26tsh110-Yellow Fluo4

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Test Report No.

BD/T(G)/17/036587
Dated 2018-01-02

Applicant : AMAZING FASHIONS LTD.


Road 07House -445 (2nd floor), DOHS,
Baridhara.Dhaka1206,Bangladesh

Attention : Mr. Kazi Tuhin,

Test Sample : Received on 2017-12-29 10:29 am OVERALL STATUS


Test Period : 2017-12-29 to 2018-01-02 Fail
Sample Description : Sample A:Four (04) Pieces Knitted T-Shirt in Color : Yellow Fluo-4

Fibre content : 60% Cotton 40% Polyester


Age limit : 3-9 Years
Supplier Item Code : 26TSH110
Test Program : Mandatory Pack
OVS Spa Supplier's Code : 44333
Department Code : 226
Manufacturer’s Name : AMAZING FASHIONS LTD.
Product category :M
OVS Spa Brand : OVS
Finishing or Special Claim : Non Peach
Name of Buyer/ Destination : OVS SpA
Note : The submitted Samples were not drawn by laboratory.

By accepting this document the customer hereby agrees and accepts the ‘Terms & Conditions’ and the relevant ‘Testing & Certification Regulations’ of TÜV
SÜD South Asia Pvt. Ltd. which are available at Company’s website at the link- http://www.tuv-sud.in/in-en/resource-centre/terms-and-conditions

Note: The test report is electronically generated. Hence original signature is not required.
Note : (1) The results relate only to the items tested, (2) The test report shall not be reproduced except in full without the written approval of the laboratory,

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 1 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

Result Summary / Conclusion

Test A
Colorfastness To Washing FAIL
Colorfastness To Water FAIL
Colorfastness To Rubbing FAIL
Colorfastness To Perspiration FAIL
Colorfastness To Saliva FAIL
Dimensional Stability To Washing PASS
Appearance After Washing PASS
Verification of Safety of Children Clothing PASS
Fiber Composition PASS
Flammability PASS
Presence Of Odour PASS

Test Result
Detection of Banned Amines PASS
Phthalates FAIL
Formaldehyde Content PASS
Total Cadmium Content PASS
Total Lead Content PASS
pH Value PASS

Authorised By

Moajjam Hossen Md. Harun-Or- Roshid


Report Reviewer Authorized Signatory
Please contact :
For any technical issues : Abdul Alim at Abdul.Alim@tuv-sud.com.bd
For any complaint : Md Kamruzzaman . at kamruz.zaman@tuv-sud.com.bd.

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 2 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

Test Result

Material List (As Identified By Laboratory)


Component no Component Description With Color Material Remark
Garment -
A1 Silver Foil print with Yellow Fluo-4 body Natural & Synthetic
fabric
A2 Black print with Yellow Fluo-4 body Natural & Synthetic
fabric
A3 Anthracite print with Yellow Fluo-4 neck Synthetic
tape
A4 Yellow Fluo-4 neck rib fabric Natural & Synthetic
A5 Fluo-4 body fabric Natural & Synthetic
A6 Silver Foil & Black print with Yellow Natural & Synthetic
Fluo-4 body fabric
Result Conclusion :

S.No. Test Composite Sampling Conclusion Remarks


(Material no.)
1 Detection of Banned Amines A1 + A2 PASS
2 Detection of Banned Amines A3 + A4 PASS
3 Phthalates A1 + A2 + A3 FAIL

4 Formaldehyde Content A6 PASS


5 Total Cadmium Content A1 + A2 + A3 PASS
6 Total Lead Content A1 + A2 + A3 PASS
7 pH Value A5 PASS

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 3 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

1.0 Colorfastness To Washing


ISO 105 C06 : 2010, A2S Single Test, 30 Minutes Mechanical Wash At 40ºC. In 0.4% ECE (B) Reference Detergent And 0.1% Sodium
Perborate Solution With 10 Steel Balls
Results Client Specs

Sample A Color Change . 4-5 4


Color Staining Acetate 3 4-5
Color Staining Cotton 4-5 4-5
Color Staining Nylon 2-3 4-5
Color Staining Polyester 4 4-5
Color Staining Acrylic 4-5 4-5
Color Staining Wool 4-5 4-5
Self Staining 4-5 4-5
Note:
Tested On Body + Print + Neck Tape

2.0 Colorfastness To Water


ISO 105-E01:2013/GB/T 5713 : 2013,

Results Client Specs

Sample A Color Change . 4-5 4


Color Staining Cotton 3-4 4-5
Color Staining Polyester 3-4 4-5
Self Staining 4-5 4-5
Note:
Tested On Body + Print
Remark: From Body

