Site Preparation
B006-6641-A000
1208
EMC COMPLIANCE
Federal Communications Commission (FCC) Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user
will be required to correct the interference at his own expense.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites
dans le Réglement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
This is a Class A product, in a domestic/residential environment this product may cause radio interference in which case the user may be required to
take adequate measures.
Information to User
This equipment must be installed and used in strict accordance with the manufacturer’s instructions. However, there is no guarantee that interference
to radio communications will not occur in a particular commercial installation. If this equipment does cause interference, which can be determined by
turning the equipment off and on, the user is encouraged to consult an NCR service representative immediately.
CAUTION
NCR Corporation is not responsible for any radio or television interference caused by unauthorised modifications of this
equipment or the substitution or attachment of connecting cables and equipment other than those specified by NCR.
Such unauthorized modifications, substitutions, or attachments may void the user’s authority to operate the equipment.
The correction of interference caused by such unauthorized modifications, substitutions, or attachments will be the
responsibility of the user.
The ATM complies with the following Electromagnetic Compatibility (EMC) directives and standards for IT equipment:
• 2004/108/EC ‘EMC Directive’
• 93/68/EEC ‘CE Marking Directive’.
For further information, refer to the Electromagnetic Compatibility (EMC) and Safety section.
NOTICE
This is a contractual document. It contains important warnings and confers important legal rights and obligations. You are advised to read it carefully.
It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with all specifications and requirements
of NCR and all applicable national, state, or local codes, regulations and laws.
NCR and NCR SelfServ are trademarks of NCR Corporation. Other product names mentioned in this publication may be trademarks or registered
trademarks of their respective companies and are hereby acknowledged.
It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available. NCR,
therefore, reserves the right to change specifications without prior notice.
All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of
equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office for information that is applicable
and current.
© 2008
By NCR Corporation, Dayton, Ohio U.S.A.
http://www.ncr.com
All Rights Reserved
Table of Contents
INTRODUCTION ...............................................................................................................1
How to Use This Site Preparation Bookset ....................................................................2
Purpose and Audience ....................................................................................................2
Site Compliance..............................................................................................................2
Customer Responsibilities ..............................................................................................3
Product Identification .....................................................................................................4
PACKAGE DIMENSIONS.................................................................................................5
Manoeuvring the ATM Into Position..............................................................................6
Standard Sleeve..........................................................................................................6
ATM DIMENSIONS...........................................................................................................8
Standard Sleeve Without Collar .....................................................................................9
UL Security Enclosure ...............................................................................................9
CEN Security Enclosure ..........................................................................................10
Short Sleeve Without Collar .........................................................................................11
UL Security Enclosure .............................................................................................11
CEN Security Enclosure ..........................................................................................12
Collar Dimensions ........................................................................................................13
Standard Collar ........................................................................................................13
Advert Collar............................................................................................................14
B006-6641-B000 i
The optimum distance between the security enclosures of two ATMs, installed side by side,
is 500 mm (19.7 in.)23
Minimum Clearances ....................................................................................................24
Standard Sleeve........................................................................................................24
Short Sleeve .............................................................................................................25
Minimum Distance Between Two Installations.......................................................26
Exterior Wall Clearances ..............................................................................................27
Standard Collar ........................................................................................................27
Advert Collar............................................................................................................27
VIDEO CAMERA.............................................................................................................42
Ambient Lighting..........................................................................................................42
Internal Space Constraint for Fitting a Third-Party Video Camera..............................43
ii B006-6641-B000
Standard Collar With Advert Light ..............................................................................46
Opaque Window ......................................................................................................46
Clear Window ..........................................................................................................47
Entry/Exit Slot Decal ....................................................................................................48
B006-6641-B000 iii
iv B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
Table of Contents
INTRODUCTION
The NCR SelfServ 26 Automated Teller Machine (ATM) may be installed through any
suitable exterior wall or vestibule location.
B006-6641-B000 1
NCR SelfServ 26 ATM Site Preparation
Site Compliance
This bookset contains the information necessary for the preparation of a site conforming to
NCR specifications. It is very important that the site complies with the requirements
specified in this bookset, because, once the equipment has been installed, deficiencies in
site preparation or the problems caused by these deficiencies are much more difficult to
detect and correct. Further, failure to comply with these requirements or to take proper
steps to protect equipment against risks identified in this bookset may cause serious
damage to the equipment and to the customer’s business.
