3D Model review check-list (30%-60%-90% review): Topside-Fixed

Stage WBS

30% 1

30% 1.1

30% 1.1.1

30% 1.1.2

30% 1.1.3

30% 1.1.4

30% 1.2

30% 1.2.1

30% 1.2.2

30% 1.2.3

30% 1.2.4

30% 1.3

30% 1.3.1

30% 1.3.2

30% 1.3.3

30% 1.3.4

30% 1.4

30% 1.4.1

30% 1.4.2

30% 1.4.3

30% 1.5

30% 1.5.1

30% 1.5.2

30% 1.6
30% 1.6.1

30% 1.7

30% 1.7.1

30% 1.8

30% 1.8.1

30% 1.8.2

30% 1.9

30% 1.9.1

30% 1.9.2

30% 1.9.3

30% 1.10

30% 1.10.1

30% 1.11

30% 1.11.1

30% 1.12

30% 1.12.1

30% 1.12.2

30% 1.13

30% 1.13.1

30% 1.14

30% 1.14.1

30% 1.14.2

30% 1.15

30% 1.15.1

30% 1.16

30% 1.16.1

30% 1.16.2
30% 1.16.3

30% 1.17

30% 1.17.1

30% 1.17.2

30% 1.18

30% 1.18.1

30% 1.18.2

30% 1.19

30% 1.19.1

30% 1.19.2

30% 1.20

30% 1.20.1

30% 1.21

30% 1.21.1

60% 2

60% 2.1

60% 2.1.1

60% 2.1.2

60% 2.1.3

60% 2.1.4
60% 2.2

60% 2.2.1

60% 2.2.2

60% 2.2.3

60% 2.2.4

60% 2.3

60% 2.3.1

60% 2.3.2
60% 2.3.3

60% 2.3.4

60% 2.3.5

60% 2.3.6

60% 2.3.7

60% 2.3.8

60% 2.4

60% 2.4.1

60% 2.4.2

60% 2.4.3

60% 2.4.4

60% 2.4.5

60% 2.5

60% 2.5.1

60% 2.5.2

60% 2.5.3

60% 2.6

60% 2.6.1

60% 2.6.2

60% 2.6.3

60% 2.7

60% 2.7.1

60% 2.8

60% 2.8.1

60% 2.8.2

60% 2.8.3

60% 2.9

60% 2.9.1
60% 2.9.2

60% 2.9.3

60% 2.10

60% 2.10.1

60% 2.11

60% 2.12.1

60% 2.12

60% 2.12.1

60% 2.12.2

60% 2.13

60% 2.13.1

60% 2.13.2

60% 2.14

60% 2.14.1

60% 2.14.2

60% 2.15

60% 2.15.1

60% 2.15.2

60% 2.16

60% 2.16.1

60% 2.16.2

60% 2.16.3

60% 2.17

60% 2.17.1

60% 2.17.2

60% 2.17.3

60% 2.18

60% 2.18.1
60% 2.18.2

60% 2.19

60% 2.19.1

60% 2.19.2

60% 2.19.3

60% 2.20

60% 2.20.1
60% 2.20.2
60% 2.21

60% 2.21.1

60% 2.21.2

90% 3

90% 3.1

90% 3.1.1

90% 3.1.2

90% 3.1.3

90% 3.1.4
90% 3.2

90% 3.2.1

90% 3.2.2

90% 3.2.3

90% 3.3

90% 3.3.1

90% 3.3.2

90% 3.3.3

90% 3.3.4

90% 3.3.5

90% 3.3.6

90% 3.3.7
90% 3.3.8

90% 3.4

90% 3.4.1

90% 3.4.2

90% 3.4.3

90% 3.4.4

90% 3.4.5

90% 3.5

90% 3.5.1

90% 3.5.2

90% 3.5.3

90% 3.6

90% 3.6.1

90% 3.6.2

90% 3.6.3

90% 3.7

90% 3.7.1

90% 3.8

90% 3.8.1

90% 3.8.2

90% 3.8.3

90% 3.8.4

90% 3.9

90% 3.9.1

90% 3.9.2

90% 3.9.3

90% 3.10

90% 3.10.1
90% 3.11

90% 3.13.1

90% 3.12

90% 3.13.1

90% 3.13.2

90% 3.13

90% 3.13.1

90% 3.13.2

90% 3.14

90% 3.14.1

90% 3.14.2

90% 3.15

90% 3.15.1

90% 3.15.2

90% 3.16

90% 3.16.1

90% 3.16.2

90% 3.16.3

90% 3.17

90% 3.17.1

90% 3.17.2

90% 3.17.3

90% 3.18

90% 3.18.1

90% 3.19

90% 3.19.1

90% 3.19.2

90% 3.19.3
90% 3.20
90% 3.20.1
90% 3.20.2
90% 3.21

90% 3.21.1

90% 3.21.2
3D Model review check-list (30%-60%-90% review): Topside-Fixed Platform

Check-point Description

30% Model Review

Contents check

To check overall conditions and maturity more than 30%

To match the cooridination for the whole modeling

To check if plot plan was finalized after being commented by Company

Overall check - Unit location, equipment location, main access and escape routes to facilities, major
piping routes on PFD, arrangement around LLI (Long Lead Item), location of main manifolds, space
