1.0 Introduction
Our lives are very much affected by the increasing level of noise in our The key objectives of this technical manual are to:
environment. As population continues to grow in the recent decades, so 1. Explain and highlight the growing concerns of urban noise and noise
has the amount of noise in our surrounding, be it coming from noisy around the environment of living and occupied spaces.
machines we employ at work or at home, and the activities that we 2. Explain the effects of unwanted sound or noise to occupants and
engage in while occupying a particular space for various purposes. users within the space.
3. Illustrate how sound and noise propagates through fundamental
However, the policies and guidelines regulating the ambient noise level knowledge on acoustics.
in our occupied spaces are still at its infancy stage. Hence it is important 4. Address the holistic concept of ambient noise level through
to address the need for having a comfortable environment in relations Noise Criteria (NC).
to the optimal ambient noise level and then subsequently the most 5. Provide suggestions that assist in the design and selection of
effective way to control it. specifications in accordance to the desired Noise Criteria (NC) values.
6. Provide examples and recommendations of materials and
The development of this technical manual is intended to provide specifications selection in the form of various case studies in
answers and solutions to address these concerns, as stated here. residential, office, educational and healthcare environments.
7. Assist consultants, building designers, contractors and project owners
on specifications and estimated ambient noise level and its controls.
3
Ambient Noise Control Technical Manual
Excessive level of noise causes us to suffer from distraction, In the educational environment, such as classrooms in schools or
fatigue and other unhealthy consequences. Noise from all kinds auditoriums in educational centres, excessive noise impedes the
of sources invades our homes and workplaces, whether coming learning process and degrades the learning experiences of its
from the traffic, aircraft, barking dogs or human voices. occupants, especially for kids and young adults.
Within the workplaces, we have office machines and equipment In addressing the noise problems of the built environment and
such as telephones, ventilation system and even conversations recommending effective solutions, it is important that we
between office cubicles causing unwanted noises which can be understand the basic physics of acoustics and how noise is
very distracting and lead to loss of concentration and produced and then seek ways to control it. Some common
productivity level. standpoints for this approach will be the source of the noise, the
path it travels and the point of receiving the noise. This manual
Noise from within the homes typically comes from household includes information on how to solve specific noise problems using
appliances, footsteps sound, and television sound that travel ROCKWOOL acoustical products and proprietary systems that are
across rooms, turning our homes into a hectic environment both safe and efficient.
instead of a place to rest and recuperate. The scenario for
healthcare sector is also very similar; where a good and
controlled acoustic environment is needed so that patients can
rest well with less stress for faster recovery.
4
Ambient Noise Control Technical Manual
3.0 Fundamentals of
Acoustics
5
Ambient Noise Control Technical Manual
Table 1: Octave Band Centre Frequency and One Diagram 2: Equal Loudness Curve
Third Octave Centres Loudness Level - Phons
120 120
Octave Band Band One Third Band 110
Centre Frequency Width Octave Centres Limits
100 100
Sound-Pressure Level - dB
22 22 90
31.5 25 28 80
80
31.5 35
70
44 40 44
60 60
63 50 57 50
63 71
40 40
88 80 88
30
125 100 113 20 20
125 141 10
176 160 176 Minimum
0 Audible 0
250 200 225
250 283 20 50 100 300 1 kHz 3 kHz 10 kHz 20 kHz
353 315 353 Frequency - Hz
Amplitude (Loudness)
The amplitude or loudness of a sound wave is expressed as
Sound Pressure Level (SPL). Sounds having the same wavelength
(equal frequency) may have differing loudness.
6
Ambient Noise Control Technical Manual
pain
120
auditory experience
100
orchestral range
80
dB SPL
60
vocal range
40
20
threshold of hearing
0
-20
10 100 1K 10K 20K
Frequency - Hz
Above diagram 3 shows the SPL in dB and in Pascal (Pa) for about 18000 to 20000 Hertz). However, the ears are more
various sounds within the human ear’s hearing range. It is worth sensitive to middle and higher-frequency sounds, around 500
noting for example that a sound pressure level of 60 dB is 1,000 Hertz to 8000 Hertz than to low frequency ones.
times that of the sound pressure level at 20 dB, instead of 3 times
in normal mathematical logic as the quantum is represented in a Different individuals will perceive sound intensities in relation to
logarithmic manner. frequencies differently as a matter of biological make up although
it is common that one’s ability to receive and interpret sounds will
As a rule of thumb, every 10 dB increase in sound level decrease with advancing age as hearing range could decrease to
corresponds to a “doubling of subjective loudness” so that, about 70 Hz to 14,000 Hz. Human also tends to hear a 4000 Hz
for example, a jackhammer noise at 110 dB would typically be tone as being louder than a tone at some other frequency, even
judged to be 2 x 2 x 2 x 2 = 16 times as loud as the inside of a though the acoustical energy, or sound power could be the same.
house at 70 dB.
In order to mimic and normalise the ear’s sensitivity, weighting
The human ear is sensitive to a wide range of sound intensity system or correction factor is introduced. The common correction
(loudness); from ticking of a watch to jet engine noise in rather factor that is used to represent noise level in relation to human
close proximity, would typically result in a pain sensation in the perception is called A-weighting; there are also several other
ears. The human ear is also sensitive to a wide range of sound weightings available but they are more suitable for other
frequencies, ranging from very low (like the sound from a purposes and studies.
sub-woofer, around 20-30 hertz) to very high (aircraft sound,
7
Ambient Noise Control Technical Manual
The A-weighting factor is commonly embedded into sound level Diagram 4 is a Decibel Scale showing sound levels
meters for noise measurement as a form of electronic filter. typically created by familiar sources of noise in the home
This weighting is used when measuring sound in the community or and community.
the workplace and the resulting sound levels are expressed in units
of A-weighted decibels, or dBA.
In general the correction factor results in noise level with Threshold of pain 130
suppression to low frequencies sound; and due to frequencies
dependent, overall noise level measured is typically lower
compared to noise level expressed in dB. 747 on take off 120
Quiet livingroom 40
Whisper
20
10
Threshold
of hearing
0
8
Ambient Noise Control Technical Manual
2 or 3 dB 2 dB c. Impulsive Sound
Unusually loud sound that is startling or shocking to the listeners
4 to 9 dB 1 dB
Noise generated in an impulse or very short period of time
10 dB or greater 0 dB Example such as sound of an explosion
If loud enough, impulsive sound can cause hearing damage
9
Ambient Noise Control Technical Manual
To differentiate sound from noise involves personal subjective Sound with long wavelengths (low-pitched sounds) tend to diffract
judgement based on the individual’s sensitivity and tolerance around objects more readily than sound with short wavelengths.
towards sound, coupled with the attitude and experience or This makes shielding a noise receiver from low-frequency sounds
exposure of the individual to sound. For one person the sound more difficult compared to shielding noise of other frequencies.
may be perceived as soothing and comfortable but by another Low-pitched sounds also pass through solid materials easily.
perceived as noise or unwanted sound. However, high-pitched sounds with short wavelengths can pass
through small cracks and gaps more easily than low-pitched sounds.
