Derate Tables

1106A-70TG1
Diesel Engines

1106A-70TG1 @ 1500 rpm


Derate for high intake temperature and / or elevated altitude from ISO 3046 standard conditions, applies to tropical and temperate builds where applicable.

1106A-70TG1 50Hz Prime Power De-rate Chart


50.0%

45.0%
0degC
25degC
40.0% 34degC
43degC
35.0% 52degC

30.0%
De-rare [%]

25.0%

20.0%

15.0%

10.0%

5.0%

0.0%
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
Altitude [m]

Note: Ambient temperature at air cleaner inlet.

Publication No. TPD1980, February 2015.


Copyright © 2015 Perkins Engines Company Limited, all rights Perkins Engines Company Limited
reserved. No part of this document may be reproduced in any form Peterborough, PE1 5FQ, United Kingdom
or by any means, without prior written permission of Perkins Engines Tel: +44 (0)1733 583000
Company Limited. The information in this document is substantially Fax: +44 (0)1733 582240
correct at the time of printing and may be altered subsequently. www.perkins.com