Passive xWDM Networking Dec 2019

Passive Multiplexers
and OADMs
More flexibility for less cost
Passive xWDM Networking Dec 2019

WDM NETWORKING, BASICS

Wavelength division multiplexing, WDM, has long been the technology of choice for transporting large amounts of data
between sites. It increases bandwidth by allowing different data streams to be sent simultaneously over a single optical
fiber network. In this way WDM maximizes the utilization of the fiber and helps optimize network investments.

The foundation of WDM lies in the ability to send different data types over
fiber networks in the form of light. By allowing different light channels, each
with a unique wavelength, to be sent simultaneously over an optical fiber
network a single virtual fiber network is created. Instead of using multiple
fibers for each and every service, a single fiber can be shared for several
services.

In this way WDM increases the bandwidth and maximizes the usefulness
of fiber. Fiber rental or purchase represents a significant share of
networking costs. So using an existing fiber to transport multiple traffic
channels can generate substantial savings.

CWDM and DWDM

WDM comes in two flavors: Coarse WDM (CWDM) and Dense WDM (DWDM).

The CWDM band can be divided into a low channel band (1271nm to 1451nm)
and a high channel band (1471nm to 1611nm). The wavelength grid is at
20nm separation as defined in the ITU-T standard G.694.2.

CWDM channels are carried on single-mode fibers where the lower


CWDM channel band faces a higher intrinsic attenuation and many older
fibers have also a high attenuation area (called “water-peak”) which together
will limit the bridgeable distance.

For longer distances or where the link attenuation is high, a CWDM solution could be limited to using the high CWDM
channel band where the intrinsic fiber attenuation is lower. It is thus important to measure the actual characteristics
(such as attenuation and chromatic dispersion) of the actual fiber link to determine how many CWDM channels that can
be deployed and what distance that can be bridged.

There are no cost-effective amplifiers that can span over the wide wavelength band of CWDM and consequently low
insertion losses of the CWDM filters are critical to bridge the required distances.

The DWDM band can be divided into many bands, but the most used is the
C-band (1530nm – 1565nm) where you have the lowest fiber attenuation and
where standard optical EDFA amplifiers can be used to extend the bridgeable distance.

Different channel grids are defined by ITU-T in recommendation G.692.1 and the
actual selection is based on a balance of e.g. cost, modulation techniques and
bit/baud rates.

A channel spacing of 100GHz is perhaps the most commonly used in the industry
since the cost profile of the involved components (optical transceivers, filters etc.) are lower as compared to e.g. 50GHz
components. High capacity links will however require denser channel grids or extend into the adjacent L-band (1565nm
– 1625nm) to provide additional channels.
Passive xWDM Networking Dec 2019

Optical filters

Optical filters are the components used to multiplex and demultiplex the optical channels. There are two main types of
optical filters, Mux/Demux and Optical Add/Drop Multiplexer (OADM). The filters are typically passive devices and can
be placed in locations without electrical power. They are also vendor solution independent since no SW integration is
required. All together this provides an increased reliability as compared to active components.

A Mux/Demux unit terminates all the wavelengths on the WDM system and is typically used
as end nodes in a point to point or bus network or as head-end nodes in a ring network.

An OADM unit terminates a subset of wavelengths in a WDM network. OADM’s typically


add/drop 1, 2, or 4 wavelengths and the remaining wavelengths are expressed through
the filter. OADM filters are ideal for creating bus or ring networks or where only a few
channels are required at specific sites.

Fiber pair vs single fiber operation

Fiber-optical communication commonly uses fiber pairs for bi-directional communication. In WDM applications single-
fiber solutions are also possible and Smartoptics have developed a full range of CWDM and DWDM single fiber
Mux/Demux’es and OADM’s to accommodate these requirements. In single fiber applications, different wavelengths are
used to generate bi-directional connections.

Fiber-pair operation Single-fiber operation


Bi-directional configuration using same Bi-directional configuration using two different
wavelength on two separate fiber strands. wavelengths on a single fiber.
1 fiber dedicated for transmit direction 1 wavelength dedicated for transmit direction
1 fiber dedicated for receive direction 1 wavelength dedicated for receive direction

Knowing the system losses

Optical path loss calculation example:

The light is attenuated as it travels through the fiber, through


fiber splices, through patch panels and as it passed through the optical
Mux/Demuxes and OADM filters.

The total optical path loss must include all the above contributors.

The used transceiver has the following optical characteristics:

Transceiver launch power: 0 to +5dBm


Receiver sensitivity: -7 to -23dBm

The power budget for the transceiver is 12 – 23dB, i.e. an optical path loss
of minimum 12dB to avoid the receiver to be overloaded/damaged. The
max loss is 23dB to keep the input power above the receiver sensitivity.

An extra system margin of ~2dB should also normally be added to


compensate for fiber ageing and extra losses due to fiber splicing etc.
Passive xWDM Networking Dec 2019

WIDE RANGE OF PASSIVE FILTERS

Smartoptics offers a wide range of passive filters for CWDM and DWDM applications in both fiber-pair as well as single-
fiber configurations. Two main product ranges are provided:
- T-/M- Series being high-end filters with focus on flexibility and performance.
- H-Series with focus on cost, compactness and extended temperature range.

The below table lists some characteristics of the two product lines.

T-/M-Series H-Series
Low loss Low cost
Flexibility, more variants High density
C-temp range I-temp range
50/100GHz DWDM 100GHz DWDM
Up to 40ch Mux/Demux units Up to 16ch Mux/Demux units
Single-fiber and fiber-pair config. Fiber-pair config.
1RU mounting 1RU mounting

The T-/M-Series filters are based on 1-RU rack-mounted units and plug-in modules that are mounted in a 1 RU, 2-slot
mounting bracket solution.

The H-Series filters are also mounted in a 1 RU mounting bracket solution, but the filter module sizes vary depending on
type of filter. The H-Series is a relatively new product line and additional filters will be added over time.