around equipment for maintenance, platforms for main operation access

Tagged Equipment (Packages)

General arrangement to be shown

Major equpment to be shown

All interface items like connecting pipes, footprint, and supports for structures

The largest item to be removed for maintenance issue.

Tagged Vessels

Access manholes to be modeled

For large vessel, two manholes shall be arranged

Access platform for top nozzles of vessels

No welding for PWHT (Post Weld Heat Treatment) vessel

Tagged Valves

All MOV (Motor Operated Valve), ESDV (Emergency Shut Down Valve) to be modeled

Major control valves to be modeled

Large bore manual valves with gear boxes to be modeled and not to be clashed with others

Escape, Evacuation, and lifesaving equipment

Lifesaving equipment like lifeboats, liferafts, lifebuoys to be modeled as boxes

Muster area to be modeled

Main escape routes


Main escape routes to be modeled with volume of PDMS or AM (Aveva Marine) - 1.2m witdth, 2.2m
height

No modeling of Switchgears inside electircal room and boards in technical room

Switchgears to be shown as boxes, not real model.

Location of lighting

Lighting location to be shown to check clashes

Clashed between lighting support pole and structural members to be checked

Piping headers

Piping headers like production headers, flare headers, export headers to be modeled

Maintenance area for piping headers and valves to be reserved

Access platform to be modeled for isolation vavles as boxes

Platform piping

Only Large-bore pipes above certain size to be modeled

Piping supports to be divided


To check if piping supports to be divided into two categories of special supports and others. Special
supports with high load to be modeled into structural members. Other smaller supports to be
modeled based on uniformly distributed load.

Electrical cable routes

To check if electriical cable routes are segregated from Instrument and Telecom cable routes.

Cable routes to be modeled above 200mm

Electrical and instrument cable route support

Big sized support to be modeled

Fire-fighting equipment

Fire-fighting equipment like hydrants, fire hose reels, extinguishers to be modeled as boxes

To check proper access to the fire-fiighting equipment

Proper coverage, insrument detectors

To ensure the proper coverage

Sprinklers in accomodation areas

Water nozzles to be shown in process area

The location and spray angle of nozzles to be checked


Required water discharge volume to be calculated (Refer the manufacturers' specifications)

Main junction boxes

Main junction boxes to be modeled

To check availability of cabling from junction boxes to the user

Instrument tubing

Normal sized intrument tubings as 8mm are not required to be modeled

Especially, large sized instrument tubing above 1.5" to be modeled

Online instruments

Online instruments to be modeled

Transmitter bodys to be located in an accessible location

Primary and secondary structures

Primary and secondary structures to be modeled to check clahses and possible supporting

