CHAPTER 17 SEISMIC DESIGN REQUIREMENTS FOR SEISMICALLY ISOLATED


2  STRUCTURES

ite rm T
3  17.1 GENERAL

C Fo AF
at
4  Every seismically isolated structure and every portion thereof shall be designed and constructed
5  in accordance with the requirements of this section and the applicable requirements of this

or e R
6  standard.

D
7  17.1.1 Definitions.

U er NT
8  The following definitions apply only apply to the seismically isolated structure provisions of
9  Chapter 17 and are in addition to the definitions presented in Chapter 11.
ot nd E
n
N U M
10  se li
BASE LEVEL: The first level of the isolated structure above the isolation interface.
M

11  DISPLACEMENT RESTRAINT SYSTEM: A collection of structural elements that limits


12  lateral displacement of seismically isolated structures caused by the maximum considered
D ut O

13  earthquake.
C

14  EFFECTIVE DAMPING: The value of equivalent viscous damping corresponding to energy
e C
/

15  dissipated during cyclic response of the isolation system.


rik LI

16  EFFECTIVE STIFFNESS: The value of the lateral force in the isolation system, or an element
o
St B

17  thereof, divided by the corresponding lateral displacement.


PU

18  ISOLATION INTERFACE: The boundary between the upper portion of the structure, which is
o

19  isolated, and the lower portion of the structure, which moves rigidly with the ground.

20  ISOLATION SYSTEM: The collection of structural elements that includes all individual
21  isolator units, all structural elements that transfer force between elements of the isolation system,
22  and all connections to other structural elements. The isolation system also includes the wind-
23  restraint system, energy-dissipation devices, and/or the displacement restraint system if such
24  systems and devices are used to meet the design requirements of this chapter.

1
1  ISOLATOR UNIT: A horizontally flexible and vertically stiff structural element of the isolation
2  system that permits large lateral deformations under design seismic load. An isolator unit is
3  permitted to be used either as part of, or in addition to, the weight-supporting system of the
4  structure.

ite rm T
MAXIMUM DISPLACEMENT: The maximum lateral displacement, excluding additional

C Fo AF

displacement caused by actual and accidental torsion, required for design of the isolation system.

at

7  The maximum displacement is to be computed separately using upper bound and lower bound

or e R
8  properties.

D
9  SCRAGGING: Cyclic loading or working of rubber products, including elastomeric isolators, to

U er NT
10  aeffect effect a reduction in stiffness properties, a portion of which is recovered over time.

11  TOTAL MAXIMUM DISPLACEMENT: The total maximum lateral displacement, including
ot nd E
n
12  additional displacement caused by actual and accidental torsion, required for the verification of
N U M
13  se li
the stability of the isolation system or elements thereof, design of structure separations, and
vertical load testing of isolator unit prototypes. The total maximum displacement is to be
M

14 
15  computed separately using upper bound and lower bound properties.
D ut O

16  WIND-RESTRAINT SYSTEM: The collection of structural elements that provides restraint of
C

17  the seismically isolated structure for wind loads. The wind-restraint system is permitted to be
either an integral part of isolator units or a separate device.
e C

18 
/
rik LI

19  17.1.2 Symbols.


o
St B

20  Symbols presented in this section apply only apply to the seismically isolated structure
PU

21  provisions of Chapter 17 and are in addition to the symbols presented in Chapter 11.
o

22  b = Sshortest plan dimension of the structure [ft (mm)], measured perpendicular to d

23  BM = Nnumerical coefficient as set forth in Table 17.5-1, for effective damping equal to βM

24  Cvx = Vvertical distribution factor

25  d = Llongest plan dimension of the structure [ft (mm)], measured perpendicular to b

2
1  DM = Mmaximum displacement [in. (mm)], at the center of rigidity of the isolation system in
2  the direction under consideration, as prescribed by Eq.uation (17.5-1)

3  DM = Mmaximum displacement [in. (mm)], at the center of rigidity of the isolation system in

ite rm T
4  the direction under consideration, as prescribed by Eq.uation (17.6-1)

C Fo AF
at
5  DTM = Ttotal maximum displacement [in. (mm)] , of an element of the isolation system including

or e R
6  both translational displacement at the center of rigidity and the component of torsional

D
7  displacement in the direction under consideration, as prescribed by Eq.uation (17.5-3)

8  = Aactual eccentricity [ft (mm)], measured in plan between the center of mass of the structure

U er NT
e

9  above the isolation interface and the center of rigidity of the isolation system, plus accidental
10  eccentricity [ft (mm)] taken as 5% of the maximum building dimension perpendicular to the
ot nd E
n
11  direction of force under consideration
N U M

12 
se li
Eloop = Eenergy dissipated [kip-in. (kN-mm)] , in an isolator unit during a full cycle of reversible
M

13  load over a test displacement range from Δ to Δ– , as measured by the area enclosed by the loop
D ut O

14  of the force-deflection curve


C

15  F  = Mmaximum positive force [kips (kN)] in an isolator unit during a single cycle of prototype
testing at a displacement amplitude of Δ
e C
/

16 
rik LI

17  F  = Mminimum negative force [kips (kN)] in an isolator unit during a single cycle of prototype
o
St B

18  testing at a displacement amplitude of Δ–


PU

Fx = Llateral seismic force [kips (kN)] at level x , as prescribed by Eq.uation (17.5-9)


o

19 

20  hi, hl , hx = Hheight [ft (m)] above the isolation interface of level i , l , or x

21  hsx = Hheight of story below level x

22  keff = Eeffective stiffness [kip/in (kN/mm)] of an isolator unit, as prescribed by Eq.uation (17.8-
23  1)

3
1  kM = Eeffective stiffness [ kip / in. ( kN / mm )] of the isolation system in the horizontal direction
2  under consideration

3  L = Eeffect of live load in Chapter 17

ite rm T
4  N = Nnumber of isolator units

C Fo AF
at
5  PT = Rratio of the effective translational period of the isolation system to the effective torsional

or e R
6  period of the isolation system, as calculated by dynamic analysis or as prescribed by

D
7  Eq.uation 17.5-4 but need not be taken as less than 1.0

U er NT
8  rI = Rradius of gyration of the isolation system [ft (mm)],

9  RI = NMnumerical coefficient related to the type of seismic force-resisting system above the
ot nd E
n
10  isolation system
N U M
se li
M

11  Tfb = Ffundamental period [s] of the structure above the isolation interface, determined using a
12  modal analysis assuming fixed-base conditions
D ut O C

13  TM = Eeffective period [s] of the seismically isolated structure at the displacement DM in the
14  direction under consideration, as prescribed by Eq.uation (17.5-2)
e C
/
rik LI

15  Vb = Ttotal lateral seismic design force or shear on elements of the isolation system or elements
below the isolation system [kips (kN)], as prescribed by Eq.uation (17.5-5)
o

16 
St B
PU

17  Vs = Ttotal lateral seismic design force or shear on elements above the base level [kips (kN)], as
o

18  prescribed by Eq.uation (17.5-6) and the limits of Section 17.5.4.3;

19  Vst = Ttotal unreduced lateral seismic design force or shear on elements above the base level
20  [kips (kN)], as prescribed by Eq.uation (17.5-7)

21  W = Eeffective seismic weight [kips (kN)], of the structure above the isolation interface, as
22  defined by Section 12.7.2

4
1  Ws = Eeffective seismic weight [kips (kN)], of the structure above the isolation interface, as
2  defined by Section 12.7.2, excluding the effective seismic weight [kips (kN)] of the base level

3  wi , wl , wx = Pportion of W that is located at or assigned to level i , l , or x [kips (kN)]

ite rm T
C Fo AF
4  xi , yi = Hhorizontal distances [ft (mm)] from the center of mass to the i th isolator unit in the

at
5  two horizontal axes of the isolation system

or e R
6  y = Ddistance [ft (mm)], between the center of rigidity of the isolation system and the element of

D
7  interest measured perpendicular to the direction of seismic loading under consideration

U er NT
8  βeff = Eeffective damping of the isolation system, as prescribed by Eq.uation (17.8-2)

βM = Eeffective damping of the isolation system at the displacement DM , as prescribed by


ot nd E

n
N U M
10  Eq.uation (17.2-4)
se li
M

11  Δ = Mmaximum positive displacement [in (mm)] of an isolator unit during each cycle of
12  prototype testing
D ut O C

13  Δ– = Mminimum negative displacement [in (mm)] of an isolator unit during each cycle of
14  prototype testing
e C
/

15  λmax = Pproperty modification factor for calculation of the maximum value of the isolator
rik LI

16  property of interest, used to account for all sources of isolator property variability, as defined in
o
St B

17  Section 17.2.8.4


PU

18  λmin = Pproperty modification factor for calculation of the minimum value of the isolator
19  property of interest, used to account for all sources of isolator property variability, as defined in
20  Section 17.2.8.4

21  λ(ae,max) = Pproperty modification factor for calculation of the maximum value of the isolator
22  property of interest, used to account for aging effects and environmental conditions, as defined in
23  Section 17.2.8.4

5
1  λ (ae,min) = Pproperty modification factor for calculation of the minimum value of the isolator
2  property of interest, used to account for aging effects and environmental conditions, as defined in
3  Section 17.2.8.4

ite rm T
4  λ(spec,max) = Pproperty modification factor for calculation of the maximum value of the isolator

C Fo AF
5  property of interest, used to account for permissible manufacturing variation on the average

at
6  properties of a group of same-sized isolators, as defined in Section 17.2.8.4

or e R
7  λ(spec,min) = Pproperty modification factor for calculation of the minimum value of the isolator

D
8  property of interest, used to account for permissible manufacturing variation on the average

U er NT
9  properties of a group of same-sized isolators, as defined in Section 17.2.8.4

10  λ(test,max) = Pproperty modification factor for calculation of the maximum value of the isolator
ot nd E
n
11  property of interest, used to account for heating, rate of loading, and scragging, as defined in
N U M
12 
se li
Section 17.2.8.4
M

13  λ(test,min) = Pproperty modification factor for calculation of the minimum value of the isolator
D ut O

14  property of interest, used to account for heating, rate of loading, and scragging, as defined in
C

15  Section 17.2.8.4


e C
/

16  ΣEM = Ttotal energy dissipated [kip-in. (kN-mm)], in the isolation system during a full cycle of
rik LI

17  response at displacement DM


o
St B

18  Σ | FD |max = Ssum, for all isolator units, of the maximum absolute value of force [kips (kN)], at
PU

19  a positive displacement equal to DM

20  Σ | FD |max = Ssum, for all isolator units, of the maximum absolute value of force [kips (kN)], at

21  a negative displacement equal to DM

22  17.2 GENERAL DESIGN REQUIREMENTS

23  17.2.1 Importance Factor.

