Download as pdf or txt
Download as pdf or txt
You are on page 1of 24

3060/70 - 3080/90 - 7080/90PD

INTRODUCTION
For 80 years in the Brazilian agricultural sector, JUMIL is a company recognized in the market for offering
profitable and innovative solutions, that aim to significantly increase of their customer productivity.

Tis mission, in addition to effective investments in technology, have made the company to develop a great
capacity of adaptation due to the demands required by the national and international markets.

JUMIL is genuinely Brazilian, independent and has a wide knowledge with regards to the type o soil and
its particularities. Thus, it is possible to launch specific products to leverage the volume or productions in all types of
crops. Today, JUMIL ranks as one of the main companies of agricultural implements all over the world and precursor of
agribusiness, exporting their products to more than 36 countries.

SAC - Customer Service - only for critics, praises and suggestions:


0800-215-8645
PABX - other Sectors:
(55) 16 3660-1000

3
3060/70 - 3080/90 - 7080/90PD

TABLE OF CONTENTS
PRODUCT PRESENTATION.............................................................................................................7
EASYTECH SYSTEM........................................................................................................................7
INTRODUCTION................................................................................................................................7
1 - SYSTEM OVERVIEW...................................................................................................................8
1.1 - Easytech Controller Functions...................................................................................................8
2 - INSTALLING THE EASYTECH.....................................................................................................8
2.1 - Electrical Installation..................................................................................................................8
2.2 - Hydraulic Installation..................................................................................................................9
3 - SYSTEM OPERATION..................................................................................................................9
3.1 - Easytech System Interface........................................................................................................9
3.2 - Seed Configuration...................................................................................................................10
3.3 - Manure Configuration and Calibration......................................................................................10
3.4 - Brachiaria Gauging...................................................................................................................13
3.5 - Pneumatic Springs Configuration..............................................................................................14
3.6 - Stop Motors Function................................................................................................................14
3.7 - Deposits Volumetric Reference.................................................................................................15
3.8 - Seeds Monitoring......................................................................................................................15
3.9 - Machine A or B Section Manual Power Off...............................................................................16
3.10 - Operational Clock....................................................................................................................17
3.11 - Machine Under Transportation Warning..................................................................................17
4 - SYSTEM CONFIGURATION........................................................................................................17
4.1 - Modo de teste - RPM dos Motores...........................................................................................18
4.1.1 - Test mode - Seeds Monitor....................................................................................................19
4.1.2 - Test Mode - Pneumatic Suspension.......................................................................................19
4.2 - Planter Adjustment....................................................................................................................20
5 - OCCURRENCES, POSSIBLE CAUSES AND SOLUTIONS.......................................................21

5
3060/70 - 3080/90 - 7080/90PD

PRODUCT PRESENTATION
EASYTECH SYSTEM
Joining simplicity and high technology together, in 2014 JUMIL, as a pioneer in this agricultural practice, has
developed and launched the Easytech system, which came to make the rural producer’s life easier in the field.

Easytech JUMIL is a fixed rate control system, which does not make use of GPS. It controls the equipment,
the fertilizers distribution, both in wagons, seeders/fertilizers, through hydraulic motors and an electronic controller, mi-
nimizing the vibrations in seeders/fertilizers making the operation more accurate and efficient.

Its simple interface enables a quick and dynamic handling. You can adjust the seeds and manure quantity and
adjust the pneumatic springs pressure for the planting units with just one touch. Be prepared for the technology.
INTRODUCTION
This manual contains important information on how to install, configure and use the Easytech system for the
seeders / fertilizers of models 3060/3070PD, 3080/90PD and 7080/90PD.

To assure the Easytech system perfect operation, read this user manual carefully before power on/use the
equipment.

JUMIL - JUSTINO DE MORAIS, IRMÃOS S.A.


Batatais - SP

PRODUCT PRESENTATION
7
Easytech - planting

1 - SYSTEM OVERVIEW
The Easytech controller is a Planter/Fertilizer management system, it has many other complimentary func-
tions that assist and facilitate operations in the field.
1.1 - Easytech Controller Functions

- Fixed rate control Seed;


- Fixed rate control Manure;
- Pneumatic springs control (optional);
- Seed monitoring row per row;
- Manual Power Off of Machine Section A or B (combine);
- Brachiaria Rate Checking Procedure;
- Speed indicator;
- Seeds deposit volumetric reference;
- Manure seeds deposit volumetric reference;
- Hour meter;
- Hectare meter;
- Operational yield report;
- Planting excessive speed warning;
- Operational non-compliance warning.

