Brosur Panel

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 86

240 Series DIN Panel Meters

An extensive range of 48, 72, 96 and 144mm DIN style panel meters offering
measurement of all electrical and electronic parameters. Meters are shock resistant
and vibration proof and supplied with terminal covers. A selection of slide in dials
and customised options are available.

Movements
In Crompton Instruments’ world-patented ‘Hi-Q’ taut band suspension, all the
delicate parts of the traditional instruments are eliminated. There are no pivots, no
jewel bearings, no hair-springs and no air damping vane. Instead, a tough platinum
ribbon suspends the moving element between front and rear tension springs.
Specially contoured pads are fitted to the ends of the spindle, and the working gap at
each end is filled with a high quality silicon fluid. The pads, together with the fluid
reservoir, form a system which acts as a resilient built-in shock absorber. This
provides both rotational and longitudinal damping as the moving element floats on
oil with no bearing friction and is effectively cushioned against shock and vibration.
360° Synchroscopes and power factor meters have robust pivot and jewel bearings
Features with oil damping.
An extensive range of specialist
measuring meters in 4 case sizes Dials, Scales and Pointers
Standard dials are matt white with black printed scales and bar knife-edge pointers.
Shock resistant taut band suspension
Black dials with white or yellow scales and pointers are also available.
Vibration-proof Hi-Q damping Interchangeable slide in dials are used on models 242, 243 and 244 90° moving iron,
Slide in dials for 90°current, voltage and moving coil and frequency meters.
frequency on models 242, 243 and 244 General options include red supplementary pointers, red indexes (quadrant scales),
red, green or blue lines, bands or segments, finely spaced divisions, multi-scales,
Terminal covers supplied as standard special scales and captions to customer' requirements.

Benefits Illumination
Low cost Internal illumination is available in the following models:
Local indication • 244 and 246 shortscale moving coil and moving iron vane.
• 243, 244 and 246 longscale moving coil and moving iron vane.
Ease of installation
Through dial (Translucent) illumination on 244 and 246 models.
Minimal training Edge illumination on 243, 244 and 246 models.
Low maintenance Replaceable 6, 12 or 24V lamps are used on all models except 243 longscale meters,
Customised options and features where the lamps are internal.

Applications Specification
Performance BSEN60051
Switchgear
Measuring Ranges DIN 43701
Distribution systems Accuracy Overload BSEN60051
Generator sets Dimensions DIN 43700
Scale Marking Generally DIN43802
Control panels
Magnetic Influence BSEN60051
Energy management Safety IEC414
Building management Terminals Clamp strap M4 up to 25A. Clamp strap M8 over 25A
Humidity Range Up to 95% RH (non condensing)
Utility power monitoring
Test Voltage @50Hz 2kV RMS for 1 minute
Process control Overload AC Current x 1.2 continuous x 10 for 5 seconds
Motor control Overload AC Voltage x 1.2 continuous x 2 for 5 seconds
Frequency See main pages for other instruments
Approvals Damping Time Less than 3 seconds is standard. More heavily damped
movements are available on request.
LRS and BV Approvals.
Standard Calibration 23°C
Operating Temperature -20°C to +60°C
Enclosure Code IP54 as standard (to BSEN60529). IP55 consult factory
Terminals IP20B with terminal cover or terminal
boots fitted
Case Grade UL94V0
Base Grade UL94V1

8
240 Series DIN Panel Meters

DIN 16257 symbol meaning for Specification Continued


calibration position Case Dimensions and panel cutout conform to IEC473, DIN
43700. Models 242, 243 and 244 have cases and bezels
Vertical injection moulded in flame retardant engineering
thermoplastic, recognised by Underwriters Laboratory
materials specification. All 246 models have pressed
steel cases.
Horizontal Bezel Slim-line DIN43802 black as standard
Bezel Window Standard sheet glass, with zero adjusters where
appropriate. Non reflecting glass or polycarbonate
shatterproof windows are available.
Installation Installations in switchboard panel or mosaic
Inclined 60° arrangement on equipment or machine with a panel
thickness of up to 40mm in a horizontal or vertical
plane. Installation Category III
Inclination of dial surface to the Fixing on Panel Models 242, 243 and 244 – 2 corner fixing clamps and
horizontal e.g 60°. tensioning thumb screws
Required orientation must always be Model 242 – available with a one piece ‘push on’ clamp.
stated when ordering if other than Model 246 - 2 side fixing spring clips
vertical mounting is required. Mounting Position Normal vertical mounting or as indicated on the scale
in accordance with DIN 16257. A deviation of ±15° is
permissible
Approvals Lloyds Shipping (LRS), Bureau Veritas (BV), EMC and LVD

Dimensions
Model 242 243 244 246
Bezel ‘A’ 48 x 48 72 x 72 96 x 96 144 x 144
Panel cut-out ‘B’ 45 x 45 68 x 68 92 x 92 138 x 138
Scale Length: 90° 42 65 94 145
Scale Length: 240° 72 112 150 230
Maximum overall depth ‘C’:
Ammeters and Voltmeters A.C. & D.C.* 64 64 64 60
Ammeters and Voltmeters with switch* – – 64 –
Dual Meters* – – 64 –
C Elapsed Time Meter/Hours Run* 64 64 64 –
Maximum Demand Indicator* – 64 64 60
Combined MDI & MI Indicator* – – 64 60
Maximum Demand Indicator with relay* – – 90 –
Frequency Meter 90°* 64 64 64 60
A Frequency Meter 240°* § § 120 125
Phase Angle, Power Factor Meter 90°* § § 107 §
240°* § § 107 §
M.C. Indicator with separate transducer* 64 64 64 60
Dynamometer 360° Synchroscope* – – 120 125
Dynamometer 360° Power Factor Meter* – – 120 –
A Phase Sequence Indicator* – 64 64 –
Position Indicator* § § 120 125
Speed Indicator* 64 64 64 60
Temperature Indicators* – – 120 125
Quadra Meters* – – 64 –
Panel cut-out Impulse Counters* 64 64 64 –
Wattmeter, Varmeter 90° § § 107 125
Maximum Panel B
Wattmeter, Varmeter 240° § § 107 125
thickness 10mm Model 244-21Y & 244-21Z – – 142 –
LED Synchroscope & Synchro Check Relay – – 80 –
LED 360° Synchroscope – – 80 –

§ Indicator Only
B * If separate terminal cover is used add 20 mm to dimension C
– Not available

9
240 Series DIN Panel Meters

Moving Coil Rectified A.C. Ammeters and Voltmeters


For high frequency or linear full scale A.C. measurements, these instruments
measure average values of sinusoidal waveforms and are scaled in r.m.s. values.
The high quality silicon bridge rectifier gives a linear scale down to near zero, where
some compression occurs.

Specification – Short Scale


Accuracy: 1.5% ES
Ratings: Ammeters: Model 242 from 250µA to 20mA
Model 243 from 250µA to 1A Models 244/246 from 250µA to 20A
Voltmeters: 15V to 600V a.c. direct connected
Models available for use with V.T.s
Frequency: 50/60Hz, (Single Frequencies 25Hz to 3kHz on request)

Connections Product Codes – Short Scale


A.C. Ammeter Bezel Size mm 48 72 96 144
Scale length mm 42 65 94 145
Product Codes
Ammeters 242-89B 243-01B 244-01B 246-10B
Voltmeters 242-89W 243-01W 244-01W 246-10W

Specification – Long Scale


Accuracy: 1.5 % ES
Ratings: Ammeters: 250µA to 1A A.C.Up to 30A on models 244/246-05B
Voltmeters: 15V to 600V Direct connected
A.C. Voltmeter Models available for use with V.Ts
Frequency: 50/60Hz. (Single frequencies 25Hz to 3kHz on request)

Product Codes – Long Scale


Bezel Size mm 48 72 96 144
Scale length mm 72 112 150 230
Product Codes
Ammeters 242-05B 243-05B 244-05B 246-05B
Voltmeters 242-05W 243-05W 244-05W 246-05W

Dual A.C. Ammeters and Voltmeters


The two instruments in one case can be used for independent measurement of 2
parameters or the comparison of the two inputs. For example, when an A.C.
generator is to be connected in parallel with mains supply where voltage, phase and
frequency must coincide.

Specification
Accuracy: 1.5% ES
Ratings: Ammeter: 250µA to 10A A.C.
Voltmeter: 15 to 600V direct connected
Frequency: 50/60Hz (single frequencies 25Hz to 3kHz on request)

Product Codes
Bezel Size mm 96
Scale length mm 65
Product Codes
Ammeters 244-80F
Voltmeters 244-80L
Dual A.C. Ammeter Dual A.C. Voltmeter
Direct Connected

13
240 Series DIN Panel Meters

Moving Coil D.C. Ammeters and Voltmeters


Moving Coil Meters are suitable for all D.C. systems. The linear scale is calibrated
down to zero and the accuracy maintained down to 10%. High currents are measured
with separate shunts and suitably scaled indicators. Suppressed, centre and offset
zero models are available.

Specification
Accuracy: Class 1.5
Ratings: Ammeters: 100µA to 25A, (200µA for 05 model)
4/20mA suppressed zero
40A for model 243/244-01A
Voltmeters: 50mV to 600V
1/5V suppressed zero
50, 60, 75, 100, 150mV for use with shunts
Impedance: Ammeters: 75mV internal shunt above 60mA
Connections Voltmeters: 1000Ω/V above 1V
D.C. Ammeter
Further details on our T-Sheet T118 available on request.

Product Codes – Short Scale


Bezel Size mm 48 72 96 144
Scale length mm 42 65 94 145
Product Codes
Ammeters 242-89A 243-01A 244-01A 246-10A
Ammeters suppressed zero 242-89R 243-01R 244-01R 246-10R
D.C. Voltmeter Voltmeters 242-89V 243-01V 244-01V 246-10V
Voltmeters suppressed zero 242-89S 243-01S 244-01S 246-10S

Product Codes – Long Scale


Bezel Size mm 48 72 96 144
Scale length mm 72 112 150 230
Product Codes
Ammeter 242-05A 243-05A 244-05A 246-05A
Ammeters suppressed zero 242-05R 243-05R 244-05R 246-05R
Voltmeters 242-05V 243-05V 244-05V 246-05V
Voltmeters suppressed zero 242-05S 243-05S 244-05S 246-05S

Moving Coil Dual D.C. Ammeters and Voltmeters


Dual instruments can be used to measure a wide range of currents and voltages,
and save both space and time by requiring only one panel cut-out.
The 244-80M allows for independent measurement of two D.C. currents in one case.
The 244-80E allows for independent measurement of two D.C. voltages in one case.

Specification
Accuracy: Class 1.5
Ratings: D.C. Current: 100µA to 25A direct connected
Connections 4/20mA suppressed zero.
Dual D.C. Ammeter D.C. Volts: 50mV to 600V
1/5 volt suppressed zero
50, 60, 75, 150mV for use with shunts.

Product Codes
Bezel Size mm 96
Scale length mm 94
Product Code
Dual D.C. Voltmeter
Ammeters 244-80M
Voltmeters 244-80E

18
240 Series DIN Panel Meters

360° LED Synchroscope and Synchro Check Relay


Where manual parallelling of two A.C. systems is desired, the frequency of both
systems can be monitored by an LED Synchroscope. The systems are synchronised
when the green LED is lit in the 12 o’clock position. The instrument is rated for
continuous operation and connection. Where semi-automatic parallelling of two A.C.
systems is desired, the voltage, phase displacement and the frequency of both
systems can be monitored by an LED Synchroscope and Synchro Check Relay.
Voltage, Phase angle and time delay controls are provided. The systems are
synchronised when the green triangular LEDs are lit together with the GEN/BUS
green LEDs. A dead bus option is also available.

Specification
Ratings Voltage: 63.5, 110, 120, 220, 230, 240, 380, 400, 415, 440, 480V
110/120V (115V Nominal)
220/240V (230V nominal)
Connections 380/480V (430V nominal)
360° LED Synchroscope Volts A.C. or via V.T.
Frequency: 40/65Hz
Burden at 50Hz: 4VA maximum
Suitable for single or three phase systems
Safety: IEC1010-1 (300V A.C. rms installation degree 2)
Dielectric: 4kV rms for 1 minute
Isolation: BUS/GEN/RELAY
Vibration: To Lloyds shipping specification
*Phase difference: +0 to 20°. +/-1°
*Voltage difference: +0 to 20% +/-2%
0 to 10% for models G & H
*Time Delay: 0 to 2.5 seconds +10%
*Accuracy: Synchronisation at T.D.C. is +1˚
*360° LED Synchroscope and Synchro Check Relay Only.

360° LED Synchroscope and Synchro Product Codes


Check Relay Bezel Size mm 96 96 96
Scale Length mm 360° LED 360° LED 360° LED
3 or 4 Wire Synchroscope Synchroscope Synchroscope
40-65Hz and Synchro Check and Synchro
Check Relay
Relay (Dead Bus)
Product Code
110/120V – 244-14GG-POBX 244-14HG-POBX
220/240V – 244-14GG-R5BX 244-14HG-R5BX
380/480V – 244-14GG-RUBX 244-14HG-RUBX
63.5V 244-14AG-NXYY 244-14LG-NXBX 244-14DG-NXBX
110V 244-14AG-PMYY 244-14LG-PMBX 244-14DG-PMBX
220V 244-14AG-R4YY 244-14LG-R4BX 244-14DG-R4BX
230V 244-14AG-RQYY 244-14LG-RQBX 244-14DG-RQBX
240V 244-14AG-RRYY 244-14LG-RRBX 244-14DG-RRBX
380V 244-14AG-RUYY 244-14LG-RUBX 244-14DG-RUBX
400V 244-14AG-SCYY 244-14LG-SCBX 244-14DG-SCBX
415V 244-14AG-SBYY 244-14LG-SBBX 244-14DG-SBBX
440V 244-14AG-SHYY 244-14LG-SHBX 244-14DG-SHBX
480V 244-14AG-SEYY 244-14LG-SEBX 244-14DG-SEBX
For the 244-14L and 244-14D models, the generator voltage is compared to the
nominal input (bus) voltage specified at time of ordering. For the 244-14G and
244-14H models, the generator voltage is compared to the measured bus voltage.

