geeignet3. Durch die hohe Empfindlichkeit (d. h. die Reaktion des Reagenzes die mit einer langfristigen oralen Antikoagulanzientherapie stabil eingestellt sind.
auf mäßig verringerte Gerinnungsfaktorenaktivität) können sogar Plasmaproben erkannt werden, die nur Die INR wird mit der folgenden Gleichung bestimmt4:
geringgradig pathologisch sind. Patienten-TPZ
INR = RISI, wobei R = ——————————
Prinzip der Methode MNPT**
Durch Inkubation von Plasma mit der optimalen Menge an Thromboplastin und Calcium wird der
Gerinnungsvorgang ausgelöst, die Zeit bis zur Bildung des Fibringerinnsels wird gemessen. ISI ist der International Sensitivity Index der Reagenzien-/Gerätekombination.
Die ISI-Werte für Siemens Thromboplastin Reagenzien werden entsprechend den WHO-
Reagenzien Empfehlungen ermittelt.
Inhalt der Handelspackungen 2. Methoden zur Berechnung der INR:
10 x l 4 ml, [REF] B4212-40 a. Rechner mit Exponentialfunktion:
Diese Hinweise gelten speziell für den Rechner TI-55 II von Texas Instruments. Bei anderen
10 x l 10 ml, [REF] B4212-50 Rechnern, wie Hewlett-Packard-Modellen, kann die Eingabe abweichen. Hinweise finden Sie
12 x l 20 ml, [REF] B4212-100 in der Bedienungsanleitung des Rechners. Überprüfen Sie die Rechenbeispiele anhand der
Umrechnungstabelle, um Rechenfehler zu erkennen.
Zusammensetzung
Geben Sie die Patienten-TPZ in Sekunden ein, und drücken Sie ”÷”. Geben Sie nun die MNPT** ein,
Dade® Innovin® Reagenz: Lyophilisat aus rekombinantem humanem Gewebefaktor und synthetischen und drücken Sie anschließend ”=”. In der Anzeige erscheint R, die Patienten-Ratio. Drücken Sie nun die
Phospholipiden (Thromboplastin), Calciumionen, einer Heparin-neutralisierenden Verbindung, Puffer Taste „yx“, geben Sie den spezifischen ISI-Wert der verwendeten Thromboplastin-/Gerätekombination
und Stabilisatoren (Rinderserumalbumin). ein und drücken ”=”. Das angezeigte Ergebnis ist der INR-Wert der Patientenprobe.
Warnungen und Vorsichtsmaßnahmen Eingabe Erläuterung
Nur zur in-vitro diagnostischen Anwendung. Beispiel: 24 Patienten TPZ
Vorbereitung der Reagenzien ÷ geteilt durch
Ein Fläschchen Dade® Innovin® Reagenz Lyophilisat mit destilliertem oder entionisiertem Wasser 11,0 MNPT**
entsprechend der Mengenangabe auf dem Fläschchenetikett auflösen. Bei +2 bis +8 °C lagern. = Patienten-Ratio (in der Anzeige erscheint 2,1818)
Zur vollständigen Auflösung den Fläschcheninhalt sofort nach der Zugabe des Wassers gut mischen. Wird yx Taste für die Exponentialfunktion
das Fläschchen stehengelassen, sollte Dade® Innovin® Reagenz vor der Anwendung erneut gemischt 1,1 Beispiel-ISI-Wert
werden, um eine homogene Lösung zu erhalten. Kontinuierliches Mischen ist nicht erforderlich. = Ergebnis: INR (in der Anzeige erscheint 2,3588)
Hinweis: Kein Wasser mit Konservierungsstoffen verwenden. als INR 2,4 ausgeben
Haltbarkeit und Lagerungsbedingungen b. Umrechnungstabelle:
Bei +2 bis +8 °C lagern. Bei dieser Temperatur bleibt das Reagenz ungeöffnet bis zum Verfallsdatum Berechnen Sie zunächst die TPZ-Ratio, R, indem Sie die Patienten-TPZ durch die MNPT**
haltbar (siehe Fläschchenetikett). teilen. Den INR-Wert finden Sie in der beiliegenden Umrechnungstabelle in der Spalte unter dem
entsprechenden ISI-Wert und in der Zeile, die der Patienten-TPZ-Ratio (R) entspricht.
Stabilität nach Rekonstitution: +2 bis +8 °C 10 Tage (geschlossene Flasche) c. Automatisch:
+15 bis +25 °C 5 Tage (geschlossene Flasche) INR-Werte können von verschiedenen Gerinnungsmessgeräten automatisch berechnet werden.
+37 °C 24 Stunden (geschlossene Flasche) Hinweise hierzu sind in der Bedienungsanleitung zum Gerät enthalten. Spezifische Protokolle für
Gerinnungsmessgeräte sind auf Anfrage von Siemens erhältlich.

B4212 G40 E0501 (837) 2


Abgeleiteter Fibrinogenwert Principe de la méthode
Bei Verwendung eines geeigneten Tests zusammen mit photo-optisch messenden Siemens L’incubation d’un plasma avec une quantité optimale de thromboplastine et de calcium déclenche le
Gerinnungsmessgeräten und Sysmex® Gerinnungsmessgeräten kann mit diesem Reagenz auch processus de coagulation. Le temps qui s’écoule jusqu’à la formation d’un caillot de fibrine est mesuré.
die Fibrinogenkonzentration durch Analyse der Veränderung im optischen Signal während der
Thromboplastinzeit-Bestimmung abgeleitet werden. Dazu muss die Masterkurve für abgeleitetes Réactifs
Fibrinogen aus der chargenabhängigen Wertetabelle als Kalibrationskurve eingegeben werden.
Contenu des conditionnements
Einschränkungen der Testdurchführung 10 x l 4 ml, [REF] B4212-40
Bei Verwendung von Dade® Innovin® Reagenz können sich bei der Bestimmung der exogenen Faktoren
für die niedrigste Aktivität des Mangelfaktors längere Gerinnungszeiten als bei anderen Reagenzien 10 x l 10 ml, [REF] B4212-50
ergeben, da in rekombinantem humanen Gewebefaktor keine zusätzlichen Gerinnungsfaktoren enthalten 12 x l 20 ml, [REF] B4212-100
sind. So kann die Gerinnungszeit für eine niedrige Faktoraktivität mehr als 100 Sekunden betragen. Composition
Siemens hat den Einsatz dieser Reagenzien auf verschiedenen Analysengeräten auf optimale Dade® Innovin® Réactif : lyophilisat de facteur tissulaire humain, de phospholipides synthétiques
Produktleistung und Einhaltung der Produktspezifikationen überprüft. Vom Benutzer vorgenommene (thromboplastine), d’ions calcium, d’un neutralisateur d’héparine, de tampon et de stabilisateurs (albu-
Änderungen werden von Siemens nicht unterstützt, da sie die Leistung des Systems und die mine sérique bovine).
Testergebnisse beeinflussen können. Es liegt in der Verantwortung des Benutzers, Änderungen an diesen
Anleitungen oder die Verwendung dieser Reagenzien auf anderen als in den Applikationsvorschriften Mises en garde et précaution d’emploi
von Siemens oder diesen Gebrauchsanweisungen genannten Analysengeräten zu validieren. Réservé à un usage de diagnostic in vitro.
Resultate dieses Tests sollten stets in Verbindung mit der Vorgeschichte des Patienten, dem klinischen Préparation du réactif
Bild und anderen Untersuchungsergebnissen interpretiert werden.
Reconstituer le contenu d’un flacon de Dade® Innovin® Réactif lyophilisé avec de l’eau distillée ou désio-
Störfaktoren nisée, selon le volume indiqué sur l’étiquette du flacon. Conserver à +2/+8 °C.
Die Thromboplastinzeit kann durch eine Vielzahl häufig verschriebener Medikamente beeinflusst Bien mélanger immédiatement après l’addition de l’eau pour aider à l’homogénéisation complète. Si on
werden4, ein Umstand, der insbesondere beim Auftreten von unerwartet abnormalen Werten in Betracht n’utilise pas la solution immédiatement, agiter de nouveau le flacon juste avant emploi. Il est inutile de
gezogen werden sollte. Bei unerwartet abnormalen Werten muss gegebenenfalls die Ursache durch l’agiter en permanence.
weitere Gerinnungstests gesucht werden. Remarque : ne pas utiliser d’eau contenant des conservateurs.
Durch die Trübung lipämischer Proben, z. B. bei künstlicher Ernährung, kann die Richtigkeit der
abgeleiteten Fibrinogenbestimmung beeinträchtigt werden.
Stabilité et conditions de conversation
Dade® Innovin® Reagenz ist gegen unfraktionierte Heparinkonzentrationen bis zu 2,0 Einheiten/ Température de conservation : +2/+8 °C. A cette température et conservé dans son flacon non ouvert,
ml unempfindlich. Die Heparin-Sensitivitätsstudie wurde mit aufgestocktem Normalplasmapool le réactif reste stable jusqu’à la date de péremption (cf. étiquette du flacon).
durchgeführt. Die Heparinsensitivität definiert sich durch die Konzentration an Heparin in der Probe, die Stabilité après reconstitution : +2/+8 °C 10 jours (flacon fermé)
zu einer Verlängerung über den Referenzbereich hinaus führt. +15/+25 °C 5 jours (flacon fermé)
Inhibitoren wie Lupus Antikoagulans können die Thromboplastinzeit beeinflussen und beispielsweise zu +37 °C 24 heures (flacon fermé)
INR Werten führen, die nicht das genaue Maß der Antikoagulation wiedergeben6. Les données de stabilité sur les appareils de coagulation sont indiquées dans les manuels de référence
Therapeutische Dosen von Hirudin oder anderen direkten Thrombin-Inhibitoren führen zu verlängerten (protocoles d’adaptation) des différents appareils de coagulation.
Gerinnungszeiten7,8. Ne pas congeler le réactif !
Indices que le réactif est périmé : absence de vide à l’ouverture du flacon ; difficulté à dissoudre le
Referenzbereiche lyophilisat ; impossibilité à obtenir des valeurs reproductibles.
Die Werte gesunder Personen variieren von Labor zu Labor in Abhängigkeit von der angewendeten
Methode. Daher sollte jedes Labor auf der Grundlage des verwendeten Verfahrens und Autres matériel et réactifs nécessaires
Gerinnungsmessgerätes eigene Referenzbereiche ermitteln. Plasma de contrôle N ou Dade® Ci-Trol® Niveau 1
In einer Studie mit offensichtlich gesunden Personen (n = 138) wurde der folgende Referenzbereich Plasma de contrôle P, Dade® Ci-Trol® Niveau 2 ou Dade® Ci-Trol® Niveau 3
(5.- 95. Perzentile) ermittelt: PT-Multi Calibrator* (Pour obtenir des informations détaillées sur l’utilisation, consulter la notice d’utilisation).
Sysmex® CA-7000 System: Zentraler 90 %-Referenzbereich: 10,4 - 12,4 Sekunden. Plasma standard humain ou plasma normal frais4 pour déterminer le MNPT**
Abgeleitetes Fibrinogen9: 1,8 - 3,5 g/l Solution citrate de sodium (0,11 mol/l ou 0,13 mol/l, ou à 3,2 % ou 3,8 %) pour les prélèvements sanguins
Eau distillée ou désionisée sans conservateurs
Therapeutische Bereiche Tubes en plastique
Die therapeutischen Bereiche für die INR können in Abhängigkeit von der jeweiligen Indikation einer Pipettes en plastique pour le transfert des échantillons
oralen Antikoagulanzientherapie variieren10. Pipettes pour la mesure exacte de 20,0 ml, 10,0 ml, 1,0 ml, 0,50 ml, 0,20 ml et 0,10 ml
Leistungsmerkmale des Tests Appareil de coagulation
Präzision Appareils
Die Präzision von Thromboplastinzeit-Werten ist im allgemeinen von der verwendeten Methode Le réactif Dade® Innovin® peut être utilisé manuellement ou sur des appareils automatiques de coagulation.
abhängig. Mit Reagenzien einer Charge sollten Ergebnisse erzielt werden, die innerhalb der Siemens Healthcare Diagnostics propose des manuels de référence (protocoles d’adaptation) pour différents
Qualitätskontrollgrenzen des Labors reproduzierbar sind. appareils de coagulation. Ces manuels contiennent des informations sur la réalisation des tests et leurs ca-
Die Präzision von Dade® Innovin® Reagenz am Sysmex® CA-6000 System wurde mit ractéristiques, spécifiques aux tests et à l’appareil. Ces informations peuvent différer de celles indiquées dans
Qualitätskontrollmaterial bei insgesamt 6 Testläufen an 3 Tagen (2 Testungen pro Tag) und 4-fach cette notice d’emploi. Dans ce cas, utiliser les données du manuel de référence (protocoles d’adaptation) et
Bestimmungen pro Kontrolle bestimmt. Pro Testung wurden die folgenden Ergebnisse erzielt: non celles de cette notice d’emploi. Respecter les instructions d’emploi du fabricant de l’appareil !

