PROJECT SCHEDULE- Q

Name of Project:- ESTIMATE FOR PROPOSED CONSTRUCTION OF 5 CLASSROOM AT GOVT. SHANKAR SAO COLLEGE WARASEONI DISTT. BALAGHAT

PCC No. As per Column 2 ofBN


Format B
Project Cost
Name of "Project Cost
Center
Center" (PCC) ( As per 5 CLASSROOM
( As per Column 2,
Column 8 of Format B
3 & 8 of Format -
B) Built Up Area of Building
587.31
(in Sqm.) :-
BILL OF QUANTITIES (BOQ)
All Amount in Rs.

Sub Item
Unique BOQ No. Item No. Items Name Description of Item Quantity Unit Rate Amount
No.
1 2 3 4 5 6 7 8
CIVIL WORKS SOR ITEMS ( Q1 )
Surface dressing of the ground including
removing vegetation and in-equalities
not exceeding 15 cm deep and disposal
1 2.1 of rubbish, lead up to 50 m and lift up to
1.5 m. all kind of soil

3.31 SQM 803.00 2,657.93

Earthwork in rough excavation by any


means and banking/filling eaxcavated
earth in layers not exceeding 20cm in
depth, breaking clods, watering, rolling
each layer with 1/2 tonne roller or
wooden or steel rammers, and rolling
2 2.35 every 3rd and top-most layer with power
roller of minimum 8 tonnes and dressing
up, in embankments for roads, flood
banks, margingal banks, and guide
banks etc., lead upto 50 m and lift upto
1.5 m: all kind of soil

165.60 CUM 130.00 21,528.00

Earth work in excavation by


mechanical means (Hydraulic
excavator ) /manual means over areas
(exceeding 30cm in depth. 1.5m in width
as well as 10 sqm on plan) including
dressing of sides and ramming of
bottom disposal of excavated earth,
3 2.6 lead up to 50m and lift up to 1.5m,
disposed earth to be levelled and neatly
dressed. (No extra lift is payable if work
is done by mechanical means) all kind
of soil

132.90 CUM 129.00 17,144.10

Earth work in excavation/ by


mechanical means (Hydraulic
Excavator)/ manual means over areas
(exceeding 30 cm in depth, 1.5m in
width as well as 10 sqm on plan)
4 2.7 including dressing of sides and ramming
of bottom disposal of excavated earth,
lead up to 50 m and lift up to 1.5 m,
disposed earth to be levelled and neatly
dressed.

2.7.1 Ordinary rock 14.40 CUM 203.00 2,923.20

Extra for every additional lift of 1.5 m or


part thereof in excavation. (No extra lift
5 2.25 is payable if work is done by mechanical
means)
2.25.1 All kinds of soil. 7.20 CUM 30.00 216.00
Extra for every additional lift of 1.5 m or
part thereof in excavation. (No extra lift
6 2.25 is payable if work is done by mechanical
means)

2.25.2 Ordinary rock 14.40 CUM 53.00 763.20

Providing and laying in position cement


concrete of specified grade excluding
7 4.1 the cost of centering and shuttering - All
work up to plinth level :

With 40mm nominal size graded stone


4.1.2 aggregate.
4.1.2.1 M I5 - Grade concrete 5.60 CUM 4403.00 24,656.80

Nominal Mix -1 Cement : 3 sand : 6


4.1.2.3 graded stone aggregate (M -7.5) 0.68 CUM 3474.00 2,362.32

Providing and laying in position specified


grade of reinforced cement concrete
(with 20mm nominal size graded stone
RCC upto aggregate) excluding the cost of
8 5.1 centering, shuttering, finishing and
plinth
reinforcement - All work up to plinth level
:

M-20 Grade Concrete


5.1.1 M-20
M-20 41.10 CUM 5796.00 2,38,215.60

Reinforcement for R.C.C. work including


straightening, cutting, bending, placing
in position and binding including cost of
binding up to floor two level including
cost of binding wire, all wastages and
lappages/overlaps (overlaps shall be
provided as per requirement of IS :
13920 for ductile detailing, IS : 546 RCC
9 5.16 design & SP 34 Reinforcement detailing)
etc. complete. (Note:-
Spacer bar (chairs) shall be paid
seprately as show in the drawing and as
per direction of Engineer-in-charge.)

Thermo-Mechanically Treated bars.


5.16.6 (TMT) FE-500D conforming to IS : 1786
18484.20 KG 62.90 11,62,656.18

Centering and shuttering in cluding


Centering
strutting, propping etc. and removal of
10 5.9 and form for:
Shuttering
Foundations, footings, bases of
5.9.1 Upto plinth columns, etc. for concrete upto plinth
level
64.50 SQM 190.60 12,293.70

Columns, Pillars, Piers, Abutments,


11 5.9.6 Columns Posts and Struts.
68.95 SQM 471.20 32,489.24
Walls (any thickness) in cluding
attached pilasters butter esses, plinth
12 5.9.2 Walls beams and string courses etc.

Upto plinth Uptoplinthlevel.


5.9.2.1
level 286.20 SQM 219.00 62,677.80
Filling available excavated earth
(excluding hard rock/Ordinary rock) in
Filling trenches, plinth, sides of foundations
available etc. in layers not exceeding 20cm in
13 2.24
excavated depth, consolidating each deposited
earth layer by ramming and watering, lead up
to 50 m and lift upto 1.5 m.
81.11 CUM 72.00 5,839.92

Transportation By Mechanical Transport


14 1.1 including loading , unloading and
stacking.
1.1.2 EARTH 26.69 CUM 207.04 5,525.90

Supplying and filling in plinth under floors


Under floor including watering ramming
15 2.27 consolidating in layers not exceeding
filling
20cm in depth and dressing complete.
87.99 CUM 300.00 26,397.00
2.27.1 With hard muram having CBR >12 % at
under floors including watering, ramming
and compacting (minimum compaction
Hard 95% of MDD) in layers not exceeding
muram 20cm in thickness and dressing
hard copra complete. (Note:- maximum thickness of
this layer to be provided shall be 30cm)

Total Qty

2.26 Supplying and filling in plinth with


Under floor crusher stone dust / coarse sand under
16 filling stone floors including, watering, ramming and
dust compacting in layers not exceeding

58.65 CUM 672.00 39,412.80

Providing and laying in position cement


concrete of specified grade excluding
C.C. upto
17 4.1 the cost of centering and shuttering - All
plinth level
work upto plinth level :

With 40 mm With 40mm nominal size graded stone


4.1.2 aggregate.
metal
M-10 Nominal (Mix -1 Cement : 3 sand :
6 graded stone aggregate)

4.1.2.2 M-10

29.33 CUM 3808.00 1,11,688.64

Making plinth protection 50mm thick of


cement concrete grade M10 over 75mm
bed of dry metal ballast 40mm nominal
Plinth
size well rammed and consolidated and
18 4.17 protection filled with sand including finishing the top
by C.C. smooth (with 20mm nominal size graded
stone aggregate.)
90.00 SQM 351.00 31,590.00

Providing and laying factory made


machine pressed precast cement
concrete interlocking paver block of any
Concrete shape and size conforming to IS:15658-
19 11.66 interlocking 2006 and ISI marked of 60 mm
paver block thickness, M-30 grade with grey cement
and pigment all as specified. Made by
block making machine with strong
vibratory compaction, laid in required 90.00 SQM 586.00 52,740.00
colour and pattern over and including
Reinforced cement concrete work (with
20 mm nominal size graded stone
aggregate) in walls (any thickness),
RCC in walls, including attached pilasters, buttresses,
20 5.2 columns, plinth and string courses, fillets,
pillars etc columns, pillars, posts and struts etc.
above plinth level and upto floor two
level excluding cost of centering,
shuttering, finishing and reinforcement:
M-20 Grade Concrete
5.2.1 M-20

27.80 CUM 5865.00 1,63,047.00

Centering Centering and shuttering in cluding


21 5.9 and strutting, propping etc. and removal of
Shuttering form for:
Columns, Pillars, Piers, Abutments,
5.9.6 Columns
Posts and Struts. 261.94 SQM 471.20 1,23,426.13

Reinforced cement concrete work (with


20 mm nominal size graded stone
aggregate) in beams, suspended floors,
roofs having slope of any degree
RCC in
landings, balconies, shelves, chajjas,
beams, lintels, bands, plain window sills,
22 5.3 floors, staircases and spiral staircases above
staircases plinth level and upto floor two level
etc excluding the cost of centering,
shuttering, finishing and reinforcement in
concrete grade.