It is difficult to completely eliminate the characteristics of
sound like pure tones such as whines and humming or impulsive Hearing Loss
components such as gun-shot sound or barking dogs that is At high sound intensities, noise can cause temporary or permanent
continually coming on and off. Such undesirable sound interferes hearing loss. This can be due to very loud sound like lightning
with our quality of life during rest and sleep, our ability to thunder or a gun-shot from a short distance. When we are exposed
converse clearly or even when listening to music or other to such occupational noise environment it can cause damage to our
natural sounds. The unwanted sound creates unpleasant feelings hearing over time. Therefore, as part of occupational safety
or fears, so much so that sometimes we find it difficult to express requirement it is recommended that a person should not be
our discomfort when we are experiencing it. exposed to noise level more than 85 dBA for a continuous of
8 hours a day. Hearing damage could be in the form of not being
Therefore, the unwanted sound or noise is widely recognised as able to hear certain frequency or not being able to listen to sound
a form of environmental pollution. Even though noise is created lower than certain loudness.
from human activities, we must weigh the rights of others to
enjoy peace and quietness in their residential space, within Speech Intelligibility
neighbourhoods, and at public areas such as educational and The impact of noise on speech communication is huge. This happen
healthcare centres. when intrusive noise exceeds the normal speech sound levels and
when the noise ‘mask’ the speech sound, causing loss of speech
The noise annoyance is also subject to other factors when intelligibility. The recommended practical noise level threshold for
viewed from the degree of impact it brings and how much it the onset interference with speech intelligibility is capped at 45 dBA
influences one’s lives. These factors include the following: for steady noises and 55dBA for intermittent peak levels.
10
Ambient Noise Control Technical Manual
NC 55
For example, moderate ambient sound level can be helpful in 50
others; yet the level should not make it difficult for the NC 45
occupants within the same room to converse clearly with each 40
NC 30
Depending on the usage of space and type of building,
background noises or ambient noise levels need to the
20 NC 25
designed and checked with good sound control to enable
good indoor comfort and clear speech intelligibility. NC 20
10 Threshold of Hearing
0
63 125 250 500 1000 2000 4000 8000
11
Ambient Noise Control Technical Manual
5.1 Noise Criteria (NC) Referring to the Diagram 5, the NC rating curves are plotted in
Noise Criteria (NC) is one of the important parameters used in such a way that the sound pressure level is adjusted to reflect
measuring the allowable ambient sound level for various types the behaviour of human ear in response to the respective octave
of interior spaces. NC rating is determined through plotting band centres of frequencies.
measured ambient noise level spectrum over an NC Chart;
where NC rating curves is pre-plotted. By referring to the NC The recommended NC sound level for various interior
curves, the NC rating is taken at the nearest curve that the spaces is shown in Table 4.
plotted ambient noise curve did not cut through. This is the
lowest NC rating possible for a particular interior space.
Concert and recital halls Listening to both loud and faint sounds 10 - 20
Living rooms and family roos Clear conversation among a small group 35 - 45
12
Ambient Noise Control Technical Manual
3 2 2 3
1 1
S 3 3
M
2 4 4 2
4 4
2
2
13
Ambient Noise Control Technical Manual
Field measured STC values need to cater for losses in the STC The best practice of maintaining a reasonably good sound level
performance due to the nature of the installation flaws and within an interior space is to enclose or encase the source with
unintended ambient noise that exist on site, influencing the housing that is constructed with materials of high STC ratings. The
measurement of the on-site transmission loss. Field STC is enclosure should be designed and built with caution so that there
denoted as FSTC. For the design of FSTC, it is estimated at are no air gaps that will cause sound leakage from the enclosure
approximately a difference of 5-8 rating of STC from the actual through these small gaps.
STC value.
14
Ambient Noise Control Technical Manual
7.2 Consideration on Flanking Paths Examples of flanking paths include door and window gaps and
To determine the sound transmission loss in relation to the improperly sealed joints between wall panels and sockets and
desired ambient sound, careful consideration must be given to openings for mechanical and electrical service fittings. In order to
flanking paths. The flanking path is defined as the route or the reduce the flanking noises, below measures are recommended:
path that sound travels from one space to another space which
is not through the main separating element. Any gap or small
opening in an acoustically designed space will lead to sound
leakage and this will increase the ambient noise level.
15
Ambient Noise Control Technical Manual
Sound absorption is defined as the ability of a material to It is calculated with the average sound absorption coefficient at
transform acoustical energy to other forms of energy, typically specific frequencies of 250, 500, 1000 and 2000 Hz.
heat. Some materials will absorb sound energy differently;
materials such as concrete and brick wall absorb very little to In order for a material to be considered as having sound absorption
none acoustical energy and reflect most of the sound energy properties, a minimum NRC value of 0.50 is required.
that strike its surfaces, whereas porous material such as
ROCKWOOL stone wool products absorb most of the sound Table 6 shows the typical values of NRC for various types of
energy that it comes in contact with. materials.
8.1 Noise Reduction Coefficient (NRC) The NRC values of a material is used to calculate the sabin of
The sound absorption criteria is usually expressed in terms of absorption which is the unit of measuring sound absorption that
percentage or as the decimal fraction of the sound energy equals to the sound absorption coefficient of a material multiply
absorbed and not reflected by the materials. Different materials with the coverage surface area that is used. The sabin of absorption
will behave differently in absorbing sound energy at different is then used in calculating the noise reduction in an interior space
frequencies. Building materials are generally rated with a single and reverberation time, RT60.
number rating called Noise Reduction Coefficient (NRC).
Table 6: One third- octave sound absorption coefficients of typical building materials
Brick, unglazed, painted 0.01 0.01 0.02 0.02 0.02 0.03 0.00
Concrete block, painted 0.10 0.05 0.06 0.07 0.09 0.08 0.05
Carpet, 1/8" pile height 0.05 0.05 0.10 0.20 0.30 0.40 0.15
Carpet, 1/4" pile height 0.05 0.10 0.15 0.30 0.50 0.55 0.25
Carpet, 3/16" combined pile and foam 0.05 0.10 0.10 0.30 0.40 0.50 0.25
Carpet, 5/16" combined pile and foam 0.05 0.15 0.30 0.40 0.50 0.60 0.35
Fabric, light velour, 10 oz./sq. yd. hung straight in contact with wall 0.03 0.04 0.11 0.17 0.24 0.35 0.15
Fabric, medium velour, 14 oz./sq. yd. draped to half area 0.07 0.31 0.49 0.75 0.70 0.60 0.55
Fabric, heavy velour, 18 oz./sq. yd. draped to half area 0.14 0.35 0.55 0.72 0.70 0.65 0.60
Floors, concrete or terrazzo 0.01 0.01 0.01 0.02 0.02 0.02 0.00
Floors, linoleum, asphalt, rubber or cork tile on concrete 0.02 0.03 0.03 0.03 0.03 0.02 0.05
Floors, wood parquet in asphalt or concrete 0.04 0.04 0.07 0.06 0.06 0.07 0.05
Glass, 1/4", selaed, large panes 0.05 0.03 0.02 0.02 0.03 0.02 0.05
Glass, 24 oz. operable windows, closed 0.10 0.05 0.04 0.03 0.03 0.03 0.05
From "Acoustical Ceilings — Use and Practice," Ceilings and Interior Systems Contractors Association (1984). p.18.
