Professional Documents
Culture Documents
Portable Generator: 15000 Starting Watts / 12000 Running Watts Electric Start
Portable Generator: 15000 Starting Watts / 12000 Running Watts Electric Start
Th
O
ty
T
ar
15000 Starting Watts / 12000 Running Watts ra ra
Ga
os
Ga
añ
os
ñ añ
G
a na n tí
o
n tí a n tí
li m it a d a d e u a li m os a li m es
it a d a d e d it a d a d e tr
Electric start
r Limited Warr r Limited Warra Year
Limited Wa
PORTABLE GENERATOR
Yea an Yea rra
ne t wo
nt ree n
y
y
Th
O
ty
T
Ga ra ar
Ga
a
ns
n a
ns
ran a n ti a n ti
tie li m it é e d’u n e li m ux e li m ois
ité e d e d e ité e d e tr
100111
y
y
Th
O
ty
T
G ar an tía li m it ad
de deu x ans
d e tr ois a n s
G a r a n tía li m it a
G a r a n tía li m it a
d ’u n a n
it é e
té e
té e
im
de ed de
da
da
ad
li li
mi
mi
ti
el
un an os ie un ie
año G ar año s G ar ant año G ar ant
12039 Smith Ave.
SAVE THESE INSTRUCTIONS Santa Fe Springs CA 90670
r Limited Warr r Limited Warra Year
Limited Wa
Important
ne
Yea ansafety instructions
t wo
Yea nt ree
rra
n MADE IN CHINA USA / 1-877-338-0999
are included in this manual. REV 100111-20190527 www.championpowerequipment.com
Th
O
y
y
ty
T
AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to
40°C (104°F). When your product is needed your product may be operated at temperatures ranging from -15°C (5°F) to
50°C (122°F) for short periods. If the product is exposed to temperatures outside this range during storage, it should be
brought back within this range before operation. In any event, the product must always be operated outdoors, in a
well-ventilated area and away from doors, windows and other vents.
– or –
Call our Customer Care Team Toll-Free at:
1-877-338-0999
Parts Ordering:
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)
Toll Free: 1-877-338-0999
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover.
100111
Every effort has been made to ensure the accuracy and completeness of the information in this manual, and we
reserve the right to change, alter and/or improve the product and this document at any time without prior notice.
Since CPE/CET highly value how our products are designed, manufactured, operated and are serviced, and also
highly value your safety and the safety of others, we would like you to take the time to review this product manual
and other product materials thoroughly and be fully aware and knowledgeable of the assembly, operation, dangers
and maintenance of the product before use. Fully familiarize yourself, and make sure others who plan on operating
the product fully familiarize themselves too, with the proper safety and operation procedures before each use. Please
always exercise common sense and always error on the side of caution when operating the product to ensure no
accidents, property damage, or injury occurs. We want you to continue to use and be satisfied with your CPE/CET
product for years to come.
Record the model and serial numbers as well as date and place of purchase for future reference. Have this
information available when ordering parts and when making technical or warranty inquiries.
1-877-338-0999
Model Number
100111
Serial Number
Date of Purchase
Purchase Location
For Oil Type see ‘Add Engine Oil‘ section. For Fuel Type see ‘Add Fuel‘ section.
1
100111 ENGLISH
Manual Conventions
This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol
is used with a key word to alert you to potential hazards in operating and owning power equipment.
Follow all safety messages to avoid or reduce the risk of serious injury or death.
DANGER CAUTION
DANGER indicates an imminently hazardous CAUTION used without the safety alert symbol
situation which, if not avoided, will result in death indicates a potentially hazardous situation which, if
or serious injury. not avoided, may result in property damage.
WARNING NOTE
If you have questions regarding your generator, we can
WARNING indicates a potentially hazardous
help. Please call our help line at 1-877-338-0999
situation which, if not avoided, could result in
death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous
situation which, if not avoided, may result in minor
or moderate injury.
2
ENGLISH 100111
Safety Rules
WARNING DANGER
Read this manual thoroughly before operating your Generator produces powerful voltage.
generator. Failure to follow instructions could result
DO NOT touch bare wires or receptacles.
in serious injury or death.
DO NOT use electrical cords that are worn, damaged
or frayed.
DO NOT operate generator in wet weather.
WARNING DO NOT allow children or unqualified persons to
operate or service the generator
Use a ground fault circuit interrupter (GFCI) in damp
Cancer and Reproductive Harm –
areas and areas containing conductive material such
www.P65Warnings.ca.gov as metal decking.
Use approved transfer equipment to isolate generator
from your electric utility and notify your utility
DANGER company before connecting your generator to your
power system.
Generator exhaust contains carbon monoxide, a
colorless, odorless, poison gas. Breathing carbon
monoxide will cause nausea, dizziness, fainting or WARNING
death. If you start to feel dizzy or weak, get to fresh Sparks can result in fire or electrical shock.
air immediately.
When servicing the generator:
Operate generator outdoors only in a well ventilated Disconnect the spark plug wire and place it where it
cannot contact the plug.
area.
DO NOT check for spark with the plug removed.
DO NOT operate the generator inside any building, Use only approved spark plug testers.
including garages, basements, crawlspaces and
sheds, enclosure or compartment, including the
generator compartment of a recreational vehicle. WARNING
DO NOT allow exhaust fumes to enter a confined
Running engines produce heat. Severe burns can
area through windows, doors, vents or other
occur on contact.
openings. Combustible material can catch fire on contact.
DANGER CARBON MONOXIDE: using a generator
indoors CAN KILL YOU IN MINUTES. DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching.
Maintain at least 3 ft. (91.4 cm) of clearance on all
DANGER sides to ensure adequate cooling.
Maintain at least 5 ft. (1.5 m) of clearance from
Rotating parts can entangle hands, feet, hair, combustible materials.
clothing and/or accessories.
Traumatic amputation or severe laceration can result.
WARNING
Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry. Medical and Life Support Uses.
Operate equipment with guards in place. In case of emergency, call 911 immediately.
DO NOT wear loose-fitting clothing, dangling NEVER use this product to power life support
drawstrings or items that could become caught. devices or life support appliances.
NEVER use this product to power medical devices
or medical appliances.
Inform your electricity provider immediately if you
or anyone in your household depends on electrical
equipment to live.
Inform your electrical provider immediately if a
loss of power would cause you or anyone in your
household to experience a medical emergency.
3
100111 ENGLISH
Safety Rules
DANGER CAUTION
Fuel and fuel vapors are highly flammable and Exceeding the generator’s running capacity can
extremely explosive. damage the generator and/or electrical devices
Fire or explosion can cause severe burns or death. connected to it.
