deutsch
6.7.1 Fuses on device version instructions 49
decentral IP65 42 10.1 Installation space 49
6.7.2 Fuses on device version
10.2 STO wiring 49
central IP20 42
6.7.3 Motor circuit protection 42
10.3 Important information for STO 49
7 Startup and operation 43 10.4 Intended use of STO 50
7.1 Safety instructions 43 10.5 Improper use of STO 50
7.2 Startup software 43 10.6 Technical data and STO pin
7.3 Displays on the drive amplifier 44 assignment 50
7.3.1 LED codes DS 45 10.7 STO pin assignment 50
english
7.3.2 LED codes MS 45 10.7.1 STO device version IP65
7.3.3 LED codes NS 46 decentral SIM20xxD-FC… 50
10.7.2 STO device version IP20
8 Maintenance and disposal 48
central SIM20xxD-CC… 51
8.1 Maintenance work 48
10.8 Function description 52
8.1.1 Maintenance 48
10.8.1 Safe operation sequence 53
8.1.2 Cleaning 48
8.1.3 Visual inspection 48 10.9 Functional check 53
8.1.4 Repairs 48
8.2 Disposal 48
français
italiano
español
日本語
deutsch
General Hot surface Electric Electrostatically
danger voltage sensitive
device
english
Safety information in this manual has been structured according to the following template:
français
1.4 Information symbols
The following information symbols are used:
italiano
español
日本語
2 Safety
This operating manual, especially the safety instructions, and the rules and regulations valid
for the operating site must be observed by all persons working with the drive amplifier.
In addition to the safety instructions in this manual, also observe any legal and otherwise
applicable environmental and accident prevention rules and regulations (e.g. personal
safety equipment).
2.1 Approvals
2.1.1 CE conformity
The drive amplifier was tested in authorized testing laboratories in accordance with the
requirements of this documentation. Deviations and nonconformity with requirements in this
documentation mean that the drive amplifier may not fulfill statutory requirements under certain
circumstances.
In terms of interference immunity, the drive amplifier fulfills the requirement for the category
“second environment” (industrial environment).
In the area of interference emission, the drive amplifier fulfills the requirements for category C3.
deutsch
Explanations:
NRTL: Approval according to standards of the United States in accordance with UL 61800-5-1
Approval according to national Canadian standards in accordance with C22.2 No.
274-13, 1st edition
NRTL Markings:
Maximum Altitude: 2000 m
Maximum Surrounding Air Temperature: IP20 45 °C, IP65 55 °C
These devices are intended to be used in a pollution degree 2 environment
english
Use minimum 90 °C copper wire
Integral Solid State short circuit Protection
Integral solid state short circuit protection does not provide branch circuit protection.
Branch circuit protection must be provided in accordance with the National Electrical
Code and any additional local codes
For Canada (CSA): Integral solid state short circuit protection does not provide branch
circuit protection. Branch circuit protection must be provided in accordance with the
Canadian Electrical Code, Part I
français
Use only UL listed Class G Fuse with a rating of minimum 300 Vdc and max fuse rating
of 25 A and an DC interrupt rating of 10 kA or higher, e.g. Bussmann SC-60.
Alternately use an UL listed fuse with an lower I²t rating of 25 kA and an Ip value of
10.5 kA
Tightening torque for factory wiring terminals: 0.5 Nm
These products are intended for operation within circuits not connected directly to the
supply mains (galvanically isolated from the supply, i.e. on transformer secondary).
This EUT is for use in non-hazardous locations, operated by qualified personell skilled
italiano
in its use.
This EUT shall be supplied with the specified rated voltages according to the user
manual.
The EUT fulfils the requirements of the tested standards only, if it is supplied with
a source that has a prospective short-circuit current of at least 5000 A.
The circuit design has been tested and subsequently assessed by TÜV Süd. According to that
assessment, the circuit design used for the “Safe Torque Off” safety function in the simco drive
series of drive amplifiers is suitable for meeting the requirements for SIL 3 in accordance with
EN 61508 and category 4 PLe in accordance with EN ISO 13849-1:2015.
