Professional Documents
Culture Documents
Final Year Project
Final Year Project
A
FINAL YEAR PROJECT REPORT
ON
SUPERVISOR
Er. AAKARSHA KHAWAS
SUBMITTED BY
AAYUSH ADHIKARI (2073/BCE/003)
ARBIN KC (2073/BCE/014)
BIDHUSI KOIRALA (2073/BCE/025)
BARADAN RAYAMAJHI (2073/BCE/019)
CERTIFICATE
DECLARATION
We, hereby, declare that this report entitled “Seismic Analysis and Design of
Multistoried Institutional Building ” is our original team-work output accomplished
in the form of partial fulfillment of the requirement for the Bachelor’s Degree in Civil
Engineering, under the supervision of Er. Pujan Raj Regmi.
We would like to express our immense gratitude to our supervisor, Er. Pujan Raj
Regmi, who warmly embraced us and helped us in every possible manner and
provided us guidance and support leading us to complete this report on time.
We would also like to thank our teachers and instructors, Er. Arjun Poudel (Head of
Civil Engineering Department), Er. Bikash Raj Joshi (Project Coordinator), and the
whole civil department for their patient guidance. Also, we are grateful to our fellow
classmates for sharing their knowledge during the preparation of this report.
We are also thankful to our seniors for sharing with us their experience and guiding us
with the preparation of the report.
We apologize for any mistakes that may be found in the report and hope for
constructive criticism.
Thanks for everything.
The use of reinforced concrete as a constructional material, for building shelters has
increased significantly in last few decades, especially in the urban areas of Nepal.
There may be various reasons which lead to the design of building by proper analysis,
design and detailing with respect to safety, economy, stability, strength. The
verification of quality of design of the various structural components of a building
before construction and quality control of work during construction is important.
Moreover, considerations of different types of loads that are to act during service life
of structure is must. This report presents all considerations made, procedure adopted
and results obtained for the structural design of commercial building to be constructed
in Kathmandu.
The purpose of this report is to present the necessary background in using the method
set out in IS: 456-2000, IS: 875 part (I, II), IS: 13920-1993 for ductility and seismic
code and IS: 1893-2016.The report comprises all the subject matter regarding the
topic of concern, maintained in sections and annexes. In this report, special care has
been taken to the analysis of vertical and lateral forces and detailing of structural
elements and is conformed to respective codes in every way possible.
Every care has been taken to make this report free of errors, yet slip may occur.
We warmly welcome constructive criticism and shall be obliged, if errors are
brought to our notice.
TABLE OF CONTENTS
SUMMARY..................................................................................................................1
METHODOLOGY.....................................................................................................................2
ABBREVIATIONS....................................................................................................................3
1. OVERVIEW...........................................................................................................................7
1.1. INTRODUCTION...........................................................................................................7
1.3. OBJECTIVES..................................................................................................................9
1.9. DESIGN.........................................................................................................................11
1.10. DETAILING..................................................................................................................12
1.11. SCOPE...........................................................................................................................12
2. REVIEW OF LITERATURE.............................................................................................13
2.1 BACKGROUND...........................................................................................................13
2.3 LOADS..........................................................................................................................19
3. METHODOLOGY AND PRELIMINARY DESIGN.......................Error! Bookmark not
defined.29
4.1 INTRODUCTION.........................................................................................................33
4.2 ANALYSIS....................................................................................................................33
6.6 DRIFT:...........................................................................................................................64
7. CONCLUSION....................................................................................................................65
7.1 ANNEXES……………………………………………………………………...
ANNEX 1
ANNEX 2
ANNEX 3
ANNEX4
ANNEX5
ANNEX6
ANNEX7
8. BIBLIOGRAPHY................................................................................................................66
SUMMARY
The adequately design buildings could be helpful in saving lives and properties from
unpredicted failure of building structures. The aim of reinforced concrete design is the
achievement of an acceptable probability that structures being designed will perform
satisfactorily during their intended life. With an appropriate degree of safety, they
should sustain the entire load and the deformation of normal construction and use and
have adequate durability and adequate resistance to the effect of misuse and fire.
We are mainly dealing with seismic analysis and structural design of RCC framed
concrete structure. Our main focus will be on obtaining design output by limit state
method on basis of structural design incorporating seismic considerations Keeping in
mind all these facts and the limitation of the manual calculations, the use of computer
has been taken as the important aspect of our project. Various software like ETABS,
Autodesk (AutoCAD), Microsoft Word and MS- Excel were used for the completion
of our project work.
Structure and structural elements are normally designed by limit state method. Proper
account is taken of accepted theories, experiment and experience and the need to
design for durability. Calculation alone does not produce safe, serviceable and durable
structures. Suitable materials, quality control, adequate detailing and good supervision
are equally important.
1
METHODOLOGY
The entire process adopted for the status evaluation of RCC building can be summed
up in the schematic flowchart as shown below.
Fig: Schematic flowchart of process adopted for the status evaluation of RCC
building.
Analyzing Given
Architecture Plan
Viewing Plan
Preparation of Irregularity
Functional Map
IS:456-2000 IS:875
IS:13920 Preliminary Design
Modeling
Analysis
Of No
Safety o
Yes
IS:456-2000 IS:13920
Do Detailing
SP 16 / SP 34
& Design
2
ABBREVIATIONS
3
LL Live Load
RC Reinforced Concrete
SP Special Publication
R/F Reinforcement
BM Bending Moment
L Live load
X Spacing of stirrups
P Percentage of steel in the section
Pu Factored design axial load
Puz Capacity of the cross section under pure axial load
Mu Factored design moment
Mlim Limiting factored moment of resistance
Muy Factored designed moment about Y-axis
Muyl Maximum moment capacity for bending along Y-axis
Mux Factored design moment along X-axis
EQX Earthquake load along x-direction
EQY Earthquake load along Y-direction
RLL Reduced live load
VB Base shear
Vu Factored shear force
M.O.I Moment Of Inertia
4
SALIENT FEATURES OF THE PROJECT
PHYSICAL PROPERTIES:
Project name “Seismic Analysis and Design of Multistoried
Institutional Building.”
