Professional Documents
Culture Documents
Standard: 5 300 HP 3 PHASE 50/60 HZ
Standard: 5 300 HP 3 PHASE 50/60 HZ
STANDARDFEATURES
In addition to those features commonly found in packaged DC
drives, the following salient features are standard in the
Pacemaster 6:
-
8 NEMA POWER CODE C Six SCR full wave power converter for
..
. Three phase.fused. blower motor starter
Auxiliary Contacts
AC Line Circuit Breaker
on "M" Contactor.
for AC line circuit breaker
. Line Inductors
. Anti-plug relay
..
. Additional control relays
Special DC Field Voltage
Speedand Load Meters
SPECIFICATIONS
RATINGS PERFORMANCE CHARACTERISTICS
HorsepowerRange ,.., .. 5-300HP SpeedRange:
AC Line Input Voltage. . . . . . 230 or 460V with Armature Feedback.......... 30:1
AC Line Frequency. . . . , . . . 50 or 60 Hz with Tach Feedback. . . . . . . . . . . . 100:1
3Phase SpeedRegulation:
DC Output Voltages: with Armature Feedback. . . . . . . . . ~
230VAC Supply:
Armature "" Q-240VDC
with Tach Feedback. . . . . . . . . . . . :to"
Field. .. . .. . .. . . .. . . 150VDC Minimum Load
460VAC Supply: for stable operation ............. 5~
Armature ............ Q-SOOVDC Efficiency
Field ... 300VDC (Rated Speed/Rated Load) ....... ... 96~
ServiceFactor
............ 1.0 DisplacementPower Factor. . . . . . . . . 88~
Duty. . . . . . . . . . . . . . . . . . . . . . . . . .. Continuous (Typical)
Maximum Load Capacity. . . .. 15004for 1 minute ADJUSTMENTS
Power Conversion. . . . . . . . . NEMA Power Code C Accel/Decel............ 3-120 sec (LinearTime)
Maximum Field Amperes. . . . 10.0 Current Limit ........... 0-150% (of Full Load)
MaximumSpeed ........ 70-110% (of Base Motor Speed)
OPERATING CONDITIONS Minimum Speed ......... . 0-33% (of Base Motor Speed)
Line Voltage Variation. . . . . . . . . . .. +10% to -5% of Nominal IR (Load) Compensation. . . 0-10% (of Rated DC Voltage)
Line Frequency Variation. . . . . . . . . . . . . . . . . . . . . . .. :1:3 Hz
Speed Adjustment
AmbientTemperature ...... OOtoSSOC(32°t0131°F) with External 1<XX>
Ohm
Relative Humidity. ........ S to 95% (without condensation) 2WattPot........... 0 to 1~
Altitude. . . . . . . . . . . . . . . . . . to3300Fl(1000M) (of Rated Speed)
3 PHASE 3 PHASE
Field Field NON-REVERSING
Arm Max Arm Max
Motor Input DC DC Input DC DC 5-20 21 x11x11'h 24x24x12
I Horse AC Amps Amps AC Amps Amps 230 25-40 21 x 21 x 11'h 3Ox24x12
Power Amps (240Y) (150Y) Amps (SOOY) (300Y) 50-100 S9x21x12 42x30x12
5 20 20 5 12 10 5 5. 40 21 x 17 x 11'h 24 x 24 x 12
7.5 29 29 5 15 14 5 50. 75 27x21 x11'h 30 x 24 x 12
10 38 38 5 19 18 5 460 100- 200 39x27x12 42x30x12
15 54 55 5 27 27 5 250. 300 57 x33 x 15~ 6Ox36x16
20 70 72 5 33 34 5
25 86 89 5 43 43 5 REVERSING
30 101 106 5 50 51 5 5-20 21 x 21 x 11'h 24 x24 x 12
40 132 140 5 64 67 5 230 25-40 33 x 27 x 11'h 36x30x12
50 162 173 5 79 83 5 50-100 39 x 33 x 12 42x36x12
60 193 206 5 93 99 5
255 10 119 123 10 5- 40 21 x21 x11'h 24 x 24 x 12
75 240
10 156 164 10 50- 75 33 x 27 x 11'h 36 x 30 x 12
100 317 341 460
193 205 10 100 200 39 x33 x 12 42 x36 x 12
125
150 229 246 10 250- 300 56x44x15% 72 x 48 x 16
200 307 330 10 NOTE: Dimensionsshown are for the basic packageddrive.
250 375 405 10 The addition of options may change dimensions.
300 442 480 10 Certified mounting dimensions supplied upon request.