Variationskoeffizient
Prélèvement et préparation des échantillons à tester
Bestimmung Kontrolle n Mittelwert Mélanger neuf parts de sang de patient fraîchement prélevé avec une part de solution de citrate de so-
Intra-Assay Inter-Assay Gesamt dium à 0,11 ou 0,13 mol/l (3,2 % ou 3,8 %). Il est possible d’utiliser un système de tubes de prélèvement
Thromboplastinzeit 1 24 12,4 s 1,3 % 2,0 % 2,4 % ou une seringue.
2 24 33,0 s 0,7 % 3,4 % 3,5 % Centrifuger l’échantillon sanguin à 1500 x g pendant au moins 15 minutes à température ambiante.
abgeleitetes 1 24 2,37 g/l 4,0 % 2,8 % 4,9 % Conserver à température ambiante dans le tube fermé. Ne pas conserver sur de la glace ni entre + 2
à + 8 °C car l’activation du facteur VII par le froid peut fausser les résultats. Le plasma doit être testé
Fibrinogen 2 24 3,37 g/l 4,1 % 3,0 % 5,1 % dans les 24 heures suivant le prélèvement sanguin. Ne pas conserver les échantillons à + 37 °C
Literatur pendant plus de 5 minutes. Si le patient suit un traitement anticoagulant par héparine et coumarine,
les résultats peuvent varier en fonction de la durée de conservation.
Siehe englische Gebrauchsanweisung. Consulter le document CLSI H21-A55 pour connaître le détail de la préparation et de la conservation
* nicht in den USA erhältlich des échantillons.
** Die mittlere normale TPZ oder MNPT (= Mean Normal Pathrombin Time) ist definiert als Mittelwert
des Normalbereichs. Sie muss speziell für jede Thromboplastincharge mit der für die Analyse Réalisation du test
von Patientenproben verwendeten Methode bzw. dem dafür eingesetzten Gerinnungsmessgerät Réalisation manuelle :
bestimmt werden. Préchauffer le réactif Dade® Innovin® à +37 °C.
Ci-Trol, Dade und Innovin sind Warenzeichen von Siemens Healthcare Diagnostics. Distribuer dans des tubes à essai en plastique selon le protocole suivant :
Sysmex ist ein eingetragenes Warenzeichen von SYSMEX CORPORATION.
Echantillon à tester Contrôle
Mit dem Erwerb des durch die U.S. Patente Nr. 5,625,036, 7,084,251 und 7,049,131 geschützten Dade® Plasma 0,1 ml -
Innovin® erhält der Käufer das eingeschränkte Recht, dieses Produkt gemäß dieser Gebrauchsanweisung
Contrôle - 0,1 ml
zu verwenden.
Laisser incuber les échantillons dans des tubes pendant 1
à 2 minutes (max. 5 minutes) à +37 °C.
Ajouter rapidement le réactif Dade® Innovin® préchauffé 0,2 ml 0,2 ml
Déclencher le chronomètre au moment de l’addition du réactif Dade® Innovin®, et mesurer le temps qui
Ausgabe Mai 2008 s’écoule jusqu’à la formation du caillot.
Contrôle de qualité interne

Dade Innovin ® ® Domaine normal : Dade® Ci-Trol® Niveau 1 ou Plasma de contrôle N


Domaine thérapeutique : Dade® Ci-Trol® Niveau 2, Dade® Ci-Trol® Niveau 3 ou Plasma de contrôle P
A chaque changement de flacon de réactif, au début de chaque test, après chaque calibration et au
moins toutes les 8 heures sur une même journée de travail, tester deux contrôles (un dans le domaine
Domaine d’utilisation normal et un dans le domaine thérapeutique).
Pour la mesure du Temps de Quick (TQ - ou Temps de Thromboplastine, TP), ainsi que les autres tests Traiter les contrôles comme des échantillons de patients.
basés sur cette mesure, dans le plasma citraté humain. Chaque laboratoire doit déterminer son propre domaine de confiance pour les contrôles. Définir un
nouveau domaine à chaque changement de lot de réactif ou de contrôle. Le domaine de confiance cor-
Intérêt diagnostique respond généralement à ± 2,5 déviation standard (DS) par rapport à la valeur moyenne du contrôle.
Le réactif Dade® Innovin® est un facteur tissulaire humain recombinant purifié, préparé à partir d’E. Coli, Si les valeurs des contrôles sortent du domaine de confiance, vérifier l’appareil de coagulation, les
et additionné de phospholipides synthétiques (thromboplastine)1, de calcium, de tampon et de stabilisa- contrôles ainsi que les réactifs. Ne pas valider les valeurs obtenues pour l'échantillon de patient tant que
teurs. Le réactif induit la formation d’un caillot par les voies d’activation exogène et commune selon un l’origine d’une valeur aberrante n’a pas été identifiée et corrigée.
test de dépistage global, la mesure du Temps de Quick (TQ). Le réactif Dade® Innovin® a trois principales
indications basées sur le TQ2 : Exploitation des résultats
1. comme test de dépistage rapide, en vue de mettre en évidence un ou plusieurs déficits du système Le rendu des résultats de TQ se fait selon différentes méthodes. Pour le réactif Dade® Innovin®, il est
exogène de la coagulation, témoins de troubles de la coagulation congénitaux ou acquis, de maladies donné une valeur ISI («International Sensitivity Index»), qui varie selon les lots et les appareils, et qui
hépatiques ou d’un déficit en vitamine K; permet de rendre les résultats des patients en INR («International Normalized Ratio»)4. Pour le calcul et
2. comme test sensible permettant un suivi des traitements aux anticoagulants oraux, et l’utilisation des valeurs INR, cf. ci-dessous. Il est recommandé d’utiliser des INR pour la documentation
3. pour le dosage des facteurs exogènes de la coagulation. des résultats obtenus chez les patients sous anticoagulants oraux. Comme alternative, on peut égale-
ment rendre les résultats de patients sous forme de TQ (en secondes), accompagnés du domaine de
Différents appareils de coagulation photo-optiques permettent en plus d’obtenir la valeur du fibrinogène référence (en secondes).
dérivé pendant la mesure du temps de Quick.
Exemple : résultat du patient : 18 secondes ; domaine de référence : 9,7 - 12,3 secondes.
Le réactif Dade® Innovin® est préparé à partir de facteur tissulaire humain recombinant et de phospho-
lipides synthétiques, qui ne contiennent aucun des autres facteurs de la coagulation, comme par ex. la Détermination de l’INR (International Normalized Ratio)
prothrombine, le F VII ou le F X. Ceci explique sa grande sensibilité aux plasmas exempts de facteurs Valeurs pour Dade® Innovin® Réactif
de la coagulation ainsi qu’aux plasmas de patients sous anticoagulants oraux. La sensibilité du réactif Standardisation internationale du TQ (Temps de Quick) pour le suivi des traitements aux anticoagulants oraux
Dade® Innovin® est très proche de celle de la thromboplastine de référence de l’OMS, obtenue à partir 1. Selon les recommandations générales de l’Organisation Mondiale de la Santé (OMS)4 et du Comité
de cerveau humain3. De plus, le réactif Dade® Innovin® est insensible aux concentrations thérapeutiques International pour la Thrombose et l’Hémostase, les valeurs de TQ pour les patients sous anticoagu-
d’héparine. Du fait de sa grande sensibilité aux facteurs de la coagulation et de son absence de sensibi- lants oraux devraient être rendus en INR. Les INR sont indépendants des réactifs et des méthodes
lité à l’héparine dans le domaine thérapeutique, le réactif Dade® Innovin® est particulièrement adapté à utilisés, et particulièrement adaptés au rendu des résultats de patients stabilisés par un traitement
la surveillance des traitements aux anticoagulants oraux3. Sa grande sensibilité, c’est-à-dire sa capacité aux anticoagulants oraux à long terme.
à réagir à des activités de facteurs de la coagulation faiblement diminuées, permet même de révéler des L’INR est calculé selon la formule suivante4 :
plasmas qui ne sont que faiblement pathologiques.
TQ du patient
INR = RISI, sachant que R = —————————————
MNPT**

