Professional Documents
Culture Documents
Brosur Perancah
Brosur Perancah
Brosur Perancah
U S E R G U I D E F O R G E N U I N E K W I K S T AG E
contents
Section 1
Kwikstagecomponents 5
Section 2
Erectionanddismantlingofa 11
basicKwikstagescaffold
Section 3
Safeuseandmaintenance 17
Section 4
Loadingdataandtiepatterns 18
Section 5
Bracingrequirements 52
Section 6
Platformbrackets 53
Section 7
Ladderandstairaccess 54
Section 8
Loadingtower 57
Section 9
Kwikstagesafeanchoragepoints 59
Appendix A -Identificationand 61
useofalternativecomponents
Thisguideisvalidonlyfortheuseof
GenuineKwikstagemanufactured,repaired
andmaintainedwhereappropriatebyInterserve
IndustrialorRMDKwikform.
FirstIssue2010
1 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
userguide
TheDesignationofaGenuineKwikstageScaffoldinaccordancewith
BSEN12810-1:2003is:Scaffold EN 12810-4N-SW12/244-H1-B-LS
The“Kwikstageforaccess”User DISCLAIMER:
Guidehasbeendesignedtoprovide InformationgiveninthisUserGuide
guidanceonhowtosafelyerect, relatessolelytoequipment
useanddismantlebasic manufacturedandsuppliedbyRMD
IndependentAccessScaffolds KwikformandInterserveIndustrial.
formedfromKwikstage. AnumberofKwikstageimitations
areavailable,thequalityofwhich
Requirementscontainedincurrent isunknown.Wherescaffold
CENandBSStandardshavebeen structuresareerectedwholly,orin
implementedtogetherwiththoseit part,fromsuchcopyequipment,
isanticipatedwillbecontainedin instructionsforitsuseshouldbe
Standardscurrentlyunder obtainedfromthemanufacturerof
preparation. thecopyequipment.
Aspartoftheongoingdevelopment
ofKwikstage,andtofacilitate NOTE:
compliancewithchangesin Only trained, competent
legislation,anumberofnew operatives should erect, dismantle
componentshavebeenintroduced, or adapt Kwikstage scaffolds at
somecomponentshavebeen all times.
discontinuedandthedesignand/or
useofothersmodified. Safe systems of work for the
erection, dismantling or
ThisUserGuideisdesignedforsafe adaptation of Kwikstage scaffolds
useofKwikstagecomponentsas should reflect current legislative
currentlymanufactured.Wherethe and industry best practice
designoruseofacomponenthas methodology.
changedsignificantly,information
onthecomponentconcernedis We recommend that as a minimum
giveninAppendixA. the guidelines for working
practices for scaffolders working
Guidanceisprovidedforscaffolds at heights contained in document
ofbothnominal1.2m(5board)and SG4, produced by the National
0.8m(3board)widths. Access and Scaffolding
Confederation (NASC) are applied
For information on Kwikstage to activities taking into
components and applications not consideration the requirements
shown in this User Guide, please for advanced guardrails.
consult your local Branch.
FirstIssue2010
G E N U I N E K W I K S T A G E 2
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
guidetosafe
scaffolding1
Always Ensureallon-siteusersknowforwhatpurposethe
scaffoldisintendedandtheloadsitisdesignedto
take.
Always Preparethegroundforthescaffoldandtheloadsit
willimpose.
Always Ensurethatyouprovideagreedstorageareasfor
scaffoldingonsitetoreducehandlingandprevent
trippinghazards.
Always Keepaccessroutesclear.
Always Inspectthescaffoldeachtimebeforeuse.
Always Inspectyourscaffoldsandissuereports.Itis
requiredbylaw.
Always Giveconsiderationtotheuseofataggingsystem.
Always Preventaccesstoincompleteand/orunsafe
scaffoldsandensurethatyouhave“scaffoldnotto
beused”signsinplace.
Always Tellthescaffoldingcontractorifthescaffoldgets
damaged,repairscanthenbearranged.
Always Protectscaffoldfromdamagebysiteplant.
Always Ensureloadsontheplatformareevenlydistributed.
Always Considertheweightofthematerialsyouare
loadingonthescaffoldandinstructoperativeson
maximumloading.
Always Instructforkliftdriveronmaximumloading.
Always Useproperlydesignedloadingtowers.
Always Instructtheoperativeswhowillbeusingthe
scaffoldnottomakeanyadaptations.
Always Reportscaffolddefectstoscaffoldingcontractor-
youmaybesavingalife.
ALWAYS LOOK AFTER YOUR
SCAFFOLDING. BE SAFE.
FirstIssue2010
3 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
guidetosafe
scaffolding2
Never *RemoveTies.
Never *Removeguardrails,toeboards,orbrickguards.
Never Removecomponentsoradaptscaffolding.
Never Creategapsinplatformbyremovingscaffoldboards
fromplatform.
Never Workonorusescaffoldswhicharebeingerectedor
dismantled.
Never Removeladders.
Never Overloadthescaffold.
Never Underminethescaffoldbydiggingtrenchesor
foundationsunderoradjacenttoit.
Never Addsheetingornettingtoscaffoldwithoutthe
approvalofthescaffolddesigner.
Never Forkliftloadsdirectlyontoaccessscaffold
(instead,usealoadingtower).
Never Allowsiteplanttorunoverscaffoldmaterials,
damagedscaffoldboardscauseaccidents.
Never Allowsiteplanttorunintoscaffold,benttubes
couldleadtocollapseofthestructure.
*Exceptwhenusingtrainedcompetentoperatives,workingto
youragreedsiterequirementsandinstructions.
NEVER
TAKE
RISKS –
THEODDSARE
AGAINSTYOU
FirstIssue2010
G E N U I N E K W I K S T A G E 4
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
section1components
ThefollowinglistdetailsbasicKwikstagecomponents.Additionalcomponentstocaterfor
specificapplicationsareavailablefromyourlocalRMDKwikformorInterserveIndustrialbranch.
Allcomponentdimensionsarenominal.Weightsofcomponentsrelatetothosecurrentlyin
productionandmaydifferfromearlierdesigns.
UniversalJack Ledger/Guardrails
Designedforlevellingascaffold Thesecomponentshaveawedgefixingdevice
wheregroundorfoundationlevels ateachend.Thesefitintotheupper‘V’
vary.Adjustmentisbymeansofa pressingsontheStandardstolocatethemat
collaronathreadedstem. therequiredlongitudinalspacing.Theyareused
inpairsasLedgersateach‘lift’,andto
Universal Jack formGuardrailsatplatformlevel.
CodeNo.(RMDK) KAX20005
CodeNo.(Interserve) 9001
Weight 6.5kg
Range:closeddimension 140mm
Maximumadjustment 595mm
3m Standard
CodeNo. KAX32000
CodeNo. 9015
Weight 12.0kg
FirstIssue2010
5 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
ReturnTransoms TieBars
Thesecomponentsaresimilartonormal TieBarsareformedfromsteelangle,with
Transomsexceptthattheyhaveapressedsteel curvedlugsateachendwhichengageinholes
sectionthathooksoveraLedgertoforma90
o
in2and3BoardPlatformBrackets.TieBarsmust
returninascaffold. alwaysbeusedtopreventthespreadingof 2and
3BoardPlatformBrackets.
DiagonalBraces
Thesecomponentsareformedfromtube,with
PlatformBrackets pivotingwedgedevicesateachend.Thesefit
intotheoutside‘V’pressingsontheStandards.
PlatformBracketsareusedtoprovidea
cantileveredplatformontheinnersideofa
scaffold.Theyareformedfromaninverted
T-sectionwithawedgefixingdeviceatone
endwhichfitsintoa‘V’pressingonaStandard. 2.76m Diagonal Brace 3.54m Diagonal Brace
TieBarsmustalwaysbeusedwith2and3
CodeNo. KAX62744 CodeNo. KAX63658
BoardPlatformBrackets.
