PAMAS S40 AVTUR

Portable Particle Counting System


for Aviation Turbine Fuel
The PAMAS S40 AVTUR is a special Applications:
version of the very successful PAMAS ƒƒ Online measurements at pressureless systems or at live systems up to 6 bar
S40 automatic particle counting
ƒƒ Offline measurement using sample bottles (laboratory mode)
system that helps the aviation fuel
industry to gather very accurate ƒƒ Long term analysis
and reliable contamination analysis ƒƒ Bypass filtration monitoring
results.
ƒƒ Filter verification
The PAMAS S40 AVTUR has its own
IP method (IP577), that was drafted, Key features:
validated and published by the Ener- ƒƒ 8 channel high resolution digital system for analysis
gy Institute in London. ƒƒ Fully compliant with the standard method IP 577
of the Energy Institute London
This guarantees highest quality of
the method and best compatibility ƒƒ Fully compliant with the standard DEF STAN 91-91
with other methods for contamina- of the UK Ministry of Defence
tion control. The method IP 577 has ƒƒ According to ISO 4406 4 µm(c),
been included in revision 7 of the 6 µm(c), 14 µm(c) based on ISO 11171
DEF STAN 91-91 published by the UK
Ministry of Defence. ƒƒ from pressureless to pressurised sampling up to 6 bar
ƒƒ User-friendly operation using touch screen with graphic display

REV 09/2018
I n t h e w o r l d o f pa r t I c l e s pa m a s c o u n t s
PAMAS S40 AVTUR
Easy documentation of contamination,
cleaning process, and filtration performance
ƒƒ The volumetric cell design of The PAMAS S40 AVTUR is Single particle counting Technical data
PAMAS sensors guarantees a portable system designed to system using volumetric Sampling system:
highest accuracy, resolution count and size particles in fuels, sensor cells ƒƒ Wear resistant ceramic piston pump
and best statistical information oil and hydraulic fluids. A backlit A highly sophisticated sensor cell with controlled constant flow.
touch screen for menu guided and optics guarantees best resolu- Pressure range:
ƒƒ Measuring results reported in
user access, and an additional tion and accuracy even under high ƒƒ From pressureless
compliance with IP 577, DEF
STAN 91-91, ISO 4406, NAS membrane keypad give easy pressure conditions. up to 6 bar (85 psi)

1638, SAE AS 4059, GJB 420, operation. An integrated printer PAMAS Volumetric Sensor:
Particle counting can be achieved
GOST 17216 and NAVAIR 01- provides instant hard copies PAMAS HCB-LD-50/50
using many methods, but only
1A-17. of measurement results. Calibration ranges:
the use of volumetric cells, like ƒƒ 4 - 70 µm(c) according to ISO 11171
Data files are compatible with (standard calibration)
those used in PAMAS sensors, can
ƒƒ Real portability with most spreadsheet software. ƒƒ 2 - 100 µm according to ISO 4402
lab system accuracy guarantee that all particles passing (optional calibration)

Eingetragene Warenzeichen und Markennamen gehören deren jeweiligen Eigentümern. Alle Beschreibungen sind lediglich informativ und unterliegen Änderungen im Rahmen der ständigen Weiterentwicklung.
through the sensor are counted.
Highly versatile due to a powerful Max. particle concentration:
ƒƒ Users can configure the 32-bit microprocessor allowing This results in better statistical 24,000 p/ml at a nominal flow rate
system profile according multiple automated sampling analysis and prevents the loss of of 25 ml/min and a coincidence
to their needs rate of 7.8%.
and data storage. User-friendly information compared to in-situ
ƒƒ Pressurised sensor avoids download software for transfer cells that detect only a small Counter:
formation of bubbles of stored measurement data to portion of the whole sample ƒƒ 8-channel particle counter
ƒƒ 32-bit high performance CPU
a PC as a basic feature. flow, especially as the samples with sophisticated programmable
ƒƒ Display and printout provide are getting cleaner. ƒƒ digital domain signal conditioning
triple ISO codes, NAS- and SAE Standard languages are English, and 4096 internal channels
ƒƒ Data printout:
cleanliness classes, measure- German, French, Finnish, Dutch, Calibration 32 column thermo printer
ment volumes and particle Spanish, Hungarian, Russian, The Automatic Particle Counter ƒƒ Data transfer:
numbers Chinese and Portuguese. is calibrated according to Inter- 8 bit ASCII code through
USB port (57600 baud)
national Calibration Standards. ƒƒ Power supply:
ƒƒ Highest repeatability The calibration is traceable to 90-240 V AC / 50-60 Hz
and accuracy
Standard Reference Material® or 12-30 V DC
or via integrated battery for
ƒƒ Password protected user levels of the NIST (National Institute up to 3 hours operation
of Standards and Technology). ƒƒ Weight:
More than one calibration can be approximately 8 kg
ƒƒ Data storage of more ƒƒ Size:
than 4000 measurements preconfigured in a single system. 310 mm x 145 mm x 360 mm

ƒƒ User-friendly Standards Options:


download software ƒƒ rugged case PAMAS GO
Display shows particle numbers, for harsh environments
For batch sampling, the PAMAS
cleanliness classes and size.
ƒƒ Operates on alternating S40 AVTUR is equipped with a
Printout according to many
current (90 - 240 V / 50 - 60 sampling probe.
international standards
Hz AC) or on direct current
(e.g. IP 577, DEF STAN 91-91,
(12 - 30 V DC) or with internal
battery (for up to three hours ISO 4406, NAS 1638, SAE AS
operation) 4059, GJB 420, GOST 17216,
NAVAIR 01-1A-17).
ƒƒ equipped with a sampling
probe for batch sampling
Rugged case PAMAS GO
for harsh environments

PAMAS HEAD OFFICE Dieselstraße 10, D-71277 Rutesheim, Phone: +49 7152 99 63 0, Fax: +49 7152 99 63-32, Email: info@pamas.de
PAMAS USA 1408 South Denver Avenue, Tulsa, OK 74119 USA, Phone: +1 918 743 6762, Fax: +1 918 743 6917, Email: clay.bielo@pamas.de
PAMAS Benelux Mechelen Campus, Schaliënhoevedreef 20T, B-2800 Mechelen, Phone: +32 15 28 20 10, Mobile: +32 477 42 48 62, Email: paul.pollmann@pamas.de
PAMAS France Route du Tailleur 210/136, F-40170 Saint-Julien-en-Born, Mobile +33 6 25 33 20 41, Email: eric.colon@pamas.fr
PAMAS LATIN AMERICA Curitiba-Paraná, Brazil, Phone/Fax: +55 41 3022 5445, Mobile: +55 41 999 72 21 73, Email: marcelo.aiub@pamas.de
PAMAS INDIA No. 203, I floor, Oxford House, #15 Rustam Bagh Main Road, Bangalore 560017, India, Phone: +91 80 41 15 00 39, Email: info@pamas.in
PAMAS HISPANIA Calle Zubilleta No. 13 1°B, ES-48991 Algorta, Mobile: +34 67 75 39 699, Email: julian.malaina@pamas.de
PAMAS UK Sci-Tech Daresbury, Keckwick Lane, Daresbury, Cheshire WA4 4FS, Mobile: +44 79 17 71 33 66, Email: graeme.oakes@pamas.de

Besuchen Sie uns im Internet: www.pamas.de


®

You might also like