Professional Documents
Culture Documents
Cantilever Slab GF
Cantilever Slab GF
Cantilever Slab GF
Design by :
Date : 6-Jun-2021
Project : Hessah towers Checked by :
Subject : Cantilever Slab at Ground floor Date :
Slab Identity : P
W
Concrete fc ' = 44 MPa W
Steel Fy = 420 MPa
Concrete Unit Wt. gc = 25.00 kN/m3 L
Span Length L = 1.00 m
Min. Reqd. Th. tmin = 100 mm [ACI 318M-05, Table 9.5(a)] - Span Length/10
Thickness Used h = 300 mm OK
Width b = 1000 mm
Cover to main steel c = 20 mm
Bar Diameter db = 14
Required Spacing S = 280 mm
Summary
Deflection nAs
k d
Period 5 years and more r' = 0.003 ( Compression steel assumed zero )
Time-dependent factor x = 2
Multiplication factor l = 1.75 [ACI 318M-05, 9.5.2.5]
2 ACI 318M-05
Diameter Area
#6 6 28.3
#8 8 50.3
# 10 10 78.5
# 12 12 113
# 14 14 154
# 16 16 201
# 20 20 314
# 25 25 491
# 28 28 616
# 32 32 801
# 40 40 1256
Page of
GULF CONSULT Design by : Dana
Date : 6-Jun-2021
Project : Checked by :
Subject : Design of Cantilever Slab Date :
f = 0.9
fc' = 44 MPa
fy = 420 MPa
bt = 0.75
b = 1000 mm
d = 273 mm
rmax = 0.03244
Rho Max
0.003
max
C
d
0.004
0.003 0.004
Cmax = d - Cmax
0.003
Cmax = * (d - Cmax)
0.004
Cmax = 3/7 d
As
= 0.85 * (3/7) * (fc'/Fy) * bt
b*d