In addition to the need to comply with the requirements specified, electrical wiring and
mechanical systems must also comply with all relevant codes, laws and regulations.
It is important that the site be prepared by a customer or his agent who is fully conversant
with the special requirements of electronic equipment. The responsibility for ensuring that
the site is prepared in compliance with this bookset remains with the customer.
For information and guidance purposes only, a list is provided, in general terms, of those
matters for which the customer is responsible. This list is not intended to be
comprehensive, and in no way modifies, alters, or limits the responsibility of the customer
for all aspects of adequate site preparation.
2 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
NCR staff will be available to answer questions relating to the contents of this bookset but,
except where:
a the customer has been notified that a full or partial consultancy service is available
and/or that NCR will be willing to undertake a preliminary or final site survey and
b the customer shall have entered into a formal contract with NCR for provision of the
same
no comment, suggestion or advice offered or not offered about preparation of the site nor
any inspection of the site whether before or after preparation is to be taken as approval of
the location of the site and equipment or of its preparation and NCR will not be liable in
respect of any comment, suggestion or advice given by its staff or in respect of any failure
to give advice.
Finally, only the customer can know the full extent of damage which may be caused to his
business by reason of failure of the equipment which is to be installed. For this reason it is
the customer’s responsibility to ascertain the extent of any such possible damage to his
existing or planned business, and to effect, full insurance in respect of it.
Customer Responsibilities
The customer must do or provide the following:
z When required by NCR, provide the NCR customer service representative with
appropriate drawings that indicate:
z Location of the equipment
z Site wiring (power and signal, paths and lengths)
z Location of other equipment capable of generating electrical noise,
electromagnetic interference, heat, etc.
z Make building alterations necessary to meet wiring and other site requirements.
z Provide and install all communications cables, wall jacks, special connectors, and
associated hardware.
z Provide and install necessary power distribution boxes, conduits, grounds, lightning
protection, and associated hardware.
z Make sure all applicable codes, regulations and laws (including, but not limited to,
electrical, building, safety, and health) are met.
z Provide and install auxiliary power or other equipment as required.
z Provide storage or service areas as required.
z Make sure the environmental requirements of the system/unit are met.
z Provide floor coverings and environmental systems that limit or control static
electricity build-up and discharge.
z Install the product at a height which meets the accessibility regulations of the relevant
country.
B006-6641-B000 3
NCR SelfServ 26 ATM Site Preparation
Product Identification
The product is identified by a class type number, SelfServ 26, and a 4 digit model number,
which is printed on a label fixed inside the top cabinet of the ATM. The serial number is
unique to each ATM. The tracer number is used to identify where the ATM was built.
Please quote all of the serial and tracer numbers, including the prefix, when making
reference to the ATM.
4 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
PACKAGE DIMENSIONS
The dimensions of a packaged and unpackaged ATM are shown in the following
illustration.
805 mm
1420 mm (31.7 in.)
(55.9 in.)
1827 mm
(71.9 in.)
1405 mm
801 mm (55.3 in.)
(31.5 in.)
B006-6641-B000 5
NCR SelfServ 26 ATM Site Preparation
Note 1: The dimensions assume the ATM is being moved using equipment that does not
extend beyond the ATM or packaging.
Note 2: A surrounding clearance of 6 mm (0.24 in.) has been allowed in the figures.
Standard Sleeve
A B
6 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
Short Sleeve
A B
B006-6641-B000 7
NCR SelfServ 26 ATM Site Preparation
ATM DIMENSIONS
The following illustrations show dimensions for ATMs configured with CEN Grade L,
CEN Grade I, CEN Grade III, CEN Grade IV Spanish Certified and UL 291 Level 1
security enclosures.
Note: Cables enter the ATM through the hole in the base of the ATM security enclosure.
Refer to page 37 for the location of the hole.
8 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
UL Security Enclosure
The illustration below shows the dimensions for a standard sleeve ATM configured with a
UL security enclosure. It shows the sleeve before a collar has been fitted.
742 mm
(29.21 in.)
371 mm
(14.61 in.)
23 mm 424 mm 23 mm
(0.90 in.) (16.69 in.) (0.90 in.)
1211 mm
(47.68 in.)
473 mm 803 mm
(18.62 in.) (31.61 in.)
1489 mm
(58.62 in.)
372 mm
(14.65 in.)
836 mm
713 mm (32.91 in.)
(28.07 in.)
837 mm
(32.95 in.)
B006-6641-B000 9
NCR SelfServ 26 ATM Site Preparation
742 mm
(29.21 in.)
