pH measurement
Measuring range: 0.00 to 14.00 pH
Resolution: 0.01 pH
Reference temperature: 25 °C
ORP measurement
Measuring range: -500 to +1500 mV
Resolution: 1 mV
Temperature compensations
automatic, according to:
- Nernst (for potable water and
wastewater)
- Nernst with non-linear solution
compensation (for high purity water)
- Nernst with linear compensation with
selectable coefficient (for high purity
water)
Sensor monitoring
Indication of glass breakage and line
disconnection.
Temperature measurement
with SWAN Pt1000 sensor.
Measuring range: -30 to +130 °C
Resolution: 0.1 °C Storage of event log, alarm log and cal- 2 Signal outputs (3rd optional)
ibration history. Two programmable signal outputs for
Sample flow measurement Storage of the last 1’500 data records measured values (freely scaleable, lin-
with digital sample flow meter. in logger with selectable time interval. ear or bilinear) or as continuous control
output (control parameters programma-
Real-time clock with calendar ble) as current source. 3rd signal output
Transmitter Specifications For action time stamp and preprogram- selectable as current source or current
and Functionality med actions. sink.
Current loop: 0/4 - 20 mA
Electronics case: Cast aluminum Safety features Maximum burden: 510
Protection degree: IP 66 / NEMA 4X No data loss after power failure, all data
Display: backlit LCD, 75 x 45 mm is saved in non-volatile memory. Control functions
Electrical connectors: screw clamps Overvoltage protection of in- and out- Relays or current outputs programma-
Dimensions: 180 x 140 x 70 mm puts. Galvanic separation of measuring ble for 1 or 2 pulse dosing pumps, so-
Weight: 1.5 kg inputs and signal outputs. lenoid valves or for one motor valve.
Ambient temperature: -10 to +50 °C Programmable P, PI, PID or PD control
Humidity: 10 - 90 % rel., non cond. Transmitter temperature monitoring parameters.
with programmable high/low alarm lim-
Power supply its. 1 Communication interface (option)
AC version: 100–240 VAC (±10 %), - RS485 interface (galvanically sepa-
50/60 Hz (±5 %) 1 Alarm relay rated) with Fieldbus protocol Modbus
DC version: 10–36 VDC One potential free contact for summary RTU or Profibus DP
Power consumption: max. 35 VA alarm indication for programmable - 3rd signal output
alarm values and instrument faults. - USB interface
Operation Maximum load: 1A / 250 VAC - HART interface
Easy operation based on separate
menus for “Messages”, “Diagnostics”, 1 Input
“Maintenance”, “Operation” and “Instal- One input for potential-free contact.
lation”. Programmable hold or remote off func-
tion.
User menus in English, German,
French and Spanish.
2 Relay outputs
Separate menu specific password pro- Two potential-free contacts program-
tection. mable as limit switches for measuring
Display of process value, sample flow, values, controllers or timer for system
alarm status and time during operation. cleaning with automatic hold function.
Max. load: 1A / 250 VAC