H-Series

T-/M- Series

The below figure shows a 16ch DWDM filter configuration from the M-Series and H-Series. The M-filter filter is a rack-
mounted 1RU device while the H-filter is a module that is mounted in the 1RU brackets.
As seen, the H-Series option occupies about 25% of the width as compared to the M-filter. The remaining space can be
used to insert additional filters.

The link loss for the H-Series configuration is 6.5dB (worst case) and the upgrade port will add on 4.8dB.
The M-filter has a link loss of 5.65dB and the upgrade port will add on 1.0dB.

The M-filter is thus better suited for future upgrades since the added loss through the upgrade port is far less than the
H-Series filter. The H-Series filter however, occupies less space and additional filters can be added within the same 1RU
slot.

The selection between T-/M-Series and H-Series is thus dependent on physical space requirements, upgrade needs,
optical performance etc. Please see tables below on optical performance and physical size data.
Passive xWDM Networking Dec 2019

H-SERIES
The H-Series currently consist of three CWDM
Mux/Demux units and four different DWDM Mux/DeMux
and OADM filter unit types.

The H-MD-C08 is a CWDM Mux/Demux covering the


lower CWDM band. Two wavelengths are skipped to
avoid the higher attenuation in the “water-peak” that is
present in legacy SM fiber types. The other two CWDM
filters operate in the high CWDM band.

The DWDM filters have monitor ports. These ports tap


off about 1% of the transmitted and received line signal.
This provides the ability to monitor the channel power
levels via a connected Optical Channel Monitoring
(OCM) device or an optical spectrum analyzer.

Almost all Mux/Demux units have an extension port


enabling additional Mux/Demux units to be connected
to provide an upgrade path to higher capacity.

The size of the filter units runs from 55 to 113mm in


width, depending on number of ports. Any combination
of filter modules can be mounted in the 422mm wide
slot of the mounting bracket.

See technical details below.


Passive xWDM Networking Dec 2019

T-/M-SERIES CWDM FILTERS


Fiber-pair configurations:

The CWDM Mux/Demux units in the T-Series covers


both the low as well as the high CWDM band.
One difference vs H-Series is that the filters in the
low band are intended to more recent SM-fibers
not having the “water-peak”. There are consequently
no skipped wavelengths.

There are three different Mux/Demux’es for the high


CWDM band:

- T-3009 with a 1310-port


- T-3009M with a 1310-port and monitor port
- T-3008 with no extension/monitor ports

The 1310nm port is intended for legacy 1310nm


equipment. It can also be used to connect the low
CWDM band Mux/Demux’es T-3016 or T-3012 to
extend the number of channels.

Two Mux/Demux units are provided for the low CWDM


band:

- T-3016 for 8 channels


- T-3012 for 4 channels

Single-fiber configurations:

In a fiber-pair configuration the Mux/Demux units at the end


points are identical since the same wavelengths are used in
both directions for a connection. In a single-fiber configuration
two different wavelengths are used and consequently the two
Mux/Demux units are different, i.e. “mirrored”.
The two versions in the pair are denoted “A” and “B”.

There are two pairs of Mux/Demuxes for single-fiber operation.

- T-3209A and T-3209B enabling 9 bi-directions channels


- T-3204A and T-3204B enabling 4 bi-directions channels

In a single-fiber configuration there is no need to distinguish


between a transmit and receive line fiber. Patching will
consequently be easier.

Moving from a fiber-pair to a single-fiber configuration means that


each fiber in the pair now can be used as two independent
transmission medias.

All CWDM filters are plug-in modules of the same size. Two modules can be fitted in the 1RU mounting brackets
T-3002-19 for 19” mount, T-3002-21 for 21” mount or T-3002-23 for 23” mount.

See technical details in chapter below.


Passive xWDM Networking Dec 2019

T-/M-SERIES DWDM FILTERS


40ch DWDM filters for fiber-pair configurations:

The most commonly used DWDM grid is 100GHz.


The T-/M-Series has two such units providing 40ch DWDM channels:

- M-3840-M covering channels 921-960, plus a Monitor port.


- M-3840-LL a low-loss option without a Monitor port.

The monitor ports tap off about 1% of the transmitted and received line signal.
This provides the ability to monitor the channel power levels via a connected
Optical Channel Monitoring (OCM) device or an optical spectrum analyzer.

The number of DWDM channel can be doubled by using filters operating


at the 50GHz grid. The T-/M-Series has two such filters:

- M-5841-E covering the even 50GHz channels, plus an upgrade port.


- M-5840-O covering the odd 50GHz channels.

The figures show the supported DWDM channels.

By connecting the M-5840-O line signal to the Upgrade port of the M-5841-E
a full 80ch @ 50GHz configuration is provided.

See technical details in separate chapter below.

32ch & 16ch DWDM filters for fiber-pair configurations:

The T-/M-Series has a 32ch DWDM Mux/Demux


option as well as two 16ch options:

- M-3832-M a 32ch Mux/Demux with Monitor port


- M-3817-921936-M a 16ch Mux/Demux with Upgrade &
Monitor port.
- M-3817-943958-M a 16ch Mux/Demux with Upgrade &
Monitor port.

The two 16ch filters can be connected via the Upgrade port
to provide the full 32ch count, having the same DWDM
channels as the 32ch M-3832-M unit.

The figures show the supported DWDM channels.

All 40/32/16ch DWDM Mux/Demux filters are


1RU rack-mounted units.
Passive xWDM Networking Dec 2019

8ch DWDM filters for fiber-pair configurations:

The 8ch DWDM filters belong to the same “family” as the 32ch and 16ch
filters, i.e. they cover the same DWDM channels.

Each of the filters have an Expansion port and a Monitor port. The monitor
ports tap of about 1% of the transmitted and received line signal.
This provides the ability to monitor the channel power levels via a connected
Optical Channel Monitoring (OCM) device or an optical spectrum analyzer.

The Expansion port provides an upgrade path by connecting two or more


filters as shown in the example below.

The 8ch DWDM filters can optionally be used together with the 16ch filters as well in order to provide a more granular
upgrade in capacity.

The 8ch DWDM filters are plug-in modules of the same size. Two modules can be fitted in the 1RU mounting brackets
M-ADJ-19.