2 - INSTALLING THE EASYTECH


Make sure that all the electronic components and cables are properly secured and away from the machine
moving parts that might damage them. Cables can not be cut, twisted or excessively bent because the system can
present failures.
ATTENTION:
The Easytech system installation in the tractor must be performed by qualified and trained personnel.
2.1 - Electrical Installation

1st Step: Identify the power cable C1 and connect it in the tractor’s battery positive and negative poles;
2nd Step: Connect the battery cable C1 to the output cable of display MD3;
3rd Step: Connect the implement cable in the two outputs remaining of the cable in the display.

ATTENTION:
For the Easytech system perfect operation, it is necessary that the tractor has a hydraulic output specific
for the transmission hydraulic motors with nominal continuous flow of 35 L/min for single machines and 70 L/
min for combine machines. In addition, there is still also the flow designed to the vacuum turbines, in the case
of Pneumatic distributors (Exacta System) more the demand for the hydraulic lifting pistons and marker arms.

SYSTEM OVERVIEW
8
3060/70 - 3080/90 - 7080/90PD

2.2 - Hydraulic Installation

According to:

3 - SYSTEM OPERATION
It is recommended to power on the tractor before the Easytech display is switched on.
ATTENTION:
The Easytech should be used only by people qualified/trained on the correct use of the equipment. Its
incorrect operation can cause physical damage to the system or any component. Incorrect system configurations
can also cause functional damages due to the equipment malfunctioning.
3.1 - Easytech System Interface
WORK LIFTED BATTERY
IDENTIFICATION MACHINE WARNING REFERENCE

DISPLACEMENT MANURE
SPEED DEPOSIT
LEVEL

SEED
DEPOSIT IDEAL SPEED
LEVEL REFERENCE

SEEDS
RATE LEVEL
ADJUSTMENT

MANURE PNEUMATIC SPRINGS


RATE PRESSURE

SYSTEM OPERATION
9
Easytech - planting

3.2 - Seed Configuration

To configure the seed rate to be applied, click on the function in the work main screen.
Checking the seeds volume:

CURSOR

SELECT

CURSOR

BACK
BECKER

MENU

In the field Seeds in 50ml enter the number of seeds collected in the Becker that comes with the machine.
This value is important for the seeds deposit volumetric reference.
ATTENTION:
For the seeds deposit volumetric reference ideal operation, make sure that the collected value is related
to the volume requested in the display. It is recommended that the value entered is the average of 3 samples
and that the procedure is redone whenever there are any changes in the type or seed sieve used.
In the field Rate, enter the number of seeds per meter to be distributed per row;

In Seed disc, select the quantity of holes of the disc that is being used;

In Target speed, enter the desired speed to perform the work. (NOTE: This value serves only as reference for
the statistics of excessive speed during the planting);

Also observe that in the function we have available the following complimentary information to the
operator.

Population: Population of plants per hectare;

Maximum Capacity: Operational yield according to the target speed established expressed in hectares per
worked hour;

Spacing: Distance between planting rows that is being used in the seeder.
3.3 - Manure Configuration and Calibration

To configure the manure rate to be applied, click on the function in the work main screen.

SYSTEM OPERATION
10
3060/70 - 3080/90 - 7080/90PD

START CALIBRATION
PROCEDURE

To start the calibration procedure, enter the desired rate to be distributed per hectare in the field Manure Rate
and then click on .
ATTENTION:
Before beginning the calibration procedure, make sure that all the manure distributors are not clogged
/ stuffed with any impurity that might impair the material collection.

When clicking on a warning will be displayed to position the collectors (plastic bags and buckets) in
the manure distributors and then press to start the procedure.

The manure deposit volume occurs automatically after its calibration.


ATTENTION:
Make sure that the hydraulic command is driven and that the tractor is in working rotation. For this
procedure, it is recommended that all the seeder / fertilizer lines are collected.
When starting the calibration, only the manure trans-
mission will spin, pouring the product in the collectors that
were previously positioned. The transmission will stop only
when the reference bar reaches its end.
NOTE:
In average, each line will be falling
approximately 1 kg.

SYSTEM OPERATION
11
Easytech - planting

If anything wrong occurs, immediately press


to cancel the procedure and the transmission stops spinning.
As soon as the procedure is concluded, a new war-
ning will be displayed informing that the collection was conclu-
ded and that all the collected material should be weighted and
inserted in the next screen.
To conclude, click on .