Unintentional startup can result in entanglement,
traumatic amputation or laceration. DO NOT overload the generator.
Start the generator and allow the engine to stabilize
When adding or removing fuel: before connecting electrical loads.
Turn the generator off and let it cool for at least two Connect electrical equipment in the off position,
and then turn them on for operation.
minutes before removing the fuel cap. Loosen the
Turn electrical equipment off before stopping the
cap slowly to relieve pressure in the tank.
generator.
Only fill or drain fuel outdoors in a well-ventilated area. DO NOT tamper with the governed speed.
DO NOT pump gas directly into the generator at the DO NOT modify the generator in any way.
gas station. Use an approved container to transfer
the fuel to the generator.
DO NOT overfill the fuel tank. CAUTION
Always keep fuel away from sparks, open flames, Improper treatment or use of the generator can
pilot lights, heat and other sources of ignition. damage it, shorten its life and void your warranty.
DO NOT light or smoke cigarettes.
Use the generator only for intended uses.
When starting the generator:
Operate only on level surfaces.
DO NOT attempt to start a damaged generator. DO NOT expose generator to excessive moisture,
Make certain that the gas cap, air filter, spark plug, dust, or dirt.
fuel lines and exhaust system are properly in place. DO NOT allow any material to block the cooling slots.
Allow spilled fuel to evaporate fully before If connected devices overheat, turn them off and
attempting to start the engine. disconnect them from the generator.
DO NOT use the generator if:
Make certain that the generator is resting firmly on
–– Electrical output is lost
level ground. –– Equipment sparks, smokes or emits flames
When operating the generator: –– Equipment vibrates excessively
DO NOT move or tip the generator during operation.
DO NOT tip the generator or allow fuel or oil to spill.
WARNING
When transporting or servicing the generator:
Lift bar is designed to carry ONLY the weight of the
Make certain that the fuel shutoff valve is in the off
generator.
position and the fuel tank is empty.
Disconnect the spark plug wires. DO NOT overload the lift bar. DO NOT place
If generator has been running, allow to cool before anything on top of, in the frame of, or attach to
transporting or servicing. the generator prior to lifting. Stand clear when
generator is lifted off the ground. Do not stand,
When storing the generator: walk or pass under the generator, or allow anyone
Store away from sparks, open flames, pilot lights, to pass under it when lifting. A falling generator
heat and other sources of ignition. If generator has can result in bodily injury, death, and/or property
been running, allow to cool before storing. damage. DO NOT lift while the generator is running.
Unplug all items from power panel before lifting.
Lift using a lift strap or hook through the holes in
the lift bar. DO NOT attempt to refuel or perform
any maintenance while the generator is in the air at
any height.
4
ENGLISH 100111
Safety Rules
D E F
A B C
1035-L-SF-B
and engine components required. The operator should contact local fire agencies for compnonentes del motor están sea necesario. El operador debe comunicarse con las agencias locales de et les pièces du moteur sont doit communiquer avec le service d’incendie local pour connaître les
are extremely HOT and laws and regulations relating to fire prevention requirements. extremadamente CALIENTES y bomberos para las leyes y reglamentos relativos a los requisitos de prevención extrêmement CHAUDS et lois et les règlements en matière de prévention des incendies. Si elle
cause burns. If installed, clean every 100 hours or every season. causan quemaduras. de incendios. Si está instalado, limpie cada 100 horas o cada temporada. peuvent causer des brûlures. est installée, nettoyez toutes les 100 heures ou chaque saison.
Rev B
B
Artwork Notes Revision Changes
CAUTION PRECAUCIÓN MISE EN GARDE 3mm corner radius; 2mm safe margin ---
A transfer switch MUST be used Es OBLIGATORIO usar un interruptor de Le commutateur de transfert DOIT être
GN-SF-T-002.1
when connecting generator to a transferencia cuando se conecte el generador utilisé pour connecter la génératrice
This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for
building’s electrical system. al sistema eléctrico de un inmueble. Vea el au système électrique
outsided’un
partiesimmeuble.
without the explicit consent of Champion Power Equipment.
109 158 x 23 mm
BLACK
C DANGER
FOR USE IN A WEATHER-PROTECTED AREA ONLY.
PELIGRO
PARA USO EN AREAS DESPEJADAS SOLAMENTE.
DANGER
EMPLOYEZ UNIQUEMENT DANS UN EMPLACEMENT A
GN-SF-T-005D.1
DO NOT EXPOSE TO RAIN. NO EXPONGA A LA LLUVIA. L’ABRI DES INTEMPÉRIES. NE PAS EXPOSER À LA PLUIE.
WHEN STORING GASOLINE, PROPANE (LPG) OR CUANDO ALMACENE GASOLINA, GAS PROPANO LORSQUE VOUS RANGEZ DE L’ESSENCE, DU GAZ
EQUIPMENT WITH FUEL IN IT: Store away from (GLP) O EQUIPO CON COMBUSTIBLE ADENTRO: PÉTROLE LIQUÉFIÉ (GPL) OU DU MATÉRIEL
furnaces, stoves, water heaters or other appliances that Almacene fuera de hornos, estufas, calentones de agua, CONTENANT DE L’ESSENCE : Rangez-les à l’écart des
have a pilot light or other ignition source because they o otros aparatos que tengan luz piloto o otra fuente de appareils de chauffage, des chauffe-eau et des autres
can ignite the fuel. encendido por que pueden encender el combustible. dispositifs qui contiennent une veilleuse ou une autre
source d’allumage parce qu’il peut enflammer l’essence.
Gasoline and propane (LPG) are extrememely La gasolina y el gas propano (GLP) son extremada- L’essence et le propane (GPL) sont extrêmement
flammable. Check for spilled fuel or fuel mente inflamables. Verifique si hay combustible inflammables. Vérifiez la présence de carburant renversé et
leaks. If one is found, shut off fuel supply and derramado o fugas de combustible. Si una es de fuite de carburant. Si vous en trouvez, coupez la source
stop engine immediately. Allow to cool at encontrada, apague el suministro y pare el motor d’alimentation en carburant et arrêtez le moteur
least 2 minutes before refueling. inmediatamente. Permita que se enfrié por los menos 2 immédiatement. Laissez-le refroidir au moins 2 minutes
minutos antes de reabastecerlo. avant de remettre du carburant.
