Compact Amplifiers

Controlled and uncontrolled


amplifiers for:
- trunk networks
- distribution networks
- active equalisation
- house connection

Trunk, distribution network, equaliser and


house

HFC 1
HFC Network Architectures

Overview 4

VGX distribution network amplifier 6


▪▪ VGX2143D-1G2 6

▪▪ VGX 242D-1G2 8

Controlled trunk / distribution network


amplifiers 12
▪▪ VGP3243D-1G2 12

▪▪ VGP2143D-1G2 14

Uncontrolled equaliser amplifiers 16


▪▪ VGE 1285-1G2 / VGE 12258-1G2 16

Our Company Our Products


The BKtel Group has its origin in the BKtel develops equipment and software
House connection amplifiers 18
foundation of BKtel communications in for FTTH and HFC broadband networks.
1997. The group was extended in 2002 The product portfolio includes a wide ▪▪ VOS 952-1G / VOS 953-1G 18
with BKtel systems (merged with BKtel range of products starting from equipment
communications in 2009), BKtel for optical transmission such as optical
components (2006), BKtel Photonics transmitters, amplifiers, and receivers and
Accessories 20
(2014) and BKtel networks in 2017. customer premises equipment, CATV ▪▪ Overview of accessoiries for the VGX distribution network amplifiers 20
Further international offices were founded headends, coaxial cable amplifiers. BKtel
in China and Japan for the growing Asian manufacturing facilities guarantee a high ▪▪ Overview of accessoiries for controlled trunk / distribution
market. The entire group has currently a quality standard (ISO 9001 certified). network amplifiers 21
workforce of over 130 employees Furthermore the company offers a
▪▪ Overview of plug-in diplex filter sets and accessoires for
worldwide, based in Germany in Hueckel- complete range of services such as
house connection amplifiers 22
hoven, (near Düsseldorf), in Rosenheim planning, installation and training.
(near Munich) and in Kornwestheim (near ▪▪ WiFi adapters, transponders 24
Stuttgart).
▪▪ Tap/splitter plug-in cards 25
The company develops and manufactures
products in the field of interactive FTTH-,
▪▪ Zero cards, equalisers 26

Video Overlay-, RFoG- and HFC-networks ▪▪ Connectors, plug-in diplex filters 28


for high performance data, telephone
and cable TV services. The high quality
products as well as the comprehensive Technical data 29
support in designing optical networks
make BKtel to one of the leading suppliers
Order number overview 41
in the FTTH and HFC market.