Tertiary structures

Tertiary structures like handrails, stairs, ladders, access platforms to be shown

60% Model Review


Contents check

To check overall conditions and maturity more than 60%

To check all the pipe lines above 4"

Overall check - Location of individual items (valves, instruments, junction boxes, panels), arrangement
around equipment, location of fire-fighting equipment, confirm space around equipment for
maintenance, handling equipment (hoist, davit), access platform for operation
To check all the comments from 30% review by Company were incorporated onto the modeling
Tagged Equipment (Packages)

General arrangement to be shown

Major equpment to be shown

All interface items like connecting pipes, footprint, and supports for structures

The largest item to be removed for maintenance issue.

Tagged Vessels

Several nozzles to be modeled

Access manholes to be modeled


For large vessel, two manholes shall be arranged

Access platform for top nozzles of vessels

No welding for PWHT (Post Weld Heat Treatment) vessel

Wall thickness of Separators to be checked

Supporting saddles to be modeled for transportation and operating conditions

Expansion space to be allowed for high-thermal stresses

Tagged Valves

All MOV (Motor Operated Valve), ESDV (Emergency Shut Down Valve) to be modeled

All control valves to be modeled

Face to face dimensions, arrangement and dimensions of actuators

Acess for maintenance and removal of actuators

Large bore manual valves with gear boxes to be modeled and not to be clashed with others

Escape, Evacuation, and lifesaving equipment

All lifesaving equipment like lifeboats, liferafts, lifebuoys to be modeled

Dimension check for all the lifesaving equpiment

Muster area to be modeled

Main escape routes

Main escape routes to be modeled with volume of PDMS or AM (Aveva Marine) - 2.2m witdth, 2.2m
height

Other escape routes to be shown

No obstacle is allowable in the escape route

No modeling of Switchgears inside electircal room and boards in technical room

Switchgears to be shown as boxes, not real model.

Location of lighting

Lighting location to be shown to check clashes

Sufficient lux level to be checked by dedicated softwares

Clashed between lighting support pole and structural members to be checked

Piping headers

Piping headers like production headers, flare headers, export headers to be modeled
Maintenance area for piping headers and valves to be reserved

Access platform to be modeled for isolation vavles

Platform piping

All pipes above certain size to be modeled according to the Contract (usually above 2")

Piping supports to be divided


To check if piping supports to be divided into two categories of special supports and others. Special
supports with high load to be modeled into structural members. Other smaller supports to be
modeled based on uniformly distributed load.

Electrical cable routes

To check if electriical cable routes are segregated from Instrument and Telecom cable routes.

Cable routes to be modeled above 200mm

Electrical and instrument cable route support

Big sized support to be modeled

Small sized supports are not required to be modeled

Fire-fighting equipment

Fire-fighting equipment like hydrants, fire hose reels, extinguishers to be modeled

To check proper access to the fire-fiighting equipment

Proper coverage, insrument detectors

To ensure the proper coverage

Instrument detectors like gas/heat/flame/smoke detectors to be shown

Sprinklers in accomodation areas

Water nozzles to be shown in process area

The location and spray angle of nozzles to be checked

Required water discharge volume to be calculated (Refer the manufacturers' specifications)

Main junction boxes

Main junction boxes to be modeled

To check availability of cabling from junction boxes to the user

To check the proper area for the supporting of junction boxes

Instrument tubing

Normal sized intrument tubings as 8mm to be modeled


Especially, large sized instrument tubing above 2.5" to be modeled

Online instruments

Online instruments to be modeled

Transmitters to have a probe installed in-line and the signal by a cable to transmitter body

Transmitter bodys to be located in an accessible location

Primary and secondary structures

Primary and secondary structures to be modeled to check clahses and possible supporting
Almost all stiffeners and end connections of primary and secondary structures to be modeled
Tertiary structures

