Proportional Pressure Relief Valve Types (Z) DBE and (Z) DBEE
Proportional Pressure Relief Valve Types (Z) DBE and (Z) DBEE
02
Replaces: 12.98
Nominal size 6
Series 1X
H/A 3598/93
Maximum operating pressure 315 bar
Maximum flow 30 L/min
Type DBEE 6..-1X/...G24K31... with integrated control electronics
© 2002
by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main
All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using
electronic systems, in any form or by means, without the prior written authorisation of Bosch Rexroth AG. In the event of
contravention of the above provisions, the contravening party is obliged to pay compensation.
This document was prepared with the greatest of care, and all statements have been examined for correctness. This
document is subject to alterations for reason of the continuing further developments of products. No liability can be
accepted for any incorrect or incomplete statements.
Preferred types
Type DBEE Type ZDBEE
Material No. Type Material No. Type
R900954432 DBEE 6-1X/50YG24K31M R900954434 ZDBEE 6 VP2-1X/50G24K31M
R900919359 DBEE 6 -1X/100YG24K31M R900954435 ZDBEE 6 VP2-1X/100G24K31M
R900954433 DBEE 6-1X/200YG24K31M R900954436 ZDBEE 6 VP2-1X/200G24K31M
R900546987 DBEE 6-1X/315YG24K31M R900954437 ZDBEE 6 VP2-1X/315G24K31M
T A(Y)
T P A 2 B T
9 1 8 7 3 2 5 6 4 12
occurring and at the same time increases the component service life.
For the selection of filters see catalogue sheets RE 50 070, RE 50 076 and RE 50 081
2) Separate order, see page 5
Note: For details regarding the environmental simulation test covering EMC (electro-magnetic compatibility), climate
and mechanical loading see RE 29 158-U (declaration regarding environmental compatibility).
30 30
To amplifier
For types DBEE, ZDBEE (with integrated control electronics)
Plug-in connector to E DIN 43 563-BF6-3/Pg11
Separate order under Material No. R900021267
(plastic version)
91
AF
Ø27
B
C E
Ø6,5…Ø11
Funetion
The control of the integrated electronics is via the two differential
The current regulator controls the solenoid current independently
amplifier connections D and E. from the solenoid coil resistance.
The ramp generator produces from a command value jump (0 to At potentiometer R30 the increase of the command value-current-
10 V or 10 to 0 V) a delayed increase or decrease in the solenoid
characteristic curve, and thereby also the increase rate of the command
current. At potentiometer R14 the rate of increase in time and at
value-pressure-characteristic curve of the proportional pressure valve
potentiometer R13 the rate of decrease in time of the solenoid current
may be altered.
can be set. The potentiometer R43 is used to adjust the biasing current. This
The ramp times of 5 s is only possible over the complete command
setting should not be altered. If necessary, the zero point of the
value range. With smaller command value changes the ramp time is
command value-pressure-characteristic curve can be adjusted at the
accordingly shortened. valve seat.
Via the characteristic curve generator, the command value-solenoid
The power stage of the electronics for the control of the proportional
current characteristic curve is so matched to the valve, that non-
solenoid forms a chopper amplifier. It is pulse width modulated with
linearities in the hydraulics can be compensated for, so that a linear
a pulse frequency of 300 Hz.
command value-pressure-characteristic curve is obtained. The solenoid current may be measured at the two measurement
sockets MP1 and MP2. A voltage drop of 0.352 V at the measurement
resistor relates to a solenoid current of 1.6 A.
Block circuit diagram / pin allocation of the integrated control electronics
Supply voltage
Power supply with rectification
Single phase rectification or three phase bridge: Ueff = 22 to 33 V
Residual ripple at power supply: < 5 %
Min. supply voltage in V →
RE 29 158/12.98
158/11.02 6/10 (Z)DBE; (Z)DBEE
Characteristic curves (measured with HLP 46; ϑoil = 40 °C ± 5 °C )
Pressure in ports P or P2 in relation to the command value (qV = 5 L/min)
Pressure stage 50 bar (external and internal) Pressure stage 100 bar (external and internal)
60 120
Pressure in P or P2 in bar →
Pressure in P or P2 in bar →
50 100
40 80
30 60
20 40
10 20
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Command value in % → Command value in % →
Pressure stage 315 bar (external and internal)
350
Pressure stage 200 bar (external and internal)
240 300
Pressure in P or P2 in bar →
Pressure in P or P2 in bar →
200 250
160 200
120 150
80 100
40 50
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Command value in % → Command value in % →
60 125
Pressure in P or P2 in bar →
50 100
40 75
30 50
20 25
10
0 5 10 15 20 25 30
0 5 10 15 20 25 30 Flow in L/min →
Flow in L/min → Pressure stage 315 bar
400
350
Pressure in P or P2 in bar →
300
Pressure stage 200 bar
Pressure in P er P2 in bar →
250 250
200 200
150 150
100 100
50 50
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Flow in L/min → Flow in L/min →
The characteristic curves were measured without back pressure at port A (external pilot oil drain) and T (internal pilot oil drain).
With an internal pilot oil drain the pressure in P or P2 increases by the pressure acting in port T.
Min. settable pressure at port P or P2 with a 0 command value Pilot oil drain –––––– internal – – – external
Pressure stage 50 bar Pressure stage 100 bar
14 14
Min. settable pressure in bar →
8 8
6 6
4 4
2 2
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Flow in L/min → Flow in L/min →
Pressure stage 200 bar Pressure stage 315 bar
14 14
Min. settable pressure in bar →
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Flow in L/min → Flow in L/min →
The characteristic curves were measured without back pressure at port A (external pilot oil drain) and T (internal pilot oil drain).
With an internal pilot oil drain the pressure in P or P2 increases by the pressure acting in port T.
4 4
3 3
2 2
1 1
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Flow in L/min → Flow in L/min →
Pressure differential T1 → T2
5
Pressure differential in bar →
0 5 10 15 20 25 30
Flow in L/min →
204,9
99,4 19,5
7 6 9 2 8
Ø 10
15
Ø 5,5
87
1,3+0,1
50
42
Ø 12,2+0,1
1 3 5; 10 4
27,8±0,1
19±0,1
10,3±0,1
32,5±0,1
31±0,1
45
A B
P
0,75
5,95
26,55±0,1
16,25±0,1
40,5±0,1 15,4
"1"
15
Ø 5,5
87
50
1,3+0,1
Ø 12,3+0,1
"3"
2 10 4 3 1
27,8±0,1
19±0,1 "2"
10,3±0,1
62
T
32,5±0,1
31±0,1
A B
45
P
5,95
26,55±0,1
16,25±0,1
0,75
62
11 40,5±0,1
"4"
"1" to "4" – position of the plug-in connector or the housing with control electronics (see ordering details)