Operating of this equipment may create La operación de este equipo puede originar chispas que Le fonctionnement de cet équipement peut générer des
sparks that can start fires around dry pueden crear incendios cerca de la vegetación seca. Es étincelles et causer un incendie près de la végétation
vegetation. A spark arrester may be required. posible que se requiera un parachispas. El operador sèche. Un pare-étincelles peut être nécessaire.
The operator should contact local fire deberá comunicarse con los organismos locales L'opérateur devrait communiquer avec les agences
agencies for laws or regulations relating to fire encargados de combatir incendios para conocer las leyes locales pour connaître les règles et règlements de
prevention requirements. o reglamentos relacionados con los requisitos para prévention des incendies.
prevenir incendios.
ACE
MINIM E El uso de un generador en interiores PUEDE MATARLO EN MINUTOS.
El escape del generador contiene monóxido de carbono.
SP U
1,5M
5FM CTLEARANCE
5 This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for
outside parties without the explicit consent of Champion Power Equipment.
100111 ENGLISH
Controls and Features
Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the
controls and features. Save this manual for future reference.
Generator
4 5 9
2 3 6 7
(1) Spark Plug Arrester and Muffler (7) Fuel Valve – Used to turn fuel supply on and off to
(2) Oil Filter engine.
(4) Engine Access Cover (9) Fuel Tank – 10.9 gallon (41.2 L) capacity fuel
tank.
(5) Power Panel – See “Power Panel” section.
(6) Battery – Used to start the engine.
6
ENGLISH 100111
Controls and Features
Power Panel
1 2 3 4 5 6
A B
7 8 9 10
(1) Ignition Switch – Press the switch to the “START” (6) Circuit Breakers – Protects the generator against
position to start the generator. Flip to the “OFF” electrical overloads.
position to turn off the generator. (7) 120/240 Volt AC / 30 Amp Twist-Lock Receptacle
(2) 120/240 Volt AC / 50 Amp Receptacle (NEMA L14-30R) – May be used to supply
(NEMA 14-50R) – May be used to supply electrical electrical power for the operation of 120 and/or
power for the operation of 120 and/or 240 Volt 240 Volt AC, single phase 60 Hz electrical loads.
AC, single phase 60 Hz electrical loads. (8) 120 Volt AC / 30 Amp Twist-Lock Receptacle
(3) Choke – Used to start the engine. (NEMA L5-30R) – May be used to supply electrical
(4) Intelligauge – Cycles through four modes power for the operation of 120 Volt AC, single
displaying voltage, frequency, running time, and phase 60 Hz electrical loads.
total time for approximately five seconds each. (9) 120 Volt AC / 20 Amp Duplex (2)
If an over-voltage condition occurs, the display (GFCI 5-20R) – May be used to supply electrical
will only show the voltage and will be blinking. power for the operation of 120 Volt AC, single
If the voltage continues to rise, the display will phase 60 Hz electrical loads.
blink “EEEE”. The generator is to be shut off (10) Ground Terminal – Consult an electrician for local
immediately in an over-voltage condition. grounding regulations.
(5) Power Meter – Displays the generator’s output in
reference to its rated wattage. The greater the
output the more LED’s illuminate. The LED bars
will light up from green to orange. If the orange
LEDs light up, the generator is overloaded. Stop
use of equipment and disconnect immediately
to stop overloading. DO NOT OVERLOAD THE
GENERATOR.
7
100111 ENGLISH
Controls and Features
Parts Included
Your 100111 gasoline powered enerator ships with the
following parts:
Wheel Kit
–– 12 in. Wheel . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
–– Pin Roll Ø16 x Ø12 x 116 (for Wheel). . . . . . . . . . . 2
–– “R” Shape Pin . . . . . . . . . . . . . . . . . . . . . . . . . . 2
–– Washer Ø12 . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Other
–– Oil Funnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
–– Engine Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
–– Flange bolt M5x12 for battery. . . . . . . . . . . . . . . . 2
–– Flange lock nut M5. . . . . . . . . . . . . . . . . . . . . . . 2
8
ENGLISH 100111
Assembly
Your generator requires some assembly. This unit ships Install the Wheel Kit Cont’d.
from our factory without oil or fuel. It must be properly 7. Repeat steps 2-5 to attach the second wheel.
serviced with fuel and oil before operation. 8. Remove wooden blocks from behind the support leg.
If you have any questions regarding the assembly of your
generator, call our help line at 1-877-338-0999. Please
have your serial number and model number available.
9
100111 ENGLISH
Assembly
Add Engine Oil Add Engine Oil Cont’d.
CAUTION CAUTION
DO NOT attempt to crank or start the engine before The engine is equipped with a low oil shut-off and
it has been properly filled with the recommended will stop when the oil level in the crankcase falls
type and amount of oil. Damage to the generator as below the threshold level.
a result of failure to follow these instructions will
void your warranty.
NOTE
Check oil often during the break-in period. Refer to the
NOTE Maintenance section for recommended service intervals.
The recommended oil type is 10W-30 automotive oil.
NOTE
We consider the first 5 hours of run time to be
D the break-in period for the unit. During the break
in period stay at or below 50% of the running
B
watt rating and vary the load occasionally to allow
stator windings to heat and cool. Adjusting the
3. Remove oil fill cap by rotating ¼ turn load will also cause engine speed to vary and help
counterclockwise (B). seat piston rings. After the 5 hour break-in period,
change the oil.
4. Using funnel fill to full mark on dipstick. DO NOT
OVERFILL.
Degrees Celsiusº (Outside)
Volume for first use or oil change without oil filter
change: 1.1 qt.(1 L).
Volume after oil and oil filter change: 1.4 qt.(1.3 L). Full Synthetic 5W-30
5. Check engine oil level on dipstick (D). Add as
needed. DO NOT OVERFILL.
NOTE
Using synthetic oil does not increase the
recommended oil change interval. Full synthetic
6. Replace oil fill cap by rotating ¼ turn clockwise. 5W-30 oil will aid in starting in cold ambient
7. Close engine access cover. <5ºC (41ºF) temperatures.
10
ENGLISH 100111
Assembly
Add Fuel Add Fuel Cont’d.