5.3.1 M-20 M-20 Grade Concrete


108.62 CUM 6155.00 6,68,556.10
Centering Centering and shuttering in cluding
23 5.9 and strutting, propping etc. and removal of
Shuttering form for:
5.9.5 Lintels, Lintels, beams, girders, bressumers and 271.48 SQM 356.00 96,646.88
cantilevers

Centering Centering and shuttering in cluding


24 5.9 and strutting, propping etc. and removal of
Shuttering form for:
Suspended Suspended floors, roofs, landings,
5.9.3 466.76 SQM 439.00 2,04,907.64
floors, roofs balconies
Centering and
and access platform.
shuttering in cluding
Centering strutting, propping etc. and removal of
25 5.9 and form for:
Shuttering

Weather Weather shade, Chajjas, corbels etc.,


5.9.19 shade and including Edges.
chajjas 27.62 SQM 534.20 14,754.60

Centering Centering and shuttering in cluding


26 5.9 and strutting, propping etc. and removal of
Shuttering form for:
5.9.7 Staircase Stairs, (excluding landings) except spiral-
32.22 SQM 435.70 14,038.25
Staircases.
Brick work with fly ash lime bricks
(FALG Bricks) conforming to IS:12894-
2002, in super structure above plinth
level up to floor II level in : Brick work
23 6.7 with fly ash lime bricks (FALG Bricks)
conforming to IS:12894-2002, in
super structure above plinth level up to
floor II level in :

having 50 kg I cmz average


6.7.3 compressive
strength
Cement mortar 1:6 (1 cement : 6 sand)
6.7.3.2
77.00 CUM 4936.00 3,80,072.00
Half brick masonry with fly ash lime
24 6.15 Gypsum bricks (FALG bricks)
conforming to IS : 12894, in super
structure above plinth and upto floor two
Having 50 kg/cm2 average compressive
6.15.3
strength
Cement mortar 1:4 (1 cement : 4 sand)

6.15.3.2

4.09 SQM 459.00 1,877.31

Providing and fixing aluminium work for


doors, windows, ventilators and
partitions with extruded built up
standard tubular sections/ appropriate
z sections and other sections of
approved make conforming to IS: 733
Aluminium and IS: 1285, fixing with dash fasteners
work for of required dia and size, including
doors, necessary filling up the gaps at
25 21.1
windows, junctions, i.e. at top, bottom and sides
ventilators with required EPDM rubber/ neoprene
& partitions gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and
jointed mechanically wherever required
including cleat angle, Aluminium snap
beading for glazing I paneling, C.P.
brass I stainless steel screws, all
complete as per architectural drawings
21.1.1 Fixed and fixed
For the directions
portion. of Engineer-in-
Powder coated aluminium (minimum
thickness of powder coating 50 micron)
21.1.1.2
144.00 KG 322.00 46,368.00

For shutters of doors, windows and


ventilators including providing and fixing
hinges/ pivots and making provision for
fixing of fittings wherever required
21.1.2 including the cost of EPDM rubber I
neoprene gasket required (Fittings shall
be paid for separately).

Powder coated aluminium (minimum


thickness of powder coating 50 micron)
21.1.2.2
96.00 KG 345.00 33,120.00

Providing and Fixing decorative high


pressure laminated sheet of plain / wood
grain in gloss / matt / suede finish with
high density protective surface layer and
Laminated reverse side of adhesive bonding quality
26 9.134 conforming to IS : 2046 Type S including
sheet
cost of adhesive of approved quality.

9.134.2 1.0MM 1.0 mm thick. 35.28 SQM 691.00 24,378.48

Providing and fixing glazing in aluminium


Glazing in door. window. ventilator shutters and
aluminium partitions etc. with EPDM rubber/
door, neoprene gasket etc. complete as per
27 21.3 window, the architectural drawings and the
ventilator directions of engineer-in-charge . (Cost
shutters and of aluminium snap beading shall be paid
partitions in basic item) :

With float glass panes of 4.0 mm


21.3.1 4.0 mm thickness (weight not less than 10
kg/sqm) 24.00 SQM 774.00 18,576.00

Extra for Add extra for providing and fixing


28 21.4 froasted froasted glass instead of float glass
glass
With glass panes of 4.0 mm thickness
21.4.1 4.0 mm (weight not less than 10 kg/sqm)
24.00 SQM 259.00 6,216.00

9.43 Providing and fixing M.S. grills of


required pattern in frames of windows
M.S. grills etc. with M.S. flats, square or round bars
28 and etc. including priming coat with approved
windows steel primer all complete.

9.43.1 Fixed to Fixed to steel windows by welding.


steel
windows 360.00 KG 91.00 32,760.00

9.18 Providing and fixing lSI marked flush


door shutters confonning to IS: 2202
shutters (Part I) decorative type, core of block
decorative board construction with frame of 1st
type 1st class hard wood and well matched teak
class hard 3 ply veneering with vertical grains or
29
wood and cross bands and face veneers on both
well faces of shutters of such as duro board,
matched century or equivelant make.
teak 3 ply

9.18.1 35 mm butt 35 mm thick including lSI marked


hinges 35.28 SQM 2600.00 91,728.00
Stainless Steel butt hinges with
9.21 Extra for providing lipping with 2nd class
Extra for teak wood battens 25 mm minimum
30
lipping depth on all edges of flush door shutters
35.28 SQM 401.00 14,147.28
(over all area of door shutter to be

9.24 Extra for cutting rebate in flush door


shutters (Total area of the shutter to be
measured).
Extra for
31
rebate

35.28 SQM 93.00 3,281.04

10.17 Providing and fixing circular/ Hexagonal


M.S. box cast iron or M.S. sheet box for ceiling fan
32 for ceiling clamp of internal dia 140mm, 73mm
fan height, top lid of 1.5mm thick M.S. sheet
with its top surface hacked for proper
36.00 EACH 148.00 5,328.00
bonding, top lid shall be screwed into the

13.8 6 mm 6 mm cement plaster of mix : 1:3 (1


33 cement cement : 3 sand)
plaster
1043.41 SQM 96.00 1,00,167.36

34 13.1 12 mm cement plaster of mix :


13.1.2 1:6 (1 cement : 6 sand) 126.99 SQM 138.00 17,524.62

13.7 18 mm 18 mm cement plaster in two coats


cement under layer 12 mm thick cement plaster
plaster cm 1:5 (1 cement : 5 sand) finished with a
1:5 & 1:3 top layer 6mm thick cement plaster 1:3
35 (1 cement : 3 sand) finished rough with
rough
finished sponge.
with
sponge 623.21 SQM 236.00 1,47,077.56

12.26 Providing gola 75x75 mm in cement


36 Gola concrete 1:2:4 (1 cement : 2 sand : 4
stone aggregate 10mm and down
grade) including finishing with cement 75.80 RM 99.00 7,504.20
13.4 12 mm 12 mm cement plaster finished with a
37 cement floating coat of neat cement ofmix:
plaster
13.4.2 1:04 1:4 (I cement: 4 sand) 18.84 SQM 185.00 3,485.40