371 mm
(14.61 in.)
23 mm 424 mm 23 mm
(0.90 in.) (16.69 in.) (0.90 in.)
A
473 mm 803 mm
(18.62 in.) (31.61 in.)
1498 mm
(58.98 in.)
372 mm
(14.65 in.)
845 mm
722 mm (33.27 in.)
(28.43 in.)
CEN L, CEN I CEN III, CEN IV CEN L, CEN I CEN III, CEN IV
1237 mm 1257 mm 863 mm 883 mm
A B
(48.7 in.) (49.49 in.) (33.98 in.) (34.76 in.)
10 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
UL Security Enclosure
The illustration below shows the dimensions for a short sleeve ATM configured with a UL
security enclosure. It shows the sleeve before a collar has been fitted.
742 mm
(29.21 in.)
258 mm
(10.16 in.)
23 mm 424 mm 23 mm
(0.90 in.) (16.69 in.) (0.90 in.)
1097 mm
(43.19 in.)
473 mm 803 mm
(18.62 in.) (31.61 in.)
1489 mm
(58.62 in.)
258 mm
(10.16 in.)
836 mm
713 mm (32.91 in.)
(28.07 in.)
837 mm
(32.95 in.)
B006-6641-B000 11
NCR SelfServ 26 ATM Site Preparation
742 mm
(29.21 in.)
258 mm
(10.16 in.)
23 mm 424 mm 23 mm
(0.90 in.) (16.69 in.) (0.90 in.)
473 mm 803 mm
(18.62 in.) (31.61 in.)
1498 mm
(58.98 in.)
258 mm
(10.16 in.)
845 mm
722 mm (33.27 in.)
(28.43 in.)
CEN L, CEN I CEN III, CEN IV CEN L, CEN I CEN III, CEN IV
1123 mm 1143 mm 863 mm 883 mm
A B
(44.21 in.) (45.00 in.) (33.98 in.) (34.76 in.)
12 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
Collar Dimensions
Standard Collar
The illustration below shows the dimensions for an ATM configured with a standard
collar.
548 mm 38 mm
(21.57 in.) (1.50 in.)
660 mm
(25.98 in.)
39 mm 39 mm
(1.54 in.) (1.54 in.)
B006-6641-B000 13
NCR SelfServ 26 ATM Site Preparation
Advert Collar
The illustration below shows the dimensions for an ATM configured with an advert collar.
548 mm 38 mm
(21.57 in.) (1.50 in.)
660 mm
(25.98 in.)
39 mm 39 mm
(1.54 in.) (1.54 in.)
14 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
Note: If a 12.1 inch display is fitted the FDKs and touchscreen are lowered. In this case
the highest operable point is lowered by 43 mm (1.70 in.). Other interface elements
remain at the same height.
Height Depth
(from base of ATM) (from front of
collar)
B006-6641-B000 15
NCR SelfServ 26 ATM Site Preparation
735 mm 764 mm 65 mm
E SS Cash Exit (28.94 in.) (30.08 in.) (2.56 in.)
853 mm 862 mm 67 mm
F Audio Jack Plug (33.58 in.) (33.94 in.) (2.64 in.)
front
A B C D E F G H I
16 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
38o
B006-6641-B000 17
NCR SelfServ 26 ATM Site Preparation
B
C
A D
Task Lighting
A minimum of 200 LUX is required for task lighting.
18 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
Wheelchair Clearance
The following illustration shows the clearance required for wheelchair approach and
turning circle.
1524 mm
(60.0 in.)
1524 mm
(60.0 in.)
B006-6641-B000 19
NCR SelfServ 26 ATM Site Preparation
Note: Installing the ATM in the minimum servicing areas may impact servicing
and/or upgrading times.
20 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
Optimum Clearances
Standard Sleeve
The illustration below shows the optimum clearance dimensions for an ATM configured
with a UL, or CEN, security enclosure and standard sleeve.
1470 mm
(57.9 in.)
1500 mm
(59.1 in.)
2315 mm
(91.1 in.)
330 mm
(13.0 in.)
750 mm
(29.5 in.)
B006-6641-B000 21
NCR SelfServ 26 ATM Site Preparation
Short Sleeve
The illustration below shows the optimum clearance dimensions for an ATM configured
with a UL, or CEN, security enclosure and short sleeve.
1470 mm
(57.9 in.)
1500 mm
(59.1 in.)
2328 mm
(91.7 in.)
