Hi Wall Mounted

Decorative Unit

60Hz

1.0 TR to 3.0 TR
( 3.5 KW to 10.5 KW)

Made in UAE ‫صنع في اﻻمارات‬

‫شهادة ا�طابقة الخليجية‬

Made in UAE ‫صنع في اﻻمارات‬


Hi Wall Mounted MSKMP - CWMSD0

Contents
Introduction.................................................................. 2 Specification-60Hz.......................................4-5
Wall Mounted Type ����������������������������������������������������� 3 Dimensional Data.........................................6-8
Standard Features ������������������������������������������������������ 3 Typical Wiring Diagram..............................9-13

Introduction
In early 1974, SKM commissioned pilot production of air conditioning and refrigeration equipment using British and
American product designs and technology.

As part of SKM’s policy of continuous product development, we completed an ambitious factory expansion program in
1984, and entered into a Licensing and Technical Agreement to manufacture most Standard Packaged and Ducted Split
air conditioning units.

SKM decorative Wall Mounted system are designed in accordance with SASO & G- Mark Regulations.
Today, SKM Air Conditioning equipment is totally indigenously designed, engineered & built at SKM Sharjah. We take
pride in the continuous excellent performance of our units in the highly corrosive Gulf environments, and in other specific
applications such as On Shore and Off Shore Oil Installations, Sewage Treatment Plants and Ammunition Depots etc

SKM provides qualified service and stock of replacement parts in all major cities of the G.C.C. countries, Egypt, Jordan,
and Pakistan. See back cover for details or call SKM.

You name it.....We cool it

SKM reserves the right to change, in part or in whole the specifications of its Air Conditioning
Equipment at any time in order to add the latest technology. Therefore, the enclosed information
may change without any prior notice.

2
R-410A
REFRIGERANT

Hi Wall Mounted Features

SKM

Note: all fins are golden except


for 36K-C condenser

Note:
Note:allallfins
finsare
aregolden
goldenexcept
except
،‫عتمد املكيف عىل الزعانف الذهبية‬ for
for36K-C
36K-Ccondenser
condenser
‫وهي طالء مضاد للتآكل عىل سطح‬
‫املبادالت الحرارية وهذا الطالء يضمن‬
‫لك سطح أكرث مقاومة للتآكل واإلستمتاع‬
‫بسنوات أطول من الراحة والتوفري‬
‫ جمبع املبادالت الحرارية مع‬:‫مالحظة‬
‫زعانف ذهبية عدا الوحدة الخارجية للوحدة‬
.36K-C

SKM

SKM

‫الكهربايئ‬

SKM

‫يحافظ‬

SKM

‫خرطوم‬

SKM

Standard Features

Optional Features

SKM S.K.MAir
S.K.M AirConditioning
ConditioningLLC
LLC
33
Hi Wall Mounted MSKMP - CWMSD0

