Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Projection By:

Client name:
Project Id:
Project:
Version: 6.015.07 release date: May 31, 2021 Reference:
Name: RO Chemical Pretreatment Location: Peru / *Lima

Unit Unit
Source: Surface Water (MMF Pretreatment) Feed Pressure: bar 11.462
Feed Temperature: °C 25.000 Total Pressure: bar 3.985
Raw Water Flow/Train: m3/hr 60.006 Brine Pressure: bar 7.477
Permeate Flow/Train: m3/hr 40.000 Permeate Pressure: bar 0.000
Average Flux Rate: gfd 17.610 System Recovery: % 66.660
Recycling Flow: gal/min 0.000 Internal Recovery: % 66.660
Salt Passage Increase: % 0.000 Element Age: Years 0
Specific Power: kWh/kgal 2.408

Cations Balanced Feed (mg/L) pH Adjusted Feed (mg/L) Reject (mg/L) Permeate (mg/L)
Ca2+ 191.00 191.00 572.28 0.30
Mg2+ 14.97 14.97 44.87 0.02
Ba2+ 0.00 0.00 0.00 0.00
Sr2+ 0.00 0.00 0.00 0.00
Na+ 65.16 65.16 191.41 2.02
K+ 2.67 2.67 7.84 0.08
Fe2+ 0.00 0.00 0.00 0.00
Fe3+ 0.00 0.00 0.00 0.00
Al3+ 0.00 0.00 0.00 0.00
Mn2+ 0.00 0.00 0.00 0.00
NH3/NH4 - N 0.00 0.00 0.00 0.00

Anions Balanced Feed (mg/L) pH Adjusted Feed (mg/L) Reject (mg/L) Permeate (mg/L)
HCO3-(CaCO3) 218.15 218.15 641.13 3.10
CO32-(CaCO3) 0.85 0.85 10.28 0.00
CO2 45.17 45.17 48.56 44.84
TIC (C) 64.78 64.78 168.36 12.98
Ortho-PO43- 0.00 0.00 0.00 0.00
SO42- 161.70 161.70 484.71 0.15
F- 0.00 0.00 0.00 0.00
Cl- 210.00 210.00 626.39 1.74
Br- 0.00 0.00 0.00 0.00
SiO2 0.00 0.00 0.00 0.00
NO3--N 0.00 0.00 0.00 0.00
NO2--N 0.00 0.00 0.00 0.00
Sulfides (S2-) 0.00 0.00 0.00 0.00
B 0.00 0.00 0.00 0.00
As(III) 0.00 0.00 0.00 0.00
As(V) 0.00 0.00 0.00 0.00
TOC (ppm C) 0.00 0.00 0.00 0.00
H.ORG (mEq/L) 0.00 0.00 0.00 0.00
TDS: 907.600 907.600 2702.470 8.030
Cond (µs/cm): 1250.000 1250.000 3496.078 11.403
pH: 6.900 6.900 7.280 5.130
Flow: m3/hr 0.000 0.000 40.000

Summary Product: Dosage:


pH adjusted using: H2SO4 0.000 mg/L

5 American Water Chemicals Inc does not assume any obligation or liability for results obtained or damages incurred
1 /
from the application of this information.
Projection By:
Client name:
Project Id:
Project:
Version: 6.015.07 release date: May 31, 2021 Reference:
Selected product: Pureflux GW 1.556 mg/L

5 American Water Chemicals Inc does not assume any obligation or liability for results obtained or damages incurred
2 /
from the application of this information.
Projection By:
Client name:
Project Id:
Project:
Version: 6.015.07 release date: May 31, 2021 Reference:

Unit Stage 1 Stage 2


Total Elements: 24 12
Total Vessels: 4 2
Elements / Vessels: 6 6
Flow Factor: 1 1
Feed Pressure: bar 11.46 9.65
Permeate Throttle/ bar 0.15 0.00
Backpressure:
Interstage Boost Pressure: bar 0.00 0.00
Piping Losses: bar 0.00 0.00
Concentrate Pressure: bar 9.65 7.48
Feed Flow: m3/hr 15.00 15.52
Concentrate Flow: m3/hr 7.76 10.00