Providing for plaster drip course/ groove


38 5.24
in plastered surface or moulding to 50.40 RM 18.50 932.40
R.C.C. projections.
Providing and laying rectified Glazed
Rectified
Ceramic floor tiles 300x300 mm or more
39 11.50 ceramic
(having thickness 9 to 10mm) of 1st
floor tiles
quality conforming to IS : 15622 of 44.52 SQM 644.00 28,670.88
approved make in all colours white,
Providing and fixing Ceramic glazed wall
tiles 300x450 mm or more (having
thickness 6 to 7 mm) of 1st quality
conforming to IS: 15622 of approved
make in all Colours& shades, except
burgundy, bottle green, black laid on
Ceramic 12mm thick bed of Cement Mortar 1:3 (1
40 11.49 glazed wall Cement: 3 sand)preprad same day
tiles when mortar is still green jointed with
grey cement slurry @3.3 kg per sqm
including pointing the joints with white
cement and matching pigments etc.,
complete.
75.06 SQM 776.00 58,246.56

11.35 Kota stone slab flooring over 20 mm


(average) thick base laid over and
jointed with grey cement slurry mixed
with pigment to match the shade of the
Kota stone slab including rubbing and polishing
41
flooring complete with base of cement mortar 1 :
4 (1 cement : 4 sand) 25 mm thick.(Area
of slab to be over 0.25 sqm)

440.47 SQM 930.00 4,09,637.10

11.37 Kota stone Kota stone slabs in risers of steps,


42 in risers, skirting, dado and pillars laid on 12 mm
skirting, 13.25 SQM 942.00 12,481.50
(average)
10-12 mm thick
thick cement mortar 1:3 (1
11.37.1 10-12 mm
thick
Extra for pre finished nosing in treads of
Extra for
43 11.46 steps of Kota stone/ sand stone slab.
nosing
SQM 490.47 39.00 19,128.33
10.12 Pressed Providing and fixing pressed steel door
44 steel door frames conforming to IS: 4351
frames manufactured from commercial mild
steel sheet including hinges, jamb, lock
10.12.2 Profile C of 1.60mm thick single rebate
Profile C of size 100mmx.50mm
size
100mmx50
mm single
rebate
10.12.2.2 Fixing with adjustable lugs with split
Fixing with
end tail to each jamb.
adjustable
lugs
SQM 61.60 1206.00 74,289.60
10.27 Glass Providing and fixing glass panes/ steel
panes/ sheet/ Fibre sheet with putty and
45
steel sheet/ glazing clips in steel doors, windows,
fibre sheet clerestory windows all complete.
4.0 mm
10.27.1 With 4.0 mm thick glass panes. 147.20 SQM 792.000 1,16,582.40
glass

4.2 C.C. upto Providing and laying cement concrete in


46 floor two retaining walls, return walls, walls (any
level thickness) including attached pilasters,
4.2.1 With 20mm nominal size graded stone
With 20mm
aggregate
metal
4.2.1.3 M-15 M I5 - Grade concrete 1.03 CUM 4714.00 4,855.42

13.41 Providing and applying white cement


based putty of average thickness 1 mm,
of approved brand over the plastered
wall surface to prepare the surface even
and smooth i/c all cost of material,
White labour and scaffold etc in all position
47 cement complete.
based putty Note : Putty shall be applied only on the
internal walls, for application on the
exterior walls prior permission of
APD/Chief Engineer will be required.

-295.90 SQM 74.00 21,896.60

13.54 Finishing walls by any mechanical or


Deluxe
manual means with Deluxe Multi surface
multi
48 paint system for interiors and exteriors
surface
using Primer as per manufacturers
paint
specifications :
13.54.3 Two or more coats applied on walls @
1.25 ltr/10 sqm. Over and including one
13.54.3
coat of Special primer applied @ 0.75 ltr
/ 10 sqm. -259.15 SQM 81.00 20,991.15

13.48 Distempering with 1st quality acrylic


distemper (ready mixed) of approved
Acrylic
49 manufacturer, of required shade and
emulsion
colour complete, as per manufacturer's
specification.
13.48.1 Two coats Two or more coats on new work. 1033.56 SQM 56.00 57,879.36

13.64 Synthetic Painting with synthetic enamel paint of


enamel approved brand and manufacture to
50
paint on give an even shade: Two or more coats
new work on new work. :
229.88 SQM 53.00 12,183.64

13.57 Painting on G.S. sheet with synthetic


enamel paint of approved brand and
Synthetic manufacture of required colour to give
emulsion an even shade: New work (two or more
51
Paint on coats) including a coat of approved steel
G.S. sheet primer but excluding a coat of mordant
solution. :

126.00 sqm 55.00 6,930.00


Providing and fixing ISI marked
stainless steel door latchs with
52 9.68
necessary screws etc complete.

9.68.2 250x20x6mm 30.00 EACH 173.00 5,190.00

53 9.65 Providing and fixing ISI marked stainless


steel sliding door bolts with nuts and
9.65.1 300x16mm 30.00 EACH 389.00 11,670.00
9.65.2 250x16mm 16.00 EACH 326.00 5,216.00

Providing and fixing ISI marked stainless


steel tower bolts black finish ( barrel type
54 9.66 ) with necessary screws etc. complete :

9.66.1 250X10 MM 23.00 EACH 148.00 3,404.00

Providing and fixing ISI marked stainless


S.S. steel handles with necessary screws
55 9.69
handles etc. complete :

9.69.1 125 mm 125mm 46.00 EACH 60.00 2,760.00

Stainless Providing and fixing stainless steel


steel hanging type floor door stopper with
55 9.76
hanging necessary screws etc. complete :
type floor 23.00 EACH 103.00 2,369.00

9.169 Providing and fixing factory made 100%


solid wood plastic composite (WPC)
door frame made from wood plastic
composite (single extruded process)
material withProviding and fixing factory
made single extruded WPC(Wood
Factory Polymer Composite) solid
made solid door/window/ceosetory windows and
wood plastic other frames/chowkhat comprising of
56
composite virgin polymer of K value 58-60
(WPC) (Suspension Grade), calcium carbonate
doorframes and natural fibers (wood powder/ rice
.husk/wheat husk) and non toxic
additives (maximum toxicity index of 12
for 100 gms) fabricated with miter joints
after applying PVC solvent cement and
screwed with full body threaded star
headed S.S. screws having minimum
9.169.2 100 mm X50 densityrebate
Single of 750(100
kg/m3mm and screw
X50 mm)
mm METER 40.00 720.00 28,800.00

9.200 Providing and fixing factory made


integral PVC flush door shutter made
from rigid PVC foam sheet (Single
Factory Extruded) with density not less than 600
made kg/cum, conforming to IS: 2380 part 14
integral for screw holding strength with Celluka
57
PVC flush finish surfaces on both sides at the
door manufacturing process itself,
shutter manufactured by an ISO : 9001 -2000
certified company.

9.200.1 24 to 25 24 to 25 mm thick plain solid PVC flush


mm door shutter 13.44 SQM 2250.00 30,240.00

Providing and fixing L-iron or T-iron


frames for doors, windows and
ventilators of mild steel L-section or T-
T-iron frames sections, joints mitred and welded,
for doors,
58 10.11 including fixing of necessary butt hinges
windows and
and screws and applying a priming coat
ventilators
of approved steel primer.

