Accurate Tool Company

in Kilgore Texas has been


manufacturing
insertable corrosion
coupon holders,
injection atomizers, and
sample probes for 25
years. Their unique
designs incorporate
patented features for
safe and easy use in high
pressure applications.
MODEL MM-15HT 1500 psi MAOP
Warning Indicator
(Rod/Probe Lock Bolt is not tight)

Rod Adapter

Rod/Probe

Safety Cap

Lock Bolt (5/8”)


Collet Assembly

Graphoil Packing
Gland

Packing Gland Lock Bolt

Pressure Bleeder Valve


(for removal)

Welded Safety Stop

Insulated Coupon Holder: Specify Type of Coupon*


Flat style coupons should be positioned narrow side towards flow.
Red Safety Cap Indicator
MODEL FMM-50 *5000 psi MAOP Probes & HT
* 7500 psi MAOP Rods (*Rated to flange)
Rod Adaptor*
Allows the rod or probe to be bolted to the draw bar on the special tool so the rod or probe
can be pulled from the process (mandatory when the rod or probe is bent).
Specify if Special HP EXL Tool will be used*

Rod or Probe
Indicate length and diameter (1/4” or 3/8” when ordering)

Safety Cap
Indicate EXL (15” Long) when ordering.
* Standard Cap is 10” long.
Locking Bolt
Indicate MM50 Holder
Locking Collet
Indicate MM50 and Rod Diameter
Teflon Seal (Specify Rod Diameter)

Seal Body Lock


Allen Screw

Pressure Bleeder Valve


Indicate MM50

Welded Safety Stop

Insulated Coupon Holder


Indicate style when ordering a rod.
Warning Indicator
Up position indicates that the locking device requires
tightening prior to the removal of the safety cap.
MODEL FMM-50HT
Rod Adapter (Specify if EXL)

Safety Cap
Prevents the coupon holder from complete retraction should the locking
device loosen due to pipeline vibration. It also protects the insertion tool
mounting threads.
Insertion Tool Mounting Threads

Locking Device (patented)


Holds the coupon at the desired monitoring zone within the
pipeline. Design will hold with 7500 psi against it without
marring the rod.

Packing Gland Body


Packing Gland Locking Bolt
Allows for tightening the packing gland (HT Version).

Bleeder Valve
To bleed the pressure off the body once the
isolation valve has been closed.

Flanged Body (1/2” – 2” NPT Available)


Mounting connection for the isolation valve on the pipeline.
Rod * (1/4” – 1/2” OD Available)
EXL = Extended length above 48”
Welded safety stop

Insulated Coupon Holder


All styles available (for flat coupon shown)
The Special HP tool
is used to insert and
retract
coupon holder rods
and injection probes
when the
Insertion lengths are
less than
48”. 7500 psi MAOP
Rod Guide
Threaded for rod guide
Tube. Special HP EXL Tool
For Extended Length (+48”)
Rods and Probe shafts
Grease Fitting
7500 psi MAOP
Gear Rod
Moves the draw bar.

Draw Bar Locking Collet (patented)


Locks to the rod or probe to move it 48” per stroke insertion or retraction.
* Collet must be oriented correctly and dot indicates top.

Draw Bar

Swivel Mounting Nut


Mounts to the threads on the holder.

Hand Crank
Inserts and controls the speed of retraction.

Grease Fittings
MOUNTING CONFIGURATIONS FOR THE ACCURATE TOOL COMPANY’S (ATCO) INSERTABLE CORROSION COUPON HOLDERS, INJECTION
ATOMIZERS, AND SAMPLER / QUILLS.

Add “H” to “A” dimension for coupon holders.

Not Applicable Add “H” to “A” dimension for


coupon holders.

TO DETERMINE TOTAL ROD OR PROBE LENGTH:

CORROSION COUPON HOLDERS: ADD 12” (MODELS MM15HT & MM50) to (“A” + “H’) DIMENSIONS (DO NOT SUBTRACT COUPON LENGTH)

ADD 8” (MODELS LP200HT, LP750HT, & M-1) to (“A” + “H”) DIMENSIONS (DO NOT SUBTRACT COUPON LENGTH)

ATOMIZERS, SAMPLERS / QUILLS: ADD 14” (MODELS MM-15HT & MM50) to “A” DIMENSION.

ADD 10” (MODELS LP200HT & LP750HT) to “A” DIMENSION.