24
®

dseGenset

dse8610 MKII
ENVIRONMENTAL TESTING STANDARDS

ELECTRO MAGNETIC COMPATIBILITY


BS EN 61000-6-2
SYNCHRONISING AUTO START LOAD SHARE EMC Generic Immunity Standard for the
Industrial Environment
CONTROL MODULE BS EN 61000-6-4
EMC Generic Emission Standard for the
Industrial Environment

ELECTRICAL SAFETY
The DSE8610 MKII is an easy to Designed to offer increased built in KEY LOAD SHARE FEATURES: BS EN 60950
use Synchronising Auto Start support for active sensors for 0 V • Peak lopping/sharing (with Safety of Information Technology Equipment,
Control Module suitable for use in a to 10 V & 4 mA to 20 mA. appropriate DSE mains including Electrical Business Equipment
multi-generator loadshare system, Comprehensive communication controller) TEMPERATURE
designed to synchronise up to 32 and system expansion options are • Sequential set start BS EN 60068-2-1
generators including electronic and available. • Manual voltage/frequency Ab/Ae Cold Test -30 oC
BS EN 60068-2-2
non-electronic engines. adjustment Bb/Be Dry Heat +70 oC
Using the DSE PC Configuration • R.O.C.O.F. and vector shift
VIBRATION
The DSE8610 MKII monitors the Suite Software allows easy protection BS EN 60068-2-6
generator and indicates operational alteration of the operational • Generator load demand Ten sweeps in each of three major axes
status and fault conditions, sequences, timers and alarms. With • Automatic hours run balancing 5 Hz to 8 Hz at +/-7.5 mm, 8 Hz to 500 Hz at 2 gn
automatically starting or stopping all communication ports capable of • Mains (Utility) decoupling HUMIDITY
the engine on load demand or fault being active at the same time, the • Mains (Utility) decoupling BS EN 60068-2-30
condition. DSE8610 MKII is ideal for a wide test mode Db Damp Heat Cyclic 20/55 oC at 95% RH
48 Hours
variety of demanding load share • Dead bus sensing BS EN 60068-2-78
System alarms are annunciated on applications. • Bus failure detection Cab Damp Heat Static 40 oC at 93% RH
the LCD screen (multiple language • Direct governor and AVR control 48 Hours
options available), illuminated LED • Volts and frequency matching SHOCK
and audible sounder. • kW and kvar load sharing BS EN 60068-2-27
• Dead bus synchronising Three shocks in each of three major axes
15 gn in 11 mS
The event log will record 250 events
to facilitate easy maintenance, and DEGREES OF PROTECTION
PROVIDED BY ENCLOSURES
an extensive number of fixed and BS EN 60529
flexible monitoring, metering and IP65 - Front of module when installed into the
control panel with the supplied sealing gasket.
protection features are included.

COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY


OF LOAD SHARE APPLICATIONS
DSE2130 MODEM MODBUS PC
DSE2131
DSE2133
DSE2152 2 12 8 4
DSE2157
DSE2548 232 485

DSENET ®
RS232 AND USB USB CONFIGURABLE DC OUTPUTS ANALOGUE EMERGENCY DC POWER
EXPANSION RS485 PORT HOST INPUTS SENDERS STOP SUPPLY 5-35V
+
ETHERNET

MSC
DEUTZ DETROIT
ISUZU IVECO
DSE8610 MKII MSC PERKINS JOHN DEERE
CATERPILLAR LOMBARDINI
MTU SISU
8xxxMKII
7 VOLVO JCB DIESELMAX
55xx 75xx 8xxx CUMMINS YANMAR
OTHER SCANIA AND OTHERS

BUS VOLT FREE GENERATOR SENSING FUEL & START CHARGE ELECTRONIC MAGNETIC
SENSING OUTPUTS OUTPUTS ALTERNATOR ENGINES PICK-UP
CURRENT VOLTS
D+
+ W/L

1ph 2 1ph 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N E/N N

ISSUE 3
®

dseGenset

dse8610
SPECIFICATION

MKII DC SUPPLY
CONTINUOUS VOLTAGE RATING

SYNCHRONISING AUTO START LOAD SHARE 5 V to 35 V Continuous

CONTROL MODULE CRANKING DROPOUTS


Able to survive 0 V for 100 mS, providing
supply was at least 10 V before dropout
and supply recovers to 5 V. This is
achieved without the need for internal
batteries.LEDs and backlight will not be
maintained during cranking.

MAXIMUM OPERATING CURRENT


530 mA at 12 V, 280 mA at 24 V

MAXIMUM STANDBY CURRENT


320 mA at 12 V, 160 mA at 24 V

CHARGE FAIL/EXCITATION RANGE


0 V to 35 V

GENERATOR & BUS


VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)
KEY FEATURES • 2 configurable volt-free relay KEY BENEFITS
• Comprehensive synchronising & outputs • Compatible in load share systems FREQUENCY RANGE
loadsharing capabilities • 4 configurable analogue/digital containing DSE5500, DSE7500, 3.5 Hz to 75 Hz

• Built in governor and AVR control inputs DSE8000 and DSE8600 MKII MAGNETIC PICKUP
• Base load (kW export) control • Built in sensors to support 0 V to series. Contact DSE for further VOLTAGE RANGE
• Positive & negative kVAr export 10 V & 4 mA to 20 mA details +/- 0.5 V to 70 V

control • 12 configurable digital inputs • 132 x 64 pixel ratio display for FREQUENCY RANGE
• Mains (Utility) decoupling • Configurable 5 stage dummy load clarity 10,000 Hz (max)
protection and load shedding outputs • Real-time clock provides accurate
INPUTS
• 4-Line back-lit LCD text display • CAN, MPU and alternator event logging DIGITAL INPUTS A TO L
• Multiple Display Languages frequency speed sensing in one • Ethernet communication, provides Negative switching
• Five key menu navigation variant builit in advanced remote ANALOGUE INPUTS A TO D
• LCD alarm indication • Real time clock monitoring. Configurable as:
• Heated display option available • Manual and automatic fuel pump • Can be integrated into building Negative switching digital input
0 V to 10 V sensor
• Customisable power-up text and control management systems (BMS) and
0 Ω to 480 Ω sensor
4 mA to 20 mA sensor
images • Engine run-time scheduler programmable logic control (PLC)
• DSENet expansion compatibility • Fuel usage monitor and low fuel • Increased input and output ® OUTPUTS
• Data logging & trending facility level alarms expansion capability via DSENet OUTPUT A & B (FUEL & START)
• Internal PLC editor • Simultaneous use of all • Licence-free PC software 15 A DC at supply voltage
• Protections disable feature communication ports • IP65 rating (with supplied gasket)
OUTPUTS C & D
• Fully configurable via PC using • Remote SCADA monitoring via offers increased resistance to water 8 A AC at 250 V AC (Volt-free)
USB, RS232, RS485 & Ethernet various DSE software applications ingress
communication • MODBUS RTU & TCP support • Advanced Internal PLC editor allows AUXILIARY OUTPUTS E TO L
2 A DC at supply voltage
• Front panel configuration with PIN with configurable MODBUS user configurable functions to meet
protection pages for integration into building specific application requirements. BUILT IN AVR GOVERNOR CONTROL

500 Ω
• Power save mode management systems (BMS) MINIMUM LOAD IMPEDANCE
• 3 phase generator sensing and • Advanced SMS messaging EXPANSION DEVICES Fully isolated
protection (additional external modem • DSE124 CAN/MSC Extender
• Generator current and power required) • DSE2130 Input Expansion Module GAIN VOLTAGE
0 V to 10 V DC
monitoring (kW, kvar, kVA, pf) • Start & stop capability via SMS • DSE2131 Ratio-metric Input Fully isolated
• kW and kvar overload alarms messaging Expansion Module
• Reverse power alarms • 3 configurable maintenance • DSE2133 RTD & Thermo-couple OFFSET VOLTAGE
0 V to 10 V DC
• Over current protection alarms Expansion Module Fully isolated
• Unbalanced load protection • Compatible with a wide range of • DSE2152 Ratio-metric Output
• Independent earth fault protection CAN engines, including tier 4 Expansion Module DIMENSIONS
OVERALL
• Breaker control via fascia buttons engine support • DSE2157 Output Expansion 245 mm x 184 mm x 51 mm
• Fuel and start outputs • Uses DSE Configuration Suite PC Module 9.6” x 7.2” x 2.0”
configurable when using CAN Software for simplified • DSE2548 LED Expansion Module
PANEL CUT-OUT
• 8 configurable DC outputs configuration 220 mm x 160 mm
8.7” x 6.3”

MAXIMUM PANEL THICKNESS


8 mm
0.3”

-40 °C to +85 °C
RELATED MATERIALS STORAGE TEMPERATURE RANGE

-40 °F to +185 °F
TITLE PART NO’S
DSE8610 MKII Installation Instructions 053-182
DSE8610 MKII Operator Manual 057-254
-30 °C to +70 °C
OPERATING TEMPERATURE RANGE
DSE8610 MKII PC Configuration Suite Manual 057-238
-40 °F to +185 °F

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com
Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-204/09/15 (1)
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457
TYPICAL WIRING DIAGRAM DEEP SEA ELECTRONICS 053-182
A larger diagram is available in the operators manual.
8610M KII INST ALL ATION INSTRUCTIONS ISSUE 1

ACCESSING THE FRONT PANEL CONFIGURATION EDITOR.


 Ensure the engine is at rest and the module is in STOP mode by pressing the (Stop/Reset)
button.

 Press the (Stop/Reset) and (Info) buttons simultaneously.


 If a module security PIN has been set, the PIN number request is then
shown :
 Press the (Tick) button the first digit will flash to enable the pin to be
entered.

 Press (up) or (down) to adjust it to the correct value

 Press (right) when the first digit is correctly entered. The digit you have just entered will now
show ‘#’ for security.

 Repeat this process for the other digits of the PIN number. You can press (left) if you need
to move back to adjust one of the previous digits.
 When (Tick) is pressed after editing the final PIN digit, the PIN is checked for validity. If the
number is not correct, you must re-enter the PIN.

 If the PIN has been successfully entered (or the module PIN has not been
enabled), the editor is displayed :

EDITING A PARAMETER

 Enter the editor as described above.

 Press the (Right) or (Left) to cycle to the section you wish to view/change. Then

 press (Up) or (Down) to cycle to the parameter within the section you have chosen.

DIMENSIONS AND MOUNTING  To edit the parameter, press (Tick) to enter edit mode. The parameter begins to flash to indicate
For flat surface mounting in a Type 1 enclosure to meet UL requirements that you are editing the value.
 Press the up or down buttons to change the parameter to the required value.
DIMENSIONS PANEL CUTOUT:
240.0mm x 181.1mm x 41.7mm (9.4” x 7.1” x 1.6”) 220mm x 160mm (8.7” x 6.3”)  Press (Tick) to save the value. The parameter ceases flashing to indicate that it has been saved.

 To exit the editor at any time, press and hold the (Stop/ Reset) or (Tick) button.
Deep Sea Electronics Plc. Deep Sea Electronics inc.
Tel:+44 (0)1723 890099 Phone: +1 (815) 316-8706
Fax: +44 (0)1723 893303 Fax: +1 (815) 316- 8708 NOTE: When the editor is visible, it is exited after 5 minutes of inactivity to ensure security.
Email: support@deepseaplc.com TOLL FREE (USA only) : Tel: 1 866 636 9703
Web: www.deepseaplc.com Email: dsesales@deepseausa.com NOTE: The PIN number is automatically reset when the editor is exited (manually or automatically) to ensure security.
Web: www.deepseausa.com
NOTE: Comprehensive module configuration is possible using the DSE Configuration Suite PC Software, refer to DSE publication
057-239 DSE8610 MKII & DSE8610 MKII Configuraiton Suite PC Software Manual.
ADJUSTABLE PARAMETERS Front Panel Configuration Editor (continued)

Front Panel Configuration Editor (Factory default settings are shown in bold italicised text) Section Parameter as shown on display Values
Timers LCD Page Timer 0h 0m 0s
Section Parameter as shown on display Values Scroll Delay 0h 0m 0s
Display Contrast 0% Engine Pre Heat Timer 0h 0m 0s
Language English, Other. Engine Crank Duration 0h 0m 0s
Current Date and Time hh:mm Engine Crank Rest Time 0h 0m 0s
Engine Oil Pressure Low Shutdown 0.00 bar Engine Safety On Delay 0h 0m 0s
Oil Pressure Low Pre Alarm 0.00 bar Engine Smoke Limiting 0h 0m 0s
Coolant Temp high Pre Alarm 0 ºC Engine Smoke Limiting Off 0h 0m 0s
Coolant Temp High Shutdown 0 ºC Engine Warm Up Time 0h 0m 0s
Start Delay Off Load 0h 0m 0s Engine Cool Down Time 0h 0m 0s
Start Delay Telemetry 0h 0m 0s Engine Speed Overshoot Delay 0h 0m 0s
Engine Pre Heat Timer 0h 0m 0s Engine Failed To Stop Delay 0h 0m 0s
Engine Crank Duration 0h 0m 0s Battery Under Voltage Warning Delay 0h 0m 0s
Engine Crank Rest Time 0h 0m 0s Battery Over Voltage Warning Delay 0h 0m 0s
Engine Safety On Delay 0h 0m 0s Return Delay 0h 0m 0s
Engine Smoke Limiting 0h 0m 0s Generator Transient Delay 0h 0m 0s
Engine Smoke Limiting Off 0h 0m 0s Scheduler Scheduler Active / Inactive
Engine Warm Up Time 0h 0m 0s Schedule On Load Active / Inactive
Engine Cool Down Time 0h 0m 0s Schedule Period Weekly, Monthly
Engine Speed Overshoot Delay 0h 0m 0s
Engine Speed Overshoot 0h 0m 0s Schedule Time & Date Selection (1-16) Press to begin editing then or when selecting the
Engine Failed To Stop Delay 0h 0m 0s different parameters in the scheduler.
Battery Under Voltage Warning Active / Inactive
Battery Under Voltage Warning Delay 0h 0m 0s
Battery Under Voltage Warning 0V ACCESSING THE ‘RUNNING’ CONFIGURATION EDITOR
Battery Over Voltage Warning Active / Inactive
Battery Over Voltage Warning Delay 0h 0m 0s  The ‘running’ editor can be entered while the engine is running. All protections remain active if the
Battery Over Voltage Warning 0V engine is running while the running editor is entered.
Charge Alternator Failure Warning Active / Inactive
Charge Alternator Failure Warning 0V
Charge Alternator Warning Delay 0h 0m 0s
 Press and hold the (Tick) button to enter the running editor.
Charge Alternator Failure Shutdown Active / Inactive
Generator Under Voltage Shutdown 0V ADJUSTABLE PARAMETERS (Running editor)
Under Voltage Pre-Alarm 0V
Loading Voltage 0V  Enter the editor as described above.
Nominal Voltage 0V
Over Voltage Pre-Alarm 0V
Over Voltage Shutdown 0V
Under Frequency Shutdown 0 Hz
Under Frequency Pre-Alarm 0 Hz  Press the (Up) or (Down) buttons to cycle to the section you wish to view/change.
Loading Frequency 0 Hz
Nominal frequency 0 Hz
Over Frequency Pre-Alarm 0 Hz
Over Frequency Shutdown 0 Hz  To Edit the parameter press the (Tick) button to enter edit mode. The parameter begins to flash to
Full Load Rating 00 A indicate that you are editing the value.
kW Overload Trip 0%
Delayed Over current Active / Inactive
Gen Over Current Trip 0%
AC System 3 Phase 4 Wire
CT Primary 0A Power Cycle After Exit  Press the (Up)or (Down) buttons to change the parameter to the required value.
CT Secondary 0A Power Cycle After Exit
Short Circuit Trip 0%
Earth CT Primary
Earth Fault Trip
0A
Active / Inactive
 Press the (Tick) button to save the value. The parameter ceases flashing to indicate that it has
Earth Fault Trip 0% been saved.
Transient Delay 0h 0m 0s
Gen Reverse Power Delay 0h 0m 0s  To exit the editor at any time , press and hold the (Tick) button.
Full kW Rating 0 kW
Full kVAr Rating 0 kvar
Load Ramp Rate 0%
Running Editor
Load Level For More Sets 0%
Load Level For Less Sets 0% Section Parameter as shown on display Values
Load Demand Priority 1 Display Contrast 0%
Gen Reverse Power 0 kW Language English, Other
Insufficient Capacity Delay 0h 0m 0s Load Demand Priority 1
Insufficient Capacity Action None / Indication / Warning / Shutdown / Electrical Trip Load Power Factor 0%
Reactive Load CTL Mode None / VAr Share Load Parallel Power 0%
Load Parallel Power 0 kW When In Mains Parallel Mode ) Commissioning Screens Active / Inactive
Load Power Factor 0% When In Mains Parallel Mode Override Starting Alarms Active / Inactive
Enable MSC Compatibility Active / Inactive Voltage Adjust (manual mode only engine running breaker open) 0%
Continued Overleaf Frequency Adjust (manual mode only engine running breaker open) 0%
Lembar data produk NSYCVF85M230PF
Karakteristik ClimaSys forced vent. IP54, 85m3/h, 230V, with
outlet grille and filter G2