203 mm
(8.0 in.)
750 mm
(29.5 in.)
22 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
The optimum distance between the security enclosures of two ATMs, installed side by side,
is 500 mm (19.7 in.)
2440 mm
(96.1 in.)
1500 mm
(59.1 in.)
750 mm
(29.5 in.)
A B C
Short Sleeve 2328 mm 203 mm 828 mm
(91.7 in.) (8.0 in.) (32.6 in.)
Standard Sleeve 2315 mm 330 mm 815 mm
(91.1 in.) (13.0 in.) (32.1 in.)
B006-6641-B000 23
NCR SelfServ 26 ATM Site Preparation
Minimum Clearances
The following illustrations show the minimum areas required for installing and servicing
the ATM.
Standard Sleeve
The illustration below shows the minimum clearance dimensions for an ATM configured
with a UL, or CEN, security enclosure with a standard sleeve.
1150 mm
(45.3 in.)
900 mm
(35.4 in.)
1715 mm 2045 mm
(67.5 in.) (80.5 in.)
380 mm
(15.0 in.) 470 mm 300 mm
(18.5 in.) (11.8 in.) 815 mm
(32.1 in.)
150 mm
(5.9 in.)
330 mm
(13.0 in.)
Note 1: This area is required for minimum service clearance. If this area is not available
please refer to “Important Notice to Users” on page 20 and consult your local service
representative.
24 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
Short Sleeve
The illustration below shows the minimum clearance dimensions for an ATM configured
with a UL, or CEN, security enclosure with a short sleeve.
1150 mm
(45.3 in.)
900 mm
(35.4 in.)
1728 mm 1931 mm
(68.0 in.) (76.0 in.)
380 mm
(15.0 in.) 470 mm 300 mm
(18.5 in.) (11.8 in.) 828 mm
(32.6 in.)
150 mm
(5.9 in.)
203 mm
(8.0 in.)
Note 1: This area is required for minimum service clearance. If this area is not available
please refer to “Important Notice to Users” on page 20 and consult your local service
representative.
B006-6641-B000 25
NCR SelfServ 26 ATM Site Preparation
2000 mm
(78.7 in.)
900 mm
(35.4 in.)
A B C
Short Sleeve 1728 mm 203 mm 828 mm
(68.0 in.) (42.32 in.) (32.6 in.)
Standard Sleeve 1715 mm 330 mm 815 mm
(67.5 in.) (64.13 in.) (32.1 in.)
Note: This area is required for minimum service clearance. If this area is not available
please refer to “Important Notice to Users” on page 20 and consult your local service
representative.
26 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
Standard Collar
10 mm
(0.39 in.)
45 mm
(1.77 in.)
30 mm 30 mm
(1.18 in.) (1.18 in.)
Advert Collar
10 mm
(0.39 in.)
45 mm
(1.77 in.)
30 mm 30 mm
(1.18 in.) (1.18 in.)
B006-6641-B000 27
NCR SelfServ 26 ATM Site Preparation
In addition to the side panels the monitor and bezel can also be unlatched and removed to
allow access behind the facia from the front.
28 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
COLLAR TOLERANCE
The wall and floor need to be smooth and even as the collar has a tolerance of +/- 4 mm
(0.2 in. (+/- 0.5°)) at the top and bottom, with 0 mm (0.0 in. (0°)) at its centre. This is
shown in the following illustration.
Note: The collar cannot accommodate large dips or depressions in the wall.
+/- 4 mm
(0.2 in.)
0.0 mm
(0.0 in.)
+/- 4 mm
(0.2 in.)
B006-6641-B000 29
NCR SelfServ 26 ATM Site Preparation
INSTALLATION CATEGORIES
There are two categories of physical installation of the ATM:
z Installation at NCR optimum height.
z Installation at lowered height.
Lowered Heights
The following installation heights have been designed to meet the regulations listed below
and therefore meet the requirements of both able-bodied and disabled people.
Note: To comply with ADA Accessibility Guidelines (ADAAG), July 2004, refer only to
the forward approach.
30 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
B006-6641-B000 31
NCR SelfServ 26 ATM Site Preparation
443 mm
(17.44 in.)
793 mm
(31.22 in.)
A B
Installation Height
32 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
Note 1: The actual height of the plinth depends upon the difference in height between the
sidewalk and the interior floor. If, as the illustration shows, there is no difference, then the
plinth must have the height that is specified in the table above.