B4212 G40 E0501 (837) 3


Dade® Innovin®
ISI est l’index de sensibilité international pour la combinaison réactif/appareil.
Les valeurs ISI pour les réactifs de thromboplastine de Siemens sont déterminées selon les recom-
mandations de l’OMS.
2. Méthodes pour le calcul de l’INR : Settore d'impiego
a. à l’aide d’une calculatrice avec fonction exponentielle : Da utilizzare per le determinazioni del tempo di protrombina (PT) e per i dosaggi basati sul tempo di
Ces indications sont spécialement prévues pour la calculatrice TI-55 II de Texas Instruments. protrombina su plasma umano citratato.
Avec d’autres calculatrices, comme les Hewlett-Packard, la saisie peut varier. Se reporter aux
instructions de la calculatrice utilisée. Tester les exemples de calcul à l’aide de la table de conver- Significato diagnostico
sion, afin de détecter les erreurs de calcul. Il Reagente Dade® Innovin® viene preparato da fattore tissutale umano ricombinante purificato prodotto
Entrer le TQ du patient en secondes et appuyer sur « ÷ ». Entrer ensuite le MNPT**, puis appuyer in E. coli, con aggiunta di fosfolipidi sintetici (tromboplastina)1, calcio, tamponi e stabilizzanti. Il reagente
sur « = ». L’écran affiche R, le ratio du patient. Appuyer ensuite sur la touche « yx », entrer la avvia la coagulazione attraverso le vie intrinseca e comune in un test di screening globale, il tempo di
valeur ISI spécifique de la combinaison thromboplastine/appareil utilisée, et appuyer sur « = ». Le protrombina (PT). Il Reagente Dade® Innovin® ha tre principali applicazioni basate sul PT2:
résultat affiché est l’INR de l’échantillon de patient. 1. come test di screening rapido per rilevare carenze singole o combinate del sistema estrinseco della
Saisie Signification coagulazione, indicative di disordini ereditari e acquisiti della coagulazione, patologie epatiche o
Exemple: 24 TQ patient carenza di vitamina K;
÷ divisé par 2. come test di monitoraggio sensibile per la terapia anticoagulante orale; e
11,0 MNPT** 3. come dosaggio per specifici fattori della coagulazione.
= ratio du patient (affichage à l’écran : 2,1818) Inoltre, numerosi analizzatori per coagulazione fotoottici sono in grado di derivare il valore del fibrinogeno
yx touche de fonction exponentielle dalla determinazione del tempo di protrombina.
1,1 exemple de valeur ISI Il Reagente Dade® Innovin® viene prodotto utilizzando fattore tissutale umano ricombinante e fosfolipidi
= résultat : INR (affichage à l’écran : 2,3588) sintetici che non contengono nessun altro fattore della coagulazione come protrombina, F VII e F X. Per-
tanto, è altamente sensibile alle carenze di fattori e ai campioni di pazienti trattati con anticoagulanti orali.
Rendre un INR de 2,4 La sensibilità del Reagente Dade® Innovin® è molto simile alla tromboplastina3 di riferimento da cervello
b. à l’aide du tableau de conversion : umano dell’OMS. Il Reagente Dade® Innovin® non è sensibile all’eparina a livelli terapeutici. L’elevata
calculer d’abord le ratio R de TQ, en divisant le TQ du patient par le MNPT**. L’INR correspond à sensibilità del Reagente Dade® Innovin® ai fattori della coagulazione e la sua insensibilità all’eparina a
la valeur qui se trouve dans la table de conversion jointe, à l’intersection de la colonne des valeurs dosi terapeutiche lo rendono adatto per il monitoraggio della terapia anticoagulante orale3. Inoltre, la sua
ISI et de la ligne des ratios des TQ patients (R). elevata sensibilità (la reattività del reagente a diminuzione moderata dell’attività dei fattori) consente la
c. par méthode automatique : differenziazione dei plasmi anormale, anche nell’intervallo moderatamente patologico.
Les INR sont calculés automatiquement par différents appareils de coagulation. Se reporter au
manuel d’utilisation de l’automate utilisé. Des protocoles spécifiques sont envoyés sur demande Principio del Metodo
par Siemens. La cascata coagulativa viene attivata incubando il plasma con la quantità ottimale di tromboplastina e
calcio; viene poi misurato il tempo di coagulazione.
Valeurs de fibrinogène dérivé
En utilisant le réactif Dade® Innovin® et un test approprié sur un appareil de coagulation photo-optique Reagenti
Siemens ou Sysmex®, on peut également obtenir avec ce réactif la concentration de fibrinogène par
Contenuto della confezione
analyse de la modification du signal optique pendant la mesure du Temps de Quick. Pour cela, utiliser
comme courbe d’étalonnage la courbe-mère indiquée pour le fibrinogène dérivé dans le tableau des 10 x l 4 mL, [REF] B4212-40
valeurs spécifiques à chaque lot.
10 x l 10 mL, [REF] B4212-50
Limites du test 12 x l 20 mL, [REF] B4212-100
Le facteur tissulaire humain recombinant ne contenant pas d’autres facteurs de la coagulation, on peut, Composizione
lors du dosage des facteurs exogènes, obtenir avec le réactif Dade® Innovin® des temps de coagulation
plus allongés qu’avec d’autres réactifs à la plus faible activité du facteur déficient. C’est ainsi que le Reagente Dade® Innovin®: Reagente liofilizzato composto da fattore tissutale umano ricombinante e
temps de coagulation pour l’activité la plus faible peut être supérieure à 100 secondes. fosfolipidi sintetici (tromboplastina), ioni calcio, un componente neutralizzante l’eparina, tamponi e sta-
bilizzanti (sieroalbumina bovina).
Siemens a validé l’utilisation de ces réactifs sur plusieurs analyseurs afin d’optimiser les performances
du produit et répondre à ses spécifications. Les modifications apportées par l’utilisateur ne sont pas sous Avvertenze e precauzioni
la responsabilité de Siemens dans la mesure où elles peuvent affecter les performances du système Per uso diagnostico in-vitro.
et les résultats des dosages. Il est de la responsabilité de l’utilisateur de valider toutes modifications Preparazione dei Reagenti
apportées à ces instructions ou à l’utilisation des réactifs sur les analyseurs autres que ceux mentionnés
dans les protocoles d’application Siemens ou dans la présente notice d’utilisation. Ricostituire un flacone di Reagente Dade® Innovin® con acqua distillata o deionizzata utilizzando il volu-
Les résultats de ce test doivent toujours être interprétés en rapport avec les antécédents médicaux du me indicato sull’etichetta del flacone. Conservare da +2 a +8 °C.
patient, les signes cliniques et autres constatations. Per garantire la completa ricostituzione, mescolare bene il contenuto del flacone immediatamente dopo
aver aggiunto l’acqua. Se lasciato a riposo, il Reagente Dade® Innovin® dovrebbe essere rimescolato
Facteurs d’interférence prima dell’uso per assicurare l’omogeneità della soluzione. Non occorre la miscelazione continua.
Le Temps de Quick peut être influencé par un grand nombre de médicaments fréquemment prescrits4, Nota: Non utilizzare acqua contenente conservanti.
phénomène dont il faut tenir compte, surtout lorsqu’on obtient des valeurs anormales inattendues. Dans
ce cas-là, en chercher la cause en effectuant d’autres tests de coagulation. Conservazione e Stabilità
La turbidité des échantillons lipémiques, par ex. en cas d’alimentation artificielle, peut avoir une influence Conservare da +2 a +8 °C. A questa temperatura, il reagente non aperto può essere utilizzato fino alla
sur la détermination du fibrinogène dérivé. data di scadenza (vedere etichetta del flacone).
Le réactif Dade® Innovin® est insensible aux concentrations d’héparine non fractionnée, jusqu’à 2,0 uni- Stabilità dopo ricostituzione: da +2 a +8 °C 10 giorni (flacone chiuso)
tés/ml. L’étude de sensibilité à l’héparine a été effectuée sur un pool de plasmas normaux enrichi. La da +15 a +25 °C 5 giorni (flacone chiuso)
sensibilité à l’héparine se définit par le concentration d’héparine entraînant un allongement du temps a +37 °C 24 ore (flacone chiuso)
au-delà du domaine de référence. Le informazioni sulla stabilità on-board per i diversi analizzatori per coagulazione sono indicate nelle
Les inhibiteurs tels que les lupus anticoagulants peuvent interférer avec le taux de prothrombine et Reference Guides (Protocolli Applicativi).
donner lieu par exemple à des INR qui ne reflètent pas le niveau exact d'anticoagulant6. Non congelare!
Des doses thérapeutiques d’Hirudin ou d’un autre inhibiteur direct de la thrombine entraînent un allon- Indici di scadenza: Assenza di vuoto all’apertura del flacone; difficoltà di ricostituzione del reagente;
gement des temps de coagulation7,8. risultati non riproducibili.
Domaines de référence Materiali necessario ma non fornito
Les valeurs obtenues sur des sujets sains varient d’un laboratoire à l’autre selon la méthode utilisée. Control Plasma N oppure Dade® Ci-Trol® Level 1
Aussi chaque laboratoire doit-il déterminer ses propres domaines de référence en se basant sur la Control Plasma P, Dade® Ci-Trol® Level 2 oppure Dade® Ci-Trol® Level 3
technique et l’appareil de coagulation qu’il utilise. PT-Multi Calibrator* (per maggiori informazioni sull’uso, consultare le Istruzioni d'uso)
Une étude portant sur des sujets apparemment sains (n = 138) a déterminé les domaines de référence Standard Human Plasma oppure plasma normale fresco4 per determinare il PT medio normale
suivants (5ème - 95ème percentiles) : (MNPT)**
Système Sysmex® CA-7000 : domaine de référence central de 90 % : 10,4 - 12,4 secondes Soluzione di sodio citrato (0,11 mol/L oppure 0,13 mol/L / 3,2 % oppure 3,8 %) per il prelievo del san-
Fibrinogène dérivé9 : 1,8 - 3,5 g/l gue
Acqua distillata o deionizzata senza conservanti
Domaines thérapeutiques Provette di plastica
Les domaines thérapeutiques pour l’INR peuvent varier selon l’indication des traitements aux anticoa- Pipette di plastica
gulants oraux10. Pipette di precisione da 20,0 mL, 10,0 mL, 1,0 mL, 0,50 mL, 0,20 mL e 0,10 mL
Caractéristiques du test Analizzatore per coagulazione
Précision Strumentazione
La précision des valeurs de Temps de Quick dépend généralement de la méthode utilisée. En utilisant Il Reagente Dade® Innovin® può essere utilizzato manualmente oppure su analizzatori automatici per
des réactifs d’un même lot, on doit obtenir des résultats qui sont reproductibles à l’intérieur du domaine coagulazione. Siemens Healthcare Diagnostics offre le Reference Guides (Protocolli Applicativi) per
de contrôle de qualité défini par le laboratoire. numerosi analizzatori per coagulazione. Le Reference Guides (Protocolli Applicativi) riportano utilizzo
La précision du réactif Dade® Innovin® sur le système Sysmex® CA-6000 a été déterminée à l’aide de specifico analizzatore/test e informazioni sulle caratteristiche che possono differire da quelli forniti nelle
préparations de contrôle de qualité, testés en 6 séries au total sur 3 jours (2 tests par jour), chaque presenti Istruzioni per l’Uso. In questo caso, l’informazione contenuta nelle Reference Guides (Protocolli
contrôle étant testé 4 fois. Les résultats suivants ont été obtenus : Applicativi) sostituisce le informazioni delle presenti Istruzioni per l’Uso. Consultare il manuale di istru-
zioni del produttore dello strumento!
Coefficient de variation
Dosage Contrôle n Valeur moyenne répétabilité reproductibilité total
Raccolta e preparazione dei campioni
Mescolare 9 parti di sangue fresco del paziente con 1 parte di soluzione di citrato di sodio da 0,11 o
Temps de Quick 1 24 12,4 s 1,3 % 2,0 % 2,4 % 0,13 mol/L (3,2 % o 3,8 %). È possibile utilizzare un sistema con provetta sottovuoto o una siringa.
2 24 33,0 s 0,7 % 3,4 % 3,5 % Centrifugare il campione di sangue a 1500 x g per almeno 15 minuti a temperatura ambiente.
Fibrinogène dérivé 1 24 2,37 g/l 4,0 % 2,8 % 4,9 % Conservare in una provetta chiusa a temperatura ambiente. Non conservare in ghiaccio oppure a
2 24 3,37 g/l 4,1 % 3,0 % 5,1 % temperature tra +2 e +8 °C poiché l'attivazione del fattore VII dovuta al freddo può alterare i risultati.
Testare il plasma entro 24 ore dalla raccolta del campione. I campioni non devono restare a una
Littérature temperatura di +37 °C per più di 5 minuti. Se il paziente sta seguendo una terapia sia con eparina che
Cf. notice d’emploi en anglais. anticoagulante cumarinico, i risultati potrebbero variare in funzione del tempo di conservazione.
* non disponible aux USA Per maggiori informazioni sulla preparazione e conservazione del campione, consultare il documento
CLSI H21-A55.
** Le MNPT (= Mean Normal Prothrombin Time) est défini comme la valeur moyenne du domaine
normal. Il doit être spécialement déterminé pour chaque lot de thromboplastine, selon la méthode ou
l’appareil de coagulation utilisé pour l’analyse des échantillons de patients.
Ci-Trol, Dade et Innovin sont des marques commerciales de Siemens Healthcare Diagnostics.
Sysmex est une marque commerciale de SYSMEX CORPORATION.
Dade® Innovin® est protégé par les brevets américains n° 5,625,036, 7,084,251 et 7,049,131. En ache-
tant Dade® Innovin®, l’acquéreur obtient une licence d’utilisation limitée lui donnant le droit d’utiliser le kit
Dade® Innovin® acheté conformément à cette notice d’utilisation.