After concluding the calibration process, collect all the material and weight it with the assistance of a precision
scale.
Enter the value of the sum generated of all the collected lines in the field Total Collected and inform the quan-
tity of lines collected in No. of rows collected.
NOTE:
The function (validate result) will be displayed only after the end of the calibration procedure
and the checking of the values entered compatible with the reality that should have been collected .

VALIDATE RESULT
AFTER CALIBRATION
(hold for 1 second)

To validate the result, click and hold the function for 1 second, then a warning will be displayed.

SYSTEM OPERATION
12
3060/70 - 3080/90 - 7080/90PD

Make sure that the procedure was correct and vali-


date the result clicking on (Yes) in the function again.
If you are not sure of the procedure performed, click on (No) in
the function .

To confirm the calibration, click on .

3.4 - Brachiaria Gauging


NOTE:
This function will be enabled only in machines that have brachiaria deposit.
This procedure serves only for reference purposes to know if the brachiaria dosers opening are adjusted cor-
rectly according to the desired rate and configured in the display.
To start the checking procedures for the rate applied to each brachiaria, click on the function (“adjust”)
that is inside the similar configuration function.

When you click on a new procedure is dis-


played.

In this stage, place the collectors (plastic bags or buckets) at the brachiaria dosers exit, making sure that the
hydraulic command is actuated and that the tractor is in working rotation.
After placing the collectors, enter the brachiaria rate that you intend to apply. Clique on to start the
gauging procedure.

SYSTEM OPERATION
13
Easytech - planting

NOTE:
In this procedure, only the seed transmission shaft
will spin. After the end of the collection time, it will stop by
itself.
After the samples have been collected, weight them
individually and compare the results with the reference on the
display “Doser adjustment to obtain”.
Example: 12.5 grams per row

NOTE:
If the real weight collected is outside the value
informed on the display, change the position of the
brachiaria dosers scale physically in order to obtain the
same technical value informed during the brachiaria box
gauging procedure.
Repeat the process until the practical value
collected matches with the theoretical value informed.
3.5 - Pneumatic Springs Configuration

To adjust the pneumatic springs pressure, in the work screen click on . Change the desired pressure

using the side cursors and then click on to confirm the desired working pressure.

ATTENTION:

The compressor will operate only when necessary.


For that, the relay should be enabled in the function
and not disabled .

3.6 - Stop Motors Function

Activate and deactivate motors:


This function assists the Operator to pause the manure and seed transmission instantaneously. To
release the function Stop Motors, press the button again.

SYSTEM OPERATION
14
3060/70 - 3080/90 - 7080/90PD

SYMBOL FOR STOP


MOTOR

STOP MOTOR ACTUATION BUTTON

In the main screen, press to power on the motors.

3.7 - Deposits Volumetric Reference


The Easytech system has two volumetric indicators for seed and manure deposits available to
the operator.

These indicators show the moment in which the operator should pay attention to the seed or manure

refilling.
To inform how much material is in the deposits, click in the work screen in to select the desired deposit

and use the side cursors to change the markers level. To confirm, click on .

For further information, read the item 3.2 - Seed Configuration.

ATTENTION:
For the perfect operation of these references, it is extremely important that both the manure calibration
procedure and the filling in of the field Seed in 50 ml (practical counting of the quantity of seeds that a recipient
of 50 ml can hold), are made correctly.
3.8 - Seeds Monitoring
To enter in the seed monitoring function, click in the work screen in .
During the work, if there are any irregularities in the planting lines, a sound warning will be issued highlighting
in red which line has a problem.
SYSTEM OPERATION
15
Easytech - planting

Function indicators

(green color) - Rows OK.

(red color) - Rows with problem.

(yellow color) - Attention: Temporary failure in a row.

(red color) - One or more rows with problem.


3.9 - Machine A or B Section Manual Power Off

This function is available only for the combined machines configuration, where, without leaving the tractor, the
operator can power off the machine A or the machine B manually in the display to perform the finishing in the area to
prevent undesired overlapping, etc.
To access this function, enter in the seed monitoring screen in ;
To power off the machine A, click and hold the button;

To power off the machine B, click and hold the button.

SYSTEM OPERATION
16
3060/70 - 3080/90 - 7080/90PD

NOTE:
To activate the section again, click on for the machine A and for the machine B.

When deactivating any section, the symbol will be displayed permanently on the work screen indication
that any of the sections is deactivated.
3.10 - Operational Clock
To view the Easytech system operational report, click on the work screen in .
In this screen, the following information is available
to the operator:

- All of worked area;


- Worked hours;
- Excess of speed in relation to the established for
the planting.