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 4 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

3.0 Colorfastness To Rubbing


ISO 105 X12: 2016 / GB/T 3920 : 2008,

Results Client Specs

Sample A Color Staining Dry 4 3-4


Color Staining Wet 2-3 3

Note:
Tested On Body + Print

4.0 Colorfastness To Perspiration


ISO 105-E04-2013, GB/T 3922 : 2013,

Acidic Alkaline Client Specs

Sample A Color Change . 4-5 4-5 4


Color Staining Cotton 3-4 3-4 4-5
Color Staining Polyester 3-4 3-4 4-5
Self Staining 4-5 4-5 4-5
Note:
Tested On Body + Print
Remark: From Body

5.0 Colorfastness To Saliva


GB/T 18886 : 2002,

Results Client Specs

Sample A Color Change . 4-5 4


Color Staining Cotton 3-4 4-5
Color Staining Polyester 3-4 4-5
Self Staining Self Staining 4-5 4-5
Note:
Tested On Body + Print
Remark: From Body

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 5 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

6.0 Dimensional Stability To Washing


ISO 6330 : 2000(E)+A1 : 2009 /ISO 5077 : 2007 / ISO 3759 : 2011, Wascator-Front Loading Horizontal Rotating Drum Type, Test Program
No. 5A, At 40°C with 2 kg Load, In 0.077% ECE (A) Reference Detergent, 0.003% Bleaching Activator (TAED) And 0.02% Sodium
Perborate Solution, Followed By Flat Dry
Original (cm) After 1st Wash Dimensional Client Specs
(cm) change (%)

Sample A Neck Width 18.7 18.6 -0.5 -4 to 2


Arm Hole Width 15.4 15.3 -0.6 -4 to 2
Chest Width 32.0 31.5 -1.6 -4 to 2
Shoulder 27.0 26.9 -0.4 -4 to 2
Bottom Width 30.7 30.6 -0.3 -4 to 2
Center Back Length 42.8 42.6 -0.5 -4 to 2
Sleeve Length 12.8 12.7 -0.8 -4 to 2
Side Seam 29.4 29.3 -0.3 -4 to 2
After 3rd Wash Dimensional Client Specs
(cm) change. (%)

Sample A Neck Width 18.6 -0.5 -4 to 2


Arm Hole Width 15.3 -0.6 -4 to 2
Chest Width 31.3 -2.2 -4 to 2
Shoulder 26.8 -0.7 -4 to 2
Bottom Width 30.5 -0.7 -4 to 2
Center Back Length 42.5 -0.7 -4 to 2
Sleeve Length 12.7 -0.8 -4 to 2
Side Seam 29.2 -0.7 -4 to 2

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 6 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

7.0 Appearance After Washing


LAB_P_ITP_13, Washing And Drying Procedure Same As Dimensional Stability To Washing

After 1st Wash Client Specs

Sample A Color Change Washed Sample 4-5 No Noticeable Change


Self Staining Self Staining 4-5

OBSERVATION

- Very Slight Colour Change Was Observed On The Washed Sample.

- No Visual Seam Opening Was Observed.

- No Visual Self/Cross Staining Was Observed.

- No Cracking/ Peeling Off Of Print Was Observed.

- No Removal Of Print Was Observed.

- No Fuzziness Was Observed.

- No Pilling Was Observed.

- No Spirality Was Observed.

The General Appearance Of The Washed Sample Is Found To Be Satisfactory.

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 7 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

8.0 Appearance After Washing


LAB_P_ITP_13,

After 3rd Wash Client Specs

Sample A Color Change Print Area 4-5 No Noticeable Change


Color Change Other Portion 4
Self Staining Self Staining 4-5
OBSERVATION

- Very Slight Colour Change Was Observed On The Print Area.

- Slight Colour Change Was Observed On The Other Portion

- No Visual Seam Opening Was Observed.

- No Visual Self/Cross Staining Was Observed.

- No Cracking/ Peeling Off Of Print Was Observed.

- Slight Removal Of Print Was Observed.

- Slight Fuzziness Was Observed.

- No Pilling Was Observed.

- No Spirality Was Observed.

The General Appearance Of The Washed Sample Is Found To Be Satisfactory.

9.0 Verification of Safety of Children Clothing


EN 14682:2014/GB/T 22702/GB/T 22705:2008,

Result Client Specs

Sample A Verification of Safety - Not Relevant (Pass) .

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 8 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

10.0 Fiber Composition


ISO 1833 -2006/GB/T 2910,GB/T/2911,

Results ISO Results GB Client Specs

Sample A Fiber Identification . Cotton + Polyester Cotton + Polyester .