OADM DWDM filters for fiber-pair configurations:

The OADM-filters are provided in both 1-way as well as 2-way options. Each with 1ch, 2ch and 4ch add/drop
capabilities.

The 1ch add/drop filters are


provided in 32 wavelength
versions.

The 2ch add/drop filters are


provided in 16 wavelength
versions.

The 4ch add/drop filters are


provided in 8 wavelength
versions.

The covered channel range


matches the 32, 16 and 8ch
DWDM filters.

The 1-way filters have the extension “-LT”. Note that the add/drop is made to/from the Line 1 side.
The 2-way filters add/drop same channels in east and west direction.

The OADM filters are plug-in modules of the same size. Two modules can be fitted in the 1RU mounting brackets
M-ADJ-19.
Passive xWDM Networking Dec 2019

DWDM OADM filters for fiber-pair configurations with Booster/Pre-amp Access (BPA):

A special version of the 2-way, 4ch add/drop OADM filter has access to the add/drop channels before they are coupled
to the line. The intention with this filter is to enable insertion of a Booster and/or Pre-amplifier to compensate for fiber
and filter losses. The figure to the right shows an example where a Pre-amplifier is inserted.

Eight wavelength versions are provided. The OADM filters versions are plug-in modules of the same size. Two modules
can be fitted in the 1RU mounting brackets M-ADJ-19.

DWDM filters for singe-fiber configurations:

In a fiber-pair configuration the Mux/Demux units at the end


points are identical since the same wavelength is used in
both directions for a connection. In a single-fiber configuration
two different wavelengths are used and consequently the two
Mux/Demux units are different, i.e. “mirrored”.
The two versions in the pair are denoted “A” and “B”.

There are two pairs of DWDM Mux/Demuxes for single-fiber operation.

- T-3909A and T-3909B enabling 8 bi-directions channels between 921 – 939,


with an Upgrade port to enable 8 additional channels via T-3908A and T-3908B.
- T-3908A and T-3908B enabling 8 bi-directions channels between 941 – 959

In a single-fiber configuration there is no need to distinguish


between a transmit and receive line fiber. Patching will
consequently be easier. The complexity lies in that transceivers with different
wavelengths must be used at the respective ends.

T-/M-SERIES WIDE BAND 1310nm LEGACY & 1550 CWDM-BAND MUX/DEMUX


The T-3001 band filter is intended for cases where a legacy 1310nm channel is to be combined
with CWDM channels in the upper CWDM band (1460 nm - 1630 nm). The figure shows an example configuration
where this could be used.
Passive xWDM Networking Dec 2019

DWDM filters for 1531nm and 1551nm CWDM channels:

The T-3809 and T-3808 are DWDM Mux/Demux units having a channel plan
that allows them to be connected to a 1551nm port on a CWDM filter.

The T3809 MuxDeMux has an Upgrade port to which the T-3808 can be
connected, providing 8+8 DWDM channels to be carried over a CWDM link.

Further expansion can be provided via the T-3810 DWDM Mux/Demux,


having a channel plan that fits into the 1531nm CWDM window.

The figure below shows an example where these DWDM filters are connected
to the respective ports of the CWDM Mux/Demux T-3008. This configuration will
provide 6 CWDM channels and 26 DWDM channels sharing the same fiber link.
Passive xWDM Networking Dec 2019

TECHNICAL DATA H-SERIES

H-MD-C05 (CWDM) Unit Value


Channels nm 1471, 1491, 1591, 1611
Extension port channels nm 1271-1451, 1511-1571
Link loss, per channel (A) dB < 3.0
Insertion loss, extension port (B) dB < 1.8
Module width mm 55
Connector type - LC/UPC
Mounting bracket - H-Chassi-1RU
o
Operating temperature C -40 to +85

H-MD-C08 (CWDM) Unit Value


Channels nm 1271, 1291, 1311, 1331, 1351, 1371,
1431, 1451
Link loss, per channel (A) dB < 4.2
Module width mm 75
Connector type - LC/UPC
Mounting bracket - H-Chassi-1RU
o
Operating temperature C -40 to +85

H-MD-C09 (CWDM) Unit Value


Channels nm 1471, 1491, 1511, 1531, 1551, 1571,
1591, 1611
Extension port channels nm 1271-1451
Link loss, per channel (A) dB < 4.5
Insertion loss, extension port (B) dB < 3.5
Module width mm 75
Connector type - LC/UPC
Mounting bracket - H-Chassi-1RU
o
Operating temperature C -40 to +85

H-MD-09-xxx-yyy (DWDM) Unit Value


H-MD-09-921-928 THz 192.1 to 192.8
H-MD-09-929-936 THz 192.9 to 193.6
Channels H-MD-09-937-944 THz 193.7 to 194.4
H-MD-09-945-952 THz 194.5 to 195.2
H-MD-09-953-960 THz 195.3 to 196.0
Channel spacing GHz 100
Channel count - 8
Link loss, per channel (A) dB < 4.5
Insertion loss, per channel (B) dB < 3.1
Insertion loss, extension port (C) dB < 3.5
Insertion loss, monitor port dB 18 – 22
Module width mm 84
Connector type - LC/UPC
Mounting bracket - H-Chassi-1RU
o
Operating temperature C -40 to +85

H-MD-016-xxx-yyy (DWDM) Unit Value


H-MD-16-921-936 THz 192.1 to 193.6
Channels
H-MD-16-937-952 THz 193.7 to 195.2
Channel spacing GHz 100
Channel count - 16
Link loss, per channel (A) dB < 6.5
Insertion loss, per channel (B) dB < 4.4
Insertion loss, extension port (C) dB < 4.8
Insertion loss, monitor port dB 18 – 22
Module width mm 113
Connector type - LC/UPC
Mounting bracket - H-Chassi-1RU
o
Operating temperature C -40 to +85
Passive xWDM Networking Dec 2019