Location: Kathmandu.
Total number storey: 7( including basement)
Total height: 25.5m
Floor to floor height: 3.75 m
Overall length: 23.734m
Overall breadth: 22.901m
Plinth area: 469.895 m2
Earthquake zone: V
STRUCTURAL PROPERTIES:
Total number of Column: 100
Section of column: 650mm X 650 mm
Section of beam: 700 mm X350 mm
Depth of slab: 150 mm
Foundation depth: 1000mm
5
Importance Factor, I: 1.3
1. OVERVIEW
1.1. Introduction
The bearing capacity of foundation soil at site condition is taken as 140 KN/m 2 and
foundation was designed accordingly. The structural analysis was done with help of
computer software ETABS and design was done on spreadsheet applications like MS-
EXCEL, MS-WORD.
A designer has to deal with numerous structures ranging from simple to more
complex ones like a multistoried frame building. All the structural members are
subjected to various loads viz. concentrated loads, uniformly distributed loads, live
loads, earthquake load, wind load, etc. The structure transfers the loads acting on it to
the supports and ultimately to the ground. While transferring the loads acting on the
structure, all members of the structure are subjected to the internal forces like axial
forces, shear forces, bending and torsion moments.
Structural Analysis deals with analyzing these internal forces in the structural
member developed as a result of various loading conditions or combinations.
Structural Design deals with sizing various members of the structures to resist the
internal forces to which they are subjected in the course of their life cycle. Unless the
proper structural detailing method is adopted the structural design will be no more
effective. A Standard Code of practice (Indian Standard code in our case) should be
thoroughly followed and implemented for proper analysis, design and detailing with
6
respect to safety, economy, stability, strength.
Besides the scarcity of land, earthquake is one of the dominant constraints while
designing the multistory frame building in earthquake prone zone like Kathmandu.
According to IS1893: 2016, Kathmandu lies on V zone, the severest one, hence the
effect of earthquake is predominant to wind load. So, the building is analyzed for
earthquake as lateral load. The seismic coefficient design method as stipulated in IS
1893:2016 is applied to analyze the building for earthquake. The 3- dimensional
moment resistance frame with shear wall is considered as the main structural system
of the building.
Wind load is not considered in our project considering geography of our location. The
wind load and seismic loads are assumed not to act simultaneously. A building is
designed for the worst of the two loads. The estimation of live and dead load could be
predicted with reasonable accuracy but the loads due to earthquake can’t be accurately
predicted. So, statistical and probabilistic approaches are resorted to, considering one
of factor economy.
This project work has been undertaken for the partial fulfillment of requirements for
the Bachelor’s Degree in Civil Engineering. This project work contains structural
analysis, design and detailing of a multi storey building. All the theoretical knowledge
on analysis and design acquired during the course works are utilized with practical
application. The main objective of the project work is to acquaint us in the practical
aspects of Civil Engineering.
This group under the project work has undertaken the Computer Aided Structural
Analysis and Design of Multi Storey Building. The main aim of the project work
under the title is to acquire knowledge and skill with an emphasis on practical
application. Besides the utilization of analytical methods and design approaches,
exposure and application of various available codes of practices is another aim of the
work.
7
1.3. Objectives
a. Preparation of the plan of the building to meet the requirements for its
intended use.
b. Identification of the structural arrangement of the plan.
c. Modeling the building for structural analysis.
d. Analyzing the structure using structural analysis program.
e. Sectional design of the structural members.
f. Preparation of detail structural drawing of the design.
8
length is designed with one or more expansion joints.
The design is intended to serve quality service to the general public round the clock.
Various assumptions have been made in analysis and design of the structures, for
consideration of simplicity and economy, viz.:
9
4. Centerlines of beams, columns and shear walls are concurrent everywhere.
The building is modeled as a space frame. ETABS 18.1.1 is adopted as the basic tool
for the execution of analysis. ETABS 18.1.1 program is based on Finite Element
Method. Due to possible actions in the building, the stresses, displacements and
fundamental time periods are obtained using ETABS 18.1.1 which are used for the
design of the members.
1.9. Design
The following materials are adopted for the design of the elements:
Concrete Grade:
i. M30 for the beams, slabs and foundation
ii. M30 for columns
Reinforcement Steel:
i. Fe 500 for staircase and other structural members
The design of RC elements is carried out using Limit State Method. The design is
based on Indian Standards Code of Practice for Plain and Reinforced Concrete IS
456-2000, Design Aids for Reinforced Concrete to IS 456:1987(SP-16), Criteria
for Earthquake Resistant Design Structures IS 1893-2016, Ductile Detailing of
Reinforced Concrete Structures Subjected to Seismic Forces IS 13920:1993.
The design moments, shear forces, axial forces and torsions are taken as computed
by computer software program "ETABS 18.1.1" for the worst possible combination
and a number of hand calculations are done so as to verify the reliability of the
design results suggested by the software.
10
1.10. Detailing
The space frame is considered as a Special Moment Resisting Frame (SMRF) with
a special detailing to provide ductile behavior and comply with the requirements
given in IS 13920:1993 aided by SP 34.
1.11. Scope
The project work is limited to the structural analysis and design only. Design and
Detailing of following structural elements is performed:
1. Slab
2. Beam
3. Column
4. Staircase
5. Lift and Shear wall
6. Mat Foundation
11
2. REVIEW OF LITERATURE
2.1. Background
We are mainly dealing with seismic analysis and structural design of RCC framed
concrete structure. Our main focus will be on obtaining design output by limit state
method on basis of structural design incorporating seismic considerations.