Fixed with
10.11.2 Fixing with carbon steel galvanised dash
dash fastener
fastener of required dia and size (to be
RM 260.00 77.00 20,020.00
10.25 Providing and fixing stainless steel (
Grade 304) railing made of Hollow
tubes, channels, plates etc. including
welding, grinding, buffing, polishing and
making curvature (wherever required)
and fitting the same with necessary
stainless steel nuts and bolts complete
i/c fixing the railing with necessary
Stainless accessories and stainless steel dash
59
steel railing fasteners , stainless steel bolts etc., of
required size, on the top of the floor or
the side of waist slab with suitable
arrangement as per approval of
Engineer-in-charge. ( for payment
purpose only weight of stainless steel
members shall be considered excluding
fixing accessories such as nuts, bolts,
fasteners etc.)
KG 144.00 423.000 60,912.00
10.2 Structural steel work using M.S. flats,
angles, channels I-section, H-section
Structural etc. riveted, bolted or welded in built up
steel work sections, trusses and framed work,
60
built up including cutting, hoisting, fixing in
sections position and applying a priming coat of
approved steel primer all complete.
1250.00 KG 69.00 86,250.00

13.52 Finishing walls by any mechanical or


manual means with Acrylic Smooth
exterior paint (Economy Exterior) of
required shade including all scaffolding.
Premixed New work (Two or more coat applied
formulated @1.67ltr/10sqm over and including one
one coat coat undiluted exterior waterproofing
61
gypsum coating @ 2.39 litre/10 sqm with crack
lightweight bridging ability of upto 0.5mm on
plaster horizontal surfaces with an elongation of
150% and water proofing of upto 3 bars
on vertical surface

446.30 SQM 138.00 61,589.40


13.53 Finishing walls by any mechanical or
manual means with Premium Acrylic
Smooth exterior paint (Premium exterior)
of required shade including all
Premium scaffolding. New work (Two or more
acrylic coat applied @1.67ltr/10sqm over and
smooth including one coat undiluted exterior
exterior waterproofing coating @ 2.39 litre/10
paint sqm with crack bridging ability of upto
(premium 0.5mm on horizontal surfaces with an
exterior) elongation of 150% and water proofing
of upto 3 bars on vertical surface)

85.30 SQM 130.00 11,089.00


21.19 Heat /light Providing and fixing 50 micron thick
62 control film Frosted heat /light control film to
reflective window/door glazing as marketed 21.60 SQM 448.00 9,676.80

21.9 Filling the gap in between aluminium


Silicon frame and adjacent RCC/ Brick/ Stone
63
sealant work by providing weather silicon
sealant over backer rod of approved
51.00 RM 53.00 2,703.00

5.31 Extra for R.C.C. work above floor two


Extra for level for each floors or part thereof.
R.C.C.
64
above floor
two level

CUM 3.48 117.30 408.20


4.25 123.01 522.79
Extra for Extra for R.C.C. work above floor two
R.C.C. above level for each floors or part thereof.
5.31
floor two
level
Column above RL2 9.07 58.65 531.96
Roof Slab above RL2
39.75 61.55 2,446.61
Reinforcem Add extra for providing reinforcement
ent above above Floor two level for every
5.17 additional floor or part there of.
floor two
level
KG 5370.20 0.20 1,074.04
Reinforcem Add extra for providing reinforcement
above Floor two level for every
ent above
5.17 additional floor or part there of.
floor two
level

KG 5370.20 0.20 1,074.04

Extra for brick work in super structure,


Extra for above floor II level for every additional
brick work floor or part there respective item.
6.11
above floor
two level

CUM 26.76 98.72 2,641.75


Add extra for providing reinforcement
Reinforcem
above Floor two level for every
ent above
65 5.17 additional floor or part there of.
floor two
level

KG 850.30 0.20 170.06

Extra for Extra for brick work in super structure,


brick work above floor II level for every additional
66 6.11
above floor floor or part there respective item.
two level
CUM 17.32 98.72 1,709.83
Providing and fixing 1mm thick M.S.
sheet door with frame of 40x40x5mm
M.S. sheet angle iron and 3mm M.S. gusset plates
door and at the junctions and comers, all
67 10.5
angle iron necessary fittings complete, including
frame applying a priming coat of approved
steel primer.

Using M.S. angels 40x40x6mm for


With angles
10.5.1 diagonal braces
braces
SQM 2.10 2604.00 5,468.40
Kota stone slabs 20 mm thick in risers of
steps, skirting, dado and pillars laid on
Kota stone 12 mm (average) thick cement mortar
in risers, 1:3 (1 cement 3 sand) and jointed with
68 11.37 skirting, grey cement slurry mixed with pigment
dado and to match the shade of the slabs,
pillars including rubbing and polishing
complete.for indoor

10-12 mm 10-12 mm thick


11.37.1
thick Sq.m. 0.53 942.00 499.26

Providing and laying in position cement


concrete of specified grade excluding
C.C. upto the cost of centering and shuttering - All
69 4.1
plinth level work up to plinth level :

4.1.3 M-15 With Fly ash.


1:2Y2:4:I1 (1 ordinary portland cement :
2Y2 fly ash : 4 sand : I1 graded stone
4.1.3.2 1:2½:4:11
aggregate 40 mm nominal size)
CUM 7.78 3150.00 24,507.00
22.3 Providing and laying water proofing
treatment to vertical and horizontal
surfaces of depressed portions ofW.C.,
kitchen and the like consisting of : 4 1st
course of applying cement slurry @ 4.4
Kg/sqm mixed with water proofing
Water compound conforming to IS 2645 in
proofing recommended proportions including
treatment rounding off junction of vertical and
70 four course horizontal surface. 5 llnd course of20mm
blown cement plaster 1:3 (1 cement: 3 sand)
bitumen mixed
treatment with water proofing compound in
recommended roportion including
rounding off junction of vertical and
horizontal surface. 6 Illrd course of
applying blown or residual bitumen
applied hot at I.7 Kg. per sqm of area.
d) IVth course of 400 micron thick PVC SQM 19.44 440.00 8,553.60
12.27 Making khurras 45x45 em with average
minimum thickness of 5 cm cement
concrete 1:2:4 (1 cement : 2 sand :4
graded stone aggregate of 20 mm
71 Khurras nominal size) over P.V.C. sheet
1mx1mx400micron, finished with 12mm
cement plaster 1:3 (1 cement: 3 sand)
and a coat of neat cement rounding the
edge and making and finishing the
EACH 10.00 156.00 1,560.00
22.14 Grading roof for water proofing
72 Roof grading
treatment with
22.14.1 Cement concrete 1:2:4 (1 cement: 2
sand: 4 graded stone aggregate 20 mm
C.C. 1:2:4
nominal size)

CUM 14.40 6569.00 94,593.60

22.6 Providing and laying water proofing


treatment on roofs of slabs by applying
cement slurry mixed with water proofing
cement compound consisting of
applying :
(c) after surfuce preparation, first layer of
Water slurry of cement @ 0.488 kglsqm mixed
proofing with water proofing cement compound
treatment @ 0.253 kglsqm.
73
Fibre glass (d) laying second layer of Fibre glass
cloth and cloth when the first layer is still green.
cement slurry Overlaps ofjoints of fibre cloth should
not be less than 10 em.
(e) third layer of 1.5 mm thickness
consisting of slurry of cement @ 1.289
kglsqm mixed with water proofing
cement compound@ 0.670 kglsqm and
sand @ 1.289 kglsqm. This will be
allowed to air cure for 4 hours followed SQM 288.00 338.00 97,344.00
4.12 SOR Item No 4.12 Page No. 52 for
Extra for providing and mixing proofing material
74 water as IS standard in cement concrete work
proofing in c.c quantity as prescribed by the
manufacture
CUM 171.05 44.00 7,526.20

13.50 Water
SOR Item No 13.53 Page No. 249
75 proofing Finishing walls with water proofing
cement paint cement paint of required shade:
CUM 242.01 48.00 11,616.64
17.2 Providing and fixing white vitreous china
pedestal type water closet (European
type W.C. pan) with seat and lid, 10 litre
W.C. low level white P.V.C. flushing cistern,
European including flush pipe, with manually
76 type PVC controlled device (handle lever),
flushing conforming to IS : 7231, with all fittings
cistern and fixtures complete including cutting
and making good the walls and floors
wherever required :