CodeNo. 9051 CodeNo. 9026
Weight 11.0kg Weight 13.9kg
Forusein1.8mBays Forusein2.4mBays
Steelstage
Steelstageisagalvanisedpressedsteelbatten
withaslipresistantsurface.Thesebattensare
230mmwideand64mmdeepandarethe
1 Board Bracket 2 Board Bracket
preferredtypeforformingtheworking
CodeNo. KAX10003 CodeNo. KAX10004 platformsonKwikstagescaffolds.
CodeNo. 9041 CodeNo. 9019
WidthofPlatform 230mm WidthofPlatform 460mm
Weight 2.3kg Weight 4.9kg 1.2m Steel Stage 1.8m Steel Stage
CodeNo. SGX11219 CodeNo. SGX11829
3 Board Bracket CodeNo. 9515 CodeNo. 9513
CodeNo. KAX10005 Standardspacing 1.27m Standardspacing 1.8m
CodeNo. 9022 Weight 8.5kg Weight 12.3kg
WidthofPlatform 690mm 2.4m Steel Stage
Weight 6.5kg CodeNo. SGX12438
CodeNo. 9514
Standardspacing 2.44m
Weight 16.1kg FirstIssue2010
G E N U I N E K W I K S T A G E 6
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
1components
ToeboardBracket StairwayUnit
ThiscomponentclampsontoaStandardby TheStairwayUnitismadefromaluminiumand
meansofacaptivewedge.Itholdseitherone fitsintoa2.4mx2.0mKwikstagescaffold.Itis
ortwoSteelstage connectedtotheTransomsbymeans
toeboardsinposition. ofaboltedclip(ItemNo.7400).
Theoverallwidthoftheunit
Toeboard Bracket is576mm,enablingtwotobe
CodeNo. KAX10009 fixedinastandard1.27m
widebay.
CodeNo. 9029
Weight 0.8kg Stairway Unit
CodeNo. KAX10023
EndToeboardBracket CodeNo. 9042
Thesecomponentsfitinto‘V’ Weight 31.9kg
pressingsonStandardsattheendof
aplatformandholdtheend
Steelstagetoeboardinposition.
HandrailUnit
End Toeboard Bracket Thisaluminiumcomponentfits
CodeNo. KAX10002 intosocketsintheStairwayUnit
toprovideadoubleguardrail.
CodeNo. 9099
Weight 1.3kg Handrail Unit
CodeNo. KAX10016
Kwikguards CodeNo. 9043
Thesegalvanisedsteel Weight 10.0kg
componentsarecombined
Guardrail,Toeboardand
Brickguardunitsandfit
intothe‘V’pressingson
theStandards.
InternalCornerFiller
1.2m Kwikguard 1.8m Kwikguard
Kwikstageinternalcornerfillerhasbeen
CodeNo. KAX10018 CodeNo. KAX10019 designedforusewithtwoandthree
CodeNo. 9068 CodeNo. 9067 boardstagebracketsatinternalcorners
ofbuildings.
Weight 15.0kg Weight 20.0kg
2.4m Kwikguard Internal Corner Filler
CodeNo. KAX10020 CodeNo. KAX10017
CodeNo. 9066 CodeNo. 9053
Weight 25.0kg Weight 8.9kg
LadderAccessTransom
Thiscomponentisusedinaladder
accesstowertoforman
openinginthe
platform.
7 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
LoadingTowerTransom Guardrail/GateRestraint
ThisTransomisdesignedtoconnecttothe Thiscomponentisformedfromgalvanisedsteel
frontpairofStandardsinaloadingtowerby tubeandisfixedtotheKwikguardoneachside
meansofwedgefixingdevices.Thesefitinto ofaloadingtowerbymeansofahalf-coupler
twopairsofupper‘V’pressingsonthe hinge.Inthe‘open’positionitformsabarrier
Standards.ThetopchordoftheTransomisin betweenthemainscaffoldplatformandthe
theformofaninvertedT-section,theflanges towerdeck.Inthe‘closed’positionitformsa
ofwhichformaseatingfortheSteelstage guardrailatthefrontofthetower
decking. andanattachmentpoint
forthegatelatch.
InfillTransom LoadingTowerGates
Thisgateoperatesonafulcrummechanism
Thesegalvanisedcomponentsareusedatthe
attachedtothesidebarrierandsimplyopens
rearofaloadingtowertosupportthe
withanoperatingtubeconnectedbetweenthe
Steelstagedeckingandtofillthegapbetween
arms.Thegatefailssafelytoaclosedposition
itandthemainscaffoldplatform.They
iftheoperatorreleasesholdoftheoperating
connect,bymeansofawedgefixingdevice,to
tube
theStandardsina2.4mscaffoldbayandtoan
additionalstandardatthe
centreofthebay.
FirstIssue2010
G E N U I N E K W I K S T A G E 8
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
1components
AdditionalKwikstage DrilledTransoms
Components SimilartonormalTransomsexceptthatholes
havebeendrilledintheflangetoacceptaTie
Thefollowingtwopagesprovidedetailsof Bar.
additionalcomponentswhichcanbeusedwith
Kwikstagescaffolds. Safe Working Load
MaximumloadonaSteelstageplatform
supportedbyaDrilledTransomisthesameasa
Adescriptionoftheuseandoperationofeach normalTransom.
itemisprovidedtogetherwithaSafeWorking
Loadwhereapplicable.
0.8 Drilled Trandom 1.2 Drilled Trandom
CodeNo. KAX50002 CodeNo. KAX50001
SlidingStageBrackets CodeNo. 9537 CodeNo. 9037
Usedtocreateanaccesswithinrecessesand
Weight 4.6kg Weight 6.8kg
rebateswherefullbaylengthscannotbe
accommodated.Mustbeusedinconjunction
with2&3BoardPlatformBrackets. Always
seek engineering advice prior to use.
3BoardAccessBracket
Usedtocreateanaccessontheoutsideofthe
scaffold,especiallywhereoverhangingeves Safe Working Load
preventaccessalongthemainscaffold.Always
seek engineering advice prior to use. Note:
A0.8mSteelstage(ItemNo.SPU10011orCode
No.9536)maybeusedwiththeTieBartoform
Safe Working Load veryshortcantileverplatformsandbays(using
Engineeringadviceisrequiredat the0.8mTransom-ItemNo.KAX50812orCode
alltimes.MaximumloadonaSteelstage No.9529).
platformsupportedbya3Board
AccessBracketis0.75kN/m2.
0.8m Tie Bar
CodeNo. KAX10001
CodeNo. KAX10026
CodeNo. 9054
CodeNo. 9069
Weight 16.8kg
Weight 2.3kg
FirstIssue2010
9 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
CouplerBrace 16ft(4.877m)
CouplerBraceisusedinallKwikstage
baysthatarecantileveredabovethe
BridgingLedger
lasttie. Providesa4.877mopeningthroughthemain
runofKwikstagescaffold(abridge).Allother
workingplatformsabovethebridgemustbe
producedbysimilarpairsofBridgingLedgers.
Coupler Brace
CodeNo. KAX10013
CodeNo. 9402
Weight 9.0kg
SideLoadingTower
16ft Bridging Ledger
TheInfillTransomisinstalledbetweenthe
platformoftheaccessscaffoldandtheside CodeNo. KAX40001
accessloadingtowerplatform. CodeNo. 9044
Weight 28.5kg
Safe Working Load
TheInfillTransomwillsupportasimilarloadto
theloadingtowerplatform. GuardrailPost
8ft Infill Transom Side Loading Tower AGuardrailPostisrequiredtobefitted
atmidspanoftheBridgingLedger.No
CodeNo. 9030
otherKwikstagecomponentshouldbe
Weight 19.4kg fittedatmidspan.
