GENERAL NOTES

T12-150 Bot.
B2(400X400) 1) THIS DRAWING HAS BEEN PREPARED FROM INFORMATION SUPPLIED

19300
TO US BY THE CUSTOMER, WHO SHOULD CHECK THAT WE INTERPRETED
HIS REQUIREMENTS AND THAT ALL DIMENSION ARE AS REQUIRED AND
PRACTICABLE. THE FOLLOWING DRAWINGS OBTAINED ON LOAN HAVE
BEEN USED TO PREPARE THIS SCHEME.

2500 2500 2500 2500 2500 2500 2500 1800 2) NO SOLEPLATES OR OTHER MEANS OF SPREADING THE IMPOSED
LOADS ARE SUPPLIED BY IBC . THE CUSTOMER MUST ENSURE THAT

B6(200X700) B2(150X400) X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 X11 X12 X13 X14 X15 X16 X17 X18
THE FOUNDATION PROVIDED ARE ADEQUATE .

Y21
3) TYING AND BRACING

B2(150X400)

)
00
B6(250X700)
THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL STRUCTURE

X6
00
Y20

(4
B3
200 STEEL SPIRAL STAIR
RC-SLAB
ARE ADEQUATELY TIED AND OR BRACED TO CARRY THE LOAD AND

B6(400X700)

B6(400X700)
Y19
T12-150 Top
ENSURE STABILITY AS INDICATED ON THE DRAWING WHERE IBC

2500

2500
T12-150 Bot.
B2(400X400)
Y18
2500 2500 2500 2500
19300
2500 2500 2500 1800
EQUIPMENT IS SUPPORTED, SUSPENDED, ANCHORED OR TIED TO AN
t4B
B6(200X700) B2(150X400)

iB5(300X850)

1600200
Y17 B2(150X400) STRUCTURE OR THE GROUND. THE CONTRACTOR MUST ENSURE THAT

3910000
2500

2500

t4D
B6(200X700)

t5B
Y16 B2(150X400)
THE STRUCTURE OR GROUND ADEQUATE TO SAFELY SUPPORT THE

5100900
B2(150X400)
t4B

B5(300X700)
B6(300X700)
B6(200X700)
Y15 200 RC-SLAB B2(150X400)
THE ADDITIONAL IMPOSED LOADS .

B2(150X400)

2500

2500
B2(150X400)
250 RC-SLAB
Y14

t5B
1800000
B2(150X400)

B2(200X700) B2(200X700)
B2(200X700) B2(150X400)
Y13

iB5(300X850)
2500

2500

2400000
B2(150X400) t4A
B2(300X700) B2(150X400) 4) ACCESS SCAFFOLD

12700000
Y12

1800000
B2H
B2(150X400)
THE SUPPLY AND FIXING OF ALL BUILDING TIES IS THE RESPONSIBILITY

B2(150X400)
B2(150X400)

2500

2500

B5(300X700)
B1(200X700)

B1(200X700)
Y11
B2(150X400) t4B T12-150 Top
OF THE CONTRACTOR. ALL TIES TO BE OF THE TWO POSITIVE TYPE

1000000
T12-150 Bot.

21100
B2(150X400)
Y10

t5B
1800

1800
B2(150X400) AS SPECIFIED IN BS 5973 .

iB5(300X850)
t4B
B2(200X700) PT-B(600X1300)

1000000
B2(150X400)
Y9

1300

1300
t4A

2400000
B2(150X400) t4A

2900000

t5A
B7(300X1300)

B7(300X1300)
B6(300X700)

1800

1800
B6(200X700)

B5(300X700)
1800000
Y8 T12-150 Top 200 RC-SLAB 200
T12-150 Bot.
5) SCAFFOLD TUBE AND FITTINGS

B9(300X700)

B6(300X700)
t5D

Y7

2600000
ALL TUBE AND FITTINGS NOT SUPPLIED BY IBC BUT FORMING PART OF

1800

1800

3850000
S406
2
B2(300X300) B6(200X800) PT-B(800X1300) B2(200X700) B2(300X300)

1300

1300
Y6 PT-B(800X1300) PT-B(800X1300) B8(300X700) B9(200X700) THIS STRUCTURE MUST COMPLY WITH BS 1139 .

B6(300X700)