Edition Mai 2008

B4212 G40 E0501 (837)

B4212 G40 E0501 (837) 4


Esecuzione del test In uno studio su soggetti visibilmente sani (n = 138), è stato determinato il seguente intervallo di riferi-
mento (dal 5° al 95° percentile):
Esecuzione Manuale:
SIstema Sysmex® CA-7000: Intervallo di riferimento centrale al 90 %: da 10,4 a 12,4 secondi
Preriscaldare il Reagente Dade® Innovin® a +37 °C. Fibrinogeno Derivato9: 1,8 - 3,5 g/L
Pipettare in provette da coagulazione come segue:
Intervalli Terapeutici
Campione in esame Controllo Gli intervalli terapeutici per l’INR possono variare secondo l’indicazione della terapia anticoagulante orale10.
Plasma 0,1 mL - Caratteristiche del test
Controllo - 0,1 mL
Precisione
Incubare provette e campioni per 1 - 2 minuti (max. 5 minuti)
a +37 °C La precisione dei risultati del tempo di protrombina è generalmente limitata dal metodo usato. Pertanto,
su un lotto singolo, il reagente dovrebbe dare risultati che siano riproducibili nell’ambito del controllo di
Aggiungere Reagente Dade® Innovin® preriscaldato 0,2 mL 0,2 mL qualità del laboratorio.
Avviare il cronometro simultaneamente all’aggiunta del Reagente Dade® Innovin®. Rilevare il tempo di La precisione del Reagente Dade® Innovin® sul sistema Sysmex® CA-6000 è stata valutata con materiale
formazione del coagulo. di controllo di qualità su un totale di sei (6) cicli operativi separati nell’arco di tre (3) giorni di lavoro (due
cicli al giorno) e con 4 replicati per ogni livello di controllo per ciclo, con i seguenti risultati:
Controllo di Qualità Interno
Intervallo normale: Dade® Ci-Trol® Level 1 oppure Control Plasma N Coefficiente di Variazione
Intervallo patologico: Dade® Ci-Trol® Level 2, Dade® Ci-Trol® Level 3 or Control Plasma P Test Livello di Controllo n Media Nel Ciclo Tra Cicli Totale
Due livelli di materiale di controllo di qualità (intervallo normale e patologico) devono essere analizzati
all’avvio di ogni ciclo operativo, con ogni calibrazione, al cambio del flacone di reagente e almeno ogni Tempo di Protrombina 1 24 12,4 s 1,3 % 2,0 % 2,4 %
otto ore per ogni giorno di lavoro. 2 24 33,0 s 0,7 % 3,4 % 3,5 %
Il materiale di controllo deve essere preparato e analizzato allo stesso modo dei campioni. Fibrinogeno Derivato 1 24 2,37 g/L 4,0 % 2,8 % 4,9 %
Ogni laboratorio dovrebbe definire un intervallo di variazione accettabile per i controlli. Nuovi intervalli di 2 24 3,37 g/L 4,1 % 3,0 % 5,1 %
controllo dovrebbero essere definiti per ogni lotto di reagente o di materiale di controllo. Tale intervallo è
generalmente basato su ± 2,5 deviazioni standard (DS) dal valore medio del controllo.
Se i valori di controllo sono al di fuori dell’intervallo di accettabilità, controllare l’analizzatore per coa- Bibliografia
gulazione, i controlli ed i reagenti. Non refertare i risultati dei pazienti finché non sia stata individuata e
corretta la causa di tale deviazione. Vedi testo inglese.
* Non disponibile negli USA
Calcolo dei risultati
** Il PT normale medio viene definito come il valore medio dell’intervallo normale. Deve essere determi-
Attualmente, vari metodi sono utilizzati per refertare i risultati PT. I valori di ISI (International Sensitivity nato specificamente per ogni lotto di tromboplastina utilizzando il metodo impiegato per analizzare i
Index) per il Reagente Dade® Innovin® vengono forniti per la specifica combinazione reagente/strumento; campioni dei pazienti e, se necessario, con il coagulometro utilizzato per le analisi.
questo permette di refertare i risultati in INR (International Normalized Ratio)4. Calcolo e utilizzo dell’INR Ci-Trol, Dade e Innovin sono marchi di Siemens Healthcare Diagnostics.
sono descritti di seguito. Il sistema INR è il metodo preferenziale per refertare i risultati dei campioni di
pazienti in terapia anticoagulante orale. In alternativa, è possibile utilizzare il PT dei pazienti (in secondi) Sysmex è un marchio di SYSMEX CORPORATION.
insieme con l’intervallo di riferimento (in secondi) per refertare i risultati. L’acquisto di Dade® Innovin® comprende una licenza limitata per l’acquirente per l’uso del prodotto Dade®
Esempio: risultato del paziente 18 secondi; intervallo di riferimento 9,7 - 12,3 secondi. Innovin® coperto da brevetto statunitense n. 5,625,036, 7,084,251 e 7,049,131 in conformità alle Istruzio-
ni per l’uso indicate nel presente documento.
Determinazione dell’INR (International Normalized Ratio)
Valori utilizzando il Reagente Dade® Innovin®
Standardizzazione Internazionale del PT (Tempo di Protrombina) per il Monitoraggio della Terapia An-
ticoagulante Orale
1. Secondo le raccomandazioni congiunte dell’Organizzazione Mondiale della Sanità (OMS)4 e del- Edizione Maggio 2008
l’International Committee on Thrombosis and Haemostasis, i risultati del PT per pazienti in terapia
anticoagulante orale dovrebbero essere refertati come valori INR. I risultati refertati in INR sono