16
Ambient Noise Control Technical Manual
8.2 The Need and Properties for Sound Absorbers 8.4 Reverberation Time
Porous materials have interconnecting air pockets and are an Reverberant sound or also known as echo in an interior space will
effective sound absorber. ROCKWOOL Safe ’n’ Silent Pro when fade away with time as the sound energy is absorbed multiple times
coupled with thin or perforated surfaces such as fabric lining and and reflected within the surfaces of the room itself. If the surfaces of
perforated panels, is a good sound absorber that performs well the room are all made of hard and non-absorptive materials, it takes
to reduce unwanted noise in a space. This can be achieved by longer time for the echo to die off, thereby causing disturbance to
placing the materials on the surface of the walls within an the occupants, reducing speech intelligibility and affects
interior space. concentration.
8.3 Sound Level Reduction Calculation Reverberation time of RT60 is defined as the time needed for the
The reduction of sound level in a room is related to the amount sound to reduce by 60 dB from its original sound level. It is then
of sound absorption surfaces in the room itself. The reduction of calculated and modelled through the usage of absorptive materials
sound level can be expressed as: in the interior space. In room acoustics, it is important to have a
good reverberation time to ensure occupants' activities are not
Reduction in sound level = 10 log Aa/Ab dB, impaired or affected.
Where Aa is the sound absorption in sabins in the room
after correction The Reverberation time is expressed as:
Ab is the sound absorption in sabins in the room RT60 = 0.161 (V/A) in seconds, where
before correction V = Volumetric size of the room
A = Sabins of absorption in the room
In instances where an interior space is noisy due to occupant
activities such as a music hall or auditorium, and the sound level The example uses a room volumetric size of 5000 cu. meters with
may need to be controlled and minimised to a low level, the amount of sabins of absorption at 200 sabins at 250Hz. After
equation above can be used to determine the amount of installation of wall absorbers with total sabins of 1000 sabins,
acoustical absorption materials needed in order to meet such this gives a total of 1200 sabins.
requirements.
The RT60 before the acoustical correction is calculated as 4.0
For example, for wall absorbers using ROCKWOOL seconds whereas after adding in wall absorbers, the RT60 becomes
Safe ’n’ Silent Pro with sound absorption coefficient of 0.70 at 0.67 seconds.
250 Hz, with a coverage surface area of 1000 sq. meters, we
assumed the total sabins of absorption in the room from all This lower reverberation time provides a comfortable and clear
other absorptive surfaces at 250 Hz is 200 sabins. The wall speech intelligibility to the occupants using the room.
absorber contributes total sabins of 0.70 x 1000 = 700 sabins so
when added to the room is 200 + 700 = 900 sabins.
17
Ambient Noise Control Technical Manual
This manual has so far discussed about how sound propagates Controlling Noise at the Receiver
and the means of calculating the effects of sound whether it is When the first two methods fail to meet the noise controlling
being reflected or absorbed in a room. Hence, we should now criteria, we can also find ways to fix the noise problem at the
consider ways of how to control the sound via its sound paths, receivers end.
from the sound source, the travel path and the receiver end of
the sound. The acoustical consideration range takes into 9.1 Noise Control Mistakes to Avoid
account all the way from the starting point where the sound Thinking That There is No Noise Problem
originates to everything in between, until it reaches the In an industrial environment of a factory, if workers are exposed to
receivers’ ears. ambient noise level of more than 85 dBA it is considered hazardous.
Ear protectors should be used as a temporary measure while the
Controlling Noise at the Source use of actual enclosure for the loud noise must be deployed.
The following measures can be considered in order to control Another example is in the educational environment where a 55 dB
the noise at the source itself. It is the least costly way of reducing sound in a learning centre will cause difficulty in listening and poor
noise, but often is limited by the site condition or the activities in speech intelligibility that can impair the learning process.
the room itself, sometimes making it impossible to make
changes to the sound source. Not Considering Noise Control Before a Project is Started
It is estimated that the cost to correct the acoustic performance of a
Move the source to another location at a certain room is almost double or the measures are only half as effective if
distance away, so that the noise level is lower. done after the completion of a construction. We therefore
Change the acidity related to the generated noise so that recommend that the acoustic performance be determined at design
the sound level is reduced; for example reducing motor stage and the installation starts during the design and specification
power or speed of rotating drum of equipment. stage before the sound source is introduced or the occupant activity
Repair faulty equipment that generates noise such as loose occurs.
bolts and nuts from vibration.
Replace equipment with a quieter type or model. Not Conducting a Detailed Study of Noise Equipment
Equipment and machineries always emit noises that can cause
Another method of containing and reducing the sound from its uneasiness to the users and occupants and these must be
source is by having an acoustical housing that encloses the addressed and considered when controlling the ambient noise level.
sound generating activity or equipment. The housing needs to The spectrum of noise in terms of frequencies should be analysed
be designed with high sound transmission loss properties. It also and the octave band noise levels obtained and studied beforehand.
needs to be covered with high sound absorptive material to By doing so we can better understand the overall noise generated
increase the overall noise reduction level. by the equipment and thereafter design the control mechanism to
reduce the ambient noise.
Controlling Noise Along its Path
As mentioned in sound absorption topics, reverberant sound
resulting in echo can be reduced by placing sound absorbing
materials on the surfaces which reflects the sound. This
contributes significantly to the final outcome of the acoustical
correction in order to produce a desired comfortable
environment. It is also one of the least expensive ways to design
and construct noise controlling mechanisms compared to
controlling the sound source.