INSTALLATION INSTRUCTIONS FOR THE MODEL MM-15 &
MODEL MM-50 COUPON HOLDERS AND INJECTION PROBES

1) Loosen the 5/8” rod / probe locking bolt and push the rod / probe through the end of
the holder and attach coupon or atomizer nozzle.
2) Retract the probe or rod to just inside the bottom of the holder and tighten the 5/8” lock
bolt.
3) Measure from the top face of the pipeline isolation valve (a full bore ball or gate valve)
to the desired zone within the pipeline.
4) Transfer this measurement to the exposed rod / probe and mark with a permanent
marker. For flat coupon holders, mark the rod adapter with the direction of flow against
the narrow side of the coupon (Figure 2).
5) Attach the MM-15 or MM-50 to the process isolation valve (Figure 1).
SHORTCUT (coupon holders only): Insert the coupon holder to the bottom of the pipe. Lightly touch
the coupon on the bottom then retract it approximately 1/4” (3/4 turn on the hand crank counter
clockwise) and make a permanent mark on the rod at the top base of the holder (Figure 2).
6) Models MM-15HT and MM-50HT (with packing glands):
a) Once the unit is firmly affixed to the isolation valve, and the bleeder valve
is closed, slowly open the isolation valve to apply process pressure to the unit.
b) *The graphoil packing will require tightening to stop leaks. Loosen the packing
assembly lock bolt (1/4”-20) and turn the body slowly clock wise until no leak is
present.
7) Close isolation valve and attach insertion tool!
*CAUTION: Over tightening the graphoil packing puts friction on the rod / probe
requiring more force to insert and prevents a smooth travel during retraction.
Figure 1
Figure 2
INSTALLATION AND USE OF THE SPECIAL HP TOOL FOR INSERTION
OF THE MODEL MM-15 AND MODEL MM-50
1) With the process isolation valve closed, turn the hand crank counter
clockwise to move the draw bar to the retracted position of the coupon holder
or atomizer / quill.
2) Position the brass swivel mounting nut on the base of the tool where the slot
is open. (Figure 3)
3) Slide the slot over the rod/probe of the MM-15 / MM-50 and tighten the swivel
nut on the adjacent male threads of the MM-15 / MM-50.
4) Adjust the draw bar position with the hand crank until the rod adapter threads
are exposed through the draw bar.
5) Remove the 5/8” nut from the storage post (Special HP Tool only) on the top
of the tool.
6) Thread the 5/8” nut onto the rod/probe adapter and tighten. (Figure 4)
7) Slowly open the process isolation valve. *Note leaks may be present around
the graphoil packing (if applicable).
8) With a firm grip on the hand crank, loosen the rod / probe locking bolt and
turn the hand crank clockwise to insert to the desired depth (viewing the
permanent mark ,made in the previous step, through the tool base slot).
9) Tighten the rod / probe locking bolt. NOTE: 35 ft lbs of Torque will Hold a 3/8”
Diameter Rod in Place Against 7500 psi Process Pressure.
10) With tool attached, loosen the packing gland lock bolt and turn the packing
gland assembly clock wise until no leak is present. Tighten the packing gland
assembly lock bolt.
11) Remove the tool and attach safety cap or safety chain. (Figure 5)
Figure 3
Figure 4
Figure 5
INSTALLATION AND USE OF THE SPECIAL HP TOOL FOR RETRACTION
OF THE MODEL MM-15 AND MODEL MM-50

1) Remove the safety cap or safety chain.


2) Turn the hand crank clockwise to move the draw bar to the
inserted position of the coupon holder or atomizer / quill.
3) Position the brass swivel mounting nut on the base of the tool
where the slot is open.
4) Slide the slot over the rod/probe of the MM-15 / MM-50 and
tighten the swivel nut on the adjacent male threads of the MM-15
/ MM-50.
5) Adjust the draw bar position with the hand crank until the rod
adapter threads are exposed through the draw bar.
6) Remove the 5/8” nut from the storage post on top of the tool
(Special HP Tool only).
7) Thread the 5/8” nut onto the rod/probe adapter and tighten.
8) With a firm grip on the hand crank, loosen the rod / probe
locking bolt and turn the hand crank clockwise to insert to the
desired depth (viewing the permanent mark ,made in the
previous step, through the tool base slot).
9) Tighten the rod / probe locking bolt and remove tool. NOTE: 35 ft
lbs of Torque will Hold a 3/8” Diameter Rod in Place Against 7500
psi Process Pressure.
10) Attach safety cap or safety chain.
INSTALLATION AND USE OF THE SPECIAL HP EXL TOOL FOR
INSERTION / RETRACTION OF THE MODEL MM-15 AND MODEL MM-50

1) Turn the hand crank counter clockwise to move the draw bar to the fully retracted
position of the rod / probe (measurement required).
2) Remove the locking collet assembly from the draw bar. CAUTION: Collet must be
reinstalled with the correct side up. The top is marked with a dot.
3) Position the brass swivel mounting nut on the base of the tool where the slot is
open.
4) Slide the slots of the mounting swivel nut, draw bar, and top bar (top bar may
have an optional support tube) over the rod / probe of the MM-15 / MM-50 and
tighten the swivel nut on the adjacent male threads of the MM-15 / MM-50.
5) Attach the locking collet assembly to the draw bar and tighten (for multiple draw
bar travels on extended length rods/probes merely loosen the lock bolt each
pass).
• With the locking collet 5/8” bolt tight* against the rod/probe, and the locking bolt
tight* on the MM-15/MM-50, slowly open the process isolation valve. * NOTE: 35
ft lbs of Torque will Hold a 3/8” Diameter Rod in Place Against 7500 psi Process
Pressure.
7) With a hand on the tool crank handle, loosen the rod / probe locking 5/8”
bolt and turn the hand crank clockwise to insert to the desired depth (permanent
mark made in the previous step).
8) For the final insertion stroke, tighten the draw bar locking collet onto the 3/8”rod
adapter.
9) Tighten the rod / probe locking bolt and remove tool.
10) Attach safety cap or safety chain.
REPEAT # 5-8 FOR ROD/PROBE LENGTHS OVER 48”
Rod Guide
Threaded for rod guide
Tube. Special HP EXL Tool
For Extended Length (+48”)
Rods and Probe shafts
Grease Fitting
7500 psi MAOP
Gear Rod
Moves the draw bar.

Draw Bar Locking Collet (patented)


Locks to the rod or probe to move it 48” per stroke insertion or retraction.
•Collet must be oriented correctly and dot indicates top.
CAUTION: Never Loosen this Locking Collet Unless You are Certain the Holder
Locking Collet is Tight.

Draw Bar

Swivel Mounting Nut


Mounts to the threads on the holder.

Hand Crank
Inserts and controls the speed of retraction.

Grease Fittings
Special EXL HP Tool Rod Extension Guide
Inserts and Retracts Rods and (3 foot Sections)
Probes up to 48” and Above.
(22 Foot Maximum)
The Same Instructions Apply to Injection Atomizers and Quills
Holders can be mounted in any position!