Dade® Innovin®
indipendenti dai reagenti e dai metodi utilizzati, e sono specificamente destinati a valutare pazienti
stabilizzati in terapia anticoagulante orale a lungo termine.
L’INR viene determinato4 in base alla seguente formula:
PT Paziente
INR = RISI, dove R = ——————————— Campos de aplicación
PT medio normale** Para la determinación, en plasmas humanos citratados, del tiempo de protrombina (TP) y para los test
basados en éste.
ISI è l’International Sensitivity Index della combinazione reagente/strumento.
I valori di ISI per le tromboplastine Siemens vengono determinati secondo le raccomandazioni del- Significado diagnóstico
l’OMS. El reactivo Dade® Innovin® es un factor tisular humano recombinante producido en E. Coli, purificado,
2. Metodi di calcolo dell’INR: combinado con fosfolípidos sintéticos (tromboplastina)1, calcio, tampón y estabilizadores. El reactivo
a. Calcolatori con funzioni esponenziali: induce la formación del coagulo sobre las vías de activaciòn exógenas y el tramo final común en un test
Queste istruzioni si riferiscono specificamente al calcolatore Texas Instruments TI-55 II. Altri cal- de chequeo global, la determinación del tiempo de protrombina (TP). El reactivo Dade® Innovin® se utiliza
colatori, es. i modelli Hewlett-Packard, possono richiedere sequenze diverse di impiego dei tasti. en tres de las principales aplicaciones basadas en el TP2:
Consultare il manuale del calcolatore e verificare gli esempi rispetto alla Tabella di Conversione 1. como test de chequeo rápido para el reconocimiento de deficiencias aisladas o combinadas en los
per garantire l’adeguatezza delle procedure di conversione. mecanismos extrínsecos de la coagulación, mediante los cuales se pueden reconocer alteraciones
Digitare il PT del paziente in secondi, premere ”÷”, digitare lo MNPT**, premere ”=”. Il display de la coagulación heredadas o adquiridas, enfermedades del hígado o deficiencias de vitamina K;
mostra ora R, il Rapporto Paziente. Premere ora il tasto ”yx”, quindi digitare il valore di ISI specifico 2. como test sensible para monitorizar las terapias con anticoagulantes orales y
della combinazione tromboplastina/strumento in uso e premere ”=”. Il risultato indicato è il valore 3. para la determinación de los factores exógenos de la coagulación.
di INR del paziente. Adicionalmente, diversos analizadores de coagulación foto-ópticos pueden proporcionar el valor del
Premere Note Fibrinógeno derivado a partir de la determinación del Tiempo de Protrombina
Esempio: 24 PT paziente El reactivo Dade® Innovin® se prepara a partir de factor tisular humano recombinante y fosfolípidos sinté-
÷ diviso per ticos, que no contienen ninguno de los otros factores de la coagulación como por ej., protrombina, FVII
11,0 MNPT** y FX. Por esta razón es de gran sensibilidad contra plasmas deficientes en factores de la coagulación
= rapporto paziente (il display mostra 2,1818) y plasmas de pacientes bajo una terapia con anticoagulantes orales. La sensibilidad del reactivo Dade®
Innovin® es muy similar a la de la tromboplastina de referencia de la OMS obtenida de cerebro humano3.
yx tasto della funzione esponenziale
Además, el reactivo Dade® Innovin® es insensible a las concentraciones terapéuticas de heparina. De-
1,1 esempio valore ISI bido a su alta sensibilidad contra los factores de la coagulación y a su insensibilidad contra la heparina
= risultato: INR (il display mostra 2,3588) en rangos terapéuticos, el reactivo Dade® Innovin® es especialmente apropiado para el control de las
Refertare come INR = 2,4 terapias con anticoagulantes orales3. Debido a su alta sensibilidad (esto es, la reacción del reactivo a la
b. Tabella di Conversione: actividad moderadamente baja de los factores de la coagulación) se pueden reconocer incluso muestras
Prima, calcolare il rapporto PT paziente/MNPT**, R. Il valore INR può poi essere letto nell’allegata de plasmas levemente patológicas.
Tabella di Conversione INR guardando nella colonna dell’adeguato valore di ISI, alla riga corri-
spondente al rapporto del PT paziente (R). Principio del método
c. Automatico: Mediante la incubación del plasma con las cantidades optimas de tromboplastina y calcio se desencade-
I valori INR possono essere calcolati automaticamente da numerosi coagulometri. Per i dettagli, na el proceso de coagulación. Se mide el tiempo gastado hasta la formación del coagulo.
consultare il relativo manuale di istruzioni. I protocolli per analizzatori per coagulazione specifici Reactivos
sono disponibili a richiesta presso Siemens.
Contenido del envase comercial
Fibrinogeno Derivato
Utilizzando il Reagente Dade® Innovin® e l’adeguato test sugli analizzatori fotometrici per coagulazio- 10 x l 4 ml, [REF] B4212-40
ne Siemens oppure sugli analizzatori per coagulazione Sysmex®, la concentrazione di fibrinogeno può 10 x l 10 ml, [REF] B4212-50
essere derivata analizzando la variazione del segnale ottico durante le determinazioni del tempo di
protrombina, utilizzando una curva di calibrazione per il fibrinogeno derivato. Tale curva di calibrazione 12 x l 20 ml, [REF] B4212-100
(master curve) viene fornita da Siemens nella tabella lotto-dipendente dei valori dichiarati. Composición
Limitazioni della esecuzione del test Reactivo Dade® Innovin®: Liofilizado de factor tisular humano recombinado y fosfolípidos sintéticos
(Tromboplastina), iones de calcio, una unión neutralizante de heparina, tampón y estabilizadores (al-
Il fattore tissutale umano ricombinante non contiene altri fattori della coagulazione. Le curve di dosaggio búmina de suero bovino).
dei fattori utilizzando il Reagente Dade® Innovin® possono pertanto mostrare tempi di coagulazione più
lunghi ai più bassi livelli di carenza fattoriale rispetto ad altri reagenti. Questo potrebbe tradursi in tempi di Advertencias y medidas de seguridad
coagulazione maggiori di 100 secondi per bassi livelli fattoriali nelle curve di dosaggio dei fattori. Sólo para uso en diagnósticos in-vitro.
Siemens ha validato l’uso di questi reagenti su vari analizzatori per ottimizzare le prestazioni e rispettare Preparación de los reactivos
le specifiche dei prodotti. Le modifiche definite dall’utente non sono supportate da Siemens poiché Disolver un frasco del reactivo Dade® Innovin® liofilizado en la cantidad de agua destilada o desionizada
possono influire sulle prestazioni del sistema e sui risultati del test. Pertanto è responsabilità dell’utente indicada en la etiqueta del frasco. Almacenar entre +2 y +8 °C.
validare tutte le modifiche apportate a queste istruzioni, l’uso dei reagenti su analizzatori diversi da quelli
inclusi nei fogli di istruzioni o nelle istruzioni d’uso fornite da Siemens. Para una completa disolución del contenido del frasco mezclar bien, inmediatamente después de agre-
gar el agua. Si se deja el frasco en reposo, el reactivo Dade® Innovin® se debe mezclar de nuevo bien
I risultati di questo test devono essere sempre interpretati alla luce della anamnesi del paziente, della antes de usar, con el fin de obtener una solución homogénea. No es necesario una agitación continua.
presentazione clinica e valutando contestualmente l’esito di altri accertamenti.
Advertencia: No utilizar agua con agentes de conservación.
Sostanze Interferenti
Estabilidad y almacenaje
Molti farmaci comunemente impiegati possono influenzare i risultati ottenuti dall’analisi del tempo di pro-
trombina4. Questo fatto deve essere tenuto presente quando si ottengano risultati anormali insoliti o Almacenar entre +2 y +8 °C. A esta temperatura y sin abrir, el reactivo permanece estable hasta la fecha
inattesi. Risultati anormali inattesi dovrebbero essere seguiti da ulteriori studi coagulativi per determinare de vencimiento (ver la etiqueta del frasco).
la causa dell’anormalità. Estabilidad después de reconstituido: entre +2 y +8 °C 10 días (frasco cerrado)
La torbidità di campioni lipemici, es. in nutrizione parenterale, può ostacolare l’accuratezza della deter- entre +15 y +25 °C 5 días (frasco cerrado)
minazione del fibrinogeno derivato. a +37 °C 24 horas (frasco cerrado)
Il Reagente Dade® Innovin® è insensibile all’eparina non frazionata fino a concentrazioni di circa 2,0 unità Los datos sobre la estabilidad en el aparato vienen dados en los manuales de referencia (reglamentos
per mL. Lo studio di sensibilità all’eparina è stato condotto utilizzando pool di plasmi normali addizionati de aplicaciòn) de cada uno de los aparatos de medida de la coagulación.
e la sensibilità all’eparina è stata definita dalla concentrazione di eparina nel campione che che ha pro- No congelar!
lungato i risultati del PT oltre il limite superiore dell’intervallo di riferimento. Advertencia sobre deterioro: falta de vacío al abrir el frasco; el reactivo no se deja disolver fácilmente;
Gli inibitori come gli anticoagulanti lupus possono interferire con il tempo di protrombina e produrre ad no se obtienen datos reproducibles.
esempio risultati dell’INR che non riflettono il grado esatto di anticoagulazione6. L’irudina o altri inibitori Materiales adicionales necesarios
direti della trombina a dosi terapeutiche comportano allungamento dei tempi di protrombina7,8.
Plasma control N, o Dade® Ci-Trol® Nivel 1
Valori attesi Plasma control P, Dade® Ci-Trol® Nivel 2 o Dade® Ci-Trol® Nivel 3
I valori per soggetti sani variano da laboratorio a laboratorio secondo la tecnica utilizzata. Quindi, ogni PT-Multi Calibrador* (Para más detalles sobre el uso, consulte las Instrucciones de utilización.)
laboratorio dovrebbe definire i propri intervalli di riferimento in base alla procedura e all’analizzatore per Plasma humano estándard o plasma normal4 fresco para la determinación de MNPT**
coagulazione utilizzati. Solución de citrato de sodio (0,11 mol/l o 0,13 mol/l o bien al 3,2 % o al 3,8 %) para la toma de la
sangre

