POWER SURVEY FORM


TOWER INDEX : SUM-SB-PMN-0357
SITE ID/ SITE NAME : C338 TOBOH PALAPAH
Site Category : HUB
DATE OF CHECK : 6/21/2021 format : dd/mm/yyyy
PURPOSES : Check Power
INDOOR SHELTER : INDOOR+MIX OUTDOOR 1Shelter / 2Shelter/ 3Shelter/ 4Shelter/ 5Shelter
PIC/No Hp : ZIKRI ADE PUTRA

PLN+GENSET RECTIFIER SYSTEM


Shelter Type of Current Cap No of Module Current Load No of Battery cap Recty Status Battery Est Battery
AC Power System & Genset Actual status Rectifier Brand Module Module (A) (pcs) (Adc) Battery Brand Battery Type Bank (Ah) Battery Remark Utility (%) Recifier Perform Backup Time Connect to

Phase 1 Shelter1 EATON POWERWARE APR48 3G 51 3 51 WOLONG WL48-50FT11 8 100 Backup 120 minute 59.5 Sufficient 70% 8.78 , IPASO, ATN CSR
PLN MCB Capacity (Each Phase) 35
PLN Installed (VA) 23,037 OUTDOOR HUAWEI NETECO R4850G 32 3 32 SHOTO 6-FMX-100B 1 100 60 38.5 Sufficient 0.00 BTS
Genset Apparent Power Installed (VA) 0
Genset Real Power Installed (W) 0.0 Shelter3 Input Battery Perform as percentage from the result of
measurement by Battery Tester
Current Load - R (A) 34.00 (Hioki/Aitelong/Midtronic)
Current Load - S (A) 0.00
Current Load - T (A) 0.00 Shelter4
PLN Used (VA) 22,379
PLN Usage without battery Charging (%) 97.1 Remark : Conclusion :
Battery charging (VA) 2,739 1. PLN usage still < 90%. It's safe 1. Proposed add module rectifier
PLN Used With battery charging (VA) 25,118 2. Need add bank battery and add rectifier module 2. Proposed add bank battery
PLN Usage With Battery Charging (%) 109.0 3. Need add permanent genset 3. Proposed add perment genset
Genset Used after add New Load (VA) 25,118
Genset Usage after add New Load (%) #DIV/0!
Running Hour Genset (h) -

ACPDB Shelter#1 Diisi SHELTER SIZE Diisi Requirement aircond N+1


Phase R in ACPDB (Ampere) 5.33 Length 0 1.5pk 0 0
Phase S in ACPDB (Ampere) 5.18 Width 0 or 2pk 0 0
Phase T in ACPDB (Ampere) 5.08 Height 0 or 4pk 0 0
MCB (Ampere) 63 or 5pk 0 0
MCB (VA) 41466.6
Utility MCB (%) 8.5
AIR CONDITIONER Diisi Btu watt Sensible/unit
Room Size (watt) 0.00 0 x 1.5pk 12000 3400 7800
Rectifier (watt) 0.00 0 x 2pk 18000 5200 11700
Load equipment (watt) 0.00 0 x 4pk 36000 10400 23400
Total (watt) 0.00 0 x 5pk 45000 13000 29250
Utilization (%) #DIV/0! Total cooling 0 watt
Have DC fan (Yes/No) Yes Sensible cooling cap 0 watt
ACPDB OUTDOOR Diisi SHELTER SIZE Diisi Requirement aircond N+1
Phase R in ACPDB (Ampere) 5.35 Length 0 1.5pk 0 0
Phase S in ACPDB (Ampere) 5.4 Width 0 or 2pk 0 0
Phase T in ACPDB (Ampere) 5.24 Height 0 or 4pk 0 0
MCB (Ampere) 63 or 5pk 0 0
MCB (VA) 41466.6
Utility MCB (%) 8.6
AIR CONDITIONER Diisi
Room Size (watt) 0.00 0 x 1.5pk
Rectifier (watt) 0.00 0 x 2pk
Load equipment (watt) 0.00 0 x 4pk
Total (watt) 0.00 0 x 5pk
Utilization (%) #DIV/0! Total cooling 0 watt
Have DC fan (Yes/No) NO Sensible cooling cap 0 watt
Evidence
Tower ID SUM-SB-PMN-0357
Site ID C338
Site Name TOBOH PALAPAH