The subsystems (drive amplifiers) are fully described in terms of safety by the following
characteristics:
Operating mode EN 13849-1 EN 61508 PFHD [1/h]
日本語
2.2 EC directives
The drive amplifier is subject to the following EC directive:
Machinery Directive (2006/42/EC)
Electromagnetic Compatibility (EMC) (2014/30/EU)
RoHS Directive (2011/65/EU)
Startup is prohibited within the scope of the EC directives until it has been determined that the
machine/system in which this drive amplifier is installed corresponds to the regulations within
these directives.
2.3 Commissioning
For installation in machines and systems, start of intended use of the drive amplifier
is prohibited until it has been determined that the machine or system complies with the
provisions of the EC Machinery Directive 2006/42/EC and the EC EMC Directive 2014/30/EU.
For use in residential areas, additional EMC measures are necessary.
It is the responsibility of the manufacturer of the machine or system to ensure that the limit
values, as stipulated by the EMC regulations, are adhered to.
2.4 Hazards
The drive amplifier has been constructed according to current technological standards and
accepted safety regulations.
To avoid danger to the operator or damage to the machine, the drive amplifier may be put
to use only for its intended usage (see chapter 2.6 “Intended use”) and in a technically flawless
and safe state.
2.5 Personnel
Only qualified technicians who have read and understood this manual may carry out work
on the drive amplifier.
Information on the drive amplifier, in particular the safety instructions, must be accessible to all
persons who work with the drive amplifier.
Qualified technicians are characterized by their education and training in the use of electronic
drive technology. They know the relevant standards and accident prevention regulations for
drive technology and can evaluate its use. Potential hazards are recognized immediately.
The local regulations (ICE, VDE, VGB) are known to the technicians and are taken into
account during their work.
In case of ambiguities and functions that are not described or not sufficiently described in the
documentation, the manufacturer or retailer must be contacted.
They are used in industrial environments. For use in residential areas, additional EMC
measures are necessary. The user must prepare a hazard analysis of the final product.
deutsch
In addition, the following applications are excepted from intended use:
2.8 Risks
The manufacturer must strive to reduce residual risks associated with the drive amplifier
english
as much as possible by taking appropriate action. Nonetheless, known residual risks must
be taken into account for the risk assessment of machines and systems.
français
Limited reaction time of the controller
Operation outside of the specifications
Electromagnetic interference, lightning strike
Component failure
Nonconformity in installation
italiano
Incorrect installation site
Nonconformity in electrical protection
Conductive pollution, condensation
español
日本語
Electrical connection work refers to all work on the electrical circuit for which faults and
associated hazards cannot be excluded.
Connecting the power and signal supply lines under voltage is not
permitted and can lead to machine damage, serious injury or even
death.
Make sure that the power supply unit is always in a voltage-free
state before connecting.
deutsch
A F G B H C I D E
J L M N
english
K
O P
Q R
Designation Designation
A Product designation J Intermediate circuit voltage UD
B Type code K Maximum current Imax
C Material number L Continuous stall current In
D TÜV logo M PWM frequency
E CE mark N Protection class
F Data matrix code (DMC) O Ambient temperature
français
G Bus interface P Manufacturer
H Customer material number Q Service portal code
I Calendar week and year of production R Serial number
Table 1: IP20 name plate
A
B C D E F G H I
italiano
J K L M N O
P Q R
Designation Designation
A Product designation J Intermediate circuit voltage UD
B Data matrix code (DMC) K Maximum current Imax
C Type code L Continuous stall current In
D Material number M PWM frequency
español
3.2 Code
Using the following code, the properties of the drive amplifier can be determined.
Hardware:
Firmware:
1
In the case of the mounting position described in chapter 5 and a PWM frequency of 16 kHz, the nominal output
current is achieved. The nominal output current may reduce considerably in the case of other mounting positions.
deutsch
to 1.5 kW.
The different types of housing in the simco® drive series allow for a high degree of flexibility
in installation.
The housing with protection class IP65 enables decentralized assembly, so that the drive
technology can be integrated modularly and flexibly in the machine structure, reducing wiring.
The drive amplifier with protection class IP20 on the other hand is designed for central
installation in the control cabinet.
Depending on the device version, CANopen according to DS402, EtherCAT with CoE,
PROFINET RT/IRT, Ethernet/IP Cip Sync or SERCOS III with FSP Drive is available
as a communication interface.
english
The intelligence is reflected in the wide range of encoder interfaces, such as ENDAT 2.2,
BISS C or Resolver, high resolution current regulation and event logging.