Guardrail Post
CodeNo. KPX10003
CodeNo. 9039
Weight 4.3kg
FirstIssue2010
G E N U I N E K W I K S T A G E 10
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
section2
guidefortheerectionand
dismantlingofabasic
kwikstagescaffold
Kwikstageerectedinthefollowingmannerandtotheliftheightsandmaximumheightsstatedin
Section4willhaveamaximumloadcapabilityoftheStandardof24.9kN
Onlytrained,competentoperativesshoulderect,dismantleoradaptKwikstagescaffoldsatall
times.Safesystemsofworkfortheerection,dismantlingoradaptationofKwikstagescaffolds
shouldreflectcurrentlegislativeandindustrybestpracticemethodology.
Werecommendthatasaminimumtheprinciplesforworkingpracticesforscaffoldersworkingat
heightscontainedindocumentSG4,producedbytheNationalAccessandScaffoldingConfederation
(NASC)areappliedtoallscaffoldingactivities.Advanced guardrails should be installed in the
approved methods chosen by the erector.
Part1-Straightrun 4Withonepersonholdingtwo
Standardsvertically,anotherfits
scaffolds aTransomoftherequired
lengthintothebottomsetof
Scaffolds around square or
‘V’pressings.Thewedgesshould
rectangular buildings
notbedrivenhomeatthisstage.
2 Ensurethatthereisanadequatefoundation
forthescaffold,andprovidesoleplatesof
suitablesizeandstrengthtospreadtheload (ForoldtypeStandardswithwedge
fromtheStandardsontothefoundation. fittingsatthehead,theouterStandards
musthavethewedgesfacingtheoutside
sothattheydonotobstructthetoeboard.)
3 FitbaseJacksintothebottomoftwo
Standards.AdjusttheJackstosuitthe
approximatelevelofthefirstworking
platformrequired.
FirstIssue2010
11 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
5WiththeStandardsheldupright, 8 Ensurethatthistowerisatthe
thesecondpersonfitstwoLedgers requireddistancefromthebuilding
oftheappropriatelengthinto faceandissquareinplan.(Squarenesscan
thelowestsetof‘V’ becheckedbyplacingaSteelstage
pressings.TheStandards onthebottomTransoms.)AdjusttheJacks
cannowleanover,sothat sothatthebottomTransomsandLedgers
theyaresupportedby arealllevel.Drivehomeallwedgeswitha
thefreeendsofthe singlesharpblowfrom
Ledgers. theKwikstageUniversalToolorsimilar.
9 Ifstartingfromanexternalcornerofa
6 StandardsequippedwithbaseJacksarethen building,positionaStandard,equippedwith
fittedtothefreeendsoftheLedgersanda itsJack,alongsidetheinnerpairofLedgers
Transomisfixedbetween inthealreadyerectedtower.Thiswillform
theStandards. theinsideStandardonthescaffoldreturn.
10 Makesurethatthis
Standardisatthe
correctdistancefrom
thebuildingface,
thenadjusttheJack
sothatthehigher‘V’
pressingsonthe
Standardjusttouch
theundersideofthe
Ledgersinthetower.
11WithonepersonholdingthisStandardin
position,thesecondoperatorhooksaReturn
Transomoftherequiredlengthoverthe
7 FixtwofurtherTransomsattherequiredlift bottomLedgerinthetower,andconnectsit
height(amaximumoffour‘V’pressing tothebottom‘V’pressingintheStandard.
clustersabovethebottomTransoms).Two
Ledgersarethenfixedatthesamelevelto
formatower.
FirstIssue2010
G E N U I N E K W I K S T A G E 12
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
2erection&dismantling
12 AsecondStandard(withJack)isthen 16 Usingaladdertogainaccesstothis
connectedtothisReturnTransomto platform,addStandards,Ledgers,Transoms
formtheoutsideStandardonthe andReturnTransomsinthesamemanneras
scaffoldreturn.AnotherReturn previouslydescribed,butwithouttheneed
Transomisthenfixedatthelevelof forlevelling.
theupperLedgerinthetower.
17 FixaDiagonalBraceontheoutsideof
13 FurtherLedgers,StandardsandTransoms theouterStandardsinthebottomlift
canthenbefixedinthesamemannerasfor ofeachofthebaysspecifiedinSection5.
thefirsttowerandallthewedgesdriven This is a two person operation requiring
home. thewedgefixingdevicesateachendofthe
Bracetobepositionedsimultaneouslyover
the‘V’pressingatthebottomofone
Standard,andontheappropriate‘V’
pressingontheadjacentStandard.Oncein
position,thewedgesontheBracecanbe
drivenhome.
14Successivebaysoftheappropriatesizecan
thenbeerectedinthesame
manner,remembering,wherepossible,
toworkcontinuouslyinonedirection.
18Continueerectingthescaffold,fixing
Note: Methodsofforminginfillor
componentsinthesequenceandmanner
non-standardbayscanbefoundin
describedabove.Alwaysworkfromasafe
Section2Part2.
platformandprogressivelyfixtiestothe
building,asdetailedinSection4.
15 Toerectasecondlift,firstplacean
appropriatenumberofbattensorSteelstage
19 Whentheleveloftheworking
inposition,sittingonthehorizontalpartof
platformisreached,deckoutabay
eachpairofupperTransoms.Thiswillform
withSteelstageoftheappropriate
partofthesafeplatformfromwhichto
lengthtosuitthebaysize.(800mm
work.
widescaffoldsneedthreeSteelstage
perbayand1.2mwidescaffoldsneed
fiveSteelstage.)
FirstIssue2010
13 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
20FixKwikguardtoprovideedgeprotection
fromfallsofmenandmaterials.This
componenthaswedgedeviceswhich
connecttothesecond‘V’pressingabove
theplatform,andpinswhichengageinto
thefirst‘V’pressings.This is normally a
two person operation.
21IfKwikguardisnotavailable,edge
protectioncanbeprovidedasfollows:
a) FixLedgerstoformguardrailsinthefirst
andsecond‘V’pressingsaboveplatform
level,ontheoutsideStandards.
b) FixaSteelstagetotheinsideoftheouter
Standardstoformatoeboard.TheToeboard
isfixedbymeansofToeboardBrackets
whichhavewedgeconnectingdevices
thatfitaroundtheStandards.
c) AttheendsofscaffoldrunsuseTransomsto
formtheguardrails.Fix1.2mSteelstage
toeboardstotheoutsideoftheStandardsby
meansofEndToeboardBrackets.
FirstIssue2010
G E N U I N E K W I K S T A G E 14
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
2erection&dismantling
Part2-Infillor Part3-Internalcorners
non-standardbays 1 WhenprovidingaKwikstagescaffoldfor
buildingswhichhaveinternalcorners,itis
1 Whatevertheplandimensionsofabuilding, preferabletostarterectionfromthose
itisnormallypossible,withcareful internalcorners.Thelayoutofthescaffold
planning,toerectaKwikstagescaffold shouldbeplannedaccordingly.
aroundtheperimeterofabuildingwithout
non-standardbays.Iftheyarerequired,any
infillgapsshouldoccurawayfromthe 2 Thetwomostcommonwaysof
corner(i.e.inastraightrun)andbekept accommodatinginternalcornersare:
within600mm.
a) Byusingamirroredversionofthemethodof
2 Leaveanyinfillareasuntilallthestandard formingexternalcornersasdescribedin
Kwikstagebayshave Section2Part1.
beenerected.
b) Byformingasquaretowerinthecornerand
3 ConnecttheKwikstageStandardsoneach thenconnectingbaystothattower.
sideoftheinfillareatogether,ateach
Ledgerposition,bymeansofshortlengths
ofscaffoldtubeandrightanglecouplers. 3 Thelattermethodhastheadvantageof
facilitatingtheuseofPlatformBrackets(see
Section6).However,itshouldbenotedthat
Note: Infillguardrailsmaybeformedof theplatformwillhaveaslightslopeinone
tubeconnectedtotheStandardsbymeans ofthebaysconnectedtothetower.
ofsuitablecouplersofadequateload
bearingcapacity.