3.11 - Machine Under Transportation Warning

The warning serves to inform that the machine is in the transportation mode; however, the motors are powered
off, if you are planting and this warning is displayed, stop the planting and check the lifting sensor.

4 - SYSTEM CONFIGURATION

To start the Easytech system configuration, click on Menu in the home screen and then clique on Adjust

SYSTEM CONFIGURATION
17
Easytech - planting

AVAILABLE TO
}
}
THE OPERATOR

AVAILABLE ONLY FOR


AUTHORIZED TECHNICIANS

ATTENTION:
Only The basic and necessary configurations are accessible to the Easytech system user. The other
configurations are protected by passwords so that the equipment misuse does not occur. Only authorized and
properly trained and qualified Technicians can have access to the respective changes.
4.1 - Test Mode - RPM off Motors

The motors test mode serves to analyze if the hydraulic motors operation and rotation sensors (encoder) are
operating correctly with the machine stopped (static tests).

That test is also important to analyze if the tractor flow is being enough to command the motors.

To start the test, just select the motor you intent to operate and change the “working mode” state to “tests
mode” (the tractor hydraulic system must be powered on in working rotation).
ATTENTION:
When selecting the motor you intend to operate, make sure that there is nobody nearby to prevent
accidents.
As soon as the test is concluded, return to the “working mode”. It will be extremely important for the
implement good operation.

To analyze the encoders reading, go to , then click on Measurement and select the option Test
motors RPM.
In this measurement, you can observe problems such as lack of flow in the tractor hydraulics (practical RPM
does not reach the theoretical RPM) or problems with the encoder reading (practical RPM zero or oscillating with the
motor in fixed rotation).
In the display, both practical RPM and theoretical RPM are displayed, established by comparing the system
functionality.

PROBLEM OF
ENCODER
READING

PROBLEM OF
HYDRAULIC FLOW
(if not reach)

PROBLEM OF
ENCODER
READING

SYSTEM CONFIGURATION
18
3060/70 - 3080/90 - 7080/90PD

4.1.1 - Test mode - Seeds Monitor

After selecting the test mode option and the seeds monitor measurement, pass the cleaning brush inside the
seeds conductor, as soon as the equipment issues a sound signal and indicates a quantity of seeds in the display.
If it occurs, the sensor is operating correctly.

ATTENTION:
If the panel does not perform the measurement, check the seeds sensor connector or change it.
Seeds Monitor Test Mode: press the icon: MENU –

ADJUSTMENT - TEST MODE - SEEDS MONITOR


TEST MODE - SELECT TEST MODE
Test Mode Gauging: return to the work screen and

select the button: MENU – MEASUREMENTS – SE-


EDS MONITOR
When the checking is concluded, return to the menu,
test mode, seeds monitor and selection the option working
mode.

4.1.2 - Test Mode - Pneumatic Suspension

Checking the pneumatic system, observe if the value


of the pressure sensor icon is equal to the suspension pressu-
re icon.
Pneumatic Suspension Test Mode: press the icon:

MENU – ADJUSTMENT - TEST MODE - PNEUMA-


TIC SUSPENSION TEST MODE - SELECT TEST MODE
Test Mode Gauging: return to the work screen

and select the button: MENU – MEASUREMENTS –


PNEUMATIC SUSP TECHNICAL MEASUREMENTS
When the checking is concluded, return to the
menu, test mode, pneumatic suspension and select the option
working mode.

SYSTEM CONFIGURATION
19
Easytech - planting

4.2 - Planter Adjustment

To enter in the planter adjustment icon in the main screen, press the adjustment menu icon , then
“Adjust planter”.

In the option “Adjust planter”, we have:


- Collection recipient volume
This option changes the volume to be collected, the seed deposit level is used as reference.

- Number of custom holes


Create an new disc in the case it is not in the pre-configured drilling

- Low population error


Decreases the seed sensors reading sensitivity in the case the monitoring is displaying failures non-compliant
with the reality.

- High population error


Increases the error tolerance for the seed monitoring rate.

- Lifting sensor
Deactivates the lifting sensor inf it is damaged during the work.

- Power off the single machine


Enables or disables the powering off of the machines manual section.

- Power off seed sensors


This option disables a line sensor, if it is not making the reading or is damaged.

