Podium A

Basement None
All equipment connected to
Lower Ground Floor SFACP with PB in Access
Room LF-07
Glass Corridor

Pump Rooms/Stairs A. Control Module A. Manual Pull Station

Pump rooms/Parking Areas A. Monitor Modules Supervisory Switches


Parking Areas A. Manual Pull Stations

Pump Rooms A. Monitor Modules

Pump Rooms/Filter Rooms A. Heat Detectors


Storage Rooms A. Smoke Detectors

Fire Exits/Plant Rooms/Fan Rooms A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches

Fan Rooms A. Control Module A. Smoke Detectors

Fire Exits/Plant Rooms/Fan Rooms A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Pre-Action System Interface A. Monitor Modules

Parking/Open Areas A. Manual Pull Stations

Common Areas A. Smoke Detectors


Storage Rooms A. Smoke Detectors
Access Rooms A. Smoke Detectors
Driver's Lounge A. Smoke Detectors
BOH Rooms A. Smoke Detectors

Fire Exits/Plant Rooms A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Pre-Action System Interface A. Monitor Modules

Common Areas A. Smoke Detectors

Storage Rooms A. Smoke Detectors


Access Rooms A. Smoke Detectors
MDF Rooms A. Smoke Detectors
Driver's Lounge A. Smoke Detectors

Data Center A. Smoke Detectors


Fire Exits A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches

Parking Areas A. Manual Pull Stations

Grease Interceptor Room/Cloak A. Smoke Detectors

Fire Exits A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Parking Areas A. Manual Pull Stations
Common Areas A. Smoke Detectors
Storage Rooms A. Smoke Detectors
Access Rooms A. Smoke Detectors
EE Rooms A. Smoke Detectors

Fire Exits A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Parking Areas A. Manual Pull Stations
Telco Rooms A. Smoke Detectors
MDF Rooms A. Smoke Detectors
Access Rooms A. Smoke Detectors
Fan Rooms A. Smoke Detectors
Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

All equipment connected to


Upper Ground Floor SFACP with PB in Access Room
UG-19
Glass Corridor

Fire Exits A. Control Module A. Manual Pull Station

Fire Exits/Common Areas A. Monitor Modules Supervisory Switches


Common Areas A. Manual Pull Stations
High Ceiling Common Area Reflectors Line Beam Detectors

F&B Dining Including 2F A. Smoke Detectors A. Heat Detectors

Fire Exits A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Common Areas/Office Area/Storage
Rooms/Access Rooms/Retail Areas/BOH A. Smoke Detectors
Rooms/
EE Rooms
Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


High Ceiling Common Area Reflectors Line Beam Detectors

Casino A. Heat Detectors

Common Areas/Office Area/Access


A. Smoke Detectors
Rooms

Fire Exits A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Casino A. Heat Detectors
Common Areas/Office Area/Storage
Rooms/Access Rooms/BOH
A. Smoke Detectors
Rooms/Cages/Distribution Rooms
/EE Rooms

Fire Exits A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Casino A. Heat Detectors
Common Areas/Office Area/Storage
Rooms/Access Rooms/Retail Areas/BOH A. Smoke Detectors
Rooms/Cages/EE Rooms
Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

Mimic Panel at Security


Mid-Upper Ground Floor
Control Room
Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

All equipment connected to


Second Floor SFACP with PB in Access Room
2F-35
Fire Exits/Plant Rooms/Common
A. Control Module A. Manual Pull Station
Areas/Exit Doors
Fire Exits A. Monitor Modules Supervisory Switches
AHU A. Control Module

Data Center A. Monitor Modules

Plant Rooms/Kitchens/Garbage
A. Heat Detectors
Stations/Employee Smoke Area
Common Areas/Office Area/Storage
A. Smoke Detectors
Rooms/Access Rooms/BOH Rooms

Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches

Common Areas/Office Area/Storage


A. Smoke Detectors
Rooms/Access Rooms/BOH Rooms

Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Common Areas/Office Area/Storage
Rooms/Access Rooms/BOH Rooms A. Smoke Detectors

Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Kitchen Dining A. Heat Detectors
Common Areas/Office Area/Storage
A. Smoke Detectors
Rooms/Access Rooms

Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches

Pantry/Kitchen A. Heat Detectors


Common Areas/Office Area/Storage A. Smoke Detectors
Rooms/Access Rooms
Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

All equipment connected to


Third Floor SFACP with PB in Access Room
3F-49

Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches

AHU A. Control Module

Common Areas/Office Areas/BOH


Rooms/Storage Rooms A. Smoke Detectors

Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Common Areas/Office Area/BOH
Rooms/Storage Rooms/Access A. Smoke Detectors
Rooms/Studio/Board Rooms

Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

All equipment connected per


4F to 15F floor connected to PB which
goes to Access Room 4F-02

Fire Exits/Plant Rooms/Common


A. Control Module A. Manual Pull Station
Areas/Exit Doors
Fire Exits A. Monitor Modules Supervisory Switches
Closet/Living Room/Dining Area
(Executive Suite/Pres. Suite) A. Smoke Detectors

Kitchen A. Heat Detector

Bed Rooms A. Smoke Detector with


sounder
Closet/Living Room/Dining Area A. Smoke Detectors
(Junior Suite)
A. Smoke Detector with
Bed Rooms
sounder
Closet (Deluxe Suite) A. Smoke Detectors
A. Smoke Detector with
Bed Rooms
sounder

Common Areas/Storage Rooms/Access


A. Smoke Detectors
Rooms/EE Rooms/MEPF Room

Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

All equipment connected per


Roof Deck floor connected to PB which
goes to Access Room 4F-02

SEF/LPF A. Control Modules


Pump Rooms A. Heat Detectors
All equipment connected to
Lower Ground Floor SFACP with PB in Access Room
LF-11
Glass Corridor
Sounder with Strobe Fire Exits/Common Areas A. Control Module
Light
Flow Switches Fire Exits A. Monitor Modules
Common Areas A. Smoke Detectors

Fire Exits/Plant Rooms/Fan Rooms A. Control Module

Fire Exits A. Monitor Modules


Pre-Action System Interface A. Monitor Modules
Sounder with Strobe
Life Safety Equipment A. Control Module
Light
Flow Switches Plant Rooms A. Heat Detectors

Fire Exits/Common Areas A. Control Module

Sounder with Strobe


Light Fire Exits A. Monitor Modules

Flow Switches Fire Exits A. Monitor Modules


Common Areas A. Smoke Detectors

Fire Exits/Plant Rooms A. Control Module

Fire Exits A. Monitor Modules


Plant Rooms A. Heat Detectors
Common Areas A. Smoke Detectors
Storage Rooms A. Smoke Detectors
Warehouse A. Smoke Detectors
Sounder with Strobe
A. Control Module
Light
JUNKET CASINO/BAR
Flow Switches A. Monitor Modules
A. Heat Detectors

Fire Exits/Plant Rooms/Fan Rooms/


Garbage Rooms/Pre-Action System A. Control Module
Interface/Common Areas/Pump Rooms

Fire Exits A. Monitor Modules


Pre-Action System Interface A. Monitor Modules
Fan Rooms/SE/EF A. Control Module
Food Prep/Wine & Bev. Chiller A. Heat Detectors
Common Areas/Storage Rooms/EE &
A. Smoke Detectors
Access Rooms/Office Rooms
Sounder with Strobe
Parking Areas A. Manual Pull Station
Light
Flow Switches Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

Sounder with Strobe


Light
Flow Switches

Sounder with Strobe


Light
Flow Switches

All equipment connected to


Upper Ground Floor SFACP with PB in Access Room
LG-22 (?)
Glass Corridor
Sounder with Strobe
Fire Exits A. Control Module
Light
Flow Switches Fire Exits/Transfer Stair A. Monitor Modules
Cabana A. Heat Detectors
Common Areas A. Smoke Detectors

