No Item As Specified As Offered Remarks 1 Fire Detection and Two-Way Communication System
No Item As Specified As Offered Remarks 1 Fire Detection and Two-Way Communication System
1.1
1.2 Fire Alarm Control Panel
1.3
1.4
1.5 Manufacturer
1.6 Type USA/EU/JAPAN
1.7 Model
1.8 Country of Origin Country of Manufacture
1.9 UL Listed - Yes/No LPCB certified Yes/No
1.10 Complying Standard
Importer/Agent
Dimensions: Length (mm) Height (mm)
Width (mm)
1.11 No of characters in the display (please
specify)
1.12 Finish of panel
1.13 No. of zones
1.14 No. of alarm line
1.15 Maximum loading
1.16 No of devices per loop
1.17 Alarm line (mA) Main power supply
1.18 Voltage (V)
Frequency (Hz) System operating voltage
(V) Power consumption (W) Battery type
Battery capacity (A.hrs) Integral charger (A) Minimum 10
1.19 Recharge period (hrs) Maximum 80%
1.20 Minimum 200
1.21 Standby on main failure (hrs.) Fault
No
1.22 Item
indication As specified
Clause 2.9 As offered Remarks
1.23 230 VAC
1.24 50 Hz
24 VDC Clause 2.6
1.25 Clause 2.12
1.26 Clause 2.12
Clause 2.12
Clause 2.12
Clause 2.13
Clause 2.12
Clause 2.6
1.27 Device/loop Open circuit - Yes/No Clause 2.5
Short circuit - Yes/No Annex C
Earth fault - Yes/No
Clause 2.5.6 Clause
C.4
Alarm Open circuit - Yes/No Short ClauseC.2 (Annex C)
1.28 circuit - Yes/No Earth fault -Yes/No Clause 2.5
Alarm silenced -Yes/No Clause 2.5.2
Clause A.13 (Annex A)
Clause 2.5.4
Power Main fail - Yes/No Clause C.2 (Annex C)
Clause 2.5.3
Clause C.1 (Annex C)
1.29
Battery low voltage- Yes/No
USA/EU/JAPAN
CCTV System
1.33
1.35
Repeater Panel
1.36
Manufacturer
Make
Type
2 Country of Origin
Country of Manufacture
2.1
2.2
2.3
2.4
2.5
No Item As specified As offered Remarks
3.10
3.11
3.12
4 Manual Call Points (Addressable) Clause 2.10.5
4.1 Manufacturer
4.2 Make
4.3 Type
4.4 Country of Origin Country of Manufacture
4.5 UL Listed - Yes/No LPCB certified Yes/No USA/EU/JAPAN
4.6 Complying Standard
4.7 Type
4.8 Operating Voltage VDC
4.9
4.10
Fire Resistance Cable
6.1
6.2
6.3
6.4
6.5 USA/EU/JAPAN
6.6
6.7
6.8
6.9
7 Duct Smoke Detector (Addressable) Clause 2.10.1
Clause 2.10.4
7.1
7.2 Manufacturer
7.3 Make Type Model
7.4 Country of Origin Country of manufacture
7.5 UL Listed - Yes/No LPCB certified Yes/No
7.6 Complying Standard
7.7 USA/EU/JAPAN
7.8
7.9 Heat Detector (Addressable)
8
Manufacturer
Make Type Model
8.1 Country of Origin Country of manufacture
8.2 UL Listed - Yes/No LPCB certified Yes/No Clause 2.10.1
8.3 Complying Standard Clause 2.10.3
8.4
8.5
8.6 Alarm Sounder
8.7
8.8 Manufacturer
8.9 Make Type Model
Country of Origin Country of manufacture
UL Listed - Yes/No USA/EU/JAPAN
9
9.8
9.9
USA/EU/JAPAN
9.10
9.11
24 VDC
At least 90 dB
10 Alarm Sounder with Strobe Clause 2.10.9
10.1 Manufacturer
10.2 Make Type Model
10.3 Country of Origin Country of manufacture
10.4 UL Listed - Yes/No LPCB certified Yes/No
10.5 Complying Standard
10.6 Operating Voltage VDC Normal
10.7 Current mA Sound level in 3 m USA/EU/JAPAN
10.8 distance dB Sound frequency Hz (please
10.9 specify) Strobe flash rate (please
specify) Strobe colour (please
specify) Degree of Protection
10.10
10.11 24 VDC
10.12
10.13 Intelligent Monitor Module
10.14 (Addressable) At least 90 dB
Manufacturer
Make Type Model
Country of Origin Country of manufacture
11 UL Listed - Yes/No IP 65
LPCB certified Yes/No
Complying Standard
11.1
11.2
No
11.3 Item As specified As offered Remarks
11.4 Clause 2.10.6
11.5
11.6
11.7
11.8
11.9
USA/EU/JAPAN
12 Intelligent Control Module Clause 2.10.7
(Addressable)
Manufacturer
12.1 Make Type Model
12.2 Country of Origin
12.3 Country of manufacture
12.4 UL Listed - Yes/No LPCB certified Yes/No
12.5 Complying Standard USA/EU/JAPAN