Intuitive startup and diagnosis is possible using the PC-based, MotionGUI 2 graphic user
interface.
français
3.4.2 Digital regulation
Digital d-q current controller (PI) with a sampling rate of up to 32 kHz
Digital position and speed controller (PI) with a sampling rate of 8 kHz
Feed forward control of speed and current possible
Pulse width modulation with a clock rate of 16 kHz
Anti-windup structure for all controllers
italiano
2 programmable galvanically isolated digital outputs, 24 V (short-circuit proof)
Output for controlling a 24 V holding brake (only if logic and/or power supply
voltage >= 24 V DC)
Further requirements regarding TÜV NRTL are listed in chapter 2.1.2 “Conformity with TÜV
NRTL”.
The STO safety function (Safe Torque Off) is used for safe torque shutdown and to reliably
protect drives from restarting. The drive amplifier is fitted with a two-channel STO function
as standard in the basic model.
Instructions for the STO safety function can be found in the appendix
(see chapter 10 “STO safety function instructions”).
deutsch
Immediately notify the carrier, the insurance company, or
WITTENSTEIN cyber motor GmbH in writing of any missing parts or damage.
4.1 Packaging
The drive amplifier is delivered packed in foil and/or cardboard boxes.
Dispose of the packaging materials at the recycling sites intended for this purpose.
Please observe the valid national regulations for waste disposal.
Labeling: Label attached to the outside of the box
english
4.2 Transport
Transportation only in original packaging by qualified personnel
Avoid hard impacts and vibrations
Transport temperature: -20 ... 60 °C, max. 20 K/hour fluctuation
Transport air humidity: Relative humidity max. 95%, non-condensing
If the packaging is damaged, check the drive amplifier for visible damage. Contact the
responsible shipping company
français
The drive system contains components that are sensitive
to electrostatic charge and can be damaged when handled
improperly.
Observe the directives concerning ESD protection.
4.3 Storage
Only store the drive amplifier in the ESD-compliant original packaging
- Storage temperature: -20 ... 50 °C, max. 20 K/hour fluctuation
italiano
- Air humidity: Relative humidity max. 95%, non-condensing
Store the drive system for a maximum of 2 years.
For storage logistics, we recommend the “first in – first out” method.
español
日本語
5 Mechanical installation
5.1 Safety instructions
For the mechanical installation, the ESD information must be observed.
The drive amplifier (control cabinet version) must be protected from fog, water and
penetration of metallic dust in the electrical cabinet.
The drive amplifier must be checked for mechanical damage before installation.
Only install flawless drive amplifiers.
During installation in a control cabinet, sufficient ventilation must be provided.
The operation of drive amplifiers exposed to condensation is not permitted.
deutsch
For tightening torques, see chapter 9.1 “Tightening torques”
english
5.2.5 IP65 ventilation / cooling
Sufficient convection for cooling of the drive amplifier must be ensured at the installation
location.
To avoid overheating, closed installation sites with low volume flow are not suitable for
installation of the drive amplifier.
français
The drive amplifier fulfills the following specifications:
italiano
español
日本語
deutsch
Alternatively, the drive amplifier can be connected to the mounting plate using a screw
connection:
Mounting material: 2 cylinder head screws with hexagon socket ISO 4762 - M 4 – 8.8
Required tool: Inner hexagonal bolt SW 3
For tightening torques, see chapter 9.1 “Tightening torques”
english
français
italiano
5.3.4 IP20 installation space
The central variant of the drive amplifier is designed for installation in the control cabinet.
6 Electrical installation
6.1 Safety instructions
For the electrical installation, the ESD instructions must be observed.
deutsch
Systems that are electrically connected must be properly
secured so they cannot be switched back on and warning
signs must be put up. Installation may only be performed
by trained personnel.
Before startup, it must be checked that the wiring is correct
and is free of mechanical damage. Only drive amplifiers with
english
wiring in flawless condition may be put into operation.
Incorrect voltage, reverse polarity and nonconforming wiring
can damage or destroy the drive amplifier.
Excessive or inadequate protection of the power supply
can damage the cables or the drive amplifier.