Unit Specifications - Cooling Only


Model MSKMP 12CWMSD0 18CWMSD0 24CWMSD0 30CWMSD0 36CWMSD0
Power supply V-Hz-Ph 220-230V~ 60Hz, 1Ph
Capacity Btu/h 12000 18000 22000 28000 31400
Input W 968 1469 1781 2230 2614
Cooling (T1)
Rated current A 4.33 6.50 7.9 9.70 11.6
EER (Btu/h)/W 12.40 12.25 12.35 12.55 12.00
Capacity Btu/h 10400 15200 18200 24000 26800
Input W 1195 1747 2128 2652 3135
Cooling (T3)
Rated current A 5.28 7.75 9.42 11.75 13.85
EER (Btu/h)/W 8.70 8.70 8.55 9.05 8.55
Max. input consumption W 1490 2120 2570 3380 4100
Max. current A 7.6 10.7 13 17.5 20.5
Compressor Type ROTARY
Input W 58.5 89 60
Indoor Fan Motor Capacitor uF 1.5 3 /
Speed(Hi/Mi/Lo) r/min 1050/950/800 1200/1020/950 1200/1120/1050 1230/1150/1050 1200/1100/1000
Fin type (code) Golden Hydrophilic aluminium
Indoor Coil Tube outside dia.and type mm Φ7,innergroove tube
Coil length x height x width mm 750x336x26.74 820x336x26.74 965x378x40.11 1040x399x40.11
Indoor air flow (Hi/Mi/Lo) m3/h 690/610/490 1160/960/880 1200/1100/1010 1410/1310/1175 1620/1440/1280
Indoor noise level (Hi/Mi/Lo) dB(A) 41/37/32 48/43/40 47/44/42 51/49/45 51/48/45
Dimension(W*D*H) mm 965x215x319 1080x226x335 1259x282x362 1350x272x365
Indoor unit Packing (W*D*H) mm 1045x305x405 1155x415x315 1155x415x320 1340x450x385 1475x460x380
Net/Gross weight kg 11.5/15 14.9/18.7 14.1/17.8 19.9/25.6 21.3/27.3
Input W 77.5 136 150
Outdoor Fan Motor Capacitor uF 2.5 3 4 /
Speed r/min 860 830 910 910 940
Fin type (code) Golden Hydrophilic Aluminium Silver Aluminium
Outdoor Coil Tube outside dia.and type mm Φ5.innergroove tube Φ7,Inner groove tube
Coil length x height x width mm 760x507x23.2 778x663x34.8 1010x756x26.74+598x756x13.37 1000x756x40.11
Outdoor noise level dB(A) 54 57 56 58.5 61
Dimension(W*D*H) mm 770x300x555 845x363x702 946x410x810
Outdoor unit Packing (W*D*H) mm 900x345x585 965x395x765 1090x500x885
Net/Gross weight kg 30.1/33 47.1/51 60.9/65.5 64.2/68.5 68.4/73
Type R410A
Refrigerant
Charge g 850 1300 2200 2500 2600
Design pressure MPa 4.8/1.5 6.0/1.5 4.8/1.5
Liquid side/ Gas side mm(inch) Φ6.35/Φ12.7(1/4"/1/2") Φ6.35/Φ15.9(1/4"/5/8") Φ9.52/Φ15.9(3/8"/5/8") Φ9.52/Φ19(3/8"/3/4")
Refrigerant piping Max. refrigerant pipe length m 20 25
Max. difference in level m 8 10
Connection wiring 3x1.5(Optional) 3x2.5(Optional) 2.5x4(Optional) 4x2.5(Optional) 1.0x4(Optional)
Plug type 3x1.5/(no-plug) 3x2.5/(no-plug) 2.5x3/no-plug 3x2.5/(no-plug) //no-plug
Operation temperature °C 17-30
Indoor(cooling/ heating) °C 17-32/----
Room temperature
Outdoor(cooling/heating) °C 18-52/----
Thermostat type Remote Control (RG57A2/BGEF)
Power Supply Connection IDU ODU
Table 1

Note:
1. The above design and specifications are subject to change without prior notice for product improvement.
2. The values given in the table for the noise level reflect the levels in anechoic chamber.
3. The design conditions comply with SASO-2663-2018 regulation and based on SASO GSO ISO 5151 testing standard:
a) Evaporator entering air conditions of 80.6/66.2ºF (27/19ºC) dry bulb/wet bulb and condenser entering air temperature of 95ºF
(35ºC) dry bulb for T1.
b) Evaporator entering air conditions of 84.2°F/66.2°F (29°C/19°C) dry bulb/wet bulb and condenser entering air temperature of
114.8°F(46°C) dry bulb for T3. (Net Capacity)

