T12-150 Bot.
B2(400X400) 1) THIS DRAWING HAS BEEN PREPARED FROM INFORMATION SUPPLIED
19300
TO US BY THE CUSTOMER, WHO SHOULD CHECK THAT WE INTERPRETED
HIS REQUIREMENTS AND THAT ALL DIMENSION ARE AS REQUIRED AND
PRACTICABLE. THE FOLLOWING DRAWINGS OBTAINED ON LOAN HAVE
BEEN USED TO PREPARE THIS SCHEME.
2500 2500 2500 2500 2500 2500 2500 1800 2) NO SOLEPLATES OR OTHER MEANS OF SPREADING THE IMPOSED
LOADS ARE SUPPLIED BY IBC . THE CUSTOMER MUST ENSURE THAT
B6(200X700) B2(150X400) X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 X11 X12 X13 X14 X15 X16 X17 X18
THE FOUNDATION PROVIDED ARE ADEQUATE .
Y21
3) TYING AND BRACING
B2(150X400)
)
00
B6(250X700)
THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL STRUCTURE
X6
00
Y20
(4
B3
200 STEEL SPIRAL STAIR
RC-SLAB
ARE ADEQUATELY TIED AND OR BRACED TO CARRY THE LOAD AND
B6(400X700)
B6(400X700)
Y19
T12-150 Top
ENSURE STABILITY AS INDICATED ON THE DRAWING WHERE IBC
2500
2500
T12-150 Bot.
B2(400X400)
Y18
2500 2500 2500 2500
19300
2500 2500 2500 1800
EQUIPMENT IS SUPPORTED, SUSPENDED, ANCHORED OR TIED TO AN
t4B
B6(200X700) B2(150X400)
iB5(300X850)
1600200
Y17 B2(150X400) STRUCTURE OR THE GROUND. THE CONTRACTOR MUST ENSURE THAT
3910000
2500
2500
t4D
B6(200X700)
t5B
Y16 B2(150X400)
THE STRUCTURE OR GROUND ADEQUATE TO SAFELY SUPPORT THE
5100900
B2(150X400)
t4B
B5(300X700)
B6(300X700)
B6(200X700)
Y15 200 RC-SLAB B2(150X400)
THE ADDITIONAL IMPOSED LOADS .
B2(150X400)
2500
2500
B2(150X400)
250 RC-SLAB
Y14
t5B
1800000
B2(150X400)
B2(200X700) B2(200X700)
B2(200X700) B2(150X400)
Y13
iB5(300X850)
2500
2500
2400000
B2(150X400) t4A
B2(300X700) B2(150X400) 4) ACCESS SCAFFOLD
12700000
Y12
1800000
B2H
B2(150X400)
THE SUPPLY AND FIXING OF ALL BUILDING TIES IS THE RESPONSIBILITY
B2(150X400)
B2(150X400)
2500
2500
B5(300X700)
B1(200X700)
B1(200X700)
Y11
B2(150X400) t4B T12-150 Top
OF THE CONTRACTOR. ALL TIES TO BE OF THE TWO POSITIVE TYPE
1000000
T12-150 Bot.
21100
B2(150X400)
Y10
t5B
1800
1800
B2(150X400) AS SPECIFIED IN BS 5973 .
iB5(300X850)
t4B
B2(200X700) PT-B(600X1300)
1000000
B2(150X400)
Y9
1300
1300
t4A
2400000
B2(150X400) t4A
2900000
t5A
B7(300X1300)
B7(300X1300)
B6(300X700)
1800
1800
B6(200X700)
B5(300X700)
1800000
Y8 T12-150 Top 200 RC-SLAB 200
T12-150 Bot.
5) SCAFFOLD TUBE AND FITTINGS
B9(300X700)
B6(300X700)
t5D
Y7
2600000
ALL TUBE AND FITTINGS NOT SUPPLIED BY IBC BUT FORMING PART OF
1800
1800
3850000
S406
2
B2(300X300) B6(200X800) PT-B(800X1300) B2(200X700) B2(300X300)
1300
1300
Y6 PT-B(800X1300) PT-B(800X1300) B8(300X700) B9(200X700) THIS STRUCTURE MUST COMPLY WITH BS 1139 .