Fiber Composition Cotton 59.1% 59.3% 60% Cotton
Fiber Composition Polyester 40.9% 40.7% 40% Polyester
ISO-Remark: Based On Moisture Regain Weight
Moisture Regain Of Cotton 8.5% Polyester 1.5%

GB-Remark: Based On Moisture Regain Weight


Moisture Regain Of Cotton 8.0% Polyester 0.4%

Note : Excluding Of Neck Rib Which Containing Cotton + Polyester , Elastane

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 9 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

11.0 Detection of Banned Amines


Based on EN 14362-1 : 2017 / GB/T 17592-2011, Equipment Used: GC-MS/UPLC-DAD

Analysis CAS No. A1 + A2 A3 + A4 Client Specs

Benzidine 92-87-5 ND ND 20 ppm


o-aminoazotoluene 97-56-3 ND ND
3,3'-dichlorobenzidine 3,3'-dichlorobip 91-94-1 ND ND
o-toluidine 2-aminotoluène 95-53-4 ND ND
2,6-xylidine 87-62-7 ND ND
4-aminobiphenyl 92-67-1 ND ND
4-chloro-o-toluidine 95-69-2 ND ND
2-naphthylamine 91-59-8 ND ND
2-amino-4-nitrotoluene 99-55-8 ND ND
p-chloroaniline 106-47-8 ND ND
2,4-diaminoanisole 615-05-4 ND ND
4-4'-diaminodiphenylmethane 101-77-9 ND ND
3,3'-dimethoxybenzidine 119-90-4 ND ND
3,3'-dimethylbenzidine 119-93-7 ND ND
3,3'-dimethyl-4,4'diaminodiphenylmeth 838-88-0 ND ND
p-cresidine 120-71-8 ND ND
4,4'-methylene-bis-(2-chloroaniline) 101-14-4 ND ND
4,4'-oxydianiline 101-80-4 ND ND
4,4'-thiodianiline 139-65-1 ND ND
2,4-toluylendiamine 95-80-7 ND ND
2,4,5-trymethylaniline 137-17-7 ND ND
2-methoxyaniline 90-04-0 ND ND
p-aminoazobenzene 60-09-3 ND ND
2,4-xylidine 95-68-1 ND ND
Remark: ND = Not Detected
Limit of Quantification = 5 ppm (mg/kg)
ppm = parts per million = mg/kg

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 10 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

12.0 Phthalates
EN ISO 14389:2014 GB/T 20388:2006, Equipment Used: GC-MS

Analytes CAS No. A1 + A2 + A3 Client Specs

Di-iso decyl Phthalate(DIDP) 26761-40-0 ND Sum <0.1 %

Di-iso nonyl Phthalate(DINP) 28553-12-0 ND

Dipentyl phthalate (DPP) 131-18-0 ND

n-pentyl-isopentyl phthalate (nPiPP) 776297-69-9 ND

Dimethyl Phthalate (DMP) 131-11-3 ND

Diisopentylphthalate (DIPP) 605-50-5 ND

Di-butyl Phthalate(DBP) 84-74-2 ND

Bis-(2-Ethyl Hexyl )Phthalate (DEHP) 117-81-7 0.068%

Benzyl Butyl Phthalate (BBP) 85-68-7 ND

Di-n-octyl Phthalate(DNOP) 117-84-0 ND

Di-iso-butyl Phthalate(DIBP) 84-69-5 ND

Di-n-hexyl Phthalate(DnHP) 84-75-3 ND

Bis-(2-methoxyethyl )Phthalate (DMEP) 117-82-8 ND

1,2 benzene dicarboxylic acid, di –C7-11 68515-42-4 ND


branched and linear alkyl esters
(DHNUP)
1,2 benzene dicarboxylic acid, di –C6-8 71888-89-6 ND
branched alkyl esters C7 rich -(DIHP)
Di Ethyl Phthalates 84-66-2 ND

1,2-benzenedicarboxylic acid, 84777-06-0 ND


dipentylester, branched and linear
1,2-Benzenedicarboxylic acid, dihexyl 68515-50-4 ND
ester, branched and linear
Sum of All - 0.068%
Remark: ND= Not Detected
Limit of Quantification = 50 mg/kg or 0.005% (Individual)
1% = 10,000 mg/kg (ppm)

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 11 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

13.0 Formaldehyde Content


ISO 14184-1 : 2011/ GB/T 2912.1, Equipment used: UV-VIS Spectrophotometer

Analytes CAS No. A6 Client Specs

Formaldehyde 50-00-0 ND 20 ppm

ND = Not Detected
Limit of Quantification = 16 ppm(mg/kg)
ppm = parts per million = mg/kg