4
R-410A
REFRIGERANT

Unit Specifications - Heat Pump


Model MSKMP 12HWMSD0 18HWMSD0 24HWMSD0 30HWMSD0 36HWMSD0
Power supply V-Hz-Ph 220-230V,1Ph,60Hz
Capacity Btu/h 11800 18000 22000 27000 31400
Input W 952 1452 1781 2180 2614
Cooling (T1)
Rated current A 4.17 6.3 7.9 9.67 11.6
EER (Btu/h)/W 12.40 12.40 12.35 12.40 12.00
Capacity Btu/h 10200 15900 18400 23800 26800
Input W 1172 1797 2114 2615 3135
Cooling (T3)
Rated current A 5.09 7.80 9.38 11.60 13.85
EER (Btu/h)/W 8.70 8.85 8.70 9.10 8.55
Capacity W 3300 5100 6450 7750 9000
Input W 943 1645 1792 2095 2455
Heating (H1)
Rated current A 4.09 7.15 7.95 9.3 10.90
COP W/W 3.5 3.1 3.6 3.7 3.65
Max. input consumption W 1490 2120 2500 3500 4100
Max. current A 7.6 10.7 12.6 18 20.5
Compressor Type ROTARY
Input W 58.5 89 60
Indoor Fan Motor Capacitor uF 1.5 3 /
Speed(Hi/Mi/Lo) r/min 1050/950/850 1200/1120/1050 1230/1150/1080 1200/1100/1000
Fin type (code) Golden Hydrophilic aluminium
Indoor Coil Tube outside dia.and type mm Φ7,Inner groove tube
Coil length x height x width mm 750x336x26.74 820x336x26.74 965x378x40.11 1040x399x40.11
Indoor air flow (Hi/Mi/Lo) m3/h 690/600/520 1185/1090/1005 1200/1100/1010 1340/1235/1100 1620/1440/1280
Indoor noise level (Hi/Mi/Lo) dB(A) 40/37/33 49/47/46 50/46/43 51/47/44 51/48/45
Dimension(W*D*H) mm 965x215x319 1080x226x335 1259x282x362 1350x272x365
Indoor unit Packing (W*D*H) mm 1045x305x410 1155x415x320 1340x450x385 1475x460x380
Net/Gross weight kg 11.5/14.9 15.1/18.8 13.9/17.6 20.3/26.1 21.3/27.4
Input W 77.5 150
Outdoor Fan Motor Capacitor uF 2.5 4 /
Speed r/min 860 780 910 940
Fin type (code) Golden Hydrophilic aluminium

Outdoor Coil Tube outside dia.and type mm Ф7,Inner groove tube


910x609x26.74+ 1005x756x26.74+
Coil length x height x width mm 755x504x40.11 1000x756x40.11
540x609x13.37 598x756x13.37
Outdoor noise level dB(A) 55.5 58 58.5 57.5 63
Dimension(W*D*H) mm 770x300x555 890x342x673 946x410x810
Outdoor unit Packing (W*D*H) mm 900x345x595 995x435x750 1090x500x885
Net/Gross weight kg 33.9/36.6 49.2/52.5 62.5/67.3 66.9/71.8 69.8/74.5
Type R410A
Refrigerant
Charge g 1100 1960 2200 2600 2700
Design pressure MPa 4.8/1.5
Liquid side/ Gas side mm(inch) Φ6.35/Φ12.7(1/4"/1/2") Φ6.35/Φ15.9(1/4"/5/8") Φ9.52/Φ15.9(3/8"/5/8") Φ9.52/Φ19(3/8"/3/4")
Refrigerant piping Max. refrigerant pipe length m 20 25
Max. difference in level m 8 10
Connection wiring 1.5x3/0.75x2 1.5x3+0.75x2 2.5x3/0.75x3 2.5x3/0.75x3 1.0x4(Optional)
Plug type 1.5x3/no-plug 2.5x3/no-plug 2.5x3/no-plug 2.5x3/no-plug //no-plug
Operation temperature °C 17~30
Indoor(cooling/ heating) °C 17~32/0~30
Room temperature
Outdoor(cooling/heating) °C 18~52/-7~24
Thermostat type Remote Control (RG57A2/BGEF)
Power Supply Connection IDU ODU

Table 2

Note:
1. The above design and specifications are subject to change without prior notice for product improvement.
2. The values given in the table for the noise level reflect the levels in anechoic chamber.
3. The design conditions comply with SASO-2663-2018 regulation and based on SASO GSO ISO 5151 testing standard:
a) Evaporator entering air conditions of 80.6/66.2ºF (27/19ºC) dry bulb/wet bulb and condenser entering air temperature of 95ºF
(35ºC) dry bulb for T1.
b) Evaporator entering air conditions of 84.2°F/66.2°F (29°C/19°C) dry bulb/wet bulb and condenser entering air temperature of
114.8°F(46°C) dry bulb for T3. (Net Capacity)
c) Evaporator entering air conditions of 68ºF (20ºC) dry bulb and condenser entering air temperature of 44.6/42.8ºF (7ºC/6ºC) dry bulb/
wet bulb for H1.