1. Use clean, fresh, regular unleaded fuel with a
minimum octane rating of 85 and an ethanol content NOTE
of less than 10% by volume. Champion engines work well with 10% or less
2. DO NOT mix oil with fuel. ethanol blend fuels. When using blended fuels there
3. Clean the area around the fuel cap. are some issues worth noting:
4. Remove the fuel cap. –– Ethanol-gasoline blends can absorb more water
5. Slowly add fuel to the tank. DO NOT OVERFILL. than gasoline alone.
Fuel can expand after filling. A minimum of ¼ in. –– These blends can eventually separate, leaving
(6.4 mm) of space left in the tank is required water or a watery goo in the tank, fuel valve and
for fuel expansion, more than ¼ in. (6.4 mm) is carburetor.
recommended. Fuel can be forced out of the tank as –– With gravity-fed fuel supplies, this compromised
a result of expansion if it is overfilled, and can affect fuel can be drawn into the carburetor and cause
the stable running condition of the product. When damage to the engine and/or potential hazards.
filling the tank, it is recommended to leave enough –– There are only a few suppliers of fuel stabilizer
space for the fuel to expand. that are formulated to work with ethanol blend
fuels.
–– Any damages or hazards caused by using
improper fuel, improperly stored fuel, and/
or improperly formulated stabilizers, are not
covered by manufacture’s warranty.
It is advisable to always shut off the fuel supply,
run the engine to fuel starvation and drain the tank
when the equipment is not in use for more than 30
days.
6. Screw on the fuel cap and wipe away any spilled fuel.
Grounding
CAUTION Your generator must be properly connected to an
appropriate ground to help prevent electric shock.
Use regular unleaded gasoline with a minimum
octane rating of 85.
WARNING
Do not mix oil and gasoline. Failure to properly ground the generator can result
Fill tank to approximately ¼ in. (6.4 mm) below the in electric shock.
top of the tank to allow for fuel expansion.
DO NOT pump gas directly into the generator at the A ground terminal connected to the frame of the generator
gas station. Use an approved container to transfer
has been provided on the power panel. For remote
the fuel to the generator.
grounding, connect of a length of heavy gauge
DO NOT fill fuel tank indoors.
DO NOT fill fuel tank when the engine is running or hot. (12 AWG minimum) copper wire between the generator
DO NOT overfill the fuel tank. ground terminal and a copper rod driven into the ground.
DO NOT light cigarettes or smoke when filling the We strongly recommend that you consult with a qualified
fuel tank. electrician to ensure compliance with local electrical codes.
WARNING
Pouring fuel too fast through the fuel screen may
result in blow back of fuel at the operator while filling.
11
100111 ENGLISH
Operation
Generator Location Grounding
NEVER operate the generator inside any building, The generator system ground connects the frame to the
including garages, basements, crawlspaces and sheds, ground terminals on the power panel. The system ground is
enclosure or compartment, including the generator connected to the AC neutral wire.
compartment of a recreational vehicle. Please consult
your local authority. In some areas, generators must Surge Protection
be registered with the local utility. Generators used at
construction sites may be subject to additional rules and CAUTION
regulations. Generators should be on a flat, level surface
at all times. (Even while not in operation) Generators Voltage fluctuation may impair the proper
must have at least 5 ft. (1.5 m) of clearance from all functioning of sensitive electronic equipment.
combustible material. In addition to clearance from
Electronic devices, including computers and many
all combustible material, generators must also have
programmable appliances use components that are
at least 3 ft. (91.4 cm) of clearance on all sides to
designed to operate within a narrow voltage range and
allow for adequate cooling, maintenance and servicing.
may be affected by momentary voltage fluctuations.
Generators should never be started or operated in the
While there is no way to prevent voltage fluctuations, you
back of a SUV, camper, trailer, in the bed of a truck
can take steps to protect sensitive electronic equipment.
(regular, flat or otherwise), under staircases/stairwells,
1. Install UL1449, CSA-listed, plug-in surge suppressors
next to walls or buildings, or in any other location that
on the outlets feeding your sensitive equipment.
will not allow for adequate cooling of the generator
Surge suppressors come in single- or multi-outlet
and/or the muffler. DO NOT contain generators during
styles. They’re designed to protect against virtually
operation. Allow generators to properly cool before
all short-duration voltage fluctuations.
transport or storage.
Place the generator in a well-ventilated area. DO NOT
place the generator near vents or intakes where exhaust
Starting the Engine
1. Make certain the generator is on a flat, level surface.
fumes could be drawn into occupied or confined
2. Disconnect all electrical loads from the generator.
spaces. Carefully consider wind and air currents when
Never start or stop the generator with electrical
positioning generator.
devices plugged in or turned on.
Failure to follow proper safety precautions may void
3. Turn the fuel valve to the “ON” position.
manufacturer’s warranty.
4. Pull the choke knob out.
5. Flip the ignition switch to the “ON” position.
WARNING 6. Press and hold the ignition switch to the “START”
position. Release as the engine begins to roll over. If
Do not operate or store the generator in rain, snow,
the engine fails to start within five seconds, release
or wet weather.
the switch and wait at least ten seconds before
Using a generator or electrical appliance in wet attempting to start the engine again.
conditions, such as rain or snow, or near a pool or 7. Do not over-choke. As soon as engine starts, push the
sprinkler system, or when your hands are wet, could
choke knob in.
result in electrocution.
WARNING
During operation the muffler and exhaust fumes
produced will become hot. If adequate cooling and
breathing space are not supplied, or if the generator
is blocked or contained, temperatures can become
extremely heated and may lead to fire.
12
ENGLISH 100111
Operation
Starting the Engine Cont’d. Connecting Electrical Loads Cont’d.
NOTE NOTE
Keep choke knob pulled out for only 1 push of Connecting a generator to your electric utility company’s
the ignition switch. After first push, press knob in power lines or to another power source may be against
for up to the next 3 pushes of the ignition switch. the law. In addition this action, if done incorrectly, could
Too much choke leads to sparkplug fouling/engine damage your generator and appliances and could cause
flooding due to the lack of incoming air. This will serious injury or even death to you or a utility worker
cause the engine not to start. who may be working on nearby power lines. If you plan
to run a portable electric generator during an outage,
please notify your electric utility company immediately
NOTE and remember to plug your appliances directly into the
If the engine starts but does not run make certain generator. Do not plug the generator into any electric
that the generator is on a flat, level surface. The outlet in your home. Doing so could create a connection
engine is equipped with a low oil sensor that will to the utility company power lines. You are responsible
prevent the engine from running when the oil level for ensuring that your generator’s electricity does not
falls below a critical threshold. feed back into the electric utility power lines.
If the generator will be connected to a building electrical
system, consult your local utility company or a qualified
NOTE electrician. Connections must isolate generator power
from utility power and must comply with all applicable
The supplied 12V 33AH battery does re-charge
laws and codes.
while the engine is running, but it is also
recommended that the battery be fully charged
at least once per month. Stopping the Engine
1. Turn off and unplug all electrical loads. Never start
or stop the generator with electrical devices plugged
Connecting Electrical Loads in or turned on.
