Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Base material Installation


No stand-off Installation.
Cracked Concrete
Thickness of base material 150 mm Anchor plate
Strength Class C35/45 Assumed rigid plate
fck,cube 45 N/mm2 Thickness of the plate 6 mm
Plate shape Circle
Radius 60 mm

Anchors Position

Anchor x y Slotted -x Slotted -y


1 -30.0 30.0
2 30.0 30.0
3 -30.0 -30.0
4 30.0 -30.0

= Slotted

Profile
Selected Profile CIRCULAR HOLLOW Ø 48,3 s 2
Eccentricity X: 0.0 mm
Y: 0.0 mm
Profile rotation 0.0°

Selected Products
Anchor (name) MTP-G anchor
Approval ETA 12/0397
Size M10 x 90
Article code APG10090

-
-

Anclajes / Anchors / Chevilles / Dübel /


22/03/2021 Page: 1 / 8
v. 4.0.3.454 - Database 1333.9.2356174345
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Anchor data
d Anchor/thread diameter: 10.0 mm tfix Thickness of fixture: 6.0 mm
dnom Outside diameter of anchor: 10.0 mm SW Spanner: 17.0 mm
d0 Drill hole diameter: 10.0 mm Tinst Max setting torque 40.0 Nm
h1 Depth of drilled hole: 75.0 mm
hnom Setting depth: 68.0 mm
hef Effective anchorage depth: 60.0 mm
df Diameter of clearance hole in fixture: 12.0 mm

PRODUCT:
MTP-G anchor sherardized.

CALCULATION METHOD:
This calculation method is based in specific values exclusively for MTP-G. Any modifications made --this being change of product
brand or changes in physical conditions of design-- require recalculation of the design

ANCHOR PLATE:
The design program assumes, in accordance with the design code, that the anchor plate does not deform as a result of applied
actions. Thus, in accordance with the design code, the anchor plate shall be sufficiently stiff and its design should be carried out
according to standards for steel structure ensuring elastic behavior.

INSTALLATION:
All conditions of the European Technical Assessment (ETA) and Index technical publications shall be complied with in all details.

ADDITIONAL PROOFS:
With regard to design of anchorages one shall to be aware of the additional proofs for ensuring the characteristics resistance of the
concrete member (structural component) described in the design code.

Anclajes / Anchors / Chevilles / Dübel /


22/03/2021 Page: 2 / 8
v. 4.0.3.454 - Database 1333.9.2356174345
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Input Data
Tension Bending Reinforcement
NSd,Z 0.15 kN MSd,X 1.00 kN·m Diameter 11 mm
Shear MSd,Y 0.00 kN·m Distance rebars 200 mm
VSd,X 0.00 kN Torsion Distance stirrups 200 mm
VSd,Y 1.40 kN MSd,Z 0.00 kN·m Edge reinforcement No
Edges
CXp ∞ mm
CXn ∞ mm
CYp ∞ mm
CYn ∞ mm

Anclajes / Anchors / Chevilles / Dübel /


22/03/2021 Page: 3 / 8
v. 4.0.3.454 - Database 1333.9.2356174345
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Calculated design loads on anchor(s)

Tension force Shear force Shear force (x) Shear force (y)
Anchor
[kN] [kN] [kN] [kN]
1 6.78 0.35 0.00 0.35
2 6.78 0.35 0.00 0.35
3 0.00 0.35 0.00 0.35
4 0.00 0.35 0.00 0.35

Resultant tension force: 13.56 [kN]


Resultant compression force: 13.41 [kN]
Resultant shear force: 1.40 [kN]

Calculation of Utilizations according to: ETAG 001, Annex C - Method A


(β- is the ratio between design load and design resistance)

Calculation of Utilisations - Tension loads

Tension - Steel Failure

NRk,s γM,s NRd,s NSd βN,s


Anchor
[kN] [-] [kN] [kN] [%]

31.40 1.50 20.93 1 6.78 32.4%

2 6.78 32.4%

3 0.00 0.0%

4 0.00 0.0%

Anclajes / Anchors / Chevilles / Dübel /


22/03/2021 Page: 4 / 8
v. 4.0.3.454 - Database 1333.9.2356174345
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Tension - Pull Out Failure

NRk,p γM,p ψc NRd,p NSd βn,p


Anchor
[kN] [-] [-] [kN] [kN] [%]
9.00 1.5 1.23 7.41
1 6.78 91.5%

2 6.78 91.5%

3 0.00 0.0%

4 0.00 0.0%

Tension - Concrete Cone Failure


NRk,c=N0Rk,c · ψA,N · ψs,N · ψre,N · ψec,N

hef scr,N ccr,N fck,cube γMc


[mm] [mm] [mm] [N/mm²] [-]
60 180 90 45 1.5

The anchors are divided into 1 group

Verification performed with three or more edges cmax < ccr

Group N0Rk,c Ac,N A0c,N hef scr,N ccr,N c-x c+x c-y c+y
Anchor
No. [kN] [mm²] [mm²] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

1 [1, 2] 22.45 43,200 32,400 60 180 90 6,000 6,000 6,060 6,000

Group ψs,N ψre,N eN,x eN,y ψec,N NRk,c NRd,c Nsd βN,c
Anchor
No. [-] [-] [mm] [mm] [-] [kN] [kN] [kN] [%]

1 [1, 2] 1.000 1.000 0.0 0.0 1.000 29.93 19.95 13.56 68.0%

Tension - Splitting Failure

As the calculation is performed for cracked concrete, no proof for splitting failure is required.