To comply with protection class IP65, connections which are
not being used must be fitted with dummy connectors which
are included in delivery.
français
Observe the separate instructions for the STO safety function
(see chapter 10 ”STO safety function instructions”).
italiano
electrical installation work:
- Switch off the power supply.
- Secure against being switched on again.
- Check that there is no voltage.
- Ground and short-circuit.
- Cover neighboring and electrified parts.
Before switching the voltage back on, check that all electrified parts
are equipped with suitable and undamaged contact protection.
Check whether there are protective caps on the plugs. If protective
español
caps are missing, check the plugs for damage and soiling.
The drive amplifier can generate a voltage of up to 60 VDC at the power adapter terminals
for power supply when operating as a generator. The power adapter should be designed for
such operation. Otherwise suitable action must be taken to prevent feedback.
deutsch
label on the drive amplifier:
english
français
Image 6.1: IP65 plug connection
No. Function Connector type on the device Connector type on the cable
X1 Power supply Intercontec itec 915 9-pin, male Intercontec itec 915, 9-pin, female
X2 Output fieldbus CAN: M12 5-pin, female, A-coded CAN: M12 5-pin, male, A-coded
interface
Ethernet-based: M12 4-pin, female, Ethernet-based: M12 4-pin, male,
D-coded D-coded
X3 Input fieldbus CAN: M12 5-pin, male, A-coded CAN: M12 5-pin, female, A-coded
italiano
interface
Ethernet-based: M12 4-pin, female, Ethernet-based: M12 4-pin, male,
D-coded D-coded
X4 USB diagnostic M12 4-pin, female, A-coded M12 4-pin, male, A-coded
interface
X5 Digital M12 8-pin, male, A-coded M12 8-pin, female, A-coded
inputs/outputs
X6 Resolver / Sin-Cos M12 8-pin, female, A-coded M12 8-pin, male, A-coded
encoder interface
X7 Encoder interface M12 12-pin, female, A-coded M12 12-pin, male, A-coded
español
X8 Motor connection Intercontec itec 915 15-pin, female Intercontec itec 915, 15-pin, male
enabled by a wide range voltage input of 12-60 VDC and the possible use of a power source
(logic supply is realized via an internal diode).
Deviating from the standard DIN EN 1175-1 (VDE 0117-1):2011-06 chapter 5.7.3 e), ceramic
capacitors (1000 V; with soft termination) are used instead of Y capacitors between the
housing and DC+/DC-. This way, the risk of a short circuit between DC- or DC+ and the frame
with subsequent fire risk is classified as very low.
Connection diagram IP 65 with one power supply unit for power and logic
SIM20xxD-Fxxx-xxxx...
Power supply/Battery
X1 F1 12-60 VDC
A DC Bus + +48 VDC nom.
Supply
B DC Bus - GND
C Chopper
FE
PLC fieldbus X2 1 Logic+
Master Fieldbus OUT 2 N.C.
3 STO Safety control
M12 4/5-pin 12-60VDC
4 N.C. DOUT
5 STO GND DOUT GND
X3 Itec 915 9-pin
Fieldbus IN
M12 4/5-pin
X4 PC / MotionGUI 2
1 VCC
USB
PLC outputs / 2 D- USB
switches or PLC 3 D+
inputs / 4 GND
actuators M12 4-pin
24VDC X5
6 DIN1
Digital
1 DIN2 inputs & X6 1 COS+
8 DIN3 outputs Resolver / 2 COS-
2 DIN4 Sin-Cos 3 SIN+
encoder 4 SIN-
3 DOUT1 5 REF+
4 DOUT2 6 REF-
24VDC 5 VCC24 7 N.C.
7 GND 8 N.C.
M12 8-pin M12 8-pin
X8
A Phase U U
Motor /
X7 Encoder
B Phase V V
M
1 GND
Encoder C Phase W W
2 VCC
1 GND
3 CLK+
2 VCC5
4 CLK-
3 CLK+
5 DATA+
4 CLK-
6 DATA-
F 7 A+
5 DATA+
6 DATA-
8 A- 7 N.C. F
9 B+ Encoder- 8 N.C.
10 B- emulation 9 TEMP+
11 Z+
10 TEMP-
12 Z- 11 BRAKE+
M12 12-pin 12 BRAKE-
Itec 915 15-pin
Connection diagram IP 65 with two power supply unit for power and logic
deutsch
SIM20xxD-Fxxx-xxxx...