H-OADM1x4-xxx-yyy (DWDM) Unit Value


H-OADM1x4-921-924 THz 192.1 to 192.4
H-OADM1x4-925-928 THz 192.5 to 192.8
H-OADM1x4-929-932 THz 192.9 to 193.2
H-OADM1x4-933-936 THz 193.3 to 193.6
H-OADM1x4-937-940 THz 193.7 to 194.0
Channels
H-OADM1x4-941-944 THz 194.1 to 194.4
H-OADM1x4-945-948 THz 194.5 to 194.8
H-OADM1x4-949-952 THz 194.9 to 195.2
H-OADM1x4-953-956 THz 195.3 to 195.6
H-OADM1x4-957-960 THz 195.7 to 196.0
Channel spacing GHz 100
Insertion loss, pass-through E-W (A) dB < 1.8
Add/drop loss (B) dB < 2.5
Link loss, per channel (C) dB < 3.5
Insertion loss, monitor dB 18 - 22
Module width mm 65
Connector type - LC/UPC
Mounting bracket - H-Chassi-1RU
o
Operating temperature C -40 to +85

H-OADM2x4-xxx-yyy (DWDM) Unit Value


H-OADM2x4-921-924 THz 192.1 to 192.4
H-OADM2x4-925-928 THz 192.5 to 192.8
H-OADM2x4-929-932 THz 192.9 to 193.2
H-OADM2x4-933-936 THz 193.3 to 193.6
H-OADM2x4-937-940 THz 193.7 to 194.0
Channels
H-OADM2x4-941-944 THz 194.1 to 194.4
H-OADM2x4-945-948 THz 194.5 to 194.8
H-OADM2x4-949-952 THz 194.9 to 195.2
H-OADM2x4-953-956 THz 195.3 to 195.6
H-OADM2x4-957-960 THz 195.7 to 196.0
Channel spacing GHz 100
Insertion loss, pass-through E-W (A) dB < 3.2
Add/drop loss (B) dB < 2.5
Link loss, per channel (C) dB < 3.5
Insertion loss, monitor dB 18 - 22
Module width mm 84
Connector type - LC/UPC
Mounting bracket - H-Chassi-1RU
o
Operating temperature C -40 to +85

MOUNTING BRACKETS AND MECHANICAL DIMENSIONS H-SERIES

H-Chassi-1RU Unit Value


Rack mount - 19”
Mounting depth (flush mount) mm 158
Mounting depth (recessed mount) mm 211
Height mm 44.45 (1 RU)
Slot width mm 422
Total width mm 483
Passive xWDM Networking Dec 2019

TECHNICAL DATA T-SERIES CWDM MUX/DEMUX’ES


CWDM Fiber-pair configurations

T-3009 Unit Value


Channels nm 1471, 1491, 1511, 1531, 1551 1571,
1591, 1611
Extension port channels nm 1264 - 1438
Link loss, per channel (A) dB < 3.2
Link loss 1551nm (A) dB < 2.2
Link loss, extension port (B) dB < 1.8
Module width mm see separate figure
Connector type - LC/UPC
Mounting brackets - T-3002-19
o
Operating temperature C 0 to +70

T-3009-M Unit Value


Channels nm 1471, 1491, 1511, 1531, 1551 1571,
1591, 1611
Extension port channels nm 1264 - 1438
Link loss, per channel (A) dB < 3.3
Link loss 1551nm (A) dB < 2.3
Link loss, extension port (B) dB < 2.0
Insertion loss, monitor dB 17 - 24
Module width mm see separate figure
Connector type - LC/UPC
Mounting brackets - T-3002-19
o
Operating temperature C 0 to +70

T-3008 Unit Value


Channels nm 1471, 1491, 1511, 1531, 1551 1571,
1591, 1611
Link loss, per channel (A) dB < 2.8
Link loss 1551nm (A) dB < 1.8
Module width mm see separate figure
Connector type - LC/UPC
Mounting brackets - T-3002-19
o
Operating temperature C 0 to +70

T-3016 Unit Value


Channels nm 1291, 1311, 1331, 1351 1371, 1391,
1411, 1431
Link loss, per channel (A) dB < 2.8
Link loss, with T-3009 (B) dB < 4.6
Module width mm see separate figure
Connector type - LC/UPC
Mounting brackets - T-3002-19
o
Operating temperature C 0 to +70

T-3012 Unit Value


Channels nm 1271, 1291, 1311, 1331
Link loss, per channel (A) dB < 2.0
Module width mm see separate figure
Connector type - LC/UPC
Mounting brackets - T-3002-19
o
Operating temperature C 0 to +70
Passive xWDM Networking Dec 2019

CWDM Single-fiber configurations

T-3209A / T-3209B Unit Value


T-3209A: Channels Tx direction 1) nm 1291, 1331, 1371, 1411, 1451, 1491,
1531, 1571, 1611
T-3209A: Channels Rx direction nm 1271, 1311, 1351, 1391, 1431, 1471,
1511, 1551, 1591
T-3209B: Channels Tx direction 1) nm 1271, 1311, 1351, 1391, 1431, 1471,
1511, 1551, 1591
T-3209B: Channels Rx direction nm 1291, 1331, 1371, 1411, 1451, 1491,
1531, 1571, 1611
Link loss, per channel (A) dB < 5.3
Module width mm see separate figure
Connector type - LC/UPC
Mounting brackets - T-3002-19
o
Operating temperature C 0 to +70
1)
Equals the wavelengths used in transmit direction, i.e. what type of transceiver
that shall be connected to this Mux/Demux unit.