Note 2: The standard sleeve ATM can be installed through a wall that is a maximum of
330 mm (13.0 in.) thick. The short sleeve ATM can be installed through a wall that is a
maximum of 203 mm (8.0 in.) thick.
Note 3: For ease of installation; NCR recommends installation through a larger hole in
the wall.
B006-6641-B000 33
NCR SelfServ 26 ATM Site Preparation
443 mm
(17.44 in.)
793 mm
(31.22 in.)
924 mm
(36.38 in.)
A
Note 1: The actual height of the plinth depends upon the difference in height between the
sidewalk and the interior floor. If, as the illustration shows, there is no difference, then the
plinth must be the height that is specified in the table above.
Note 2: The standard sleeve ATM can be installed through a wall that is a maximum of
330 mm (13.0 in.) thick. The short sleeve ATM can be installed through a wall that is a
maximum of 203 mm (8.0 in.) thick.
Note 3: For ease of installation; NCR recommends installation through a larger hole in
the wall.
34 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
B006-6641-B000 35
NCR SelfServ 26 ATM Site Preparation
Floor Covering
An antistatic floor covering should be used and must be of a type that will not generate
dust or fluff. The surface on which the ATM is to be sited should be level and even. In
locations where the floor may be uneven, it is recommended that a steel plate is used under
the ATM.
Floor Loading
The ATM must be installed on a floor capable of supporting the maximum weight. Only
the maximum weight should be considered as additional options may be added after
installation.
36 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
BOLT HOLES
The following illustrations show a plan of the base of the ATM (viewed from above) and
its relationship with the exterior wall. The plan should be used for pre-drilling bolt holes
‘A’ and illustrates the design of the steel plate, if used. If a plinth is used it should be no
smaller than the base of the ATM and it must be constructed of a material, and in such a
way, that it is capable of supporting the weight of the ATM (see page 36).
The definition of a plinth is a platform on to which the ATM is bolted. This plinth enables
the ATM to be installed at the required height through the wall.
470 mm
(18.50 in.)
60 mm 270 mm 140 mm
(2.36 in.) (10.63 in.) (5.51 in.)
135 mm 254 mm
(5.31 in.) (10.00 in.)
A A
800 mm 247 mm
(31.50 in.) (9.72 in.)
428 mm
B
(16.85 in.)
175 mm 33 mm
(6.89 in.) (1.30 in.)
A A
118 mm
(4.65 in.)
463 mm
(18.23 in.)
330 mm
(13.00 in.)
Note: The boundary marked with a ‘B’ shows the cable access hole for all cables.
B006-6641-B000 37
NCR SelfServ 26 ATM Site Preparation
CEN Security Enclosure Bolt Hole Locations The illustration below shows
the dimensions for a standard sleeve ATM configured with a CEN security enclosure.
470 mm
(18.50 in.)
82 mm 265 mm 123 mm
(3.23 in.) (10.43 in.) (4.84 in.)
112 mm
(4.41 in.)
230 mm
(9.06 in.)
A B A
33 mm
A A (1.30 in.)
160 mm
(6.30 in.)
505 mm
(19.88 in.)
330 mm
(13.00 in.)
45 mm 60 mm
(1.8 in.) (2.4 in.)
20 mm 25 mm
(0.78 in.) 45 mm (0.98 in.) 45 mm
(1.77 in.) (1.77 in.)
28 mm 28 mm
(1.1 in.) (1.1 in.)
Note 1: The hole marked with a ‘B’ enables a security alarm sensor to be fitted.
Note 2: The boundary marked with a ‘C’ shows the cable access hole for all cables.
38 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
470 mm
(18.50 in.)
60 mm 270 mm 140 mm
(2.36 in.) (10.63 in.) (5.51 in.)
135 mm 254 mm
(5.31 in.) (10.00 in.)
A A
800 mm 247 mm
(31.50 in.) (9.72 in.)
428 mm
B
(16.85 in.)
175 mm 33 mm
(6.89 in.) (1.30 in.)
A A
118 mm
(4.65 in.)
349 mm
(13.74 in.)
203 mm
(8.00 in.)
Note: The boundary marked with a ‘B’ shows the cable access hole for all cables.
B006-6641-B000 39
NCR SelfServ 26 ATM Site Preparation
CEN Security Enclosure Bolt Hole Locations The illustration below shows
the dimensions for a short sleeve ATM configured with a CEN security enclosure.
470 mm
(18.50 in.)
