Acceleration Head calculations

ha= L*V*N*C/ (K*g)


ha Acceleration head in Meter 6.75 Meter
L Length of liquid supply line 20 Meter

C Quintuplex single or double-acting 0.04

K Amine, glycol, water 1.5

V Average Velocity in m/sec 3.10 m/ sec


N Pump speed in (RPM/60) 40 RPS
g Gravitional constant 9.8 m/sec 2
Q Flow rate 0.1 m3/sec
D Nominal pipe size Diameter 8 inchs

SCH Pipe Schedule SCH 40

A Area of the Pipe 0.0323 m2


OD Outside Diameter of the Pipe 219.10 mm
THK Thickness of the Pipe 8.18 mm

ID Inner Diameter of the Pipe 202.74 mm


LINE
PIPE
DIMEN
Nominal Size SIONS
SCH SCH SCH SCH SCH SCH SCH SCH SCH SCH
NB inch OD 10 20 30 STD 40 XS 60 80 100 120 140 160 XXS
15 0.5 SCH 10 21.3 2.27 2.27 3.73 3.73 4.78 7.47
20 0.75 SCH 20 26.7 2.87 2.87 3.91 3.91 5.56 7.82
25 1 SCH 30 33.4 3.38 3.38 4.55 4.55 6.35 9.09
32 1.25 STD 42.2 3.56 3.56 4.85 4.85 6.35 9.70
40 1.5 SCH 40 48.3 3.68 3.68 5.08 5.08 7.14 10.15
50 2 XS 60.3 3.91 3.91 5.54 5.54 8.74 11.07
65 2.5 SCH 60 73.0 5.16 5.16 7.01 7.01 9.53 14.02
80 3 SCH 80 88.9 5.49 5.49 7.62 7.62 11.13 15.24
100 4 SCH 100 114.3 6.02 6.02 8.56 8.56 11.13 13.49 17.12
125 5 SCH 120 141.3 6.55 6.55 9.53 9.53 12.70 15.88 19.05
150 6 SCH 140 168.3 7.11 7.11 10.97 10.97 14.27 18.26 21.95
200 8 SCH 160 219.1 6.35 7.0 8.18 8.18 12.70 10.31 12.70 15.09 18.26 20.62 23.01 22.23
250 10 XXS 273.1 6.35 7.8 9.27 9.27 12.70 12.70 15.09 18.26 21.44 25.40 28.58 25.40
CELL
300 12 LINK: 5 323.9 6.35 8.4 9.53 10.31 12.70 14.27 17.48 21.44 25.40 28.58 33.32 25.40
350 14 355.6 6.35 7.92 9.5 9.53 11.13 12.70 15.09 19.05 26.83 27.79 31.75 35.71
400 16 406.4 6.35 7.92 9.5 9.53 12.70 12.70 16.66 21.44 26.19 30.96 36.53 40.49
450 18 457 6.35 7.92 11.1 9.53 14.20 12.70 19.05 23.83 29.36 34.93 39.67 45.24
500 20 508 6.35 9.53 12.7 9.53 15.09 12.70 20.62 26.20 32.50 38.10 44.40 50.00
600 24 610 6.35 9.53 14.3 9.53 17.48 12.70 24.61 31.00 38.90 46.00 52.40 59.50
12 OD 219.1 Table 1 THK 8.18 ID 202.74
C = a factor related to no. of displacers k = a factor related to the fluid compressibility
Simplex single-acting 4 Hot Oil 2.5
Simplex double-acting 0.2 Most hydrocarbons 2
Duplex single-acting 0.2 Amine, glycol, water 1.5
Duplex double-acting 0.115 Deaerated water 1.4
Triplex single or double-acting 0.066 Liquid with small amounts of entr 1
Quintuplex single or double-acting 0.04
CELL
Septuplex single or double-acting 0.028 LINK: 3 K 1.5
Nonuplex single or double-acting 0.022
CELL
Table 2 LINK: 6 C 0.04 hassan