Power supply 12-
X1 F1
60 VDC
A DC Bus + +48 VDC nom.
Supply
B DC Bus - GND
C Chopper
FE
PLC fieldbus X2 1 Logic+
2 N.C. Optional power supply
Master Fieldbus OUT
unit 12-60 VDC
F2
M12 4/5-pin
english
+24 VDC nom.
GND
X3
Fieldbus IN 3 STO Safety control
12-60VDC
4 N.C. DOUT
M12 4/5-pin
5 STO GND DOUT GND
Itec 915 9-pin
PLC outputs /
switches or X4 PC / MotionGUI 2
PLC inputs / 1 VCC
USB
actuators 2 D-
français
USB
3 D+
24VDC 4 GND
X5
6 DIN1 M12 4-pin
Digital
1 DIN2 inputs &
8 DIN3 outputs
2 DIN4 X6 1 COS+
Resolver / 2 COS-
Sin-Cos 3 SIN+
3 DOUT1
encoder 4 SIN-
4 DOUT2
5 REF+
24VDC 5 VCC24
6 REF-
7 GND
7 N.C.
italiano
M12 8-pin 8 N.C.
M12 8-pin
X8
A Phase U U
Motor /
X7 Encoder B Phase V V
M
1 GND
Encoder C Phase W W
2 VCC
1 GND
3 CLK+
2 VCC5
4 CLK-
3 CLK+
5 DATA+
4 CLK-
español
6 DATA-
F 7 A+
5 DATA+
6 DATA-
8 A- 7 N.C. F
9 B+ Encoder- 8 N.C.
10 B- emulation
9 TEMP+
11 Z+
10 TEMP-
12 Z- 11 BRAKE+
M12 12-pin 12 BRAKE-
Itec 915 15-pin
mounting plate
The safety input STO (pin 3+5) is galvanically isolated from the intermediate circuit voltage (pin
A) and the logic power supply (pin 1). UZK or GND (pin B) is not connected with the functional
earth and the housing within the device.
Logic+ Voltage V DC 12 24 60
Current mA DC 200
STO Voltage V DC 12 24 60
Current mA DC 80
1 : SIM2015D
2 : SIM2007D
3 : The chopper switches on at 56 V and off at 52 V as standard (4 V hysteresis, average value 54 V); for
other voltages and settings, please hold backrap with the support.
4 : A minimum braking resistor of 2.2 Ohm with 500 W
nom / 1,400 WPEAK must be used. Lower resistance
values must not be connected, a higher current could destroy the chopper control. Larger resistance
values can be used, thus reducing the chopper peak power accordingly.
The braking resistor must be connected between chopper- and an external connection with
DC+.
deutsch
Power supply 12-60 VDC
X1 A DC Bus +
F1
Supply +48 VDC nom.
B DC Bus - GND
C Chopper
Rbrake
FE F3
1 Logic+ resistor
2 N.C.
3 STO
4 N.C.
5 STO GND
Itec 915 9-pin
english
Image 6.2: Chopper
français
2 N.C.
3 CAN_GND CAN ground reference
4 CAN_H CAN High
5 CAN_L CAN Low
italiano
6.5.3 X3: CANopen fieldbus interface (input)
The CAN ground reference is identical to the logic ground reference.
deutsch
drive amplifier.
An external power supply must be connected to supply the digital outputs.
The digital outputs are galvanically isolated from the logic and power of the
drive amplifier.
The digital outputs are short-circuit proof.
english
8 DIN3 Digital input 3 Input
2 DIN4 Digital input 4 Input
7 GND Ground reference
3 DOUT1 Digital output 1 Output
4 DOUT2 Digital output 2 Output
5 VCC24 Digital output Input
supply
français
Connection Feature Unit Minimum Nominal Maximum
value value value
DINx Input voltage V DC 20 24 28
Input current mA DC 3 4 5
Input resistance kOhm 5.6
Sample time msec 1
DOUTx Output voltage V DC 18 24 26
Output current mA DC 40
Output resistance kOhm 1 1.5 2
italiano
Refresh rate Hz 1
VCC24 Voltage V DC 20 24 28
Current mA DC 80
GND Ground reference
español
日本語
Via the encoder interface X7, fully digital encoder systems with the protocols
EnDat 2.2 and BISS C can be evaluated.