6
1  All portions of the structure, including the structure above the isolation system, shall be assigned

2  a risk category in accordance with Table 1.5-1. The Importance Factor, I e , shall be taken as 1.0

3  for a seismically isolated structure, regardless of its risk category assignment.

ite rm T
4  17.2.2 Configuration.

C Fo AF
at
5  Each isolated structure shall be designated as having a structural irregularity if the structural
configuration above the isolation system has a Type 1b horizontal structural irregularity with a

or e R

7  TIR greater than 1.4 , as defined in Table 12.3-1, or Type 1a, 1b, 5a, 5b4a, 4b vertical

D
8  irregularity, as defined in Table 12.3-2.

U er NT
9  17.2.3 Redundancy.

A redundancy factor, ρ, shall be assigned to the structure above the isolation system based on
ot nd E
10 

n
requirements of Section 12.3.4. The value of the redundancy factor, ρ, is permitted to be equal to
N U M
11 

12 
se li
1.0 for isolated structures that do not have a structural irregularity, as defined in Section 17.2.2.
M

17.2.4 Isolation System


D ut O

13 
C

14  17.2.4.1 Environmental Conditions.


e C
/

15  In addition to the requirements for vertical and lateral loads induced by wind and earthquake, the
rik LI

16  isolation system shall provide for other environmental conditions, including aging effects, creep,
17  fatigue, operating temperature, and exposure to moisture or damaging substances.
o
St B
PU

18  17.2.4.2 Wind Forces.


o

19  Isolated structures shall resist design wind loads at all levels above the isolation interface. At the
20  isolation interface, a wind-restraint system shall be provided to limit lateral displacement in the
21  isolation system to a value equal to that required between floors of the structure above the
22  isolation interface, in accordance with Section 17.5.6.

23  17.2.4.3 Fire Resistance.

7
1  Fire resistance for the isolation system shall provide at least the same degree of protection as the
2  fire resistance required for the columns, walls, or other such gravity-bearing elements in the
3  same region of the structure.

ite rm T
4  17.2.4.4 Lateral Restoring Force.

C Fo AF
5  The isolation system shall be configured, for both upper bound and lower bound isolation system

at
6  properties, to produce a restoring force such that the lateral force at the corresponding maximum

or e R
7  displacement is at least 0.025 W greater than the lateral force at 50% of the corresponding

D
8  maximum displacement.

U er NT
9  17.2.4.5 Displacement Restraint.

10  The isolation system shall not be configured to include a displacement restraint that limits lateral
ot nd E
n
11  displacement caused by risk-targeted maximum considered earthquake ( MCER ) ground motions
N U M

12 
se li
to less than the total maximum displacement, DTM , unless the seismically isolated structure is
M

13  designed in accordance with all of the following criteria:


D ut O

14  1. MCER response is calculated in accordance with the dynamic analysis requirements of
C

15  Section 17.6, explicitly considering the nonlinear characteristics of the isolation system
e C
/

16  and the structure above the isolation system.


2. The ultimate capacity of the isolation system and structural elements below the isolation
rik LI

17 

18  system shall exceed the strength and displacement demands of the MCER response.
o
St B

19  3. The structure above the isolation system is checked for stability and ductility demand of
PU

20  the MCER response.

21  4. The displacement restraint does not become effective at a displacement less than 0.6
22  times the total maximum displacement.

23  17.2.4.6 Vertical-Load Stability.

24  Each element of the isolation system shall be designed to be stable under the design vertical load
25  where it is subjected to a horizontal displacement equal to the total maximum displacement. The

8
1  design vertical load shall be computed using load combination 2 of Section 17.2.7.1 for the
2  maximum vertical load and load combination 3 of Section 17.2.7.1 for the minimum vertical
3  load.

ite rm T
4  17.2.4.7 Overturning.

C Fo AF
5  The factor of safety against global structural overturning at the isolation interface shall not be

at
6  less than 1.0 for required load combinations. All gravity and seismic loading conditions shall be

or e R
7  investigated. Seismic forces for overturning calculations shall be based on MCER ground

D
8  motions, and W shall be used for the vertical restoring force.

U er NT
9  Local uplift of individual elements shall not be allowed unless the resulting deflections do not
10  cause overstress or instability of the isolator units or other structure elements.
ot nd E
n
11  17.2.4.8 Inspection and Replacement.
N U M
se li
M

12  All of the following items shall be addressed as part of the long-term inspection and replacement
13  program:
D ut O

14  1. Access for inspection and replacement of all components of the isolation system shall be
C

15  provided.
e C

2. RA registered design professional (RDP) shall complete a final series of observations of


/

16 
17  structure separation areas and components that cross the isolation interface before the
rik LI

18  issuance of the certificate of occupancy for the seismically isolated structure. Such
o
St B

19  observations shall verify that conditions allow free and unhindered displacement of the
PU

20  structure up to the total maximum displacement and that components that cross the
o

21  isolation interface have been constructed to accommodate the total maximum
22  displacement.
23  3. Seismically isolated structures shall have a monitoring, inspection, and maintenance plan
24  for the isolation system established by the registered design professional responsible for
25  the design of the isolation system.

9
1  4. Remodeling, repair, or retrofitting at the isolation system interface, including that of
2  components that cross the isolation interface, shall be performed under the direction of a
3  registered design professional.

ite rm T
4  17.2.4.9 Quality Control.

C Fo AF
5  A quality control testing program for isolator units shall be established by the registered design

at
6  professional responsible for the structural design, incorporating the production testing

or e R
7  requirements of Section 17.8.5.

D
8  17.2.5 Structural System

U er NT
9  17.2.5.1 Horizontal Distribution of Force.
ot nd E
n
10  A horizontal diaphragm or other structural elements shall provide continuity above the isolation
N U M
11 
12 
se li
interface and shall have adequate strength and ductility to transmit forces from one part of the
structure to another.
M
D ut O

13  17.2.5.2 Minimum Building Separations.


C

14  Minimum separations between the isolated structure and surrounding retaining walls or other
15  fixed obstructions shall not be less than the total maximum displacement.
e C
/
rik LI

16  17.2.5.3 Nonbuilding Structures.


o
St B

17  Nonbuilding structures shall be designed and constructed in accordance with the requirements of
PU

18  Chapter 15 using design displacements and forces, calculated in accordance with Sections 17.5
o

19  or 17.6.

20  17.2.5.4 Steel Ordinary Concentrically Braced Frames.

21  Steel ordinary concentrically braced frames are permitted as the seismic force-resisting system in
22  seismically isolated structures assigned to Seismic Design Categoriesy D, E, and F and are
23  permitted to a height of 160 ft (48.4 m) or less, provided that all of the following design
24  requirements are satisfied:

10
1  1. The value of RI , as defined in Section 17.5.4 is 1.0.

2  2. The total maximum displacement ( DTM ), as defined in Eq.uation (17.5-3) shall be

3  increased by a factor of 1.2.

ite rm T
4  17.2.5.5 Isolation System Connections.

C Fo AF
at
5  Moment–resisting connections of structural steel elements of the seismic isolation system below

or e R
6  the base level are permitted to conform to the requirements for ordinary steel moment frames of

D
7  AISC 341, E1.6a and E1.6b.

U er NT
8  17.2.6 Elements of Structures and Nonstructural Components.

9  Parts or portions of an isolated structure, permanent nonstructural components and the


ot nd E
n
10  attachments to them, and the attachments for permanent equipment supported by a structure shall
N U M
11 
12 
se li
be designed to resist seismic forces and displacements, as prescribed by this section and the
applicable requirements of Chapter 13.
M
D ut O

13  17.2.6.1 Components at or above the Isolation Interface.


C

14  Elements of seismically isolated structures and nonstructural components, or portions thereof,
15  that which are at, or above, the isolation interface, shall be designed to resist a total lateral
e C
/

16  seismic force equal to the maximum dynamic response of the element or component under
rik LI

17  consideration, determined using a response history analysis.


o
St B

18  EXCEPTION: Elements of seismically isolated structures and nonstructural components or


PU

19  portions designed to resist seismic forces and displacements, as prescribed in Chapter 12 or 13 as
o

20  appropriate, are not required to meet this provision.

