OXYGEN PRODUCTION SYSTEMS
INSTALLATION AND OPERATION
PRINCIPLE
Oxygen generators should be operated in a completely clean and heated environment.
OXYATA series generators can work between 5 - 45o C (41-113 °F) but they give their best performance
between 20 - 35 °C (68-95 °F). Also, OXYLIFE series generators can work between 5 - 60°C (41-113 °F)
but they give their best performance between 20-40°C (68-104 °F).
Installa on is very easy for the user in "Plug and Play" principle. The most important aspect that affects the
performance of O2 generators is clean and dry air. In order to obtain quality oxygen, the layout given below should
be complied with and recommended products should be used.
1 5 7
6
2
3 8
2292 3
OXYLİFE SERIES 95% PURE
OXL-50 3 m3/h
OXL-100 6 m3/h
OXL-150 9 m3/h
OXL-200 12 m3/h
OXL-250 15 m3/h
OXL-300 18 m3/h
OXL-400 20 m3/h
OXL-500 25 m3/h
OXL-600 30 m3/h
OXL-720 40 m3/h
OXL-900 50 m3/h
OXL-1200 64 m3/h
OXL-1500 85 m3/h
OXL-2000 100 m3/h
4 2292
Oxygen Produc on Line
(1)Rotary-Screw Compressor (5)PLC control
•Produces the pressurized air that feeds the oxygen producer •Based on robust PLC architecture and high precision colored touch-screen panel
•It is designed for 24 hours working principle. •Check of oxygen generator and monitoring of whole installation,
•with the energy-saving motor to reduce energy costs •Long-term data records for analyses, controls and audit records
(2)Air processing line •Historical records of system values
•Quality cooled dryer that provides dry pressurized air according to ISO8573-1. •Administration of permutations between oxygen generators for multiplex installations
•Air filter that provides clean, non-fat pressurized air with minimum pressure drop. •Remote access and monitoring via internet, telephone network
•Condense separator that protects the filters and provides minimum air loss (6)Oxygen acceptor
•Compliant with European Pressure Equipment Directive (PED) EC97/23-Oxygen group 1
•+3°C pressure, humidity point
•It is confirmed for oxygen with "Oxygen" stamp and production certificate.
(3)Air eliminator
(7)Sterile medical grade filter
•Europe Pressure Equipment Directive (PED) EC97/23
•Stainless steel housing
•Long service life
•Accurate filtration rate <0.01um
(4)Medical oxygen generator
•Bacteria handling higher than 107 CFU/cm2
•Providing medical oxygen in compliance with Europe Farmaccpeiave USP
(8)Communication
•Air filter that provides non-fat, clean air with minimum pressure loss
• control can be accessed via any computer network, internet or telephone network.
• Messages can be sent to the mobile phones of service technicians.
Assigned iPhone/iPad applications are available for remote monitoring.
2292 5
AIR
ISO 8573-1
configuration
of oxygen source
BACKUP 1
FROM
OXYGEN GENERATOR
OPTIONAL
TUBE FILLING
SYSTEM
BACKUP 2
6 2292
with continuous
measurement and analysis
O2 % of CO/CO2 O2 dewpoints
CO/CO2
H2 O
OXYGEN
LPM
Connection to hospital
control system
OXYGEN QUALITY
OXYGEN
CONTROL
GENERATOR
Remote control and help
OVER
SYSTEM
AUTOMATIC
CHANGE
TO HOSPITAL NETWORK
It allows for filling your own tube between 150-200 bar pressures.
It is ideal solution for user if the hospital does not have a central oxygen installation.
Hospitals that use medical oxygen production system allow for the filling of spare tubes.
2292 7
Oxygen Generator
O2 Tank
Medical Filter
Group
Active Carbon
Tower
8 2292
Air Compressor
Air Tank
w w w. a t a s a m . c o m . t r
Air Dryer
2292 9
10 2292
CONTAINER
SYSTEM
2292 11