18
Ambient Noise Control Technical Manual
Not Using a System Approach to Noise Control 9.2 Case Studies – Assumptions and Presets
Noise control involves a system approach rather than just one The following sections of this manual include several simulated case
single material or product. All possible noise paths and solutions studies where ambient noise levels are recommended for various
that could lead to higher noise level need to be considered categories of room/space functions. Examples are provided
whether before, during or after the construction works are showing the various acoustics elements combined to achieve the
carried out. In this case, airborne and structure borne sound desired ambient noise level. Relevant acoustics design elements
must be studied and understood thoroughly. and other related elements are described hereafter as well. It is
assumed that the external noise source of related room/space is in
Not Sealing Air Leaks the range of 70 to 80 dB(A). Examples of such external noise
Sound will pass through even from the smallest gaps or cracks sources are passing traffic, student activities, music or
whether they are from the construction itself or the architectural announcements from portable sound reinforcement.
finishes. Wherever there are air leaks, sound can pass through
from one space to another, causing higher ambient noise The partitioning elements of the room/space were designed based
thereby defeating the purpose of having high acoustic on estimated calculation of commonly used Mass Law equation
performance solutions. So it is important that air leaks are sealed which is an empirical estimation method. Elements such as doors,
properly to avoid such problems. ceiling panels, carpets and others are generally available in the
market.
The simulated case studies are for reference and to provide general
understanding; other design and construction details may not be
listed herein and may require further attention. It is recommended
that the partitioning elements be laboratory tested before
implementation on site.
19
Ambient Noise Control Technical Manual
A residential unit is a place where people live and spend a In order to achieve the recommended ambient noise level,
good amount of time in. Typically it consists of several appropriate airborne sound isolation performance for various
bedrooms, a living area, toilets and kitchen; and is designed to partying elements, noise control on mechanical equipment and
provide comfort to those living in it. Some houses have introduction of interior finishes with acoustics enhancement
additional rooms or spaces that serve as audio visual room, properties/elements would be required where appropriate.
leisure and games room/space, library, study room and so on.
These additional luxury of room and space means that the 10.2 Ambient Noise Level Consideration
residential unit becomes a common place for both dwelling and Residential unit typically requires reasonable airborne sound
leisure. isolation performance; apart from isolating external noise, it is also
for isolating noise intrusion or cross-over between rooms/spaces.
10.1 Use of Space and Occupancy
Different rooms have a different function and require different More importantly a good sound isolation is needed between units,
conducive ambient noise level. Table 7 recommends conducive such as between terrace houses, semi-detached houses,
ambient noise level and noise criteria for various rooms and condominiums, apartments and other similar housing configurations.
spaces for a residential unit.
20
Ambient Noise Control Technical Manual
BEDROO M 3
BEDROO M 2 2
BATH 3 ENTRY
BATH 2
YARD/UTI LITY
FOYER
3
MA STER 6 7
BATHROOM KITCHE N
AV ROOM
STUDY 5
PENTHOUSE D 4
MA STER BEDROOM
LIVING AREA
DININ G AREA
Tolerance to sound crossover between rooms and spaces within Table 7: Recommended NC/NR rating and Ambient Noise
the same unit is usually higher; but not between 2 connecting Level for various room/space for a residential unit
units. Also, additional consideration is needed for residential
Recommended Rating
estate or project which is situated next to a busy expressway, Space / Room
railway line, transit line, and/or airport. NC Noise Level
Bedrooms 30 – 40 35 – 45 dB(A)
Indoor ambient noise of these residential estates are likely to be
affected by traffic noise, train noise and/or aircraft noise. Hence Study Area 30 – 40 35 – 45 dB(A)
provision for high airborne sound isolation performance should
AV Room 35 – 40 40 – 45 dB(A)
be considered for facade glazing or external wall of the building;
apart from setting building orientation and layout as part of the Living Area 35 – 45 40 – 50 dB(A)
effort to keep external noise intrusion to a minimal.
Kitchen 45 – 50 50 – 55 dB(A)
21
Ambient Noise Control Technical Manual
Ideally, noise crossover between internal spaces and rooms of a 10.3 Bedrooms and AV Room
unit is to be kept to a minimal in order to meet proposed Common residential unit's interior finishes are for example plaster
ambient noise level. A person sleeping in the bedroom should ceiling, plaster and paint walls and homogenous tiles. Acoustics
not be disturbed by the television sound in the living room; or ceiling, absorptive wall panels and/or diffusive panels which are
the audio sound from the AV Room should not leak and disturb used to enhance the acoustics environment would likely be seen in
other family members carrying out their activities in other parts an AV Room only; unless otherwise intended for other areas.
of the unit.
Sound reverberation and flutter echoes can be reduced to a minimal
Unfortunately, often sound leaks and intrusion happens through with built-in and loose furniture; and other decorative items. These
the door gap; even though partitioning wall and door has been items diffuse noise energy and breaks noise reflection path. At the
carefully designed and selected. This compromises the overall same time, the shape, dimensions and volume of a residential unit
airborne sound isolation performance of the partitioning generally does not further encourage flutters and echoes.
elements. So, whenever possible door seals are recommended.
Introduction of acoustics elements in an AV Room is essentially to
As to limiting noise intrusion, ambient noise level of a residential enhance its acoustics environment; resulting in a pleasant aural
unit is also dependent on other noise generating sources experience coupled with the audio visual system.
typically by long running period equipment such as the ACMV
system. Elements introduced here could be absorptive, diffusive and/or
mixed of the two. The common idea is to create a well distributed
High end high rise residential units are likely to be equipped sound environment and at the same time with minimal sound
with centralized ACMV system which generally allows noise reverberation, echo and flutter. This will boost the audibility and
mitigation to be introduced within the system to ensure resultant speech intelligibility which further enhances the experience.
noise propagated would not compromise the desired ambient Elements such as acoustics absorptive wall panels with fabric and/or
noise level. perforated timber finish, acoustics absorptive ceiling, timber raised
floor with vibration isolators and carpet are typically seen as part of
Mitigation measures include sound isolation box of a fan coil AV Room design.
unit, internally lined duct, acoustics silencer, low noise air-grille
and others. As AV Room often operates under high sound level condition;
consideration on improving the sound isolation performance of the
On the other hand, general residential units utilise standalone perimeter walls and doors would be essential to reduce noise
systems such as ceiling fan, stand fan, split-unit air conditioning impact to other areas within the unit or even to other connecting
unit and air cooler as part of the home cooling. Special selection units.
would be required to ensure that noise emission does not
compromise the desired acoustics environment. The following section proposed construction details and
recommendation on ACMV which serves as a guide in order to
Notwithstanding the ACMV system, the operations of electrical meet desired ambient noise level as prescribed above.
or mechanical products that emit noise and run for long periods
of time should also be reviewed when a certain ambient noise
rating needs to be achieved.
22
Ambient Noise Control Technical Manual
1 Building a) 50mm ROCKWOOL Safe 'n' Silent Pro Perforated panel finish on
Envelope or b) Perforated panel with minimum opening the internal side of the
Facade a area of 15 - 20% facade (brickwall)
provides sound
b c) 100mm thick brick wall, with 20mm thick absorption performance
plastering on both sides and 8mm thick and prevent thermal heat
casement window transfer, lowering U-value
c
Curtain glass wall could be in form of of building envelope.
double glazed for better sound isolation
performance.