T-3204A / T-3204B Unit Value


T-3204A: Channels Tx direction 1) nm 1491, 1531, 1571, 1611
T-3204A: Channels Rx direction nm 1471, 1511, 1551, 1591
T-3204B: Channels Tx direction 1) nm 1471, 1511, 1551, 1591
T-3204B: Channels Rx direction nm 1491, 1531, 1571, 1611
Link loss, per channel (A) dB < 2.8
Module width mm see separate figure
Connector type - LC/UPC
Mounting brackets - T-3002-19
o
Operating temperature C 0 to +70
1)
Equals the wavelengths used in transmit direction, i.e. what type of transceiver
that shall be connected to this Mux/Demux unit.
Passive xWDM Networking Dec 2019

TECHNICAL DATA M-SERIES DWDM MUX/DEMUX’ES

M-5841-E Unit Value


Channels THz 192.10 to 196.00
Number of channels - 40
Channel spacing GHz 50
Link loss, per channel (A) dB < 10.0
Link loss, UPG (B) dB < 3.0
Module width mm 1RU, 19” rack mount
Connector type - LC/UPC
Mounting bracket - NA
o
Operating temperature C 0 to +70

M-5840-O Unit Value


Channels THz 192.15 to 196.05
Number of channels - 40
Channel spacing GHz 50
Link loss, per channel (A) dB < 8.0
Module width mm 1RU, 19” rack mount
Connector type - LC/UPC
Mounting bracket - NA
o
Operating temperature C 0 to +70

M-3840-M Unit Value


Channels THz 192.1 to 196.0
Number of channels - 40
Channel spacing GHz 100
Link loss, per channel (A) dB < 12.2
Insertion loss, per channel (B) dB < 6.4
Insertion loss, Tx monitor port dB 24 – 27 (1%)
Insertion loss, Rx monitor port 12 – 14 (5%)
Module width mm 1RU, 19” rack mount
Connector type - LC/UPC
Mounting bracket - NA
o
Operating temperature C -5 to +70

M-3840-LL Unit Value


Channels THz 192.1 to 196.0
Number of channels - 40
Channel spacing GHz 100
Link loss, per channel (A) dB < 7.5
Insertion loss, per channel (B) dB < 6.0
Module width mm 1RU, 19” rack mount
Connector type - LC/UPC
Mounting bracket - NA
o
Operating temperature C 0 to +70
Passive xWDM Networking Dec 2019

M-3832-M Unit Value


THz 192.1 to 193.6
Channels
194.3 to 195.8
Number of channels - 32
Channel spacing GHz 100
Link loss, per channel (A) dB < 6.4
Insertion loss, channel to line (B) dB < 5.0
Insertion loss, monitor port dB 19 – 22
Module width mm 1RU, 19” rack mount
Connector type - LC/UPC
Mounting bracket - NA
o
Operating temperature C 0 to +70

M-3817-xxxyyy-M Unit Value


Channels M-3817-921936-M THz 192.1 to 193.6
M-3817-943958-M THz 194.3 to 195.8
Number of channels - 16
Channel spacing GHz 100
Link loss, per channel (A) dB < 5.65
Insertion loss, channel to line (B) dB < 4.0
Link loss UPG port (C) dB < 2.0
Insertion loss, monitor port dB 19 – 22
Module width mm 1RU, 19” rack mount
Connector type - LC/UPC
Mounting bracket - NA
o
Operating temperature C 0 to +70

M-3809-xxxyyy-M Unit Value


Channels M-3809-921928-M THz 192.1 to 192.8
M-3809-929936-M THz 192.9 to 193.6
M-3809-943950-M THz 194.3 to 195.0
M-3809-951958-M THz 195.1 to 195.8
Number of channels - 8
Channel spacing GHz 100
Link loss, per channel (A) dB < 4.8
Insertion loss, channel to line (B) < 2.8
Link loss Exp port (C) dB < 1.7
Insertion loss, monitor port dB 18 – 22
Module width mm see separate figure
Connector type - LC/UPC
Mounting bracket - M-ADJ-19
o
Operating temperature C 0 to +70
Passive xWDM Networking Dec 2019

TECHNICAL DATA M-SERIES DWDM OADM’S

M-OADM1-xxx-LT (DWDM) Unit Value


M-OADM1-921-LT THz 192.1
M-OADM1-922-LT THz 192.2
M-OADM1-923-LT THz 192.3
M-OADM1-924-LT THz 192.4
M-OADM1-925-LT THz 192.5
M-OADM1-926-LT THz 192.6
M-OADM1-927-LT THz 192.7
M-OADM1-928-LT THz 192.8
M-OADM1-929-LT THz 192.9
M-OADM1-930-LT THz 193.0
M-OADM1-931-LT THz 193.1
M-OADM1-932-LT THz 193.2
M-OADM1-933-LT THz 193.3
M-OADM1-934-LT THz 193.4
M-OADM1-935-LT THz 193.5
M-OADM1-936-LT THz 193.6
Channels
M-OADM1-943-LT THz 194.3
M-OADM1-944-LT THz 194.4
M-OADM1-945-LT THz 194.5
M-OADM1-946-LT THz 194.6
M-OADM1-947-LT THz 194.7
M-OADM1-948-LT THz 194.8
M-OADM1-949-LT THz 194.9
M-OADM1-950-LT THz 195.0
M-OADM1-951-LT THz 195.1
M-OADM1-952-LT THz 195.2
M-OADM1-953-LT THz 195.3
M-OADM1-954-LT THz 195.4
M-OADM1-955-LT THz 195.5
M-OADM1-956-LT THz 195.6
M-OADM1-957-LT THz 195.7
M-OADM1-958-LT THz 195.8
Channel spacing GHz 100
Insertion loss, pass-through E-W (A) dB < 0.8
Add/drop loss (B) dB < 1.2
Link loss (C) dB < 2.4
Module width mm see separate figure
Connector type - LC/UPC
Mounting bracket - M-ADJ-19
o
Operating temperature C 0 to +70