21  17.2.6.2 Components Crossing the Isolation Interface.

22  Elements of seismically isolated structures and nonstructural components, or portions thereof,
23  which that cross the isolation interface, shall be designed to withstand the total maximum
24  displacement and to accommodate, on a long-term basis, any permanent residual displacement.

11
1  17.2.6.3 Components below the Isolation Interface.

2  Elements of seismically isolated structures and nonstructural components, or portions thereof,


3  which that are below the isolation interface, shall be designed and constructed in accordance

ite rm T
4  with the requirements of Section 12.1 and Chapter 13.

C Fo AF
5  17.2.7 Seismic Load Effects and Load Combinations.

at
or e R
6  All members of the isolated structure, including those that are not part of the seismic force-

D
7  resisting system, shall be designed using the seismic load effects of Section 12.4, and the
8  additional load combinations of Section 17.2.7.1, for the design of the isolation system and for

U er NT
9  the testing of prototype isolator units.

10  17.2.7.1 Isolator Unit Vertical Load Combinations.


ot nd E
n
N U M
11  se li
The average, minimum, and maximum vertical load on each isolator unit type shall be computed

from application of horizontal seismic forces, QE , caused by MCER ground motions and the
M

12 

13  following applicable vertical load combinations:


D ut O

1. Average vertical load: load corresponding to 1.0 dead load plus 0.5 live load.
C

14 

15  2. Maximum vertical load: load combination 6 of Section 2.3.6, where E is given by
e C
/

16  Eq.uation (12.4-1) and 0.2 SDS is replaced by 0.12 SMS in Eq.uation (12.4-4a).
rik LI

17  3. Minimum vertical load: load combination 7 of Section 2.3.6, where E is given by
o
St B

18  Eq.uation (12.4-2) and 0.2 SDS is replaced by 0.12 SMS in Eq.uation (12.4-4a).
PU

19  17.2.8 Isolation System Properties

20  17.2.8.1 Isolation System Component Types.

21  All components of the isolation system shall be categorized and grouped in terms of common
22  type and size of isolator unit and common type and size of supplementary damping device, if
23  such devices are also components of the isolation system.

12
1  17.2.8.2 Isolator Unit Nominal Properties.

2  Isolator unit nominal design properties shall be based on average properties over the three cycles
3  of prototype testing, specified by Item 2 of Section 17.8.2.2. Variation in isolator unit properties

ite rm T
4  with vertical load are permitted to be established based on a single representative deformation

C Fo AF
5  cycle, by averaging the properties determined using the three vertical load combinations

at
6  specified in Section 17.2.7.1, at each displacement level, where required to be considered by
Section 17.8.2.2.

or e R

D
8  EXCEPTION: If the measured values of isolator unit effective stiffness and effective damping
9  for load combination 1 of Section 17.2.7.1 differ by less than 15% from the those based on the

U er NT
10  average of measured values for the three vertical load combinations of Section 17.2.7.1, then
11  nominal design properties are permitted to be computed only for load combination 1 of
ot nd E
12  Section 17.2.7.1.

n
N U M
13 
se li
17.2.8.3 Bounding Properties of Isolation System Components.
M

14  Bounding properties of isolation system components shall be developed for each isolation system
D ut O

15  component type. Bounding properties shall include variation in all of the following component
C

16  properties:

1. Measured by prototype testing, Item 2 of Section 17.8.2.2, considering variation in


e C

17 
/

18  prototype isolator unit properties caused by required variation in vertical test load, rate of
rik LI

19  test loading or velocity effects, effects of heating during cyclic motion, history of loading,
o
St B

20  scragging (temporary degradation of mechanical properties with repeated cycling), and
PU

21  other potential sources of variation measured by prototype testing,


o

22  2. Permitted by manufacturing specification tolerances used to determine acceptability of


23  production isolator units, as required by Section 17.8.5, and
24  3. Because of aging and environmental effects, including creep, fatigue, contamination,
25  operating temperature and duration of exposure to that temperature , and wear over the
26  life of the structure.

27  17.2.8.4 Property Modification Factors.

13
1  Maximum and minimum property modification ( λ) factors shall be used to account for the
2  variation of the nominal design parameters of each isolator unit type for the effects of heating
3  caused by cyclic dynamic motion, loading rate, scragging and recovery, variability in production
4  bearing properties, temperature, aging, environmental exposure, and contamination. When

ite rm T
5  manufacturer-specific qualification test data, in accordance with Section 17.8, have been

C Fo AF
6  approved by the registered design professional, these data are permitted to be used to develop the

at
7  property modification factors, and the maximum and minimum limits of Equations. (17.2-1) and

or e R
8  (17.2-2) need not apply. When qualification test data, in accordance with Section 17.8, have not

D
9  been approved by the registered design professional, the maximum and minimum limits of
10  Equations. (17.2-1) and (17.2-2) shall apply.

U er NT
11  Property modification factors ( λ) shall be developed for each isolator unit type, and when
12  applied to the nominal design parameters shall envelop the hysteretic response for the range of
ot nd E
n
13  demands from 0.5DM up to and including the maximum displacement,  DM . Property
N U M

14 
se li
modification factors for environmental conditions are permitted to be developed from data that
M

15  need not satisfy the similarity requirements of Section 17.8.2.7.


D ut O

16  For each isolator unit type, the maximum property modification factor, λmax , and the minimum
C

17  property modification factor, λmin , shall be established from contributing property modification
e C
/

18  factors in accordance with Equations. (17.2-1) and (17.2-2), respectively:


rik LI

λmax  (1 (0.75 (λ(ae,max) 1)))  λ(test,max) λ(spec,max)  1.8


19  (17.2-1)
o
St B
PU

λmin  (1 (0.75 (1 λ(ae,min) )))  λ(test,min) λ(spec,min)  0.60


o

20  (17.2-2)

21  where

22  λ(ae,max) = Pproperty modification factor for calculation of the maximum value of the isolator
23  property of interest, used to account for aging effects and environmental conditions;.

14
1  λ(ae,min) = Pproperty modification factor for calculation of the minimum value of the isolator
2  property of interest, used to account for aging effects and environmental conditions;.

3  λ(test,max) = Pproperty modification factor for calculation of the maximum value of the isolator

ite rm T
4  property of interest, used to account for heating, rate of loading, and scragging;.

C Fo AF
at
5  λ(test,min) = Pproperty modification factor for calculation of the minimum value of the isolator

or e R
6  property of interest, used to account for heating, rate of loading, and scragging;.

D
7  λ(spec,max) = Pproperty modification factor for calculation of the maximum value of the isolator

U er NT
8  property of interest, used to account for permissible manufacturing variation on the average
9  properties of a group of same-sized isolators; and.
ot nd E
n
10  λ(spec,min) = Pproperty modification factor for calculation of the minimum value of the isolator
N U M
11  se li
property of interest, used to account for permissible manufacturing variation on the average
M

12  properties of a group of same-sized isolators.


D ut O

13  EXCEPTION: If the prototype isolator testing is conducted on a full-scale specimen that
14  satisfies the dynamic test data of Section 17.8.2.3, then the values of the property modification
C

15  factors shall be based on the test data, and the upper and lower limits of Equations. (17.2-1) and
e C

(17.2-2) need not apply.


/

16 
rik LI

17  17.2.8.5 Upper Bound and Lower Bound Force-Deflection Behavior of Isolation System
o
St B

18  Components.
PU

19  A mathematical model of upper bound force-deflection (loop) behavior of each type of isolation
20  system component shall be developed. Upper bound force-deflection behavior of isolation
21  system components that are essentially hysteretic devices (e.g., isolator units) shall be modeled
22  using the maximum values of isolator properties calculated using the property modification
23  factors of Section 17.2.8.4. Upper bound force-deflection behavior of isolation system
24  components that are essentially viscous devices (e.g., supplementary viscous dampers) shall be
25  modeled in accordance with the requirements of Chapter 18 for such devices.

15
1  A mathematical model of lower bound force-deflection (loop) behavior of each type of isolation
2  system component shall be developed. Lower bound force-deflection behavior of isolation
3  system components that are essentially hysteretic devices (e.g., isolator units) shall be modeled
4  using the minimum values of isolator properties calculated using the property modification

ite rm T
5  factors of Section 17.2.8.4. Lower bound force-deflection behavior of isolation system

C Fo AF
6  components that are essentially viscous devices (e.g., supplementary viscous dampers) shall be

at
7  modeled in accordance with the requirements of Chapter 18 for such devices.

or e R
8  17.2.8.6 Isolation System Properties at Maximum Displacements.

D
9  The effective stiffness, kM , of the isolation system at the maximum displacement, DM , shall be

U er NT
10  computed using both upper bound and lower bound force-deflection behavior of individual
11  isolator units, in accordance with Eq.uation (17.2-3):
ot nd E
n
N U M
se li kM 
| F
M |   | FM |
2 DM
M

12  (17.2-3)
D ut O

13  The effective damping, βM , of the isolation system at the maximum displacement, DM , in inches
C

14  (mm), shall be computed using both upper bound and lower bound force-deflection behavior of
15  individual isolator units, in accordance with Eq.uation (17.2-4):
e C
/

E
rik LI

βM 
M

2πkM DM2 (17.2-4)


o

16 
St B
PU

17  where
o

18  E M = Ttotal energy dissipated [kips-in. (kN-mm)] in the isolation system during a full cycle of

19  response at the displacement DM ;.

