Final Joint Inspection Report of LHB Eog Accoaches Coach Particulars

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 7

FINAL JOINT INSPECTION REPORT OF LHB EOG ACCOACHES

Coach Particulars
S.No. Particulars of the coach Details
1. Coach No.
2. Depot / Railways
3. Workshop name
4. Coach booked on
5. Coach booked for SS-I/ SS-II
6. Date of Inspection
7. Return Date

Final Checking

S.No. Description of Checks Observations / Remark


1.0 Roof Mounted AC Package Unit (RMPU)
1.1 Compressor
Make of Compressor
PP Side 1. 2.
NPP Side 1. 2.
Condition of anti-vibration mountings
PP Side 1. OK / Not OK 2. OK / Not OK
NPP Side 1. OK /Not OK 2. OK /Not OK
Condition of terminal boxes
PP Side 1. OK / Not OK 2. OK / Not OK
NPP Side 1. OK /Not OK 2. OK /Not OK
Any abnormal noise during run
PP Side 1. 2.
NPP Side 1. 2.
1.2 Condenser Motors
Make of condenser motor
PP Side 1. 2.
NPP Side 1. 2.
Condition of terminal boxes
PP Side 1. OK / Not OK 2. OK / Not OK
NPP Side 1. OK /Not OK 2. OK /Not OK
Abnormal noise noticed during run
PP Side 1. 2.
NPP Side 1. 2.

S.No. Description of Checks Observations / Remark


1.3 Evaporator Motor
Make of evaporator motor
PP Side 1. 2.
NPP Side 1. 2.
Condition of terminal boxes
PP Side 1. OK / Not OK 2. OK / Not OK
NPP Side 1. OK /Not OK 2. OK /Not OK
Any abnormal noise noticed during run
PP Side 1. 2.
NPP Side 1. 2.
Condition of drip tray
PP Side OK /Not OK
NPP Side OK /Not OK
1.4 Servo Motor
Make of Servo motors
PP Side 1. 2.
NPP Side 1. 2.
Condition of Servo Motors
PP Side 1. OK / Not OK 2. OK / Not OK
NPP Side 1. OK /Not OK 2. OK /Not OK
1.5 Heating Elements
Make of Heating Elements
PP Side 1.
NPP Side 1.
Condition of Heating Elements PP
Side 1. OK / Not OK
NPP Side 1. OK /Not OK
1.6 Filters
Make of Filters
Return air
PP Side 1. 2.
NPP Side 1. 2.
Fresh air
PP Side 1. 2.
NPP Side 1. 2.
Condition of Filters
Fresh air 1. OK / Not OK 2. OK / Not OK
Return air 1. OK /Not OK 2. OK /Not OK

S.No. Description of Checks Observations / Remark


1.7 Protection Devices
Condition of HP output
PP Side 1. OK / Not OK 2. OK / Not OK
NPP Side 1. OK /Not OK 2. OK /Not OK
Condition of LP cutouts
PP Side 1. OK / Not OK 2. OK / Not OK
NPP Side 1. OK /Not OK 2. OK /Not OK
Condition of control pressure switch
PP Side OK /Not OK
NPP Side OK /Not OK
Condition of ESTI fusible link
PP Side OK / Not OK
NPP Side OK / Not OK
Condition of OHP
PP Side OK / Not OK
NPP Side OK / Not OK
Condition of temperature sensors
PP Side OK / Not OK
NPP Side OK / Not OK
Condition of humidity sensors
PP Side OK / Not OK
NPP Side OK / Not OK
1.8 Refrigerant Pipe Line
Condition of Clamping of pipe line
PP Side OK / Not OK
NPP Side OK / Not OK
2.0 Switch Board Cabinet
Condition of rotary switches OK / Not OK
Condition of MCBs for
Light OK / Not OK
Fan circuit OK / Not OK
Other MCBs OK / Not OK
Condition of terminals OK / Not OK
Condition of contractors OK / Not OK
Condition of relays OK / Not OK
Condition of meters
Ammeters OK / Not OK
Voltmeters OK / Not OK
Pressure Gauges OK / Not OK
S.No. Description of Checks Observations / Remark
Condition of cable OK / Not OK

Condition of clamping of cables OK / Not OK


Condition of conduits OK / Not OK
3.0 Compartment

Condition of exhaust fans OK / Not OK


Condition of lights OK / Not OK
Condition of berth lights OK / Not OK
Condition of switches OK / Not OK
Condition of indication lights OK / Not OK
4.0 Micro Processor Controller

Micro processor controller OK / Not OK


Condition of connections OK / Not OK
Condition of LEDs OK / Not OK
5.0 Battery

Make
Lug date
Battery box suspension arrangement OK / Not OK
Battery cells ventilation OK / Not OK
Battery box inside anti corrosion painting OK /Not OK
Condition of battery lugs OK / Not OK
Condition of cell container OK / Not OK
Condition of battery fuse & fuse box OK / Not OK
Earth leakage of battery leakage / Not leakage
Battery no load voltage in volts _______volts
6.0 Battery Charger

Make of battery charger


Condition of battery charger OK / Not OK
Condition of battery charger mounting OK / Not OK
arrangement
7.0 Pantry Equipments

Condition of Deep freezer OK / Not OK


Condition of bottle cooler OK / Not OK
Condition of water boiler OK / Not OK
Condition of hot case OK / Not OK

8.0 EOG Coupler


Condition of coupler
PP Side 1. OK / Not OK 2. OK / Not OK
NPP Side 1. OK /Not OK 2. OK /Not OK
Condition of coupler pins
PP Side 1. OK / Not OK 2. OK / Not OK
NPP Side 1. OK /Not OK 2. OK /Not OK
Condition of locking arrangement
PP Side 1. OK / Not OK 2. OK / Not OK
NPP Side 1. OK /Not OK 2. OK /Not OK
9.0 60 KVA Transformer
Condition of mounting arrangement OK /Not OK
Condition of terminals OK /Not OK
10.0 Lighting Transformer
Condition of mounting arrangement OK /Not OK
Condition of terminals OK /Not OK
11.0 Other Equipments
Condition of WRA 1. OK /Not OK 2. OK /Not OK
Condition of micro controller for WRA OK /Not OK
Condition of pre cooling socket 1. OK /Not OK 2. OK /Not OK
12.0 Earthing of all Equipments Provided / Not Provided
13.0 Pantry Equipments
Hot Case OK / NOT OK
Deep freezer OK / NOT OK
Water boiler OK / NOT OK
Chimney 1,2,3 OK / NOT OK
Burner 1,2,3 OK /Not OK
Insect Killer OK /Not OK
Fridge OK /Not OK
Working of call station OK /Not OK
Equipments Replaced

Name of Equipment Make Rating/ Capacity Serial No.


S.No

REMARKS IF ANY
Base Depot POH Shop
Name & Designation: - Name & Designation: -

You might also like