Price* : 1.116.000,00 IDR

Disklaimer: Dokumentasi ini tidak ditujukan sebagai pengganti dan tidak untuk digunakan untuk menentukan kesesuaian atau keandalan produk ini untuk aplikasi pengguna
Main
Range ClimaSys
Product name ClimaSys CV
Product or component type Fan
Type of filter Standard
Flow rate Free flow rate with standard filter: 85 m3/h at 50 Hz
Free flow rate with standard filter: 98 m3/h at 60 Hz
[Us] rated supply voltage 175...253 V
Input voltage 230 V 50/60 Hz

Complementary
Absorbed power 15 W 60 Hz
17 W 50 Hz
[In] rated current 0.121 A 50 Hz
0.097 A 60 Hz
Noise level < at 46…49 dB
Bearing type Ball
Height 170 mm external:
Width 150 mm external:
Depth 62 mm external:
Cut-out dimensions 125 x 125 mm
Net weight 0.78 kg
Material Outlet grille: injected thermoplastic (ASA PC)
Colour Outlet grille: grey (RAL 7035)
Ambient air temperature for operation -20…60 °C
Ambient air temperature for storage -40…70 °C
Maximum pressure 50 Pa flow rate 0 m³/h
Connections - terminals Faston connector
IP degree of protection IP54
Device composition 1 axial motor
2 protective grille: on the front and rear surfaces
1 filter: front of axial motor
1 outlet grille: front
1 cut-out template
13 Feb 20
1
1 power cord
Condition of use Flow rates depends on the work point, see ProClima software
Surrounding environment must be relatively clean
Filter must be cleaned and replaced regularly
Overfrequent filter replacement should be avoided
Outside temperature must be 5 °C lower than inside temperature

Offer Sustainability
REACh free of SVHC Yes
EU RoHS Directive Compliant
EU RoHS Declaration
Toxic heavy metal free Yes
Mercury free Yes
RoHS exemption information Yes
China RoHS Regulation China RoHS declaration
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Contractual warranty
Warranty 12 months

2
Product datasheet NSYCR150WU2C
Characteristics ClimaSys PTC heating resistance
150W,110-250V insulate

Main

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Range ClimaSys
Product name ClimaSys CR
Product or component type Resistance heater
Power range 150 W
Input voltage 110...250 V AC 50/60 Hz
Electrical connection 4 screw terminals 2.5 mm²

Complementary
Operating position Vertical
Ambient air temperature for operation -40…70 °C
IP degree of protection IP20
Electrical insulation class Class II
Product certifications VDE
UL
Material Body: extruded aluminium
Cover: plastic
Height 150 mm external:
Width 60 mm external:
Depth 90 mm external:
Condition of use Electrical protection is needed
Heaters must be installed with a thermal controller
Air sealed enclosure
Fixing mode By clips
Mounting support 35 mm DIN rail

Offer Sustainability
REACh free of SVHC Yes
EU RoHS Directive Compliant
EU RoHS Declaration
Mercury free Yes
RoHS exemption information Yes
China RoHS Regulation China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information
13 Feb, 2020
1
WEEE The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins

Contractual warranty
Warranty 18 months

2
Product data sheet REL91283
Characteristics

Main
Range of product RelayAux
Product or component type Fast trip and lockout relay

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Coil type Low consumption
[Uc] control circuit voltage 110 V DC (- 20 % + 10 % Un)
Product compatibility REL91351 (front connection socket)
REL91360 (flush mounting socket)
Status LED Without
Control type Manual reset
Automatic reset

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
Local signalling Mechanical indicator (red)contact position:

This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Complementary
Contacts type and composition 8 C/O
Insulation resistance > 100 MOhm at 500 V DC conforming to IEC 60255-5
[Uimp] rated impulse withstand voltage 5 KV during 1.2/50 µs conforming to IEC 60255-5
Contacts material AgNi
[Ie] rated operational current 10 A
Inrush current 80 A during 200 ms
200 A during 10 ms
Making capacity 40 A during 0.5 s at 110 V DC
Mechanical durability 10000000 Cycles
Power consumption in W High consumption: 500 W - peak (< 2 ms)
Low consumption: 1.4 W - permanent
High consumption: 45 W
Maximum pick up duration 10 Ms
Contact resistance 30 MOhm
Inter contact distance 1.8 Mm
Mechanical robustness Shocks 11 ms (5 gn) conforming to IEC 60068-2-27
Bumps 16 ms (10 Gn) conforming to IEC 60068-2-29
Height 50 Mm
Width 90 Mm
Depth 100.5 Mm
Net weight 0.6 Kg

May 21, 2020


1
Environment
Dielectric strength 2 KV 50 Hz 1 min conforming to IEC 60255-5
Relative humidity 93 % at 40 °C
Electromagnetic compatibility Conducted and radiated emissions criteria A conforming to EN 55022
Conducted and radiated emissions criteria B conforming to EN 55022
Electrostatic discharge - test level: 15 kV level 4 (air discharge) conforming-
to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV level 4 (contact discharge) conforming-
to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test lev-
el: 10 V/m, 80 MHz...1 GHz level 3 conforming to IEC 61000-4-3
Radiated radio-frequency electromagnetic field immunity test - test lev-
el: 10 V/m, 80 MHz...1 GHz level 3 conforming to ENV 50204
Electrical fast transient/burst immunity test - test level: 4 kV, 5 kHz lev-
el 4 (1 min) conforming to IEC 61000-4-4
Surge immunity test - test level: 2 kV level 3 (common mode) conforming-
to IEC 61000-4-5
Surge immunity test - test level: 1 kV level 3 (differential mode) conforming-
to IEC 61000-4-5
Conducted RF disturbances - test level: 10 V, 0.15...80 MHz level 3 conforming-
to IEC 61000-4-6
Magnetic field at power frequency - test level: 100 A/m level 5 (continuous) con-
forming to IEC 61000-4-8
Magnetic field at power frequency - test level: 1000 A/m level 5 (2 s) conforming-
to IEC 61000-4-8
Damped oscillating waves - test level: 2.5 kV, 1 MHz level 3 (common mod-
e) conforming to IEC 60255-22-1
Damped oscillating waves - test level: 1 kV, 1 MHz level 3 (differential mod-
e) conforming to IEC 60255-22-1
Environmental characteristic Exposure to cold in operation conforming to IEC 60068-2-1
Exposure to cold in storage conforming to IEC 60068-2-1
Continuous exposure to damp heat in storage 56 d (93 %) conforming to 40 °C-
conforming to IEC 60068-2-78
Salt mist in storage conforming to ISO 9227
Exposure to dry heat in operation conforming to IEC 60068-2-2
Exposure to dry heat in storage conforming to IEC 60068-2-2
Vibration resistance 1 gn (f = 58…150 Hz) conforming to IEC 60068-2-1
+/- 0.075 mm (f = 10…58 Hz) conforming to IEC 60068-2-1
IP degree of protection IP40 conforming to IEC 60529
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -25…70 °C
Fire resistance 850 °C during 30 s
Operating altitude < 2000 m
Directives 92/31/EEC - electromagnetic compatibility
89/336/EEC - electromagnetic compatibility
93/68/EEC - low voltage directive
72/23/EEC - low voltage directive
Product certifications UL listed file E322124
CE
RoHS

Offer Sustainability
EU RoHS Directive Not applicable, out of EU RoHS legal scope

Product Life Status : Commercialised

2
5 The efficiency
Acti 9
generations Acti 9 Exclusive new features give you the safest,
Unmatched, aesthetically attractive design ‘You can tell it’s a
simplest, and most efficient installations
high-quality product

you deserve
Unparalleled high-quality fit and finish
when you hold it’
of industry experience and 21 new patents The most flexible and innovative low-voltage modular system
make Acti 9 the new reference in low-voltage
Acti 9TM gives you unmatched efficiency, reduces design and installation time, eliminates
modular systems down time, and makes your business even more competitive. It simplifies you final distribution
operations with the right solution for every application. It even adds control and communication
capabilities, integrating easily with any facility management system and adapting to the dynamic
requirements of tertiary and industrial lighting applications.

VisiTrip TM
Acti 9 Smartlink

Connects Acti 9 devices in one-click, for easy


Fast location of integration with any facility management system
the faulty outgoer
minimizes down time

VisiSafe TM

Take your next step with these FREE materials


from Schneider Electric™
100%
recyclable and
Acti 9
Visit www.SEreply.com and enter key code or call 000-000-0000
recoverable The complete high-performance
materials, RoHS modular system for final distribution Guaranteed safe
intervention on-site
compliant, and
REACH

Read how energy


and environmental
Achieve permanent
change through
Sign up for our
FREE, flexible
Move from
‘business as usual’
Front Face EverPlug TM

responsibility lie at the


core of the Schneider
measurement,
monitoring, and control
training so you can
develop new, more
to becoming a long-
term, sustainable Class 2 Reflex™ iC60
Electric strategy. of your energy usage. efficient solutions. green corporation.

Enter key code Enter key code Enter key code Enter key code
78176T 78176T 78176T 78176T

Schneider Electric Industries SAS


Head Office
35 rue Joseph Monier
92500 Rueil Malmaison Cedex- France
Continuous safety QuickVigi™ screwless All-in-one concept
Tel.: +33 (0)1 41 29 70 00
for operators and feature allows integrated control
www.schneider-electric.com
non-qualified fast, safe, secure circuit breaker of
©2011 Schneider Electric. All Rights Reserved. Schneider Electric, Acti 9, Vigi, VisiSafe, EverPlug, Reflex, ™ personnel connections the Acti 9 system
QuickVigi, Multiclip, Distribloc, Energy University, and VisiTrip are trademarks owned by Schneider Electric
Industries SAS or its affiliated companies. All other trademarks are property of their respective owners.
Design: Global Marketing, Communications Strategy and Design 998-2918_GMA
Technical Surge arresters type 2 or 3 iPF, iPRD

Acti 9 The safest, simplest, and most efficient


characteristics
Type 1P, 1P+N, 2P, 3P, 3P+N, 4P
‘When I install the Acti 9 I know I don’t
system for power distribution solutions
I max (kA) 8, 20, 40, 65
have to come back to the job’. Standards IEC 61643-1, IEC 61643-11
Degree of protection IP20/IP40

Circuit Electrical Installation systems Control


Integrated remote control MCBs Reflex iC60N, iC60H
breakers auxiliaries Contactors,
Circuit breakers iC60 N, H, L, LMA iK60 N
IP20B terminals, Curves B, C, D
1 pole Tripping, notification, splitter block, impulse relays, ICU (A) at 400V - IEC/EN 60898-1 6000, 10000, 15000 6000
Type 2P, 3P, 4P
1 pole + neutral indication, and remote full range of mounting indicator lights, pushbuttons, ICU (kA) at 415V - IEC/EN 60947-2 10, 15, 20, 25, 50, 70, 100
Rating (A) 10, 16, 25, 40
2 poles status indication and wiring accessories, kilowatt hour meters, and Type 1P, 1P+N, 2P, 3P, 4P 1P, 1P+N, 2P, 3P, 4P
Standards IEC 60947-2
3 poles communicating architecture selector switches, etc. Rating (A) 0,5 to 63 1 to 63
30 000 cycles (AC1)
4 poles Curves B, C, D B, C Electrical endurance 6,000 cycles (AC5 a/b)
50 000 cycles (AC21)
Standards IEC/EN 60947-2, 60898-1 IEC/EN 60898-1

Residual current devices Vigi iC60 iDPN Vigi Control iCT iTL iPB iSSW iIL iEN, iME
Function Contactors Impulse Relays Push-buttons Switches Indicator Lights Kilowatt hour meters
RCD Type AC, A, SI AC, A, SI
single single single phase
Type 2P, 3P, 4P 1P + N 1P, 2P double double three phases
Type 1P, 2P, 3P, 4P 1P, 2P, 3P, 4P
3P, 4P single + flashing light three phases
Rating (A) 25, 40, 63 4 to 40 indicator light voltage presence neutral
Standards IEC/EN 61009-1 IEC/EN 61009-1 Rating (A) 16, 25, 40, 63,100 16 & 32 20 20 to 125 40 to 6000

