Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Khurram

Anchor Calculations 110


FS 2
Total 220
1.0 Strand Capacity

Dia. of Tendon Strand = 13.35 mm


Anchor Force Per meter, T = 220 kN/m

Spacing Between Anchors, l = 3m

Anchor Force, T = 660 kN

Factor of Safety for Tendon = 1.6

Specified Characteristics Strength of Anchor = 232 kN

Required No. of Strands = 5 No.

Actual No. of Strands = 5 No.

Load Per Strand = 132 kN/strand

2.0 Fixed Length Calculations

Grout/Tendon Interface

Ultimate Bond Stress for Clean Strands, sigma = 2 N/mm2

Factor of Safety of Grout/Tendon Interface = 2.5

Diameters of 5 No. Strands, d = 66.75 mm

Minimum Bond Length of Anchor, lb

Minimum Bond Length of Anchor 3.93 m


Grout/Ground Interface

Ultimate Bond Stress, Sigma sandy silt = 0.4 N/mm2

Factor of Safety of Grout/Ground Interface = 2.5

Diameter of Borehole = 120 mm

Minimum Bond Length of Anchor = 10.94 m

Maxiumum of (1) & (2) = 10.94 m

Adopted Bond Length of Anchor, lb = 11 m

3.0 Free Length Calculations

The minimum free length for rock and soil ground anchors is 4.5m for strand tandons.

Angle of Internal Friction = 30 Deg


0.5236 rad

Excavation Depth, H = 10 m

Anchor Depth = 2m

Anchor Inclination Angle, i = 15 Deg

d = 1m
Alpha = 30 deg
0.5236 rad

Minimum Free Length of Anchor, lf = 4.65874 m

Total Anchor length = 15.6587 m


= 16 m

You might also like