2 Party Wall a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro Wall to construct to full
between b) 2 x 12 mm thick Plasterboard height
Bedrooms a (min. density 650 kg/cu.m)
b c) 2 x 12 mm thick Plasterboard
c (min. density 650 kg/cu.m)
d) 92 mm deep stud
3 Party Wall a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro Wall to construct to full
between AV b) 2 x 12 mm thick Plasterboard height
Room and a (min. density 650 kg/cu.m)
other b c) 2 x 12 mm thick Plasterboard
Separated or twin studs
spaces/ are sized according to
rooms c (min. density 650 kg/cu.m) maximum height of wall
d) Separated Stud system.
d e) 150 mm deep air cavity
23
Ambient Noise Control Technical Manual
4 Party Wall a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro Wall to construct to
between a b) 100 mm thick clay brick full height
Residential (min. density 1500 kg/cu.m)
Units
b
c c) 100 mm thick clay brick
(min. density 1500 kg/cu.m)
d d) 20 mm thick plastering (on 3 sides)
e e) 100 mm deep air cavity
5 Party Wall a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro Wall to construct to full
for b) 2 x 15 mm thick moisture resistant height
Kitchen plasterboard (min.density 650 kg/cu.m)
Wall choices to suit
a c) 2 x 15 mm thick moisture resistant requirements in wet areas
b plasterboard (min.density 650 kg/cu.m) by using moisture or water
c d) 92 mm deep stud resistant board, and
installation to cater for
additional loadings from
wall tiling and penetrating
d services.
6 Acoustics Fabric Finish a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro NRC 0.6- 0.8
Wall b) Wire mesh to support ROCKWOOL layer Sound absorption will
Panel increase with additional
a c) 5 – 10 mm foam 50 mm air cavity behind
b d) Acoustics transparent fabric insulation layer
c
d
Perforated Panel Finish a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro NRC 0.6- 0.8
b) Perforated panel with minimum opening Typically to treat 60 – 75%
area of 15 - 20% of side and rear wall areas
a
b
24
Ambient Noise Control Technical Manual
* Door Solid wood core door with well-designed Bottom door seals will
door frame and ironmongery, STC rating improve sound intrusion
or sound leakage – best
30-32. use for AV Room
* Centralized Air Handling Unit/ To select fan with low noise unit as stated FCU may require
Air Fan Coil Unit in laboratory testing (by manufacturer's acoustics box up if
Conditioning installed within sensitive
with delivery testing) room or space
ducts
Diffusers To select diffusers with low regeneration Noise will generate when
noise; especially for noise sensitive room excessive air and/or high
velocity air flows through
diffusers blades; hence
the selection
25
Ambient Noise Control Technical Manual
An office is the place where a commercial establishment has its In order to achieve the recommended ambient noise level,
work and conduct related matters. It is not a place for manual appropriate airborne sound isolation performance for various
hard labour; employees mainly work on administrative, design partying elements, noise control on mechanical equipment and
related and/or sales related work. introduction of interior finishes with acoustics enhancement
properties/elements would be required where appropriate.
Employees typically spend more than 8 hours in an office thus it
is important for office workers to have a conducive environment Table 8: Recommended NC/NR rating and Ambient Noise
with good acoustics climate. Level for various room/space for an office unit
Recommended Rating
It has been confirmed by researches that an office with good Space / Room
acoustics climate and low ambient noise level could actually NC Noise Level
boost employees’ concentration and thereby their productivity
CEO, CFO, COO Room 35 - 40 40 – 45 dB(A)
as well.
Meeting Room / Board Room 35 - 40 40 – 45 dB(A)
Hence a well-designed acoustics environment is beneficial for
Executive Office 40 - 45 45 - 50 dB(A)
both employees and employers.
Open Office 40 - 45 45 - 50 dB(A)
11.1 Use of Space and Occupancy
Lift Lobby, Foyer and Circulation 45 – 50 50 – 55 dB(A)
Table 8 recommends the conducive ambient noise level and
noise criteria for various rooms and spaces for an office. Pantry 45 – 50 50 – 55 dB(A)
Toilets 50 – 55 55 – 60 dB(A)
Generally, rooms or spaces use for the purposes of office work,
meeting and productivity related work are recommended to
have low ambient noise level; while supporting facilities which
deals with other types of activities which can tolerate moderately
higher noise level.
26
Ambient Noise Control Technical Manual
11.2 Ambient Noise Level Consideration As for limiting noise intrusion, ambient noise level of an office could
Office is usually by choice located in a prime commercial zone, be dependent on noise generating sources typically by long
among all the hustle and bustle of commercial and human running period equipments; such as the ACMV system.
activities. It is also likely to be surrounded by heavy trafficked
roads, train stations, bus routes and possibly even close to an Office in a commercial or office tower is likely to be equipped with
airport. This places the office in an environment of high noise centralized ACMV system which typically allows noise mitigation to
level. be introduced within the system to ensure resultant noise
propagated would not compromise the desired ambient noise level.
Hence, in order to maintain the desired interior ambient noise
level, design of an office tower or commercial building has to Mitigation measures includes selection of quieter air handling unit
provide for sufficient airborne sound isolation between the (AHU), sound isolation box of a Fan Coil Unit, internally lined duct,
external and internal of the building, between floors and acoustics silencer, low noise air-grille and others.
adjacent office units.
On the other hand, smaller offices or home offices utilises
Also equally important is to provide internal partitioning stand-alone system such as ceiling fan, stand fan, split-unit air
elements with reasonable airborne sound isolation, as part of conditioning unit and air cooler as part of its home cooling. Special
the effort to contained noise/sound at its source. This is highly selection would then be required to ensure that noise emission
relevant as it relates to sound crossover and speech privacy does not compromise the desired acoustics environment.
issues; apart from maintaining the desired ambient noise level.
Notwithstanding the ACMV system, the operations of electrical or
An interview or confidential discussions are not appropriate to mechanical products that emit noise and run for long periods of
be overheard by other employees outside of the interview or time should also be reviewed when a certain ambient noise rating
meeting room. Private tele-conversation among employees needs to be achieved.
which could be heard in the adjacent room could also prove to
be inappropriate and may spark disagreement or lead to privacy
intrusion issue.