S.K.MAir
S.K.M AirConditioning
ConditioningLLC
LLC
55
Hi Wall Mounted MSKMP - CWMSD0

Dimensional Data

INDOOR UNIT (Cooling & Heat Pump)

AB6 Panel

H MB1 Panel

W D

Dimensions W D H
Panel
MSKMP mm
12C&H 965 215 319
18C&H, 24C&H AB6 1080 226 335
30C&H 1259 282 362
36C&H MB1 1350 272 365
Table 3

OUTDOOR UNIT- 12K (Cooling Only & Heat Pump)

779 W3
555

H
12

487 W1
300 D 770 W
70 W2
25 B1
88 B2

D2 D3
286

D1
298
322

61.5 A2
H1
60

H2
93

R6

12 A1

6
R-410A
REFRIGERANT

Dimensional Data

OUTDOOR UNIT - 18K (Cooling Only)

OUTDOOR UNIT - 18K (Heatpump)

S.K.MAir
S.K.M AirConditioning
ConditioningLLC
LLC
77
Hi Wall Mounted MSKMP - CWMSD0

Dimensional Data

OUTDOOR UNIT - 24K, 30K, 36K (Cooling Only & Heatpump)

8
R-410A
REFRIGERANT

Typical Wiring Diagram


12K (Cooling Only)

L VERTICAL MOTOR INDOOR


N MOTOR
Y/G(OR GREEN) 2
2
CN6 TRANSFORMER
CN11 CN112
CN4 CN12 CN2 CN3 CN1 OR POWER BOARD 1 2(N) Pressure
(CN_TO)
RED T4/T3 switch
3(COM.) 4(N.O.)
1 CURRENT DETECT
(CN_TIN)
CN15 Pressure

Notes: COMPRESSOR RELAY switch port

BLACK CN14-1(P1/N) RED CAPACITOR


This symbol indicates RED CN14-2 CN20 CN_T3 CN17 CN18 CN5 BLACK

the element is optional, OPTIONAL


(ELECTRONIC HEATER)
(P2/L/CN17)
(Or WHITE)

the actual shape shall 8(4) OVERLOAD


T4 RELAY
BLACK (INTERNAL/
be prevail. Y/G
OPTIONAL
EXTERNAL
DEPENDING RED
ON MODELS)
Wire Contoller BK
JX1 1 2(N) 3 4 DISPLAY C RED
INDOOR UNIT BOARD
TO OUTDOOR UNIT WiFi COMP R(M)
Conto ller
NOTES: FAN
CN602
S CAPACITOR MOTOR
1.The Color Of Power Supply Cord(L N E) Measures Up To

OPTIONAL
The IEC Standards BROWN BLUE Y/G Or BLUE
③ ② ①

、 、 、

) )

Y/G
The India Standards RED BLACK Y/G Or This symbol indicates

、 、

the element is optional ,


The UL Standards BLACK WHITE GREEN

the actual shape shall


2.The Functions In The Rectangle Are Available For Particular Air-condition; be prevail.

INDOOR OUTDOOR

12K (Heatpump)

TO INDOOR UNIT
L VERTICAL MOTOR INDOOR
N MOTOR
Y/G(OR GREEN)

BLACK CN11 CN112


CN6 CN4 CN12 CN2 CN3 CN1
TRANSFORMER
OR POWER BOARD
2
TERMINAL
(CN_TO)
RED 1 2(N) 3 4
2
3(COM.) 4(N.O.)
1 CURRENT DETECT
(CN_TIN)
CN15
T3/
Pressure
Notes:
BLUE(BLACK)
COMPRESSOR RELAY switch OR YELLOW
BLACK
This symbol indicates CN14-1(P1/N)
CN14-2 CN_T3 CN17 CN18 CN5 BLACK OR WHITE
RED(P2/L/CN17) CN13 CN20
the element is optional, OPTIONAL
Pressure
switch port BLACK
(ELECTRONIC HEATER) RED 4-WAY
the actual shape shall BLUE GREEN
YELLOW T4 8(4) BLUE (BLACK)

be prevail.
OR YELLOW
OPTIONAL CAPACITOR
Y/G OVER LOAD RED
Wire Contoller PROTECTION
JX1 1 2(N) 3 4 DISPLAY BLACK OR WHITE
INDOOR UNIT BOARD C
TO OUTDOOR UNIT WiFi
Contoller RED
NOTES: COMPRESSOR
CN602 R(M)
1.The Color Of Power Supply Cord(L N E) Measures Up To

OPTIONAL
S CAPACITOR
The IEC Standards BROWN BLUE Y/G Or
③ ② ①

、 、 、

) )