4 Toerectthetowerfollowtheproceduresin
Section2Part1,butuseTransomsofthe
4 Deckingandtoeboardstofillthegapcanbe appropriatelengthinplaceofLedgers.
formedfromtimberofadequatequalityfor
theplatformloadingandofadepththat
doesnotcreateatriphazard. 5 Continueerectingthescaffoldintwo
directionsfromthecorner,inaccordance
withSection2Part1.NB:theStandards
mustbeorientatedsothattheTransomsfit
intoalower‘V’pressingofthebottom
cluster.(ForoldtypeStandardswithwedge
fittingsattheheads,theouterStandards
musthavethewedgesfacingtheoutsideso
thattheydonotobstructthetoeboard.)
FirstIssue2010
15 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Part4-Dismantling andtransferredtoasafeworkingplatform
forloweringtotheground.
procedure
1 Checkthescaffoldisstillinthecorrectly
erectedconditione.g.componentsorties 8 RemoveStandardsconnectedaboveplatform
havenotbeenremovedorincorrectlyfixed level,havingfirstcheckedthatall
andthatguardrailsarestillinthereoriginal componentspreviouslyfixedtothemhave
position.Ifthescaffoldiscompromisedin beenremoved.TheStandardsshouldbe
anyway—seekadvice. transferredtoasafeworkingplatformfor
loweringtotheground.
2 Ensuretheplatformisclearofallloose
materialpriortocommencementof 9 Fromtheadjacentsafeworkingplatform
dismantling. thescaffolderunclipstheharnesslanyard
andrepeatsitems5to8untilallbaysare
dismantledworkingtowardsthefully
boardedtower.
3 Ensurethatthereisaminimumofonefully
boardedtower(i.eboardedandguardrailed
everylift)withinthescaffoldstructureto
allowaccessforremovalofmaterialsand 10 Workingfromthefullyboardedplatform
componentswithinasafeworkingplatform. belowthetopplatformremovethe
Steelstage/Scaffoldboardsfromaboveand
boardouttheplaformbelow(ifitisnota
fullyboardedscaffold).Thesafeworking
4 Alldismantlingoperationsmustbe
platformmustbeaminimumofthree
undertakenwithaminimumoftwo
boardswide.
competantpersons.
11 Repeatitems5to8forthenewtop
5 RemoveDiagonalBracesandanyLedgers
platformlevel.Removethelowerendofthe
andTransomsconnectedtoStandardsabove
DiagonalBracefirstandtransferitandall
thelevelofthetopplatformTheseshould
othercomponentstoasafeworking
thenbetransferredtoasafeworking
platformforloweringtotheground.
platformandloweredtotheground.Refer
toLoweringTechniqueinitem13below.
12 Progressivelydismantlethescaffoldinthe
sequencedescribedabove,onlyremoving
6 Removetoeboardbracketsandtoeboards
tieswhentheywouldpreventfurther
fromthetopplatformandtransfertoasafe
dismantling.
workingplatformandlowertotheground.
G E N U I N E K W I K S T A G E 16
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
section3
safeuseandmaintenance
1 Beforeallowingpeopleormaterialsonthe 8 Becauseoftheincreaseduseofmechanical
scaffoldstructure,ensurethatithasbeen liftingplantonsitethereisanincreased
erectedcorrectlyandcomplieswiththe possibilityforscaffoldingcomponentsto
user’srequirements. becomefouled/caught.Whenusingcranes
orothermechanicalliftingdevicesnearany
scaffoldstructurecareshouldbetakento
2 Ensurethatallpeopleusingthescaffoldare ensurethatnothingcatchesunderanypart
awareofthepurposeforwhichitis ofthescaffold.Otherwiseupliftcouldoccur
intendedtobeusedandthemaximum withpotentiallydangerousconsequences.
loadingtowhichitcanbesubjected.
Particularcareisrequiredifanypartofthe
3 Ensureusersunderstandthatany itembeingliftedisoutofdriver’ssight.
unauthorisedmodificationtothescaffoldor Connectingpinsareavailabletopositively
removalofcomponentscouldcauseasafety fixKwikstageStandardstogetherifthe
hazard.Alterationsorextensionsshouldbe scaffolduser’smethodstatement/risk
carriedoutonlybyacompetentperson. assessmentindicatesthatupliftcannotbe
eliminated.
4 Carryoutregularinspectionstocheckthat
componentshavenotbeenremovedor
damaged,andthatcomponentshavenot
beenremovedandreplacedincorrectly.
5 Providebarriersandwarningnoticesto
preventaccesstoincompletesectionsof
scaffolding.
6 Ensurethatsafeaccessandegressroutes
areprovidedtoallworkingplatforms,and
thatsuchroutes,includingladdersand
stairways,arekeptclear.
7 Donotoverloadplatforms-useproperly
designedloadingtowersandensurethat
craneandforkliftdriversunderstandloading
restrictionsoneachpartofthescaffold
structure.
FirstIssue2010
17 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
section4
loadingdataandtiepatterns
LoadingData Thescaffoldhasbeendesignedtoresist
combinedserviceandwindloadingasspecified
TheinformationgiveninthisSectionisfor inBS1139:Part5:1990“Specificationfor
permissibleloadingonbasicKwikstageAccess materials,dimensions,designloadsandsafety
Scaffoldsconstructedstrictlyinaccordance requirementsforserviceandworkingscaffolds
withthisscaffoldingguide. madeofprefabricatedelements”.
Fordetailsofmaximumheightsofscaffold
• Scaffoldshigherthanthemaximumspecified
refertotheindividualloadingstatedoneachof
thefollowingpages.
• Pavementgantries
• Bridgingoveropeningsinthescaffold
• Arequirementforliftheightsinexcessof
the2mmaximum
• Exposuretoseverewindloading
FirstIssue2010
G E N U I N E K W I K S T A G E 18
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3000
Basicscaffold1.2mwide,withcantileverplatformsformedfrom1or
2BoardPlatformBrackets
ThesegeneralnotesrefertoKwikstagescaffoldswhichareeitherfullyorpartiallyboarded.
ForunboardedscaffoldwithamaximumoftwoworkingplatformsrefertoDetailNo.KS3010.
FirstIssue2010
19 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Platform TieLocationIndicators
Levels
12 SeeNote5
SeeNote3
11
10
Base SeeNote2
FirstIssue2010
G E N U I N E K W I K S T A G E 20
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3001
Basicscaffold1.2mwide,unsheeted,withcantileverplatforms
formedfrom1or2BoardPlatformBrackets
UseofPlatform: Masonrywork,concreteblockwork
andheavycladding
LoadClassificationinaccordancewith Class4
BSEN12811-1:2003
Maximumplatformserviceload 3.00kN/m2
-onelevel:
Maximumadditionalworkingplatform 1.50kN/m2
-onelevel:
Maximumheightofscaffold: 12liftsof2.0mmaximumliftheight
Maximumnumberofboardedlifts: 12
Maximumnumberofcantileverplatforms 12
(atplatformlevel):
Maximumnumberofworkingcantileverplatforms: 2(SeeNote4)
FirstIssue2010
21 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Platform TieLocations
Levels
SeeNote3
12
11
10
Base SeeNote2
Note1 Façadebracingomittedforclarity.
Note2 TransomsandLedgersmustbeplacedinlowestpossible‘V’pressingirrespectiveof
lowestplatformposition.
Note3 Completedscaffoldsmustalwaysbetiedatthetoplift.
Note4 Uptotwolevelsofcantileverplatformsmaybemovedtointermediatelevelsto
provideappropriateaccess.
Theallowableloadonsuchcantileverplatformsis0.75kN/m2.
FirstIssue2010
G E N U I N E K W I K S T A G E 22
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3002
Basicscaffold1.2mwide,unsheeted,withcantileverplatforms
formedfrom1or2BoardPlatformBrackets
FirstIssue2010
23 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Note: Alternative tying pattern for Masonry Scaffold with a restricted height of ten lifts and
ties starting at level 2.
Platform TieLocations
Levels
SeeNote3
10
Base SeeNote2
Note1 Façadebracingomittedforclarity.
