Professional Documents
Culture Documents
Gas Detection Solutions: Hazardous
Gas Detection Solutions: Hazardous
Gas Detection Solutions: Hazardous
Detection Solutions
▲▲ Best sensor for high temperature and hydrogen detection applications Acoustic Leak Detection
▲▲ Cost-effective solution to detect a broad range of combustible gases FLEXSONIC® ACOUSTIC LEAK DETECTOR
▲▲ Rugged, stainless steel construction ▲▲ Instantaneous response to pressurized gas leaks; no contact with
▲▲ Certified SIL 2 capable when used with FlexVu UD10 Universal Display
® gas required
▲▲ Sensitivity unaffected by wind direction or leak location
▲▲ Foam filter option for protection in dry, sandy environments
Point Toxic Gas Detection ▲▲ Standard base settings useful for most applications
▲▲ Patented Learn Function customizes detection to ignore ultrasonic
GT3000 ELECTROCHEMICAL TOXIC GAS DETECTOR false alarm sources
▲▲ D
etects hydrogen sulfide, hydrogen, oxygen, carbon monoxide, nitrogen ▲▲ exida safety award winner
dioxide, ammonia, chlorine or sulfur dioxide
▲▲ Certified SIL 2 capable (oxygen and hydrogen sulfide) sensors Universal FLEXVU® UNIVERSAL DISPLAY FAMILY
▲▲ Supports both Det-Tronics combustible and toxic gas sensors and
▲▲ Intrinsically safe sensors can be hot-swapped in the field
Displays other 4-20 mA devices
▲▲ Non-intrusive, one-person calibration, logging and diagnostics
POINTWATCH ECLIPSE INFRARED CARBON DIOXIDE GAS DETECTOR
®
▲▲ Easy to integrate and navigate
▲▲ Quickly detects hazardous levels of carbon dioxide
EVENT HISTORIAN
ALUMINUM BODY
ANALOG 4-20 mA
LOOP POWERED
HART DIGITAL
HEATED LCD
IP RATING
▲▲ Proven performance
RELAYS
(EQP)
▲▲ 5-year device warranty
Operating
Temp.
Model Range
FlexVu®
-55 to +75C ▲ ▲ ▲ ▲ 66/67 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
UD10
FlexVu ®
UD20
-20 to +70C ▲ ▲ * 66/67 ▲ ▲ ▲ ▲ ▲
*FlexVu UD20 Universal Display is certified SIL 2 capable when used with the GT3000 Electrochemical Toxic Gas Detector in detecting H2S and O2
®
Multiple Options
Eagle Quantum Premier (EQP) Safety System ®
A B C D E F G H I J K L M N
FAILSAFE OPERATION
and flame safety system with
EVENT HISTORIAN
ANALOG 4-20 mA
LOOP POWERED
HART DIGITAL
automatic releasing for
IP RATING
RELAYS
EQP
pre-action and deluge
▲▲ Meets industry codes,
hazardous location and Operating
third-party performance Model Detected Gases Temp. Range
▲▲ Fault-tolerant communication
COMBUSTIBLE
GAS Bead Sensor gases (including
-55 to +125C ▲ • ▲ • • • • • • <30 UD10
hydrogen)
loop with redundant FlexSight™
Hydrocarbons
LS2000 -55 to +75C ▲ ▲ ▲ ▲ 66/67 ▲ ▲ ▲ ▲ ▲ ▲ 2.0 UD10
controller capability (not hydrogen)
Line-of-Sight
▲▲ Multiple communication H 2 S, CO, O2 , NH3,
protocols, with simple TOXIC
GT3000*
CI , SO2, H2 , NO2
2
-40 to +55C ▲ ▲ ▲ 66/67 ▲ ▲ • • • ▲ ▲ * UD10/20
▲▲ Available preconfigured
Eclipse® CO2
CO2 -40 to +75C ▲ ▲ 66/67 ▲ ▲ ▲ • ▲ ▲ (T50)
UD10
ACOUSTIC
gas panel with 16 inputs LEAK
FlexSonic® Any gas -55 to +75C ▲ ▲ ▲ 66 ▲ ▲ • • • ▲ N/A UD10
Det-Tronics offices
Representative offices
VdS
FlexSonic® Acoustic X3301 Multispectrum PointWatch Eclipse® IR FlexVu® UD10 Universal Display Eagle Quantum Premier ®
Leak Detector IR Flame Detector Combustible Gas Detector with GT3000 Toxic Gas Detector Safety System
92-1066-1.8
Corporate Office
6901 West 110 th Street Phone: +1 952.941.5665 All trademarks are the property of their respective owners.
Minneapolis, MN 55438 USA Toll-free: +1 800.765.3473 © 2019 Detector Electronics Corporation. All rights reserved.
www.det-tronics.com Fax: +1 952.829.8750
Det-Tronics is certified to ISO 9001:2015 in all manufacturing processes.
det-tronics@det-tronics.com