Download as pdf or txt
Download as pdf or txt
You are on page 1of 27

(In Conventional Locos)

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

 Contactor is a device, used to close or open the


HT Circuit.

 All Contactors are operated remotely from


Driver’s desk.

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

 It is dangerous to operate High Tension circuit by


human being.

 These Contactors are operated from Driver’s desk,


remotely.

 When these contactors are operated, HT circuits will


close or open as per requirement.
Phase II - Module No. STC-TRS-Conv.-02
CAMTECH, Gwalior

It consists of low voltage circuit with a switch.

When switch is closed Electro Magnet will energise and will


close the contactor in case of EMC and in case EP contactor, it
will allow air pressure to operate contactor.

In single phase contactor only one set of fixed and movable


contacts are provided.

In three phase contactor three sets of fixed and movable


contacts and all of them are operated simultaneously to
open/close the circuit.
Phase II - Module No. STC-TRS-Conv.-02
CAMTECH, Gwalior

1. 3.

2.

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

(Electro Magnetic)

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

 C 101 – MCP1
 C 106 – MVMT2
 C 102 – MCP2
 C 107 – MVR
 C 103 – MCP3
 C 118 – ARNO
 C 105 – MVMT1

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

1. Battery 9. Return spring


2. Fuse 10. Actuating rod
3. Switch 11. Fixed Jaw
4. Electro magnet 12. Arc-chute
5. Connecting 13. Blow out coil
wires
14. Motor
6. Axis
15. ARNO
7. Armature
16. Flexible shunt
8. Insulator
17. Mobile Jaw

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

C118 Other EM Contactors


Phase II - Module No. STC-TRS-Conv.-02
CAMTECH, Gwalior

Contactor Purpose
C101 (Three Phase) For MCP-1
C102 (Three Phase) For MCP-2
C103 (Three Phase) For MCP-3
C105 (Three Phase) For MVMT-1
C106 (Three Phase) For MVMT-2
C107 (Three Phase) For MVRH
C118 (Single Phase) For giving starting phase to ARNO

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

EM Contactors For Starting Auxiliaries

From ARNO

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

(Electro Pneumatic)

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

1. Battery 11. Axis


2. Fuse 12. Actuating rod
3. Switch 13. Insulator
4. Connecting wires 14. Fixed Jaw
5. Electromagnet 15. Mobile Jaw
6. Armature 16. Flexible shunt
7. Control Reservoir 17. Source of Supply
8. Exhaust port 18. Receiver
9. Servomotor 19. Blow out coil
10.Piston 20. Arc chute

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

 Line contactors (6 No's) L1, L2, L3, L4, L5, and L6


in BA3 panel

 Shunting contactors (18 No’s) 9 Nos in BA1 and 9


No’s in BA3 panel

 Rheostatic Brake contactor C145 in BA3 panel

 C 118(in modified locos) in BA4 panel

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

Electro Pneumatic Contactors

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

Rheostatic Braking Circuit (WAG5)


C 145 Electro Pneumatic Contactor

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

 CGR1

 CGR2

 CGR3

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

CGR1,2 & 3

Used to give HT supply to TFP1 & 2 while changing the taps

In ODD Notch------------CGR1- Closes

In EVEN Notch-----------CGR2&3-Closes

In EVERY HALF Notch---CGR2-Closes

Location : HT2.

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

 JI
REVERSERS
 J2

 CTF1

 CTF2 CTFs

 CTF3
Phase II - Module No. STC-TRS-Conv.-02
CAMTECH, Gwalior

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

J1,J2 and CTF1, CTF2, CTF3

J1&J2- For Changing The Direction Of Loco

J1/J2 reverse the direction of current in the field of


respective TMs, thereby direction of rotation of motor is
changed.

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

CTF (3 Nos.)
Changes takes place in power circuit, and traction power
circuit becomes Rheostatic braking circuit.

 CTF1,2&3- Operating handle in Upwards- Traction mode

 CTF1,2&3- Operating handle is downwards-Braking Mode

Location:-
J1 & CTF1-----HT1-BA1
J2 & CTF2-----HT3-BA2
CTF3----------HT3-BA3
Phase II - Module No. STC-TRS-Conv.-02
CAMTECH, Gwalior

CTFs in Traction Power Circuit

Phase II - Module No. STC-TRS-Conv.-02


CAMTECH, Gwalior

Traction Motor Power Circuit (WAG5) Modified


J1/ J2 Drum Contactors

Phase II - Module No. STC-TRS-Conv.-02

You might also like