B4212 G40 E0501 (837) 5


Agua destilada o desionizada sin agentes de conservación reactivos, ya que en el factor tisular humano recombinante no se encuentra ningún otro factor adicional
Tubos de plástico de la coagulación. Por eso, puede ser que para una actividad baja del factor, el tiempo de coagulación
Pipetas de plástico para la trasferencia de las muestras sea de más de 100 segundos.
Pipetas para la medida exacta de 20,0 ml, 10,0 ml, 1,0 ml, 0,50 ml, 0,20 ml y 0,10 ml. Siemens ha validado el uso de los reactivos en varios analizadores para optimizar el rendimiento del
Aparato de medida de la coagulación producto y cumplir con las especificaciones del mismo. Las modificaciones definidas por el usuario no
están garantizadas por Siemens dado que pueden afectar al rendimiento del sistema y a los resultados
Aparatos del ensayo. Es responsabilidad del usuario validar las modificaciones realizadas a estas instrucciones o
El Reactivo Dade® Innovin® se puede utilizar en aparatos de medida de la coagulación manuales o el uso de los reactivos en analizadores distintos a los incluidos en las hojas de aplicaciones de Siemens
automáticos. Siemens Healthcare Diagnostics pone a disposición manuales de referencia (reglamentos o en estas instrucciones de uso.
de aplicación) para diferentes aparatos de medida de la coagulación. Estos contienen información Los resultados de esta prueba deberán interpretarse siempre de acuerdo con la historia clínica del
específica aparato/test para el manejo y el rendimiento, que pueden diferenciarse de la información paciente, la sintomatologia clínica y otras observaciones.
dada en estas instrucciones de manejo. En este caso, la información contenida en los manuales de Factores alterantes
referencia (reglamentos de aplicación) reemplaza la información de estas instrucciones de manejo. Por
favor consulte el manual de instrucciones del fabricante del aparato! El tiempo de protrombina puede ser influenciado por un gran número de medicamentos de prescripción
frecuente4, hecho que se debe tener en cuenta especialmente cuando aparecen valores anormales
Extracción y preparación de la muestra inesperados. Para valores anormales inesperados, se debe buscar la causa, en caso dado, por medio
Mezcle nueve partes de sangre recién extraída con una parte de solución de citrato sódico, 0,11 ó de otros test de la coagulación.
0,13 mol/l (3,2 ó 3,8 %). Puede utilizarse un sistema de tubos con vacío o jeringa. Debido a la turbidez de las muestras lipémicas la exactitud de la determinación del fibrinógeno derivado
La muestra de sangre ha de centrifugarse a 1500 x g durante 15 minutos como mínimo a temperatura puede estar influenciada.
ambiente. El reactivo Dade® Innovin® es insensible a concentraciones de heparina sin fraccionar hasta de 2,0 uni-
Almacenar en un tubo cerrado a temperatura ambiente. No almacene en hielo o refrigerado entre +2 y dades/ml. El estudio de sensibilidad a la heparina se realizo con un pool de plasma normal amplificado.
+8 °C, puesto que la activación del frío puede alterar los resultados del F VII. El plasma debe analizarse La sensibilidad a la heparina se define como la concentración de heparina en la muestra, que conduce
dentro de las 24 horas siguientes a la extracción. Las muestras no deben permanecer a +37 °C más a una prolongación más allá del rango de referencia.
de 5 minutos. Si el paciente está siguiendo una terapia con anticoagulantes basada tanto en heparina Los inhibidores, tales como el anticoagulante lúpico, pueden interferir en el tiempo de protombina y dar
como en cumarina, los resultados pueden variar con el tiempo de almacenamiento. lugar, por ejemplo, a INRs que no reflejen el grado exacto de anticoagulación6.
Consulte el documento H21-A55 del CLSI para obtener información detallada sobre la preparación y el Las dosis terapéuticas de hirudina o de otros inhibidores directos de trombina conducen a tiempos de
almacenamiento de las muestras. coagulación prolongados7,8.