Sensitivity (mA) 10, 30, 100, 300, 300 S , 10, 30, 100, 300
500, 500 S , 1000 S

Connection between iC60 and iC60 Vigi ‘Quick connection’ up to 40A

Type 2 or 3
1 pole Residual current circuit breakers iID iIDK
1 pole + neutral
RCD Type Asi, A, AC, B AC
2 poles Lighting, time and energy management
3 poles Type 2P, 4P 2P, 4P
MIN IH, IHP, ITM IC TH, THP CDS STD, SCU
3 poles + neutral Rating (A) 16 to 125 25, 40, 63
Silent electronic Programmable and Standard and Standard and Single and Dimmers
4 poles Standards IEC/EN 61008-1 IEC/EN 61008-1 and electromechanical mechanical time programmable twilight weekly programmable three-phase
timers switches switches thermostats load-shedders
Automatic Surge arresters Sensitivity (mA) 10, 30, 100, 300, 300 S , 500, 500 S 30, 300

recloser
auxiliaries Electrical auxiliaries and mounting accessories
2 poles 2 poles
2 poles 3 poles 3 poles
4 poles 4 poles 4 poles
Residual current Vigi residual current Integrated remote
circuit breaker device module control circuit breaker Installation and wiring Multiclip™ splitter block Acti 9 Smartlink Distribloc™ splitter block
Rating (A) 80 -- 63

100% 100% 100% 15% 0% Degree of protection IP20 IP20 IP20

safe for installers and coordination preventative time saved on down time best choice for
users in the most between MCB maintenance design and industrial and
severe environments and actuator installation tertiary buildings Combined iOF, iSD, iMN, iMX, and iMSU electrical auxiliaries between iC60 circuit breakers and iID
Terminal shields, interpole barrier, screw shields, plug-in
base, padlocking device, clip-on terminal markers, and
residual current circuit breakers, automatic recloser (ARA), and remote control auxiliaries (RCA)
rotary handle
Product data sheet LV429289
Characteristics

Main
Product or component type Plug-in kit

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Accessory / separate part category Mounting accessory
Range compatibility Compact NSX circuit breaker
Compact NSX DC circuit breaker
Circuit breaker name Compact NSX160
Compact NSX250
Compact NSX100
Poles description 3P

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Complementary

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Mounting mode Plug-in
[In] rated current 250 A

Offer Sustainability
Sustainable offer status Green Premium product
EU RoHS Directive
Compliant EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised

May 21, 2020


1
Product data sheet LV429434
Characteristics

Main
Device short name Motor mechanism module with SDE adaptor

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Product or component type Motor mechanism
Device application Automatic spring charging
Range compatibility Compact NSX circuit breaker
Compact NSX DC circuit breaker
circuit breaker
Product compatibility PowerPact H-Frame
PowerPact J-Frame
[In] rated current 160 A

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
100 A

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
[Uc] control circuit voltage 208...277 V AC 60 Hz
220...240 V AC 50/60 Hz

Complementary
Control type Standard
Control signal type Impulse
Maintained
Mounting mode Fixed
Response time < 600 ms (opening)
< 80 ms (closing)
Maximum operating frequency 4 per minute
Maximum power consumption in VA 500 VA closing
500 VA opening
Provided equipment SDE adaptor
Locking options description Padlocking in OFF position
1 to 3 padlocks Ø 5 to Ø 8

Offer Sustainability
Sustainable offer status Green Premium product
EU RoHS Directive
Compliant EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile

May 21, 2020


1
Contractual warranty
Warranty 18 months

Product Life Status : Commercialised

2
May 21, 2020
Characteristics
Product data sheet
LV430841

1
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Main
Range Compact
Product name Compact NSX
Device short name Compact NSX160N
Product or component type Circuit breaker
Device application Distribution
Poles description 3P
Protected poles description 3t
[In] rated current 125 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
Utilisation category Category A
Breaking capacity 10 KA at 600 V AC 50/60 Hz conforming to UL 508
85 KA at 240 V AC 50/60 Hz conforming to UL 508
10 KA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 KA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 KA at 480 V AC 50/60 Hz conforming to UL 508
36 KA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 KA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 KA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 KA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code N 50 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Mounting mode Fixed

Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 KV
[Ics] rated service breaking capacity 10 KA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 KA at 525 V AC 50/60 Hz conforming to IEC 60947-2
36 KA at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 KA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 KA at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 KA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 40000 Cycles
Electrical durability 10000 Cycles 440 V In/2 conforming to IEC 60947-2
15000 Cycles 690 V In/2 conforming to IEC 60947-2
20000 Cycles 440 V In conforming to IEC 60947-2
7500 Cycles 690 V In conforming to IEC 60947-2
Mounting support Backplate
Upside connection Front
Downside connection Front
Connection pitch 35 Mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 125 A at 40 °C
Long time pick-up adjustment type Ir Adjustable
Long time pick-up adjustment range 0.7...1 x In
Long time delay adjustment type Fixed
[tr] long-time delay adjustment range 120…400 S at 1.5 x In
15 S at 6 x Ir
Short-time pick-up adjustment type Isd Fixed
[Isd] short-time pick-up adjustment range 1250 A
Short-time delay adjustment type Fixed

2
Auxiliary contact composition Without
Local signalling Positive contact indication
Width 105 Mm
Height 161 Mm
Depth 86 Mm
Net weight 2.2 Kg

Environment
Standards EN/IEC 60947
UL 508
Product certifications EAC
CCC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -55…85 °C

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive
Compliant EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised

3
May 21, 2020
Characteristics
Product data sheet
LV431831

1
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Main
Range Compact
Product name Compact NSX
Device short name Compact NSX250N
Product or component type Circuit breaker
Device application Distribution
Poles description 3P
Protected poles description 3t
[In] rated current 200 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
Utilisation category Category A
Breaking capacity 85 KA at 240 V AC 50/60 Hz conforming to UL 508
10 KA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 KA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 KA at 480 V AC 50/60 Hz conforming to UL 508
36 KA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 KA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 KA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 KA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
15 KA at 600 V AC 50/60 Hz conforming to UL 508
Breaking capacity code N 50 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Mounting mode Fixed

Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 KV
[Ics] rated service breaking capacity 10 KA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 KA at 525 V AC 50/60 Hz conforming to IEC 60947-2
36 KA at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 KA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 KA at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 KA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 Cycles
Electrical durability 10000 Cycles 440 V In conforming to IEC 60947-2
10000 Cycles 690 V In/2 conforming to IEC 60947-2
20000 Cycles 440 V In/2 conforming to IEC 60947-2
5000 Cycles 690 V In conforming to IEC 60947-2
Mounting support Backplate
Upside connection Front
Downside connection Front
Connection pitch 35 Mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 200 A at 40 °C
Long time pick-up adjustment type Ir Adjustable
Long time pick-up adjustment range 0.7...1 x In
Long time delay adjustment type Fixed
[tr] long-time delay adjustment range 120…400 S at 1.5 x In
15 S at 6 x Ir
Short-time pick-up adjustment type Isd Adjustable
[Isd] short-time pick-up adjustment range 5...10 x In
Short-time delay adjustment type Fixed

2
Auxiliary contact composition Without
Local signalling Positive contact indication
Width 105 Mm
Height 161 Mm
Depth 86 Mm
Net weight 2.4 Kg

Environment
Standards EN/IEC 60947
UL 508
Product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -55…85 °C

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive
Compliant EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised

3
Product data sheet LV432538
Characteristics

Main
Product or component type Plug-in kit

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Accessory / separate part category Mounting accessory
Range compatibility Compact NSX circuit breaker
Compact NSX DC circuit breaker
Circuit breaker name Compact NSX630
Compact NSX400
Poles description 3P

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
Complementary

This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Mounting mode Plug-in
[In] rated current 630 A

Offer Sustainability
Sustainable offer status Green Premium product
EU RoHS Directive
Compliant EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised

May 21, 2020


1
Product data sheet LV432641
Characteristics

Main
Device short name Motor mechanism module

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Product or component type Motor mechanism
Device application Automatic spring charging
Range compatibility Compact NSX circuit breaker
Compact NSX DC circuit breaker
circuit breaker
Product compatibility PowerPact L-Frame
[In] rated current 400 A
630 A

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
[Uc] control circuit voltage 208...277 V AC 60 Hz

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
220...240 V AC 50/60 Hz

Complementary
Control type Standard
Control signal type Impulse
Maintained
Mounting mode Fixed
Response time < 600 ms (opening)
< 80 ms (closing)
Maximum operating frequency 4 per minute
Maximum power consumption in VA 500 VA closing
500 VA opening
Locking options description Padlocking in OFF position
1 to 3 padlocks Ø 5 to Ø 8

Offer Sustainability
Sustainable offer status Green Premium product
EU RoHS Directive
Compliant EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised


May 21, 2020
1
May 21, 2020
Characteristics
Product data sheet
LV432693

1
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Main
Range Compact
Product name Compact NSX
Device short name Compact NSX400N
Product or component type Circuit breaker
Device application Distribution
Poles description 3P
Protected poles description 3t
[In] rated current 400 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
Utilisation category Category A
Breaking capacity 85 KA at 240 V AC 50/60 Hz conforming to UL 508
22 KA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
85 KA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
10 KA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
30 KA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
20 KA at 600 V AC 50/60 Hz conforming to UL 508
50 KA at 480 V AC 50/60 Hz conforming to UL 508
50 KA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
42 KA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code N 50 kA 415 V AC
Trip unit name Micrologic 2.3
Trip unit technology Electronic
Trip unit protection functions LSoI
Control type Toggle
Mounting mode Fixed

Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 KV
[Ics] rated service breaking capacity 11 KA at 525 V AC 50/60 Hz conforming to IEC 60947-2
85 KA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
10 KA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
50 KA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
30 KA at 500 V AC 50/60 Hz conforming to IEC 60947-2
42 KA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 15000 Cycles
Electrical durability 12000 Cycles 440 V In/2 conforming to IEC 60947-2
3000 Cycles 690 V In conforming to IEC 60947-2
6000 Cycles 440 V In conforming to IEC 60947-2
6000 Cycles 690 V In/2 conforming to IEC 60947-2
Mounting support Backplate
Upside connection Front
Downside connection Front
Connection pitch 45 Mm
Protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating 400 A at 40 °C
Long time pick-up adjustment type Ir Adjustable 9 settings
Long time pick-up adjustment range 0.9...1 x Io
Long time delay adjustment type Fixed
[tr] long-time delay adjustment range 16 S at 6 x Ir
Thermal memory 20 minutes before and after tripping
Short-time pick-up adjustment type Isd Adjustable 9 settings
[Isd] short-time pick-up adjustment range 1.5...10 x Ir

2
Short-time delay adjustment type Fixed
Instantaneous pick-up adjustment type Ii Fixed
Instantaneous pick-up adjustment range 4800 A
Auxiliary contact composition Without
Local signalling LED 90 % Ir
LED 105 % Ir
LED ready
Width 140 Mm
Height 255 Mm
Depth 110 Mm
Net weight 6.05 Kg

Environment
Standards EN/IEC 60947
UL 508
Product certifications EAC
CCC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -55…85 °C

Offer Sustainability
Sustainable offer status Green Premium product
EU RoHS Directive
Compliant EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised

3
May 21, 2020
Characteristics
Product data sheet
LV432893

1
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Main
Range Compact
Product name Compact NSX
Device short name Compact NSX630N
Product or component type Circuit breaker
Device application Distribution
Poles description 3P
Protected poles description 3t
[In] rated current 630 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
Utilisation category Category A
Breaking capacity 85 KA at 240 V AC 50/60 Hz conforming to UL 508
22 KA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
85 KA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
10 KA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
30 KA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
20 KA at 600 V AC 50/60 Hz conforming to UL 508
50 KA at 480 V AC 50/60 Hz conforming to UL 508
50 KA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
42 KA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code N 50 kA 415 V AC
Trip unit name Micrologic 2.3
Trip unit technology Electronic
Trip unit protection functions LSoI
Control type Toggle
Mounting mode Fixed

Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 KV
[Ics] rated service breaking capacity 11 KA at 525 V AC 50/60 Hz conforming to IEC 60947-2
85 KA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
10 KA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
50 KA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
30 KA at 500 V AC 50/60 Hz conforming to IEC 60947-2
42 KA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 15000 Cycles
Electrical durability 6000 Cycles 690 V In/2 conforming to IEC 60947-2
2000 Cycles 690 V In conforming to IEC 60947-2
4000 Cycles 440 V In conforming to IEC 60947-2
8000 Cycles 440 V In/2 conforming to IEC 60947-2
Mounting support Backplate
Upside connection Front
Downside connection Front
Connection pitch 45 Mm
Protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating 630 A at 40 °C
Long time pick-up adjustment type Ir Adjustable 9 settings
Long time pick-up adjustment range 0.9...1 x Io
Long time delay adjustment type Fixed
[tr] long-time delay adjustment range 16 S at 6 x Ir
Thermal memory 20 minutes before and after tripping
Short-time pick-up adjustment type Isd Adjustable 9 settings
[Isd] short-time pick-up adjustment range 1.5...10 x Ir

2
Short-time delay adjustment type Fixed
Instantaneous pick-up adjustment type Ii Fixed
Instantaneous pick-up adjustment range 6900 A
Auxiliary contact composition Without
Local signalling LED ready
LED 90 % Ir
LED 105 % Ir
Width 140 Mm
Height 255 Mm
Depth 110 Mm
Net weight 6.2 Kg

Environment
Standards EN/IEC 60947
UL 508
Product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -55…85 °C

Offer Sustainability
Sustainable offer status Green Premium product
EU RoHS Directive
Compliant EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised

3
Product data sheet XB5AA35
Characteristics black flush complete pushbutton Ø22 spring
return 1NO+1NC unmarked

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range of product Harmony XB5
Product or component type Push-button
Device short name XB5
Bezel material Plastic
Dark grey plastic
Head type Standard
Fixing collar material Plastic
Mounting diameter 22 mm
Sale per indivisible quantity 1
Shape of signaling unit head Round
Type of operator spring return
Operator profile Green flush, unmarked
Contacts type and composition 1 NO + 1 NC
Contact operation Slow-break
Connections - terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end conforming to EN/IEC 60947-1

Complementary
Height 42 mm
Width 30 mm
Depth 52 mm
Terminals description ISO n°1 (13-14)NO
(21-22)NC
Resistance to high pressure washer 7000000 Pa at 55 °C, distance : 0.1 m
Contacts usage Standard contacts
Positive opening With conforming to EN/IEC 60947-5-1 appendix K
Operating travel 1.5 mm (NC changing electrical state)
2.6 mm (NO changing electrical state)
4.3 mm (total travel)
Apr 5, 2020
1
Operating force 3.5 N NC changing electrical state
3.8 N NO changing electrical state
Mechanical durability 10000000 cycles
Tightening torque 0.8…1.2 N.m conforming to EN 60947-1
Shape of screw head Cross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts material Silver alloy (Ag/Ni)
Short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal 10 A conforming to EN/IEC 60947-5-1
current
[Ui] rated insulation voltage 600 V (pollution degree 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage EN/IEC 60947-1 6 kV
[Ie] rated operational current 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
Electrical durability 1000000 cycles AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/
IEC 60947-5-1: appendix C
1000000 cycles AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/
IEC 60947-5-1: appendix C
1000000 cycles AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/
IEC 60947-5-1: appendix C
1000000 cycles DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to
EN/IEC 60947-5-1: appendix C
1000000 cycles DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/
IEC 60947-5-1: appendix C
Electrical reliability Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4
Device presentation Complete product
Device presentation Yes
GCR BRIDGE XB5AACUST04
Compatibility code XB5