BLUE
The India Standards RED BLACK Y/G Or

、 、

The UL Standards BLACK WHITE GREEN FAN


This symbol indicates the element is


optional,the actual shape shall prevail MOTOR
2.The Functions In The Rectangle Are Available For Particular Air-condition;

INDOOR OUTDOOR

S.K.MAir
S.K.M AirConditioning
ConditioningLLC
LLC
99
Hi Wall Mounted MSKMP - CWMSD0

Typical Wiring Diagram


18K (Cooling Only)
Notes: To T3
SWING MOTOR VERTICAL This symbol indicates the element TO INDOOR UNIT
SWING MOTOR is optional,the actual shape shall
M M M be prevail. OUTDOOR UNIT
5 5 Notes
1 2(N)
N.O. COM. C_1 C_2 CN1_COMP CN2_COMP
5
12345 12345
T4 This symbol
WHITE
CN_COMP2 12345 12345 indicates
RED RED
WHITE
2 CN10
CN11 the element
M CN6 (OR CN12) TEMPERATURE
is optional,
~ 3 SENSOR
CN4 (CN7) RED BLACK the actual
INDOOR MOTOR
MAIN BOARD shape shall
CNL
CURRENT DETECT
prevail
CNN CAPACITOR
CN_TO CN_TIN CN3 CN2 CN5
CN_T3 1 2 1 2 1 2 1 2 OVERLOAD
1 2 1 2 1 2 1 2 8(4)
8(4or
RELAY BLACK
TRANSFORMER OR OPTIONAL
Y/G POWER BOARD
OPTIONAL
T2_pipe DISPLAY
Wire Contoller
C BLUE
T1_room BOARD WiFi R
COMPRESSOR
Contoller

L N 1 2(N)
S
CN602

POWER INDOOR UNIT NOTES: WHITE


(BLACK) COMPRESSOR
SUPPLY 1.The Color Of Power Supply Cord(L N E) Measures Up To

The IEC Standards BROWN BIUE Y/G Or Y/G CAPACITOR


③ ② ①

、 、 、

) )

The India Standards RED BLACK Y/G Or FAN Y/G


、 、

TO OUTDOOR UNIT
The UL Standards BLACK WHITE GREEN MOTOR

2.The Functions In The Rectangle Are Available For Particular Air-condition;

INDOOR OUTDOOR

18K (Heatpump)

Notes:
This symbol indicates the element
SWING MOTOR
VERTICAL
SWING MOTOR is optional,the actual shape shall TO INDOOR UNIT To T3
M M M be prevail.
N.O. COM. C_1 C_2 CN1_COMP CN2_COMP 5
5
5
1 2(N) 3 4
12345 12345
WHITE 1 2 12345 12345
WHITE
CN_COMP2
CN9 CN10 CN11 BLUE BLACK
RED RED 2 (OR CN12) RED (OR BLACK) TEMPERATURE
M CN6 SENSOR
~ 3
OVERLOAD BLACK
RE LA Y
CN4(CN7) 4-WAY CAPACITOR
INDOOR MOTOR CURRENT DETECT

CNL
MAIN BOARD BLUE
CNN (OR BLACK)
CN_VALVE CN_OUTF CN_TO CN_TIN CN5 BLACK
1 2 CN_T3 1 2 12
CN12 1 2 1 2 8(4)
8(4or7 COMPRESSOR C
TRANSFORMER OR BLUE
Y/G POWER BOARD
Y/G
OPTIONAL
Wire Contoller
R
OPTIONAL
DISPLAY
BOARD S
WiFi FAN Y/G
L N 1 2(N) 3 4 Contoller
WHITE
INDOOR UNIT
CN602
OPTIONAL (OR BLACK) MOTOR
BLACK
POWER NOTES: COMPRESSOR
SUPPLY 1.The Color Of Power Supply Cord(L、N、E) Measures Up To CAPACITOR BLACK
3*2.5mm2 2*0.75mm2 ①The IEC Standards(BROWN、BIUE、Y/G) Or PTCR STARTER
TO OUTDOOR UNIT ②The India Standards(RED、BLACK、Y/G)Or
③ The UL Standards( BLACK、WHITE、GREEN)
2.The Functions In The Rectangle Are Available For Particular Air-condition;

INDOOR OUTDOOR

10
R-410A
REFRIGERANT

Typical Wiring Diagram


24K (Cooling Only)