M-OADM2-xxxyyy-LT (DWDM) Unit Value


M-OADM2-921922-LT THz 192.1, 192.2
M-OADM2-923924-LT THz 192.3, 192.4
M-OADM2-925926-LT THz 192.5, 192.6
M-OADM2-927928-LT THz 192.7, 192.8
M-OADM2-929930-LT THz 192.9, 193.0
M-OADM2-931932-LT THz 193.1, 193.2
M-OADM2-933934-LT THz 193.3, 193.4
M-OADM2-935936-LT THz 193.5, 193.6
Channels
M-OADM2-943944-LT THz 194.3, 194.4
M-OADM2-945946-LT THz 194.5, 194.6
M-OADM2-947948-LT THz 194.7, 194.8
M-OADM2-949950-LT THz 194.9, 195.0
M-OADM2-951952-LT THz 195.1, 195.2
M-OADM2-953954-LT THz 195.3, 195.4
M-OADM2-955956-LT THz 195.5, 195.6
M-OADM2-957958-LT THz 195.7, 195.8
Channel spacing GHz 100
Insertion loss, pass-through E-W (A) dB < 1.2
Add/drop loss (B) dB < 1.8
Link loss (C) dB < 2.4
Module width mm see separate figure
Connector type - LC/UPC
Mounting bracket - M-ADJ-19
o
Operating temperature C 0 to +70
Passive xWDM Networking Dec 2019

M-OADM4-xxxyyy-LT (DWDM) Unit Value


M-OADM4-921924-LT THz 192.1, 192.2, 192.3, 192.4
M-OADM4-925928-LT THz 192.5, 192.6, 192.7, 192.8
M-OADM4-929932-LT THz 192.9, 193.0, 193.1, 193.2
M-OADM4-933936-LT THz 193.3, 193.4, 193.5, 193.6
Channels
M-OADM4-943946-LT THz 194.3, 194.4, 194.5, 194.6
M-OADM4-947950-LT THz 194.7, 194.8, 194.9, 195.0
M-OADM4-951954-LT THz 195.1, 195.2, 195.3, 195.4
M-OADM4-955958-LT THz 195.5, 195.6, 195.7, 195.8
Channel spacing GHz 100
Insertion loss, pass-through E-W (A) dB < 0.6
Add/drop loss (B) dB < 2.8
Link loss (C) dB < 4.2
Module width mm see separate figure
Connector type - LC/UPC
Mounting bracket - M-ADJ-19
o
Operating temperature C 0 to +70

M-OADM1-xxx (DWDM) Unit Value


M-OADM1-921 THz 192.1
M-OADM1-922 THz 192.2
M-OADM1-923 THz 192.3
M-OADM1-924 THz 192.4
M-OADM1-925 THz 192.5
M-OADM1-926 THz 192.6
M-OADM1-927 THz 192.7
M-OADM1-928 THz 192.8
M-OADM1-929 THz 192.9
M-OADM1-930 THz 193.0
M-OADM1-931 THz 193.1
M-OADM1-932 THz 193.2
M-OADM1-933 THz 193.3
M-OADM1-934 THz 193.4
M-OADM1-935 THz 193.5
M-OADM1-936 THz 193.6
Channels
M-OADM1-943 THz 194.3
M-OADM1-944 THz 194.4
M-OADM1-945 THz 194.5
M-OADM1-946 THz 194.6
M-OADM1-947 THz 194.7
M-OADM1-948 THz 194.8
M-OADM1-949 THz 194.9
M-OADM1-950 THz 195.0
M-OADM1-951 THz 195.1
M-OADM1-952 THz 195.2
M-OADM1-953 THz 195.3
M-OADM1-954 THz 195.4
M-OADM1-955 THz 195.5
M-OADM1-956 THz 195.6
M-OADM1-957 THz 195.7
M-OADM1-958 THz 195.8
Channel spacing GHz 100
Insertion loss, pass-through E-W (A) dB < 1.2
Add/drop loss (B) dB < 1.2
Link loss (C) dB < 2.4
Module width mm see separate figure
Connector type - LC/UPC
Mounting bracket - M-ADJ-19
o
Operating temperature C 0 to +70
Passive xWDM Networking Dec 2019

M-OADM2-xxxyyy (DWDM) Unit Value


M-OADM2-921922 THz 192.1, 192.2
M-OADM2-923924 THz 192.3, 192.4
M-OADM2-925926 THz 192.5, 192.6
M-OADM2-927928 THz 192.7, 192.8
M-OADM2-929930 THz 192.9, 193.0
M-OADM2-931932 THz 193.1, 193.2
M-OADM2-933934 THz 193.3, 193.4
M-OADM2-935936 THz 193.5, 193.6
Channels
M-OADM2-943944 THz 194.3, 194.4
M-OADM2-945946 THz 194.5, 194.6
M-OADM2-947948 THz 194.7, 194.8
M-OADM2-949950 THz 194.9, 195.0
M-OADM2-951952 THz 195.1, 195.2
M-OADM2-953954 THz 195.3, 195.4
M-OADM2-955956 THz 195.5, 195.6
M-OADM2-957958 THz 195.7, 195.8
Channel spacing GHz 100
Insertion loss, pass-through E-W (A) dB < 1.8
Add/drop loss (B) dB < 1.8
Link loss (C) dB < 2.4
Module width mm see separate figure
Connector type - LC/UPC
Mounting bracket - M-ADJ-19
o
Operating temperature C 0 to +70

M-OADM4-xxxyyy (DWDM) Unit Value


M-OADM4-921924 THz 192.1, 192.2, 192.3, 192.4
M-OADM4-925928 THz 192.5, 192.6, 192.7, 192.8
M-OADM4-929932 THz 192.9, 193.0, 193.1, 193.2
M-OADM4-933936 THz 193.3, 193.4, 193.5, 193.6
Channels
M-OADM4-943946 THz 194.3, 194.4, 194.5, 194.6
M-OADM4-947950 THz 194.7, 194.8, 194.9, 195.0
M-OADM4-951954 THz 195.1, 195.2, 195.3, 195.4
M-OADM4-955958 THz 195.5, 195.6, 195.7, 195.8
Channel spacing GHz 100
Insertion loss, pass-through E-W (A) dB < 1.2
Add/drop loss (B) dB < 3.2
Link loss (C) dB < 4.2
Module width mm see separate figure
Connector type - LC/UPC
Mounting bracket - M-ADJ-19
o
Operating temperature C 0 to +70
Passive xWDM Networking Dec 2019