1. Let the engine stabilize and warm up for a few 2. Let the generator run at no-load for several minutes
minutes after starting to stabilize internal temperatures of the engine and
2. Plug in and turn on the desired 120/240 Volt AC generator.
single phase, 60 Hz electrical loads. 3. Press the ignition switch to the “OFF” position.
–– DO NOT connect 3-phase loads to the generator. 4. Turn the fuel valve to the “OFF” position.
–– DO NOT connect 50 Hz loads to the generator. Important: Always ensure that the fuel valve and the
–– DO NOT overload the generator. ignition switch are in the “OFF” position when the engine
is not in use.
NOTE
If the engine will not be used for a period of two (2) weeks
or longer, please see the Storage section for proper engine
and fuel storage.
13
100111 ENGLISH
Operation
Do Not Overload Generator Operation at High Altitude
Capacity The density of air at high altitude is lower than at sea
Follow these simple steps to calculate the running and level. Engine power is reduced as the air mass and air-
starting watts necessary for your purposes. fuel ratio decrease. Engine power and generator output
1. Select the electrical devices you plan on running at will be reduced approximately 3½% for every 1000 ft.
the same time. (305 m) feet of elevation above sea level. This is a
2. Total the running watts of these items. This is natural trend and cannot be changed by adjusting the
the amount of power you need to keep your items engine. At high altitudes increased exhaust emissions
running. can also result due to the increased enrichment of the
3. Identify the highest starting wattage of all devices air fuel ratio. Other high altitude issues can include hard
identified in step 1. Add this number to the number starting, increased fuel consumption and spark plug
calculated in step 2. Surge wattage is the extra fouling.
If using this product above the elevation of 5500 ft.
burst of power needed to start some electric driven
(1676 m) Champion Power Equipment suggests ordering
equipment. Following the steps listed under “Power
a high altitude jet kit. Champion Power Equipment
Management” will guarantee that only one device will
can provide a high altitude carburetor jet kit (part no.
be starting at a time.
101131) at an additional cost. The alternative jet kit and
Power Management installation instructions can be obtained by contacting
Use the following formula to convert voltage and Customer Support. Installation instructions are also
amperage to watts: available in the Technical Bulletin area of the Champion
Power Equipment internet site.
Volts x Amps = Watts
To prolong the life of your generator and attached
WARNING
devices, follow these steps to add electrical load:
1. Start the generator with no electrical load attached Operation using the alternative main jet at
2. Allow the engine to run for several minutes to stabilize. elevations lower than the recommended minimum
3. Plug in and turn on the first item. It is best to attach altitude can damage the engine. For operation at
lower elevations, the standard main jet must be
the item with the largest load first.
used. Operating the engine with the wrong engine
4. Allow the engine to stabilize.
configuration at a given altitude may increase
5. Plug in and turn on the next item. its emissions and decrease fuel efficiency and
6. Allow the engine to stabilize. performance.
7. Repeat steps 5-6 for each additional item.
NOTE
Never exceed the specified capacity when adding
loads to the generator.
14
ENGLISH 100111
Operation
GFCI
Your generator is equipped with two (2) Ground Fault
Circuit Interrupter (GFCI) duplexes. In the event of a
ground fault, a GFCI trips automatically to stop the
flow of electricity and prevent serious injury. The green
indicating light on the receptacle will also turn off. Press
the reset button located on the front of the receptacle to
restore flow of electricity. (A) The green indicating light
will also turn back on. GFCI does not protect against
circuit overloads.
WARNING
For the GFCI receptacles to work properly the neutral wire
must be bonded to ground or to the generator frame. Your
Champion generator comes with the neutral wire already
bonded to the frame. If the bonding wire is removed then
the GFCI receptacles will no longer function as designed.
If the neutral bonding wire is removed to accommodate
a transfer switch installation for connection to a house
or building, then the transfer switch must not switch off
the neutral connection to ground within the building.
Champion Power Equipment recommends that you consult
with a licensed, local electrician. Due to the variety of
local codes, we cannot specifically advise you regarding
modifications to the wiring of your portable generator.
15
100111 ENGLISH
Maintenance and Storage
The owner/operator is responsible for all periodic Oil Cont’d.
maintenance.
2. After the oil has completely drained, replace the
WARNING drain bolt.
3. With the oil drained, remove oil filter by turning
Never operate a damaged or defective generator. counterclockwise (B).
4. Apply a light coat of clean engine oil to the gasket
of the new oil filter.
WARNING 5. Screw the new oil filter on (turning clockwise) by
hand until the gasket contacts the engine block.
Tampering with the factory set governor will void 6. Screw the filter an additional ¾ turn.
your warranty. 7. Open engine access cover.
8. Using funnel fill to full mark on dipstick. DO NOT
WARNING OVERFILL.
Volume for first use or oil change without oil filter
Improper maintenance will void your warranty. change: 1.1 qt.(1 L).
Volume after oil and oil filter change: 1.4 qt.(1.3L).
9. Check engine oil level on dipstick. Add oil as
NOTE needed. DO NOT OVERFILL.
Maintenance, replacement, or repair of emission
control devices and systems may be performed
by any non-road engine repair establishment or
individual.
16
ENGLISH 100111
Maintenance and Storage
Spark Plug Cont’d. Cleaning
7. Use the spark plug socket (not included) to firmly
install the plug. CAUTION
8. Attach the spark plug wire to the plug.
DO NOT spray engine with water.
Air Filter
1. Open engine access cover. Water can contaminate the fuel system.
2. Remove the air filter cover by turning the two
fasteners ¼ turn counterclockwise. Use a damp cloth to clean exterior surfaces of the engine.
3. Pull the air filter straight out away from engine. Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris
from the engine.
Adjustments
The air-fuel mixture is not adjustable. Tampering with
the governor can damage your generator and your
electrical devices and will void your warranty. CPE
4. Install new air filter. recommends that you contact our service line at
5. Replace air filter cover and turn the two fasteners ¼ 1-877-338-0999 for all other service and/or adjustment
turn clockwise. needs.
6. Close engine access cover. Maintenance Schedule
Follow the service intervals indicated in the following
Spark Arrester
1. Allow the engine to cool completely before servicing maintenance schedule.
the spark arrester. Service your generator more frequently when operating
2. Remove the two screws holding the cover plate which in adverse conditions.
retains the end of the spark arrester to the muffler. Contact our helpline at 1-877-338-0999 to locate the
3. Remove the spark arrester. nearest Champion Power Equipment certified service
4. Carefully remove the carbon deposits from the spark
dealer for your generator or engine maintenance needs.
arrester with a wire brush.