Environment
Protective treatment TH
Ambient air temperature for storage -40…70 °C
Ambient air temperature for operation -40…70 °C
Overvoltage category Class II conforming to IEC 60536
IP degree of protection IP66 conforming to IEC 60529
IP67
IP69
IP69K
NEMA degree of protection NEMA 13
NEMA 4X
IK degree of protection IK03 conforming to IEC 50102
Standards EN/IEC 60947-1
EN/IEC 60947-5-1
CSA C22.2 No 14
EN/IEC 60947-5-4
UL 508
JIS C8201-5-1
JIS C8201-1
Product certifications RINA
UL listed
BV
CSA
GL
DNV
LROS (Lloyds register of shipping)

2
Vibration resistance 5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
Shock resistance 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Toxic heavy metal free Yes
Mercury free Yes
RoHS exemption information Yes
China RoHS Regulation China RoHS declaration
Environmental Disclosure Product Environmental Profile
Circularity Profile End of Life Information
WEEE The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins

Contractual warranty
Warranty 18 months

3
Product data sheet XB5AA41
Characteristics red projecting complete push-button Diam22
spring return 1NO unmarked

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range of product Harmony XB5
Product or component type Push-button
Device short name XB5
Bezel material Plastic
Dark grey plastic
Head type Standard
Fixing collar material Plastic
Mounting diameter 22 mm
Sale per indivisible quantity 1

Complementary
Mechanical durability 10000000 cycles
Device presentation Complete product
Device presentation Yes
GCR BRIDGE XB5AACUST03
Compatibility code XB5

Environment
Ambient air temperature for storage -40…70 °C
Ambient air temperature for operation -40…70 °C
IP degree of protection IP67
IP69
IP69K
IP66
IK degree of protection IK03

Offer Sustainability
Sustainable offer status Green Premium product

Apr 5, 2020
1
REACh Regulation REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Toxic heavy metal free Yes
Mercury free Yes
RoHS exemption information Yes
China RoHS Regulation China RoHS declaration
Environmental Disclosure Product Environmental Profile
Circularity Profile End of Life Information
WEEE The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins

2
Data sheet 6AV2124-0MC01-0AX0
SIMATIC HMI TP1200 Comfort, Comfort Panel, Touch operation, 12"
widescreen TFT display, 16 million colors, PROFINET interface,
MPI/PROFIBUS DP interface, 12 MB configuration memory,
Windows CE 6.0 (Microsoft Support included Security updates
discontinued) configurable from WinCC Comfort V11

General information
Product type designation TP1200 Comfort

Display
Design of display TFT
Screen diagonal 12.1 in
Display width 261.1 mm
Display height 163.2 mm
Number of colors 16 777 216
Resolution (pixels)
● Horizontal image resolution 1 280 Pixel
● Vertical image resolution 800 Pixel
Backlighting
● MTBF backlighting (at 25 °C) 80 000 h
● Backlight dimmable Yes; 0-100 %

Control elements
Keyboard fonts
● Function keys
— Number of function keys 0

6AV2124-0MC01-0AX0 Subject to change without notice


Page 1/10 05/28/2020 © Copyright Siemens
— Number of function keys with LEDs 0
● Keys with LED No
● System keys No
● Numeric keyboard Yes; Onscreen keyboard
● alphanumeric keyboard Yes; Onscreen keyboard
Touch operation
● Design as touch screen Yes
Expansions for operator control of the process
● DP direct LEDs (LEDs as S7 output I/O)
— F1...Fx 0
● Direct keys (keys as S7 input I/O)
— F1...Fx 0
● Direct keys (touch buttons as S7 input I/O) 40

Installation type/mounting
Mounting position vertical
Mounting in portrait format possible Yes
Mounting in landscape format possible Yes
maximum permissible angle of inclination without 35°
external ventilation

Supply voltage
Type of supply voltage DC
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V

Input current
Current consumption (rated value) 0.85 A
Starting current inrush I²t 0.5 A²·s

Power
Active power input, typ. 20 W

Processor
Processor type X86

Memory
Flash Yes
RAM Yes
Memory available for user data 12 Mbyte

Type of output
Info LED No
Power LED No
Error LED No
Acoustics

6AV2124-0MC01-0AX0 Subject to change without notice


Page 2/10 05/28/2020 © Copyright Siemens
● Buzzer No
● Speaker Yes

Time of day
Clock
● Hardware clock (real-time) Yes
● Software clock Yes
● retentive Yes; Back-up duration typically 6 weeks
● synchronizable Yes

Interfaces
Number of industrial Ethernet interfaces 1; 2 ports (switch)
Number of RS 485 interfaces 1; RS 422 / 485 combined
Number of RS 422 interfaces 0; together with RS 485
Number of RS 232 interfaces 0
Number of USB interfaces 2; USB 2.0
● USB Mini B 1; 5-pole
Number of 20 mA interfaces (TTY) 0
Number of parallel interfaces 0
Number of other interfaces 0
Number of SD card slots 2
With software interfaces No
Industrial Ethernet
● Industrial Ethernet status LED 2
● Number of ports of the integrated switch 2

Protocols
PROFINET Yes
Supports protocol for PROFINET IO Yes
IRT Yes; As of WinCC V12
PROFIBUS Yes
MPI Yes
Protocols (Ethernet)
● TCP/IP Yes
● DHCP Yes
● SNMP Yes
● DCP Yes
● LLDP Yes
WEB characteristics
● HTTP Yes
● HTTPS Yes
● HTML Yes
● XML Yes
● CSS Yes

6AV2124-0MC01-0AX0 Subject to change without notice


Page 3/10 05/28/2020 © Copyright Siemens
● Active X Yes
● JavaScript Yes
● Java VM No
Redundancy mode
Media redundancy
— MRP Yes; As of WinCC V12
Further protocols
● CAN No
● EtherNet/IP Yes
● MODBUS Yes

EMC
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes
● Limit class B, for use in residential areas No

Degree and class of protection


IP (at the front) IP65
IP (rear) IP20
NEMA (front)
● Enclosure Type 4 at the front Yes
● Enclosure Type 4x at the front Yes

Standards, approvals, certificates


CE mark Yes
cULus Yes
RCM (formerly C-TICK) Yes
KC approval Yes
Use in hazardous areas
● ATEX Zone 2 Yes
● ATEX Zone 22 Yes
● IECEx Zone 2 Yes
● IECEx Zone 22 Yes
● cULus Class I Zone 1 No
● cULus Class I Zone 2, Division 2 Yes
● FM Class I Division 2 Yes
Marine approval
● Germanischer Lloyd (GL) Yes; As of product version: 10
● American Bureau of Shipping (ABS) Yes; As of product version: 10
● Bureau Veritas (BV) Yes; As of product version: 10
● Det Norske Veritas (DNV) Yes; As of product version: 10
● Lloyds Register of Shipping (LRS) Yes; As of product version: 10
● Nippon Kaiji Kyokai (Class NK) Yes; As of product version: 10
● Polski Rejestr Statkow (PRS) No

6AV2124-0MC01-0AX0 Subject to change without notice


Page 4/10 05/28/2020 © Copyright Siemens
Ambient conditions
Ambient temperature during operation
● Operation (vertical installation)
— For vertical installation, min. 0 °C
— For vertical installation, max. 50 °C; (55 °C, see entry ID: 64847814)
● Operation (max. tilt angle)
— At maximum tilt angle, min. 0 °C
— At maximum tilt angle, min. 40 °C
● Operation (vertical installation, portrait format)
— For vertical installation, min. 0 °C
— For vertical installation, max. 40 °C
● Operation (max. tilt angle, portrait format)
— At maximum tilt angle, min. 0 °C
— At maximum tilt angle, min. 35 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 90 %; no condensation

Operating systems
proprietary No
pre-installed operating system
● Windows CE Yes

Configuration
Message indicator Yes
Alarm system (incl. buffer and acknowledgment) Yes
Process value display (output) Yes
Process value default (input) possible Yes
Recipe management Yes
Configuration software
● STEP 7 Basic (TIA Portal) No
● STEP 7 Professional (TIA Portal) No
● WinCC flexible Compact No
● WinCC flexible Standard No
● WinCC flexible Advanced No
● WinCC Basic (TIA Portal) No
● WinCC Comfort (TIA Portal) Yes; from V11
● WinCC Advanced (TIA Portal) Yes; from V11
● WinCC Professional (TIA Portal) Yes; from V11

Languages

6AV2124-0MC01-0AX0 Subject to change without notice


Page 5/10 05/28/2020 © Copyright Siemens
Online languages
● Number of online/runtime languages 32
Project languages
● Languages per project 32

Functionality under WinCC (TIA Portal)


Libraries Yes
Applications/options
● Web browser Yes
● Pocket Word Yes
● Pocket Excel Yes
● PDF Viewer Yes
● Media Player Yes
● SIMATIC WinCC Sm@rtServer Yes
● SIMATIC WinCC Audit Yes
Number of Visual Basic Scripts Yes
Task planner
● time-controlled Yes
● task-controlled Yes
Help system
● Number of characters per info text 70
Message system
● Number of alarm classes 32
● Bit messages
— Number of bit messages 4 000
● Analog messages
— Number of analog messages 200
● S7 alarm number procedure Yes
● System messages HMI Yes
● System messages, other (SIMATIC S7, Yes
Sinumerik, Simotion, etc.)
● Number of characters per message 80
● Number of process values per message 8
● Acknowledgment groups Yes
● Message indicator Yes
● Message buffer
— Number of entries 1 024
— Circulating buffer Yes
— retentive Yes
— maintenance-free Yes
Recipe management
● Number of recipes 300

6AV2124-0MC01-0AX0 Subject to change without notice


Page 6/10 05/28/2020 © Copyright Siemens
● Data records per recipe 500
● Entries per data record 1 000
● Size of internal recipe memory 2 Mbyte
● Recipe memory expandable Yes
Variables
● Number of variables per device 2 048
● Number of variables per screen 400
● Limit values Yes
● Multiplexing Yes
● Structures Yes
● Arrays Yes
Images
● Number of configurable images 500
● Permanent window/default Yes
● Global image Yes
● Pop-up images Yes
● Slide-in images Yes
● Image selection by PLC Yes
● Image number in the PLC Yes
Image objects
● Number of objects per image 400
● Text fields Yes
● I/O fields Yes
● Graphic I/O fields (graphics list) Yes
● Symbolic I/O fields (text list) Yes
● Date/time fields Yes
● Switches Yes
● Buttons Yes
● Graphic display Yes
● Icons Yes
● Geometric objects Yes
Complex image objects
● Number of complex objects per screen 20
● Alarm view Yes
● Trend view Yes
● User view Yes
● Status/control Yes
● Sm@rtClient view Yes
● Recipe view Yes
● f(x) trend view Yes
● System diagnostics view Yes

6AV2124-0MC01-0AX0 Subject to change without notice


Page 7/10 05/28/2020 © Copyright Siemens
● Media Player Yes
● HTML browser Yes
● PDF display Yes
● IP camera display Yes
● Bar graphs Yes
● Sliders Yes
● Pointer instruments Yes
● Analog/digital clock Yes
Lists
● Number of text lists per project 500
● Number of entries per text list 500
● Number of graphics lists per project 500
● Number of entries per graphics list 500
Archiving
● Number of archives per device 50
● Number of entries per archive 20 000
● Message archive Yes
● Process value archive Yes
● Archiving methods
— Sequential archive Yes
— Short-term archive Yes
● Memory location
— Memory card Yes
— USB memory Yes
— Ethernet Yes
● Data storage format
— CSV Yes
— TXT Yes
— RDB Yes
Security
● Number of user groups 50
● Number of user rights 32
● Number of users 50
● Password export/import Yes
● SIMATIC Logon Yes
Logging through printer
● Alarms Yes
● Report (shift log) Yes
● Hardcopy Yes
● Electronic print to file Yes; PDF, HTML
Character sets

6AV2124-0MC01-0AX0 Subject to change without notice


Page 8/10 05/28/2020 © Copyright Siemens
● Keyboard fonts
— US English Yes
Transfer (upload/download)
● MPI/PROFIBUS DP Yes
● USB Yes
● Ethernet Yes
● using external storage medium Yes
Process coupling
● S7-1200 Yes
● S7-1500 Yes
● S7-200 Yes
● S7-300/400 Yes
● LOGO! Yes
● WinAC Yes
● SINUMERIK Yes; with SINUMERIK option package
● SIMOTION Yes
● Allen Bradley (EtherNet/IP) Yes
● Allen Bradley (DF1) Yes
● Mitsubishi (MC TCP/IP) Yes
● Mitsubishi (FX) Yes
● OMRON (FINS TCP) No
● OMRON (LINK/Multilink) Yes
● Modicon (Modbus TCP/IP) Yes
● Modicon (Modbus) Yes
● OPC UA Client Yes
● OPC UA Server Yes
Service tools/configuration aids
● Backup/Restore manually Yes
● Backup/Restore automatically Yes
● Simulation Yes
● Device switchover Yes

Peripherals/Options
Printer Yes
SIMATIC HMI MM memory card: Multi Media Card Yes; Up to 128 MB
SIMATIC HMI SD memory card: Secure Digital Yes; Up to 2 GB
memory card
SIMATIC HMI CF memory card Compact Flash Card No
USB memory Yes
SIMATIC IPC USB Flashdrive (USB stick) Yes; Up to 16 GB
SIMATIC HMI USB stick Yes; Up to 8 GB
Network camera Yes

6AV2124-0MC01-0AX0 Subject to change without notice


Page 9/10 05/28/2020 © Copyright Siemens
Mechanics/material
Enclosure material (front)
● Plastic No
● Aluminum Yes
● Stainless steel No

Dimensions
Width of the housing front 330 mm
Height of housing front 241 mm
Mounting cutout, width 310 mm
Mounting cutout, height 221 mm
Overall depth 65 mm

Weights
Weight without packaging 2.8 kg
Weight incl. packaging 3.5 kg

last modified: 05/09/2020

6AV2124-0MC01-0AX0 Subject to change without notice


Page 10/10 05/28/2020 © Copyright Siemens
Data sheet 6ES7131-6BH00-0BA0
*** Spare part *** SIMATIC ET 200SP, digital input module, DI 16X
24 V DC Standard, suitable for BU type A0, color code CC00,
module diagnostics