M-OADM4-xxxyyy-BPA (DWDM) Unit Value


M-OADM4-921924-BPA THz 192.1, 192.2, 192.3, 192.4
M-OADM4-925928-BPA THz 192.5, 192.6, 192.7, 192.8
M-OADM4-929932-BPA THz 192.9, 193.0, 193.1, 193.2
M-OADM4-933936-BPA THz 193.3, 193.4, 193.5, 193.6
Channels
M-OADM4-943946-BPA THz 194.3, 194.4, 194.5, 194.6
M-OADM4-947950-BPA THz 194.7, 194.8, 194.9, 195.0
M-OADM4-951954-BPA THz 195.1, 195.2, 195.3, 195.4
M-OADM4-955958-BPA THz 195.5, 195.6, 195.7, 195.8
Channel spacing GHz 100
Insertion loss, pass-through E-W (A) dB < 1.2
Insertion loss (B) dB < 1.0
Insertion loss (C) dB < 2.2
Module width mm see separate figure
Connector type - LC/UPC
Mounting bracket - M-ADJ-19
o
Operating temperature C 0 to +70

TECHNICAL DATA T-SERIES DWDM MUX/DEMUX’ES FOR CWDM CHANNELS

T-3808 Unit Value


Channels THz 192.5 to 193.2
Number of channels - 8
Channel spacing GHz 100
Link loss, per channel (A) dB < 3.5
Module width mm see separate figure
Connector type - LC/UPC
Mounting bracket - T-3002-19
o
Operating temperature C 0 to +70

T-3809 Unit Value


Channels THz 193.4 to 194.1
Number of channels - 8
Channel spacing GHz 100
Link loss, per channel (A) dB < 5.0
Link loss, UPG ports (B) dB < 1.2
Module width mm see separate figure
Connector type - LC/UPC
Mounting bracket - T-3002-19
o
Operating temperature C 0 to +70

T-3810 Unit Value


Channels THz 195.1 to 196.0
Number of channels - 10
Channel spacing GHz 100
Link loss, per channel (A) dB < 4.4
Module width mm see separate figure
Connector type - LC/UPC
Mounting bracket - T-3002-19
o
Operating temperature C 0 to +70
Passive xWDM Networking Dec 2019

TECHNICAL DATA T-SERIES WIDE BAND 1310nm & 1550 CWDM-BAND MUX/DEMUX

T-3001 Unit Value


Channels 1310nm port nm 1270 – 1350
1550nm port nm 1460 - 1630
Link loss, per channel (A) dB < 1.5
Insertion loss, per channel (B) dB < 1.0
Module width mm see separate figure
Connector type - LC/UPC
Mounting bracket - T-3002-19
o
Operating temperature C 0 to +70

TECHNICAL DATA T-SERIES DWDM MUX/DEMUX’ES FOR SINGLE FIBER

T-3908A / T-3908B Unit Value


T-3908A: Channels Tx direction 1) THz 194.2, 194.4, 194.7, 194.9
195.2, 195.4, 195.7, 195.9
T-3908A: Channels Rx direction THz 194.1, 194.3, 194.6, 194.8
195.1, 195.3, 195.6, 195.8
T-3908B: Channels Tx direction 1) THz 194.1, 194.3, 194.6, 194.8
195.1, 195.3, 195.6, 195.8
T-3908B: Channels Rx direction THz 194.2, 194.4, 194.7, 194.9
195.2, 195.4, 195.7, 195.9
Channel spacing GHz 100
Number of channels - 8
Link loss, per channel (A) dB <5
Module width mm see separate figure
Connector type - LC/UPC
Mounting brackets - T-3002-19
o
Operating temperature C 0 to +70
1)
Equals the wavelengths used in transmit direction, i.e. what type of transceiver
that shall be connected to this Mux/Demux unit.

T-3909A / T-3909B Unit Value


T-3909A: Channels Tx direction 1) THz 192.2, 192.4, 192.7, 192.9
193.2, 193.4, 193.7, 193.9
T-3909A: Channels Rx direction THz 192.1, 192.3, 192.6, 192.8
193.1, 193.3, 193.6, 193.8
T-3909B: Channels Tx direction 1) THz 192.1, 192.3, 192.6, 192.8
193.1, 193.3, 193.6, 193.8
T-3909B: Channels Rx direction THz 192.2, 192.4, 192.7, 192.9
193.2, 193.4, 193.7, 193.9
Channel spacing GHz 100
Number of channels - 8
Link loss, per channel (A) dB < 5.3
Link loss, upgrade port (B) < 1.8
Module width mm see separate figure
Connector type - LC/UPC
Mounting brackets - T-3002-19
o
Operating temperature C 0 to +70
1)
Equals the wavelengths used in transmit direction, i.e. what type of transceiver
that shall be connected to this Mux/Demux unit.
Passive xWDM Networking Dec 2019

MOUNTING BRACKETS AND MECHANICAL DIMENSIONS M-/T-SERIES

T-Series filters:
Mounting bracket T-3002-19 Unit Value
Rack mount - 19”
Mounting depth (flush mount) mm 191.6
Height mm 44.45 (1 RU)
Slot width mm 189

T-Series plug-in module depth.

Mounting brackets with one module.

M-Series filters:

Mounting bracket M-ADJ-19 Unit Value


Rack mount - 19”
Mounting depth (flush mount) mm 191.6
Height mm 44.45 (1 RU)
Slot width mm 188.4

M-Series plug-in module depth.

