Philips Master Spectrum

Yellow LEDtube T8
Master LEDtube is a reliable value-for-money LED lamp out of
Philips lighting portfolio, incorporates frontier LED chips and other
advanced technologies. The product helps customers achieve energy
saving and significant maintenance cost reduction by comparing to
fluorescent lamps. It also helps generate the required lighting effect,
and to increase efficiency and build up green and environment
friendly image for our customers.
Product Features

Highly Reliable Highly Safe


• Reliable operation between -20 C to 45 C • Protection circuit inside ensuring people's
O O

ambient temperature safety in case of mis-use, complying with IEC


• Rated average life of 50,000 hours (tested to safety requirements
B50 L70 requirement) • Pass 4KV high-pot test, insulation & safety
• 200,000 switching cycles guaranteed
• Pass 1KV surge test (vs. IEC standard 500V),
Highly Comfortable avoiding the damage caused by input voltage
• CRI 50 fluctuation and lightning strike
• Advanced optical design ensures a uniform light
output and superior optical efficiency Highly Fit
• 100% comply with IEC requirement on T8
Highly Energy Efficient dimension, fitting into fluorescent luminaire
• Energy savings of more than 60%* perfectly

* Based on comparison between 14W Master LEDtube Yellow Highly Environmental Friendly
and Philips TLD Yellow 36W(40-44W system power when • No mercury
working with Electro Magnetic Ballasts) • No breakage and pollution risk

Application

Industry

Spectral Power Distribution

Light may be precisely characterized by giving the power of the light at the required wavelength. The
resulting spectral power distribution (SPD) shows that the Master LEDtube standard contains the
yellow light only.

3.5ft 1400lm 2000K 4ft 1400lm 2000K


100% 100%
90% 90%
Intensity (mW/nm) in %

Intensity (mW/nm) in %

80% 80%
70% 70%
60% 60%
50% 50%
40% 40%
30% 30%
20% 20%
10% 10%
0% 0%
200 250 300 350 400 450 500 550 600 650 700 750 800 200 250 300 350 400 450 500 550 600 650 700 750 800

Wavelength (nm) Wavelength (nm)

3
5ft 2200lm 2000K
100%
90%
Intensity (mW/nm) in %

80%
70%
60%
50%
40%
30%
20%
10%
0%
200 250 300 350 400 450 500 550 600 650 700 750 800

Wavelength (nm)

Photometric Diagrams

The Photometric diagram depicting the top down mounted lighting fixtures in a specific area and a
numerical grid of the maintained lighting levels that the fixture will produce in that specific area.
Pictures below show the photometric diagrams of a typical Philips Master LEDtube's application.

MAS LEDtube Spectrum 1200mm 1400lm 14W 1 x 1400 lm

MAS LEDtube Spectrum 1500mm 2200lm 20W 1 x 2200 lm

4
MAS LEDtube Spectrum 1200mm 1400lm 14W 1 x 1400 lm

MAS LEDtube Spectrum 1500mm 2200lm 20W 1 x 2200 lm

Lifetime and Lumen Maintenance

100%
Philips Master LEDtube has a lifetime of 50,000
Lumen Maintenance

95%
hours, defined as the number of hours when 50%
90% of a large group of identical lamps below 70% of
85% its initial lumens.
80%

75%

70%
0 10000 20000 30000 40000 50000

Hours

Temperature

Master LEDtube's excellent thermal design ensures low temperature during operating, which brings
reliable and stable product performance throughout life time.

Operating temperature T operating min -20°C max +45°C


Storage temperature T storage min -40°C max +65°C
Maximum case temperature of tube at Tamb.=25°C T case +55°C

5
100%
99%
98%
97%
Lumen (% )

96%
95%
94%
93%
92%
91%
90%
55 60 65 70 75
Tc ( oC)

Dimension: mm

B
25

B 43 o
5’

Tc Position Tc Position
Diffusive Side
24

White Side

SECTION B-B
25

Approbation & Certificates

Philips Master LEDtube is designed by strictly following applicable legislation and international standard.
The product complies with CE, KEMA, TISI, RoHS and REACH.

Technical specification
10NC Product Description Wattage Equivalent Voltage Cap Length Beam Lifetime Lumen Color CRI
Fluorescent angle output Temp
Wattage (Typical)
(W) (W) (V) (mm) ( O) (hrs) (lm) (K) (Typical*)
MAS LEDtube Spectrum
9290018265 1047mm 1400lm 14 32 220-240 G13 1050 160 50000 1400 2200 50

MAS LEDtube Spectrum


9290018264 1200mm 1400lm 14 36 220-240 G13 1200 160 50000 1400 2200 50

MAS LEDtube Spectrum


9290018263 1500mm 2200lm 20 58 220-240 G13 1500 160 50000 2200 2200 50

* Minimum CRI is 80

6
A3
A2
A1

D1
Dimensions (mm)
Product A1 A2 A3 D1

1050mm 1047 1054 1061 27.9

1200mm 1199 1206.5 1213.6 27.9

1500mm 1500 1507.1 1514.2 27.8

Installation Guide

OFF

ON

1 2 2

Mains Off Remove all existing FLUORESCENT TUBES from luminaire

For 3 lamps use diagram A & B For 4 lamps use diagram B & B

Diagram A Diagram B

L
LEDtube
L
N
LEDtube Warning sticker
N

LEDtube
3 3 4

Bypass existing BALLAST and rewire according The supplied warning


to the following diagrams. sticker must be placed
Please check the L/N markings on the lamp on the luminaire and
end and insert the lamp with AC mains must be visible during
supplied to the corresponding end. lamp replacement
L N
To install the lamp in the wrong direction will
lead to malfunction.

OFF

ON

Turn on mains

7
OEM Guideline

Lifetime vs. Failure Rate @ Ta 25 OC Lifetime and Lumen Maintenance

100% 100%
90%

Lumen Maintenance
Total Failure Rate

95%
80%
70% 90%
60%
50% 85%
40%
30% 80%

20%
75%
10%
0 70%
0 10000 20000 30000 40000 50000 60000 0 10000 20000 30000 40000 50000
Hours Hours

Failure Rate vs. Lifetime vs. Tcase


Lifetime vs. Tcase

80% TC=70 oC 60000 F10L70


Total Failure Rate

Total Failure Rate


70% o
TC=60 C 50000 F50L70
60%
TC=50oC 40000
50%
40% 30000
30%
20000
20%
10000
10%
0 0
0 10000 20000 30000 40000 50000 60000 40 50 60 70
Hours o
TC ( C)

© 2018 Philips Lighting


All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the
copyright owner. The information presented in this document does not form part of any quotation or
contract, is believed to be accurate and reliable and may be changed without notice. No liability will be
accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply
any license under patent or other industrial or intellectual property rights.

01/2018
www.philips.com