Earthquake is the natural phenomena caused by release of seismic wave (p-wave and
s- wave) from the earth surface from a faint tremor to a wild motion due to sudden
release of energy stored to the rocks beneath the earth surface. It occurs in clusters. It
dates as old as earths’ history itself, however, our knowledge and interpretations about
their behavior & ways to minimize damages due to them is recent. Most of the
earthquake are minor and go un-noticed but the major ones, though occasional are
responsible for huge loss of life and property.
12
2.2. Design Philosophy
There are three philosophies for the design of reinforced concrete viz.
Among above, Limit state method has been adopted for the design of the structural
elements.
Limit state design has been originated from ultimate or plastic design. The object of
design based on the limit state concept is to achieve an acceptable probability that a
structure will not become unserviceable in its life time for the use for which it is
intended, i.e. it will not reach a limit state. A structure with appropriate degrees of
reliability should be able to withstand safely all the loads that are liable to act on it
through-out its life and it should satisfy the serviceability requirements. All relevant
limit states must be considered in design to ensure an adequate degree of safety and
serviceability.
13
e. The stresses in the reinforcement are derived from the representative stress-
strain curve for the type of steel used. For design purpose the partial safety
factor ym =1.15 shall be applied.
f. The maximum strain in the tension reinforcement in the section at failure shall
not be less than:
fy
+ 0.002
1.15 E s
14
Assumptions for the limit state of collapse in compression
In addition to the assumptions for limit state of collapse in flexure from 1 to 5, the
following shall be assumed:
The most important of these limit states which must be examined in design are as
follows:
This state corresponds to the maximum load carrying capacity. Violation of collapse
limit state implies failure in sense that a clearly defined limit state of structural
usefulness has been exceeded. However, it does not mean a complete collapse. This
limit state may correspond to:
A. Flexure
B. Compression
C. Shear and
D. Torsion.
This state corresponds to development of the excessive deformation and is used for
checking members in which magnitude of deformation may limit the use of the
structure or its components. This state may correspond to:
15
a. Control of Deflection
The deflection of a structure or part there of shall not adversely affect the appearance
or efficiency of the structure or finishes or partitions. Two methods are given in code
for checking the deflections. These are:
• Limiting the span/effective depth ratio given in clause 23.2, IS: 456-2000
which should be used in all normal cases, and
• Calculation of deflection given in Appendix C of code to be followed in
special cases.
b. Control of Cracking
• Expression for crack width and spacing, and (Annex F of IS: 456-2000).
• Allowable crack widths under different service conditions with due
considerations to corrosion and durability of concrete (clause no 35.3.2 of IS:
456-2000).
• Unless the calculation of crack widths shows that a greater spacing is
acceptable, for the flexural members in normal internal or external conditions
of exposure, the maximum distance between bars in tension shall not exceed
the value as given in IS:456-2000, clause no 26.3.3.
• Cracks due to bending in compression member subjected to design axial load
>0.2fck*Ac, need not be checked. For flexural members (A member which is
subjected to design load <0.2fck*Ac) if greater spacing of reinforcements as
given in clause 26.3.2, IS456-2000 is required, the expected crack width
should be checked by formula given in Annex F of IS 456-2000.
c. Control of Vibration
A dynamic load is any load of which the magnitude, direction or position varies with
the time and almost any RCC structural system may be subjected to one form or
16
another loading during its life-time. Similarly, structural response i.e. resulting
stresses or deflections is also time-varying or dynamic and is expressed in terms of
displacements.
The limit state concept of design of reinforced concrete structures takes into account
the probabilistically and structural variation in the material properties, loads and
safety factors.
2.3. Loads
Basic objective of constructing building or any structure is to support loads. There are
different types of loads, which come across and have to be dealt during analysis and
design of any structure.
The buildings and structures are subjected to number of loads, forces and effects
during their service life such as those listed in IS: 456-17 and IS: 875-8.1. The
following loads usually determine the size of structural element:
The following are the cause which generally causes internally-equilibrated stresses
forming cracks in structure, but not collapse.
a) Foundation movement,
b) Axial elastic shortening,
c) Shrinkage,
d) Temperature changes, etc.
The proposed building is a RCC framed structure, located in Kathmandu. Thus wind
loads, snow loads, and other special types of loads described by IS: 875 (part 5):1987
can be taken as negligible as compared to the dead, live and seismic loads.
a) Dead Loads:
According to the IS 875:1987(Part I), the dead load in a building shall comprise the
weights of all walls, partitions, beam, column, floors and roofs and shall include the
weights of all other permanent features in the building.
b) Live Loads:
It means the load assumed or known resulting from the occupancy or use of a
building and includes the load on balustrades and loads from movable goods,
machinery and plant that are not an integral part of the building. These are to be
chosen from codes as IS:875: 1987(Part 2) for various occupancies where required.
These codes permit certain modifications in the load intensities where large
contributory areas are involved, or when the building consists of many stories.
When transferring the loads from parapets, partition walls, cladding walls and facade
walls etc. to the supporting beams or columns, the eccentricity with these loads should
be properly considered in the case of rigid frames of reinforce concrete. Such
eccentricities will produce externally-applied joint moments similar to these arising
18
from projecting cantilevers and these should be included in frame design.
d) Seismic Loads:
These are the load resulting from the vibration of the ground underneath the super-
structure during an earthquake. The earthquake is an unpredictable natural
phenomenon. Nobody knows the exact timing and magnitude of such loads. Seismic
loads are to be determined essentially to produce an earthquake resistant design.
19
An earthquake-resistant building has four virtues in it, namely:
I. Good Structural Configuration:
Its size, shape and structural system carrying loads are such that they ensure a
direct and smooth flow of inertia forces to the ground.
The maximum lateral (horizontal) force that it can resist is such that the damage
induced in it does not result in collapse.0
Its lateral load resisting system is such that the earthquake-induced deformations in
it do not damage its contents under low-to-moderate shaking.