The encoder interface has a 5 V power supply, secured with a self-resetting fuse,
with a current rating of 500 mA.
deutsch
isolated from the power of the drive amplifier.
english
3 CLOCK+ Clock signal Output
4 CLOCK- Clock signal Output
inverted
5 DATA+ Data signal Input
6 DATA- Data signal inverted Input
7 Z+ Z trace +
8 Z- Z trace -
9 TEMP+ Motor temperature Input
sensor +
français
10 TEMP- Motor temperature Input
sensor -
11 BRAKE+ Holding brake + Output
12 BRAKE- Holding brake - Output
Plug type on drive amplifier: Intercontec itec 915, 9-pin, female
(EEGA 205 NN00 00 0008 000)
italiano
VCC5 Voltage V DC 4.5 5 5.5
Current mA DC 500
BRAKE+/- Voltage V DC 24
Current A DC 0.8
1
: SIM2015D
2
: SIM2007D
español
日本語
X3 X1
X6 X7 Resolver / Sin-Cos encoder
Power
Fieldbus IN Fieldbus OUT
X5
6789
USB
12345
X2
Logic
1 Logic +
2 STO
X9 3 STO GND
Brake/temperature
1 TEMP+
2 BRAKE+
3 TEMP-
X4
4 BRAKE- Encoder
11 15
6 10
X8
1 5
Digital I/O
8 DOUT2
7 DOUT1
6 DIN4
5 DIN3
4 DIN2
X10 3 DIN1
2 GND
1 VCC24
Motor
1 Phase U
2 Phase V
3 Phase W
4 FE
Connection diagram IP 20 with one power supply unit for power and logic
deutsch
SIM20xxD-Cxxx-xxxx...
PLC Fieldbus
Safety control X2 X6 Master
12-60VDC
1 LOGIC +
Supply Fieldbus IN
DOUT 2 STO
DOUT GND 3 STO GND RJ45
Dinkle
ECH350V-03PL
X7
X1 Fieldbus OUT
1 DC Bus +
Power supply/Battery Supply RJ45
english
F1 2 DC Bus -
12-60 VDC
+48 VDC nom. 3 CHOPPER -
GND 4 FE
français
4 DIN 2
6 REF - 3 DIN 1
7 N.C. 2 GND
8 N.C. 1 24VDC
SUB-D
9 N.C. 24VDC
9 pin Dinkle 0225-3708L
X4
1 GND
Encoder X9
2 VCC 1 TEMP +
Temp /
3 CLK+ Brake 2 BRAKE +
4 CLK- 3 TEMP -
5 DATA+ 4 BRAKE -
italiano
6 DATA-
Dinkle 0159-3204L
7A+
F 8A-
Encoder-
9B+
10 B - emulation X10 1 Phase U U
11 Z + Motor 2 Phase V
3 Phase W
V
W
M
12 Z -
13 N.C. 4 FE
14 N.C. Dinkle 5EHDVC-04PL
15 N.C.
español
SUB-D
15-pin
PC / MotionGUI 2 X5
1 VCC
USB
2D-
USB
3D+
4 GND
A-type
Mini-B
日本語
Connection diagram IP 20 with two power supply unit for power and logic
Optional auxiliary
supply 12-60 VDC
SIM20xxD-Cxxx-xxxx...
F2 PLC Fieldbus
+24 VDC nom.
X2 X6 Master
GND 1 LOGIC+ Supply
Fieldbus IN
2 STO
Safety control 3 STO GND RJ45
12-60 VDC
DOUT Dinkle
ECH350V-03PL
DOUT GND X7
X1 Fieldbus OUT
1 DC Bus +
Power supply Supply RJ45
F1 2 DC Bus -
12-60 VDC
+48 VDC nom. 3 CHOPPER -
GND 4 FE
X4
1 GND X9
Encoder
2 VCC 1 TEMP +
Temp /
3 CLK+ Brake 2 BRAKE +
4 CLK- 3 TEMP -
5 DATA+ 4 BRAKE -
6 DATA-
Dinkle 0159-3204L
7A+
F 8A-
9 B + Encoder-
10 B -
emulation X10 1 Phase U U
11 Z + Motor 2 Phase V V
W
M
12 Z - 3 Phase W
13 N.C. 4 FE
14 N.C. Dinkle 5EHDVC-04PL
15 N.C.
SUB-D
15-pin
PC / MotionGUI 2 X5
1 VCC
USB
2D-
USB
3D+
4 GND
A-type
Mini-B
deutsch
of the drive amplifier, the housing of the drive amplifier must be connected to the control
cabinet's functional earth with low impedance.