PLN capacity 1x35A Voltage 192.50 Vac Rectifier1,2 view Transmisi, MBH, RBS

MCB PLN installed Load R (34.85A)

Rectifier1 , 2 view Load rectifier1, 2 Battery current limit Battery capacity setting
Battery installed viewBattery brand : shoto dan wolong Equipment installed ac broken
courtesy of Mochamad Hamdani

POWER SURVEY FORM


TOWER INDEX : SUM-SB-PMN-0357
SITE ID/ SITE NAME : C338_TOBOH PALAPAH
Site Category : HUB
DATE OF CHECK : 6/21/2021 format : dd/mm/yyyy
PURPOSES : Check Power
INDOOR SHELTER : INDOOR+MIX OUTDOOR 1Shelter / 2Shelter/ 3Shelter/ 4Shelter/ 5Shelter
Input Battery Perform as percentage from the result of
PIC/No Hp : ZIKRI ADE PUTRA measurement by Battery Tester
(Hioki/Aitelong/Midtronic)
PLN+GENSET RECTIFIER SYSTEM
Shelter Type of Current Cap No of Module Current Load No of Battery cap Recty Status Battery Est Battery
AC Power System & Genset Actual status Rectifier Brand Module Module (A) (pcs) (Adc) Battery Brand Battery Type Bank (Ah) Battery Remark Utility (%) Recifier Perform Backup Time Connect to

Phase 3 Shelter1 Huawei TP48200 TP48 50 2 20 Leoch AGM100AH 2 100 Backup 120 minute 30.0 Sufficient 70% 5.60 RBS, IPASO, MBH
PLN MCB Capacity (Each Phase) 10
PLN Installed (VA) 6,582 Shelter2
Genset Apparent Power Installed (VA) 0
Genset Real Power Installed (W) 0.0 Shelter3
Current Load - R (A) 2.27
Current Load - S (A) 2.37 SUM-SB-PMN
Current Load - T (A) 2.35 Shelter4
PLN Used (VA) 1,560
PLN Usage without battery Charging (%) 23.7 Remark : Conclusion :
Battery charging (VA) 609 1. PLN usage still < 90%. It's safe 1. Battery test to make sure battery condition, if only backup under 30 mnt need to replace.
PLN Used With battery charging (VA) 2,169
PLN Usage With Battery Charging (%) 32.9
Genset Used after add New Load (VA) 2,169
Genset Usage after add New Load (%) #DIV/0!
Running Hour Genset (h) -

ACPDB Shelter#1 Diisi SHELTER SIZE Diisi Requirement aircond N+1


Phase R in ACPDB (Ampere) 2.27 Length 0 1.5pk 2 3
Phase S in ACPDB (Ampere) 2.37 Width 0 or 2pk 2 3
Phase T in ACPDB (Ampere) 2.35 Height 0 or 4pk 2 3
MCB (Ampere) 10 or 5pk 2 3
MCB (VA) 6582
Utility MCB (%) 23.7
AIR CONDITIONER Diisi Btu watt Sensible/unit
Room Size (watt) 0.00 0 x 1.5pk 12000 3400 7800
Rectifier (watt) 86.40 0 x 2pk 18000 5200 11700
Load equipment (watt) 756.00 0 x 4pk 36000 10400 23400
Total (watt) 842.40 0 x 5pk 45000 13000 29250
Utilization (%) #DIV/0! Total cooling 0 watt
Have DC fan (Yes/No) Yes Sensible cooling cap 0 watt
ACPDB Shelter#2 Diisi SHELTER SIZE Diisi Requirement aircond N+1
Phase R in ACPDB (Ampere) 0 Length 0 1.5pk 1 2
Phase S in ACPDB (Ampere) 0 Width 0 or 2pk 1 2
Phase T in ACPDB (Ampere) 0 Height 0 or 4pk 1 2
MCB (Ampere) 0 or 5pk 1 2
MCB (VA) 0
Utility MCB (%) #DIV/0!
AIR CONDITIONER Diisi
Room Size (watt) 0.00 0 x 1.5pk
Rectifier (watt) 0.00 0 x 2pk
Load equipment (watt) 0.00 0 x 4pk
Total (watt) 0.00 0 x 5pk
Utilization (%) #DIV/0! Total cooling 0 watt
Have DC fan (Yes/No) NO Sensible cooling cap 0 watt