Note2 TransomsandLedgersmustbeplacedinlowestpossible‘V’pressingirrespectiveof
lowestplatformposition.
Note3 Completedscaffoldsmustalwaysbetiedatthetoplift.
Note4 Uptotwolevelsofcantileverplatformsmaybemovedtointermediatelevelsto
provideappropriateaccess.
Theallowableloadonsuchcantileverplatformsis0.75kN/m2.
FirstIssue2010
G E N U I N E K W I K S T A G E 24
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3003
Basicscaffold1.2mwide,unsheeted,withcantileverplatforms
formedfrom1or2BoardPlatformBrackets
FirstIssue2010
25 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Platform TieLocations
Levels
SeeNote3
12
11
10
Base SeeNote2
Note1 Façadebracingomittedforclarity.
Note2 TransomsandLedgersmustbeplacedinlowestpossible‘V’pressingirrespectiveof
lowestplatformposition.
Note3 Completedscaffoldsmustalwaysbetiedatthetoplift.
Note4 Uptotwolevelsofcantileverplatformsmaybemovedtointermediatelevelsto
provideappropriateaccess.
Theallowableloadonsuchcantileverplatformsis0.75kN/m2.
FirstIssue2010
G E N U I N E K W I K S T A G E 26
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3004
Basicscaffold1.2mwide,unsheeted,withcantileverplatforms
formedfrom1or2BoardPlatformBrackets
FirstIssue2010
27 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Note: Alternative three lift tying pattern for Heavy Duty scaffold with a restricted height of
eight lifts.
Platform TieLocations
Levels
8 SeeNote3
Base SeeNote2
Note1 Façadebracingomittedforclarity.
Note2 TransomsandLedgersmustbeplacedinlowestpossible‘V’pressingirrespectiveof
lowestplatformposition.
Note3 Completedscaffoldsmustalwaysbetiedatthetoplift.
Note4 Uptotwolevelsofcantileverplatformsmaybemovedtointermediatelevelsto
provideappropriateaccess.
Theallowableloadonsuchcantileverplatformsis0.75kN/m2.
FirstIssue2010
G E N U I N E K W I K S T A G E 28
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3005
Basicscaffold1.2mwide,unsheeted,withcantileverplatforms
formedfrom1or2BoardPlatformBrackets
FirstIssue2010
29 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Platform TieLocations
Levels
11 SeeNote3
10
Base SeeNote2
Note1 Façadebracingomittedforclarity.
Note2 TransomsandLedgersmustbeplacedinlowestpossible‘V’pressingirrespectiveof
lowestplatformposition.
Note3 Completedscaffoldsmustalwaysbetiedatthetoplift.
Note4 Uptotwolevelsofcantileverplatformsmaybemovedtointermediatelevelsto
provideappropriateaccess.
Theallowableloadonsuchcantileverplatformsis0.75kN/m2.
FirstIssue2010
G E N U I N E K W I K S T A G E 30
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3006
Basicscaffold1.2mwide,unsheeted,withcantileverplatforms
formedfrom1or2BoardPlatformBrackets
FirstIssue2010
31 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Platform TieLocations
Levels
11 SeeNote3
10
Base SeeNote2
Note2 TransomsandLedgersmustbeplacedinlowestpossible‘V’pressingirrespectiveof
lowestplatformposition.
Note3 Completedscaffoldsmustalwaysbetiedatthetoplift.
Note4 Uptotwolevelsofcantileverplatformsmaybemovedtointermediatelevelsto
provideappropriateaccess.
Theallowableloadonsuchcantileverplatformsis0.75kN/m2.
FirstIssue2010
G E N U I N E K W I K S T A G E 32
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3007
Basicscaffold1.2mwide,sheeted,withdebrisnetting,withcantilever
platformsformedfrom1or2BoardPlatformBrackets
FirstIssue2010
33 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Platform TieLocations
Levels
SeeNote5
12 SeeNote3
11
10
SeeNote2
Base
Note2 TransomsandLedgersmustbeplacedinlowestpossible‘V’pressingirrespectiveof
lowestplatformposition.
Note3 Completedscaffoldsmustalwaysbetiedatthetoplift.
Note4 Uptotwolevelsofcantileverplatformsmaybemovedtointermediatelevelsto
provideappropriateaccess.
Theallowableloadonsuchcantileverplatformsis0.75kN/m2.
Note5 DebrisNettingmaybeextendedbeyondthetopplatformlevelofthecompleted
scaffoldandbetiedtothetophandrailsorstandards.However,underextreme
windconditionsthestructuralintegrityofthescaffoldmaybeaffected.Following
anyhighwinds,afullinspectionofthescaffoldasrequiredbycurrentlegislation,
mustbecarriedoutpriortoscaffoldbeingplacedbackintouse.Anydefectsfound
bysuchaninspectionMUSTimmediatelybecorrectedbeforethescaffoldis
deemedfitforpurpose.
FirstIssue2010
G E N U I N E K W I K S T A G E 34
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3008
Basicscaffold1.2mwide,sheeted,withcantileverplatformsformedfrom1
or2BoardPlatformBrackets
FirstIssue2010
35 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Platform TieLocations
Levels
SeeNote5
12 SeeNote3
11
10
1
Base SeeNote2
FirstIssue2010
G E N U I N E K W I K S T A G E 36
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3010
Basicunboardedscaffold1.2mwide,withtwocantileverplatforms
formedfrom1or2BoardPlatformBrackets
FirstIssue2010
37 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Sheeting Forthetyingpatternforallsheetedscaffoldsrefer
toKS3008.
Platform TieLocationIndicators
Levels
SeeNote5
12 SeeNote3
11
10
Base SeeNote2
FirstIssue2010
G E N U I N E K W I K S T A G E 38
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3011
Basicunboardedandunsheetedscaffold1.2mwide,withcantilever
platformsformedfrom1or2BoardPlatformBrackets
FirstIssue2010
39 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Platform TieLocations
Levels
30 SeeNote3
29
28
27
26
Tieseverysecondliftbetweenlifts5and27
Base SeeNote2
Note1 Façadebracingomittedforclarity.
Note2 TransomsandLedgersmustbeplacedinlowestpossible‘V’pressingirrespectiveof
lowestplatformposition.
Note3 Completedscaffoldsmustalwaysbetiedatthetoplift.
Note4 Uptotwolevelsofcantileverplatformsmaybemovedtointermediatelevelsto
provideappropriateaccess.
Theallowableloadonsuchcantileverplatformsis0.75kN/m2.
FirstIssue2010
G E N U I N E K W I K S T A G E 40
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3012
Basicunboardedandunsheetedscaffold1.2mwide,withcantilever
platformsformedfrom1or2BoardPlatformBrackets
FirstIssue2010
41 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Note: Alternative tying pattern for Masonry Scaffold with a restricted height of 26 lifts
and ties starting at Level 2.
Platform TieLocations
Levels
SeeNote3
26
25
24
Tieseverysecondliftbetweenlifts4and24
Base SeeNote2
Note1 Façadebracingomittedforclarity.
Note2 TransomsandLedgersmustbeplacedinlowestpossible‘V’pressingirrespectiveof
lowestplatformposition.
Note3 Completedscaffoldsmustalwaysbetiedatthetoplift.
Note4 Uptotwolevelsofcantileverplatformsmaybemovedtointermediatelevelsto
provideappropriateaccess.
Theallowableloadonsuchcantileverplatformsis0.75kN/m2.
FirstIssue2010
G E N U I N E K W I K S T A G E 42
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3013
Basicunboardedandunsheetedscaffold1.2mwide,withcantilever
platformsformedfrom1or2BoardPlatformBrackets
FirstIssue2010
43 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Note: Alternative three lift tying pattern for Masonry Scaffold with a restricted height of ten lifts and
ties starting at Level 1.
Platform TieLocations
Levels
10 SeeNote3
Base SeeNote2
Note1 Façadebracingomittedforclarity.