Fire Exits A. Control Module

Sounder with Strobe


Light Fire Exits A. Monitor Modules

Flow Switches Casino A. Heat Detectors


Common Areas/Office Area/Storage
Rooms/Access Rooms/Retail Areas/BOH
A. Smoke Detectors
Rooms/
EE Rooms
Sounder with Strobe
Fire Exits A. Control Module
Light
Flow Switches Fire Exits/Transfer Stair A. Monitor Modules
Casino/Bar A. Heat Detectors

Common Areas/Office Area/Break Rooms A. Smoke Detectors

Fire Exits/Plant Rooms A. Control Module

Sounder with Strobe Fire Exits/Transfer Stair A. Monitor Modules


Light
Flow Switches High Ceiling Common Area Reflectors
Casino/Kitchen A. Heat Detectors

Common Areas A. Smoke Detectors

Sounder with Strobe


Fire Exits A. Control Module
Light
Flow Switches Fire Exits/Transfer Stair A. Monitor Modules
Casino A. Heat Detectors

Common Areas/Storage Rooms/Access


A. Smoke Detectors
Rooms/Retail Areas/BOH Rooms

Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

All equipment connected to


Second Floor SFACP with PB in Access Room
2F-41
Sounder with Strobe
Fire Exits/Common Areas A. Control Module
Light
Flow Switches Fire Exits A. Monitor Modules
Private Rooms A. Heat Detectors

Common Areas/Office Area/F&B Dining A. Smoke Detectors

Fire Exits/Common Areas A. Control Module


Fire Exits A. Monitor Modules

Sounder with Strobe Private Rooms A. Heat Detectors


Light
Common Areas/Storage Rooms/Access
Flow Switches A. Smoke Detectors
Rooms

Fire Exits/Common Areas A. Control Module

Sounder with Strobe Fire Exits A. Monitor Modules


Light
Flow Switches Employee Dining/Private Rooms A. Heat Detectors
Common Areas/Office Area/Storage
Rooms/Access Rooms A. Smoke Detectors

Sounder with Strobe


Fire Exits/Common Areas A. Control Module
Light
Flow Switches Fire Exits A. Monitor Modules
Cabana/Cooking Areas A. Heat Detectors

Common Areas/Office Area A. Smoke Detectors

Sounder with Strobe


Light Common Areas and Elevator Lobby Graphical Anunciator

Flow Switches Common Areas and near Fire Exit Fireman's Telephone Outlet

All equipment also connected


Third Floor to SFACP with PB in Access
Room 3F-49
Sounder with Strobe
Fire Exits/Common Areas A. Control Module
Light
Flow Switches Fire Exits A. Monitor Modules
A. Heat Detectors with
SPA
sounder

Guest Bedrooms A. Smoke Detectors

Sounder with Strobe


Light Gym/Private Office/Common Areas A. Smoke Detectors

Flow Switches Fire Exits/Common Areas A. Control Module


Fire Exits A. Monitor Modules

SPA A. Heat Detectors with


sounder
Beauty Salon/Living Rooms/Common
A. Smoke Detectors
Areas/Office Rooms
Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

Sounder with Strobe


Light
Flow Switches
A. Manual Pull Station Sounder with Strobe
Light
Supervisory Switches Flow Switches

Sounder with Strobe


A. Manual Pull Station Light
Supervisory Switches Flow Switches

Sounder with Strobe


A. Manual Pull Station
Light

Supervisory Switches Flow Switches

Supervisory Switches Flow Switches

A. Manual Pull Station Sounder with Strobe


Light
Supervisory Switches Flow Switches

Sounder with Strobe


A. Manual Pull Station
Light
Supervisory Switches Flow Switches
A. Smoke Detectors

Sounder with Strobe


A. Manual Pull Station
Light

Supervisory Switches Flow Switches


Sounder with Strobe
A. Manual Pull Station
Light
Supervisory Switches Flow Switches

Sounder with Strobe


A. Manual Pull Station
Light

Supervisory Switches Flow Switches


Sounder with Strobe
A. Manual Pull Station
Light
Supervisory Switches Flow Switches