Its capacity to undergo large deformations under severe earthquake shaking even
after yielding, is improved by favorable design and detailing strategies. Seismic
codes cover all these aspects.
It is most important step in structural design. Proper recording of them required for
confusion free analysis.
2.2.
1. Calculate the weight of those elements of building whose dimensions are fixed
already from functional considerations and can be worked out carefully. These
20
are generally non-structural elements and of parapets, rooftop, railings etc.
2. From pre design, calculate weight of structural elements such as beam,
column, slab etc.
3. Put all loads systematically on sketches, say plan wise, showing their gravity
lines with reference to column center-lines.
Select live load intensity occupancy-wise as applicable for slabs and beams from the
code and write this on plan. The reduction of live load intensities for the number of
storey in the columns and that for calculating earthquake loads may be considered in
the calculations later.
IS: 1893- 2002 was followed for the calculation of the earthquake loads, which
specifies two methods which are:
TERMINOLOGY
I. Response spectra:
21
damping values.
The seismic analysis can be performed using design spectrum given in below figure;
which is based on strong motion records of eight earthquakes in India.
Fig 2.3 Response spectra for rock and soils for 5% damping (source IS: 1893-2002)
The seismic analysis can be performed using design spectrum. Response spectrum
method is dynamic analysis used for the analysis of seismic loads for unsymmetrical
buildings.
22
Base shear ( V b )= A h∗W
Where,
ZISa
Ah =
2 Rg
Where,
Sa
( ) = Structural response factor
g
Clause7.6.2,IS 1893:2016
23
0.09∗h
T a=
√d
Where,
D = Base dimensions of the building at the plinth level, in meter, along considered
direction of the lateral force
The response reduction factor assigned to different types of structural systems reflects
design and construction experience, as well as evaluation of performance of structure
in major and moderate earthquakes. It endeavors to account for the energy absorption
capacity of the structural system by damping (which is normally taken as 5% of
critical damping for RCC structures) and in-elastic action through several load
reversals.
The R values reflect the degree of continuity and ductility provided for the structural
systems. A building with a value R equal to 1.0 corresponds to a structural system
exhibiting little or no ductility and value greater than 1.0 is presumed to be capable of
undergoing inelastic cyclic deformation.
The value of R is taken as 5 for RCC moment resisting frame specially designed
to provide ductile behavior and comply with requirements given in IS:13920-
1993.
24
IV. Closely spaced modes:
Closely spaced modes of structure are those of its natural modes of vibration whose
natural frequencies differ from each other by 10 percent or less of the lower frequency
i.e.
ωj−ωi
≤ 0.1
ωi
Where,
V. Storey drift:
VI. Regularity:
The regularity of a building can significantly affect its performance during a strong
earthquake. Past earthquakes have repeatedly shown that buildings having irregular
configurations suffer greater damage than buildings having regular configuration.
25
system. They may have; either plan irregularity or vertical irregularity or mass
irregularity.
26
2.3.4. Load Combinations
The analysis was performed for various 20 combinations and time history separately.
Following are those 20 combinations as suggested by IS: 1893-2016, Clause 6.3.1
1) 1.5 DL
2) 1.5(DL + LL)
3) 1.2 (DL + LL + EQx)
4) 1.2 (DL + LL- EQx)
5) 1.2 (DL + LL + EQy)
6) 1.2 (DL + LL - EQy)
7) 1.5 (DL + EQx)
8) 1.5 (DL - EQx)
9) 1.5 (DL + EQy)
10) 1.5 (DL - EQy)
11) 0.9 DL + 1.5 EQx
12) 0.9 DL - 1.5 EQx
13) 0.9 DL + 1.5 EQy
14) 0.9 DL - 1.5 EQy
15) 1.2 (DL + LL + RSx)
16) 1.2 (DL + LL + RSy)
17) 1.5 (DL + RSx)
18) 1.5 (DL + RSy)
19) 0.9 DL + 1.5 RSx
20) 0.9 DL + 1.5 RSy
27
3. METHODOLOGY AND PRELIMINARY DESIGN
Any structure is made up of structural elements (load carrying, such as beams and
columns and non-structural elements (such as partitions, false ceilings, doors). The
structural elements put together, constitute the structural systems. Its function is to
resist effectively the action of gravitational and environmental loads, and to transmit
the resulting forces to the supporting ground without significantly disturbing the
geometry, integrity and serviceability of the structure.
The planning of the building has been done by the group. The final plan of the
building was a result of review of various codes of practice and some other reference
books suggested by our Supervisor. The positioning of the columns and staircases are
appropriately done and accordingly beam arrangement is carried out so that the whole
building will be aesthetically, functionally and economically feasible.
The aim of the design is the achievement of an acceptable probability that structures
being designed will perform satisfactorily during their intended life with an
appropriate degree of safety, they should sustain all the loads and deformations of
normal construction and use and have adequate durability and resistance to the effect
of misuse and fire.
All the data required for this project work have taken from different literatures.
Design parameters have been taken from Indian Standard code of practices.
28
3.4. Load Calculation
Load calculation has been done using the IS 875-1987(Part 1 & Part 2) as reference.
The exact value of unit weight of the materials used in the building for calculation for
weight has been taken from the code. Thickness or depth of materials or section was
fixed as per requirement and according to specifications in code.
I. Dead load
II. Live load
I. Self-weight of beam
II. Load transferred from slab
The finite element method can be used to analyze slabs of any shape, boundary
condition and subject to any loading. This method can also account for stiffness of the
supporting beams. This method is extremely useful for slabs with opening and those
subjected to concentrated loads.
Two way slabs can also be analyzed using the ultimate load theory, Yield line theory
is the most popular. In this theory, the strength of slab is assumed to be governed by
flexure alone. The effects of shear and deflection are to be considered separately. It is
assumed that a mechanism is formed in the slab at failure. The reinforcing steel is
assumed to have fully yielded along the yield lines or cracks at failure.