Procedimiento Rangos de referencia


Desarrollo manual: Los valores de personas sanas varían de un laboratorio a otro dependiendo del método utilizado. Cada
laboratorio deberá, por lo tanto, determinar su propio rango de referencia basados en la técnica y los
Precalentar el reactivo Dade® Innovin® a +37 °C. instrumentos utilizados.
Pipetear en un tubo de plástico lo siguiente: En un estudio con personas visiblemente sanas (n = 138) se encontró el siguiente rango de referencia
(5. a 95. percentile):
Muestra del test Control Sistema Sysmex® CA-7000: central 90 % Rango de referencia: 10,4 - 12,4 segundos.
Plasma 0,1 ml - Fibrinógeno derivado9: 1,8 - 3,5 g/l
Control - 0,1 ml Rangos terapéuticos
Incubar las muestras en los tubos plásticos de 1 a 2 minutos Los rangos terapéuticos para el INR pueden variar dependiendo de la indicación utilizada en una tera-
(máximo 5 minutos), a +37 °C péutica con anticoagulantes orales10.
Agregar rápidamente el reactivo Dade® Innovin® precalentado 0,2 ml 0,2 ml
Características del test
Al agregar el reactivo Dade® Innovin® activar inmediatamente el cronómetro. Medir el tiempo necesario
para la formación del coagulo. Precisión
La precisión de los valores de los tiempos de protrombina es, por lo general, dependiente del método
Control de calidad interno utilizado. Con los reactivos de un lote, se deben obtener resultados que sean reproducibles dentro de
Rango normal: Dade® Ci-Trol® Nivel 1 o Plasma control N los límites de control de calidad del laboratorio.
Rango patológico: Dade® Ci-Trol® Nivel 2, Dade® Ci-Trol® Nivel 3 o Plasma control P La precisión del reactivo Dade® Innovin® en el Sysmex® CA-6000 se determinó con material de control de
Los controles se deben usar al comienzo de cada test, para cada cambio de reactivo y por lo menos calidad, para un total de 6 corridas del test, en 3 días (2 ensayos por día) en determinaciones cuadruples
una vez cada 8 horas durante un análisis (uno en el rango normal y uno en el rango patológico). Los por control. Por ensayo se encontraron los siguientes resultados:
controles deben ser tratados igual que las muestras a investigar.
Cada laboratorio deberá estipular sus propios rangos de confianza para los controles. Para cada nuevo
lote de reactivo o de controles se debe definir un nuevo rango de control. Este rango corresponde por Coeficiente de correlación
lo general a ± 2,5 la desviación estándar (DS) del valor promedio de los controles. Determinación Control n Valor promedio Inter assay Intra assay Total
Si los valores de los controles se encuentran por fuera de este rango de confianza, se debe controlar el Tiempo de Protrombina 1 24 12,4 s 1,3 % 2,0 % 2,4 %
aparato de medir la coagulación, así como también, los controles y los reactivos. No valide los resulta- 2 24 33,0 s 0,7 % 3,4 % 3,5 %
dos del paciente hasta haber identificado y corregido la causa de la desviación.
Fibrinógeno derivado 1 24 2,37 g/l 4,0 % 2,8 % 4,9 %
Valoración 2 24 3,37 g/l 4,1 % 3,0 % 5,1 %
Para la presentación de los resultados del TP existen actualmente diferentes métodos. Para el reactivo
Dade® Innovin® existe un valor del „International Sensitivity Index“ (ISI) específico del lote y del aparato,
el cual permite que los resultados de los pacientes se pueden dar como „International Normalized Ratio“
(INR)4. El cálculo y el uso del INR están descritos más adelante. Los datos en INR tienen preferencia Literatura
para la documentación de los resultados de las muestras de pacientes con anticoagulantes orales. Ver boletín informativo en inglés.
Como alternativa para la determinación de los resultados, se puede usar el TP del paciente (en segun- * No se consigue en USA
dos) junto con el rango de referencia (en segundos). ** El TP promedio normal o MNPT ( = Mean Normal Pathrombin Time) está definido como el valor pro-
Ejemplo: Resultado del paciente 18 segundos; Rango de referencia 9,7 - 12,3 segundos. medio del rango normal. Este se debe determinar para cada lote de protrombina usando el método
Determinación del INR (International Normalized Radio) empleado para el análisis de las muestras de pacientes o el aparato de medir la coagulación utilizado
para test.
Valores para el reactivo Dade® Innovin®
Estandarización internacional del TP (tiempo de protrombina) para el monitoreo de terapias con anti- Ci-Trol, Dade y Innovin son marcas comerciales de Siemens Healthcare Diagnostics.
coagulantes orales Sysmex es una marca comercial de SYSMEX CORPORATION.
1. De acuerdo a las recomendaciones comunes de la World Heath Organization (WHO)4 y del Interna-
tional Commitee on Thrombosis and Haemostasis, los valores de TP de pacientes bajo una terapia La adquisición de Dade® Innovin® le otorga al comprador una autorización limitada para utilizar el Dade®
con anticoagulantes orales deben darse en valores INR. Los valores INR son dependientes del Innovin® bajo la Patente EE.UU. N° 5,625,036, 7,084,251 y 7,049,131 de acuerdo con las Instrucciones
reactivo y del método utilizado y especialmente previstos para los resultados de pacientes que hayan de utilización aquí expuestas.
sido estabilizados con una terapia con anticoagulantes orales a largo plazo.
El INR se va a determinar con la siguiente fórmula4:
TP de los pacientes
INR = RISI, donde R = ————————————— Edición Mayo 2008
MNPT**
ISI es el Intenational Sensitivity Index de la combinación Reactivo-/aparato.
El valor ISI para el reactivo de protrombina de Siemens se determina de acuerdo a las recomenda-
ciones de la WHO.
2. Métodos para calcular INR:
Dade® Innovin®
a. Calculadora con función exponencial:
Esta información es valida especialmente para la calculadora TI-55 II de Texas Instrument. Para
Campo de aplicação
otras calculadoras como los modelos de Hewlett-Packard, pueden variar las ordenes. Mayor Para a determinação do tempo de Tromboplastina (TP) e dos testes de plasma humano citratado nele
información se puede encontrar en el manual de operaciones de la calculadora. Compruebe los baseados.
ejemplos de cálculos basado en la Tabla de conversión, para poder reconocer los errores del Significado diagnóstico
cálculo.
O Reagente Dade® Innovin® é um factor de tecido humano purificado e recombinante, produzido em
Dé los valores de TP de los pacientes en segundos y oprima „÷“. Dé ahora los MNPT** y oprima
E.coli, combinado com fosfolípidos sintéticos (Tromboplastina)1, cálcio, tampões e estabilizadores. O
al final „=“. En la pantalla aparece R, el radio del paciente, oprima a continuación la tecla „yx“,
reagente induz a formação de coágulos através dos pathways exógenos e comuns num teste de Scre-
del valor ISI correspondiente a la combinación protrombina-/aparato usado y oprima „=“. El valor
ening global, a determinação do tempo de Tromboplastina (TP)2. O Reagente Dade® Innovin® é usado
mostrado es el valor INR de la muestra del paciente.
em três aplicações:
Orden Comentario
1. Como teste de Screening rápido para detecção das deficiências individuais ou combinadas dos
Ejemplo: 24 TP del paciente mecanismos de coagulação extrínsecos, com o qual podem ser detectadas as perturbações de
÷ dividido por coagulação congénitas ou adquiridas, as doenças hepáticas ou a carência de vitamina K;
11,0 MNPT** 2. Como teste sensível para a monitoração das terapias de anticoagulantes orais e
= radio del paciente(en la pantalla aparece 2,1818) 3. Para a determinação dos factores de coagulação exógenos.
yx tecla para la función exponencial Vários coagulómetros foto-ópticos podem proceder, adicionalmente, à derivação do valor de fibrinogé-
1,1 valor de ISI ejemplo nio durante a determinação do tempo de tromboplastina.
= resultado: INR (en la pantalla aparece 2,3588) O Reagente Dade® Innovin® é produzido a partir de factor de tecido humano recombinante e fosfolípidos
dar el INR como 2,4 sintéticos, que não contêm qualquer outro tipo de factores de coagulação, tais como a Protrombina, FVII
b. Tabla de conversión: e FX. Por isso, é altamente sensível em relação aos plasmas com deficiência de factores de coagulação
Calcule primero el radio TP, R, dividiendo el TP de los pacientes por el MNTP**. El valor del INR e aos plasmas dos pacientes que se encontram sob terapia oral de anticoagulantes. A sensibilidade do
lo encuentra en la Tabla de conversión incluida, en la columna bajo el correspondiente valor de Reagente Dade® Innovin® aproxima-se muito da Tromboplastina de referência da WHO, proveniente do
ISI y en la línea que corresponde al radio TP (R) del paciente. cérebro humano3. Acresce que o Reagente Dade® Innovin® é insensível às concentrações de heparina
terapêuticas. Graças à sua elevada sensibilidade em relação aos factores de coagulação e à insensi-
c. Automático:
bilidade em relação à heparina no campo terapêutico, o Reagente Dade®Innovin® está especialmente
Los valores INR pueden ser calculados automáticamente por muchos aparatos de medida de indicado para a monitoração das terapias orais de anticoagulantes3. Graças à elevada sensibilidade (ou
la coagulación. Más información al respecto se encuentra en los manuales de operación de los seja, a reacção do reagente a uma actividade dos factores de coagulação moderadamente reduzida), é
aparatos. Siemens pone a dispocición protocolos específicos para aparatos de medida de la mesmo possível detectar amostras de plasma com um reduzido grau patológico.
coagulación.
Valor del fibrinógeno derivado Princípio metodológico
Usando un test apropiado junto con aparatos foto ópticos de medida de la coagulación de Siemens A reacção de coagulação é desencadeada pela incubação do plasma com a quantidade optimizada de
o aparatos de medida de la coagulación de Sysmex®, se puede también, con este reactivo, derivar la Tromboplastina e cálcio; o tempo que vai até à formação do coágulo de fibrina é medido.
concentración de fibrinógeno, mediante el análisis de los cambios de la señal óptica durante la determi-
nación del tiempo de tromboplastina. Para esto, se debe usar la curva patrón (Master) para fibrinógeno
derivado, tomada de la Tabla de valores del lote, como curva de calibración.
Limitaciones del procedimiento
Al usar el reactivo Dade® Innovin® para la determinación de los factores exógenos, se puede presentar
para la actividad más baja del factor deficiente tiempos de coagulación mucho más largos que con otros