When mounting the drive amplifier on a metallic and conductive top-hat rail it must
be ensured that the top-hat rail is connected to the control cabinet's functional ground
with sufficiently low impedance.
english
If the drive amplifier is not sufficiently grounded, this may cause
radio interference, leading to non-conformity with the EC EMC
Directive. This can result in malfunctions in the drive amplifier and
other electronic systems.
français
of EMC is using a metal cable tie or using the shield clamp available as an accessory.
italiano
español
日本語
Power connector X1
STO Voltage V DC 12 24 60
Current mA DC 80
DCBus+ / - Voltage V DC 12 48 60
Current A DC 301 / 152
The braking resistor must be connected between chopper- and an external connection with
DC+.
deutsch
1 DC Bus +
X1
Power supply Supply
12-60 VDC F1 2 DC Bus -
+48 VDC nom. 3 CHOPPER -
GND 4 FE
Rbrake
F3 Dinkle
resistor
5EHDVC-04PL
english
6.6.6 X3: Resolver / Sin-Cos encoder
français
6 REF- Reference trace R2 Output
7 N.C.
8 N.C.
9 N.C.
italiano
Plug type on drive amplifier: D-Sub, 9-pin, female
deutsch
Figure Pin Signal Function
no.
J1 CAN_H CAN High
X6 X7 J2 CAN_L CAN Low
Fieldbus IN Fieldbus OUT
J3 CAN_GND CAN ground
reference
J4 N.C.
J5 N.C.
J6 N.C.
english
J7 N.C.
J8 N.C.
français
Connection Feature Unit Minimum Nominal Maximum
value value value
Baud rate kbaud 100 500 1000
italiano
J1 RD+ Receive Data +
X6 X7 J2 RD- Receive Data -
Feldbus IN Feldbus OUT
J3 TD+ Transmit Data +
J4 N.C.
J5 N.C.
J6 TD- Transmit Data -
J7 N.C.
J8 N.C.
español
The digital outputs are galvanically isolated from the logic and power of the
drive amplifier.
The digital outputs are short-circuit proof.
deutsch
Motor plug X10
Brake/temperature plug X9
english
1 TEMP+ Motor temperature sensor +
2 BRAKE+ Holding brake +
3 TEMP- Motor temperature sensor -
4 BRAKE- Holding brake -
français
Plug type X10 on Dinkle 0181-A303
Permissible wire cross-section: AWG 24..12
Stripping length: 8 mm
Tightening torque: 0.5 ... 0.6 Nm; the tightening torque must be 0.5 Nm to conform to the
UL requirement
italiano
Connection Current A DC 0.8
1
: SIM2015D
2
: SIM2007D
The following overview shows the correct wiring of the motor phases of cyber® dynamic line
via the adapter cables S/L-cable xxxHI-xxxx-BA0-6/3:
Connection schematic
U Red
V White
español
W Black
日本語
6.7 Fuses
6.7.1 Fuses on device version decentral IP65
The power supplies are to be secured with the fuses specified in the table:
Fuses
Logic supply (F2) Fuse or similar with max. 4 AT
X1 (pin 1)
Power supply (F1) Fuse or similar with max. 16 AT
X1 (pin A)
Brake chopper (F3) Fuse or similar with max. 10 AT
X1 (pin C)
Fuses
Logic supply (F2) Fuse or similar with max. 4 AT
X1 (pin 1)
Power supply (F1) Fuse or similar with max. 16 AT
X2 (pin 1)
Brake chopper (F3) Fuse or similar with max. 10 AT
X2 (pin 3)
deutsch
Connection and operating instructions
Local regulations
EC regulations and the EC Machinery Directive
english
Wait until the housing temperature has cooled down
to 40 °C before touching the drive amplifier.
français
Only technicians with extensive experience with electrical
and electronic systems and drive technology may start up
the drive amplifier.
italiano
as well as an interactive, html-based guide.
