Professional Documents
Culture Documents
AFTER ANALYSIS RECOMMENDATION: at Present M/C Is Running in Ok Condition
AFTER ANALYSIS RECOMMENDATION: at Present M/C Is Running in Ok Condition
Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
LHS 1.5 0.4 2.0
RHS 2.5 0.8 1.2
AFTER ANALYSIS RECOMMENDATION: At present m/c is running in ok condition.
REPORT FORMAT
Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
RHS 1.8 2.3 5.5
LHS 2.1 2.2 1.5
AFTER ANALYSIS RECOMMENDATION: Some extra vibration rest on RHS bearing due to much
axial clearance but in normal condition.
Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
LHS 2.66 2.9 2.5
RHS 1.5 1.3 1.4
AFTER ANALYSIS RECOMMENDATION: At present m/c is running in normal condition.
REPORT FORMAT
Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 12.5 3.5 6.6 2.5 10.7 3.5
NDE 5.5 2.6 7.0 3.5 6.5 2.2
AFTER ANALYSIS RECOMMENDATION: After adding wt. of 4 kg. Balancing was performed,
Some extra vibration rest on both bearing due to much clearance but in normal condition.
Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 1.2 0.7 2.8
NDE 1.2 1.3 1.6
AFTER ANALYSIS RECOMMENDATION: At present m/c is running in normal condition.
REPORT FORMAT
Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 5.0 7.8 3.4
NDE 6.2 7.5 3.7
AFTER ANALYSIS RECOMMENDATION: Extra vibration rest on both bearing due to much
clearance & lack of polish.
Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 2.3 1.7 3.5
NDE 2.6 2.9 2.5
AFTER ANALYSIS RECOMMENDATION: At present m/c is running in normal condition.