General information
Product type designation DI 16x24VDC ST
Firmware version V1.1
● FW update possible Yes
usable BaseUnits BU type A0
Color code for module-specific color identification CC00
plate
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode No
Engineering with
● STEP 7 TIA Portal configurable/integrated as of V13 SP1
version
● STEP 7 configurable/integrated as of version V5.5 / -
● PCS 7 configurable/integrated as of version V8.1 SP1
● PROFIBUS as of GSD version/GSD revision GSD Revision 5
● PROFINET as of GSD version/GSD revision GSDML V2.3
Operating mode
● DI Yes

6ES7131-6BH00-0BA0 Subject to change without notice


Page 1/4 05/28/2020 © Copyright Siemens
● Counter No
● Oversampling No
● MSI No

Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes

Input current
Current consumption, max. 90 mA

Encoder supply
Short-circuit protection No
24 V encoder supply
● 24 V No
● Short-circuit protection No

Power loss
Power loss, typ. 1.7 W

Address area
Address space per module
● Address space per module, max. 2 byte; + 2 bytes for QI information

Hardware configuration
Automatic encoding
● Mechanical coding element Yes
Selection of BaseUnit for connection variants
● 1-wire connection BU type A0
● 2-wire connection BU type A0 + external terminals
● 3-wire connection BU type A0 + external terminals
● 4-wire connection BU type A0 + external terminals

Digital inputs
Number of digital inputs 16
Source/sink input P-reading
Input characteristic curve in accordance with IEC Yes
61131, type 1
Input characteristic curve in accordance with IEC No
61131, type 2
Input characteristic curve in accordance with IEC Yes
61131, type 3
Pulse extension No
Input voltage
● Rated value (DC) 24 V

6ES7131-6BH00-0BA0 Subject to change without notice


Page 2/4 05/28/2020 © Copyright Siemens
● for signal "0" -30 to +5 V
● for signal "1" +11 to +30V
Input current
● for signal "1", typ. 2.5 mA
Input delay (for rated value of input voltage)
for standard inputs
— parameterizable Yes; 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms (in each case +
delay of 30 to 500 µs, depending on line length)
— at "0" to "1", min. 0.05 ms
— at "0" to "1", max. 20 ms
— at "1" to "0", min. 0.05 ms
— at "1" to "0", max. 20 ms
for interrupt inputs
— parameterizable No
for technological functions
— parameterizable No
Cable length
● shielded, max. 1 000 m
● unshielded, max. 600 m

Encoder
Connectable encoders
● 2-wire sensor Yes
— permissible quiescent current (2-wire 1.5 mA
sensor), max.

Interrupts/diagnostics/status information
Diagnostics function Yes
Alarms
● Diagnostic alarm Yes
Diagnostic messages
● Diagnostic information readable Yes
● Monitoring the supply voltage Yes
— parameterizable Yes
● Monitoring of encoder power supply No
● Wire-break Yes; Module-by-module, optional protective circuit for preventing
wire-break diagnostics in the case of simple encoder contacts: 25
kOhm to 45 kOhm
● Short-circuit No
● Group error Yes
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED
● Channel status display Yes; green LED
● for channel diagnostics No

6ES7131-6BH00-0BA0 Subject to change without notice


Page 3/4 05/28/2020 © Copyright Siemens
● for module diagnostics Yes; green/red DIAG LED

Potential separation
Potential separation channels
● between the channels No
● between the channels and backplane bus Yes
● between the channels and the power supply of No
the electronics

Isolation
Isolation tested with 707 V DC (type test)

Standards, approvals, certificates


Suitable for safety functions No

Dimensions
Width 15 mm
Height 73 mm
Depth 58 mm

Weights
Weight, approx. 28 g

last modified: 05/26/2020

6ES7131-6BH00-0BA0 Subject to change without notice


Page 4/4 05/28/2020 © Copyright Siemens
Data sheet 6ES7132-6BH00-0BA0
*** Spare part *** SIMATIC ET 200SP, digital output module, DQ 16x
24VDC/0.5A Standard, suitable for BU type A0, Color code CC00,
module diagnostics

General information
Product type designation DQ 16x24 VDC/0.5 A ST
Firmware version V1.0
● FW update possible Yes
usable BaseUnits BU type A0
Color code for module-specific color identification CC00
plate
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode No
Engineering with
● STEP 7 TIA Portal configurable/integrated as of V11 SP2 / V13
version
● STEP 7 configurable/integrated as of version V5.5 SP3 / -
● PCS 7 configurable/integrated as of version V8.1 SP1
● PROFIBUS as of GSD version/GSD revision GSD Revision 5
● PROFINET as of GSD version/GSD revision GSDML V2.3
Operating mode
● DQ Yes

6ES7132-6BH00-0BA0 Subject to change without notice


Page 1/5 05/28/2020 © Copyright Siemens
● DQ with energy-saving function No
● PWM No
● Oversampling No
● MSO No
Redundancy
● Redundancy capability Yes

Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes

Input current
Current consumption, max. 60 mA; without load

Output voltage
Rated value (DC) 24 V

Power loss
Power loss, typ. 1 W

Address area
Address space per module
● Address space per module, max. 2 byte

Hardware configuration
Automatic encoding
● Mechanical coding element Yes
Selection of BaseUnit for connection variants
● 1-wire connection BU type A0
● 2-wire connection BU type A0 + Potential isolation module
● 3-wire connection BU type A0 + Potential isolation module
● 4-wire connection BU type A0 + Potential isolation module

Digital outputs
Type of digital output Source output (PNP, current-sourcing)
Number of digital outputs 16
Current-sinking No
Current-sourcing Yes
Digital outputs, parameterizable Yes
Short-circuit protection Yes
● Response threshold, typ. 0.7 to 1.3 A
Limitation of inductive shutdown voltage to Typ. L+ (-50 V)
Controlling a digital input Yes
Switching capacity of the outputs
● with resistive load, max. 0.5 A

6ES7132-6BH00-0BA0 Subject to change without notice


Page 2/5 05/28/2020 © Copyright Siemens
● on lamp load, max. 5 W
Load resistance range
● lower limit 48 Ω
● upper limit 12 kΩ
Output current
● for signal "1" rated value 0.5 A
● for signal "0" residual current, max. 0.1 mA
Output delay with resistive load
● "0" to "1", typ. 50 µs
● "1" to "0", typ. 100 µs
Parallel switching of two outputs
● for uprating No
● for redundant control of a load Yes
Switching frequency
● with resistive load, max. 100 Hz
● with inductive load, max. 2 Hz
● on lamp load, max. 10 Hz
Total current of the outputs
● Current per channel, max. 0.5 A
● Current per module, max. 8 A
Total current of the outputs (per module)
horizontal installation
— up to 30 °C, max. 8 A
— up to 40 °C, max. 8 A
— up to 50 °C, max. 6 A
— up to 60 °C, max. 4 A
vertical installation
— up to 30 °C, max. 8 A
— up to 40 °C, max. 6 A
— up to 50 °C, max. 4 A
— up to 60 °C, max. 4 A
Cable length
● shielded, max. 1 000 m
● unshielded, max. 600 m

Interrupts/diagnostics/status information
Diagnostics function Yes
Substitute values connectable Yes
Alarms
● Diagnostic alarm Yes
Diagnostic messages
● Monitoring the supply voltage Yes

6ES7132-6BH00-0BA0 Subject to change without notice


Page 3/5 05/28/2020 © Copyright Siemens
● Wire-break Yes; Module-wise
● Short-circuit to M Yes; Module-wise
● Short-circuit to L+ Yes; Module-wise
● Group error Yes
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED
● Channel status display Yes; green LED
● for channel diagnostics No
● for module diagnostics Yes; green/red DIAG LED

Potential separation
Potential separation channels
● between the channels No
● between the channels and backplane bus Yes
● between the channels and the power supply of No
the electronics

Isolation
Isolation tested with 707 V DC (type test)

Standards, approvals, certificates


Suitable for safety functions No
Suitable for safety-related tripping of standard Yes; From FS03
modules
Highest safety class achievable in safety mode
● Performance level according to ISO 13849-1 PL d
● SIL acc. to IEC 61508 SIL 2

Ambient conditions
Ambient temperature during operation
● horizontal installation, min. 0 °C
● horizontal installation, max. 60 °C
● vertical installation, min. 0 °C; in all other mounting positions
● vertical installation, max. 50 °C; in all other mounting positions
Altitude during operation relating to sea level
● Ambient air temperature-barometric pressure- On request: Negative ambient temperature down to -30 °C
altitude (without condensation), installation altitudes between 2 000 m and
5 000 m

Dimensions
Width 15 mm
Height 73 mm
Depth 58 mm

Weights
Weight, approx. 28 g

6ES7132-6BH00-0BA0 Subject to change without notice


Page 4/5 05/28/2020 © Copyright Siemens
last modified: 05/09/2020

6ES7132-6BH00-0BA0 Subject to change without notice


Page 5/5 05/28/2020 © Copyright Siemens
Data sheet 6ES7134-6GD00-0BA1
*** Spare part *** SIMATIC ET 200SP, analog input module, AI 4XI
2-/4-wire standard, suitable for BU type A0, A1, Color code CC03,
Module diagnostics, 16 bit, +/-0.3%

General information
Product type designation AI 4xI 2-/4-wire ST
Firmware version V1.1
● FW update possible Yes
usable BaseUnits BU type A0, A1
Color code for module-specific color identification CC03
plate
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode No
● Measuring range scalable No
Engineering with
● STEP 7 TIA Portal configurable/integrated as of V11 SP2 / V13
version
● STEP 7 configurable/integrated as of version V5.5 SP3 / -
● PCS 7 configurable/integrated as of version V8.1 SP1
● PROFIBUS as of GSD version/GSD revision GSD Revision 5
● PROFINET as of GSD version/GSD revision GSDML V2.3
Operating mode

6ES7134-6GD00-0BA1 Subject to change without notice


Page 1/4 05/28/2020 © Copyright Siemens
● Oversampling No
● MSI No

CiR – Configuration in RUN


Reparameterization possible in RUN Yes
Calibration possible in RUN No

Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes

Input current
Current consumption, max. 37 mA; without sensor supply

Encoder supply
24 V encoder supply
● 24 V Yes
● Short-circuit protection Yes
● Output current, max. 20 mA; max. 50 mA per channel for a duration < 10 s

Power loss
Power loss, typ. 0.85 W; Without encoder supply voltage

Address area
Address space per module
● Address space per module, max. 8 byte; + 1 byte for QI information

Analog inputs
Number of analog inputs 4; Differential inputs
● For current measurement 4
permissible input current for current input (destruction 50 mA
limit), max.
Cycle time (all channels), min. Sum of the basic conversion times and additional processing
times (depending on the parameterization of the active channels)
Input ranges (rated values), currents
● 0 to 20 mA Yes
— Input resistance (0 to 20 mA) 100 Ω; + approx. 0.7 V diode forward voltage in 2-wire operation
● -20 mA to +20 mA Yes
— Input resistance (-20 mA to +20 mA) 100 Ω
● 4 mA to 20 mA Yes
— Input resistance (4 mA to 20 mA) 100 Ω; + approx. 0.7 V diode forward voltage in 2-wire operation
Cable length
● shielded, max. 1 000 m

Analog value generation for the inputs

6ES7134-6GD00-0BA1 Subject to change without notice


Page 2/4 05/28/2020 © Copyright Siemens
Measurement principle integrating (Sigma-Delta)
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), 16 bit
max.
● Integration time, parameterizable Yes
● Interference voltage suppression for 16.6 / 50 / 60 Hz
interference frequency f1 in Hz
● Conversion time (per channel) 180 / 60 / 50 ms
Smoothing of measured values
● Number of smoothing levels 4; None; 4/8/16 times
● parameterizable Yes

Encoder
Connection of signal encoders
● for voltage measurement No
● for current measurement as 2-wire transducer Yes
— Burden of 2-wire transmitter, max. 650 Ω
● for current measurement as 4-wire transducer Yes

Errors/accuracies
Linearity error (relative to input range), (+/-) 0.01 %
Temperature error (relative to input range), (+/-) 0.005 %/K
Crosstalk between the inputs, min. 50 dB; Applies to up to ±5 V overvoltage in other channels
Repeat accuracy in steady state at 25 °C (relative to 0.05 %
input range), (+/-)
Operational error limit in overall temperature range
● Current, relative to input range, (+/-) 0.5 %
Basic error limit (operational limit at 25 °C)
● Current, relative to input range, (+/-) 0.3 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of 70 dB
interference < rated value of input range), min.
● Common mode voltage, max. 10 V
● Common mode interference, min. 90 dB

Interrupts/diagnostics/status information
Diagnostics function Yes
Alarms
● Diagnostic alarm Yes
● Limit value alarm No
Diagnostic messages
● Monitoring the supply voltage Yes
● Wire-break Yes; at 4 to 20 mA
● Short-circuit Yes; 2-wire mode: Short-circuit of the encoder supply to ground or
of an input to the encoder supply

6ES7134-6GD00-0BA1 Subject to change without notice


Page 3/4 05/28/2020 © Copyright Siemens
● Group error Yes
● Overflow/underflow Yes
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED) Yes; green LED
● Channel status display Yes; green LED
● for channel diagnostics No
● for module diagnostics Yes; green/red LED

Potential separation
Potential separation channels
● between the channels Yes; channel group-specific between 2-wire current input group
and 4-wire voltage input group
● between the channels and backplane bus Yes
● between the channels and the power supply of Yes; only for 4-wire transducer
the electronics

Permissible potential difference


between the inputs (UCM) 10 V DC

Isolation
Isolation tested with 707 V DC (type test)

Dimensions
Width 15 mm
Height 73 mm
Depth 58 mm

Weights
Weight, approx. 31 g

last modified: 05/26/2020

6ES7134-6GD00-0BA1 Subject to change without notice


Page 4/4 05/28/2020 © Copyright Siemens
Data sheet 6ES7214-1HG40-0XB0
SIMATIC S7-1200, CPU 1214C, compact CPU, DC/DC/relay,
onboard I/O: 14 DI 24 V DC; 10 DO relay 2 A; 2 AI 0-10 V DC, Power
supply: DC 20.4-28.8V DC, Program/data memory 100 KB

General information
Product type designation CPU 1214C DC/DC/relay
Firmware version V4.2
Engineering with
● Programming package STEP 7 V14 or higher

Supply voltage
Rated value (DC)
● 24 V DC Yes
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Load voltage L+
● Rated value (DC) 24 V
● permissible range, lower limit (DC) 20.4 V
● permissible range, upper limit (DC) 28.8 V

Input current
Current consumption (rated value) 500 mA; CPU only
Current consumption, max. 1 500 mA; CPU with all expansion modules

6ES7214-1HG40-0XB0 Subject to change without notice


Page 1/9 05/28/2020 © Copyright Siemens
Inrush current, max. 12 A; at 28.8 V
I²t 0.8 A²·s

Output current
for backplane bus (5 V DC), max. 1 600 mA; Max. 5 V DC for SM and CM

Encoder supply
24 V encoder supply
● 24 V L+ minus 4 V DC min.