17.2.1 White W.C. pan with ISI marked white solid


plastic seat plastic seat and lid
cover and
lid 8.00 EACH 3036.00 24,288.00

Providing and fixing CP jet assembly to


including connection etc complete.
77 18.61

8.00 EACH 375.00 3,000.00

Toilet
17.70 Providing and fixing toilet paper holder :
78 paper
holder
17.70.1 C.P. brass
C.P. brass
8.00 EACH 340.00 2,720.00
Wash
79 17.11 Providing and fixing wash basin with C.I.
basin
17.11.2 brackets,
White 15 mm
Vitreous C.P.Wash
China brass basin
pillar size
630x450 630x450 mm with a single 15 mm C.P.
mm flat brass pillar tap.
back single
pillar cock
(china clay)
8.00 EACH 2187.00 17,496.00

17.64 P.V.C. Providing and fixing P.V.C. waste pipe


80
waste pipe for sink or wash basin
17.64.1 Semi rigid pipe
Rigid
17.64.1.1 32 mm 32 mm 8.00 EACH 87.00 696.00

18.32 Providing and fixing C.P. brass long


C.P. brass nose bib cock of approved quality
81 long nose conforming to IS standards and
bib cock weighing not less than 810 gm, 15 mm
nominal bore.
15mm nominal bore, 165mm long.
18.32.3 Weighing not less than 110 gms.
8.00 EACH 526.00 4,208.00

18.3 Brass stop Providing and fixing brass stop cock of


82
cock approved quality :
18.30.1 15 mm dia 15 mm nominal bore 8.00 EACH 318.00 2,544.00

18.29 Brass bib Providing and fixing brass bib cock of


83
cock approved quality
18.29.1 15 mm dia 15 mm nominal bore 8.00 EACH 306.00 2,448.00

18.48 Providing and fixing PTMT grating of


PTMT
84 approved quality and colour..
grating
18.48.1 Circular type.
18.48.1

18.48.1.1 18.48.1.1 100 mm nominal dia. 4.00 EACH 55.00 220.00

18.48.1.2 125 mm nominal dia with 25 mm waste


18.48.1.2
hole. 4.00 EACH 60.00 240.00
17.68 Providing and fixing mirror of superior
glass (of approved quality)
Mirror (
and of required shape and size with
85 Plasticplastic moulded frame of approved
Frame) make and shape with 6 mm thick hard
board backing :
17.68.2 453x357m Rectangularshape453x357mm
m 4.00 EACH 642.00 2,568.00

17.36 C.I. bend Providing and fixing plain bend of


86
(Plain) required degree.
17.36.1 150 mm 150 mm dia
dia
17.36.1.2 Spun cast iron as per IS – 3989
Spun cast
minimum wall thickness 5 mm 8.00 EACH 825.00 6,600.00

17.55 Lead Providing lead caulked joints to sand


caulked cast iron/ centrifugally cast (spun) iron
86 joints to pipes and fittings of diameter:
C.I. pipes &
fittings
17.55.2 100 mm lOOmm 5.00 EACH 234.00 1,170.00

17.57 Providing and fixing trap of self


cleansing design with screwed
C.I. Trap of
self down or hinged grating with or without
87
cleansingvent arm complete, including cost of
design cutting and making good the walls and
floors :
17.57.1 100X100m 100 mm inlet and 100 mm outlet
m
17.57.1.1 Spun cast iron S & S as per IS: 3989.
Spun cast
3.00 EACH 825.00 2,475.00

17.91 Painting sand cast iron/ centrifugally


Painting cast (spun) iron soil, waste vent pipes
C.I. waste and fittings with two coats of synthetic
vent pipes enamel paint of any colour such as
and fittings chocolate grey, or buff etc. over a coat
88
with of primer (of approved quality) for new
synthetic work :
enamel
paint

17.91.2 100 mm 100 mm diameter pipe


dia 10.00 METER 29.00 290.00

17.35 Providing and fixing bend of required


C.I. Bend degree with access door, insertion
89
(with lid ) rubber washer 3 mm thick, bolts and
nuts complete.
17.35.1 150 mm 150 mm dia
dia
17.35.1.2 Spun cast iron as per IS – 3989
Spun cast minimum wall thickness 5 mm
8.00 EACH 430.00 3,440.00

17.37 Heel rest Providing and ftxing heel rest sanitary


sanitary bend
90
bend of
cast iron
17.37.1 100 mm 100 mm dia
dia
17.37.1.2 Spun cast Spun cast iron as per IS - 3989 2.00 EACH 387.00 774.00

17.41 Providing and fiXing single equal plain


Single
junction of required degree :
equal plain
91
junction of
cast iron
17.41.2 100mm 100x100x100 mm
17.41.2.2 Spun cast Spun cast iron as per IS – 3989 2.00 EACH 607.00 1,214.00

17.52 Providing and fixing door piece, insertion


Fixing door rubber washer 3mm thick, bolts and
92 piece, C.I. nuts complete :
pipe fittings
17.52.1 lOOmm
100mm dia
17.52.1.2 Spun cast Spun cast iron as per IS - 3989 8.00 EACH 547.00 4,376.00

17.53 C.I.terminal Providing and fiXing terminal guard:


93
guard
17.53.2 100 mm lOOmm
17.53.2.2 Spun cast Spun cast iron as per IS - 3989 2.00 EACH 300.00 600.00

94 17.54 C.I. Collar Providing and fiXing collar:


17.54.1 100 mm lOOmm
17.54.1.2 Sand cast iron S & S as per IS - 3989
Spun cast
8.00 EACH 317.00 2,536.00

17.34 Providing and fixing M.S. holder-bat


clamps of approved design to Sand
Cast iron/cast iron (spun) pipe
embedded in and including cement
concrete blocks 10x10x10cm of Cement
95 M.S. holder Concrete 1:2:4 mix (1 cement : 2 sand :
4 graded stone aggregate 20mm
nominal size) including cost of cutting
holes and making good the walls etc. :

17.34.2 For 100 For 100 mm dia. Pipe


mm dia
pipe 5.00 EACH 66.00 330.00

18.6 Providing and fixing Chlorinated


Polyvinyl Chloride (CPVC) pipes, having
thermal stability for hot and cold water
supply including all CPVC plain and
CPVC brass threaded fittings i/c fixing the pipe
pipes with clamps at 1.00 m spacing. This
96 includes jointing of pipes and fittings with
internal
work one step CPVC solvent cement and
testing of joints complete as per
direction of Engineer-in-Charge.

18.6.1 Exposed Internal work - Exposed on wall


on wall 8.00 METER 129.00 1,032.00
18.6.1.1 15 mm 15 mm nominal outer dia .Pipes.
5.00 METER 153.00 765.00
18.6.1.2 20 mm 20 mm nominal outer dia .Pipes.
18.7 Providing and fixing Chlorinated
Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot
and cold water supply including all
CPVC CPVC plain and brass threaded fittings.
pipes This included jointing of pipes and
97
forexternal fittings with one step CPVC solvent
work cement, trenching, refilling and testing of
joints complete as per direction of
Engineer in Charge.
External work

18.7.3 25 mm 25 mm nominal outer dia .Pipes. 10.00 METER 185.00 1,850.00

18.7.4 32mm 32 mm nominal outer dia .Pipes. 5.00 METER 238.00 1,190.00

18.51 Providing and fixing PTMT Ball cock of


approved quality, colour and make
PTMT Ball
98 complete with Epoxy coated aluminium
cock
rod with L.P./ H.P.H.D. plastic ball.

18.51.3 25 mm nominal bore, 152mm long.