5. Replace the spark arrester if it is damaged. Every 8 hours or daily
6. Position the spark arrester in the muffler and attach Check oil level
with the two screws. Clean around air intake and muffler
First 5 hours
Change oil and oil filter
17
100111 ENGLISH
Maintenance and Storage
Generator Maintenance Battery Cont’d.
Make certain that the generator is kept clean and stored charger or battery maintainer to keep the battery
properly. Only operate the unit on a flat, level surface in properly charged. If the battery voltage is extremely low,
a clean, dry operating environment. DO NOT expose the the charging circuit may not be able to re-charge the
unit to extreme conditions, excessive dust, dirt, moisture battery. In this case, the battery must be connected to a
or corrosive vapors. standard automotive style battery charger for re-charging
before it can be used.
CAUTION Charge the Battery
DO NOT use a garden hose to clean the generator. For generators equipped with batteries for electric
Water can enter the generator through the cooling starting, proper battery maintenance and storage should
slots and damage the generator windings. be followed. An automatic battery charger (not included)
with automatic trickle charging capability should be used
Use a damp cloth to clean exterior surfaces of the generator. to charge the battery. Maximum charging rate should not
Use a soft bristle brush to remove dirt and oil. exceed 1.5 amps. Follow the instructions included with
Use an air compressor (25 PSI) to clear dirt and debris the battery charger. The battery should be fully charged
from the generator. at least once per month.
Inspect all air vents and cooling slots to ensure that they
are clean and unobstructed. NOTE
A Float Charger will maintain the battery condition
Storage over long storage periods.
The generator should be started at least once every 14
days and allowed to run for at least 20 minutes. For Disconnect the Battery
longer term storage, please follow these guidelines. 1. Remove the protective cover from the black/negative
battery lead.
Generator Storage
2. Disconnect the black/negative lead from the black/
1. Add a properly formulated fuel stabilizer to the tank.
negative terminal on the battery and store the cap
2. Be sure all appliances are disconnected from the
screw (M5x12) and lock washer (M5).
generator.
3. Repeat steps 1-2 for the red/positive battery lead.
3. Run the generator for a few minutes so the treated
4. Store the battery in a cool, dry place.
fuel cycles through the fuel system and carburetor.
4. Turn the fuel valve to the “Off” position.
5. Let the generator run until fuel starvation has DANGER
stopped the engine. This usually takes a few minutes.
6. The generator needs to cool acompletely before Generator exhaust contains odorless and colorless
cleaning and storage. carbon monoxide gas.
7. Clean the generator according to the maintenance
section. To avoid accidental or unintended ignition of your
8. Change the oil. electric start generator during periods of storage,
9. Remove the spark plug and pour about 1⁄2 ounce the following precautions should be followed:
(14.8 mL) of oil into the cylinder. Crank the engine –– When storing the generator for short periods of
slowly to distribute the oil and lubricate the cylinder. time make sure that the Ignition Switch and the
10. Reattach the spark plug. FuelValve are set in the OFF position.
11. Store the unit in a clean, dry place out of direct –– When storing the generator for extended periods
sunlight. of time make sure that the Ignition Switch and
the Fuel Valve are set in the OFF position and
Battery the battery leads have been disconnected from
This product is equipped with an automatic battery the battery.
charging circuit. The battery will receive charging
voltage when the engine is running. The battery will
maintain a proper charge if the unit is used on a regular
basis (about once every two weeks). If it is used less
frequently, the battery should be connected to a trickle
18
ENGLISH 100111
Specifications
Engine Specifications Spark Plugs
–– Model. . . . . . . . . . . . . . . . . . . . . . YF2V78FD-SAI OEM spark plug: NHSP F6RTC
–– Displacement. . . . . . . . . . . . . . . . . . . . . . . 717cc Replacement spark plug: NGK BPR6ES or equivalent
–– Type. . . . . Milwaukee Series OHV Commercial V-Twin Make certain the spark plug gap is 0.7 - 0.8 mm or
–– Start Type . . . . . . . . . . . . . . . . . . . . Electric Start (0.028 - 0.031 in.).
Oil
Use 10W-30 automotive oil.
Oil capacity is up to 1.4 qt. (1.3 L).
DO NOT OVERFILL.
Please reference the following chart for recommended
oil types for use in the generator.
19
250V 50A 250V 30A B
DOUBLE POLE CIRCUIT BREAKER
DOUBLE POLE
20A
B B B B
B R DUPLEX A DUPLEX B
Wiring Diagram
100111 ENGLISH
INTELLIGAUGE
G/Y
W R W
MW1 W W
W W R
R CIRCUIT
R BREAKER
R G/Y 30A G/Y
50A CIRCUIT BREAKER
R R R R 30A 20A
R
R R
G/Y G/Y
FW G/Y G/Y G/Y
EARTH
Y G TRANSITION Y Y TERMINAL
W W R
L L B
L L AVR W B
B
EXW R G/Y
+ G/Y
R R
G (-) G/Y G/Y
Br (+)
B/W
B CHARGER BR B/W 9 12 ST
G B/W