B6(500X700)
B2(150X400)
B2(150X400)

+5.20

@LEVL +5.20
B6(400X700)

B8(300X700)
B2(300X300)

B2(300X300)

B2(300X300)

B2(300X300)
200

1800

1800
RC-SLAB T12-150 Top B2(150X400)
T12-150 Bot.

@LEVL
PC
B2(150X400) TO PARAPET LEVEL

1300

1300
6) THE DRAWING IS CONFIDENTIAL AND IS EXCLUSIVE PROPERTY OF IBC
B2(150X400)
B6(200X1300) B1(200X700) B2(200X700) B2(200X400) B4(300X700)
Y5 2500 2500 2500 2500 2500 2500 2500 1800
2500

2500
B2(300X300) B2(300X300) B2(300X300) B2(200X400) t4A t4A B2(300X300)

B2(300X300)

B2(300X300)

B2(300X300)

B2(300X300)
NO UNAUTHORIZED USE, COPY OR DISCLOSURE IS TO BE MADE AND IT IS

t4A

t4A

B8(200X700) @ +5.20
B4(300X700) @ +3.50
1600200

1600200
B2(150X400)

1775200

3775200
B2(150X400)
Y4 B2(150X400)
B2(300X300) B2(300X300) 1

B4(200X700)
200 RC-SLAB
TO BE RETURNED UPON REQUEST.

B4(250X700)

B4(200X700)

B4(200X700)

B4(300X700)
RC-SLAB S406
200 RC-SLAB B2(300X300) B2(300X300) B2(150X400)

B2(300X300)

B2(300X300)

B2(300X300)

B2(300X300)
T12-150 Top 200 B2(150X400)
Y3 T12-150 Bot.

B2(300X300) B2(300X300) B2(150X400)


T12-150 Top B2(150X400) T12-150 Top
T12-150 Bot. T12-150 Bot.
Y2 B2(300X300) B2(300X300)
7) THE STRUCTURE DETAILED IN THIS DRAWING HAS BEEN DESIGNED

B2(300X300)

B2(300X300)

B2(300X300)

B2(300X300)
t2C t4A t4A

1600200
B2(150X400)

t4A
B2(150X400)

1600200

1600200

1600200
Y1
B2(300X300)

B2(300X300)
B2(300X300)

B2(300X300) B2(300X400)
TO SUPPORT THE FOLLOWING IMPOSED LOADS ONLY.
B4(300X700) B4(300X700)

B2(300X300)

B2(300X300)

B2(300X300)

B2(300X300)
PC
TO PARAPET LEVEL
SUPPORT:
B2(300X300) B2(300X300)

B2(300X300) B2(300X300) B2(300X300) B2(300X300) B2(300X300) SELF WEIGHT OF CONCRETE......................25 KN/CU. MT

B2(300X300)

B2(300X300)

B2(300X300)

B2(300X300)

B2(300X300)

B2(300X300)
B2(300X300)

B2(300X300)

B2(300X300)

B2(300X300)
LIVE LOAD......................................................1.5 KN/SQ. MT

B2(150X400) B2(300X300) B2(300X300) B2(300X300) B2(300X300) B2(300X300)

SCAFFOLDING SELFWEIGHT OF FORMWORK.....................0.5 KN/SQ. MT


B2(200X700) B2(200X700)

ACCESS:
MAIN WORKING LIFTS NO: AT ...........................KN/SQ.MT.

B2(200X700) B2(150X400) HOP UP BRACKETS NO. AT ................................................KN/SQ.MT.


ADDITIONAL NUMBER OF BOARDED.
<NON WORKING> LIFTS........ NO.