82 mm 265 mm 123 mm
(3.23 in.) (10.43 in.) (4.84 in.)
112 mm
(4.41 in.)
230 mm
(9.06 in.)
A B A
33 mm
A A (1.30 in.)
160 mm
(6.30 in.)
391 mm
(15.39 in.)
203 mm
(8.00 in.)
45 mm 60 mm
(1.8 in.) (2.4 in.)
20 mm 25 mm
(0.78 in.) 45 mm (0.98 in.) 45 mm
(1.77 in.) (1.77 in.)
28 mm 28 mm
(1.1 in.) (1.1 in.)
Detail of Hole A Detail of Hole B
(All CEN Safes) (Not required on Spanish CEN IV)
Note 1: The hole marked with a ‘B’ enables a security alarm sensor to be fitted.
Note 2: The boundary marked with a ‘C’ shows the cable access hole for all cables.
40 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
Security Bolts
To meet security standards the ATM must be bolted to the floor, through the ‘A’ holes,
using four bolts with anchor washers as specified below. The floor must be capable of
withstanding the loading imposed by the anchor points for the bolts. Bolts and anchor
washers are to be supplied by the owning organisation.
If an adjustable plinth is used, it must be bolted to the floor.
To meet security standards the minimum specification for bolts to secure the ATM to a
concrete floor is high tensile M16 (5/8 in.) bolts with appropriate anchor washers of 6 mm
(0.2 in.) minimum thickness. Bolts should be a minimum depth of 150 mm (5.9 in.) and
either resin anchor bolts or shield anchor type bolts.
Note 1: Bolting of CEN security enclosures should comply with the requirements of EN
1143-1 (CEN Safe Burglary Standard).
Note 2: For CEN L, CEN I and CEN III safes there is an additional fifth central anchoring
hole (hole ‘B’) of a larger counterbored diameter that can be used to fit a special local
alarm sensor.
B006-6641-B000 41
NCR SelfServ 26 ATM Site Preparation
VIDEO CAMERA
Ambient Lighting
If the ATM is fitted with a video camera, it is strongly recommended that there is a
minimum of 50 LUX lighting at floor level within the area illustrated below. This lighting
level conforms to:
z Australian Standard for Automatic Teller Machines (1990)
z Lighting for Automatic Teller Machines as prepared by Illuminating Engineering
Society of North America (1997).
1000 mm
(39.40 in.)
1500 mm
(59.06 in.)
42 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
23 mm
(0.91 in.)
11 mm
89 mm
(0.43 in.)
(3.50 in.)
30 mm
66 mm 34 mm
(1.18 in.)
(2.60 in.) (1.34 in.)
84 mm
A
(3.31 in.)
168 mm
(6.61 in.)
124º
34 mm 100 mm
(1.34 in.) (3.94 in.)
B006-6641-B000 43
NCR SelfServ 26 ATM Site Preparation
If the window next to the Card Reader entry/exit slot is to be customised to indicate card
orientation, the card/decal to be inserted into the window should be of the following
dimensions:
5 mm
(0.20 in.)
Radius
85 mm
(3.34 in.)
54 mm
(2.13 in.)
Note 1: An industry standard credit card can be placed behind the card orientation
window.
44 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
38.5 mm
(1.51 in.)
R 9 mm (0.35 in.)
38.7 mm (1.52 in.)
400 mm
(15.75 in.)
38.5 mm
(1.51 in.)
R 9 mm (0.35 in.)
B006-6641-B000 45
NCR SelfServ 26 ATM Site Preparation
Opaque Window
490 mm
(19.29 in.)
175 mm
(6.89 in.)
46 B006-6641-B000
NCR SelfServ 26 ATM Site Preparation
Clear Window
This decal can be illuminated from behind.
483 mm
(19.02 in.)
168 mm
(6.61 in.)
B006-6641-B000 47
NCR SelfServ 26 ATM Site Preparation
The decals should be a maximum of 0.5 mm (0.02 in.) thick and it is recommended that
they be made from textured polycarbonate with 3M 467 High Performance MP adhesive.
70 mm
(2.76 in.)
12 mm
(0.47 in.)
48 B006-6641-B000
To help NCR maintain the quality of their publications, send comments on the accuracy, clarity,
usability, navigation, organization, and value of this book.
Address correspondence to:
Surface mail address:
NCR Financial Solutions Group Ltd
Information Solutions
Kingsway West
Dundee
Scotland
DD2 3XX
Email address:
userfeedback@exchange.scotland.ncr.com