SWING MOTOR
OPTIONAL

TO M M M OPTIONAL

PC1_1 PC2_1 OXYGEN ENRICHMENT VERTICAL BLACK PTCR


OR ANION GENERATOR
5 5 5 SWING
WHITE WHITE MOTOR BLACK
BLACK
OPTIONAL

CAP1 WHITE(or BLACK)


BLACK RED
INDOOR MOTOR 12345 12345 S
M CN6 CN_ION 12345 12345
~ CN4 CN12(or CN10) CN11 BLUE
OPTIONAL
BLUE BROWN COMP
OPTIONAL
R
CN_N1(or CNN) BLACK
OPTIONAL
RED BLACK(RED) C
CN_L1(or CNL)
MAIN BOARD CN9 PLASAM CAP2 1(3) 2(4)

CURRENT RED A1 A2 RED


DETECT OVERLOAD
RELAY(internal
BLACK
Notes:
or external
CN_COMP1 OPTIONAL
CN_TO CN_TIN CN3 CN2 CN5 RED component)
(or CN_COMP) CN_T3 1(2)3(4) 1 2 1 2 1 2 This symbol indicates the element (Or BROWN)
TEMPERATURE
1(2)3(4) 1 2 1 2 1 2 8(4) is optional,the actual shape shall SENSOR

2(4) be prevail. XT 1 2(N) 3 T4 H-PRO

TRANSFORMER OR
Y/G Y/G POWER BOARD OUTDOOR UNIT
T2 T1 Wire Contoller
DISPLAY
OPTIONAL
BOARD TO INDOOR UNIT To T3
WiFi

1 2(N) 3 4 Contoller
CN602 INDOOR UNIT 1 2(N) 3
OPTIONAL
Or(L N S )
POWER INDOOR UNIT NOTES:
OPTIONAL

SUPPLY 1.The Color Of Power Supply Cord(L、N、E) Measures Up To


①The IEC Standards(BROWN、BIUE、 Y/G) Or
TO OUTDOOR UNIT ②The India Standards( RED、BLACK、Y/G)Or
③ The UL Standards(BLACK、WHITE、 GREEN)
2.The Functions In The Rectangle Are Available For Particular Air-condition;

INDOOR OUTDOOR

24K (Heatpump)

SWING MOTOR VERTICAL


SWING MOTOR
OPTIONAL M OPTIONAL

M
PC1_1 PC2_1 5
WHITE WHITE 5
BLACK CAP1
12345 1 23 4 5
12345 1 2 3 4 5
3/5 CN11
CN6 WHITE
M CN10 BLUE (or BLACK)
~ BLUE
3
INDOOR MOTOR CN4 CODE PART NAME
OPTIONAL BLACK COMP
COMP COMPRESSOR
CN_L1 BLUE BROWN
VALVE CAP1 COMPRESSOR CAPACITOR

Notes:
CURRENT
DETECT OPTIONAL
(CN_L)
MAIN BOARD BLUE
K M1
1(3) 2(4)
OVERLOAD
RELAY FAN2 OUTDOOR FAN
CN_N1
This symbol indicates (CN_N)
RED
RED
CAP2 OUTDOOR FAM CAPACITOR

the element is optional, RED BLUE(OR BLACK)


BLACK A1 A2 XT TERMINAL
BROWN(or RED)
the actual shape shall CN12 OPTIONAL CN5
H-PRO VALVE REVERSING VALVE

be prevail. VALVE OUTF CN_TO CN_TIN


BROWN(or RED) K M1 AC CONTACTOR
1 2 CN_COMP CN_T3 1 2 12
8(4)
Y/G
1 2 1 2
8(4or7
T4 TEMPERATURE
SENSOR

TRANSFORMER OR OPTIONAL
1 2(N) 3 4 5 POWER BOARD Wire Contoller 11 2(N) 3 4 5 XT To T3
DISPLAY
INDOOR OPTIONAL
BOARD OPTIONAL
UNIT WiFi
Contoller TO INDOOR UNIT
POWER SUPPLY CN602

TO OUTDOOR UNIT NOTES:


1.The Color Of Power Supply Cord(L N E) Measures Up To

The IEC Standards BROWN BIUE Y/G Or


③ ② ①

、 、 、

) )

The India Standards RED BLACK Y/G Or


、 、

The UL Standards BLACK WHITE GREEN


2.The Functions In The Rectangle Are Available For Particular Air-condition;