20  F 
M = Ssum, for all isolator units, of the absolute value of force [kips (kN)] at a positive

21  displacement equal to DM ;.

16
1  F 
M = Ssum, for all isolator units, of the absolute value of force [kips (kN)] at a negative

2  displacement equal to DM ;.

3  17.2.8.7 Upper Bound and Lower Bound Isolation System Properties at Maximum

ite rm T
4  Displacement.

C Fo AF
at
5  The analysis of the isolation system and structure shall be performed separately for upper bound

or e R
6  and lower bound properties, and the governing case for each response parameter of interest shall

D
7  be used for design. In addition, the analysis shall comply with all of the following:

8  1. For the equivalent lateral force procedure, and for the purposes of establishing minimum

U er NT
9  forces and displacements for dynamic analysis, the following variables shall be calculated

10  independently for upper bound and lower bound isolation system properties: kM and βM
ot nd E
n
per Section 17.2.8.6 (Equations. (17.2-3) and (17.2-4)), DM per Section 17.5.3.1
N U M
11 

12 
se li(Equation. (17.5-1)), TM per Section 17.5.3.2 (Eq.uation (17.5-2)), DTM per
M

13  Section 17.5.3.3 (Eq.uation (17.5-3)), Vb per Section 17.5.4.1 (Eq.uation (17.5-5)), and
D ut O

14  Vs and Vst per Section 17.5.4.2 (Equations. (17.5-6) and (17.5-7)).
C

15  2. LThe limitations on Vs established in Section 17.5.4.3 shall be evaluated independently


e C
/

16  for both upper bound and lower bound isolation system properties, and the most adverse
rik LI

17  requirement shall govern.


o

3. For the equivalent lateral force procedure and for the purposes of establishing minimum
St B

18 
19  story shear forces for response spectrum analysis, the vertical force distribution from
PU

20  Section 17.5.5 shall be determined separately for upper bound and lower bound isolation

21  system properties. This determination will require independent calculation of F1 , Fx ,

22  Cvx , and k, per Equations. (17.5-8) through (17.5-11), respectively.

23  17.3 SEISMIC GROUND MOTION CRITERIAHAZARD

17
1  17.3.1 Spectral Response Acceleration Parameters and Response Spectrum . The MCER
2  spectral response acceleration parameters (SMS and SM1) and the MCER spectrum shall be
3  determined in accordance with Section 11.4.

17.3.2 Ground Motions for Response History Analysis. Where response history analysis in

ite rm T

accordance with Section 17.6.3.4 is used to design seismically isolated structures, the provisions

C Fo AF

of Section 16.2 shall apply except that in lieu of the requirements of Section 16.2.3.1, the period

at

7  range shall be determined in accordance with the following:

or e R D
8  A period range shall be determined , corresponding to the vibration periods that
9  significantly contribute to the structure’s lateral dynamic response. The upper bound of this

U er NT
10  period range shall be greater than or equal to 1.25TM, as determined using lower bound isolation
11  system properties. The lower bound period of this period range shall be established such that the
ot nd E
12  period range includes at least the number of modes necessary to achieve 90% mass participation

n
N U M
13  in each principal horizontal direction and shall not exceed Tfb. Where vertical response is
14 
se li
considered in the analysis, the lower bound period of the period range used for the modification
M

15  of vertical components of ground motion need not be taken as less than the larger of 0.1 seconds
D ut O

16  or the lowest period at which significant vertical mass participation occurs.17.3.1 Site-Specific
17  Seismic Hazard.
C

The MCER response spectrum requirements of Sections 11.4.5 and 11.4.6 are permitted to be
e C

18 
/

used to determine the MCER response spectrum for the site of interest. The site-specific ground
rik LI

19 

motion procedures set forth in Chapter 21 are also permitted to be used to determine ground
o

20 
St B

21  motions for any isolated structure. For isolated structures on Site Class F sites, site response
PU

22  analysis shall be performed in accordance with Section 21.1.

23  17.3.2 MCER Response Spectra and Spectral Response Acceleration Parameters, SMS , SM1 .

24  The MCER response spectrum shall be the MCER response spectrum of Sections 11.4.6, or

25  11.4.7. The MCER response spectral acceleration parameters SMS and SM1 shall be determined

26  in accordance with Section 11.4.4 or 11.4.8.

18
1  17.3.3 MCER Ground Motion Records.

2  Where response history analysis procedures are used, MCER ground motions shall consist of not

3  less than seven pairs of horizontal acceleration components selected and scaled from individual

ite rm T
4  recorded events that have magnitudes, fault distances, and source mechanisms that are consistent

C Fo AF
with those that control the MCER . Amplitude or spectral matching is permitted to scale the

at

ground motions. Where the required number of recorded ground motion pairs is not available,

or e R

7  simulated ground motion pairs are permitted to make up the total number required.

D
8  For each pair of horizontal ground motion components, a square root of the sum of the squares

U er NT
9  (SRSS) spectrum shall be constructed by taking the SRSS of the 5%-damped response sctra for
10  the scaled components (when amplitude scaling is used, an identical scale factor is applied to
ot nd E
11  both components of a pair). Each pair of motions shall be scaled such that in the period range

n
N U M
12  from 0.75TM , determined using upper bound isolation system properties, to 1.25TM , determined
se li
using lower bound isolation system properties, the average of the SRSS spectra from all
M

13 
14  horizontal component pairs does not fall below the corresponding ordinate of the response
D ut O

15  spectrum used in the design ( MCER ), determined in accordance with Section 11.4.6 or 11.4.7.
C

16  For records that are spectrally matched, each pair of motions shall be scaled such that in the
e C
/

17  period range from 0.2TM , determined using upper bound properties, to 1.25TM , determined using
rik LI

18  lower bound properties, the response spectrum of one component of the pair is at least 90% of
o
St B

19  the corresponding ordinate of the response spectrum used in the design determined in accordance
with Section 11.4.6 or 11.4.7.
PU

20 
o

21  For sites within 3 mi (5 km) of the active fault that controls the hazard, spectral matching shall
22  not be used unless the pulse characteristics of the near-field ground motions are included in the
23  site-specific response spectra, and pulse characteristics, when present in individual ground
24  motions, are retained after the matching process has been completed.

25  At sites within 3 mi (5 km) of the active fault that controls the hazard, each pair of components
26  shall be rotated to the fault-normal and fault-parallel directions of the causative fault and shall be

19
1  scaled so that the average spectrum of the fault-normal components is not less than the MCER

2  spectrum and the average spectrum of the fault-parallel components is not less than 50% of the

3  MCER response spectrum for the period range 0.2TM , determined using upper bound properties,

ite rm T
4  to 1.25TM , determined using lower bound properties.

C Fo AF
at
5  17.4 ANALYSIS PROCEDURE SELECTION

or e R
6  Seismically isolated structures, except those defined in Section 17.4.1, shall be designed using

D
7  the dynamic procedures of Section 17.6. Where supplementary viscous dampers are used, the
8  response history analysis procedures of Section 17.4.2.2 shall be used.

U er NT
17.4.1 Equivalent Lateral Force Procedure.
ot nd E
n
10  The equivalent lateral force procedure of Section 17.5 is permitted to be used for design of a
N U M
11 
se li
seismically isolated structure provided that all of the following items are satisfied. These
M

12  requirements shall be evaluated separately for upper bound and lower bound isolation system
13  properties, and the more restrictive requirement shall govern.
D ut O C

14  1. The structure is located on a Site Class A, B, C, or D site.

15  2. The effective period of the isolated structure at the maximum displacement, DM , is less
e C
/

16  than, or equal to, 5.0 s.


rik LI

17  3. The structure above the isolation interface is less than or equal to four stories, or 65 ft
o
St B

18  (19.8 m) in structural height measured from the base level.


19  EXCEPTION: These limits are permitted to be exceeded if there is no tension or
PU

20  uplift on the isolators.

21  4. The effective damping of the isolation system at the maximum displacement, DM , is less
22  than or equal to 30%.

23  5. The effective period of the isolated structure TM is greater than three times the elastic,
24  fixed-base period of the structure above the isolation system, determined using a rational
25  modal analysis.

20
1  6. The structure above the isolation system does not have a structural irregularity, as defined
2  in Section 17.2.2.
3  7. The isolation system meets all of the following criteria:
4  (a) The effective stiffness of the isolation system at the maximum displacement is

ite rm T
5  greater than one-third of the effective stiffness at 20% of the maximum

C Fo AF
6  displacement.

at
7  (b) The isolation system is capable of producing a restoring force, as specified in

or e R
8  Section 17.2.4.4.
(c) The isolation system does not limit maximum earthquake displacement to less

D

10  than the total maximum displacement, DTM .

11 

U er NT
17.4.2 Dynamic Procedures.
ot nd E
n
12  The dynamic procedures of Section 17.6 are permitted to be used as specified in this section.
N U M

13 
se li
17.4.2.1 Response Spectrum Analysis Procedure.
M
D ut O

14  Response spectrum analysis procedure shall not be used for design of a seismically isolated
15  structure unless the structure, site, and isolation system meet the criteria of Section 17.4.1, Items
C

16  1, 2, 3, 4, and 6.
e C
/

17  17.4.2.2 Response History Analysis Procedure.


rik LI

The response history analysis procedure is permitted to be used for design of any seismically
o

18 
St B

19  isolated structure and shall be used for design of all seismically isolated structures not meeting
PU

the criteria of Section 17.4.2.1.


o

20 

21  17.5 EQUIVALENT LATERAL FORCE PROCEDURE

22  17.5.1 General.