Note2 TransomsandLedgersmustbeplacedinlowestpossible‘V’pressingirrespectiveof
lowestplatformposition.
Note3 Completedscaffoldsmustalwaysbetiedatthetoplift.
Note4 Uptotwolevelsofcantileverplatformsmaybemovedtointermediatelevelsto
provideappropriateaccess.
Theallowableloadonsuchcantileverplatformsis0.75kN/m2.
FirstIssue2010
G E N U I N E K W I K S T A G E 44
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3014
Basicunboardedandunsheetedscaffold1.2mwide,withcantilever
platformsformedfrom1or2BoardPlatformBrackets
FirstIssue2010
45 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Platform TieLocations
Levels
SeeNote3
20
19
18
17
16
Tieseverythirdliftbetweenlifts4and16
Base SeeNote2
Note1 Façadebracingomittedforclarity.
Note2 TransomsandLedgersmustbeplacedinlowestpossible‘V’pressingirrespectiveof
lowestplatformposition.
Note3 Completedscaffoldsmustalwaysbetiedatthetoplift.
Note4 Uptotwolevelsofcantileverplatformsmaybemovedtointermediatelevelsto
provideappropriateaccess.
Theallowableloadonsuchcantileverplatformsis0.75kN/m2.
FirstIssue2010
G E N U I N E K W I K S T A G E 46
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3015
Basicunboardedandunsheetedscaffold1.2mwide,withcantilever
platformsformedfrom1or2BoardPlatformBrackets
FirstIssue2010
47 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Platform TieLocations
Levels
20 SeeNote3
19
18
17
16
Tieseverythirdliftbetweenlifts5and17
SeeNote2
Base
Note1 Façadebracingomittedforclarity.
Note2 TransomsandLedgersmustbeplacedinlowestpossible‘V’pressingirrespectiveof
lowestplatformposition.
Note3 Completedscaffoldsmustalwaysbetiedatthetoplift.
Note4 Uptotwolevelsofcantileverplatformsmaybemovedtointermediatelevelsto
provideappropriateaccess.
Theallowableloadonsuchcantileverplatformsis0.75kN/m2.
FirstIssue2010
G E N U I N E K W I K S T A G E 48
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tyingpatternforkwikstage
scaffolds-detailno.KS3016
Basicunboardedscaffold1.2mwide,sheetedwithDebrisNettingwith
cantileverplatformsformedfrom1or2BoardPlatformBrackets
FirstIssue2010
49 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
Platform TieLocations
Levels
30 SeeNote5
SeeNote3
29
28
27
Tieseverysecondliftbetweenlifts5and27
1
SeeNote2
Base
Note1 Façadebracingomittedforclarity.
Note2 TransomsandLedgersmustbeplacedinlowestpossible‘V’pressingirrespectiveof
lowestplatformposition.
Note3 Completedscaffoldsmustalwaysbetiedatthetoplift.
Note4 Uptotwolevelsofcantileverplatformsmaybemovedtointermediatelevelsto
provideappropriateaccess.
Theallowableloadonsuchcantileverplatformsis0.75kN/m2.
Note5 DebrisNettingmaybeextendedbeyondthetopplatformlevelofthecompleted
scaffoldandbetiedtothetophandrailsorstandards.However,underextreme
windconditionsthestructuralintegrityofthescaffoldmaybeaffected.Following
anyhighwinds,afullinspectionofthescaffoldasrequiredbycurrentlegislation,
mustbecarriedoutpriortoscaffoldbeingplacedbackintouse.Anydefectsfound
bysuchaninspection MUST immediatelybecorrectedbeforethescaffoldis
deemedfitforpurpose.
FirstIssue2010
G E N U I N E K W I K S T A G E 50
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
tiepatternsfor0.8m
widescaffold
Drawing detail A - Tie pattern A) Tiepatternfor0.8mwide
AllKwikstageAccessscaffoldsmustbetied un-sheetedscaffold.
toapermanentstructureofsufficient
strengthtostabilisethescaffold.
ForKwikstagescaffoldswithaplatform
widthofnogreaterthan0.8m(i.e3boards)
thestabilityofthescaffoldduringerection
isimportant.Thescaffoldshallbetiedin
accordancewithTiePatternsstatedinthis
UserGuide.Thescaffoldcanalternatively
betiedinaccordancewithA(opposite)and
themaximumheightofsuchscaffoldsshould
benotgreaterthanstatedinKS300toKS
3006andKS3010toKS3014.Fordebris
nettedscaffoldsthetiepatternshouldbeas
showninKS3007andforsheetedscaffolds
thetiepatternshouldbeasKS3008
Notes:
1) MinimumSafeWorkingLoadoftiestobe
6.1kNeach.
2) Thetiepatternsshownarebasedonthe
assumptionthatthetiesarewithin
300mmofthenodesindicated.
FirstIssue2010
51 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
section5
bracingrequirements
Bracing requirements Forlongfaçades,bracingshouldreturnto
thebottomofthescaffoldasshown,with
Façadebracingshouldgenerallybe
themaximumnumberofunbracedbays
providedintheformofacontinuouslong
notexceedingfour.
diagonalrunningfromthebottomtothetop
ofthescaffoldasillustratedbelow.
Iftheproportions(length:height)ofthe
scaffoldaresuchthatasinglerunof
diagonalbracingdoesnotreachthetopof
thescaffold,thenfurthersequencesof
bracingmustbeprovided,asshownopposite
untilthetopofthescaffoldisreached.
Note:
Thebottomendofeachbracemustbe
connectedtothe‘V’pressingBELOWthe
topendofthepreviousbrace.
FirstIssue2010
G E N U I N E K W I K S T A G E 52
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
section6
platformbrackets
PlatformBracketsareavailableinthree 5. If2or3BoardPlatformBracketsare
widthstoformcantileverextensionsto beingused,aTieBaroftheappropriate
platformsontheinsideofaKwikstage lengthmustbefittedbeforeany
scaffold.Theyconnectinto‘V’pressingson SteelstageareplacedontheBrackets.
theStandardsinthesamemanneras
theTransoms. 6. ThecurvedlugsontheendsoftheTie
BarengageinholesinthePlatform
1,2or3BoardPlatformBracketsmaybe Bracketswiththehorizontallegofthe
usedon1.2m(fiveboard)wideKwikstage anglesectionpointingoutwards(i.e.
scaffolds.Only1or2BoardPlatform awayfromthescaffold).
Bracketsarepermittedon0.8m(3board)
widescaffolds. NB Asafesystemofworkisrequired
duringinstallationorremovalof
Thesecomponentscanonlybeusedin TieBars.
locationswherethereisnotariskofpeople
falling(e.g.whentheedgeofthe
cantileveredplatformisclosetothefaceof
abuilding).
Steelstageshouldbeusedasthedeckingon 7. OncetheTieBarhasbeenfixed,
PlatformBrackets. Steelstagecanbeplacedinthatbayto
formacompletelydeckedbayof
PlatformBracketsshouldbefittedinthe cantileveredplatform,andthewedges
followingmanner: drivenhome.(TwoorthreeSteelstage
willberequireddependingonthe
1. ConnectaPlatformBracketofthe PlatformBracketbeingused.)
requiredwidthtoa‘V’pressing,atthe
appropriatelevel,onthesideofa Note: TheTieBarisnowlockedin
Standardfacingthebuilding. positionandcannotberemovedwithout
firstremovingoneof
2. Repeattheoperationonan theSteelstage.
adjacentStandard.
8. Continueerectingcantileveredplatforms
3. Ifa1BoardPlatformBracketisbeing intheabovemannerforasmanybaysas
used,placeaSteelstageofthe arerequired,withparticularemphasison
appropriatelengthontheBracketsand theneedtofixTieBarsinthesequence
taphomethewedges. and
methodspecified.
4. Thecantileverplatformforonebayis
nowcompleteanditcanbecontinued 9. AnInternalCornerFiller(CodeNo.9053
alongthescaffoldfortherequired orCodeNo.KAX10017)isavailableshould
numberofbaysinthesamemanner. cantileverplatformsberequiredon
internalcorners.