27
Ambient Noise Control Technical Manual
LIFT LOBBY
MECHANICAL
PLANT ROOM PANTRY STORAGE
MEETING ROOM/ 2
BOARD ROOM CEO OFFICE CFO OFFICE COO OFFICE OPEN OFFICE
6
1
7
11.3 Meeting Rooms and Workstations It is common that a meeting room is finished with plaster ceiling,
Meeting rooms or board rooms are commonly regarded as mixture of glass and timber panelling works as interior design
critical rooms. This is a place where a company direction, policy, input and maybe with carpets as well. To improve the acoustics
commercial and financial related matters are discussed and absorption through noise reverberation control, acoustics
decisions are made. Hence contents of any meeting or panelling of either absorptive or diffusive type can be introduced.
discussion can be considered as highly confidential and should This will boost the audibility and speech intelligibility and further
always be regarded as "only within the four walls ". Apart from enhances the listening experience.
its privacy needs, meeting rooms should be a place where
speech intelligibility should not be compromised. Employees are typically placed in an open office space with
individual workstation which commonly does not provide for
Hence acoustics input towards its construction includes intensive acoustics environment. In an open office concept,
providing good sound isolation performance, good interior acoustics inputs would be in the form of providing acoustics
acoustics and also sound mitigation to control ACMV noise. ceiling panels, carpet, and providing for low noise ACMV system.
Equipment used within the meeting room should also be
considered in terms of its noise intensity. Acoustics ceiling panels are to control sound reverberation and
carpets to reduce walking and impact noise from heels. Whereas a
With all these measures, a meeting room's ambient noise level controlled ACMV system would also help in not compromising the
could be preserved, would be annoyance free, and able to desired ambient noise level.
maintain its role in providing privacy of space for discussions.
The following section proposed construction details and
recommendation on ACMV which serves as a guide in order to
meet desired ambient noise level as prescribed above.
28
Ambient Noise Control Technical Manual
2 Meeting a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro Wall to construct to full
Room Wall/ a b) 2 x 16 mm thick Plasterboard height
CEO, COO, b
CFO Office (min. density 650 kg/cu.m)
c c) 2 x 16 mm thick Plasterboard
Wall
d (min. density 650 kg/cu.m)
d) 92 mm deep stud
3 Executive a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro Wall to construct to full
Office Wall a height
b) 2 x 12 mm thick Plasterboard
b
(min. density 650 kg/cu.m)
c
c) 2 x 12 mm thick Plasterboard
d
(min. density 650 kg/cu.m)
d) 75 mm deep stud
4 Mechanical a) 50mm ROCKWOOL Safe 'n' Silent Pro Wall to construct to full
Plant Room b) Perforated panel with minimum opening height
Wall a
area of 15 - 20%
b All round or all 4 sides ofthe
c) 20 mm thick plastering (both sides) room should be full height
c
d) 210 mm thick clay brick
d Wall choices to suit
requirements of building
fire codes and other related
installation requirements.
5 Toilet Wall a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro Wall to construct to full
b) 2 x 15 mm thick moisture resistance height
plasterboard (min. density 650 kg/cu.m)
c) 2 x 15 mm thick moisture resistance Wall choices to suit
plasterboard (min. density 650 kg/cu.m) requirements in wet areas
a
d) 92 mm deep stud by using moisture or water
b resistant board, and
c installation to cater for
d additional loadings from
wall tiling and penetrating
services.
29
Ambient Noise Control Technical Manual
6 Pantry Wall a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro Wall to construct to full
b) 12 mm thick Plasterboard height
a (min. density 650 kg/cu.m) Where dry wall is suitable
b c) 12 mm thick Plasterboard for construction
c (min. density 650 kg/cu.m)
Plasterboard with water
d d) 75 mm deep stud
resistance treatment
preferred
7 Acoustics Fabric Finish a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro NRC 0.6- 0.8
Wall Panel b) Wire mesh to support ROCKWOOL layer Sound absorption will
increase with additional
a c) 5 – 10 mm foam 50 mm air cavity behind
b d) Acoustics transparent fabric insulation layer
c
Typically to treat 60 – 75%
d
of side and rear wall areas
Perforated Panel Finish a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro NRC 0.6- 0.8
b) Perforated panel with minimal opening area Sound absorption will
a of 15 - 20% increase with additional
b 50 mm air cavity behind
insulation layer
30
Ambient Noise Control Technical Manual
* Door Solid wood core door with well-designed Bottom door seals will
door frame and ironmongery, STC rating improve sound intrusion or
sound leakage
30-32.
* Centralized Air Air Handling Unit/ To select fan with low noise unit as stated FCU may require acoustics
Conditioning Fan Coil Unit in laboratory testing (by manufacturer's box up if installed within
with delivery sensitive room or space
ducts testing)
Diffusers To select diffusers with low regeneration Noise will generate when
noise; especially for noise sensitive room excessive air and/or high
velocity air flows through
diffusers blades; hence the
selection
31
Ambient Noise Control Technical Manual
Acoustics elements are typically introduced to critical rooms/ In order to achieve the recommended ambient noise level,
spaces of an institution; especially to improve interior acoustics appropriate airborne sound isolation performance for various
environment which includes: partying elements, noise control on mechanical equipment and
Auditorium / Lecture Theatre / Seminar Room introduction of interior finishes with acoustics enhancement
Library properties/elements would be required where appropriate.
Video Room, Music Room
Studio (music or recording)
32
Ambient Noise Control Technical Manual
12.2 Ambient Noise Level Consideration As for limiting noise intrusion and crossover, ambient noise level of
As discussed in previous section, conducive acoustics an educational institution could also be dependent on the noise
environment with reasonable level of ambient noise is essential generating sources typically from long running period equipments
for a teaching and learning facility. such as ACMV system.
Airborne sound isolation performance of partying elements Large rooms, for example auditoriums, lecture theatres and library
for each room/hall/theatre/space hence becomes important to are likely to be equipped with centralized ACMV system which
avoid external noise intrusion and/or noise cross over between typically allows noise mitigation to be introduced within the system
them. to ensure resultant noise propagated would not compromise the
desired ambient noise level.
Additional consideration would need to be taken for an
Educational Institution that is situated next to a busy expressway, Mitigation measures include selection of quieter Air Handling Unit,
railway line, transit line, and/or airport. Indoor ambient noise is sound isolation box of a Fan Coil Unit, internally lined duct,
likely to be affected by traffic noise, train noise and/or air craft acoustics silencer, low noise air-grille and others.
noise. Provision of high airborne sound isolation performance
should be considered for facade glazing or external wall; apart On the other hand, smaller rooms such as class room, tutorial rooms
from setting building orientation and layout, as part of the effort and reading room could be utilising standalone system like ceiling
to keep external noise intrusion to a minimal. fan, stand fan, split-unit air conditioning unit and air cooler for
cooling. Special selection would then be required to ensure that
Ideally, noise crossover between rooms is to be kept minimal, or noise emission does not compromise the desired acoustics
at best none at all, in an effort to meet proposed ambient noise environment.
level and also to avoid annoyance.
Not withstanding to the ACMV system, the operations of electrical
It would be annoying if during a lecture the person could listen or mechanical products that emit noise and run for long periods of
to another lecture being conducted in the adjacent lecture time should also be reviewed when a certain ambient noise rating
theatre. Apart from being a nuisance, the crossover also disrupts needs to be achieved.
the teaching and learning process. Hence under such building
layout configurations, additional acoustics considerations, input,
design and construction effort would be required.