23  Where the equivalent lateral force procedure is used to design seismically isolated structures, the
24  requirements of this section shall apply.

21
1  17.5.2 Deformation Characteristics of the Isolation System.

2  Minimum lateral earthquake design displacements, and forces on seismically isolated structures,
3  shall be based on the deformation characteristics of the isolation system. The deformation

ite rm T
4  characteristics of the isolation system include the effects of the wind-restraint system if such a

C Fo AF
5  system is used to meet the design requirements of this standard. The deformation characteristics

at
6  of the isolation system shall be based on properly substantiated prototype tests performed in
accordance with Section 17.8, and shall incorporate property modification factors in accordance

or e R

8  with Section 17.2.8.4.

D
9  The analysis of the isolation system and structure shall be performed separately for upper bound

U er NT
10  and lower bound properties, and the governing case for each response parameter of interest shall
11  be used for design.
ot nd E
n
12  17.5.3 Minimum Lateral Displacements Required for Design
N U M
se li
17.5.3.1 Maximum Displacement.
M

13 
D ut O

14  The isolation system shall be designed and constructed to withstand, at a minimum, the
C

15  maximum displacement, DM , determined using upper bound and lower bound properties, in the
16  most critical direction of horizontal response, calculated using Equation. (17.5-1):
e C
/
rik LI

gSM 1TM
17  DM  (17.5-1)
4π2 BM
o
St B
PU

18  where
o

19  g = Aacceleration caused by gravity [ in. / s 2 ( mm / s 2 )] if the units of the displacement DM are in
20  in. (mm);

21  SM1 = MCER 5% damped spectral acceleration parameter at 1-s period in units of g-sec, as
22  determined in Section 11.4.4 or 11.4.8;

22
1  TM = Eeffective period of the seismically isolated structure [s] at the displacement DM in the
2  direction under consideration, as prescribed by Equation. (17.5-2); and

3  BM = Nnumerical coefficient as set forth in Table 17.5-1 for the effective damping of the

ite rm T
4  isolation system βM at the displacement DM .

C Fo AF
at
5  Table 17.5-1. Damping Factor, BM .

or e R D
Effective Damping, β M (percentage of critical)a,b BM Factor
2 0.8

U er NT
5 1.0
10 1.2
ot nd E
n
20 1.5
N U M
30 se li 1.7
M

40 1.9
 50 2.0
D ut O

6  a
The damping factor shall be based on the effective damping of the isolation system, determined
C

7  in accordance with the requirements of Section 17.2.8.6.


e C

The damping factor shall be based on linear interpolation for effective damping values other
/

b

9  than those given.
rik LI
o
St B

10  17.5.3.2 Effective Period at the Maximum Displacement. T he effective period of the isolated
PU

11  structure, TM , at the maximum displacement, DM , shall be determined using upper bound and
o

12  lower bound deformational characteristics of the isolation system and Equation. (17.5-2):

W
TM  2π
kM g
13  (17.5-2)

14  where

23
1  W = Eeffective seismic weight of the structure above the isolation interface as defined in
2  Section 12.7.2;

3  kM = Eeffective stiffness [ kip / in. ( kN / mm )] of the isolation system at the maximum

ite rm T
4  displacement, DM , as prescribed by Equation. (17.2-3); and

C Fo AF
at
5  g = Aacceleration caused by gravity [ in. / s 2 ( mm / s 2 )] if the units of kM are in kip / in. ( kN / mm

or e R
6  ).

D
7  17.5.3.3 Total Maximum Displacement.

U er NT
8  The total maximum displacement, DTM , of elements of the isolation system shall include
additional displacement caused by actual and accidental torsion, calculated from the spatial
ot nd E

n
10  distribution of the lateral stiffness of the isolation system and the most disadvantageous location
N U M

11 
se li
of eccentric mass. The total maximum displacement, DTM , of elements of an isolation system
M

12  shall not be taken as less than that prescribed by Equation. (17.5-3):
D ut O

  y  12e 
C

DTM  DM 1   2  2 2
13    PT  b  d  (17.5-3)
e C
/

where
rik LI

14 
o
St B

15  DM = Ddisplacement at the center of rigidity of the isolation system in the direction under
PU

16  consideration, as prescribed by Equation. (17.5-1);


o

17  y = Dthe distance [in. (mm)] between the centers of rigidity of the isolation system and the
18  element of interest measured perpendicular to the direction of seismic loading under
19  consideration;

20  e = Athe actual eccentricity measured in plan between the center of mass of the structure above
21  the isolation interface and the center of rigidity of the isolation system, plus accidental

24
1  eccentricity [ft (mm)], taken as 5% of the longest plan dimension of the structure perpendicular
2  to the direction of force under consideration;

3  b = Sthe shortest plan dimension of the structure [ft (mm)] measured perpendicular to d;

ite rm T
4  d = Lthe longest plan dimension of the structure [ft (mm)]; and

C Fo AF
at
5  PT = Rratio of the effective translational period of the isolation system to the effective torsional

or e R
6  period of the isolation system, as calculated by dynamic analysis, or as prescribed by
7  Equation. (17.5-4) but need not be taken as less than 1.0.

D
i 1

U er NT
1 ( x 2
i  yi2 )
PT  N


rI N (17.5-4)
ot nd E
n
N U M
9  se li
where
M

10  xi , yi = Hhorizontal distances [ft (mm)] from the center of mass to the i th isolator unit in the
D ut O

11  two horizontal axes of the isolation system;


C

12  N = Nnumber of isolator units;


e C
/

13  rI = Rradius of gyration of the isolation system [ft (mm)], which is equal to ( (b2  d2 )/12)1/2 for
rik LI

14  isolation systems of rectangular plan dimension, b  d .


o
St B

15  The total maximum displacement, DTM , shall not be taken as less than 1.15 times DM .
PU

16  17.5.4 Minimum Lateral Forces Required for Design

17  17.5.4.1 Isolation System and Structural Elements below the Base Level.

18  The isolation system, the foundation, and all structural elements below the base level shall be

19  designed and constructed to withstand a minimum lateral seismic force, Vb , using all of the
20  applicable requirements for a nonisolated structure, as prescribed by the value of

25
1  Equation. (17.5-5), determined using both upper bound and lower bound isolation system
2  properties:

Vb  kM DM
3  (17.5-5)

ite rm T
C Fo AF
4  where

at
5  kM = Eeffective stiffness [ kip / in. ( kN / mm )] of the isolation system at the displacemen t DM , as

or e R
6  prescribed by Equation. (17.2-3) and,

D
7  DM = Mmaximum displacement [in. (mm)] at the center of rigidity of the isolation system in the

U er NT
8  direction under consideration, as prescribed by Eq.uation (17.5-1).
ot nd E
Vb shall not be taken as less than the maximum force in the isolation system at any displacement

n

N U M
10  se li
up to and including the maximum displacement DM , as defined in Section 17.5.3
M

11  Overturning loads on elements of the isolation system, the foundation, and structural elements
D ut O

12  below the base level caused by lateral seismic force Vb shall be based on the vertical distribution
C

13  of force of Section 17.5.5, except that the unreduced lateral seismic design force Vst shall be used
e C
/

14  in lieu of Vs in Eq.uation (17.5-9).


rik LI

15  17.5.4.2 Structural Elements above the Base Level.


o
St B
PU

16  The structure above the base level shall be designed and constructed using all of the applicable
o

17  requirements for a nonisolated structure for a minimum shear force, Vs , determined using upper
18  bound and lower bound isolation system properties, as prescribed by Eq.uation (17.5-6):

Vst
Vs 
19 
RI (17.5-6)

20  where

26
1  RI = Nnumerical coefficient related to the type of seismic force-resisting system above the
2  isolation system,; and

3  Vst = Ttotal unreduced lateral seismic design force or shear on elements above the base level, as

ite rm T
4  prescribed by Eq.uation (17.5-7).

C Fo AF
at
5  The RI factor shall be based on the type of seismic force-resisting system used for the structure

or e R
6  above the base level in the direction of interest and shall be three-eighths of the value of R

D
7  given in Table 12.2-1, with a maximum value not greater than 2.0 and a minimum value not less
8  than 1.0.

U er NT
9  EXCEPTION: The value of Ri is permitted to be taken as greater than 2.0, provided the
ot nd E
10  strength of the structure above the base level in the direction of interest, as determined by

n
nonlinear static analysis at a roof displacement corresponding to a maximum story drift the lesser
N U M
11 

12 
se li
of the MCER drift or 0.015hsx , is not less than 1.1 times Vb .
M

The total unreduced lateral seismic force or shear on elements above the base level shall be
D ut O

13 
14  determined using upper bound and lower bound isolation system properties, as prescribed by
C

15  Eq.uation (17.5-7):


e C
/

(1 2.5βm )
W 
Vst  Vb  s 
rik LI

16  W  (17.5-7)
o
St B

17  where
PU

18  W = Eeffective seismic weight [kips (kN)] of the structure above the isolation interface, as
19  defined in Section 12.7.2; and

20  Ws = Eeffective seismic weight [kips (kN)] of the structure above the isolation interface, as
21  defined in Section 12.7.2, excluding the effective seismic weight [kips (kN)] of the base level.

