Mypin: Ordering Code Dimension and Mounting
Mypin: Ordering Code Dimension and Mounting
<<
<<
5 FH9 W96* H96* L80mm
10 160W*80H*70L
Warning 90-260V AC/DC
mounting W92* H92mm
<<
length/meter
<<
SET <</Rst
<<
<<
* To avoid using this instrument in environment to modify data,press SET key to confirm ,then LED
N none
full of dust / caustic gas / strong vibration/ overflow OUT1 Stop to flash
FH8 8digit counter orlength R R:relay F:buzz
water or explosive oil. F:BuZZ
PV window display :count data / parameter code S triode/SSR Modify decimal point: when LED flashing,
Application ② SV window display : preset value / parameter value I I:4-20mA V:0-10V keeping hold SET key, and press key once,
<<
1 Can be used as counter / lenght, counting meter / yard /angle / position, * SET Select or Confirm key preset N none the decimal point will change once ,then loose key in
total count or batch count or current count * < < / R s t shift key / reset key output OUT2 R R:relay F:buzz required position
2 input: contact / proximity photoelectric switches / encoder,
S triode/SSR
sine wave / Square wave / triangle wave etc voltage pulses *
<<
>>
/Rst
>>
SET
Weight < 350g AC/DC.OUT1:relay OUT2:relay,communication:RS85,
FH4 4 digit counter or length input:encoder 100pulse/Rpm,DC12V
1
Press SET key until to enter manu,then loose COM RXD TXD RS232
↓SET control output application
→
key,refer parameters setting steps to modify data
communication baud rate , 19 18 17
0: 9.6 KBi t / s 1:19.2K bit / S, 1 R control output: RS485
preset value 1(SV1) > preset value 2(SV2) INA INB 0V Vcc+24V/12V A+ B- 18-30VAC/DC
↓ SET Pc= vaule / Per Pulse ,range:0.0001-999999,
↓SET factory 0: 9.6 K Bit / s
→
→
→
→
PV : counting or length value
→
PV display data=∑Pc*Pulse, 12 11 10 9 8 7 6 5 4 3 2 1
OUT1: if PV data >= SV1,OUT1 active,stop to count,after Delay time
E.g Pc=10 PCS / Per pulse, Pc=0.01m / per communication ID address :
TIM1,reset PV data=0, reset OUT1 and OUT2 at the same
pulse ,Pc=1cm/per pulse, the count unit is 000-255,factory=001 RST NC NO 90-260V AC/DC
time(OUT1 ,OUT2 =OFF) OUT2 OUT1
↓SET determined by Pc parameter ↓ SET
Parameter lock, range : 0-255
OUT2: if PV data >= SV2, OUT2 active, but continune to count, FH6/FH8/ FH9
after Delay time TIM2, reset OUT2 (OUT2=OFF)
preset point 1 : output control, LCK=000 open lock, can be read and write
can be select R C F N H L , 2 C control output(only for SV1) INA
LCK=010, lock, only read , cant write or modify
→1 + 7
refer to application OUT1: if PV data >= SV1, OUT1 active and reset PV data=0 18-30V DC/AC
↓SET ↓ immediately, continue to count from 0, after Delay time TIM1, OR 90-260V AC/DC
→2 - 8 INB
preset point 1: output delay time ( for press SET to Return PC parameter or quit menu reset OUT1 and OUT2 at the same time(OUT1,OUT2=OFF) 9 0V
3
only OUT1=R or C ) 3 F control output: totalize count NO
10
OUT1
OUT1: if PV data >= SV1, OUT1 active, continune to count, OUT1 4
RST
↓SET range: 0.01-99.99 seconds
Input application keeping active until manual reset NC 5 11 VCC+24V/12V
preset point 2 setting (shield when unused) OUT2
OUT2: if PV data >= SV2, OUT2 active, continune to count, OUT2
range:.0001-999999
contact input: should be connected capacitor to prevent contact 6 12
keeping active until reset by OUT1 R C control or manual
required data: preset point 2 <= preset point 1 jitter, capacity: 0.1-10uf, suggest capacitor : 4.7uf
reset, NOTICE :required SV2 < SV1
↓SET preset point 2 :output control,
1 A input application( Contact ,switch,encoder,voltage pulse) 4 N control output: one cycle output(only for OUT1)
FH4 Series
INA :increase count ,connect between INA and 0V OUT1: if PV data >= SV1, OUT1 active, stop to count, OUT1 keeping
OUTA
can be select R F H L OUT INA INA INA
( No C N) refer to application INB : allow or forbid count, INA increase count when INB active until manual reset C
contact
OUTB
5H High alarm control output INB encoder INB
↓SET open or Low Level(<1V) , INA forbid or dont count when INB
OUT1: if PV data >= SV1, OUT1 active, continune to count,
switch
0V
INB
0V 0V
0V
0V
preset point :output delay time( for only connect High level( H > 5V) +V
if PV data < SV1, OUT1 Inactive,continune to count ,OUT1 +V Vcc Vcc Vcc
OUT2=R ) range: 0.01-99.99 seconds can be reset by manual
Capacity 0.1-10uF Connect to encoder
input select:
↓ SET
A / B : one input, contact / switches / pulse
2 B input application:( Contact ,switch,encoder, voltage pulse) OUT2: if PV data >= SV2, OUT2 active,continune to count,
if PV data < SV2, OUT2 Inactive,continune to count,OUT2
Connect to switch
Connect to contact or wheel
INA: increase or decrease count, connect between INA
C : two inputs: contact / switches / pulse can be RESET by OUT1 R /C control output or manual reset
and 0V
6 L LOW alarm control output
Factory Products Contains
D encoder / wheel / 90 degree phase pulse
INB: used to control INA, INA increase count when INB
↓SET PV window count data decimal point: OPEN or low Level( <1V), INA decrease count when INB
OUT1: if PV data < SV1, OUT1 active, continune to count,
if PV data >= SV1, OUT1 Inactive,continune to count ,OUT1
★ 1 Copy of user manual
★ 1 Inspection certificate
int: 000000 1 decimal point : 00000.0 can be reset by manual ★ 2 installing brackets.
connect High level (>5V)
2 decimal point :0000.00 3 decimal point: We are responsible for the overal repairment for the failure of manufactorying
OUT2: if PV data < SV2, OUT2 active,continune to count,
000.000 4 decimal point 00.0000 quality within 12 months since the date of purchase.
if PV data >= SV2, OUT2 Inactive,continune to count,OUT2
↓SET counting speed,
3 C input application ( Contact ,switch,encoder,voltage pulse),
can be RESET by OUT1 R /C control output or manual reset
Repair fee will be charged accordingly for demage caused by improper
use.。
PV data=INA-INB
contact input:CPS=0020, switch input Terminal connection(refer to the lable on meter)
INA :increase count,connect between INA and 0V Modbus protocol or other information
CPS=1000, encoder input:CPS=5000
INB: decrease count,connect between INB and 0V PLS Download from :www.mypinchina.com
↓ SET
power down saving
18-30V DC/AC →1 + 10 INA
IP/wechat: 86-18689341985
YES: saving data , start to count from power
down data when power on 4D input: encoder or 90 degree phase pulse or90-260V AC/DC
→2 - 11 INB Email:sale@mypinchina.com
NO: no saving, start to count from 0
Reversible UP and Down counting with direction 3 12 0V
RST
Main Products
↓SET when power on
INA :A phase increase count, connect between INA and 0V
NO
13
OUT1
RS232
preset batch (only for batch counter / length) 7 A+ 16 RXD Power meter
RS485