29
Fig 3.1 Cracking in 2-way slabs
Here, considered
Crack or yield lateral load is from earthquake only. Seismic load of building or
pattern
structure depends upon its geographic location, lateral stiffness, soil upon which it is
erected and it is reversible. Thus this effect has been considered along both axes of the
building taken one at the time.
1. Too many variations in the sizes of beam and columns, width and depth are
not desirable from both aesthetic and economical point of view. Minimum
dimensions of 200mm for small spans and 230mm~ 300mm for large spans
may be set for structural members.
2. Richer concrete mixes can be used in lower storey elements to avoid frequent
change in sections. Some size variation can also be avoided by reducing
column steel upwards in building.
3. Frequently column steel may be at odds with the longitudinal steel of beams
crossing it from one or more directions. Also cover required differs. It may be
useful to keep column wider than the beam and the number of bars be kept
even in column and odd in beam or vice-versa so that bars passes
uninterruptedly.
4. Narrow-deep beams may show shrinkage, temperature cracking in web and
also lateral buckling if laterally unsupported. This should be considered in
surface reinforcement detailing and ensuring lateral support on the
30
compression face at less than 25*b, b being beam breadth, where the effective
depth of beam exceeds 3 times of b.
The sections worked out as a result of preliminary design should be now recorded,
discussed with the architect and finalized before undertaking the further final analysis
which is more time consuming as well as more expensive.
31
4. MODELING AND STRUCTURAL ANALYSIS
4.1. Introduction
Load testing of a real structure to determine the responses is not possible all the times
due to economical, technical and environmental constraints. This fact leads to the
computer modeling of the complex structure by dividing it into simple elements of
known solutions. An appropriate model is a prerequisite for an appropriate design.
Nodal coordinates, elemental nodal connectivity, constraints conditions and loads are
the data required for the preparation of a structural model.
The structural analysis of the model is must to get the approximate response of
structure under the prevailing loading conditions. This response is then used to derive
the element internal forces and stresses, upon which the design of the element is
based.
4.2. Analysis
I. Manual calculation
2D-analysis
3D- analysis
Among various software, ETABS 18.1.1has been used for our purpose.
ETABS version 18.1.1 was used as a tool for modeling and analysis of the building.
32
ETABS is the most sophisticated and user friendly structural analysis program.
Creation modification of models, execution of analysis and checking and optimization
of the design can be done through this single interface. Graphical displays of the
results including real time, display of time history displacements are easily produced
in it. The analysis is done based on the principle of finite element method. In this
project the beams and columns were modeled as 3D frame elements and slab & shear
walls as 3D shell elements.
The finite element analysis program in ETABS involves of three stages of activities:
preprocessing, processing, post processing.
The processing stage involves the stiffness generation, stiffness modification and
solutions of equations resulting in the evaluation of nodal variables. Other derived
quantities such as gradients or stresses may be evaluated at this stage.
The post processing stage deals with the presentation of results. Typically, deformed
configuration, mode shapes, temperature and stress distributions are computed and
displayed at this stage.
Dynamic analysis shall be performed to obtain design forces and its distribution to
different levels/elements of building on following cases;
33
Table 4.1 (IS: 1893-2002)
In this method the design earthquake forces are determined adopting IS 1893:2002.
These design forces for the buildings located along two perpendicular directions may
be assumed to act separately along each of these two horizontal directions.
For structures having lateral force resisting element in two orthogonal directions only,
the earthquake forces is applied only along one direction X or Y at a time and the
building is designed. But for structures with frame in non-orthogonal directions, the
structural elements are designed for 100% of effect of seismic force in principle
direction combined with 30% of effect of seismic force in orthogonal direction.
This orthogonal effect is slight on horizontal elements like beam, slab etc. but
significant in vertical member like columns etc.
34
4.6. Interpretation of Analysis Data
The maximum internal forces and stresses developed due to various load
combinations and time history analysis was exerted using excel programs. The sample
results are presented in the appendix part.
The results obtained from ETABS were verified by hand calculations for few
elements and the comparison of these two results and probable reasons for the
variations are also presented in the appendix part.
Altogether, five structural elements; slab, beam, column, footing and staircase have
been designed. The design procedure for each structural element adopted is given
below.
5.1.1. Beam
The design of beam is governed by limit state of moment, shear and deflection. Shear
stirrups are provided to take care of the excess shear, beyond the shear capacity of the
concrete section of the beams.
35
d= D−( ∅ /2)−cc
6. Area of tension steel required for additional bending moment (Mu — Mlim) is
calculated as
d'
Where, fsc for is taken from SP-16,
d
Table F, p.13
fcc = 0.446fck
7. Check for minimum area of tension steel from IS 456:2000, Cl.26.5.1.1 (a),
p.46-47.
Ao/bd = 0.85/fy
36
8. Check for maximum area of tension steel from IS 456:2000, Cl.26.5.1.1 (a), p.
47,
Ao= 0.04 bD
Permissible shear stress Ʈc is taken from IS 456:2000, Table 19, p.73 for
designed pt.
Vu
Ʈ v=
bd
Ʈc,maxis taken from IS 456:2000, Table 20, p.73 for designed grade of concrete.
If
Ʈc ≤ Ʈv ≤ Ʈc, max
Vus = Vu -Ʈc bd
Vus = (0.87fy*Asv*d)/x
Area and spacing of the stirrups is taken considering, spacing x < 0.75d and
<300mm
ρmin=(0.24 √ fck ) ⁄ fy ¿
ρmax= 2.5%
37
11. Ductility check for shear
Spacing x ≤ d/4
≤8ϕ ≥100 mm
38
5.1.2. Column
The design of column is governed by limit state of axial compression and bending
moments about two axes. Shear in column is small and shear stress work out to be
safe. Stirrups in column are provided mainly for holding column bars in place and
making them strong against bulking and bursting as these bars come under direct
compression. Moments in column change sign in each storey, so that, we generally
provide symmetrical bar arrangement in a column section and the steel area is kept
constant throughout a given storey.