FirstIssue2010
53 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
section7
ladderandstairaccess
Part 1 - Ladder towers b) FitaLadderAccessTransomcentrally
acrosstheLedgers2mabovethe
1 Whereladderaccesstowersarerequired boardedlift,withthehalfcoupler
carefulconsiderationshouldbegivento attachedtotheoutsideLedgerofthe
theirlocationinthescaffold.The laddertower.Leavethehalfcoupler
followingisrecommended:- looseenoughtoadjusttheposition
oftheTransom.
a) Wheneverpossibleaseparateladder
towershouldbeconstructedleaving c) Placea1.2mSteelstagebetweenthe
theworkingplatformonthescaffold outsideTransomandtheLadder
intact. AccessTransomandensureitisfully
locatedbypushingtheLadderAccess
b) When(a)isnotpossibletheladder Transomupagainstit.Checkitis
towershouldbepositionedonthe squareandtightenthe
endofarunofscaffold,keepingthe halfcoupler.
disruptionoftheworkingplatformto
aminimum.
c) Onlywhen(a)and(b)arenot
practicableshouldconsiderationbe
giventopositioningtheladderaccess
towerinthegeneralrunof
thescaffold.
2 Constructionoftheladdertower
frameworkshouldbeinaccordancewith
theproceduresetoutinSection2ofthis d) Workingfrombelow,fitthesecond
UserGuidetakingcognisanceofthe 1.2mandthree2.4mSteelstageinto
chosenmethodofadvancedguardrail thebay.
requirements.
3 Theerectionsequencethatfollowsis
basedontheladdertowerbeingerected
ina2.4mx1.2mbaybuiltin2mlifts
andusinga3mladdertogiveaccessto
eachlift.
a) Erectthebasicframeworkofthe
laddertowerandfullydeckoutat
thelowesttransomlevel. FirstIssue2010
G E N U I N E K W I K S T A G E 54
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
e) Usinga3mladderasaccess,tieitto
theLadderAccessTransomand
completethe2mliftbyerecting
doubleguardrails,toeboardsandend
toeboardsasapplicabletoall
exposedfacesoftheladdertower.
FirstIssue2010
55 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
7 ladderandstairaccess
4.1 Theerectionsequenceisbasedonthe
stairtowerbeingbuiltwithaccesstothe
workingliftsthatisindependentofthe
a & b
mainaccessscaffold.
a) Erectthebasicframeworkofthestair
toweri.e.threebayslongxtwo0.8m
bayswidex2mlift.Atthelowest
transomlevelfullydeckoutthe
landingbays.
b) FitaStairwayUnitintothecentral
2.4mbay.Thisshouldbelocatedin Note: AlternativelyanindependentStair
theinsidebaynexttothemain Towercanbeerected,Thisshouldbetiedto
scaffold.(A two person operation.) theadjoiningscaffoldoneveryStandardat
alternativelifts.
FixtheStairwayUnittothe0.8m
Transoms,topandbottom,usingtwo
BeamClips.FittwoHandrailUnitsto
theStairwayUnits.(A two person
operation.) c
c) Frombelow,fullydeckoutthelanding
bays2maboveandproceedtothe
nextlift.Fitdoubleguardrailsaround
thesidesofthelandingbays,and
acrossthecentral2.4mbaynextto
themainscaffold.
d) FitaStairwayUnitintheoutsidebay
intheoppositedirectiontotheone
below.Repeattheabovesequence,
d
addingtotheheightofthestairway
andprovidingaccessontotheworking
platformsasnecessary.
Note: Toeboardsarenotnecessaryonthe
landingplatformsifthereareno
materialsthatcouldbedislodged.
G E N U I N E K W I K S T A G E 56
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
1
section8
loadingtower
1 Determinerequiredlocationof
thetower.
UsingtheproceduresinSection2,erect
anintermediateStandardandUniversal
Jackusingfour1.2mInfillTransomsand
twoLoadingTowerIntermediate 2
StandardRestraints.Donotdrivehome
theTransomwedgesatthisstage.
2 ErectfrontStandardsoftowerusing
UniversalJacksand2.4mLedgersinthe
bottom‘V’pressings.Leveltowerby
3 & 4
adjustingthefrontlegUniversalJacks.
Note: AdjustableBaseandHeadJack
(CodeNo.KAX20003orCodeNo.9600)
mustnotbeusedinaloadingtower.
3 Place2.4mLoadingTowerTransomand
sidefaceLedgersatrequired
platformlevel.
4 PlacehookofInfillTiearound
intermediateStandardandmoveforward
untilendbracketpassesoverLoading
TowerTransom‘T’section. 5
Drive home all wedges.
5 PlacetenSteelstageontotowerto
createworkingplatform. 6
6 Takingcognisanceofthechosenmethod
ofadvancedguardrailrequirements,fix
Kwikguardstosidesofworkingplatform.
EnsurethesideoftheKwikguardwith
thetoeboardreturnfacesoutwards.(A
twopersonoperation.)
7 PlaceGuardrail/GateRestraintontopof
verticalanglesofKwikguards.Adjust
positionofhalfcouplersontoprailsof
Kwikguardsuntiltheypassthroughmesh.
Tightencouplers.(Atwo
personoperation.)
7& 8
Note: AnalternativeLoadingTowergateis
available,refertoSection1;Components
FirstIssue2010
57 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
8 loading tower 12
8 WithGuardrail/GateRestraintin closedposition,and
loweredposition,placeapairof refixlock.
LoadingTowerGatesontothefront
Standardsofthetowerbyfittingthe
hingepinsintothefront‘V’pressingson
theStandards.CloseGatesandensure
thatthelockingmechanismlocatesover
theGuardrail/GateRestraint.
9 Attachtubeandcouplerplandiagonal
bracesfromoutsidelegsoftowerto
Notes:
mainscaffoldatplatformlevel.Fix
(i) Maximumloadperplatformis20kN.
3.54mDiagonalBracestoeachsideof
Thisloadistypicallyonepalletof
thetower,usingthelowestavailable
brickswithonetubofmortar
‘V’pressing.
alongside.
8 & 9 Maximumcombinedloadpertoweris
60kN.
(ii) Nopersonsmustbeontheloading
towerplatformwhilstthe
Guardrail/GateRestraintispositioned
attherearoftheplatform.
(iii) A Loading Tower Intermediate
Standard Restraint must be fitted
and left in position at every level of
10 Repeatprocedureforallothertower the main scaffold.
workingplatforms.Connecting pins
should be inserted in all joints between (iv)Tubeandcouplerdiagonalplanbraces
Standards supporting the 2.4m Loading mustbefittedateveryloadingtower
Tower Transom. workingplatformlevelandatno
greaterthanalternateliftsinall
11 To dismantle the loading tower, reverse othercircumstances.
the above sequence having first
checked that the scaffold is still in the (v) Ifaplatformisnotrequiredatany
correctly erected condition. level,theInfillTiemayberemoved
andtheLoadingTowerTransom
Special attention should be given to replacedwitha2.4mLedger.
the Loading Tower Intermediate
Standard Restraints to ensure they
remain in place at all times. Thisshould
especially be checked prior to
dismantling.
12 Toopengates,undolockingmechanism.
WithGuardrail/GateRestraintstillin
position,swinggatesopenuntiltheyare
at180o totheclosedposition.Insert
lockingpinsintothe‘V’pressings
formingtheupperhinges.The
Guardrail/GateRestraintcanthenbe
swungoveruntilitrestsattherearof
theloadingplatform.Toclosegates,
repositionGuardrail/GateRestraint,
removelockingpins,swinggatestothe
FirstIssue2010
G E N U I N E K W I K S T A G E 58
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
section9
kwikstagesafeanchoragepoints
Anchorage points shown are to support full arrest
equipment which includes but is not limited to Safety
Harness, Lanyard and 55mm opening scaffold hook.