25mmdia
Weighing not less than 440 gms. 2.00 EACH 615.00 1,230.00

18.52 Unplasticis Providing and fixing Unplasticised


ed P.V.C. P.V.C. connection pipe with PTMT Nuts
99 collar and bush of approved quality and
connection
pipe colour 15 mm nominal bore
18.52.2 45cm 45 cm length. 2.00 EACH 79.00 158.00
18.57 Cutting Cutting holes upto 15x15 em in R.C.C.
100 holes floors and roofs for passing
R.C.C. 7.00 EACH 129.00 903.00
drain pipe etc. and repairing the hole
16.16 Supplying, filling, spreading and leveling
gravels of size range 5 mm to 10 mm, in
Gravels of the recharge pit, over the existing layer
in the of boulders, in required thickness, for all
101
recharge leads and lifts, all complete as per
pit direction of Engineer-in-charge.
0.68 CUM 877.00 596.36

16.17 Supplying, filling, spreading and leveling


coarse sand of size range 1.5 mm to 2
Coarse mm in recharge pit, in required thickness
sand in over gravel layer, for all leads and lifts,
102
recharge all complete as per direction of Engineer-
pit in-charge.
0.68 CUM 819.00 556.92

Providing and fixing unplasticised Rigid


PVC soil and waste pipes conforming to
IS: 13592 Type B including jointing with
seal ring conforming to IS : 5382 leaving
103 17.58 10 mm gap for thermal expansion.
Single socketed pipes for working
pressure of 4 kg/sqcm.

110 mm diameter (minimum wall


17.58.2 thickness 3.2mm) 40.00 METER 238.00 9,520.00

12.33 Providing and fixing on wall face


Unplasticised - PVC moulded fittings/
accessories for Unplasticised Rigid PVC
Unplasticis rain water pipes conforming to IS :
104 ed - UPVC 13592 Type A including jointing with
fittings seal ring conforming to IS : 5382 leaving
10 mm gap for thermal expansion.

12.33.1 Coupler Coupler


12.33.1.2 110 mm (minimum wall thickness
110 mm
2.2mm) 10.00 EACH 102.00 1,020.00

12.33.6 Shoe Shoe (Plain)


12.33.6.2 110 mm bend (minimum wall thickness
110 mm
2.2mm) 20.00 EACH 99.00 1,980.00

12.33.5 Bend Bend 87.5°


12.33.5.2 110 mm bend (minimum wall thickness
110 mm
2.2mm) 12.00 EACH 112.00 1,344.00

12.34 UPVC pipe Providing and fixing unplasticised -PVC


105 pipe clips of approved design to
clips
unplasticised - PVC rain water pipes by
12.34.2 110 mm (minimum wall thickness
110 mm
2.2mm) 12.00 EACH 114.00 1,368.00
16.2 Providing and fixing of unplasticised rigid
PVC rain water harvesting filter kit
including filter f 160 mm diameter wall
thickness 3.2 mm for PVC valve 110
mm diameter, UV protected conforming
Rain water to IS:13592 with working pressure
harvesting 6kg/sqcm Type B, capacity
filter kit 40kiloliter/hour "Jal Santosh" make or
106
unplasticise equivalent and including all accesories
d (filter dia like unplasticised PVC pipe clips of
160mm) approved design with bombay nail of
required length including making good
the wall etc. complete for catchment
area upto 200 sqm.
1.00 EACH 8679.00 8,679.00

16.22 Borewell Borewell adaptor for connecting rain


107
adaptor water harvesting
16.22.3 160 mm Borewell adaptor pipe
160mmline to borewell.
dia 1.00 EACH 400.00 400.00

16.1 Boring/drilling bore well of required dia


perfectly vertical to receive casing/
strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including
collecting samples from different strata,
Bore well preparing and submitting strata
upto 90 chart/bore log, including hire and
108
meter running charges of all equipments, tools,
depth plants and machineries required for the
job, all complete as per direction of
Engineer –in-charge, upto 90 metre
depth below ground level.

16.1.1 All types of soil upto 90 metre depth.


All types of
soil upto 90
meter
16.1.1.3 200 mm 200 mm dia.
dia 12.00 METER 451.00 5,412.00

16.1.2 Rocky strata including Boulders.Upto 90


Rocky
metre depth.
strata upto
90 meter
16.1.2.3 200 mm 200 mmdia.
dia 47.70 METER 690.00 32,913.00

Supplying, assembling, lowering and


fixing in vertical position in bore well,
unplasticized PVC medium well casing
Unplasticize (CM) pipe of required dia, conforming to
109 16.2 d PVC bore IS: 12818, including required hire and
well casing labour charges, fittings and accessories
etc. all complete, for all depths, as per
direction of Engineer-in-charge.

200 mm nominal dia(minimum wall


16.2.3 200 mm dia
thickness 10mm)
16.2.2.2 200 mm dia. 120.00 METER 559.00 67,080.00

Supplying, assembling, lowering and


fixing in vertical position in
bore well unplasticized PVC medium
Unplasticize well screen (RMS) pipes with ribs,
110 16.3 d PVC bore conforming to IS: 12818, including hire
well screen and labour charges, fittings and
accessories etc. all complete, for all
depths, as per direction of Engineer-in-
charge.
16.3.3 200 mm dia 200 mm nominal size dia. 3.00 METER 878.00 2,634.00
Supplying, assembling, lowering and
fixing in vertical position in
bore well unplasticized PVC medium
well screen (RMS) pipes with ribs,
conforming to IS: 12818, including hire
111 16.4 and labour charges, fittings and
accessories etc. all complete, for all
depths, as per direction ofEngineer-in-
charge.

16.4.3 200 mm nominal size dia. 3.00 METER 1611.00 4,833.00

Gravel packing in tubewell construction


in accordance with IS:
Gravel 4097, including providing gravel fmel
112 16.6 packing in medium/ coarse, in required grading and
tubewell sizes as per actual requirement, all
complete as per direction of Engineer-in-
charge. 30.14 CUM 947.00 28,542.58

Providing and fixing Bail plug/ Bottom


Bail plug plug of required dia to the bottom of pipe
113 16.1 /Bottom assembly oftubewell as per IS:2800
plug (part 1).

16.10.3 200 mm dia 200 mm dia 2.00 EACH 265.00 530.00

Providing and fixing factory made


precast RCC perforated
drain covers, having concrete of
strength not less than M-25, of size
1000 x 450x50 mm, reinforced with 8
Precast mrn dia four no longitudinal and 9 nos
R.C.C. cross sectional T.M.T. hoop bars,
114 16.18
perforated including providing 50 mrn dia
drain covers perforations @>0 to 125 mrn c/c,
including providing edge binding with
M.S. flats of size 50 mmx1.6 mm
complete, all as per direction of
Engineer-in- charge.
2.00 EACH 959.00 1,918.00

Q1 = SUB TOTAL CIVIL WORKS ( SOR ITEMS ) 57,82,296.17


CIVIL WORKS NON-SOR ITEMS ( Q2 )
n1+1 Project Cost Center No. (PCC No.)
n1+2
n1+3
n1+n=n2
Q2 = SUB TOTAL CIVIL WORKS ( NON SOR ITEMS ) 0.00
Q1+Q2 = TOTAL CIVIL WORKS (SOR + NON SOR ) 57,82,296.00

BOQ

INTERNAL ELECTRIFICATION OF PROPOSED 5 CLASS ROOM AT TEHSIL LEVEL P.G. COLLEGE BALAGHAT (M.P)

Item No/ Sub


Sr. No. I.No.
Item Name Description of Item Qty Unit Rate Amount

4.1 Point wiring Point wiring (excluding metallic switch box & sheet but including
1 concealed rigid switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm.
P.V.C. conduit PVC insulated cable FRLS with copper multi strand conductor ISI
marked in concealed rigid P.V.C. conduit (HMS) ISI marked
4.1.1 Light/fan points Light point/fan points.
primary
4.1.1.1 Short Primary short point 8 Each 305 2440
4.1.1.2 Medium Primary medium point 24 Each 532 12768
4.1.1.3 Long Primary long point 62 Each 816 50592

4.1.2 Looping point (Light point/fan points) looping point


2 secondary
4.1.2.1 Short Secondary short point 5 Each 153 765
4.1.2.2 Medium Secondary medium point 5 Each 266 1330
4.1.2.3 Long Secondary long point 5 Each 408 2040
4.1.3 Socket 6A sep. 3 Pin 6 Amp socket outlet on separate board
3 board
4.1.3.1 Short Short point 1 Each 412 412
4.1.3.2 Medium Medium point 1 Each 662 662
4.1.3.3 Long Long point 3 Each 979 2937

4 4.1.5 Twin control point Twin control light points


4.1.5.3 Long Long point 4 Each 920 3680

4.2 Socket same board Point wiring (excluding metallic switch box & sheet but including
6A switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq.
mm. PVC insulated cable FRLS with copper multi strand conductor
5 ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of 12 Each 170 2040
suitable size and 1.5sq. mm. PVC insulated copper earth continuity
conductor of green colour inside conduit with required materials as
per specification on same board.