2 HFC HFC 3
Overview Compact Amplifiers

Additional properties for all VGPxxxD-1G2 "Plug-and-Play" redefined


▪▪ Frequency range 1006/1218 MHz switchable Electronic set-up of all significant parameters, automatic levelling
▪▪ The latest GaN technology (Second Generation) and option of remote configuration via HMS or DOCSIS moni-
▪▪ Power supply unit with power factor correction toring minimise commissioning and maintenance times. Thanks
to the copy function supported by the WTE 10, all settings can be
Additional properties VGP3243D-1G2 saved and transferred to other devices. As well as speeding up
▪▪ Two active outputs with configuration of up to 3 high levels commissioning on site, not having to use plug-in cards for
distribution outputs or one trunk output and up to two attenuation and slope simplifies logistics and reduces storage
distribution outputs (via internal output splitter field) costs.
▪▪ Gain and slope of the distribution network output can be set
separately Commissioning of uncontrolled amplifiers
without a meter – it couldn't be easier
Additional properties VGXxxxxD-1G2 The setting is made with the Wi-Fi adapter or an handheld
▪▪ Frequency range 1006 / 1218 MHz pluggable device. The Wi-Fi adapter provides a convenient means of
▪▪ The latest GaN technology (Second Generation) configuring the connected amplifier via a PC, tablet or smart-
▪▪ Power supply unit with power factor correction phone (a Web browser with active support for JavaScript is
▪▪ High gain (up to 46 dB uncontrolled) required). Thanks to automatic levelling, it takes only a few steps
General properties ▪▪ Loop-through output (VGX2143-1G2 only) to put the compact amplifiers into operation:
of compact amplifiers ▪▪ Simply enter the required output level for the upper and lower
Equaliser amplifier VGE 12xxx-1G2 pilot frequency and start the levelling process.
▪▪ Fixed gain and slope ▪▪ The device automatically sets itself to the required values in just
▪▪ Passive return path with 65 / 204 MHz a few seconds. The technical data is adjusted to the optimum
▪▪ Compact housing for easy retrofitting on the network settings. After this, manual fine adjustment is possible at any
time.
The compact amplifiers with electronic set-up ▪▪ Next, automatic pre-adjustment can be started on the return
▪▪ Modern compact amplifiers with monitoring capability for interactive HFC networks BKtel is delivering a compact amplifier class of the very latest path too.
▪▪ Innovative operating concept: Electronic actuators, set up via Wi-Fi module and handheld generation with its VGP product range, combining comprehen- ▪▪ Levelling takes even less time to complete on subsequent
device (settings can be saved in the Web browser and on PC/handheld device) sive setting options, electronic operation and outstanding devices. The copy function transfers the desired settings directly.
▪▪ Built-in (VGPxxxx) or optional (VGX xxx), frequency-agile 2-pilot control speeds up technical data with an unrivalled price-performance ratio.
commissioning:
• Automatic levelling on the forward path saves time-consuming manual calibration
• Return path can be pre-adjusted automatically
▪▪ Remote configuration of all tuning parameters supported by the monitoring system
(can be activated/deactivated)
▪▪ High gain (up to 46 dB uncontrolled), configurable interstage
▪▪ Very high output level with lowest intermodulation products even with interstage attenuation
▪▪ De-emphasis (inverse equalisation) insert position
▪▪ Remote feed capability at each input/output, local feed: 10 A
▪▪ Insert position for monitoring transponder
▪▪ Test sockets at input/output and in the return path amplifier
▪▪ Plug-in diplexers
▪▪ Built-in return path amplifier, adjustable gain
▪▪ Ingress control switch
▪▪ Die cast aluminium housing

4 HFC HFC 5
VGX distribution network amplifier

VGX distribution network amplifier

VGX2143D-1G2

The VGX2143D-1G2 is a distribution network amplifier can be configured using the WTE 10 Wi-Fi module together with
designed for current and future DOCSIS 3.1 HFC networks. a Web browser. The return path bandwidth is determined by the
The amplifier features up to two outputs and an additional plug-in diplex filter sets.
loop-through output. All electronic settings of the amplifier

13
3

2 Block diagram
8
7
1
6
5 Features
9 ▪▪ Modern compact amplifier for DOCSIS 3.1 HFC networks ▪▪ Insert position for TVM 500S FSK transponder
10 11
▪▪ Frequency range: up to 1218 MHz ▪▪ Test sockets at the input/output and in the return path
12
▪▪ High gain (up to 46 dB) amplifier
14
15 4
▪▪ Loop-through output, configurable via the input splitter ▪▪ Built-in return path amplifier, adjustable electronically
field "Loop-Through" ▪▪ Ingress control switch (ICS)
▪▪ Two distribution outputs, configurable via the output ▪▪ Die-cast aluminium housing with 5/8" connections
splitter field
▪▪ End stage in the latest GaN technology Note
Standard version: Modules for the following insert positions are not ▪▪ Innovative operating concept: Electronic actuators,
included in the product package: setting via a WTE 10 WiFi module During operation, an EBC/EAC xx must be plugged into

1 Connection socket for the handheld / WiFi module


▪▪ Optional ALSC module with frequency-agile 2-pilot the insert position at the output. Zero cards are already
8 Insert position for FSK multi-band transponder module
control speeds up commissioning plugged into the insert positions No. 2, 3, 4.

2 “Forward 1” insert position 9 Insert position for 2-pilot control module


• Automatic levelling on the forward path saves time-
consuming manual calibration
3 “Forward 2” insert position 10 Plug-in input diplex filter • Return path can be pre-adjusted automatically
▪▪ Very high output level with lowest intermodulation
4 “Return 1” and “Return 2” insert position 11 Plug-in output diplex filter products even with interstage attenuation
▪▪ Insert positions in the forward and return path
5 F test socket internal (-20 dB) output 12 Plug-in low-pass filter ▪▪ Remote feed capability: 10 A at each input/output For an overview of accessories, see page 20-28.