B4212 G40 E0501 (837) 6


Reagentes Os valores ISI para os reagentes de Tromboplastina da Siemens são determinados de acordo com
as recomendações da WHO.
Conteúdos da embalagens comerciais
2. Métodos para o cálculo do INR:
10 x l 4 ml, [REF] B4212-40 a. Calculadora com função exponencial:
10 x l 10 ml, [REF] B4212-50 Estas indicações aplicam-se, especialmente, à calculadora TI-55 II da Texas Instruments. Nas
outras calculadoras tais como os modelos da Hewlett-Packard, a sequência da introdução pode
12 x l 20 ml, [REF] B4212-100 divergir. As instruções de serviço da calculadora contêm informações. Verifique os exemplos de
Composição cálculo através da tabela de conversão para detectar os erros de conversão.
Reagente Dade® Innovin®: Liofilizado de factor de tecido humano recombinante e fosfolípidos sintéti- Introduza o tempo de TP do paciente em segundos e prima ”÷”. Introduza agora o MNPT** e
cos (Tromboplastina), iões de cálcio, composto neutralizador de heparina, tampões e estabilizadores prima de seguida ”=”. No visor aparece R, o ratio do paciente. Prima agora a tecla „yx“, introduza
(albumina de soro bovino). o valor específico ISI da combinação utilizada de Tromboplastina/Aparelhos e prima ”=”. O resul-
tado apresentado é o valor INR da amostra do paciente.
Advertências e medidas de precaução
Introdução de dados Explicação
Só para uso diagnóstico in-vitro.
Exemplo: 24 tempo de TP
Preparação dos reagentes ÷ dividido por
Diluir um frasquinho de liofilizado de Reagente Dade® Innovin® com água destilada ou desionizada, de 11,0 MNPT**
acordo com a indicação de quantidade do rótulo do frasco. Conservar entre +2 e +8 °C. = ratio do paciente (no visor aparece 2,1818)
Para a diluição total do conteúdo do frasco, misturar bem imediatamente após a adição da água. Se se Tecla yx para a função exponencial
deixar o frasquinho em repouso, o Reagente Dade® Innovin® deverá ser misturado de novo antes da
1,1 Exemplo de valor ISI
utilização, para se obter um solução homogénea. Não é necessário misturar continuadamente.
= resultado: INR (no visor aparece 2,3588)
Nota: Não utilizar água com conservantes.
emitido como INR 2,4
Estabilidade e condições de conservação b. Tabela de conversão:
Conservar entre +2 e +8 °C. Não aberto, o reagente mantém-se estável a esta temperatura até à data Primeiro calcule o ratio R do tempo de TP, dividindo o tempo de TP pelo tempo MNPT**. O valor
de validade (vide o rótulo do frasco). de INR encontra-se na coluna da tabela de conversão por baixo do respectivo valor de ISI e na
Estabilidade após reconstituição: 10 dias entre +2 e +8 °C (frasco fechado) linha que corresponde ao ratio (R) do tempo de TP do paciente.
5 dias entre +15 e +25 °C (frasco fechado) c. Automática:
24 horas a +37 °C (frasco fechado) Os valores de INR podem ser calculados automaticamente por diversos coagulómetros. As infor-
As indicações sobre a estabilidade no aparelho estão mencionadas nos livros de referência (instruções mações a este respeito encontram-se no manual de instruções do aparelho. A pedido, a Siemens
de aplicação) para os diferentes coagulómetros. disponibiliza protocolos específicos para os coagulómetros.
Não congelar! Valor de fibrinogénio derivado
Indício de caducidade: Falta de vácuo ao abrir o frasquinho; só se consegue dissolver o reagente com Se for utilizado um teste adequado juntamente com coagulómetros com medição foto-óptica da Siemens
dificuldade; impossível atingir os valores reprodutíveis. e coagulómetros Sysmex® , com este reagente também se pode proceder à derivação da concentração
Outros materiais necessários de fibrinogénio através da análise da alteração do sinal óptico durante a determinação do tempo de
Plasma de controlo N ou Dade® Ci-Trol® Level 1 Tromboplastina. Para esse efeito, a curva mestra para o fibrinogénio derivado da tabela de valores em
Plasma de controlo P ou Dade® Ci-Trol® Level 2 ou Dade® Ci-Trol® Level 3 função dos lotes, tem de ser introduzida como curva de calibração.
PT-Multi Calibrator* (Consulte as instruções para obter mais informações sobre a utilização.) Limitações à execução do teste
Plasma humano standard ou plasma normal fresco4 para a determinação do MNPT** Ao utilizar o Reagente Dade® Innovin® na determinação dos factores exógenos da actividade ínfima do
Solução de citrato de sódio (0,11 mol/l ou 0,13 mol/l, respectivamente a 3,2 % ou 3,8 %) para a colheita de factor de deficiência, podem produzir-se tempos de coagulação superiores aos dos outros reagentes,
sangue uma vez que o factor de tecido humano recombinante não contém quaisquer outros factores de coa-
Água destilada ou desionizada sem conservantes gulação. Assim, o tempo de coagulação para uma actividade de factor baixa pode ser superior a 100
Tubinhos de plástico segundos.
Pipetas de plástico para a transferência de amostras A Siemens validou a utilização destes reagentes em vários analisadores, com o intuito de optimizar o
Pipetas para a medição exacta de 20,0 ml, 10,0 ml, 1,0 ml, 0,50 ml, 0,20 ml e 0,10 ml desempenho do produto e satisfazer as especificações do produto. As modificações definidas pelo utili-
Coagulómetro zador não são suportadas pela Siemens, na medida em que podem afectar o desempenho do sistema
e os resultados do ensaio. Constitui responsabilidade do utilizador validar as modificações efectuadas
Equipamento nestas instruções ou em relação ao uso dos reagentes noutros analisadores que não os incluídos nas
O reagente Dade® Innovin® pode ser usado manualmente ou em coagulómetros automáticos. A Siemens folhas de instruções de aplicação da Siemens ou nestas instruções de utilização.
Healthcare Diagnostics disponibiliza livros de referência (instruções de aplicação) para os diversos co- Os resultados deste teste devem sempre ser interpretados em conjunto com o histórico médico do
agulómetros. Estes contêm informações específicas dos aparelhos/testes sobre o processamento e doente, estado clínico e outros dados de interesse.
características de performance que podem divergir das informações deste manual de instruções. Neste
caso, as informações dos livros de referência substituem as informações constantes neste manual de Factores de interferência
instruções. Por favor observe o manual de instruções do fabricante do aparelho! O tempo de Tromboplastina pode ser influenciado por uma multiplicidade de medicamentos prescritos
frequentemente4, circunstância essa que deverá ser tomada em consideração, sobretudo quando se ob-
Colheita e preparação de amostras têm valores anormais inesperados. No caso de obtenção de valores anormais inesperados, é necessário
Misturar nove partes de sangue do doente de uma colheita fresca com uma parte de solução de citrato procurar a causa, realizando outros testes de coagulação.
de sódio 0,11 ou 0,13 mol/l (3,2 % ou 3,8 % respectivamente). Poderá utilizar-se um sistema de tubo Devido à turvação das amostras lipémicas, p. ex., em caso de alimentação artificial, a exactidão da
de vácuo ou seringa. determinação do fibrinogénio derivado pode ser afectada.
Centrifugar a amostra de sangue a 1500 x g durante nunca menos de 15 minutos, à temperatura am- O reagente Dade® Innovin® é insensível às concentrações de heparina não fraccionadas até 2,0 unida-
biente. des/ml. O estudo da sensibilidade à heparina foi executado com um pool de plasma normal incremen-
Conservar num tubo não aberto à temperatura ambiente. Não conservar em gelo nem a +2 - +8 °C tado. A sensibilidade à heparina é definida pela concentração da mesma na amostra que ultrapassa o
porque a activação por frio de F VII pode alterar os resultados. O plasma deve ser testado nas 24 horas prolongamento do intervalo de referência.
seguintes à colheita de sangue. As amostras não devem ficar a uma temperatura de +37 °C durante Inibidores como, por exemplo, anticoagulante lúpico podem interferir com o tempo de protrombina e o
mais de 5 minutos. Se o doente estiver a fazer uma terapêutica com anticoagulantes baseados em resultado, por exemplo, em INRs que não reflecte o grau exacto de anticoagulação6.
heparina e cumarina, os resultados podem variar com o tempo de conservação. As doses terapêuticas de hirudina ou outros inibidores directos da Trombina originam tempos de coa-
Consulte o documento CLSI H21-A55 para obter mais informações sobre a preparação e conservação gulação prolongados7,8.
das amostras.
Intervalos de referência
Execução do teste Os valores de indivíduos saudáveis variam de laboratório para laboratório em função do método usado.
Execução manual: Por isso, cada laboratório deverá determinar intervalos de referência próprios, com base no processo
e no coagulómetro usados.
Aquecer, previamente, o reagente Dade® Innovin® a +37 °C.
Num estudo com pessoas saudáveis (n = 138), foi determinado o seguinte intervalo de referência
Pipetar para os tubinhos de plástico da seguinte maneira: (5.- 95. percentil):
Sistema Sysmex® CA-7000: Central 90 % intervalo de referência: 10,4 - 12,4 segundos.
Amostra de ensaio Controlo Fibrinogénio derivado9: 1,8 - 3,5 g/l
Plasma 0,1 ml -
Controlo - 0,1 ml
Intervalos terapêuticos
Os intervalos terapêuticos para o INR podem variar em função da respectiva indicação para uma terapia
Incubar as amostras no tubinho durante 1 a 2 minutos oral de anticoagulantes10.
(5 minutos no máximo) à temperatura de +37 °C .
Adicionar, rapidamente, o reagente Dade® Innovin® 0,2 ml 0,2 ml Características de performance do teste
pré-aquecido Precisão
Ao adicionar o reagente Dade® Innovin® , pôr o cronómetro em marcha para medir o tempo que decorre Geralmente, a precisão dos valores do tempo de Tromboplastina depende do método usado. Com os
até à formação do coágulo. reagentes de um lote podem ser obtidos resultados reproduzíveis dentro dos limites do controlo de
Controlo de qualidade interno qualidade do laboratório.
Intervalo normal: Dade® Ci-Trol® Level 1 ou Plasma de Controlo N A precisão do Reagente Dade® Innovin® no sistema Sysmex® CA-6000 foi determinada com material
Intervalo patológico: Dade® Ci-Trol® Level 2, Dade® Ci-Trol® Level 3 ou Plasma de Controlo P de controlo de qualidade num total de 6 séries de ensaio realizadas durante 3 dias (2 testes por dia) e
determinações quádruplas por controlo. Foram obtidos os seguintes resultados por teste:
A cada mudança dos frascos de reagente, no início da execução do teste, após cada calibração e no mí-
nimo de 8 em 8 horas em cada dia de teste, deverão ser medidos dois controlos (um no intervalo normal
e um no intervalo patológico). O material de controlo deverá ser tratado como as amostras a analisar. Coeficiente de variação
Cada laboratório deverá determinar o seu intervalo de confiança próprio para os controlos. Para cada Determinação Controlo n Valor médio Inter-Assay Intra-Assay Total
lote de reagente ou controlo novos, deverão ser definidos intervalos de controlo novos. Normalmente, Tempo de tromboplastina 1 24 12,4 s 1,3 % 2,0 % 2,4 %
estes apresentam desvios standard (ds) de ± 2,5 em relação ao valor de controlo médio.
2 24 33,0 s 0,7 % 3,4 % 3,5 %
Se os valores de controlo se situarem fora do intervalo de confiança, é necessário controlar o coaguló-
metro, os controlos e os reagentes. Não comunique os resultados do doente até que a causa do desvio Fibrinogénio derivado 1 24 2,37 g/l 4,0 % 2,8 % 4,9 %
tenha sido identificada e corrigida. 2 24 3,37 g/l 4,1 % 3,0 % 5,1 %
Avaliação dos resultados
Actualmente, utilizam-se vários métodos para a apresentação dos valores do tempo de TP. Para o
Reagente Dade® Innovin® existe um valor “International Sensitivity Índex” (ISI), específico para o lote e Bibliografia
o aparelho, que possibilita a indicação dos valores de pacientes sob a forma de um “International Nor- Veja o manual de instruções em inglês.
malized Ratio” (INR)4.O cálculo e a aplicação do INR estão descritos mais abaixo. A indicação do INR é * não está disponível nos EUA
utilizada, preferencialmente, para documentar os resultados das amostras de pacientes anticoagulados ** O tempo médio normal de TP ou MNPT (= Mean Normal Pathrombin Time) é definido como o valor
por via oral. Alternativamente, para a determinação do resultado, o tempo de TP de pacientes (em médio do intervalo normal. Tem de ser determinado, especialmente, para cada lote de Tromboplastina
segundos) pode ser usado em conjunto com o intervalo de referência (em segundos). com o método usado para a análise das amostras do paciente ou o coagulómetro utilizado para esse
Exemplo: Resultado do paciente 18 segundos; intervalo de referência 9,7 - 12,3 segundos. fim.
Determinação do INR (International Normalized Ratio) Ci-Trol, Dade e Innovin são marcas comerciais da Siemens Healthcare Diagnostics.
Valores para o Reagente Dade® Innovin®
Sysmex é uma marca comercial da SYSMEX CORPORATION.
Estandardização internacional do tempo de TP (tempo de Tromboplastina) para monitoração das tera-
pias orais de anticoagulantes. A compra de Dade® Innovin® confere ao comprador uma licença limitada para utilizar a Dade® Innovin®
1. Em conformidade com as recomendações conjuntas da World Health Organization (WHO)4 e do adquirida, abrangida pelas patentes norte-americanas n.ºs 5,625,036, 7,084,251 e 7,049,131 de acordo
International Committee on Thrombosis and Haemostasis, os valores do tempo de TP de pacientes com as instruções aqui apresentadas
que se encontrem sob terapia oral de anticoagulantes deverão ser indicados como valores de INR.
Os valores de INR são independentes dos reagentes e métodos usados e estão previstos, espe-
cialmente, para o diagnóstico de pacientes estabilizados com uma terapia oral de anticoagulantes a
longo prazo.
O INR é determinado de acordo com a seguinte equação4:
Edição Maia 2008
Tempo de TP do paciente
INR = RISI, sendo que R = ——————————————
MNPT**
ISI é o International Sensitivity Index da combinação de reagentes/aparelhos.
B4212 G40 E0501 (837) 7
© 2008 Siemens Healthcare Diagnostics Products GmbH
All rights reserved.
B4212 G40 E0501 (837) 8

You might also like