KEY PLAN
2500

2500
8) THE CUSTOMER MUST ENSURE THAT THE STRUCTURE RESIST ON
FOUNDATION ADEQUATE TO CARRY THE LEG LOADS. SOLE PLATE OR

B2(150X400) OTHER MEANS OF SPREADING THE IMPOSED LOADS ARE TO BE


ARRANGED BY THE CUSTOMER AND WILL NOT BE SUPPLIED BY IBC
MAXIMUM CALCULATED LEG LOAD.

B2(150X400) 9) THE CUSTOMER IS RESPONSIBLE FOR ENSURING THAT ALL STRUCTURES


ARE ADEQUATELY TIED AND/OR ANCHORED TO CARRY THE LOAD AND
ENSURE STABILITY AS INDICATED ON THE DRAWING.

10) ALL TUBES AND FITTINGS FORMING PART OF THIS STRUCTURE, BUT NOT
SUPPLIED BY IBC MUST CONFORM TO BS1139 OR EQUIVALENT.

B2(150X400) 10) THE DESIGN IS BASED ON THE SAFE WORKING LOAD OF IBC
COMPONENTS AND ALTERATION TO COMPONENTS, ASSEMBLY, LOADING

B2(150X400)
2500

2500
OR ANY OTHER ASPECTS MUST NOT BE MADE WITHOUT THE WRITTEN
AUTHORITY FROM IBC

11) ALL TIMBER DESIGN IS THE RESPONSIBILITY OF THE CUSTOMER AND NO


TIMBER IS SUPPLIED BY IBC
WE HAVE ASSUMED THE FOLLOWING.

B2(150X400) MAIN BEARER.......... SECONDARY RUNNER.


THE ABOVE SIZES HAVE BEEN CALCULATED USING
PERMISSIBLE STRESSES AS PER BS 5975.
21100

TIMBER ASSUMED GRADE SC 4.

B2(150X400) BENDING ........8.67 N/SQ.MM


SHEAR ............ 1.34 N/SQ.MM
BEARING .............2.87 N/SQ.MM
1800

1800
E...........8035N/SQ.MM
PLYWOOD 18MM DOUGLAS FIR <UNLESS OTHERWISE NOTED>
DEFLECTION HAS BEEN LIMITED TO 1/270 OF THE SPAN OF EACH MEMBER.

B2(150X400) REVISIONS

B2(200X700) PT-B(600X1300) B2(150X400) REV. NO. DATE REV. BY CHKD. BY REMARKS


1300

1300
B2(150X400) 0 08/04/2021 M.D.S N.A WORKING DRAWING
2900000

B7(300X1300)

B7(300X1300)
1800

1800
RC-SLAB 200
1800

1800
S406
2

STANDARD
TOP CUP

PT-B(800X1300) B2(200X700)
1300

1300
PT-B(800X1300) PT-B(800X1300)
B6(500X700)

B2(150X400)

+5.20
B6(400X700)
BOTTOM CUP LEDGERS
1800

1800
B2(150X400) ONELOK NODE POINT
T12-150 Top PROJECT TITLE :

T12-150 Bot. ALSADIYIAT MOSQUE

@LEVL
B2(150X400) MAIN CONTRACTOR :
1300

1300
HASHIM GENERAL CONTG.
B2(150X400)
B6(200X1300) B1(200X700) B2(200X700) B2(200X400)
I DEAL BUSINESS COMMUNICATIONS
IBC SCAFFOLDING
EST.

2500 2500 2500 2500 2500 2500 2500 1800


B2(300X300) B2(300X300) B2(200X400)
B2(300X300)

B2(300X300)

B2(300X300)

B2(300X300)

DRAWING TITLE:

BIRDCAGE SCAFFOLDING LAYOUT


( INSIDE MOSQUE )

BIRDCAGE SCAFFOLDING LAYOUT JOB NO. :


IBC-M100-101-1220
DESIGNED BY : CHECKED BY :
FORMAT :

DATE :
A1
SCALE :
AS SHOWN
SHEET :
SCALE AS SHOWN M.D.S N.A 08/04/2021 1 OF 2
DRAWING NO. : REV. :
IBC-M100-101-07 0