Hydraulics Details
Permeate Average System Feed Flow Concentrate Osmotic Net Driving
Membrane Model: Flow: Flux: Recovery: / PV: Flow / PV: Pressure: Pressure: Pressure:

m3/hr gfd % m3/hr m3/hr bar bar bar


Stage1 28.96 19.13 48.26 1.18 15.00 7.76 1.81 0.91 9.55
1 CPA5-LD 1.33 21.14 8.89 1.18 15.00 13.67 0.45 0.53 10.56
2 CPA5-LD 1.27 20.21 9.33 1.18 13.67 12.39 0.38 0.58 10.09
3 CPA5-LD 1.22 19.39 9.87 1.18 12.39 11.17 0.32 0.64 9.68
4 CPA5-LD 1.18 18.65 10.54 1.18 11.17 9.99 0.27 0.71 9.32
5 CPA5-LD 1.14 17.99 11.36 1.18 9.99 8.86 0.22 0.80 8.99
6 CPA5-LD 1.10 17.38 12.38 1.18 8.86 7.76 0.18 0.91 8.68
Stage2 11.04 14.58 35.56 1.13 15.52 10.00 2.17 1.36 7.28
1 CPA5-LD 1.07 16.91 6.87 1.14 15.52 14.46 0.48 0.97 8.44
2 CPA5-LD 1.00 15.86 6.92 1.14 14.46 13.46 0.43 1.03 7.92
3 CPA5-LD 0.94 14.92 6.99 1.13 13.46 12.51 0.38 1.10 7.45
4 CPA5-LD 0.89 14.05 7.08 1.13 12.51 11.63 0.33 1.18 7.02
5 CPA5-LD 0.84 13.25 7.19 1.12 11.63 10.79 0.29 1.26 6.62
6 CPA5-LD 0.79 12.51 7.31 1.12 10.79 10.00 0.26 1.36 6.25

5 American Water Chemicals Inc does not assume any obligation or liability for results obtained or damages incurred
3 /
from the application of this information.
Projection By:
Client name:
Project Id:
Project:
Version: 6.015.07 release date: May 31, 2021 Reference:

Summary Scale - Precipitation Potentials (mg/L)


CaCO3 Ca3(PO4)2 CaSO4 SrSO4 BaSO4 CaF2 SiO2 FeCO3 FeS MnCO3 FePO4 Fe(OH)3 Al(OH)3 Mg(OH)2
326.305 0 0 0 0 0 0 0 0 0 0 0 0 0

Summary Scale - X Saturation


CaCO3 Ca3(PO4)2 CaSO4 SrSO4 BaSO4 CaF2 SiO2 FeCO3 FeS MnCO3 FePO4 Fe(OH)3 Al(OH)3 Mg(OH)2
17.551 0 0.362 0 0 0 0 0 0 0 0 0 0 0

If no antiscalant is used, the following scales may form:


CaCO3 Saturation is 17.55 X; [Saturation Index is 1.24], Precipitation Potential: 326.31 mg/l

5 American Water Chemicals Inc does not assume any obligation or liability for results obtained or damages incurred
4 /
from the application of this information.
Projection By:
Client name:
Project Id:
Project:
Version: 6.015.07 release date: May 31, 2021 Reference:
Name: RO Chemical Pretreatment Location: Peru / *Lima

Critical Indices

5 American Water Chemicals Inc does not assume any obligation or liability for results obtained or damages incurred
5 /
from the application of this information.
Projection By:
Client name:
Project Id:
Project:
Version: 6.015.07 release date: May 31, 2021 Reference:
Name: RO Chemical Pretreatment Location: Peru / *Lima

Chemical dosing: Pureflux GW H2SO4


Calculated Dosage: 1.556 mg/L 0.000 mg/L
Total Dosage (modified by user): 1.556 mg/L N/A
% Concentration: N/A 93.000%
Density: 1.070 g/cm3 1.835 g/cm3
Dosing Pump: 1.454 ml/min 0.000 ml/min
Hours of Operation/Day: 24 hour(s) 24 hour(s)
Days of Operation/Week: 7 day(s) 7 day(s)
Consumption per:
Day 4.939 lbs 0.000 lbs
Week 34.573 lbs 0.000 lbs
4 Weeks 138.290 lbs 0.000 lbs
Year 1802.712 lbs 0.000 lbs
5 Years 9013.558 lbs 0.000 lbs

Cleaning Chemicals: High pH Cleaner Low pH Cleaner


Chemical: AWC C-227 AWC C-234
Concentration: 2% 2%
Other options may be available. It is recommended that you discuss CIP system design constraints with your AWC representative when
selecting cleaning chemicals.

Insert your additional comments below:


Nombre comercial del antiincrustante AWC A 102

DISCLAIMER: NO WARRANTY, EXPRESSED OR IMPLIED, AND NO WARRANTY OF MERCHANTABILITY OR FITNESS


FOR A PARTICULAR PURPOSE, IS GIVEN. American Water Chemicals Inc does not assume any obligation or liability for results
obtained or damages incurred from the application of this information. Because use conditions and applicable laws may differ from one
location to another and may change with time, customer is responsible for determining whether products are appropriate for customer’s
use. American Water Chemicals assumes no liability, if, as a result of customer's use of the Proton membrane aqueous chemistry
calculator, the customer should be sued for alleged infringement of any patent not owned or controlled by American Water Chemicals Inc.

5 American Water Chemicals Inc does not assume any obligation or liability for results obtained or damages incurred
6 /