G G + − 2 5 8 11 ON
FUSE 5A 1 4 7 OFF
DCW
W
G G
GENERATOR BLOCK W
ENGINE BLOCK
FUSE B
10A
R
B R
B/R
Y
COMBINATION SWITCH B/W
W
1 2 4 5 7 8 9 11 12
OFF SPARK PLUG IGNITION COIL R
Y
ON R
ST
B BLACK Br BROWN M
Y YELLOW B/W BLACK WHITE
L BLUE W/G WHITE GREEN
G GREEN G/Y GREEN YELLOW B
R RED W/L WHITE BLUE
W WHITE B/R BLACK RED B
FUEL CUT OIL PRESSURE
SPARK PLUG IGNITION COIL
BATTERY STARTER SOLENOID SWITCH
Specifications
20
21
Parts Diagram
5 6 10
31 51 4 11
50 49 6 12
52 48 1 5
4 13
Specifications
53 47 46 2 14
31 45 44 3
51 43
17
54 7 15
18 8
42 16
55 9 11
41 19
56
57 60 40 20 21
59 39 22
58 38 23 25 26
61 24 27
37 28
62 63 29
36
35
64 95 34
33
65 96 29
66 96 32
66 31
67 95 30
94 29
68
69 124
70 93 41 125
126
72 92 127
120
89 89 121
71 72 73 74 88 88 122
75 97 119 118 117 116 123
76 87 86 87 98
78 115 128
77 80 86 29 99
79 81 85 90 91 114
82 101 100
83 103 102 113
84 105 104 107 106 108 91 109 110 111 112
ENGLISH 100111
100111 ENGLISH
Specifications
Parts List
# Part Number Description Qty # Part Number Description Qty
1 100181 Engine 1 55 172.070014.01 Pipe, air cleaner, 1220 mm 1
2 172.190007.00 Crankcase Cover 1 56 172.070014.00 Pipe, reversal valve, 970 mm 1
3 1.5789.1022 Flange bolt M10 x 22 4 57 172.070031.00 Jacket, pipe 2
4 717.100001.00 Gasket, exhaust 2 58 2.06.027 Clamp Ø12 x B8 2
5 1.93.08 Lock washer Ø8 4 59 172.070011.01 Fuel pipe, 65 mm 1
6 2.02.033 Nut M8 4 60 172.070400.00 Fuel valve 1
7 1.16674.0616 Flange bolt M6 x 16 2 61 2.06.004 Clamp Ø8 x Ø1 1
Gasket, Secondary Air Intake 62 2.06.005 Clamp Ø9 x Ø1 1
8 24.100300.03 1
Valve 63 172.070700.00 Carbon canister 1200 cc 1
9 717.100300.00 Secondary Air Intake Valve 1 64 61138.0.2 Frame 1
10 717.101000.03 Muffler assembly 1 65 1.6182.10 Lock nut M10 2
11 1.16674.0820 Flange bolt M8 x 20 2 66 1.6177.1.10 Lock nut M10, flange 4
12 717.101300.01 Spark arrester assembly 1 67 172.201600.00.2 Supporter, engine 1
13 717.101503.01 Plate, spark arrester 1 68 172.201200.00 Motor mount 1 2
14 1.9074.17.0612 Bolt/washer assembly M6 x 12 2 69 172.201701.00.48 12 in. PU wheel, yellow 2
15 717.100005.01 Rubber pillow 1, muffler 1 Pin roll, wheel,
70 172.201501.00 2
16 717.100005.02 Rubber pillow 2, muffler 1 Ø16 x Ø12 x 116
Rotor assembly, Cu, 71 1.848.12 Washer Ø12 2
17 172.191100.00 1
Ø230 x 160 mm 72 1.6177.1.08 Lock Nut M8, Flange 9
18 172.191002.00 Cover, stator 1 73 2.16.001 Pin Ø2 x 33, “R” Shape 2
Stator assembly, Cu, 74 2.05.001 Clamp, Ø8 x 6.5 2
19 172.191200.00 1
Ø230 x 160 mm
75 163.200013.01 Red jacket 1, Wire 2
20 172.190002.00 End housing 1
76 5.1900.082 Red wire 400 mm, battery 1
21 161.190300.00 Carbon brush assembly 1
77 163.200013.00 Black jacket 2, wire 1
22 122.190004.01 Pinch, carbon brush 1
78 1.5789.0608 Flange bolt M6 x 8 1
23 1.93.05 Lock washer Ø5 1
79 5.1900.083 Black wire 350 mm, battery 1
24 1.5783.0520 Bolt M5 x 20 1
80 1.62.06 Butterfly nut M6 2
25 2.13.030 Bush, Ø6 x Ø14 x 15 2
81 172.200902.00.2 Pressure plate, battery 1
26 1.16674.0535 Flange Bolt M5 x 35 2
82 152.200014.00 Curved screws M6 x 150 2
27 172.190400.00 Terminal block 1
83 1.6177.1.05 Lock Nut M5, Flange 2
28 172.190003.00.48 End cover, generator, yellow 1
84 1.16674.0512.2 Flange Bolt M5 x 12 2
29 1.5789.0612 Flange bolt M6 x 12 8
85 9.1000.330 Battery 12V33AH 1
30 172.190202.00 Holder 1, AVR 1
86 1.5789.0825 Flange bolt M8 x 25 2
31 1.5789.0615 Flange bolt M6 x 15 6
87 152.201400.00 Rubber, support 2
32 172.190200.00 AVR 1
88 172.200002.00.2 Support leg 2
33 172.190202.01 Holder 2, AVR 1
89 1.5789.0816 Flange bolt M8 x 16 4
34 1.16674.0516 Flange bolt M5 x 16 1
90 5.1900.084 Grounding line 200 mm 1
35 1.7244.08 Lock washer Ø8 4
91 1.862.06 Lock washer Ø6, toothed 2
36 1.97.1.08 Washer Ø8 4
92 152.200702.02 Cover, handle 1
37 2.08.112 Flange bolt M8 x 210 4
93 172.200701.00.2 Handle, U shape 1
38 1.7244.10 Lock washer Ø10 1
94 171.201200.01 Motor mount 2 2
39 1.96.10 Flat washer Ø10 1
95 1.894.1.10 Circlip ø10 2
40 2.08.129 Flange bolt M10 x 310 1
96 172.200703.00 Long pin, handle 2
41 1.5789.0615.1 Flange bolt m6 x 15, black 8
97 172.219.1.2 Control panel 1
42 172.200800.00.2 Decorative plate, black 1
Screw/washer assembly
43 122.070015.01 Mount vibration, fuel tank 4 98 1.9074.4.0514.1 6
M5 x 14, black
44 2.03.004 Washer, Ø24 x Ø6.5 X 1.5 4 99 5.1000.007 Ignition switch, red 1
45 1.93.06 Lock washer Ø6 4 100 5.1120.039 Receptacle 14-50R 1
46 1.5789.0620.2 Flange bolt M6 x 20 4 101 5.1870.007 Receptacle cover, 14-50R 1
47 172.071000.00.48 Fuel tank, yellow 1 102 5.1120.026 Receptacle L14-30R, CSA 1
48 122.070300.03 Fuel filter assembly 1 103 5.1870.003 Receptacle cover, L14-30R 1
49 122.070100.07 Cap, fuel tank 1 104 5.1120.023 Receptacle L5-30R, CSA 1
50 24.070800.00 Reversal valve 1 105 5.1870.006 Receptacle cover, L5-30R 1
51 172.200509.00 Pin, top cover 2 Receptacle 5-20R, duplex,
106 5.1120.050 2
52 172.200505.00.48 Protector cover 1 GFCI
53 172.200501.00.48 Top cover 1 107 5.1870.005 Receptacle cover, 5-20R, GFCI 2
54 2.06.006 Clamp Ø7 x Ø1 2 108 1.6177.1.04 Lock nut M4, flange 10
22
ENGLISH 100111
Specifications
Parts List Cont’d.