The following steps are following in design of axially loaded column with biaxial
bending.
1. Size of column
2. If slenderness ratio = (le/LLD) < 12, Case: Short column
4. Axial force (Pu), moments (Mux &Muy) are taken from ETABS analysis.
5. Assume percentage of reinforcement, p, and carried out trial for this
percentage.
6. Find p/fck, d/D and pu/fckbd
7. Find (Mu/fckbD2) Referring to chart as per the value obtain from step 6 from
SP-16.
8. Calculation of Puz using
39
9. Find (pu/puz) , (Muy/Muy1) , (Muz/Muz1) and (αn)
10. Find (Muy/Muy1) αn+ (Muz/Muz1)αn
11. If (Muy/Muy1) αn+ (Muz/Muz1)αn< 1.0, Then O.K., If not , go for next trial
increasing p.
12. Design of diameter and pitch of lateral ties:
The diameter of lateral ties should not be less than one forth diameter
of largest longitudinal bar
ΦT ≥ ϕ/4
≥ 6mm
Pitch of ties:
≤ 16 0L
≤ 300mm
The spacing of hoops shall not exceed half the LLD of column.
Special confining reinforcement shall be provided over a length l0 from
each joint face
> LLD
>450mm
Lap splices shall be provided only in the central half of the member
Hoops shall be provided over the entire splices spacing of which should be
less than 150mm c/c at splices.
40
5.1.3. Slab
Slab panels are to be designed for the limit state of bending moment and deflection.
The thickness of slab is governed by deflection, while the steel areas at mid span and
support sections depend on the bending moments.
The slab is designed for 1m wide strips. The subsequent steps are followed to design
the slab.
lx = Lx + d
Positive and negative moments (αx and αy) are taken from IS:456-2000, Table
Ly
26, p.9 according to ratio.
Lx
M x =α x∗W ∗l 2x
M y =α y∗W ∗l 2x
Where, Mx and My are the moments on the strips of unit width spanning l x and
ly respectively.
41
ax and ay are bending moment coefficients,
8. Area of steel required for negative moment at continuous edge and positive
moment at mid span:
f y A stx
{
M x =0.87 f y A stx d 1−
db f ck }
For long span, it is calculated using following formula,
f y A sty
{
M y =0.87 f y A sty d 1−
db f ck }
9. Check for minimum steel from codes:
Spacing ≤3d
≤300mm
Area of each layer of steel at corners = 75% of area required for maximum
mid span moment
42
13. Shear is checked at the edge of short span.
Wulx
Vu=
2
v
Ʈv =
bd 1
For p & M20 grade concrete, Ʈ c is taken from IS 456:2000 Table 19 p.73 and k is
taken as per IS 456:2000, Cl.40.2.1.1, p.72.
Ld ≤(1.3M1/V) +Lo
L
≤ αβγδλ
d
5.1.4. Staircase
43
5. Calculation of area of steel
M = 0.87*fy*Ast( d–(fy*Ast/fck*b))
Vu = WuLx / 2
τv=v /bd 1
Percentage of steel,
p = (Asty / 2) / bd1
For p & M20 grade concrete, τc is taken from IS 456:2000, table 19 p.73 and k is
taken as per IS 456:2000, Cl.40.2.1.1, p.72.
5.1.5. Foundation
Foundations are the structural elements that transfer loads from the buildings or
individual columns to the earth. If these loads are to be properly transmitted,
foundations must be designed to prevent excessive settlement or rotation, to minimize
differential settlement and to provide adequate safety against sliding and overturning.
i. Isolated footings
ii. Strip foundation and wall footings
iii. Combined footings
iv. Raft or mat foundation
v. Pile foundation
44
Soil strata
Type of structure
Type of loads
Economy
Bearing capacity and standard penetration test value N of soil.
Permissible differential settlement, etc.
The choice is usually made from experience but it is advisable to carry out a
comparative study of different designs to determine the most economical.
For footings with moments or eccentricity about both axes, the soil pressure at any
point is given by the equation:
P My Mx
σ= ± x± y
A Iy Ix
Where,
45
There are situations where a footing must be built with a hole or notch and is, thus,
unsymmetrical in plan about both axes. The soil pressure distribution in such rigid
footings can be obtained from the principles of mechanics assuming linear
distribution. The desired equation is as follows:
P MyIx−MxIxy MxIy−MyIxy
σ= ± ( x )± ( y)
A IxIy−Ix y 2
IxIy−Ix y 2
Where,
If the loads transmitted by the column in a structure are so heavy or the allowable soil
pressure so small that individual footings would cover more than about one-half of the
area, it may be better to provide continuous footings under all columns and walls.
Such footing is called mat or raft foundation. Raft foundations are also used to reduce
the settlement of structures located above highly compressible deposits. When
earthquake forces are considered along with other normal design force, the
permissible stress in material and allowable bearing pressure of foundation soil can be
increased by 33% &50% resp. in the elastic method of design of mat foundation
(Clause no.6.3.5, IS: 1893-2002).
46
If the columns are equally spaced and their loads are equal, the pressure on the soil
will be uniform, otherwise moments of the loads may be taken about the same center
of the base and pressure distribution is determined using above formula. Since these
equations were derived from rigid member, and a raft is not a rigid member, the
pressure and resulting internal stresses may be seriously in error if the eccentricity is
very large. The weight of the raft is not considered in the structural design because it
is assumed to be carried directly by the sub-soil.