Tertiary structures like handrails, stairs, ladders, access platforms to be shown

To avoid clashes, ring/stiffener plates or star plates to be modeled as boxes

90% Model Review


Contents check

To check overall conditions and maturity more than 90%

To check all the sized pipe lines


Overall check - Access to all remaining items like flanged joints, and location of all the items as utility
stations.
To check all the comments from 60% review by Company were incorporated onto the modeling
Tagged Equipment (Packages)

General arrangement to be shown

Major equpment to be shown

All interface items like connecting pipes, footprint, and supports for structures

Tagged Vessels

All nozzles to be modeled

All access manholes to be modeled

For large vessel, two manholes shall be arranged

All access platform for top nozzles of vessels

Welding for PWHT (Post Weld Heat Treatment) vessel

Wall thickness of Separators to be checked

Supporting saddles to be modeled for transportation and operating conditions


Expansion space to be allowed for high-thermal stresses

Tagged Valves

All MOV (Motor Operated Valve), ESDV (Emergency Shut Down Valve) to be modeled

All control valves to be modeled

Face to face dimensions, arrangement and dimensions of actuators

Acess for maintenance and removal of actuators

All sized bore manual valves with gear boxes to be modeled and not to be clashed with others

Escape, Evacuation, and lifesaving equipment

All lifesaving equipment like lifeboats, liferafts, lifebuoys to be modeled

Dimension check for all the lifesaving equpiment

Muster area to be modeled

Main escape routes

Main escape routes to be modeled with volume of PDMS or AM (Aveva Marine) - 3.2m witdth, 3.2m
height

Other escape routes to be shown

No obstacle is allowable in the escape route

Modeling of Switchgears inside electircal room and boards in technical room

All Switchgears to be shown with actual models

Location of lighting

Lighting location to be shown to check clashes

Sufficient lux level to be checked by dedicated softwares

Clashed between lighting support pole and structural members to be checked

All lighting supports to be modeled

Piping headers

All piping headers like production headers, flare headers, export headers to be modeled

Maintenance area for piping headers and valves to be reserved

All access platform to be modeled for isolation vavles

Platform piping

All pipes above certain size to be modeled according to the Contract (usually above 2")
Piping supports to be divided
To check if piping supports to be divided into two categories of special supports and others. Special
supports with high load to be modeled into structural members. Other smaller supports to be
modeled based on uniformly distributed load.

Electrical cable routes

To check if electriical cable routes are segregated from Instrument and Telecom cable routes.

All sized cable routes to be modeled

Electrical and instrument cable route support

Big sized support to be modeled

Small sized supports are not required to be modeled

Fire-fighting equipment

Fire-fighting equipment like hydrants, fire hose reels, extinguishers to be modeled

To check proper access to the fire-fiighting equipment

Proper coverage, insrument detectors

To ensure the proper coverage

Instrument detectors like gas/heat/flame/smoke detectors to be shown

Sprinklers in accomodation areas

Water nozzles to be shown in process area

The location and spray angle of nozzles to be checked

Required water discharge volume to be calculated (Refer the manufacturers' specifications)

Main junction boxes

Main junction boxes to be modeled

To check availability of cabling from junction boxes to the user

To check the proper area for the supporting of junction boxes

Instrument tubing

All sized intrument tubings as 8mm to be modeled

Online instruments

Online instruments to be modeled

Transmitters to have a probe installed in-line and the signal by a cable to transmitter body

Transmitter bodys to be located in an accessible location


Primary and secondary structures
Primary and secondary structures to be modeled to check clahses and possible supporting
All the stiffeners and end connections of primary and secondary structures to be modeled accurately
Tertiary structures

Tertiary structures like handrails, stairs, ladders, access platforms to be shown

All ring/stiffener plates or star plates to be modeled accurately


Platform

Y/N