INDOOR OUTDOOR

S.K.MAir
S.K.M AirConditioning
ConditioningLLC
LLC
1111
Hi Wall Mounted MSKMP - CWMSD0

Typical Wiring Diagram


INDOOR UNIT - 30K (Cooling Only)

SWING MOTOR
OPTIONAL
VERTICAL
OPTIONAL
OPTIONAL TO
OPTIONAL
OXYGEN ENRICHMENT M M M SWING
MULTI-FUNCTION OR ANION GENERATOR
OPTIONAL
MOTOR
1 2 SWITCH BOARD CONTROL BOARD 5 5 5 BLACK
Notes:
PC1_1 PC2_1 PTCR
WHITE WHITE 2 BLACK
This symbol indicates the element BLACK
OPTIONAL
OPTIONAL BLACK RED
12345 BLACK
12345
CN_SWM CN32 12345 12345
is optional,the actual shape shall CAP1
CH 5or2 CN_ION be prevail. BLUE R S WHITE(or BLACK)
M CN6 CN10 CN11
~ 3 OPTIONAL BLUE
CN4(CN7) OPTIONAL COMP
INDOOR MOTOR CN_L1 or CN_L3 CN9 BROWN
CURRENT
DETECT CN_L or CN_L4 C
OPTIONAL
CN_N1
MAIN BOARD CN2
OPTIONAL
T1_room CAP2
BROWN (OR RED)
RED 3
1
4
2
RED
RED
OPTIONAL CN_N or CN_N2 A1 A2 C OVERLOAD
(Or BLACK)
T2_pipe Reactance
BLACK RELAY(internal

OPTIONAL CN_TO CN_TIN CN3 RED or external


component)
OPTIONAL
CN_COMP CN_T3 1(2)3(4) 1 2 CN5 RED(BROWN)
TEMPERATURE
1(2)3(4) 1 2 RED Z SENSOR
8(7 or 4)
Y/G 2(4) XT T4 H-PRO

OPTIONAL OUTDOOR UNIT To T3


1 2(N) 3 4
TRANSFORMER DISPLAY Wire Controller

POWER BOARD BOARD OPTIONAL NOTE:


POWER SUPPLY WiFi
INDOOR UNIT 1 2(N) 3
Or (L N 1
Controller

INDOOR UNIT MULTI-FUCTION CONTROL BOX


OPTIONAL )
NOTES:
TO OUTDOOR UNIT 1.The Color Of Power Supply Cord(L、N、E) Measures Up To
①The IEC Standards(BROWN、BIUE、Y/G ) Or
②The India Standards(RED、BLACK、Y/G)Or
③ The UL Standards(BLACK、WHITE、GREEN)
2.The Functions In The Rectangle Are Available For Particular Air-condition;

INDOOR OUTDOOR

INDOOR UNIT - 30K (Heatpump)

SWING MOTOR VERTICAL


SWING MOTOR
PLASMA M M M
Notes: SWITCH
5
BOARD 5 BLACK CAP1
This symbol indicates the element 5 FAN2

is optional,the actual shape shall BLACK WHITE


12345 12345
be prevail. CN_SWM 1 2 12345 12345 X T7
BLUE (or BLACK)

CN11 CODE PART NAME


5 CH CN9 CN10
BLACK BLUE COMP
M CN6 COMP COMPRESSOR
BLUE BROWN
~ COMPRESSOR CAPACITOR
CAP1
CURRENT DETECT VALVE
INDOOR MOTOR OVERLOAD
CN_L1
CN_L MAIN BOARD BLUE
K M1
RED 3(5) 4(6) RED
1 2
RELAY FAN2

CAP2
OUTDOOR FAN

OUTDOOR FAM CAPACITOR


RED
CN_N1 RED BLACK A1 A2 XT TERMINAL
CN_N BROWN(or RED)
X T7 MIDDLE TERMINAL
CN_TO
H-PRO
CN12_VALVE CN12_OUTF CN_COMP CN_TIN
VALVE REVERSING VALVE
CN_T3 1 2 12 BROWN(or RED)
1 2 1 2 TEMPERATURE K M1 AC CONTACTOR
Reactance
T4
SENSOR
H-PRO

