REPORT FORMAT

Name of Site: Reliance sugar mill (Nepal) Date: 24/01/2021

Machine Name: Fibrizer(without load) H=Horizontal

Motor R.P.M. : V=Vertical

Rotor R.P.M. : 625 A=Axial

Permissible Limit: 11.0 mm/sec All readings in mm/sec

Analyzer Used Baseline 6050

Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 9.5 3.2 4.1
NDE 6.3 3.2 3.6
AFTER ANALYSIS RECOMMENDATION: Some extra vibration rest on DE bearing due to
misalignment & looseness of sleeve.

REPORT FORMAT

Name of Site: Reliance sugar mill (Nepal) Date: 24/01/2021

Machine Name: Fibrizer(with load) H=Horizontal

Motor R.P.M. : V=Vertical

Rotor R.P.M. : 625 A=Axial

Permissible Limit: 11.0 mm/sec All readings in mm/sec

Analyzer Used Baseline 6050

Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 6.6 3.2 3.1
NDE 4.6 3.2 2.3
AFTER ANALYSIS RECOMMENDATION: Some extra vibration rest on DE bearing due to
misalignment & looseness of sleeve.

Constant Dynamic Balancing Services, 3/281, Sector-H, Jankipuram, Lucknow-226021


costantdynamic@yahoo.co.in
Mob.09451894811, 9453409475, 8765766258
REPORT FORMAT

Name of Site: Reliance sugar mill (Nepal) Date: 24/01/2021

Machine Name: Beggase Blower # 2 H=Horizontal

Motor R.P.M. : V=Vertical

Rotor R.P.M. : A=Axial

Permissible Limit: 7.1 mm/sec All readings in mm/sec

Analyzer Used Baseline 6050

Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 5.3 5.2 6.8
NDE 4.6 4.3 6.0
AFTER ANALYSIS RECOMMENDATION: Some extra vibration rest on both bearing due to much
clearance & lake of polish.

REPORT FORMAT

Name of Site: Reliance sugar mill (Nepal) Date: 24/01/2021

Machine Name: ID FAN # 1 H=Horizontal

Motor R.P.M. : V=Vertical

Rotor R.P.M. : A=Axial

Permissible Limit: 7.1 mm/sec All readings in mm/sec

Analyzer Used Baseline 6050

Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 2.2 1.2 1.2
NDE 1.7 1.3 1.5
AFTER ANALYSIS RECOMMENDATION: At present m/c running in ok condition.

Constant Dynamic Balancing Services, 3/281, Sector-H, Jankipuram, Lucknow-226021


costantdynamic@yahoo.co.in
Mob.09451894811, 9453409475, 8765766258
REPORT FORMAT

Name of Site: Reliance sugar mill (Nepal) Date: 24/01/2021

Machine Name: ID FAN # 2 H=Horizontal

Motor R.P.M. : V=Vertical

Rotor R.P.M. : A=Axial

Permissible Limit: 7.1 mm/sec All readings in mm/sec

Analyzer Used Baseline 6050

Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 2.7 3.6 2.4
NDE 5.6 6.8 5.4
AFTER ANALYSIS RECOMMENDATION: Some extra vibration rest on NDE bearing due to much
clearance & lake of polish.

REPORT FORMAT

Name of Site: Reliance sugar mill (Nepal) Date: 24/01/2021

Machine Name: ID FAN # 3 H=Horizontal

Motor R.P.M. : V=Vertical

Rotor R.P.M. : A=Axial

Permissible Limit: 7.1 mm/sec All readings in mm/sec

Analyzer Used Baseline 6050

Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 1.3 1.2 1.3
NDE 1.3 1.1 1.0
AFTER ANALYSIS RECOMMENDATION: At present m/c running in good condition.

Constant Dynamic Balancing Services, 3/281, Sector-H, Jankipuram, Lucknow-226021


costantdynamic@yahoo.co.in
Mob.09451894811, 9453409475, 8765766258
REPORT FORMAT

Name of Site: Reliance sugar mill (Nepal) Date: 24/01/2021

Machine Name: FD FAN # 1 H=Horizontal

Motor R.P.M. : V=Vertical

Rotor R.P.M. : A=Axial

Permissible Limit: 7.1 mm/sec All readings in mm/sec

Analyzer Used Baseline 6050

Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 1.6 1.1 1.3
NDE 2.8 2.1 2.0
AFTER ANALYSIS RECOMMENDATION: At present m/c running in normal condition.