Anclajes / Anchors / Chevilles / Dübel /


22/03/2021 Page: 5 / 8
v. 4.0.3.454 - Database 1333.9.2356174345
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Calculation of Utilisations - Shear loads


Shear - Steel Failure Without Lever Arm

VRk,s γMs VRd,s


[kN] [-] [kN]

17.40 1.25 13.92

1 2 3 4

Vsd [kN] 0.35 0.35 0.35 0.35

βV,s [ % ] 2.5% 2.5% 2.5% 2.5%

Shear - Steel Failure With Lever Arm

No lever arm has been applied

Shear - Pryout Failure(NRk,c)


NRk,c=N0Rk,c · ψA,N · ψs,N · ψre,N · ψec,V,cp

VRk,cp=k · NRk,c

hef scr,N ccr,N fck,cube k γMc


[mm] [mm] [mm] [N/mm²] [-] [-]
60 180 90 45 2.0 1.5

The anchors are divided into 1 group

Group N0Rk,c Ac,N A0c,N ψs,N ψre,N c-x c+x c-y c+y
Anchor
No. [kN] [mm2] [mm2] [-] [-] [mm] [mm] [mm] [mm]

1 [1, 2, 3, 4] 22.45 57,600 32,400 1.000 1.000 6,000 6,000 6,000 6,000

Anclajes / Anchors / Chevilles / Dübel /


22/03/2021 Page: 6 / 8
v. 4.0.3.454 - Database 1333.9.2356174345
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Group eN,x eN,y ψec,N NRk,c VRk,cp VRd,cp VSd βV,cp


Anchor
No. [mm] [mm] [-] [kN] [kN] [kN] [kN] [%]

1 [1, 2, 3, 4] 0.0 0.0 1.000 39.91 79.81 53.21 1.40 2.6%

Shear - Concrete Edge Failure

As all edges are greater than 10 hef and 60 d, the proof for concrete edge failure is omitted.

Combined tension and shear

Anchor Tension (βN) Shear (βV) Condition Utilisation Status

Steel 1 32.4% 2.5% β = β2N + β2V 10.6%

Concrete 1 91.5% 2.6% β = (βN + βV) / 1.2 78.4%


Anchor

βN,s βN,p βN,comb βN,c βN,sp βV,s βV,sla βV,cp βV,c βN,s,max βV,s.max βN,c,max, βV,c,max,E βcombi,c,E βcombi,S,E
E

1 32.4% 91.5% 0.0% 68.0% 0.0% 2.5% 0.0% 2.6% 0.0% 32.4% 2.5% 91.5% 2.6% 78.4% 10.6%

2 32.4% 91.5% 0.0% 68.0% 0.0% 2.5% 0.0% 2.6% 0.0% 32.4% 2.5% 91.5% 2.6% 78.4% 10.6%

3 0.0% 0.0% 0.0% 0.0% 0.0% 2.5% 0.0% 2.6% 0.0% 0.0% 2.5% 0.0% 2.6% 0.4% 0.1%

4 0.0% 0.0% 0.0% 0.0% 0.0% 2.5% 0.0% 2.6% 0.0% 0.0% 2.5% 0.0% 2.6% 0.4% 0.1%

βN,s,max = βN,s
βV,s,max = max ( βV,s , βV,sla )

Anclajes / Anchors / Chevilles / Dübel /


22/03/2021 Page: 7 / 8
v. 4.0.3.454 - Database 1333.9.2356174345
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

βN,c,max,E = max ( βN,p , βN,c , βN,sp , βN,comb )


βV,c,max,E = max ( βV,cp , βV,c )
βcombi,s,E = β2N,s + β2V,s
βcombi,c,E = min[ ( β1.5N,c,max,E + β1.5V,c,max,E), ( βN,c,max,E + βV,c,max,E ) / 1.2 ]

With consideration of related anchors and separation of steel and concrete failure

RESULT
Ok. The product meets the design criteria

REMARKS
The verification of anchor design cases covered by ETAG 001 or TR29 is performed according to the selected Guideline. The
verification of anchor design cases non-covered by guidelines is based on the selected Guideline. Further information can be
found inside ACP Design Guides. The loads acting on anchors are evaluated according to the theory of elasticity, assuming
that the anchor plate does not deform under the design actions. To ensure the validity of this assumption the anchor plate
shall be sufficient stiff. The user must verify this condition, since the base plate stiffness is not automatically calculated by the
software. The transfer of loads from anchors into base material must be verified in accordance with ETAG 001 Annex C or
TR29 Section 7. The design method is valid only for clearance hole in the fixture with a diameter not larger than the values
given in ETAG 001 Annex C or TR29 Table 4.1.

IMPORTANT NOTICE
The data input to this software, and the relative results, must be checked by the user under the responsibility of an engineer
experienced in anchorages and concrete work. This is to ensure there are no errors and all data is complete and accurate and
complies with all rules and regulations for the actual conditions and application.
The data contained in this software relates only to the product illustrated therein and is based on principles, formulas and
safety regulations according to the existing guidelines for anchorages into concrete, together with the knowledge of the
manufacturer.
The user must comply with these principles. The user is solely responsible for the data entered into the program and any
errors or omissions are the responsibility of the user. The user must ensure that the most current version of the program is
installed by way of the auto-updating function offered by the manufacturer.
The user must update the program when instructed to do so.
The aim of the program is to act as a calculation aid and to assist in complying with current regulations and guidelines,
without any guarantee of suitability for any specific application.

Anclajes / Anchors / Chevilles / Dübel /


22/03/2021 Page: 8 / 8
v. 4.0.3.454 - Database 1333.9.2356174345

You might also like