14.0 Flammability
GB/T 14644:2014,

Results Client Specs

Sample A . Class 1 Class 1

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 12 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

X PLAIN SURFACE RAISED SURFACE

Original After Refurbishing #

TIME BURN TIME BURN


(SECONDS) CHARACTERISTICS (SECONDS) CHARACTERISTICS
1 DNI 1 DNI

2 DNI 2 DNI

3 DNI 3 DNI

4 DNI 4 DNI

5 DNI 5 DNI

AVERAGE* AVERAGE*

6 6

7 7

8 8

9 9

10 10

AVERAGE** AVERAGE**

CLASSIFICATION CLASS 1

#Refurbishing #Class 1 or 2 sample shall be washed once by stirring normally at 40°c with type A washer according to those specified in GB/T
8629. Sample shall be flattened and dried by airing. If required dry cleaning shall be performed according to the requirements of GB/T
19981.2-2005
EXPLANATION OF FLAMMABILITY RESULTS.
For Plain Surface Fabrics
DNI: DID NOT IGNITE BB-BASE BURN IBE: IGNITED BUT EXTINGUISHED
_._sec: ACTUAL BURN TIME MEASURED AND RECORDED BY THE TIMING DEVICE.

For Raised Surface Fabrics


SF uc - SURFACE FLASH, UNDER THE STOP THREAD, BUT DOES NOT BREAK THE STOP THREAD
SF pw - SURFACE FLASH, PART WAY, NO TIME SHOWN BECAUSE THE SURFACE FLASH DID NOT REACH THE STOP THREAD.
SF poi - SURFACE FLASH, AT THE POINT OF IMPINGEMENT ONLY
_._ sec. - ACTUAL BURN TIME MEASURED BY THE TIMING DEVICE IN 0.0 SECONDS
_._SF only - TIME IN SECONDS, SURFACE FLASH ONLY.

_._SFBB - TIME IN SECONDS, SURFACE FLASH BASE BURN STARTING AT PLACES OTHER THAN THE POINT OF IMPINGEMENT
AS A RESULT OF SURFACE FLASH.

_._SFBB poi - TIME IN SECONDS, SURFACE FLASH, BASE BURN STARTING AT THE POINT OF IMPINGEMENT
_._SFBB poi - TIME IN SECONDS, SURFACE FLASH, BASE BURN POSSIBLY STARTING AT THE POINT OF IMPINGEMENT(*UNABLE TO
MAKE ABSOLUTE DETERMINATION AS TO SOURCE OF BASE BURNS.)

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 13 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

15.0 Total Cadmium Content


Based on GB/T 30157:2013, Equipment Used: ICP-OES

Analytes CAS No. A1 + A2 + A3 Client Specs

Cadmium ND 100 ppm

Remark: ND = Not Detected


Limit of Quantification = 3 ppm(mg/kg)
ppm = parts per million = mg/kg

16.0 Total Lead Content


GB/T 30157: 2013, Equipment used: ICP-OES

A1 + A2 + A3 Client Specs

Lead ND 90 ppm

Remark: ND = Not Detected


Limit of Quantification = 3 ppm(mg/kg)
ppm = parts per million = mg/kg

17.0 pH Value
ISO 3071-2005/ GB/T 7573-2009, Equipments used : pH METER

A5 Client Specs

Result pH Value 7.0 4 to 7.5

Remark: Solution Used 0.1(M) KCl


Temperature: 24.1 °C

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 14 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

18.0 Presence Of Odour


In House Test Method/GB 18401 Section 6.7,

Results Client Specs

Sample A Observation 4-5 4

Note:(Intemediate Grades Are Allowed)


5. Odour Less
4. Weak Odour
3. Tolerable Odour
2. Annoying Odour
1. Intolerable Odour.

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 15 of 16
ControlNo:25601240.291217.092
Test Report No.BD/T(G)/17/036587
Dated 2018-01-02

- END OF TEST REPORT-

Laboratory: Regd. Office:


TÜV SÜD Bangladesh Pvt. Ltd. Phone :+ 88 02 58954115, 58954120 TÜV SÜD Bangladesh Pvt. Ltd., Level
Update Tower, Level 7 & 8, Fax :+ 88 02 58956724 7&8, Update Towers, No.1, Shahjalal
01 Shahjalal avenue, Sector 6, E-Mail :Nazrul.Islam@tuv-sud.com.bd Avenue, Uttara Model Town, Sector 6,
Uttara Model town,.Dhaka1230 Url : www.tuv-sud.in/softlines Dhaka 1230 Page 16 of 16
ControlNo:25601240.291217.092

You might also like