27
1  The effective seismic weight Ws in Eq.uation (17.5-7) shall be taken as equal to W when the

2  average distance from the top of the isolator to the underside of the base level floor framing
3  above the isolators exceeds 3 ft (0.9 m).

ite rm T
4  EXCEPTION: For isolation systems whose hysteretic behavior is characterized by an abrupt

C Fo AF
5  transition from preyield to postyield or preslip to postslip behavior, the exponent term ( 12.5βM )

at
6  in Eq.uation (17.5-7) shall be replaced by ( 13.5βM ).

or e R D
7  17.5.4.3 Limits on Vs .

U er NT
8  The value of
ot nd E Vs shall not be taken as less than each of the following:

1. The lateral seismic force required by Section 12.8 for a fixed-base structure of the same

n

N U M
10  se li
effective seismic weight, Ws , and a period equal to the period of the isolation system
M

11  using the upper bound properties TM ;


D ut O

12  2. The base shear corresponding to the factored design wind load; and

3. The lateral seismic force, Vst , calculated using Eq.uation (17.5-7), and with Vb set equal
C

13 

14  to the force required to fully activate the isolation system using the greater of the upper
e C
/

15  bound properties, or


rik LI

16  (a) 1.5 times the nominal properties for the yield level of a softening system,
17  (b) The ultimate capacity of a sacrificial wind-restraint system,
o
St B

18  (c) The breakaway friction force of a sliding system, or


PU

(d) The force at zero displacement of a sliding system following a complete dynamic
o

19 

20  cycle of motion at DM .

21  17.5.5 Vertical Distribution of Force.

22  The lateral seismic force, Vs , shall be distributed over the height of the structure above the base
23  level, using upper bound and lower bound isolation system properties, using the following
24  equations:

28
(Vb  Vst )
F1 

RI (17.5-8)

2  and

ite rm T
Fx  CvxVs

C Fo AF
3  (17.5-9)

at
and

or e R

D
wx hxk
5  C vx  n
(17.5-10)
wh k

U er NT
i i
i2

6  and
ot nd E
n
N U M
7  se li k 14βMTfb (17.5-11)
M

8  where
D ut O

F1 = Llateral seismic force [kips (kN)] induced at level 1, the base level;
C


e C

Fx = Llateral seismic force [kips (kN)] induced at level x , x  1 ;


/

10 
rik LI

11  Cvx = Vvertical distribution factor;


o
St B
PU

12  Vs = Ttotal lateral seismic design force or shear on elements above the base level, as prescribed
o

13  by Eq.uation (17.5-6) and the limits of Section 17.5.4.3;

14  wi wx = Pportion of Ws that is located at or assigned to level i or x ;

15  hi hx = Hheight above the isolation interface of level i or x ; and

29
1  Tfb = Fthe fundamental period, in s, of the structure above the isolation interface determined
2  using a rational modal analysis assuming fixed-base conditions.

3  EXCEPTION: In lieu of Equations. (17.5-6) and (17.5-9), the lateral seismic force Fx is

ite rm T
4  permitted to be calculated as the average value of the force at level x in the direction of interest,

C Fo AF
5  using the results of a simplified stick model of the building and a lumped representation of the

at
6  isolation system using response history analysis scaled to Vb / RI at the base level.

or e R D
7  17.5.6 Drift Limits.

U er NT
8  The maximum story drift of the structure above the isolation system shall not exceed 0.015hsx .

9  The drift shall be calculated by Equation. (12.8-15) with Cd for the isolated structure equal to RI
ot nd E
n
10  , as defined in Section 17.5.4.2.
N U M
se li
17.6 DYNAMIC ANALYSIS PROCEDURES
M

11 
D ut O

12  17.6.1 General.


C

13  Where dynamic analysis is used to design seismically isolated structures, the requirements of this
14  section shall apply.
e C
/
rik LI

15  17.6.2 Modeling.


o
St B

16  The mathematical models of the isolated structure, including the isolation system, the seismic
PU

17  force-resisting system, and other structural elements, shall conform to Section 12.7.3 and to the
o

18  requirements of Sections 17.6.2.1 and 17.6.2.2.

19  17.6.2.1 Isolation System.

20  The isolation system shall be modeled using deformational characteristics developed in
21  accordance with Section 17.2.8. The lateral displacements and forces shall be computed
22  separately for upper bound and lower bound isolation system properties, as defined in

30
1  Section 17.2.8.5. The isolation system shall be modeled with sufficient detail to capture all of the
2  following:

3  1. Spatial distribution of isolator units;.


2. Translation, in both horizontal directions, and torsion of the structure above the isolation

ite rm T

interface considering the most disadvantageous location of eccentric mass;.

C Fo AF

3. Overturning and uplift forces on individual isolator units; and.

at

7  4. Effects of vertical load, bilateral load, and/or the rate of loading if the force-deflection

or e R
8  properties of the isolation system are dependent on one or more of these attributes.

D
9  The total maximum displacement, DTM , across the isolation system shall be calculated using a

U er NT
10  model of the isolated structure that incorporates the force-deflection characteristics of nonlinear
11  elements of the isolation system and the seismic force-resisting system.
ot nd E
n
12  17.6.2.2 Isolated Structure.
N U M

13 
se li
The maximum displacement of each floor and design forces and displacements in elements of the
M

14  seismic force-resisting system are permitted to be calculated using a linear elastic model of the
D ut O

15  isolated structure, provided that all elements of the seismic force-resisting system of the structure
above the isolation system remain essentially elastic.
C

16 

17  Seismic force-resisting systems with essentially elastic elements include, but are not limited to,
e C
/

18  regular structural systems designed for a lateral force not less than 100% of Vs determined in
rik LI

19  accordance with Sections 17.5.4.2 and 17.5.4.3.


o
St B

20  The analysis of the isolation system and structure shall be performed separately for upper bound
PU

21  and lower bound properties, and the governing case for each response parameter of interest shall
22  be used for design.

23  17.6.3 Description of Procedures

24  17.6.3.1 General.

31
1  Response spectrum analysis shall be performed, in accordance with Section 12.9 and the
2  requirements of Section 17.6.3.3. Response history analysis shall be performed, in accordance
3  with the requirements of Section 17.6.3.4.

ite rm T
4  17.6.3.2 MCER Ground Motions.

C Fo AF
at
5  The MCER ground motions of Section 17.3 shall be used to calculate the lateral forces and

or e R
6  displacements in the isolated structure, the total maximum displacement of the isolation system,

D
7  and the forces in the isolator units, isolator unit connections, and supporting framing
8  immediately above and below the isolators used to resist isolator P-delta demands.

U er NT
9  17.6.3.3 Response Spectrum Analysis Procedure.
ot nd E
n
10  Response spectrum analysis shall be performed using a modal damping value for the
N U M
11  se li
fundamental mode in the direction of interest not greater than the effective damping of the
isolation system or 30% of critical, whichever is less. Modal damping values for higher modes
M

12 
13  shall be selected consistent with those that would be appropriate for response spectrum analysis
D ut O

14  of the structure above the isolation system assuming a fixed base.
C

15  Response spectrum analysis used to determine the total maximum displacement shall include
simultaneous excitation of the model by 100% of the ground motion in the critical direction and
e C

16 
/

17  30% of the ground motion in the perpendicular, horizontal direction. The maximum
rik LI

18  displacement of the isolation system shall be calculated as the vector sum of the two orthogonal
o
St B

19  displacements.
PU

20  17.6.3.4 Response History Analysis Procedure.

21  Response history analysis shall be performed for a set of ground motion pairs selected and scaled
22  in accordance with Section 17.3.32. Each pair of ground motion components shall be applied
23  simultaneously to the model, considering the most disadvantageous location of eccentric mass.
24  The maximum displacement of the isolation system shall be calculated from the vector sum of
25  the two orthogonal displacements at each time step.

32
1  The parameters of interest shall be calculated for each ground motion used for the response
2  history analysis, and the average value of the response parameter of interest shall be used for
3  design.

For sites identified as near-fault, each pair of horizontal ground motion components shall be

ite rm T

rotated to the fault-normal and fault-parallel directions of the causative faults and applied to the

C Fo AF

building in such orientation.

at

or e R
7  For all other sites, individual pairs of horizontal ground motion components need not be applied
in multiple orientations.

D

9  17.6.3.4.1 Accidental Mass Eccentricity. Torsional response resulting from lack of symmetry in

U er NT
10  mass and stiffness shall be accounted for in the analysis. In addition, accidental eccentricity
11  consisting of displacement of the center of mass from the computed location by an amount equal
ot nd E
n
12  to 5% of the diaphragm dimension, shall be considered separately in each of two orthogonal
N U M
13  se li
directions at the level under consideration.
M

14  The effects of accidental eccentricity are permitted to be accounted for by amplifying forces,
drifts, and deformations determined from an analysis, using only the computed center of mass,
D ut O

15 
16  provided that factors used to amplify forces, drifts, and deformations of the center-of-mass
C

17  analysis are shown to produce results that bound all the mass-eccentric cases.
e C
/

18  17.6.4 Minimum Lateral Displacements and Forces


rik LI

19  17.6.4.1 Isolation System and Structural Elements below the Base Level.
o
St B
PU

20  The isolation system, foundation, and all structural elements below the base level shall be
o

21  designed using all of the applicable requirements for a nonisolated structure and the forces
22  obtained from the dynamic analysis without reduction, but the design lateral force shall not be

23  taken as less than 90% of Vb determined by Eq.uation (17.5-5).