33
Ambient Noise Control Technical Manual
QUIET
ZONE
COMPUTER 4
ROOM
1 4 5
SEMINAR 2 1
ROOM
1 2
1 4
2 2
4 2
3 5
2
1
2 LECTURE
THEATRE
1
FOYER
TUTORIAL
ROOM
12.3 Lecture Hall and Auditorium The elements introduced could be absorptive, diffusive and/or
Lecture Hall or Auditorium typically is large volume room with mixed of the two. The common idea is to create a well distributed
rake floor design; which could cater to hundreds of audience. sound environment and at the same time with minimal sound
Due to its large space and crowd, modern day design also reverberation, echo and flutter. This will boost the audibility and
includes sound reinforcement system. speech intelligibility which further enhances the experience.
Elements such as acoustics absorptive wall panels with fabric and/or
With the presence of high delivery sound level and the large perforated timber finish, acoustics absorptive ceiling and carpet are
volume which encourages echoes and sound reverberations, typically seen as part of auditorium design.
interior acoustics treatment then becomes part and parcel of an
auditorium design. As speech intelligibility is critical in an auditorium and also in order
not to disturb adjacent teaching and learning facilities,
Common finishes includes plaster ceiling, profile ceiling with consideration on improving the sound isolation performance of the
acoustics treatment, acoustics absorptive and/or diffusive perimeter walls and doors would be essential.
panels; and some even come with carpet.
The following section proposed construction details and
recommendation on ACMV which serves as a guide in order to
meet desired ambient noise level as prescribed above.
34
Ambient Noise Control Technical Manual
2 Teaching and a a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro Wall to construct to full
Learning b) 100 mm thick clay brick height
b
Room c (min. density 1500 kg/cu.m)
- Lecture
Theatre, c) 100 mm thick clay brick
d (min. density 1500 kg/cu.m)
Seminar
Room e d) 20 mm thick plastering (on 3 sides)
e) 100 mm deep air cavity
3 Lecture a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro Wall to construct to full
Theatre, a b) 210 mm thick claybrick height
Seminar b (min. density 1500 kg/cu.m)
Room c c) 20 mm thick plastering (on 2 sides)
Suitable for Party Wall
d between 2 connecting
d) 2 x 16 mm thick Plasterboard Theatre or Auditorium
e (min. density 750 kg/cu.m)
e) 75 mm stud
4 Other a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro Wall to construct to full
Teaching height
a b) 2 x 16 mm thick Plasterboard
and Learning (min. density 750 kg/cu.m)
Rooms b For areas which requires
(Tutorial c) 2 x 16 mm thick Plasterboard frequent change of
c
Room, (min. density 750 kg/cu.m) space
Discussion d design or functions
d) 92 mm deep stud
Room)
35
Ambient Noise Control Technical Manual
36
Ambient Noise Control Technical Manual
* Door Solid wood core door with well-designed Bottom door seals will
door frame and ironmongery, with STC improve sound intrusion
rating 30-32. or sound leakage – best
introduce to critical rooms
2 hours fire rated doors with STC rating such as Lecture Theatre,
Auditorium, Seminar Rooms,
32-35. Meeting Rooms etc.
* Centralized Air Air Handling Unit/ To select fan with low noise unit as stated FCU may require acoustics
Conditioning Fan Coil Unit in laboratory testing (by manufacturer's box up if installed within
with delivery sensitive room or space
ducts testing)
Diffusers To select diffusers with low regeneration Noise will generate when
noise; especially for noise sensitive room excessive air and/or high
velocity air flows through
diffusers blades; hence the
selection
37
Ambient Noise Control Technical Manual
It is widely known that chaotic and high ambient noise Recommended Rating
Space / Room
environment would induce more stress to patients and does not NC Noise Level
help with the healing and recovery process. Furthermore under
Wards 30 - 35 35 - 40 dB(A)
such environment, medical consultation which emphasise on
speech intelligibility and privacy may be compromised as well. Consultation Room 35 - 40 40 - 45 dB(A)
38
Ambient Noise Control Technical Manual
13.2 Ambient Noise Level Consideration Well established healthcare centres are likely equipped with
Healthcare centres consider hygiene and bacteria/virus/allergen centralized ACMV system which typically allows noise mitigation to
free as of utmost importance. Hence, sterilisation is undertaken be introduced within the system to ensure resultant noise
every now and then, and at the same time healthcare centres do propagated would not compromise the desired ambient noise level.
not encourage the use of building elements that could
potentially be breeding grounds for such threats. Mitigation measures include selection of quieter Air Handling Unit,
sound isolation box of a Fan Coil Unit, internally lined duct,
Therefore, very often, general areas and medical treatment and acoustics silencer, low noise airgrille and others.
consultation related areas do not have any form of extra
acoustics treatment to it. Typically they are nice and flat surface. On the other hand, smaller establishments such as specialist clinic,
This also means healthcare centres are typically more general clinic, physiotherapist, could be utilising stand-alone system
reverberant. like ceiling fan, stand fan, split-unit air conditioning unit and air
cooler for cooling. Selection on quieter units would then be
For example a reverberant ward corridor or waiting area does required to ensure that noise emission does not compromise the
not have acoustic wall panels and are only mainly using acoustics desired acoustics environment.
rated ceiling panels.
Not withstanding the ACMV system, the operations of electrical,
Thus ambient noise level at various part of a healthcare centre mechanical and also medical equipment that emit noise and run for
could be different depending on the emphasis on providing long periods of time should also be reviewed when a certain
good sound isolation whether between the external and internal ambient noise rating needs to be achieved.
part of the building, wards, consultation rooms, treatment
rooms, operating theatres; and other such critical rooms as well
as other areas such as corridors, waiting areas, mechanical plant
room and so on.
39
Ambient Noise Control Technical Manual
5
SPECIALIST
CLINIC MEETING LOBBY 5
ROOM
4 5
RECEPTION CONSULTATION ROOMS
COUT ERS
5 2 2
CONSULTATION ROOMS
WALKWAY TREATMENT
ROOM
5
M&E ROOM
5
TREATMENT
ROOM
2
WAITING
AREA MACHANICAL
13.3 Patient Wards and Common Areas PLANT ROOM
3
As discussed in previous section, acoustics provision and
consideration for a healthcare centre is typically limited to WARD
providing good sound insulation performance for internal
partying elements and also building envelop against noise TOILET
intrusion; and noise mitigation of the ACMV system.
WARD
Interior acoustics elements such as acoustics absorptive panels,
diffusive panels and ceiling baffles are only limited to healthcare
centre that has auditorium or lecture hall.
