Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Isolation Valve RSK

A passive device for isolating dust explosions.


Certification according to 94/9/EC
In event of a dust explosion in a filter/dust collector, the explosion can travel back via the inlet
ductwork to connected machinery or other plant equipment. Should an explosion be allowed to
travel back to the plant, the explosion will gain significant speed and will cause catastrophic
damage and can be life threatening to personanel in the plant.
Ignition sources such as ember or sparks can be produced by process machinery and then be
transported to filters. Filters can produce optimum conditions for dust explosions. The likelihood of
an ignition source together with an optimum airborne dust concentration characterises filters / dust
collectors as high-risk zones for dust explosions to occur.
Correctly designed and certified Explosion Vents in filters will protect their integrity, however an un-
isolated filter inlet duct will allow a high-risk hazard to propagate back to the rest of the plant.
Plant managers concerned about occupational Health and Safety as well as plant protection now
have a cost effective opportunity for explosion isolation of filters compared to other products such
as chemical suppression barriers, diverters and knife gate valves.
With a certified BRILEX RSK Isolation Valve it is now possible to isolate filters and run the plant
economically.

BRILEX Gesellschaft für Explosionsschutz mbH · Hinterm Gallberg 15 - 17 · D - 59929 Brilon


Telefon (0 29 61) 96629-0 · Telefax : 96629-99 · info@brilex.de Ust.- IdNr.: DE 161 562 004
HRB 478 · Geschäftsführer : Martin Bunse · Gerichtsstand ist das Amtsgericht Brilon
Bankverbindungen : Volksbank Thülen (BLZ 40 069 371) KTO 4 000 340 900
Technical Datas

Type DN A B Weight Pressure Drop [Pa]


[kg] @ v = 10-30 m/s
RSK 160 160 500 246 28 200
RSK 200 200 540 286 31 200
RSK 250 250 590 336 36 200
RSK 280 280 620 366 38 210
RSK 315 315 660 401 42 260
RSK 355 355 700 441 50 310
RSK 400 400 740 486 65 360
RSK 450 450 790 536 88 410
RSK 500 500 840 586 103 460
RSK 560 560 900 646 118 490
RSK 600 600 940 686 138 500
RSK 630 630 970 716 152 520
RSK 710 710 1050 796 195 555
RSK 800 800 1140 886 252 575
RSK 900 900 1240 986 326 585
RSK 1000 1000 1340 1086 370 600

BRILEX Gesellschaft für Explosionsschutz mbH · Hinterm Gallberg 15 - 17 · D - 59929 Brilon


Telefon (0 29 61) 96629-0 · Telefax : 96629-99 · info@brilex.de Ust.- IdNr.: DE 161 562 004
HRB 478 · Geschäftsführer : Martin Bunse · Gerichtsstand ist das Amtsgericht Brilon
Bankverbindungen : Volksbank Thülen (BLZ 40 069 371) KTO 4 000 340 900
Flange Dimensions:

Type / DN OD Ø ID Ø BHC Ø s Hole Ø N Holes


RSK 160 215 165 195 5 9.5 6
RSK 200 255 205 235 5 9.5 6
RSK 250 305 255 285 5 9.5 6
RSK 280 335 285 315 5 9.5 8
RSK 315 380 320 354 5 9.5 8
RSK 355 420 360 394 5 9.5 8
RSK 400 465 405 439 5 9.5 12
RSK 450 515 455 489 5 9.5 12
RSK 500 565 505 539 5 9.5 12
RSK 560 635 565 601 6 9.5 12
RSK 600 675 605 641 6 9.5 16
RSK 630 705 635 671 6 9.5 16
RSK 710 795 715 751 8 11.5 16
RSK 800 885 805 841 8 11.5 16
RSK 900 985 905 941 8 11.5 16
RSK 1000 1085 1005 1041 8 11.5 16

Flanges acc. to DIN 24 154 R 2, R 3, R 4 and R 5


available as option + 5% extra.

Gap between e.g. filter and valve:

Type Distance pmax Kstmax


RSK 160 2.0 m 2.2 bar ü 300 bar · m · s-1
RSK 200 2.0 m 2.2 bar ü 300 bar · m · s-1
RSK 250 2.0 m 2.2 bar ü 300 bar · m · s-1
RSK 280 2.0 m 2.2 bar ü 300 bar · m · s-1
RSK 315 2.0 m 2.2 bar ü 300 bar · m · s-1
RSK 355 2.0 m 2.2 bar ü 300 bar · m · s-1
RSK 400 2.0 m 2.2 bar ü 300 bar · m · s-1
RSK 450 3.0 m 1.4 bar ü 300 bar · m · s-1
RSK 500 3.0 m 1.4 bar ü 300 bar · m · s-1
RSK 560 3.0 m 1.4 bar ü 300 bar · m · s-1
RSK 600 3.0 m 1.4 bar ü 300 bar · m · s-1
RSK 630 3.0 m 1.4 bar ü 300 bar · m · s-1
RSK 710 3.0 m 1.4 bar ü 300 bar · m · s-1
RSK 800 3.0 m 1.4 bar ü 300 bar · m · s-1
RSK 900 3.0 m 1.4 bar ü 300 bar · m · s-1
RSK 1000 3.0 m 1.4 bar ü 300 bar · m · s-1

Distance: Distance
Pred max: Maximum reduced explosion overpressure
KSt max.: Kst-Value (Dust Explosion Class St1 + ST2)

BRILEX Gesellschaft für Explosionsschutz mbH · Hinterm Gallberg 15 - 17 · D - 59929 Brilon


Telefon (0 29 61) 96629-0 · Telefax : 96629-99 · info@brilex.de Ust.- IdNr.: DE 161 562 004
HRB 478 · Geschäftsführer : Martin Bunse · Gerichtsstand ist das Amtsgericht Brilon
Bankverbindungen : Volksbank Thülen (BLZ 40 069 371) KTO 4 000 340 900