While designing the footing of building, preference should be given to the isolated
footing because of its simplicity & ease in construction, proper dealing of each
column load. But in our building, we design the mat foundation because each
individual footing would cover more than 50% of plinth area. The depth of footing is
ascertained by considering bending moment, one-way shear &two-way shear. The
depth required by one-way shear is excess. So considering the economy, depth
satisfying the B.M. & two-way shear is adopted and the deficiency in capacity to
resist one-way shear is designed by providing shear reinforcement to mat design.
1. Axial load for designed footing for load case 1.5 (Dead load +Live load) is
taken from ETABS.
2. Find approximate area of footing
3. Find type of foundation
4. For raft foundation, find eccentricity.
5. Find soil pressure intensity at different points
6. Divide raft in different strips equivalent to beams.
47
7. Find maximum moments
In X Direction M = wl2/10
In Y Direction M= wl2/8
8. Depth of foundation slab required from moment criteria and punching shear
criteria
d=Vuτv /bo
M = 0.87*fy*Ast (d–(fy*Ast/fck*b))
5.2.1. Beam
Beams in reinforced concrete building have two sets of steel reinforcements, viz. a)
long straight bars (longitudinal bars) placed along its length, and b) closed loops of
small diameter steel bars (stirrups) placed vertically at regular intervals along its full
length. Fig is shown below:
48
Designer should provide dimension A, S. d, anchorage length, cutoff points of
discontinuous bars. etc. 'provide not less than two stirrups throughout splice length.
A — distance to point of inflection plus anchorage length but not less than l/4.
Designer may cut some bars shorter than this but at least one-third the area of bars at
the face of column must extend this distance
dt - diameter of bar
Longitudinal bars are provided to resist flexural cracking on the side of the beam that
stretches. Since both top and bottom faces stretched during strong earthquake shaking,
longitudinal steel bar is required on both faces at the ends and on the bottom face at
mid length.
49
The Indian ductile detailing code IS 13920:1993 prescribes that:
a. At least two bars go through the full length of the beam at the top as well as
the bottom, of the beam.
b. At the ends of beams, the amount of steel provided at the bottom is at least
half that at top.
c. The diameter of stirrup must be at least 6mm; in beams more than 5m long, it
must be at least 8mm.
d. Both ends of the vertical stirrups should be bent into a 135° hook.
e. Extended sufficiently beyond this hook to ensure that the stirrup does not open
out in an earthquake.
f. The spacing of vertical stirrups in any portion of the beam should be
determined from calculations.
g. The maximum spacing of stirrups is less than half the depth of the beam. For a
length of twice the depth of the beam from the face of the column, an even
more stringent spacing of stirrups is specified, namely half the spacing
mentioned in (c) above.
h. The laps of longitudinal bars
ii) Should not be placed at locations where they are likely to stretch by large
amounts and yield.
5.2.2. Column
Columns, the vertical members in reinforced concrete buildings, contain two types of
steel reinforcements, viz. a) long straight bars (longitudinal bars) placed vertically
along the length, and b) closed loops of smaller diameter steel bars (transverse ties)
placed horizontally at regular intervals along its full length.
50
According to Indian ductile detailing code IS 13920:1993,
5.2.3. Slab
While using design of two way slabs with the help of coefficients, restrained slabs are
considered to be divided in each direction into middle and edge strips. The moments
apply only to the middle strips and no further redistribution is allowed for these
moments. The edge strips have to be reinforced only with nominal minimum steel for
crack control. In addition, corner steel to resist the torsion stresses produced in these
slabs are provided at discontinuous edges.
5.2.4. Staircase
The principles generally followed in placing steel in longitudinally spanning stairs are
51
as follows:
The maximum positive bending moment in the span for a simply supported
case is taken as (Wl2/8). One half of the tension steel is taken over the supports
as negative steel according to the usual practice in slabs.
Distribution steel as in the case of slabs (0.12% for Fe 500 steel) is also placed
on top of the main steel in the transverse direction.
Care should be taken while detailing of corners such that the steel when pulled
in tension does not tend to pull out the concrete over the reinforcement.
Altogether, detailed designs have been done for five structural elements, namely slab,
beam, column, foundation and staircase.
5.2.5. Foundation
The minimum and maximum spacing should be as in slabs: 0.12%, for Fe500. If the
column bars are bent and properly extended into the footing such bars can also be
considered to act with the footing. The maximum spacing is 3d or 300mm whichever
is less. The steel required in both directions should be distributed uniformly across the
full width of the footing. Individual footings are small sized members with heavy
moments. The sizes of the bars selected should be small enough to develop the full
development length in the available dimension of the footing. Thus, the anchorage
length Ld required, for the sizes of the bars selected for the long and short direction,
should be less than one-half of the lengths for the footing in the respective directions.
52
5.3 Ductility And Ductile Detailing
A ductile material is the one that can undergo larder strains while resisting
loads. When applied to reinforced concrete members and structures, the term
ductility implies the ability to sustain significant in-elastic deformations prior to
collapse. It is the ratio of absolute maximum deformation or curvature or
rotation to the corresponding yield deformation. Under reinforced section shows
ductile deformation whereas over reinforced section shows brittle deformation,
so, ORS should be avoided while designing structural elements.
53
b. If a structure is ductile, its occupant will have sufficient warning of the
impending failure thus reducing the probability of loss of life in the event of
collapse.
c. The limit state design procedure assumes that all the critical section in the
structure will reach their maximum capacities at design load for the structure.
For this to occur, all joints and splices must be able to withstand forces and
deformations corresponding to yielding of the reinforcement.
Selection of cross-section having adequate strength is rather easy but it’s more
difficult to achieve desired strength as well as ductility. For this the designer should
pay attention to detailing of reinforcement, bar cut-offs, splicing and joint details.