Power loss
Power loss, typ. 12 W

Memory
Work memory
● integrated 100 kbyte
● expandable No
Load memory
● integrated 4 Mbyte
● Plug-in (SIMATIC Memory Card), max. with SIMATIC memory card
Backup
● present Yes
● maintenance-free Yes
● without battery Yes

CPU processing times


for bit operations, typ. 0.08 µs; / instruction
for word operations, typ. 1.7 µs; / instruction
for floating point arithmetic, typ. 2.3 µs; / instruction

CPU-blocks
Number of blocks (total) DBs, FCs, FBs, counters and timers. The maximum number of
addressable blocks ranges from 1 to 65535. There is no
restriction, the entire working memory can be used
OB
● Number, max. Limited only by RAM for code

Data areas and their retentivity


Retentive data area (incl. timers, counters, flags), 10 kbyte
max.
Flag
● Number, max. 8 kbyte; Size of bit memory address area
Local data
● per priority class, max. 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2
to 26: 6 KB

Address area
Process image

6ES7214-1HG40-0XB0 Subject to change without notice


Page 2/9 05/28/2020 © Copyright Siemens
● Inputs, adjustable 1 kbyte
● Outputs, adjustable 1 kbyte

Hardware configuration
Number of modules per system, max. 3 comm. modules, 1 signal board, 8 signal modules

Time of day
Clock
● Hardware clock (real-time) Yes
● Backup time 480 h; Typical
● Deviation per day, max. ±60 s/month at 25 °C

Digital inputs
Number of digital inputs 14; Integrated
● of which inputs usable for technological 6; HSC (High Speed Counting)
functions
Source/sink input Yes
Number of simultaneously controllable inputs
all mounting positions
— up to 40 °C, max. 14
Input voltage
● Rated value (DC) 24 V
● for signal "0" 5 V DC at 1 mA
● for signal "1" 15 V DC at 2.5 mA
Input delay (for rated value of input voltage)
for standard inputs
— parameterizable 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms,
selectable in groups of four
— at "0" to "1", min. 0.2 ms
— at "0" to "1", max. 12.8 ms
for interrupt inputs
— parameterizable Yes
for technological functions
— parameterizable Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80
kHz & 3 @ 30 kHz
Cable length
● shielded, max. 500 m; 50 m for technological functions
● unshielded, max. 300 m; for technological functions: No

Digital outputs
Number of digital outputs 10; Relays
Switching capacity of the outputs
● with resistive load, max. 2 A
● on lamp load, max. 30 W with DC, 200 W with AC
Output delay with resistive load

6ES7214-1HG40-0XB0 Subject to change without notice


Page 3/9 05/28/2020 © Copyright Siemens
● "0" to "1", max. 10 ms; max.
● "1" to "0", max. 10 ms; max.
Relay outputs
● Number of relay outputs 10
● Number of operating cycles, max. mechanically 10 million, at rated load voltage 100 000
Cable length
● shielded, max. 500 m
● unshielded, max. 150 m

Analog inputs
Number of analog inputs 2
Input ranges
● Voltage Yes
Input ranges (rated values), voltages
● 0 to +10 V Yes
— Input resistance (0 to 10 V) ≥100k ohms
Cable length
● shielded, max. 100 m; twisted and shielded

Analog outputs
Number of analog outputs 0

Analog value generation for the inputs


Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), 10 bit
max.
● Integration time, parameterizable Yes
● Conversion time (per channel) 625 µs

Encoder
Connectable encoders
● 2-wire sensor Yes

1. Interface
Interface type PROFINET
Physics Ethernet
Isolated Yes
automatic detection of transmission rate Yes
Autonegotiation Yes
Autocrossing Yes
Interface types
● Number of ports 1
● integrated switch No
Protocols
● PROFINET IO Controller Yes

6ES7214-1HG40-0XB0 Subject to change without notice


Page 4/9 05/28/2020 © Copyright Siemens
● PROFINET IO Device Yes
● SIMATIC communication Yes
● Open IE communication Yes
● Web server Yes
● Media redundancy No
PROFINET IO Controller
● Transmission rate, max. 100 Mbit/s
Services
— PG/OP communication Yes
— S7 routing Yes
— Isochronous mode No
— IRT No
— MRP No
— MRPD No
— PROFIenergy No
— Prioritized startup Yes
— Number of IO devices with prioritized 16
startup, max.
— Number of connectable IO Devices, max. 16
— Number of connectable IO Devices for RT, 16
max.
— of which in line, max. 16
— Activation/deactivation of IO Devices Yes
— Number of IO Devices that can be 8
simultaneously activated/deactivated, max.
— Updating time The minimum value of the update time also depends on the
communication component set for PROFINET IO, on the number
of IO devices and the quantity of configured user data.
PROFINET IO Device
Services
— PG/OP communication Yes
— S7 routing Yes
— Isochronous mode No
— IRT No
— MRP No
— MRPD No
— PROFIenergy Yes
— Shared device Yes
— Number of IO Controllers with shared 2
device, max.

Protocols
Supports protocol for PROFINET IO Yes

6ES7214-1HG40-0XB0 Subject to change without notice


Page 5/9 05/28/2020 © Copyright Siemens
PROFIBUS Yes; CM 1243-5 (master) or CM 1242-5 (slave) required
AS-Interface Yes; CM 1243-2 required
Protocols (Ethernet)
● TCP/IP Yes
● DHCP No
● SNMP Yes
● DCP Yes
● LLDP Yes
Open IE communication
● TCP/IP Yes
— Data length, max. 8 kbyte
● ISO-on-TCP (RFC1006) Yes
— Data length, max. 8 kbyte
● UDP Yes
— Data length, max. 1 472 byte
Web server
● supported Yes
● User-defined websites Yes
Further protocols
● MODBUS Yes

Communication functions
S7 communication
● supported Yes
● as server Yes
● as client Yes
● User data per job, max. See online help (S7 communication, user data size)
Number of connections
● overall 16; dynamically

Test commissioning functions


Status/control
● Status/control variable Yes
● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers,
counters
Forcing
● Forcing Yes
Diagnostic buffer
● present Yes
Traces
● Number of configurable Traces 2
● Memory size per trace, max. 512 kbyte

Interrupts/diagnostics/status information

6ES7214-1HG40-0XB0 Subject to change without notice


Page 6/9 05/28/2020 © Copyright Siemens
Diagnostics indication LED
● RUN/STOP LED Yes
● ERROR LED Yes
● MAINT LED Yes

Integrated Functions
Number of counters 6
Counting frequency (counter) max. 100 kHz
Frequency measurement Yes
controlled positioning Yes
Number of position-controlled positioning axes, max. 8
Number of positioning axes via pulse-direction Up to 4 with SB 1222
interface
PID controller Yes
Number of alarm inputs 4

Potential separation
Potential separation digital inputs
● Potential separation digital inputs 500V AC for 1 minute
● between the channels, in groups of 1
Potential separation digital outputs
● Potential separation digital outputs Relays
● between the channels No
● between the channels, in groups of 2

EMC
Interference immunity against discharge of static electricity
● Interference immunity against discharge of Yes
static electricity acc. to IEC 61000-4-2
— Test voltage at air discharge 8 kV
— Test voltage at contact discharge 6 kV
Interference immunity to cable-borne interference
● Interference immunity on supply lines acc. to Yes
IEC 61000-4-4
● Interference immunity on signal cables acc. to Yes
IEC 61000-4-4
Interference immunity against voltage surge
● Interference immunity on supply lines acc. to Yes
IEC 61000-4-5
Interference immunity against conducted variable disturbance induced by high-frequency fields
● Interference immunity against high-frequency Yes
radiation acc. to IEC 61000-4-6
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes; Group 1

6ES7214-1HG40-0XB0 Subject to change without notice


Page 7/9 05/28/2020 © Copyright Siemens
● Limit class B, for use in residential areas Yes; When appropriate measures are used to ensure compliance
with the limits for Class B according to EN 55011

Degree and class of protection


IP degree of protection IP20

Standards, approvals, certificates


CE mark Yes
UL approval Yes
cULus Yes
FM approval Yes
RCM (formerly C-TICK) Yes
KC approval Yes
Marine approval Yes

Ambient conditions
Free fall
● Fall height, max. 0.3 m; five times, in product package
Ambient temperature during operation
● min. -20 °C
● max. 60 °C; Number of simultaneously activated inputs or outputs 7 or
5 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 14 or
10 at 55 °C horizontal or 45 °C vertical
● horizontal installation, min. -20 °C
● horizontal installation, max. 60 °C
● vertical installation, min. -20 °C
● vertical installation, max. 50 °C
Ambient temperature during storage/transportation
● min. -40 °C
● max. 70 °C
Air pressure acc. to IEC 60068-2-13
● Operation, min. 795 hPa
● Operation, max. 1 080 hPa
● Storage/transport, min. 660 hPa
● Storage/transport, max. 1 080 hPa
Altitude during operation relating to sea level
● Installation altitude, min. -1 000 m
● Installation altitude, max. 2 000 m
Relative humidity
● Operation, max. 95 %; no condensation
Vibrations
● Vibration resistance during operation acc. to 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail
IEC 60068-2-6
● Operation, tested according to IEC 60068-2-6 Yes
Shock testing

6ES7214-1HG40-0XB0 Subject to change without notice


Page 8/9 05/28/2020 © Copyright Siemens
● tested according to IEC 60068-2-27 Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak
value), duration 11 ms
Pollutant concentrations
● SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free

Configuration
Programming
Programming language
— LAD Yes
— FBD Yes
— SCL Yes
Know-how protection
● User program protection/password protection Yes
● Copy protection Yes
● Block protection Yes
Access protection
● Protection level: Write protection Yes
● Protection level: Read/write protection Yes
● Protection level: Complete protection Yes
Cycle time monitoring
● adjustable Yes

Dimensions
Width 110 mm
Height 100 mm
Depth 75 mm

Weights
Weight, approx. 435 g

last modified: 05/09/2020

6ES7214-1HG40-0XB0 Subject to change without notice


Page 9/9 05/28/2020 © Copyright Siemens
Product data sheet METSEPM5330
Characteristics

Main
Range PowerLogic

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Product name PowerLogic PM5000
Device short name PM5330
Product or component type Power meter

Complementary
Power quality analysis Up to the 31st harmonic
Device application Power monitoring

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Multi-tariff

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Type of measurement Current
Voltage
Frequency
Power factor
Energy
Active and reactive power
[Us] rated supply voltage 100...415 V AC 45...65 Hz
125...250 V DC
Network frequency 50 Hz
60 Hz
[In] rated current 1 A
5 A
Poles description 3P + N
3P
1P + N
Maximum power consumption in VA 10 VA at 415 V
Ride-through time 80 Ms 120 V AC typical
100 Ms 230 V AC typical
100 Ms 415 V AC typical
Display type Backlit LCD
Display resolution 128 x 128 pixels
Sampling rate 64 samples/cycle
Measurement current 10…9000 MA
Analogue input type Voltage (impedance 5 MOhm)
Current (impedance 0.3 MOhm)
Measurement voltage 35…690 V AC 45...65 Hz between phases
20…400 V AC 45...65 Hz between phase and neutral
Frequency measurement range 45…65 Hz
Number of inputs 2 digital

May 21, 2020


1
Measurement accuracy Active energy +/- 0.5 %
Reactive energy +/- 2 %
Active power +/- 0.5 %
Apparent power +/- 0.5 %
Frequency +/- 0.05 %
Power factor +/- 0.005 %
Current +/- 0.5 %
Voltage +/- 0.5 %
Accuracy class Class 0.5S active energy conforming to IEC 62053-22
Number of outputs 2 relay
2 digital
Information displayed Tariff (4)
Communication port protocol Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd-
or none - 2 wires, insulation 2500 V
JBUS
Communication port support RS485
Data recording Maintenance logs
Time stamping
Alarm logs
Data logs
Min/Max of instantaneous values
Event logs
Memory capacity 256 kB
Connections - terminals Voltage circuit: screw terminal block4
Control circuit: screw terminal block2
Current transformer: screw terminal block6
Input/Output circuit: screw terminal block6
Relay output: screw terminal block4
Ethernet network: RJ45 connector
Mounting mode Flush-mounted
Mounting support Framework
Standards UL 61010-1
IEC 62053-22
IEC 61557-12
EN 50470-3
IEC 60529
IEC 62053-24
EN 50470-1
Product certifications CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
Width 96 Mm
Depth 72 Mm
Height 96 Mm
Net weight 430 G

Environment
Electromagnetic compatibility Limits for harmonic current emissions class A conforming to IEC 61000-3-2
Electrostatic discharge level 4 conforming to IEC 61000-4-2
Conducted RF disturbances level 3 conforming to IEC 61000-4-6
Magnetic field at power frequency level 4 conforming to IEC 61000-4-8
Conducted and radiated emissions class B conforming to EN 55022
IP degree of protection IP52 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529
Relative humidity 5…95 % at 50 °C
Pollution degree 2
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Operating altitude 2000 m

Offer Sustainability
Sustainable offer status Green Premium product
REACh free of SVHC Yes
EU RoHS Directive
Compliant EU RoHS Declaration
Mercury free Yes
RoHS exemption information
Yes

2
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Product Life Status : Commercialised

3
Product data sheet RXM4AB1BD
Characteristics

Main
Range of product Zelio Relay

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Series name Miniature
Product or component type Plug-in relay
Device short name RXM
Contacts type and composition 4 C/O
[Uc] control circuit voltage 24 V DC
[Ithe] conventional enclosed thermal current 6 A at -40…55 °C
Status LED Without

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Control type Lockable test button

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Utilisation coefficient 20 %

Complementary
Shape of pin Flat
[Ui] rated insulation voltage 250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
[Uimp] rated impulse withstand voltage 2.5 KV during 1.2/50 µs
Contacts material AgNi
[Ie] rated operational current 3 A at 28 V (DC) NC conforming to IEC
3 A at 250 V (AC) NC conforming to IEC
6 A at 28 V (DC) NO conforming to IEC
6 A at 250 V (AC) NO conforming to IEC
6 A at 277 V (AC) conforming to UL
8 A at 30 V (DC) conforming to UL
Maximum switching voltage 250 V conforming to IEC
Load current 6 A at 250 V AC
6 A at 28 V DC
Maximum switching capacity 1500 VA/168 W
Minimum switching capacity 170 mW at 10 mA, 17 V
Operating rate <= 1200 cycles/hour under load
<= 18000 cycles/hour no-load
Mechanical durability 10000000 Cycles
Electrical durability 100000 Cycles for resistive load
Average coil consumption 0.9 W
Drop-out voltage threshold >= 0.1 Uc
Operating time 20 ms
Reset time 20 Ms
Average resistance 650 Ohm at 20 °C +/- 10 %
Rated operational voltage limits 19.2...26.4 V DC
Safety reliability data B10d = 100000