24  The total maximum displacement of the isolation system shall not be taken as less than 80% of

25  DTM , as prescribed by Section 17.5.3.3, except that DM is permitted to be used in lieu of DM
26  where

33
DM
DM 
1  (T / TM ) 2
1  (17.6-1)

2  and

ite rm T
DM = Mmaximum displacement [in. (mm)] at the center of rigidity of the isolation system in the

C Fo AF

at
4  direction under consideration, as prescribed by Eq.uation (17.5-1);

or e R
5  T = Eelastic, fixed-base period, in s, of the structure above the isolation system, as determined by

D
6  Section 12.8.2, including the coefficient Cu , if the approximate period formulas are used to
calculate the fundamental period; and

U er NT

8  TM = Eeffective period, in s, of the seismically isolated structure, at the displacement DM in the


ot nd E
n
9  direction under consideration, as prescribed by Eq.uation (17.5-2).
N U M

10 
se li
17.6.4.2 Structural Elements above the Base Level.
M

Subject to the procedure-specific limits of this section, structural elements above the base level
D ut O

11 
12  shall be designed using the applicable requirements for a nonisolated structure and the forces
C

13  obtained from the dynamic analysis reduced by a factor of RI , as determined in accordance with
e C
/

14  Section 17.5.4.2.


rik LI

15  For response spectrum analysis, the design shear at any story shall not be less than the story
o
St B

16  shear resulting from application of the forces calculated using Eq.uation (17.5-9) and a value of
PU

17  Vb equal to the base shear obtained from the response spectrum analysis in the direction of
o

18  interest.

19  For response history analysis of regular structures, the value of Vb shall not be taken as less than

20  80% of that determined in accordance with Section 17.5.4.1, and the value Vs shall not be taken
21  as less than 100% of the limits specified by Section 17.5.4.3.

34
1  For response history analysis of irregular structures, the value of Vb shall not be taken as less

2  than 100% of that determined in accordance with Section 17.5.4.1, and the value Vs shall not be
3  taken as less than 100% of the limits specified by Section 17.5.4.3.

ite rm T
4  17.6.4.3 Scaling of Results.

C Fo AF
at
5  Where the factored lateral shear force on structural elements, determined using either the

or e R
6  response spectrum or response history procedure, is less than the minimum values prescribed by

D
7  Sections 17.6.4.1 and 17.6.4.2, all design parameters shall be adjusted upward proportionally.

U er NT
8  17.6.4.4 Drift Limits.

9  Maximum story drift corresponding to the design lateral force, including displacement caused by
ot nd E
n
10  vertical deformation of the isolation system, shall comply with either of the following limits:
N U M

11 
se li
1. Where response spectrum analysis is used, the maximum story drift of the structure above
M

12  the isolation system shall not exceed 0.015hsx .


D ut O

13  2. Where response history analysis based on the force-deflection characteristics of nonlinear
C

14  elements of the seismic force-resisting system is used, the maximum story drift of the

15  structure above the isolation system shall not exceed 0.020hsx .
e C
/

16  Drift shall be calculated using Eq.uation (12.8-15), with the Cd of the isolated structure equal to
rik LI

17  RI as defined in Section 17.5.4.2.


o
St B
PU

18  The secondary effects of the maximum lateral displacement of the structure above the isolation
o

19  system, combined with gravity forces, shall be investigated if the story drift ratio exceeds

20  0.010/ RI .

21  17.7 DESIGN REVIEW

22  An independent design review of the isolation system and related test programs shall be
23  performed by one or more individuals possessing knowledge of the following items, with a

35
1  minimum of one reviewer being a registered design professional (RDP). Isolation system design
2  review shall include, but not be limited to, all of the following:

3  1. Project design criteria, including site-specific spectra and ground motion histories.
2. Preliminary design, including the selection of the devices, determination of the maximum

ite rm T

displacement, the total maximum displacement, and the lateral force level.

C Fo AF

3. Review of qualification data and appropriate property modification factors for the

at

7  manufacturer and device selected.

or e R
8  4. Prototype testing program (Section 17.8.2).

D
9  5. Final design of the entire structural system and all supporting analyses, including
10  modeling of isolators for response history analysis, if performed.

U er NT
11  6. Isolator production testing program (Section 17.8.5).
ot nd E
12  17.8 TESTING

n
N U M
13 
se li
17.8.1 General.
M

14  The deformation characteristics and damping values of the isolation system used in the design
D ut O

15  and analysis of seismically isolated structures shall be based on tests of a selected sample of the
C

16  components before construction, as described in this section. The isolation system components to
17  be tested shall include the wind-restraint system if such a system is used in the design.
e C
/

18  The tests specified in this section are for establishing and validating the isolator unit and
rik LI

19  isolation system test properties that are used to determine design properties of the isolation
o
St B

20  system, in accordance with Section 17.2.8.


PU

21  17.8.1.1 Qualification Tests.

22  Isolation device manufacturers shall submit, for approval by the registered design professional,
23  the results of qualification tests, analysis of test data, and supporting scientific studies that are
24  permitted to be used to quantify the effects of heating caused by cyclic dynamic motion, loading
25  rate, scragging, variability and uncertainty in production bearing properties, temperature, aging,
26  environmental exposure, and contamination. The qualification testing shall be applicable to the
27  component types, models, materials, and sizes to be used in the construction. The qualification

36
1  testing shall have been performed on components manufactured by the same manufacturer
2  supplying the components to be used in the construction. When scaled specimens are used in the
3  qualification testing, principles of scaling and similarity shall be used in the interpretation of the
4  data.

ite rm T
C Fo AF
5  17.8.2 Prototype Tests.

at
6  Prototype tests shall be performed separately on two full-size specimens (or sets of specimens, as

or e R
7  appropriate) of each predominant type and size of isolator unit of the isolation system. The test

D
8  specimens shall include the wind-restraint system if such a system is used in the design.
9  Specimens tested shall not be used for construction unless they are accepted by the registered

U er NT
10  design professional responsible for the design of the structure.
ot nd E
11  17.8.2.1 Record.

n
N U M
12  se li
For each cycle of each test, the force-deflection behavior of the test specimen shall be recorded.
M

13  17.8.2.2 Sequence and Cycles.


D ut O

14  Each of the following sequence of tests shall be performed for the prescribed number of cycles,
C

15  at a vertical load equal to the average dead load plus one-half the effects caused by live load on
e C

all isolator units of a common type and size. Before these tests, the production set of tests
/

16 
17  specified in Section 17.8.5 shall be performed on each isolator:
rik LI
o

18  1. Twenty fully reversed cycles of loading at a lateral force corresponding to the wind
St B

19  design force.


PU

20  2. The sequence of either item (a) or item (b) below shall be performed:
21  (a) Three fully reversed cycles of loading at each of the following increments of the

0.25DM 0.5DM 0.67DM 1.0DM DM


22  displacement: , , , and , where is determined
23  in Section 17.5.3.1 or Section 17.6, as appropriate.

24  (b) The following sequence, performed dynamically at the effective period, TM :
25  continuous loading of one fully reversed cycle at each of the following increments

37
1  of the maximum displacement: 1.0DM , 0.67DM , 0.5DM , and 0.25DM followed

2  by continuous loading of one fully reversed cycle at 0.25DM , 0.5DM , 0.67DM ,

3  and 1.0DM . A rest interval is permitted between these two sequences.

ite rm T
4  3. Three fully reversed cycles of loading at the maximum displacement, 1.0DM .

C Fo AF
at
5  4. The sequence of either item (a) or item (b) below shall be performed:

(a) 30SM1 /(SMS BM ) , but not fewer than 10, continuous fully reversed cycles of

or e R

0.75DM .

D
7  loading at 0.75 times the maximum displacement,

8  (b) The test of Iitem (a), performed dynamically at the effective period, TM . This test

U er NT
9  may comprise separate sets of multiple cycles of loading, with each set consisting
10  of not fewer than five continuous cycles.
ot nd E
n
11  If an isolator unit is also a vertical load-carrying element, then item 3 of the sequence of cyclic
N U M
12  se li
tests specified in the preceding text shall be performed for two additional vertical load cases
M

13  specified in Section 17.2.7.1. The load increment caused by earthquake overturning, QE , shall be
D ut O

14  equal to or greater than the peak earthquake vertical force response corresponding to the test
15  displacement being evaluated. In these tests, the combined vertical load shall be taken as the
C

16  typical or average downward force on all isolator units of a common type and size. Axial load
e C

and displacement values for each test shall be the greater of those determined by analysis using
/

17 
18  upper bound and lower bound values of isolation system properties, determined in accordance
rik LI

19  with Section 17.2.8.5. The effective period TM shall be the lower of those determined by analysis
o
St B

20  using upper bound and lower bound values.


PU

21  17.8.2.3 Dynamic Testing.

22  Tests specified in Section 17.8.2.2 shall be performed dynamically at the lower of the effective

23  periods, TM , determined using upper bound and lower bound properties.