# Part Number Description Qty
109 1.5783.0622.3 Bolt M6 x 22, green 1
110 1.6175.06.3 Nut M6, green 2
111 1.97.1.06.3 Washer Ø6, green 2
112 1.93.06.3 Lock washer Ø6, green 2
Screw/washer assembly
113 1.9074.4.0306.1 8
M3 x 6, black
30Amp circuit breaker,
114 5.1240.930 1
double pole, CSA
50Amp circuit breaker,
115 5.1241.950 1
double pole, CSA
20Amp circuit breaker,
116 5.1210.920 2
push button
30Amp circuit breaker,
117 5.1210.930 1
push button
118 5.1440.005 Intelligauge, four in one 1
119 717.130200.00 Pull choke assembly 1
120 5.1820.001 Charger 1
121 1.818.0514.2 Screw M5 x 14 2
122 5.1810.008 Over voltage protector, CSA 1
123 100111.21.10 Wire assembly 1
124 172.210002.00.2 Control box, black 1
125 172.210003.01 Wire jacket, control box 1
126 5.1320.024 Sheath, wire, Ø23.5 x 300mm 1
127 172.210003.02 Plug, end cover 1
128 100111.21 Control panel assembly 1
23
141 42
142 14
2 140
143 122
1
144 150
123
145 151
124
147 153 2 1
125
148
120
149
119
126 155 14 16 156 138
Engine Parts Diagram
118
127
117
138
108 116
137
115
136 128
114
135
129
134 113
130
112
136
131
111
158
157 110
132
109
139
115 154 99
113 133
114
107 98
129 112
106 97
111
105 96
87
107 104
103 95 81
58 102 82
91 83
46 5 94 90
47 4 89 84
3 85
132 2 32 86
48 1
101 80 88
83 79
100 93 78
77
49 76
50 75
51
15
1 52
2 53
15 64
3 54 65
66
55 67
56
57
14 58 68
15 59 69
60
61 70
62 71
17 18 63
11
12 72
13
4 44 73
45 43
27 74
42
41
22
23 40
27 39
7 24 38
8 25 28
5 19
6 9
10 27
15
29
20
26
21 30
92
31 33
34
35
36
37
Specifications
24
ENGLISH 100111
Specifications
25
100111 ENGLISH
Specifications
26
ENGLISH 100111
Troubleshooting
27
WARRANTY* Other Exclusions
CHAMPION POWER EQUIPMENT This warranty excludes:
3 YEAR LIMITED WARRANTY –– Cosmetic defects such as paint, decals, etc.
–– Wear items such as filter elements, o-rings, etc.
Warranty Qualifications –– Accessory parts such as starting batteries, and storage
To register your product for warranty and FREE lifetime call center covers.
technical support please visit:
https://www.championpowerequipment.com/register –– Failures due to acts of God and other force majeure events
beyond the manufacturer’s control.
To complete registration you will need to include a copy of the
purchase receipt as proof of original purchase. Proof of purchase –– Problems caused by parts that are not original Champion
is required for warranty service. Please register within ten (10) Power Equipment parts.
days from date of purchase. When applicable, this warranty does not apply to products used
for prime power in place of a utility.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the mechanical and Limits of Implied Warranty and
electrical components will be free of defects in material and Consequential Damage
workmanship for a period of three years (parts and labor) from
Champion Power Equipment disclaims any obligation to cover
the original date of purchase and 270 days (parts and labor) for
any loss of time, use of this product, freight, or any incidental
commercial and industrial use. Transportation charges on product
or consequential claim by anyone from using this product.
submitted for repair or replacement under this warranty are the
THIS WARRANTY AND THE ATTACHED U.S. EPA and/or CARB
sole responsibility of the purchaser. This warranty only applies to
EMISSION CONTROL SYSTEM WARRANTIES (WHEN APPLICABLE)
the original purchaser and is not transferable.
ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS
Do Not Return The Unit To The Place Of FOR A PARTICULAR PURPOSE.
Purchase A unit provided as an exchange will be subject to the warranty
Contact CPE’s Technical Service and CPE will troubleshoot any of the original unit. The length of the warranty governing the
issue via phone or e-mail. If the problem is not corrected by exchanged unit will remain calculated by reference to the purchase
this method, CPE will, at its option, authorize evaluation, repair date of the original unit.
or replacement of the defective part or component at a CPE This warranty gives you certain legal rights which may change
Service Center. CPE will provide you with a case number for from state to state or province to province. Your state or province
warranty service. Please keep it for future reference. Repairs or may also have other rights you may be entitled to that are not
replacements without prior authorization, or at an unauthorized listed within this warranty.
repair facility, will not be covered by this warranty.
Contact Information
Warranty Exclusions Address
This warranty does not cover the following repairs and equipment:
Champion Power Equipment, Inc.
Normal Wear 12039 Smith Ave.
Products with mechanical and electrical components need Santa Fe Springs, CA 90670 USA
periodic parts and service to perform well. This warranty does not www.championpowerequipment.com
cover repair when normal use has exhausted the life of a part or Customer Service
the equipment as a whole.
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)
Installation, Use and Maintenance Toll Free: 1-877-338-0999
This warranty will not apply to parts and/or labor if the product is info@championpowerequipment.com
deemed to have been misused, neglected, involved in an accident, Fax no.: 1-562-236-9429
abused, loaded beyond the product’s limits, modified, installed Technical Service
improperly or connected incorrectly to any electrical component.
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)
Normal maintenance is not covered by this warranty and is not
Toll Free: 1-877-338-0999
required to be performed at a facility or by a person authorized by
tech@championpowerequipment.com
CPE.
24/7 Tech Support: 1-562-204-1188
*Except as otherwise stipulated in any of the following enclosed Emission Control System Warranties (when applicable) for the Emission Control System: U.S. Environment Protection Agency
(EPA) and/or California Air Resources Board (CARB). Whichever warranty applies for the longer period, either this 3 year limited warranty or the applicable Emission Control System Warranty,
shall supersede the other.
CHAMPION POWER EQUIPMENT, INC. (CPE),
THE UNITED STATES ENVIRONMENT PROTECTION AGENCY (U.S. EPA)
AND THE CALIFORNIA AIR RESOURCES BOARD (CARB) EMISSION CONTROL SYSTEM WARRANTY
Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board
(CARB) Exhaust and Evaporative emissions regulations.