Sounder with Strobe


A. Manual Pull Station
Light

Supervisory Switches Flow Switches

Line Beam Detectors

Sounder with Strobe


A. Manual Pull Station
Light
Supervisory Switches Flow Switches

Sounder with Strobe


A. Manual Pull Station
Light
Supervisory Switches Flow Switches

Sounder with Strobe


A. Manual Pull Station
Light
Supervisory Switches Flow Switches

Sounder with Strobe


A. Manual Pull Station
Light

Supervisory Switches Flow Switches

Sounder with Strobe


A. Manual Pull Station
Light
Supervisory Switches Flow Switches

Sounder with Strobe


A. Manual Pull Station
Light
Supervisory Switches Flow Switches

A. Smoke Detectors with


sounder

Sounder with Strobe


A. Manual Pull Station
Light
Supervisory Switches Flow Switches
Podium B

All equipment connected to


Basement PB down to SFACP in Access
Room B1-01
Glass Corridor

Stairs A. Control Module A. Manual Pull Station

Parking Areas A. Monitor Modules Supervisory Switches


Parking Areas A. Manual Pull Stations
Enclosed Corridor A. Smoke Detectors

Fire Exits A. Control Module A. Manual Pull Station

Fire Exits/Stairs A. Monitor Modules Supervisory Switches

Parking Areas A. Manual Pull Stations

Access Rooms/Fan Rooms/Driver's


A. Control Module
Lounge

Fire Exits A. Control Module A. Manual Pull Station

Fire Exits/Stairs A. Monitor Modules Supervisory Switches


Parking Areas A. Manual Pull Stations

Access Rooms/Storage Rooms/EE Rooms A. Smoke Detectors

Fire Exits A. Control Module A. Manual Pull Station

Fire Exits/Stairs A. Monitor Modules Supervisory Switches

Parking Areas A. Manual Pull Stations

Access Rooms/Storage Rooms/EE Rooms A. Smoke Detectors

Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

All equipment connected to


Upper Ground Floor SFACP with PB in Access Room
UG-19
Glass Corridor

Fire Exits A. Control Module A. Manual Pull Station

Fire Exits/Common Areas A. Monitor Modules Supervisory Switches


Common Areas A. Manual Pull Stations
High Ceiling Common Area Reflectors Line Beam Detectors
F&B Dining Including 2F A. Smoke Detectors A. Heat Detectors

Fire Exits A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Common Areas/Office Area/Storage
Rooms/Access Rooms/Retail Areas/BOH
A. Smoke Detectors
Rooms/
EE Rooms

Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


High Ceiling Common Area Reflectors Line Beam Detectors
Casino A. Heat Detectors
Common Areas/Office Area/Access
A. Smoke Detectors
Rooms

Fire Exits A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Casino A. Heat Detectors
Common Areas/Office Area/Storage
Rooms/Access Rooms/BOH
Rooms/Cages/Distribution Rooms A. Smoke Detectors
/EE Rooms

Fire Exits A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Casino A. Heat Detectors
Common Areas/Office Area/Storage
Rooms/Access Rooms/Retail Areas/BOH A. Smoke Detectors
Rooms/Cages/EE Rooms
Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

Mimic Panel at Security


Mid-Upper Ground Floor
Control Room
Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

All equipment connected to


Second Floor SFACP with PB in Access Room
2F-35
Fire Exits/Plant Rooms/Common
A. Control Module A. Manual Pull Station
Areas/Exit Doors
Fire Exits A. Monitor Modules Supervisory Switches
AHU A. Control Module
Data Center A. Monitor Modules
Plant Rooms/Kitchens/Garbage A. Heat Detectors
Stations/Employee Smoke Area
Common Areas/Office Area/Storage
A. Smoke Detectors
Rooms/Access Rooms/BOH Rooms

Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Common Areas/Office Area/Storage
A. Smoke Detectors
Rooms/Access Rooms/BOH Rooms

Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Common Areas/Office Area/Storage
A. Smoke Detectors
Rooms/Access Rooms/BOH Rooms

Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Kitchen Dining A. Heat Detectors
Common Areas/Office Area/Storage
A. Smoke Detectors
Rooms/Access Rooms

Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Pantry/Kitchen A. Heat Detectors
Common Areas/Office Area/Storage
A. Smoke Detectors
Rooms/Access Rooms
Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

All equipment connected to


Third Floor SFACP with PB in Access Room
3F-49

Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


AHU A. Control Module
Common Areas/Office Areas/BOH
Rooms/Storage Rooms A. Smoke Detectors

Fire Exits/Common Areas A. Control Module A. Manual Pull Station

Fire Exits A. Monitor Modules Supervisory Switches


Common Areas/Office Area/BOH
Rooms/Storage Rooms/Access A. Smoke Detectors
Rooms/Studio/Board Rooms
Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

All equipment connected per


4F to 15F floor connected to PB which
goes to Access Room 4F-02

Fire Exits/Plant Rooms/Common


A. Control Module A. Manual Pull Station
Areas/Exit Doors
Fire Exits A. Monitor Modules Supervisory Switches
Closet/Living Room/Dining Area
A. Smoke Detectors
(Executive Suite/Pres. Suite)
Kitchen A. Heat Detector
A. Smoke Detector with
Bed Rooms
sounder
Closet/Living Room/Dining Area A. Smoke Detectors
(Junior Suite)

Bed Rooms A. Smoke Detector with


sounder
Closet (Deluxe Suite) A. Smoke Detectors
A. Smoke Detector with
Bed Rooms
sounder

Common Areas/Storage Rooms/Access


A. Smoke Detectors
Rooms/EE Rooms/MEPF Room

Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

All equipment connected per


Roof Deck floor connected to PB which
goes to Access Room 4F-02

SEF/LPF A. Control Modules


Pump Rooms A. Heat Detectors
All equipment connected to
Basement PB down to SFACP in Access
Room B1-05
Glass Corridor
Sounder with Strobe
Stairs/Fan Rooms A. Control Module
Light
Flow Switches Stairs A. Monitor Modules
Access Rooms/Parking Area A. Manual Pull Stations
EF/SF A. Control Module
Sounder with Strobe
Light Fan Rooms A. Control Module

Flow Switches Access Rooms/Fan Rooms A. Smoke Detectros

Stairs/Plant Rooms/Fan Rooms A. Control Module

Fire Exits/Stairs A. Monitor Modules

Sounder with Strobe


Parking Areas A. Manual Pull Stations
Light
Flow Switches Fan Rooms A. Control Module
Access Rooms/Fan Rooms A. Smoke Detectros

Fire Exits/Stairs A. Control Module

Sounder with Strobe Fire Exits/Stairs A. Monitor Modules


Light
Flow Switches Parking Areas A. Manual Pull Stations
Access Rooms/Driver's
A. Smoke Detectros
Lounge/Corridor/EE Rooms

Common Areas and Elevator Lobby Graphical Anunciator

Common Areas and near Fire Exit Fireman's Telephone Outlet

Sounder with Strobe


Light
Flow Switches
Sounder with Strobe
Light
Flow Switches

Sounder with Strobe


Light
Flow Switches

Sounder with Strobe


Light
Flow Switches

Sounder with Strobe


Light
Flow Switches

Sounder with Strobe


Light
Flow Switches

Sounder with Strobe


Light
Flow Switches

Sounder with Strobe


Light
Flow Switches

Sounder with Strobe


Light
Flow Switches

Sounder with Strobe


Light
Flow Switches

Sounder with Strobe


Light
Flow Switches

Sounder with Strobe


Light
Flow Switches
Sounder with Strobe
Light
Flow Switches
Sounder with Strobe
A. Manual Pull Station
Light
Supervisory Switches Flow Switches

Sounder with Strobe


A. Manual Pull Station Light

Supervisory Switches Flow Switches

Sounder with Strobe


A. Manual Pull Station
Light

Supervisory Switches Flow Switches

You might also like