SYSTEM CONFIGURATION
20
3060/70 - 3080/90 - 7080/90PD

5 - OCCURRENCES, POSSIBLE CAUSES AND SOLUTIONS

Occurrences Possible Causes Note Solutions


Battery low voltage Change the battery / alternator
Monitor does not power on Power cables C1 in short-circuit / broken Use of multimeter Replace the power cable C1
Fuse 15A blown out Change the fuse 15A
Seed motor cable C4 broken Use of multimeter Replace the cable C4
Monitor indicates seed
circuit open / seed motor Seed motor cable connector improperly
Clean and check the
does not spin fitted / connectors pins insulated by dirty Visual identification
connector sockets and pins
or bent, misaligned
Manure motor cable C4 broken Use of multimeter Replace the cable C4
Monitor indicates manure
circuit open / manure Manure motor cable connector improperly
Clean and check the
motor does not spin fitted / connectors pins insulated by dirty Visual identification
connector sockets and pins
or bent, misaligned
Enable the motors
test mode for seed
and manure check
Application rates do not Adjust the tractor hydraulic
Tractor improper hydraulic flow the RPM’s theoretical
reach the theoretical ideal flow / use another tractor
x motor in the
measurement mode >
test motors RPM
See if the encoder is Change the Encoder / Tighten
Encoder with problems / Support loosen
making the reading the Support
application rate is very Encoder Cable broken (C4 Encoder) in the Motors RPM Replace the Cable
above the theoretical test mode / Use the
ideal / Encoder is not multimeter / Visual
performing the RPM Connectors improperly fitted / connectors assessment of Clean and check the
reading pins insulated by dirty or bent, misaligned connectors, observe connector sockets and pins
in the measurement
function
Monitor indicates Cable C2 or C3 broken Use of multimeter Replace the cable C2 or C3
controller with no Seed motor Cable connector Clean and check the
contact improperly fitted / connectors pins Visual identification connector sockets and
The manure and seed insulated by dirty or bent, misaligned pins
rate values are not
displayed
Note: Reason failure of Visual identification
Module blown out Provide the module change
communication between LED in the module
display and module
Wheel sensor far from the gear / Identificação visual Aproxime o sensor
Impurities (LED) / Observe da engrenagem / Tire
se no monitor impurezas / Reposicione
Cable connector (C6) improperly fitted está marcando Limpe e verifique encaixes
/ Connectors pins insulated by dirty velocidade e o dos conectores e pinos
or bent, misaligned ícone do trator está
ficando verde com Troque sensor de roda /
Sensor damaged / Cable (C6) broken velocidade cabo
The motors do not run Visual identification Approach the sensor /
with the machine in (LED) / check in reposition
movement Lifting sensor far from the drive the home screen Clean and check the
if the sensor is connector sockets and
Cable connector (C6) improperly fitted being activated at pins
/ Connectors pins insulated by dirty the moments in
or bent, misaligned which the machine
is being moved up Change the lifting sensor /
Sensor damaged / Cable (C6) broken and down or when cable
it is being driven
directly

OCCURRENCES
21
Easytech - planting

SEEDS MONITORING

Occurrences Possible Causes Note Solutions


Power cable (CM1 PWR) 12v of the Use of multimeter
seed module (broken or improperly / check for
fitted) connectors
Communication cable (CM1 Can) of improperly fitted
module (broken or improperly fitted) / connectors pins
Clean and check the
insulated by dirty
Seed monitoring is not connector sockets and
or bent
operating pins / Replace Sensors /
misaligned.
Power cable (CM2, CM3, CM4) of the Replace Cable
Observe in the
seed module (broken or improperly “measurement
fitted) function” the
seeds monitoring
behavior.
Power supply 12v is not supplying
Use of multimeter Change the Sensor
the sensor (Cable broken)
Some Seed Sensors are Dirty in the sensor Clean the Conductor
not operating Machine has 10
Machine configuration lines, however Configure
identifies 7

PNEUMATIC SPRINGS

Occurrences Possible Causes Note Solutions


Check if the Motor switch is ON Power on the switch
Check if the register is not closed Open the Registers (6 bar)
Pneumatic springs are
not inflating / valves do Check the Hoses and Springs for
Visual identification Troubleshoot leakages
not stop turning on and leakage
off Check if the pressurizing and
depressurizing valves position are Change position
totally horizontal
Cable Connector (CP2) improperly
fitted / connectors pins insulated by Change the cable
The do compressor dirty or bent, misaligned Use of multimeter in
motor does not run terminals
Check if 12v of voltage is supplying the
Battery / Alternator
motor

OCCURRENCES
22