B6(300X700)
B6(500X700)
B2(150X400)
B2(150X400)
+5.20
@LEVL +5.20
B6(400X700)
B8(300X700)
B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
200
1800
1800
RC-SLAB T12-150 Top B2(150X400)
T12-150 Bot.
@LEVL
PC
B2(150X400) TO PARAPET LEVEL
1300
1300
6) THE DRAWING IS CONFIDENTIAL AND IS EXCLUSIVE PROPERTY OF IBC
B2(150X400)
B6(200X1300) B1(200X700) B2(200X700) B2(200X400) B4(300X700)
Y5 2500 2500 2500 2500 2500 2500 2500 1800
2500
2500
B2(300X300) B2(300X300) B2(300X300) B2(200X400) t4A t4A B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
NO UNAUTHORIZED USE, COPY OR DISCLOSURE IS TO BE MADE AND IT IS
t4A
t4A
B8(200X700) @ +5.20
B4(300X700) @ +3.50
1600200
1600200
B2(150X400)
1775200
3775200
B2(150X400)
Y4 B2(150X400)
B2(300X300) B2(300X300) 1
B4(200X700)
200 RC-SLAB
TO BE RETURNED UPON REQUEST.
B4(250X700)
B4(200X700)
B4(200X700)
B4(300X700)
RC-SLAB S406
200 RC-SLAB B2(300X300) B2(300X300) B2(150X400)
B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
T12-150 Top 200 B2(150X400)
Y3 T12-150 Bot.
B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
t2C t4A t4A
1600200
B2(150X400)
t4A
B2(150X400)
1600200
1600200
1600200
Y1
B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300) B2(300X400)
TO SUPPORT THE FOLLOWING IMPOSED LOADS ONLY.
B4(300X700) B4(300X700)
B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
PC
TO PARAPET LEVEL
SUPPORT:
B2(300X300) B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
B2(300X300)
LIVE LOAD......................................................1.5 KN/SQ. MT
ACCESS:
MAIN WORKING LIFTS NO: AT ...........................KN/SQ.MT.
KEY PLAN
2500
2500
8) THE CUSTOMER MUST ENSURE THAT THE STRUCTURE RESIST ON
FOUNDATION ADEQUATE TO CARRY THE LEG LOADS. SOLE PLATE OR
10) ALL TUBES AND FITTINGS FORMING PART OF THIS STRUCTURE, BUT NOT
SUPPLIED BY IBC MUST CONFORM TO BS1139 OR EQUIVALENT.
B2(150X400) 10) THE DESIGN IS BASED ON THE SAFE WORKING LOAD OF IBC
COMPONENTS AND ALTERATION TO COMPONENTS, ASSEMBLY, LOADING
B2(150X400)
2500
2500
OR ANY OTHER ASPECTS MUST NOT BE MADE WITHOUT THE WRITTEN
AUTHORITY FROM IBC
1800
E...........8035N/SQ.MM
PLYWOOD 18MM DOUGLAS FIR <UNLESS OTHERWISE NOTED>
DEFLECTION HAS BEEN LIMITED TO 1/270 OF THE SPAN OF EACH MEMBER.
B2(150X400) REVISIONS
1300
B2(150X400) 0 08/04/2021 M.D.S N.A WORKING DRAWING
2900000
B7(300X1300)
B7(300X1300)
1800
1800
RC-SLAB 200
1800
1800
S406
2
STANDARD
TOP CUP
PT-B(800X1300) B2(200X700)
1300
1300
PT-B(800X1300) PT-B(800X1300)
B6(500X700)
B2(150X400)
+5.20
B6(400X700)
BOTTOM CUP LEDGERS
1800
1800
B2(150X400) ONELOK NODE POINT
T12-150 Top PROJECT TITLE :
@LEVL
B2(150X400) MAIN CONTRACTOR :
1300
1300
HASHIM GENERAL CONTG.
B2(150X400)
B6(200X1300) B1(200X700) B2(200X700) B2(200X400)
I DEAL BUSINESS COMMUNICATIONS
IBC SCAFFOLDING
EST.
B2(300X300)
B2(300X300)
B2(300X300)
DRAWING TITLE:
DATE :
A1
SCALE :
AS SHOWN
SHEET :
SCALE AS SHOWN M.D.S N.A 08/04/2021 1 OF 2
DRAWING NO. : REV. :
IBC-M100-101-07 0