midas Gen RC Wall Design Result

Company Project Title


Author home File Name C:\...\UND CONF.mgb
1. Design Condition
Design Code : NSR-10 Unit System : kN, m
Wall ID : 104 (Wall Mark : wM0104)
Story-PM, Shear Story
0.02
Material Data : fc = 20684.3, fy = 275790, fys = 275790 KPa
Wall Dim. (Length*Thk) : 9.07*0.16 m

0.16
Vertical Rebar : #3 @304 (AsV = 0.00047 m^2/m)

0.02
2. Applied Loads 0.3048 0.3048

Load Combination : 13
Pu = 649.691 kN, Mcy = 6399.91 kN-m, Mcz = 0.00000 kN-m

3. Axial Forces and Moments Capacity Check


Concentric Max. Axial Load PhiPn-max = 12974.3 kN
Major Axis
Design Axial Load Strength PhiPny = 809.040 kN
Axial Ratio Pu/PhiPny = 0.803 < 1.000 ....... O.K
Design Moment Strength PhiMny = 7846.92 kN-m
Moment Ratio Mcy/PhiMny = 0.816 < 1.000 ....... O.K
Minor Axis
Design Axial Load Strength PhiPnz
Axial Ratio Pu/PhiPnz = 0.000 < 1.000 ....... O.K
Design Moment Strength PhiMnz
Moment Ratio Mcz/PhiMnz = 0.000 < 1.000 ....... O.K

4. P-M Interaction Diagram


P(kN) P(kN)
27500 27500

24500 Major Axis 24500 Minor Axis


21500 21500

18500 18500

15500 15500

12974
12500 12974
12500

9500 9500

6500 6500

3500 3500

0
500
(809,7847)
(650,6400)
500
0 (650,0)
-2500 M(kN-m) -2500
(0,0)
M(kN-m)
10500

14000

17500

21000

24500

28000

31500

35000
3500

7000

120

180

240

300

360

420

480

540

600
60

0 0

5. Shear Force Capacity Check


Applied Shear Force Vu = 472.498 kN (Load Combination : 13)
Design Shear Strength PhiVc+PhiVs = 774.498 + 608.639 = 1383.14 kN
(As-H_req = 0.00040 m^2/m, #3 @350)
Shear Ratio Vu/PhiVn = 0.342 < 1.000 ....... O.K

Modeling, Integrated Design & Analysis Software Print Date/Time : 06/10/2021 22:02
http://www.MidasUser.com
Gen 2019

You might also like