WorkingLevel
RecommendedlocationsforattachmentofSafetyHarness
NotsuitableforattachmentofSafetyHarness
FirstIssue2010
59 V A L I D O N L Y F O R
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
appendixA
identificationanduseof
alternativecomponents
InformationinthisAppendixisforcomponents
Loading Tower Gates
whichhavebeenmodifiedorsupersededbut
whichcanstillbeusedfortheapplications Thesegalvanisedgateshavepinstoholdthe
gatesinthe‘open’position.Agravitylatch
specified.
mechanismconnectstotheGuardrail/Gate
Restraintstosecurethegatesinthe‘closed’
Adjustable Base and Head Jack position.
CodeNo. KAX20003
CodeNo. 9600
Weight 4.4kg
Maximumadjustment 515mm
Thiscomponentservesthesamepurposeasthe
UniversalJackexceptthattheappliedaxial
loadmustnotexceed25kN.Coarseadjustment Loading Tower Gates
isbymeansofacaptivepinandholesinthe CodeNo.(pair) KAX10014
Jackstem.Fineadjustmentisbymeansofthe
CodeNo.(pair) 9006
collaronthethreadedsectionofthe
Weight(pair) 38.0kg
stem.
Steelstage
Locking
Plate
CodeNo. N/A
CodeNo. 952000
Weight 11.0kg
FirstIssue2010
G E N U I N E K W I K S T A G E 60
middle east asia pacific
offices offices
UAE Australia
RMDKwikformMiddleEastLLC RMD(Australia)Pty.Ltd.
P.O.Box5801,Sharjah,UAE POBox169,MelrosePark,
Tel:+97165534173Fax:+97165534327 SouthAustralia,5039.
Email:rmd.me@rmdkwikform.com Tel:+61881798200Fax:+61881798201
Email:rmd.australia@rmdformwork.com
Abu Dhabi
RMDKwikform, Hong Kong
POBox259,AbuDhabi,UAE. RMDKwikform,
Tel:+97125502383Fax:+97125502384 22nd FloorEasyTower,
Email:rmd.abudhabi@rmdkwikform.com 609TaiNanWestStreet,CheungShaWan,
Kowloon,HongKong.
Dubai Tel:+85224154882Fax:+85224134797
RMDKwikformMiddleEastLLC Email:rmd.hongkong@rmdkwikform.com
european P.O.Box115480,Dubai,UAE
Tel:+97148856144Fax:+97148856141 Korea
offices Email:rmd.dubai@rmdkwikform.com RMDKwikformCo.Ltd,RMDHouse,
2nd floor,HOBuilding,38-16JamWon-Dong,
United Kingdom Bahrain Seocho-Gu,Seoul,Korea,135-080.
RMDKwikform, RMDKwikform(Almoayed)BahrainLLC Tel:+8225452484Fax:+8225451878
BrickyardRoad,Aldridge, POBox21475,Flat12,Building829, Email:rmd.seoul@rmdkwikform.com
WalsallWS98BW,UK. Road833,Block408,Sanabis,
Tel:+441922743743Fax:+441922743400 KingdomofBahrain New Zealand
Email:info@rmdkwikform.com Tel:+97317382724Fax:+97317382624 RMD(NewZealand)Ltd.
Email:rmd.bahrain@rmdkwikform.com POBox22-316,101-105StationRoad,
Ireland Otahuhu,Auckland6,NewZealand.
RMDKwikform, Lebanon Tel:+6492765955Fax:+6492766732
BallybogganRoad,Finglas,Dublin11,Ireland RMDKwikform. Email:rmd.auckland@rmdformwork.com
Tel:+35318302500Fax:+35318302522 AtcoSari,Hazmieh,Lebanon.
Email:rmd.dublin@rmdkwikform.com HobeikaCentre,3rdFloor. Philippines
Tel:+9615450214Fax:+9615955387 RMDKwikform,
Portugal Email:rmd.lebanon@rmdkwikform.com Unit1102,AnnapolisWilshirePlaza,
RMDKwikform, #11AnnapolisStreet,Greenhill’s,
Av25deAbril,32-1ºEsquerdo, Oman SanJuan,MetroManila,Philippines.
2870-150Montijo,Portugal RMDKwikformOmanLLC Tel:+6327244213Fax:+6327244214
Tel:+351212328688Fax:+351212315715 P.O.Box889,PostCode100 Email:rmd.manila@rmdkwikform.com
Email:rmd.lisboa@rmdkwikform.com Muscat,SultanateofOman
Tel:+96824613571Fax:+96824613573
Spain
RMDKwikformIbéricaSA,
Email:rmd.oman@rmdkwikform.com
south american
PaseodelClubDeportivo,1 Kuwait office
UrbanizaciónLaFinca,Edif.3,1Izda. RMDKwikform,
28223PozuelodeAlarcón,Madrid POBox42094,Shuwaik70651,Kuwait
Tel:+34915556104Fax:+34915554745 Tel:+96524845161Fax:+96524846414 Chile
Email:rmd.madrid@rmdkwikform.com Email:rmd.kuwait@rmdkwikform.com RMDKwikform,
LaEstera811,ParqueIndustrialValle
Saudi Arabia Grande,Lampa,SantiagodeChile
south american RMDKwikformSaudiArabiaLLC Tel:+5627149800Fax:+5627149800
Al-BandariyahCenterOfficeNo611(Unit5) Email:rmd.chile@rmdkwikform.com
office BuildingNo3194,PrinceFaisalBinFahadRoad
AlKhobar34424–8555,KingdomofSaudiArabia
Tel:+96638825444Fax:+96638826604
South Africa
Email:rmd.ksa@rmdkwikform.com
RMDKwikformSouthAfrica(PTY)Ltd,
52JakarandaSt,Hennopspark,
Qatar
Centurion,Pretoria.
RMDKwikform(AlMaha)QatarLLC
Tel:+27126810360Fax:+27126810361
P.O.Box405,Doha,Qatar
Email:rmd.sa@rmdkwikform.com
Tel:+9744653034Fax:+9744653282
Email:rmd.qatar@rmdkwikform.com
FirstIssue2010
R M D K W I K F O R M O F F I C E S
Interserve Industrial
offices
Belvedere Teesside
CrabtreeManorwaySouth, 6EgglestonCourt,StartforthRoad
Belvedere,KentDA176BH RiversidePark,Middlesbrough,TS21RU
Tel:+442083269560Fax:+442083102016 Tel:+441642258500Fax:+441642258501
Dundee
70/72PerrieStreet,Lochee
Dundee,DD22RD
Tel:+441382610511Fax:+441382623923
Edinburgh
600GilmertonRoad
Edinburgh,EH178RY
Tel:+441316722698Fax:+441316722560
Ellesmere Port
Unit2,OlympicPark,PooleHallRoad
EllesmerePort,CH661ST
Tel:+441513737660Fax:+441513564034
Glasgow
35NorthCanalBankStreet
Glasgow,G49XQ
Tel:+441415520003Fax:+441413323614
Grangemouth
22CastleRoad,BanksideIndustrialEstate,
Falkirk,FK27XY
Tel:+441324627430Fax:+441324625834
Leeds
WestlandSquare,WestlandRoad
Leeds,LS115SS
Tel:+441132713841Fax:+441132700048
Newcastle
ChainBridgeRoad,Blaydon-on-Tyne,
TyneandWear,NE215SZ
Tel:+441914142481Fax:+441914990087
Preston
Rough-HeyRoad,Grimsargh
PrestonPR25AR
Tel:+441772796665Fax:+441772703122
FirstIssue2010
I N T E R S E R V E I N D U S T R I A L O F F I C E S
RMDKWIKFORMANDINTERSERVEINDUSTRIAL
The arrangements of photographs may have been assembled by others and therefore not reflect current best working practices or legislation requirements
Our policy is one of continuous improvement and we reserve the right to change, alter or modify
any detail, design, weight, dimension or code without prior notice being given.