RED
TRANSFORMER OR Z NOTE:
Y/G Y/G
POWER BOARD 11 2(N) 3 4 5 XT To T3
OPTIONAL

INDOOR UNIT TO INDOOR UNIT


1 2(N)
3 4 5 NOTES:
1.The Color Of Power Supply Cord(L N E) Measures Up To

POWER
The IEC Standards BROWN BIUE Y/G Or
③ ② ①

、 、 、

) )

SUPPLY
The India Standards RED BLACK Y/G Or

、 、

TO OUTDOOR UNIT
The UL Standards BLACK WHITE GREEN

2.The Functions In The Rectangle Are Available For Particular Air-condition;

INDOOR OUTDOOR

12
R-410A
REFRIGERANT

Typical Wiring Diagram


36K (Cooling Only & Heatpump)

Notes:
This symbol indicates the element
OPTIONAL is optional,the actual shape shall
ION IN FAN M M be prevail.
M
5
5
OPTIONAL CN14
CN12_1CN12_2 CN4
P_1 CN5 MICRO SWITCH
HEATER CN6_1 2
2
CN6_2
2 PLASMA
CN43 CN44
RED
CN2 ROOM TEMPERATURE SENSOR
BLUE(BLACK) L-IN CN8
YELLOW
PIPE TEMPERATURE SENSOR
Y/G N CN9
CN10A
S (CN10)
CN16 OPTIONAL
L N S JX1 Wi-Fi
INDOOR UNIT Contoller
8(4) DISPLAY BOARD
4
OUTDOOR UNIT CN3(CN301)
OPTIONAL
Wire Contoller
OPTIONAL 5

INDOOR

OPTION KM1
3 WHITE
M 1(3) 2(4)
(OR BLACK)
RED RED
VALVE C S
RED A1 A2
BLUE BLUE
3 OPTION
COMP CODE PART NAME
UNIT1 OUTDOOR CONTROL PCB
RT3
COMP COMPRESSOR
CN3 R
5 BLACK
H-PRO
CAP1 COMPRESSOR RUN CAPACITOR
Cn1 BLUE CAP2 OUTDOOR FAN CAPACITOR
CN13 XP1
OPTION RED
XT2 FAN2 OUTDOOR FAN
XS1 RED 1 2 CAP1 XT1 TERMINAL
5 1 2
BLACK XT2、XT3 MIDDLE TERMINAL
CN_FAN CN_T3 RED
BLACK 1 XP1,XS1 CONNECTORS
CN_4V BLACK OPTION
RT3 PIPE TEMPERATURE SENSOR
CT1 BLACK
CN_COMP PTCR KM1 AC CONTACTOR
CT CURRENT INDUCTOR
CN _EA RTH1 UNIT1 BLUE (OR BLACK)
RED TRANS1 TRANSFORMER
CN_S WHITE
CN_EA RTH2 CN1-CN11 PCB SOCKETS
VALVE REVERSING VALVE
CN_N BLACK XT1
CN_HLP1
1 2(N) S L N
RED
CN_HLP2 CN_L
H-PRO
REACTOR
TO INDOOR UNIT POWER SUPPLY Notes:
L-PRO
symbol 1 , 3 and 4 indicates the element is optional,the actual shape shall be prevail.
Symbol 2 indicates compressor internal or external components.

OUTDOOR

S.K.MAir
S.K.M AirConditioning
ConditioningLLC
LLC
13
13
Hi Wall Mounted MSKMP - CWMSD0

NOTES

14
R-410A
REFRIGERANT

NOTES

S.K.MAir
S.K.M AirConditioning
ConditioningLLC
LLC
15
15
Hi Wall Mounted MSKMP - CWMSD0

CONTACT US
HEAD OFFICE

P.O Box: 6004, Sharjah,


United Arab Emirates

Tel: +971 6 514 3333


Fax: +971 6 514 3300

Email: sales@skmaircon.com
Email: info@skmaircon.com

Spare Parts Division


spareparts.skm@skmaircon.com

Service Center
aftersales.skm@skmaircon.com

For SKM Regional Offices & Distributors


visit: www.skmaircon.com

For Saudi Arabia Agent: MB Climate Control


Head Office, Al Khobar- KSA
Phone + 966 13 890 0056
Fax + 966 13 864 5566
-Riyadh Office: 0112914775
-Jeddah Office: 0126639357
Email: ksasales.skm@skmaircon.com
Email: info@thembclimate.com
MB Call Center: 920011595
218/2020
16

You might also like