EXAMPLE 9

Let's design this connection as slip-critical:


Group B-N 3/4 in dia bolts are used
A572 Gr.50 steel is used
Service load
D 65 kip
L 115 kip

SOLUTION

A572 Gr.50 Fu 65 ksi AISC Tab 2-4, P 2-48

Factored load D 65 kip


L 115 kip
PU 262 kip

Bolt shear AISC Tab 7-1, P 7-22


db 0.75
Group B-N
single shear

ϕrn 22.5 kip/bolts

Bolt slip AISC Tab 7-1, P 7-22


Group B
db 0.75
single slip

ϕrn 11.9 kip/bolts

ϕrn 11.9 kip/bolts

Number of bolts Nb = P u /ϕ r n = 22.02

use 24 bolts