Sufficient ductility can be ensured by following certain simple design details:
a. The structural layout should be simple and regular avoiding offsets of beam to
columns, or offsets of column from floor to floor. Changes in stiffness should
be gradual from floor to floor.
b. The amount of tensile reinforcement in beams should be restricted and more
compression reinforcement should be provided. The later should be enclosed
by stirrups to prevent it from buckling.
c. Beams and columns in a reinforced concrete frame should be designed in such
a manner that inelasticity is confined to beams only and column remains
elastic. To ensure this,
54
shear exceeds the strength in flexure and thus prevent from non-ductile failure.
e. Splices and anchorages must be sufficient to prevent bond failures.
f. Beam-column connections should be made monolithic.
g. The reversal of stresses in beam and column due to reversal of earthquake
force must be taken into account in the design by appropriate reinforcement.
At least two bars should be provided continuously both at top and bottom.
The positive moment resistance at the face of a joint should not be less than
one-half of the negative moment resistance provided at that face of the joint.
Neither the negative nor the positive moment resistance at any section along
the member length should be less than one-fourth of the maximum moment
resistance provided at the face of either joint.
The code is silent regarding the design of beam-column joints. A joint should
maintain its integrity in the core for smooth transfer of stress and should be designed
so that it is stronger than the members framing into it. Failure should not occur within
the joint. In fact, failure due to over loading should occur in beams through large
flexural cracking and plastic hinging but not in columns.
The joint shear causes diagonal tension and compression in the joint. With each
reversal of seismic loading, the joint shear changes sign causing cracks due to
diagonal tension in both directions. Moreover, the nature of bond stress also changes
55
in the joint around the beam and column reinforcement. It causes splitting stresses in
the concrete around the bar.
Quite often, the beam-column joint is under a severe congestion of reinforcement due
to too many bars converging within the limited space of the joint. By selecting little
larger concrete area and lower reinforcement percentage, it is possible to avoid
congestion of steel.
The earthquake force acts through center of mass and is resisted by the building
through its center of rigidity. This leads to horizontal twisting of building and is called
torsion. The floor generally rotates as a rigid body. The magnitude of the torsional
moment depends on the distance between center of mass and center of rigidity which
is referred as eccentricity.
A reinforcing bar must be surrounded by concrete for the following principle reasons:
56
To develop the desired strength of a bar by ensuring proper bond between
concrete and steel through-out its perimeter.
To provide protection against corrosion and fire.
For economy:
If a member is longer and the available bars are shorter or vice versa, a joint
or curtailment becomes necessary.
The factors that influence the fire resistance of concrete elements are as follows:
Clause 26.4.3 IS 456-2000 gives nominal cover to meet specified period of fire
resistance.
58
6. DISCUSSION AND CONCLUSION
There are all-together 20 combinations among which Combo 1 and 2 don’t include
seismic considerations. During our analysis, we found out seismic considerations
considerably increase the values of bending moment and shear forces and this is
encountered in the structural elements. Bending moment and shear, being important in
designing of such member (esp. beam and column) should be justified by addressing
such increases esp. in terms of providing steel areas.
ETABS is widely used structural analysis software. Main benefits of using such
software are that they make analysis easy and fast. But great care should be given
during input of data, because degree to which we obtain correct output depends upon
degree to which we input values in computer (GIGO).
After input of data/ loads, analysis is performed in ETABS. To be sure that all loads
are input correctly in ETABS or any other analysis tool, a simple check can be done.
59
For this, total summation of un-factored base reactions must be close to building
weight calculated during preliminary design. If it’s within tolerance limit, we can be
sure input data are correct and can perform further design.
A careful study of frequencies and mode shape may give an idea of correctness of
input data. There is a need to very carefully interpret the computer results of complete
frame analysis tagging into account the sequence of construction.
Cantilever in buildings are used for projection purposes such as in balconies in which
one end is supported and next has free end. Cantilever slabs are those transferring
loads by cantilever action.
During analysis of our models with cantilever slab and with-out them, it was found
out that in models with cantilever slab, rebar percentage was more than that in without
them. It also played significant role in increasing eccentricity and hence torsion in
buildings. Moreover, difference in percentage of rebar in these models decreased as
structural element near stiffness was compared. From it, we can conclude that use of
cantilever projections should be minimized as far as possible.
In static analysis, only one mode is considered and its modal time period is longest
one. It considers building shows only one modal shape in action of lateral forces. In
this static analysis, though having longest time period, 90% of total seismic mass may
not have participated during earthquake. Hence design may not be accurate or more
precisely, structure may be less earthquake resistant.
60
Static Base shear, Vbsx = KN
Static Base shear, Vbsy = KN
Dynamic Base shear, Vbdx = KN
Dynamic Base shear, Vbdy = KN
The major advantage of using the forces obtained from a dynamic analysis as the
basis for a structural design is that the vertical distribution of forces may be
significantly different from the forces obtained from an equivalent static load analysis.
Consequently, the use of dynamic analysis will produce structural designs that are
more earthquake resistant than structures designed using static loads. The current code
allows the results obtained from a dynamic analysis to be normalized so that the
maximum dynamic base shear is equal to the base shear obtained from a simple two-
dimensional static load analysis.
6.6. Drift
Below table shows maximum drift obtained in X and Y directions; which are less
than drift limitation of 0.004 times storey height i.e. 0.013412 in our case which is
necessary to avoid discomfort to occupants and to save non-structural elements from
damage.
The percentage of reinforcement required for columns were found to be less than 6%
which is allowed by IS: 456-2000 which fulfills the condition for design of column
without increasing the grade of concrete.
61
6. CONCLUSION
During the course of this project different problems were encountered and solutions
to these problems were effectively found under the guidance of Supervisor Er. Pujan
Raj Regmi.
The project gave us general idea of how the designs of different structural elements
are carried out and how the detailing for earthquake resistant structure is done. We
hope this project report will help others to understand basic behavior of structure
under the action of earthquake and also the procedure required for the safe design of
such structure.
62
7. BIBLIOGRAPHY
REFERENCE BOOKS:
REFERENCE CODES:
63