Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 4

Thrust Load (lbf) per stage @ 60 Hz Operation Fq, Hz

Pump Type BEP Shut Off Q required, BFPD


Compression Floater Compression Floater # Stages
WD1000MF 10.7 4.7 16.5 6.6 Head@Q required
Head@0 flow
Head coefficient
SG
Thrust at shut in, lbf
Hoperational, ft
Hshut in, ft
Operating Thrust, lbf

Thrust Load (lbf) per stage @ 60 Hz


Pump Type BEP Shut Off
Compression Floater Compression Floater
WD1000MF 10.7 4.7 16.5 6.6
WE2600 96.3
WE1500 44.3
WE11000 71
WE8500 39.1
WH15000 71
WH20000 101
WH30000 88.72
56.13
1300
246 INPUT
26 DATA
39
0.9
1
16.5
5756.4 * Go to pump curve by using Q rate and # stages
9594 * Go to pump curve by using 0 BFPD and # stages
2131
P* 3000
PWF 1500 NVL 5536
Q 10000 TDH 5636
THP 100 Lev Etapa 41
IP 6.67 #etapas 137
Bomba etapas 139
PIP en pies 924
Pot etapa 4.25
Potencia Bomba 591
Motor tandem 313 2027
313 2027
626 4054

Fq2 55 Q required, BFPD 10000


Q2 9167 # Stages 139
TDH2 4736 Thrust at shut in, lbf 71
HP2 455 Operation Fq, Hz 55
SG 1
Hoperational, ft 5699
Hshut in, ft 6811
Operating Thrust, lbf 6939
Asentamiento 6460
Perdida cable #2 35.1
Perdida total 227
Volt SUT @ 60 Hz 4281

92.6
92.6
92.6

Carga Ejes
Bomba Monel 625 79%
HSS 1000 50%
UHSS 1250 40%

Carga Motor 0.73


FP 0.78
Carga electrica 0.77
Corriente oper 55Hz 71.302

You might also like