REPORT FORMAT

Name of Site: Reliance sugar mill (Nepal) Date: 24/01/2021

Machine Name: FD FAN # 2 H=Horizontal

Motor R.P.M. : V=Vertical

Rotor R.P.M. : A=Axial

Permissible Limit: 7.1 mm/sec All readings in mm/sec

Analyzer Used Baseline 6050

Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 4.5 5.2 2.2
NDE 5.9 5.6 6.1
AFTER ANALYSIS RECOMMENDATION: Some extra vibration rest on both bearing due to much
clearance & lake of polish.

Constant Dynamic Balancing Services, 3/281, Sector-H, Jankipuram, Lucknow-226021


costantdynamic@yahoo.co.in
Mob.09451894811, 9453409475, 8765766258
REPORT FORMAT

Name of Site: Reliance sugar mill (Nepal) Date: 24/01/2021

Machine Name: SA FAN # 2 H=Horizontal

Motor R.P.M. : V=Vertical

Rotor R.P.M. : A=Axial

Permissible Limit: 7.1 mm/sec All readings in mm/sec

Analyzer Used Baseline 6050

Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 3.2 2.6 2.6
NDE 2.8 2.8 3.1
AFTER ANALYSIS RECOMMENDATION: At present m/c running in normal condition.

REPORT FORMAT

Name of Site: Reliance sugar mill (Nepal) Date: 24/01/2021

Machine Name: SA FAN # 1 H=Horizontal

Motor R.P.M. : V=Vertical

Rotor R.P.M. : A=Axial

Permissible Limit: 7.1 mm/sec All readings in mm/sec

Analyzer Used Baseline 6050

Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 4.4 3.3 6.6
NDE 5.6 3.7 4.0
AFTER ANALYSIS RECOMMENDATION: Some extra vibration rest on both bearing due to much
clearance & lake of polish.

Constant Dynamic Balancing Services, 3/281, Sector-H, Jankipuram, Lucknow-226021


costantdynamic@yahoo.co.in
Mob.09451894811, 9453409475, 8765766258
REPORT FORMAT

Name of Site: Reliance sugar mill (Nepal) Date: 24/01/2021

Machine Name: S T Cutter H=Horizontal

Motor R.P.M. : V=Vertical

Rotor R.P.M. : A=Axial

Permissible Limit: 11.0 mm/sec All readings in mm/sec

Analyzer Used Baseline 6050

Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 2.5 2.5 3.4
NDE 3.8 3.3 6.8
AFTER ANALYSIS RECOMMENDATION: Some extra vibration rest on LHS bearing due to much
clearance but m/c running in under limit condition.

REPORT FORMAT

Name of Site: Reliance sugar mill (Nepal) Date: 24/01/2021

Machine Name: Cutter H=Horizontal

Motor R.P.M. : V=Vertical

Rotor R.P.M. : A=Axial

Permissible Limit: 7.1 mm/sec All readings in mm/sec

Analyzer Used Baseline 6050

Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 6.5 5.3 10.2
NDE 4.5 6.0 8.3
AFTER ANALYSIS RECOMMENDATION: Some extra vibration rest on both bearing due to much
clearance & lake of polish.

Constant Dynamic Balancing Services, 3/281, Sector-H, Jankipuram, Lucknow-226021


costantdynamic@yahoo.co.in
Mob.09451894811, 9453409475, 8765766258
REPORT FORMAT

Name of Site: Reliance sugar mill (Nepal) Date: 24/01/2021

Machine Name: Chopper H=Horizontal

Motor R.P.M. : V=Vertical

Rotor R.P.M. : A=Axial

Permissible Limit: 7.1 mm/sec All readings in mm/sec

Analyzer Used Baseline 6050

Vibration Level H V A
Bearing No. Initial Final Initial Final Initial Final
DE 2.6 2.6 4.5
NDE 2.4 2.6 3.2
AFTER ANALYSIS RECOMMENDATION: At present m/c running in normal condition.

Constant Dynamic Balancing Services, 3/281, Sector-H, Jankipuram, Lucknow-226021


costantdynamic@yahoo.co.in
Mob.09451894811, 9453409475, 8765766258

You might also like