TAC Xenta 300 TM

Programmable
Controllers

TAC Xenta 300 is a range of LonMark®-certified programmable


controllers intended for control of small and medium-sized heating,
ventilation and air-conditioning systems.
02

TAC Xenta 300 Programmable Controllers


Features

TAC Xenta 300 is designed for use


in open systems and integration via
LonWorks® – an industrial standard for
network communications which enables
a range of different systems within a
property, such as HVAC, lighting and
access control, to be integrated on the
same network.

TAC Xenta 300 provides an open, future-proof


system architecture. At the same time, it provides
access to standardized network technology
supporting a flexible control system, to which
Product AT A GLANCE components from other manufacturers can be
connected.
• Optimized for maximum flexibility in HVAC
Designed for Effective Control of Heating
control with on board inputs and outputs
and Ventilation
• Fully programmable using the intuitive The TAC Xenta 300 has full HVAC functionality,
TAC Menta programming tool including control loops, control curves, time control,
• Intelligent start time calculation minimizing alarm handling, etc.
energy usage
The controller consists of an optimum combination
• Designed for use in open systems and
of digital and analogue inputs and outputs which
integration via LonWorks
are intended specifically for heating and ventilation
applications, such as for control of fans and
pumps. When required, the TAC Xenta 300 can be
expanded with further I/O modules.

Simplicity of Installation
The TAC Xenta 300 is a freely programmable
controller that can be fitted in a standard enclosure
or a control panel.

Installation is extremely simple. The controller is


designed for installation adjacent to the equipment
that it controls, which greatly simplifies wiring.

The unique TAC MentaTM graphic programming tool


quickly adapts the controller for different types of
control and/or supervisory applications.

Engineering is further simplified by the fact that TAC


Menta contains a large number of pre-programmed
function blocks, together with a comprehensive
library of functions.

Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9674 www.schneider-electric.com/buildings

SDS-XENTA300-A4.BU.N.EN.1.2006.0.00.CC
03

TAC Xenta 300 Programmable Controllers


Features (continued)

Developed for Network Communication TAC Xenta OP


The TAC Xenta can be used either independently or
as a communicating controller in a larger system.
Several controllers can be easily connected to form
a network and exchange data. In addition, the TAC
Xenta 300 can be connected to TAC VistaTM – a
supervision system running under Windows® for
controlling and analyzing all aspects of performance,
either in individual buildings or a whole area

LonMark-Certified – For Open Communication


The TAC Xenta 300 is LonMark-certified. It
commu-nicates via a TP/FT-10 network, enabling
it to be integrated with other systems such as
lighting, sunblinds and access control for overall
optimization of environmental conditions and
operating costs.
Rapid Control via TAC Xenta OP
Standard Network Variable Types (SNVT) enable TAC Xenta OP is a portable operator’s panel intended
various subsystems to exchange information easily for direct connection to the controller or the network.
with each other. Regardless of where it is connected, it communicates
with other units in the network.
Advanced Datalog and Time Control
TAC Xenta 300 has a local datalog which can be A menu system on the unit provides the operator with
retrieved and stored in TAC Vista either on-site or access to all essential parameters and enables him/her to
through a dial-up connection. The benefit of local check system status, change settings, read off measured
storage is reduced network communication and the values, adjust set values etc. All values are displayed with
possibility to use many parallel logchannels. explanatory text and in a logical sequence.

Start and stop of the datalog can be event or time The system manager can also restrict the use of
controlled. The “smart log” maximizes storage TAC Xenta OP by setting up authorization codes so
capacity by only logging values that actually have that changes to the program can be made only by
changed. authorized persons.
© 2006-2009 Schneider Electric. All rights reserved.

All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change
without notice.
On October 1st, 2009, TAC became the Buildings Business of its parent company Schneider Electric. This document reflects the visual identity of Schneider Electric,
however there remains references to TAC as a corporate brand in the body copy. As each document is updated, the body copy will be changed to reflect appropriate
corporate brand changes.
Schneider Electric One High Street, North Andover, MA 01845 USA Telephone: +1 978 975 9600 Fax: +1 978 975 9674 www.schneider-electric.com/buildings

SDS-XENTA300-A4.BU.N.EN.1.2006.0.00.CC January 2006 pdw

You might also like