4.3 Circuit wiring Wiring for circuit wiring with PVC insulated cable FRLS with
2.5Sq. mm copper multi strand conductor ISI marked in concealed rigid P.V.C.
6 conduit (HMS) of ISI marked suitable size etc. as required as per
specification
4.3.1 2 Wire 2x2.5 Sq.mm. 210 P/mtr 83 17430
4.3.2 4 Wire 4x2.5 Sq.mm. 60 P/mtr 127 7620
4.3.3 6 Wire 6x2.5 Sq.mm. 40 P/mtr 167 6680

9.1 Power point wiring Point wiring (excluding metallic switch box & sheet) for 3 Pin 16
concealed rigid Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS
P.V.C. conduit with copper multi strand conductor ISI marked in concealed rigid
P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16
7 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI
marked and 4sq. mm. PVC insulated FRLS copper earth continuity
conductor of green colour inside conduit, screwless connector for
joints as per specification for :-Using modular accessories

9.1.1 Power point On separate board


9.1.1.3 Long Long point 1 Each 1678 1678
9.1.1.5 Ex. long-II Extra long-II 1 Each 2955 2955

9.2 Same board Same board switch & socket 16 Amp./S.S. combined 20/16/6 Amp
8 1 Each 342 342

16.1 Concealed PVC Supply and fixing PVC conduit ISI marked FRLS along with the
9 conduit HMS accessories in concealed system etc. as required
16.1.1 20 mm. HMS PVC. conduit 20 mm (HMS) 10 Metre 33 330
16.1.2 25 mm. HMS PVC. conduit 25 mm (HMS) 10 Metre 39 390

18.2 Modular G.I. metal Supplying and fixing of approved make modular type G.I. metal box
box (concealed) 1.2mm minimum thick and depth 50mm for single row boxes and
10 60mm depth for two/three row boxes earth terminal stud with nut
and washer with modular base and cover plate including fixing in
concealed etc. as required for:-
18.2.1 G.I box 1 Or 2 1Or 2 Module metal box 2
Each 92 184
module
18.2.2 G.I box 3 module 3 Module metal box 8 Each 115 920
18.2.4 G.I box 6 module 6 Module metal box 2

Each 173 346

18.2.5 G.I box 8/9 module 8/9 Module metal box 2


Each 218 436
18.2.6 G.I box 12 module 12 Module metal box 10 Each 274 2740
18.2.8 G.I box 18 module 18 Module metal box 12 Each 316 3792

19.1 Single core PVC Supplying and drawing single core PVC insulated cable FRLS with
insulated FRLS copper multi strand conductor ISI marked in existing rigid PVC
11 cable casing and capping/conduit in surface or concealed as per
specification.
19.1.1 1.5 sq. mm. 1.5 sq. mm. wire

19.1.1.1 1 wire 1 X 1.5 sq. mm. 60 Metre 12 720


19.1.1.2 2 wire 2 X 1.5 sq. mm. 20 Metre 23 460
19.1.1.3 3 wire 3 X 1.5 sq. mm. 20 Metre 34 680

19.1.2 2.5 sq. mm. 2.5 sq. mm. wire


19.1.2.1 1 wire 1 X 2.5 sq. mm. 310 Metre 18 5580

23.1 Sub mains in Wiring for sub-mains with PVC insulated cable FRLS with copper
recessed/concealed multi strand conductor ISI marked in recessed/concealed rigid PVC
rigid PVC conduit conduit (HMS) FRLS ISI marked of suitable size (conduit included)
12 (HMS) including 2mm thick accessories, connection etc, as required as per
specification. (Refer General Notes for Classification of Conduit
Wiring Point No.11)
23.1.2 3 Wire 3 Wire sub main
23.1.2.3 6.0 sq. mm. cable 6.0 sq. mm. cable 20 Metre 186.00 3720.00

23.1.4 4 Wire 4 Wire sub main


23.1.4.3 6.0 sq. mm. cable 6.0 sq. mm. cable 20 Metre 226 4520

25.16 Porcelain Supply & fixing of I.S.I. marked porcelain rewireable fuse unit of
13 rewireable fuse unit approved make or conforming to I.S. 2086-1982
25.16.3 32A/415 Volts 32Amp/415 Volts 3 Each 108.00 324.00

27.8 MCB 'C' Series, Supply of ISI marked and accepted standard of miniature circuit
240/415V, 50 breaker (MCB) of 'C' series with short circuit indication, suitable for
14 Cycle, 10kA/15kA 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming
to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without
enclosures :-
27.8.1 Single pole Single pole
27.8.1.2 MCB SP 6A to MCB SP 6Amp to 32Amp 10kA rating
32A, 10kA 22 Each 136 2992

27.8.2 Double Pole Double pole


27.8.2.2 MCB DP 6A to MCB DP 6Amp to 32Amp 10kA rating
32A, 10kA 2 Each 425.00 850.00

27.8.3 Triple pole For Triple pole


27.8.3.3 MCB TP 40A,
MCB TP For 40Amp 10kA rating 1 Each 1036 1036
10kA
27.8.3.4 MCB TP 50A to MCB TP 50Amp to 63Amp 10kA rating
1 Each 1018.00 1018.00
63A, 10kA

27.8.4 Four pole Four pole


27.8.4.2 MCB FP 6A to MCB FP 6Amp to 32Amp 10kA rating
1 Each 938 938
32A, 10kA
27.8.4.4 MCB FP 50A to MCB FP 50Amp to 63 Amp 10kA rating
1 Each 1348 1348
63A, 10kA

27.11 SPN MCB DB Supply of approved make powder coated sheet steel encloser SPN
MCB DB inclusive of busbar, neutral bar, earth bar, connection
15 copper wire not less than 16 sq.mm & two earth terminals etc.
complete as per IS:13032(exclusive of MCB & isolator)-

27.11.6 12 Way double 12 Way double door IP 43 protection


door 1 Each 1262.00 1262.00

27.12 TPN MCB DB Supplying of approved make TPN MCB DB metal double door IP
double door 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO
as incomer and SP MCBs as outgoing inclusive of busbar, neutral
16 bar, earth bar, connection copper wire not less than 16 sq.mm & two
earth terminals etc. complete as per IS:13032(exclusive of MCB &
isolator):
27.12.2 4 Way (8+12) 4 Way (8+12) 1 Each 2017.00 2017.00

27.23 Steel enclosure, Supply & fixing of approved make accepted standard sheet steel
neutral bar enclosure (dust protected) duly powder coated paint neutral bar
17 suitable for suitable for MCB/RCBOs/MCCB of capacity as required etc.
MCB/RCBOs/M complete as per specification (exclusive of M.C.B./
CCB MCCB/RCBOs)
27.23.1 For MCB For MCB
27.23.1.2 DP/TP/FP DP/TP/FP enclosure
enclosure 1 Each 244.00 244.00

28.4 Fixing of Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required


MCB/MCCB/Isol as per accepted practice, including mounting on busbar and cable
18 ator, (labour only) connection etc. complete (labour only)