Feb 13, 2020


1
Protection category RT I
Test levels Level A group mounting
Operating position Any position
CAD overall height 79 Mm
CAD overall depth 78.45 Mm
Net weight 0.037 Kg
Device presentation Complete product

Environment
Dielectric strength 1300 V AC between contacts with micro disconnection
2000 V AC between coil and contact with reinforced
2000 V AC between poles with basic
Product certifications UL
CE
GOST
REACH
CSA
RoHS
Lloyd's
Standards UL 508
EN/IEC 61810-1
CSA C22.2 No 14
Ambient air temperature for storage -40…85 °C
Ambient air temperature for operation -40…55 °C
Vibration resistance 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating
IP degree of protection IP40 conforming to EN/IEC 60529
Shock resistance 10 gn for in operation
30 gn for not operating
Pollution degree 2

Offer Sustainability
Sustainable offer status Green Premium product
REACh free of SVHC Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Decla-
ration
Toxic heavy metal free Yes
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile No need of specific recycling operations
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised

2
Product data sheet XB5AVG3
Characteristics

Main
Range of product Harmony XB5

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Product or component type Pilot light
Device short name XB5
Bezel material Dark grey plastic
Fixing collar material Plastic
Head type Standard
Mounting diameter 22 Mm
Sale per indivisible quantity 1

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Shape of signaling unit head Round

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Cap/operator or lens colour Green
Operator additional information With plain lens
Light source Protected LED
Bulb base Integral LED
Light source colour Green
[Us] rated supply voltage 110...120 V AC at 50/60 Hz
Device presentation Complete product

Complementary
Height 42 Mm
Width 30 Mm
Depth 54 Mm
Terminals description ISO n°1 (X1-X2)PL
Net weight 0.038 Kg
Resistance to high pressure washer 7000000 Pa at 55 °C, distance : 0.1 m
Connections - terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming-
to EN/IEC 60947-1
Screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end conforming-
to EN/IEC 60947-1
[Ui] rated insulation voltage 250 V (pollution degree 3) conforming to EN 60947-1
[Uimp] rated impulse withstand voltage 4 KV EN 60947-1
Signalling type Steady
GCR BRIDGE XB5AVCUST04
Compatibility code XB5
Supply voltage limits 100…132 V AC
Current consumption 14 mA
Service life 100000 H at rated voltage and 25 °C
Surge withstand 1 KV conforming to IEC 61000-4-5

Apr 5, 2020
1
Environment
Protective treatment TH
Ambient air temperature for storage -40…70 °C
Ambient air temperature for operation -40…70 °C
Overvoltage category Class II conforming to IEC 60536
IP degree of protection IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IP69 conforming to IEC 60529
IP69K conforming to ISO 20653
NEMA degree of protection NEMA 13
NEMA 4X
IK degree of protection IK05 conforming to IEC 50102
Standards UL 508
EN/IEC 60947-1
CSA C22.2 No 14
JIS C8201-5-1
EN/IEC 60947-5-1
EN/IEC 60947-5-4
JIS C8201-1
Product certifications CSA
UL listed
Vibration resistance 5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6
Shock resistance 50 gn (duration = 18 ms) for half sine wave acceleration conforming-
to IEC 60068-2-27
30 gn (duration = 11 ms) for half sine wave acceleration conforming-
to IEC 60068-2-27
Resistance to fast transients 2 KV conforming to IEC 61000-4-4
Resistance to electromagnetic fields 10 V/M conforming to IEC 61000-4-3
Electromagnetic compatibility Electrostatic discharge - test level: 6 kV (on contact (on metal parts)) conforming-
to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV (in free air (in insulating parts)) conform-
ing to IEC 61000-4-2
Electromagnetic emission class B conforming to IEC 55011
Resistance to electrostatic discharge 6 KV on contact (on metal parts) conforming to IEC 61000-4-2
8 KV in free air (in insulating parts) conforming to IEC 61000-4-2
Electromagnetic emission Class B conforming to IEC 55011

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Decla-
ration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised

2
Product data sheet XB5AVG4
Characteristics

Main
Range of product Harmony XB5

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Product or component type Pilot light
Device short name XB5
Bezel material Dark grey plastic
Fixing collar material Plastic
Head type Standard
Mounting diameter 22 Mm
Sale per indivisible quantity 1

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Shape of signaling unit head Round

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Cap/operator or lens colour Red
Operator additional information With plain lens
Light source Protected LED
Bulb base Integral LED
Light source colour Red
[Us] rated supply voltage 110...120 V AC at 50/60 Hz
Device presentation Complete product

Complementary
Height 42 Mm
Width 30 Mm
Depth 54 Mm
Terminals description ISO n°1 (X1-X2)PL
Net weight 0.038 Kg
Resistance to high pressure washer 7000000 Pa at 55 °C, distance : 0.1 m
Connections - terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming-
to EN/IEC 60947-1
Screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end conforming-
to EN/IEC 60947-1
[Ui] rated insulation voltage 250 V (pollution degree 3) conforming to EN 60947-1
[Uimp] rated impulse withstand voltage EN 60947-1 4 kV
Signalling type Steady
GCR BRIDGE XB5AVCUST04
Compatibility code XB5
Supply voltage limits 100…132 V AC
Current consumption 14 mA
Service life 100000 H at rated voltage and 25 °C
Surge withstand 1 KV conforming to IEC 61000-4-5

Apr 5, 2020
1
Environment
Protective treatment TH
Ambient air temperature for storage -40…70 °C
Ambient air temperature for operation -40…70 °C
Overvoltage category Class II conforming to IEC 60536
IP degree of protection IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IP69 conforming to IEC 60529
IP69K conforming to ISO 20653
NEMA degree of protection NEMA 13
NEMA 4X
IK degree of protection IK05 conforming to IEC 50102
Standards EN/IEC 60947-1
EN/IEC 60947-5-1
UL 508
EN/IEC 60947-5-4
JIS C8201-5-1
CSA C22.2 No 14
JIS C8201-1
Product certifications UL listed
CSA
Vibration resistance 5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6
Shock resistance 50 gn (duration = 18 ms) for half sine wave acceleration conforming-
to IEC 60068-2-27
30 gn (duration = 11 ms) for half sine wave acceleration conforming-
to IEC 60068-2-27
Resistance to fast transients 2 KV conforming to IEC 61000-4-4
Resistance to electromagnetic fields 10 V/M conforming to IEC 61000-4-3
Electromagnetic compatibility Electrostatic discharge - test level: 6 kV (on contact (on metal parts)) conforming-
to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV (in free air (in insulating parts)) conform-
ing to IEC 61000-4-2
Electromagnetic emission class B conforming to IEC 55011
Resistance to electrostatic discharge 6 KV on contact (on metal parts) conforming to IEC 61000-4-2
8 KV in free air (in insulating parts) conforming to IEC 61000-4-2
Electromagnetic emission Class B conforming to IEC 55011

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Decla-
ration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised

2
Product data sheet XB5AVG5
Characteristics

Main
Range of product Harmony XB5

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Product or component type Pilot light
Device short name XB5
Bezel material Dark grey plastic
Fixing collar material Plastic
Head type Standard
Mounting diameter 22 Mm
Sale per indivisible quantity 1

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Shape of signaling unit head Round

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Cap/operator or lens colour Orange
Operator additional information With plain lens
Light source Protected LED
Bulb base Integral LED
Light source colour Orange
[Us] rated supply voltage 110...120 V AC at 50/60 Hz
Device presentation Complete product

Complementary
Height 42 Mm
Width 30 Mm
Depth 54 Mm
Terminals description ISO n°1 (X1-X2)PL
Net weight 0.038 Kg
Resistance to high pressure washer 7000000 Pa at 55 °C, distance : 0.1 m
Connections - terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming-
to EN/IEC 60947-1
Screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end conforming-
to EN/IEC 60947-1
[Ui] rated insulation voltage 250 V (pollution degree 3) conforming to EN 60947-1
[Uimp] rated impulse withstand voltage 4 KV EN 60947-1
Signalling type Steady
GCR BRIDGE XB5AVCUST04
Compatibility code XB5
Supply voltage limits 100…132 V AC
Current consumption 14 mA
Service life 100000 H at rated voltage and 25 °C
Surge withstand 1 KV conforming to IEC 61000-4-5

Apr 5, 2020
1
Environment
Protective treatment TH
Ambient air temperature for storage -40…70 °C
Ambient air temperature for operation -40…70 °C
Overvoltage category Class II conforming to IEC 60536
IP degree of protection IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IP69 conforming to IEC 60529
IP69K conforming to ISO 20653
NEMA degree of protection NEMA 13
NEMA 4X
IK degree of protection IK05 conforming to IEC 50102
Standards CSA C22.2 No 14
UL 508
EN/IEC 60947-5-1
JIS C8201-5-1
EN/IEC 60947-1
EN/IEC 60947-5-4
JIS C8201-1
Product certifications CSA
UL listed
Vibration resistance 5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6
Shock resistance 50 gn (duration = 18 ms) for half sine wave acceleration conforming-
to IEC 60068-2-27
30 gn (duration = 11 ms) for half sine wave acceleration conforming-
to IEC 60068-2-27
Resistance to fast transients 2 KV conforming to IEC 61000-4-4
Resistance to electromagnetic fields 10 V/M conforming to IEC 61000-4-3
Electromagnetic compatibility Electrostatic discharge - test level: 6 kV (on contact (on metal parts)) conforming-
to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV (in free air (in insulating parts)) conform-
ing to IEC 61000-4-2
Electromagnetic emission class B conforming to IEC 55011
Resistance to electrostatic discharge 6 KV on contact (on metal parts) conforming to IEC 61000-4-2
8 KV in free air (in insulating parts) conforming to IEC 61000-4-2
Electromagnetic emission Class B conforming to IEC 55011

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Decla-
ration
Mercury free Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS Declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins

Contractual warranty
Warranty 18 months

Product Life Status : Commercialised

2
PANEL ATS 1600A
No Description Qty Satuan Spesifikasi
BOX
1 BOX PANEL H1000 X W600 X D500 2 UNIT LOCAL
INCOMING
2 MCCB 3P 1600A 70kA NS1600H Microligic 2.0 1 PCS SCHNEIDER
3 CHANGE OVER SWITCH 1600A 1 PCS SOCOMEC
4 CURRENT TRANSFORMER 1600/5A 6 PCS HOWIG
5 RELAY CONTROL 1 LOT OMRON
6 TIMER 220VAC 2 PCS OMRON
7 DIGITAL POWER METSEPM2120 2 PCS SCHNEIDER
8 TOMBOL ON 2 PCS HOWIG
9 TOMBOL OFF 2 PCS HOWIG
10 SELECTOR M-O-A 2 PCS HOWIG
11 PILOT LAMP 11 PCS HOWIG
12 MCB CONTROL 10 PCS SCHNEIDER
13 LAMPU 2 PCS PHILLIPS
14 LIMIT SWITCH 2 PCS -
15 TERMINAL CABLE 1 LOT TAB
16 BUSBAR 1 LOT Ex-Japan
+ SUPPORT 1 LOT HOWIG
17 WIRING & ACC 1 LOT ASP
MCC FIX TYPE
No Description Qty Satuan Spesifikasi
BOX
1 BOX PANEL H800 X W600 X D500 3 Unit Local
BREAKER
2 MCCB 3P 160-400A 36kA NSX400F Micrologic 2.0 6 Pcs Schneider
3 MCCB 3P 100-250A 36kA NSX250F Micrologic 2.0 2 Pcs Schneider
ACCSESORIS BREAKER
4 Extend Rotari Handle (standart type) 8 pcs Schneider
5 OF/SDE/SDV 8 Pcs Schneider
6 DIGITAL POWER METSEPM2120 1 Pcs Schneider
7 CT 1600/5A 3 Pcs Howig
8 PILOT LAMP 19 Pcs Howig
9 TERMINAL CABLE 1 Lot TAB
10 CABLE POWER 1 Lot Jembo
11 BUSBAR 1 Lot Ex-Japan
+ SUPPORT BUSBAR 1 Lot Howig
12 WIRING & ACC 1 Lot SI
Project : Pembelian Material EDG Automation & Jasa Instalasi EDG Automation & Modifikasi Panel Distribusi
Location : PT. Pertamina Hulu Energi NSB

BILL OF QUANTITY PANEL SYNCHRON 800A


No Description Qty Satuan Spesifikasi
BOX
1 BOX Panel H2000 x W1000 x D800 3 Unit Local
INCOMING
2 MCCB 3P 800A 70kA NS800H Micrologic 2.0 1 PCS Schneider
+ OF/SD/SDE 3 PCS Schneider
+ INST. UNDER VOLTAGE RELEASE (MN) 3 PCS Schneider
+ INST. CLOSING RELEASE (XF) 3 PCS Schneider
OUTGOING
3 MCCB 3P 800A 70kA NS800H Micrologic 2.0 1 PCS Schneider
4 MCCB 4P 1600A 70kA NS1600H Micrologic 2.0 1 PCS Schneider
5 DIGITAL POWER METSEPM2120 2 PCS Schneider
6 GENSET CONTROLLER AGC150 1 PCS DEIF
7 CT 800/5A CL 0,5 10VA 3 PCS HOWIG
8 CT 1600/5A CL 0,5 40VA 3 PCS HOWIG
9 VOLTMETER DC, 0-30V HPM-72/V30 1 PCS HOWIG
10 AMPERMETER DC, 0-20A HPM-72/A20 1 PCS HOWIG
11 PILOT LAMP 18 PCS HOWIG
12 PUSH BUTTON 6 PCS HOWIG
13 EMERGENCY PUSH BUTTON + COVER 1 PCS HOWIG
14 SELECTOR SWITCH M-O-A 3 PCS HOWIG
15 CONTROL RELAY 24VDC 1 LOT OMRON
16 CONTROL RELAY 220 VAC 1 LOT OMRON
17 LAMPU TL - T5 3 PCS VIGA
18 LIMIT SWITCH 3 PCS MOUZEN
19 BATTERY CHARGER 1PH 10/24VDC BL10 1 PCS ASPIRE
20 HORN 24VDC 1 PCS ASPECIUS
21 TERMINAL BLOCK 4mm 1 LOT TAB
22 MCB CONTROL 24 PCS Schneider
23 BUSBAR (CU) 1 LOT IMPORT
+ BUSBAR SUPPORT 1 LOT HOWIG
24 WIRING & ACCSESORIS 1 LOT SI

You might also like