24  Dynamic testing shall not be required if the prototype testing has been performed dynamically on
25  similar-sized isolators that meet the requirements of Section 17.8.2.7, and the testing was

38
1  conducted at similar loads and accounted for the effects of velocity, amplitude of displacement,
2  and heating effects. The prior dynamic prototype test data shall be used to establish factors that

3  adjust three-cycle average values of kd and Eloop to account for the difference in test velocity and

heating effects and to establish λ(test,min) and λ(test,max) .

ite rm T

C Fo AF
5  Only if full-scale testing is not possible, reduced-scale prototype specimens can be used to

at
6  quantify rate-dependent properties of isolators. The reduced-scale prototype specimens shall be

or e R
7  of the same type and material and shall be manufactured with the same processes and quality as

D
8  full-scale prototypes and shall be tested at a frequency that represents full-scale prototype
9  loading rates.

U er NT
10  17.8.2.4 Units Dependent on Bilateral Load.
ot nd E
n
11  If the force-deflection properties of the isolator units exhibit bilateral load dependence, the tests
N U M
12  se li
specified in Sections 17.8.2.2 and 17.8.2.3 shall be augmented to include bilateral load at the
M

13  following increments of the maximum displacement, DM :0.25 and 1.0, 0.5 and 1.0, 0.67 and
D ut O

14  1.0, and 1.0 and 1.0.


C

15  If reduced-scale specimens are used to quantify bilateral-load-dependent properties, they shall
16  meet the requirements of Section 17.8.2.7; the reduced-scale specimens shall be of the same type
e C
/

17  and material and manufactured with the same processes and quality as full-scale prototypes.
rik LI

18  The force-deflection properties of an isolator unit shall be considered to be dependent on


o
St B

19  bilateral load if the effective stiffness when subjected to bilateral loading is different by more
PU

20  than 15% from the effective stiffness subjected to unilateral loading.
o

21  17.8.2.5 Maximum and Minimum Vertical Load.

22  Isolator units that carry vertical load shall be subjected to one fully reversed cycle of loading at

23  the total maximum displacement, DTM , and at each of the vertical loads corresponding to the
24  maximum and minimum downward vertical loads, as specified in Section 17.2.7.1 on any one
25  isolator of a common type and size. Axial load and displacement values for each test shall be the

39
1  greater of those determined by analysis using the upper bound and lower bound values of
2  isolation system properties, determined in accordance with Section 17.2.8.5.

3  EXCEPTION: In lieu of envelope values for a single test, it shall be acceptable to perform two
tests, one each for the combination of vertical load and horizontal displacement obtained from

ite rm T

analysis using the upper bound and lower bound values of isolation system properties,

C Fo AF

respectively, determined in accordance with Section 17.2.8.5

at

or e R
7  17.8.2.6 Sacrificial Wind-Restraint Systems.

D
8  If a sacrificial wind-restraint system is to be used, its ultimate capacity shall be established by

U er NT
9  test.

10  17.8.2.7 Testing Similar Units.


ot nd E
n
N U M
11  Prototype tests need not be performed if an isolator unit, when compared to another tested unit,
se li
12  complies with all of the following criteria:
M

13  1. The isolator design is not more than 15% larger nor more than 30% smaller than the
D ut O

14  previously tested prototype, in terms of governing device dimensions; and


C

15  2. The design is of the same type and materials; and

16  3. The design has an energy dissipated per cycle, Eloop , that is not less than 85% of the
e C
/

17  previously tested unit; and


rik LI

18  4. The design is fabricated by the same manufacturer using the same or more stringent
o
St B

19  documented manufacturing and quality control procedures; and


PU

20  5. For elastomeric type isolators, the design shall not be subject to a greater shear strain nor
o

21  greater vertical stress than that of the previously tested prototype; and
22  6. For sliding type isolators, the design shall not be subject to a greater vertical stress or
23  sliding velocity than that of the previously tested prototype using the same sliding
24  material.

25  The prototype testing exemption above shall be approved by independent design review, as
26  specified in Section 17.7.

40
1  When the results of tests of similar isolator units are used to establish dynamic properties in
2  accordance with Section 17.8.2.3, in addition to Items 2 to 4 above, the following criteria shall
3  be satisfied:

7. The similar unit shall be tested at a frequency that represents design full-scale loading

ite rm T

rates, in accordance with principles of scaling and similarity.

C Fo AF

8. The length scale of reduced-scale specimens shall not be greater than two.

at

or e R
7  17.8.3 Determination of Force-Deflection Characteristics.

D
8  The force-deflection characteristics of an isolator unit shall be based on the cyclic load tests of

U er NT
9  prototype isolators specified in Section 17.8.2.

10  As required, the effective stiffness of an isolator unit, keff , shall be calculated for each cycle of
ot nd E
n
11  loading as prescribed by Eq.uation (17.8-1):
N U M
se li | F |  | F |
M

keff 
12  | Δ |  | Δ | (17.8-1)
D ut O

where F  and F  are the positive and negative forces, at the maximum positive and minimum
C

13 
14  negative displacements Δ and Δ , respectively.
e C
/

15  As required, the effective damping, β eff , of an isolator unit shall be calculated for each cycle of
rik LI

16  loading by Eq.uation (17.8-2):


o
St B
PU

2 Eloop
β eff 
o

17 
π keff (| Δ  |  | Δ  |) 2 (17.8-2)

18  where the energy dissipated per cycle of loading, Eloop , and the effective stiffness, keff , shall be
19  based on peak test displacements of Δ and Δ .

20  As required, the postyield stiffness, kd , of each isolator unit shall be calculated for each cycle of
21  loading using the following assumptions:

41
k1
1  1. A test loop shall be assumed to have bilinear hysteretic characteristics with values of ,
kd fo f keff
2  , , y, , and Eloop , as shown in Fig.ure 17.8-1.

2. The computed loop shall have the same values of effective stiffness, keff , and energy

ite rm T

C Fo AF
4  dissipated per cycle of loading, Eloop , as the test loop.

at
5  3. The assumed value of k1 shall be a visual fit to the elastic stiffness of the isolator unit

or e R
6  during unloading, immediately after DM .

D
U er NT
ot nd E
n
N U M
se li
M
D ut O C

8  FIGURE 17.8-1. Nominal properties of the isolator bilinear force-deflection model.


e C
/
rik LI

9  It is permitted to use different methods for fitting the loop, such as a straight-line fit of kd
o
St B

10  directly to the hysteresis curve extending to DM and then determining k1 to match Eloop .
PU

11  17.8.4 Test Specimen Adequacy.

12  The performance of the test specimens shall be deemed adequate if all of the following
13  conditions are satisfied:

14  1. The force-deflection plots for all tests specified in Section 17.8.2 have a positive
15  incremental force-resisting capacity.

42
1  2. The average postyield stiffness, kd , and energy dissipated per cycle, Eloop , for the three
2  cycles of test specified in Section 17.8.2.2, Item 3, for the vertical load equal to the
3  average dead load plus one-half the effects caused by live load, including the effects of
heating and rate of loading, in accordance with Section 17.2.8.3, shall fall within the

ite rm T

5  range of the nominal design values defined by the permissible individual isolator range,

C Fo AF
which are typically  / –5% greater than the λ(spec,min) and λ(spec,max) range for the average

at

or e R
7  of all isolators.
0.67DM and 1.0DM specified in Item 2 and

D
8  3. For each increment of test displacements

9  Item 3 of Section 17.8.2.2, and for each vertical load case specified in Section 17.8.2.2,

U er NT
10  the value of the postyield stiffness, kd , at each of the cycles of test at a common
11  displacement shall fall within the range defined by λ(test,min) and λ(test,max) multiplied by
ot nd E
n
12  the nominal value of postyield stiffness.
N U M

13 
se li
4. For each specimen, there is no greater than a 20% change in the initial effective stiffness
M

14  over the cycles of test specified in Item 4 of Section 17.8.2.2.


D ut O

15  5. For each test specimen, the value of the postyield stiffness, kd , and energy dissipated per
C

16  cycle, Eloop , for any cycle of test in Section 17.8.2.2, Item 4(a) shall fall within the range

of the nominal design values, defined by λ(test,min) and λ(test,max) .


e C

17 
/

18  6. For each specimen, there is no greater than a 20% decrease in the initial effective
rik LI

19  damping over the cycles of test specified in Item 4 of Section 17.8.2.2.
o
St B

20  7. All specimens of vertical load-carrying elements of the isolation system remain stable
PU

21  where tested, in accordance with Section 17.8.2.5.


o

22 
23  EXCEPTION: The registered design professional is permitted to adjust the limits of Items 3, 4,
24  and 6 to account for the property variation factors of Section 17.2.8.4 used for design of the
25  isolation system.

26  17.8.5 Production Tests.

43
1  A test program for the isolator units used in the construction shall be established by the
2  registered design professional. The test program shall evaluate the consistency of measured
3  values of nominal isolator unit properties by testing 100% of the isolators in combined

4  compression and shear, at not less than two-thirds of the maximum displacement, DM ,

ite rm T
5  determined using lower bound properties.

C Fo AF
at
6  The mean results of all tests shall fall within the range of values defined by the λ(spec,max) and

or e R
7  λ(spec,min) values established in Section 17.2.8.4. A different range of values is permitted to be

D
8  used for individual isolator units and for the average value across all isolators of a given unit
type, provided that differences in the ranges of values are accounted for in the design of each

U er NT

10  element of the isolation system, as prescribed in Section 17.2.8.4.
ot nd E
17.9 CONSENSUS STANDARDS AND OTHER REFERENCED DOCUMENTS

n
11 
N U M

12 
se li
See Chapter 23 for the list of consensus standards and other documents that shall be considered
M

13  part of this standard to the extent referenced in this chapter.


D ut O C
e C
/
rik LI
o
St B
PU

44