12.6 Exit Sign
12.7
12.8 Manufacture
12.9 Make
13 Country of Origin and Manufacture
13.1 Model
13.2 Operating Voltage VDC Normal Clause 2.14
13.3 Current mA Dimensions :
Length (mm) Height (mm)
13.4 Width (mm) Battery type
13.5 Recharge period (hrs)
13.6 Standby on main failure (hrs.) USA/EU/UK/JAPAN/
13.7 Canada/ Australia
Video Display Terminal
Manufacture 24 VDC
Make Type Model
13.8 Operating Voltage V Normal
13.9 Current mA Any Other
No
13.10 Item As specified As offered Remarks
14
15 Printer 230 VDC
14.1
14.2
15.1
14.3 Manufacture
15.2
14.4 Make Type Model
15.3
14.5 Operating Voltage V Normal Minimum 3hrs
15.4
14.6 Current mA
15.5
14.7
15.6 Clause 2.8
1.1.3 Type
Wet
100mm
Vertical
1.3.4 Type
1.3.5 Noise level (dB)
1.5.4 Type
1.5.5 Material
1.5.6 Rated working pressure
Clause 5.6.5
1.6.4 Type
1.6.5 Material
2.2.4 Type
2.2.5 Diameter (mm)
2.2.6 Length
2.2.7 Material
3.4 Importer/Agent
3.5 Fire Hose: Reinforced rubber
19
3.5.1 Material 45
Clause 5.5.5
3.5.2 Diameter (mm) 6.35
3.5.3 Length (m) Clause 5.5.5
3.5.4 Nozzle Material
3.5.5 Diameter (mm)
3.5.6 Maximum operating pressure
4 Fire Pipes
4.7 Material
5 Pressure Gauges
6 Sprinklers
Min 48
6.1.5 Material
6.1.6 Bore size mm
6.1.7 Nominal K factor Min 0.35
6.1.8 Spray angle 68
6.1.9 Flow (L/min)
6.1.10 Discharge velocity (m/sec)
6.1.11 Operating pressure (bar)
6.1.12 Operating temperature (°C)
6.2.5 Material
6.2.6 Bore size mm Min 48
6.2.7 Nominal K factor
6.2.8 Spray angle
6.2.9 Flow (L/min) Min 0.35
6.2.10 Discharge velocity (m/sec) 68
6.2.11 Operating pressure (bar)
6.2.12 Operating temperature (°C)
7.1.3 Importer/Agent
7.1.4 Model Stored pressure
type
7.1.5 Type 9
USA/EU/UK/
8.1.2 Country of Origin and Manufacture Japan/Canada
/ Australia
8.2.1.3 Type
8.2.1.4 Material
Item As specified As Remarks
8.2.1.5 Nominal Diameter (mm) offered
8.2.1.6 Rated working pressure, (bar)
8.2.2.3 Material
8.2.2.4 Type
8.2.2.5InertPressure
8.2.3 rating
Gas Agent (bar)Orifice
Main Clause 6.8.4
8.2.4.5
Item Material As specified As Remarks
offered
8.3 Discharge Nozzle Clause 6.8.5
8.3.1 Manufacturer USA/EU/UK/
Japan/Canada
8.3.2 Model / Australia
8.3.3 Type
98.3.6 InertWorking
Gas Agentpressure (bar)
Fire Detection & Actuation
System
8.3.7 Material
9.1 Fire Detection Panel Clause 6.9.1
9.1.1 Manufacturer USA/EU/UK/
Japan/Canada
9.1.2 Model / Australia
9.1.3 Type
9.1.5 Dimensions (W x H x L)
a) Voltage (V)
b) Frequency (Hz)
9.2.3 Type
9.2.5 Dimensions (W x H x L)
9.3.3 Type
9.3.5 Dimensions (W x H x L)
9.3.6 System
9.4 Manual Calloperating
Points voltage (V)
9.3.7 Power consumption (W)
9.4.1 Manufacturer USA/EU/UK/
Japan/Canada/
9.4.2 Model Australia
9.4.3 Type
9.4.5
Item Operating Voltage, VDC As specified As Remarks
offered
9.5 Smoke/Heat Detector
9.5.1 Manufacturer smoke or heat
USA/EU/UK/
9.5.2 Model Japan/Canada/
Australia
9.5.3 Type
9.6.3 Type
9.6.7 Sound
9.7 Alarm level with
Sounder in 1mStrobe
distance, dB
9.7.1
94.6.8 Manufacturer
Sound frequency, Hz USA/EU/UK/
Japan/Canada/
9.7.2 Model Australia
9.7.3 Type
9.8.3 Importer/Agent
9.8.4 Model
9.9 Fire Resistant Cable
9.8.5 Type
9.9.1 Manufacturer USA/EU/UK
a) Temperature (oC)
10 Flexible Connection for Sprinklers & Pipe Supports
b) Duration (hrs.)
UL/FM
10.2.3 Standard
10.2.4 Material
10.2.5 Certification
10.3 Hangers Clause 5.9.4
10.3.1 Manufacturer USA/EU/UK/
Japan/Canada
10.3.2 Country of origin and Manufacture / Australia Loop
Hanger/ Clevice
Hanger UL/FM
10.3.3 Standard
10.3.4 Type
10.3.5
11 Certification
Grooved Fittings
a. Manufacturer USA/EU/UK/
Japan/Canada/
b. Country of Origin and Manufacture Australia
11.5 Certification
No Item As specified As offered Remarks
6.1 Sprinkler (pendent - concealed type)