28.4.1 MCB/Isolator MCB/Isolator SP/DP


24 Each 8 192
SP/DP
28.4.2 MCB/MCCB MCB/MCCB Isolator TP/TPN/FP
Isolator TP/TPN/FP 4 Each 12 48

28.8 Labour charges Labour charges for fixing sheet steel enclosures, MCB/MCCBDB
flush mounting type, as per accepted practice, duly embedded and
19 end plate completely flushed in wall, cable connection etc. complete
:-
For item For item no :-
28.8.1 Item SOR no. 27.11.1 to 27.11.7 ; 27.12.1 to 27.12.3 & 27.13.1 2 Each 162 324

20 29.7 LED lamp Supply and fixing in position LED lamp of approved make
29.7.5 9W 250Volt 9 Watt250Volt 12 Each 100 1200

29.25 Modular Supply and fixing of approved make step type modular electronic fan
21 electronic fan regulator including connection etc. as required on existing board
regulator
29.25.2 2 Module 100 Watt(2 module) 30 Each 390 11700

30.1 Electric ceiling fan Supplying, erection and testing of approved make electric Ceiling
fan of double ball bearing complete with standard down rod, canopy,
hanging shackle, Aluminium blades, without regulator, A.C. 230-
22 250 volts including connections with all necessary material complete
of approved as required confirming to IS :374/2019 with upto date
amendments.
30.1.2 1200 mm sweep Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air
30 Each 1668 50040
delivery 210 m³/min and service value ≥ 4.00 as per BEE..

30.4 Fresh air fan Supplying, erection and testing of approved make 'Fresh air fan' AC
23 230-250 volts with connection and including frame bolt/anchor hole
fasteners etc. complete finished and as required.
30.4.3 300 mm 300 mm sweep bush type 4 Each 1113 4452

31.3 LED tube rod Supply and fixing Led tube rod comprising of LED tube with non-
fixture integral/integral driver, upto 6500K color temp having 40000
burning hrs life with minimum @ L 70, system lumen output should
be minimum with system efficacy> 100 lm/Watt. LED driver PF>
24 0.95 & THD < 20%. The colour rendering index of LED light
should be more than 70. Submission LM 79-08/IS16106 (2012),
IEC60598, IEC61347i/c connection wire, testing etc. to complete
the job.
Tube light LED 1 Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body,
31.3.4 43 Each 782 33626
X 20/22W PC diffuser.
31.9 Street light with Supply and fixing street light with high power LED of 3 to 6 W each
high power LED on existing bracket assembled on single MCPCB, system lumens
system output with efficacy>120 lm/W. luminiare having color temp upto
6500K & 50000 burning hrs. life with minimum @ L 70, The
colour rendering index of LED light should be more than 70.
Luminiare comprises of driver, PF> 0.95 & surge protection 10KV.
Housing made of pressure die cast aluminium with heat resistant flat
glass/Lens type, IP65 protection. Submission LM 79-08/IS16106
(2012), IEC60598, IEC61347i/c connection wire, testing etc. to
25 complete the job.
31.9.2 24-25W 24Watt to 25Watt, color temp 3000-6500k as required. 4 Each 2737.00 10948.00

32.3 Fixing for ceiling Providing and fixing circular/hexagonal cast iron or M.S. sheet box
fan clamp for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of
1.5mm thick M.S. sheet with its top surface hacked for proper
26 bonding, top lid shall be screwed into the cast iron/M.S. sheet box by 30 Each 69 2070
mean of 3.3mm dia. round headed screws, one lock at the corners.
Clamp shall be made of 12mm dia M.S. bar bent to shape as per
standard drawing.

35.14 Civil work for Providing recess in brick wall suitable for erecting of exhaust fan up
27 exhaust fan to 450 sweep complete with grouting of nut bolts, plastering and
colour wash to match the colour of wall.
35.14.1 Upto 9" For wall thickness upto 9" 4 Each 404 1616

37.3 Earthing with G.I. Earthing with G.I. earth plate 600mm X 600mm X 6mm thick
earth plate including accessories and providing masonry encloser in
28 600x600x6 mm cement mortar, cover plate having locking arrangement on the top 1 Each 3169 3169
and G.I. watering pipe 20mm dia 2.7 metre long etc. (but without
charcoal or coke and salt) complete as required

37.5 Add extra for using Add extra for using salt and charcoal/coke for G.I. plate or copper
salt and charcoal/ plate earth electrode as required including excavation and refilling
29 coke for G.I /copper the pit in all type of soil, murrum 1 Each 1015 1015
plate (murrum)

37.12 25x5 G.I. strip Providing and fixing 25mm X 5mm G.I. strip in 40 mm dia G.I. pipe
30 from earth electrode as required
10 Metre 401 4010

37.17 6 SWG dia G.I. Providing and fixing 4.0mm (8 SWG) dia G.I. wire on surface or in
31 wire on recessed for loop earthing as required 20 Metre 14 280
surface/recessed

37.39 PVC insulated cu. Supply and drawing PVC insulated copper cable (earth continuity
cable earth conductor) of green colour FRLS with copper multi strand
32 continuity conductor ISI mark in existing conduit along with other wires as
conductor required as per specification :
37.39.2 6 sq. mm. 6 sq. mm. 20 Metre 47 940

41.1 XLPE insulated Supply of XLPE insulated power cable (conforming IS-7098 Part-I)
33 power cable, al. 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu.
conductor stranded /solid conductor
41.1.10 4 core armoured 4 core armoured
41.1.10.2 10 sq. mm. 10 sq. mm. 80 Metre 104.00 8320.00

34 41.5 Gland Brass compression gland


41.5.1.2 22 mm Gland size 22mm suitable for cable 2/3, 3½, 2/4 x 10 sq. mm or 2x
2 Each 32.00 64.00
16 sq. mm

41.7 Crimping type Supplying and fixing crimping type alum. lugs as per I.S.S.
alum. lugs specification suitable for following size of cable with alu./copper
35 solid/stranded conductor evenly crimped with high/pressure tool and
connected to switch gear/bus/M.C.C.B./M.C.B. etc. as required
complete.
For conductor size- For conductor size-
41.7.1 6 -16 sq. mm 6mm to 16 sq. mm 8 Each 2 16

41.8 Pin terminal lugs Supplying & fixing pin terminal lugs as per ISS specification suitable
36 for cable evenly cramped with high pressure tool & connection to
switch gear terminal as required complete.
41.8.2 Copper lugs pin Copper lugs pin type
type
41.8.2.1 Upto 16 sq. mm Upto 16 sq. mm conductor size
22 Each 16 352
conductor

41.12 G.I. pipe for Supplying & installing G.I. pipe for protection of underground cable
protection of fixed on wall/support/in trench/fixed between two rigid existing
underground support of wall/beam for erection of ceiling Fan/down rod for stiff
cable pendent for light luminaries /fan/protective for earthing, lightening
conductor down strip/overhead service line/for submersible cable or
37 centrifugal pump for water supply with necessary iron clamp
coupler, bend, tee, elbow, nuts and bolts etc. complete in an
approved manner as required to complete excluding cost of
excavation/dismantling & other finished masonry Item complete.

41.12.1.6 50.00mm 50.00mm 5 Metre 463 2315

41.49 Laying, 1.1KV Laying of one number armoured/unarmoured cable 1.1KV grade of
grade of size not size not exceeding 25 sq. mm on wall/truss with approved type of
38 exceeding 25 sq. iron clamp etc. as required.
50 Metre 18 900
mm

41.52 Laying of Laying of underground cable armoured./unarmoured as per


underground cable specification in air suspended on existing approved type of iron
39 clamp, G.I wire 7/1.6mm & shackle insulator/insulated strip
complete.
41.52.1 16 sq. mm. 1/2/3/4 Core cable upto 16 sq. mm 30 Metre 17 510
42.76 Fire Supplying & fixing of fire extinguisher/refills as per IS specification
40 extinguisher/refills

42.76.1 Duly refilled 6 Kg ABC type duly refilled 6 Kg & ready to use 2 Each 3200 6400
TOTAL SOR ITEM 291325