Note: T-filters will not fit into mounting bracket for M-Series, and vice-verse.
Passive xWDM Networking Dec 2019

CHANNEL PLAN
DWDM T-Series
channel M-Series selection guide selection
plan guide

Mux/Demux

Mux/Demux

Mux/Demux

Mux/Demux

Expansion
4Ch 2way

2Ch 2way

1Ch 2way
dual fiber

dual fiber

dual fiber
dual fiber

dual fiber

dual fiber
4Ch LT

2Ch LT

1Ch LT

CWDM
SO

OADM

OADM

OADM

OADM

OADM

OADM

OADM
40ch

32ch

16ch
Wave-

8ch
channel
length
ID

9600 1529.55
9590 1530.33

fits into 1530 CWDM


9580 1531.12 M-OADM2- M-OADM2-

M-3809-951958-M
M- M- 957958 957958-LT
9570 1531.90
OADM4- OADM4-

T-3810
9560 1532.68 956958 956958-LT M-OADM2- M-OADM2-
9550 1533.47 955956 955956-LT
9540 1534.25 M-OADM2- M-OADM2-
M-3817-943958-M

M- M- 953954 953954-LT

M-OADM1-xxx-LT
9530 1535.04

M-OADM1-xxx
OADM4- OADM4-
M-3832-M

9520 1535.82 951954 951954-LT M-OADM2- M-OADM2-


9510 1536.61 951952 951952-LT
9500 1537.40 M-OADM2- M-OADM2-
M-3809-943950-M

M- M- 949950 949950-LT
9490 1538.19
OADM4- OADM4-
9480 1538.98 947950 947950-LT M-OADM2- M-OADM2-
9470 1539.77 947948 947948-LT
M-5840-O / M-3840-M / M-3840-LL

9460 1540.56 M-OADM2- M-OADM2-


M- M- 945946 945946-LT
9450 1541.35
OADM4- OADM4-
9440 1542.14 943946 943946-LT M-OADM2- M-OADM2-
9430 1542.94 943944 943944-LT
9420 1543.73
9410 1544.53
Unused wavelength area 9370 to 9420

fits into 1550 CWDM


9400 1545.32
Note that M-3832 does not cover these wavelengths
9390 1546.12

T-3809
9380 1546.92
9370 1547.72
9360 1548.51 M-OADM2- M-OADM2-
M-3809-929936-M

M- M- 935936 935936-LT
9350 1549.32
OADM4- OADM4-
9340 1550.12 933936 933936-LT M-OADM2- M-OADM2-
9330 1550.92 933934 933934-LT
9320 1551.72 M-OADM2- M-OADM2-

(expansion for T-3809)


M-3817-921936-M

M- M- 931932 931932-LT
fits into 1550 CWDM
M-OADM1-xxx-LT

9310 1552.52
M-OADM1-xxx

OADM4- OADM4-
M-3832-M

9300 1553.33 929932 929932-LT M-OADM2- M-OADM2-


T-3808

9290 1554.13 929930 929930-LT


9280 1554.94 M-OADM2- M-OADM2-
M-3809-921928-M

M- M- 927928 927928-LT
9270 1555.75
OADM4- OADM4-
9260 1556.55 925928 925928-LT M-OADM2- M-OADM2-
9250 1557.36 925926 925926-LT
9240 1558.17 M-OADM2- M-OADM2-
M- M- 923924 923924-LT
9230 1558.98
OADM4- OADM4-
9220 1559.79 921924 921924-LT M-OADM2- M-OADM2-
9210 1560.61 921922 921922-LT
Passive xWDM Networking Dec 2019

DWDM
channel H-series selection guide
plan

Mux/Demux

Mux/Demux

4Ch 2-way
dual fiber

dual fiber
4Ch LT

OADM
SO

OADM
16ch
Wave-

8ch
channel
length
ID

9600 1529.55

H-MD-09-953-960
9590 1530.33 H-OADM2x4-957-
H-OADM1x4-957-960
960
9580 1531.12
9570 1531.90
9560 1532.68
9550 1533.47 H-OADM2x4-953-
H-OADM1x4-953-956
956
9540 1534.25
9530 1535.04
9520 1535.82
H-MD-09-945-952

9510 1536.61 H-OADM2x4-949-


H-OADM1x4-949-952
952
9500 1537.40
9490 1538.19
9480 1538.98
H-MD-16-937-952

9470 1539.77 H-OADM2x4-945-


H-OADM1x4-945-948
948
9460 1540.56
9450 1541.35
9440 1542.14
H-MD-09-937-944

9430 1542.94 H-OADM2x4-941-


H-OADM1x4-941-944
944
9420 1543.73
9410 1544.53
9400 1545.32
9390 1546.12 H-OADM2x4-937-
H-OADM1x4-937-940
9380 1546.92 940

9370 1547.72
9360 1548.51
H-MD-09-929-936

9350 1549.32 H-OADM2x4-933-


H-OADM1x4-933-936
936
9340 1550.12
9330 1550.92
9320 1551.72
H-MD-16-921-936

9310 1552.52 H-OADM2x4-929-


H-OADM1x4-929-932
932
9300 1553.33
9290 1554.13
9280 1554.94
H-MD-09-921-928

9270 1555.75 H-OADM2x4-925-


H-OADM1x4-925-928
928
9260 1556.55
9250 1557.36
9240 1558.17
9230 1558.98 H-OADM2x4-921-
H-OADM1x4-921-924
924
9220 1559.79
9210 1560.61
Passive xWDM Networking Dec 2019

CWDM channel
CWDM selection guide
plan

H-Series
T-Series
CWDM

colour
Wave-
channel
length
no.

27 1271

T-3012
29 1291
31 1311
33 1331 T-3016

35 1351
37 1371

H-MD-C08
39 1391
41 1411
43 1431
45 1451
47 1471 grey
49 1491 violet
T-3009 T-3009-M

H-MD-C05
51 1511 blue
H-MD-C09
T-3004
T-3005
T-3008

53 1531 green
55 1551 orange
57 1571 yellow
59 1591 red
61 1611 brown
Passive xWDM Networking Dec 2019

About Smartoptics

Smartoptics offers optical transmission solutions making networks more Norway (HQ)
powerful. Expanding bandwidth without the upfront investment or hassle of Ryensvingen 7
traditional WDM. Our products allow corporate data centers, governments, NO-0680 Oslo, Norway
hosting solution providers and ISPs to build simple, straightforward and cost-
effective solutions to fulfil their ongoing and future network capacity needs. Sweden
Headquartered in Oslo, Norway, Smartoptics is an international provider with Borgarfjordsgatan 6C
thousands of installations all around the world. Our award-winning approach SE-16455 Kista, Sweden
has helped companies from every industry sector stay ahead of expanding
network demands. info@smartopics.com
smartoptics.com