Internal partitioning of a healthcare centre space is important as Due to the absence of acoustics absorption elements at most area
to provide speech privacy, minimise sound leakage, minimise of a healthcare centre, introduction of noise mitigation on
sound intrusion and ensuring certain ambient noise level could mechanical, electrical, ACMV and medical equipment which
be achieved. generates high noise level becomes important. Residual noise
energy could not be further absorbed and sound tends to have
Rooms such as patient wards, consultation rooms, operating longer decay time resulting in rooms and spaces being perceived to
theatres, surgical rooms, treatment rooms, and critical facilities be more reverberant.
are recommended to have partitioning elements with higher
sound isolation rating. However, other general and less critical The following section proposed construction details and
facilities could adopt a more common construction. recommendation on ACMV which serves as a guide in order to
meet the desired ambient noise level as prescribed above.
40
Ambient Noise Control Technical Manual
2 Consultation a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro Wall to construct to full
Rooms/ a b) 2 x 16 mm thick Plasterboard height
Wards
b (min. density 750 kg/cu.m) For areas which require
c c) 2 x 16 mm thick Plasterboard frequent change of
d (min. density 750 kg/cu.m) space design or
functions
d) 92 mm deep stud
3 Mechanical Perforated Panel Finish a) 50mm ROCKWOOL Safe 'n' Silent Pro Wall to construct to
Plant Room b) Perforated panel with minimum opening full height
Wall area of 15 - 20%
All round or all 4 sides of
a c) 20 mm thick plastering (both sides) the room should be full
b d) 210 mm thick clay brick height
c
d Wall choices to suit
requirements of building
fire codes and other
related installation
requirements.
4 Toilet Wall a) 50 mm thick ROCKWOOL Safe 'n' Silent Pro Wall to construct to
a b) 2 x 15 mm thick moisture resistance full height
b plasterboard (min. density 650 kg/cu.m)
c Wall choices to suit
c) 2 x 15 mm thick moisture resistance requirements in wet area
plasterboard (min. density 650 kg/cu.m) and other related
d) 92 mm deep stud installation requirements
such as wall tiling and
d penetrating services
41
Ambient Noise Control Technical Manual
6 Door Solid wood core door with well-designed Bottom door seals will improve
door frame and ironmongery sound intrusion or sound
leakage
2 hours fire rated doors – best introduce to critical
rooms
7 Centralized Air Handling Unit/ To select fan with low noise unit as stated FCU may require acoustics box
Air Fan Coil Unit in laboratory testing (by manufacturer's up if installed within sensitive
Conditioning testing) room or space
with delivery
ducts
Diffusers To select diffusers with low regeneration Noise will generate be when
noise; especially for noise sensitive room excessive air and/or high
velocity air flows through
diffusers blades; hence the
selection Air speed and volume
per diffuser are essential
42
Ambient Noise Control Technical Manual
14.0 ROCKWOOL
Safe ’n’ Silent
ROCKWOOL Safe ’n’ Silent is developed to form the mass interior designers, consultants, engineers and property owners;
spring-mass assembly of building elements that provides providing possible measures to achieve an optimal indoor acoustic
superior performance in building and room acoustics. By comfort for various environments. The manual does not limit itself
applying the suitable specifications of Safe ’n’ Silent Pro coupled to the listed recommendations, other design assemblies and
with building systems, the ambient noise level can be reduced construction details that are not listed may be acceptable through
according to recommendations hence giving better indoor the recommendations of ROCKWOOL representatives or acoustic
acoustic comfort. professionals before actual installation is being carried out. For
further information, kindly contact your local ROCKWOOL
The usage and application of Safe ’n’ Silent Pro is very wide, representatives for assistance.
ranging from drywall partitions and acoustic ceiling in residential
houses to workplaces such as offices, as well as wall lining With the unique and natural properties of ROCKWOOL
application specially for areas with concerns on reverberant Safe ’n’ Silent Pro, the product is safe and sustainable to use and no
noise. Its application provide a quieter environment by CFCs, HFCs, HCFCs or asbestos were used in its manufacture. It can
eliminating intrusion sound and background noise that causes be easily cut to size for a fast and simple installation between studs,
nuisance and discomfort to the occupants in a particular interior around electrical boxes, pipes, wiring, ductwork and even in drywall
space, thereby contributing to a better Noise Criteria (NC) partitions between studs and joists of non-standard widths.
rating. The ultimate aim is to give occupants better
concentration in places of study or work, better speech Safe ’n’ Silent Pro does not slump or sag when used in the wall
intelligibility, comfort in hearing and comprehending cavity, assuring there will be no gaps that may compromise the
conversations. performance of the system and providing lifetime protection against
noise and fire. The technical parameters and performance of
The Safe ’n’ Silent solutions in this manual are provided Safe ’n’ Silent Pro are given in Table 12.
as recommendations to building designers, architects,
Melting Point More than 1000°C More than 1000°C More than 1000°C ASTM E794
*Thermal Conductivity
0.036 0.035 0.034 ASTM C518
20°C λ Value (W/mK)
Water Absorption
1.0kg/m2 1.0kg/m2 1.0kg/m2 EN1609.97
(partial immersion)
ASTM C1104/
Water Vapor Absorption Less than 0.04 Vol % Less than 0.04 Vol % Less than 0.04 Vol %
C1104M
Thickness 50, 64, 75, 90mm 50, 64, 75, 90mm 50, 64, 75, 90mm EN822
Recommended for commercial Recommended for all drywall Recommended for drywall
Applications applications such as retail and partition applications with high acoustic insulation
office partition walls requirement
* Thermal conductivity values are based on testing conducted in external accredited laboratory in accordance to ASTM C518 : 1991.
Test reports are available upon request. For design, it is recommended to use a safety factor of 20% as design value.
43
ROCKWOOL IN ASIA
ROCKWOOL Asia shall provide no warranty on any of the performances of the recommendations stated in this manual.
outcome of the noise control. Therefore ROCKWOOL Asia shall not hold liability in the event of differences in actual application.
The installation of systems, use of space and occupancy within a space are subjected to changes that may influence the final
information available with regards to ambient noise control using ROCKWOOL Safe ’n’ Silent Pro in various system assemblies.
Disclaimer: ROCKWOOL Asia provides the information in this document with the considerations for the most accurate
T (+62) 21 2965 9071 Vietnam Representative Office
F (+62) 21 2953 8998 ROCKWOOL (Thailand) Limited
9th Floor, TNR Tower,
ROCKWOOL Malaysia Sdn Bhd 180-192 Nguyen Cong Tru Street,
Lot 4, Solok Waja 1 District 1, Ho Chi Minh City, Vietnam
Bukit Raja Industrial Estate T (+84) 8 6288 2009
41050 Klang, Selangor, Malaysia F (+84) 8 6288 4691
T (+60) 3 3341 3444
F (+60) 3 3342 7290
www.rockwoolasia.com