The startup software MotionGUI 2 is used to change and save the operating parameters of
the drive amplifier. The connected drive amplifiers can be put into operation with the help
of software.
In the html-based help, all parameters and the functions of the drive amplifier are described. español
deutsch
Status LED DS Meaning
LED
Off Drive amplifier has no power supply or
drive is defective
english
Flash: Drive amplifier is in fault state and output
Red stage is disabled
français
Green output stage is enabled
italiano
EtherCAT: LED MS indicates the EtherCAT state machine state
deutsch
LED
Off The bus module has no IP addrress (or
has no power supply or is defective)
english
Flash: An IP address is configured but the
Red timeout limit was exceeded
français
PROFINET: LED NS (BF) indicates the bus failure
italiano
Constant: No configuration; or low speed physical
Red link; or no physical link
español
日本語
8.1.1 Maintenance
The drive amplifiers are maintenance free. Opening the drive amplifier voids the warranty.
8.1.2 Cleaning
Clean the drive amplifier IP65 with a grease-dissolving, non-aggressive detergent.
8.1.4 Repairs
The drive amplifier may only be repaired by the manufacturer. Opening the drive amplifiers
voids the warranty and safety according to the specified standards is no longer ensured.
8.2 Disposal
In accordance with WEEE 2002/96/EC directive, we take back old equipment for proper
disposal as long as the transport costs are paid by the sender.
9 Appendix
M 3.5
M 10
M 12
M 14
M 16
M 18
M 20
M 22
M 24
M3
M4
M5
M6
M8
8.8 1.28 1.96 2.9 5.75 9.9 24 48 83 132 200 275 390 530 675
10.9 1.8 2.75 4.1 8.1 14 34 67 117 185 285 390 550 745 950
12.9 2.15 3.3 4.95 9.7 16.5 40 81 140 220 340 470 660 890 1140
Table 15: Tightening torques
deutsch
as standard in the basic model.
english
The STO safety function equates to stop category 0 (uncontrolled stoppage) defined by
EN 60204-1. The STO safety function of the server amplifier can be triggered by external
safety relays or by an external safety control with safe outputs.
The circuit design has been tested and subsequently assessed by TÜV. According to that
assessment, the circuit design used for the “Safe Torque Off” safety function in the simco
drive series of drive amplifiers is suitable for meeting the requirements for SIL 3 in
accordance with EN 61508 and category 4 PLe in accordance with EN ISO 13849-1:2015.
français
A drive amplifier in protection class IP20 design should be installed in a space that will ensure
reliable operation of the drive amplifier. The installation space must meet the requirements
of protection class IP54 at least.
italiano
10.3 Important information for STO
If the STO function is actuated during operation, the drive will coast
to a stop in an uncontrolled manner and the drive amplifier reports
the “Error_amp_sto_active” fault. Controlled braking of the drive
will not be possible.
If an application requires controlled braking before the use of STO,
español
the drive must first be braked under control and then the STO
function must be triggered with a time delay.
deutsch
X2 +24V
2 STO SIL 2
3 STO GND Cat. 3 PLd
Safety Unit
GND
english
SIL 3 / category 4 PLe:
X2 +24V
2 STO SIL 3
français
3 STO GND Cat. 4 PLe
Safety Unit
GND
italiano
español
日本語
When wiring the STO inputs inside an installation space, make sure
that both the wiring used and the installation space itself meet the
requirements of EN 60204-1.
If the wiring is outside the installation space, it must be routed
in a permanent installation and protected from external damage.
deutsch
1. Controlled braking of drive
2. Once standstill is reached, disable the drive amplifier
3. In the case of a suspended load, mechanically lock the drive as well
4. Trigger STO
The drive amplifier cannot hold the load with the STO function
english
activated because the motor no longer supplies any torque.
Risk of injury from suspended load.
Drives with a suspended load must be securely locked mechanically
as well (e.g. with a suitable holding brake)
If the STO function is actuated during operation, the drive will coast
to a stop in an uncontrolled manner. Controlled braking of the drive
français
will not be possible. Danger from uncontrolled movement.
The STO function must be checked at initial startup, after any work
on the system's wiring, and after replacing one or more components
italiano
of the system.