6 F test socket internal (-20 dB) input 13 Plug-in high-pass filter

7 “Hingepoint” insert position 14 Splitter field output

15 Splitter field input "Loop-Through"

6 HFC HFC 7
VGX distribution network amplifier

VGX distribution network amplifier VGX_242.pdf 1 09.05.2017 12:00:49

VGX 242D-1G2

The VGX 242D-1G2 is a distribution network amplifier tronic settings of the amplifier can be configured using the
designed for current and future DOCSIS 3.1 HFC net- WTE 10 Wi-Fi module together with a Web browser. The return
works. The amplifier features up to two outputs. All elec- path bandwidth is determined by the plug-in diplex filter sets.

13 3
8
2
7
1
Block diagram

9 5
6
10 11 Features
12 ▪▪ Modern compact amplifier for DOCSIS 3.1 HFC networks ▪▪ Test sockets at the input/output and in the return path
14 ▪▪ Frequency range: up to 1218 MHz amplifier
4
▪▪ High gain (up to 42 dB) ▪▪ Built-in return path amplifier, adjustable electronically
▪▪ Two distribution outputs, configurable via the output ▪▪ Ingress control switch (ICS)
splitter field ▪▪ Die-cast aluminium housing with 5/8" connections
▪▪ End stage in the latest GaN technology
▪▪ Innovative operating concept: Electronic actuators,
Standard version: Modules for the following insert positions are not setting via a WiFi module Note
included in the product package: ▪▪ Optional ALSC module with frequency-agile 2-pilot
control speeds up commissioning During operation, an EBC/EAC xx must be plugged into
1 Connection socket for the WTE 10 Wi-Fi adapter 8 Insert position for FSK multi-band transponder module • Automatic levelling on the forward path saves time- the insert position at the output. Zero cards are already
consuming manual calibration plugged into the insert positions No. 2, 3, 4.
2 “Forward 1” and JXP insert position 9 Insert position for 2-pilot control module • Return path can be pre-adjusted automatically
▪▪ Very high output level with lowest intermodulation
3 “Forward 2” insert position 10 Plug-in input diplex filter
products even with interstage attenuation

4 “Return 1” and JXP insert position


▪▪ JXP insert positions in the forward and return path
11 Plug-in output diplex filter
▪▪ Remote feed capability: 7 A at each input/output,
5 F test socket internal (-20 dB) output 12 Plug-in low-pass filter
▪▪ Insert position for TVM 500S FSK transponder For an overview of accessories, see page 20-28

6 F test socket internal (-20 dB) input 13 Plug-in high-pass filter

7 “Hingepoint” insert position 14 Splitter field output

8 HFC HFC 9
VGX distribution network amplifier

Additional properties of the VGXxxxxD-1G2 amplifiers in detail

1 Power supply unit 3 New modularity

tionary
Revolu
t
▪▪ State-of-the-art switched-mode power supply unit technology with very long concep
service life
▪▪ Active power factor correction with a factor of almost 1 1
▪▪ Improved dissipation of waste heat from the entire power supply unit thanks to
the heatsink coating. This results in a lower heat load in the device itself and
also helps to increase the maximum operating temperature range
▪▪ The power supply unit is easy to replace in the event of maintenance:
• Easily accessible plug-in contacts and screw connections
Function can be adjusted to suit requirements in a modular way
• No thermal pad required. This removes the need for positioning the pad and
eliminates the risk of losing it
▪▪ Insert position for 2-pilot control module. This enables cost-effective use of
the device for controlled and uncontrolled operation
3
2 Single-chamber shielding system ▪▪ FSK transponder insert position for TVM 500S for controlling the ICS switch
and for carrying out base unit updates remotely
▪▪ Customer-specific insert positions in the forward and return path enable
2 additional manual signal adjustment for built-in electronic set-up
▪▪ Insert position for operation in different frequency ranges (1.2 GHz/1 GHz)
(Hingepoint for 1.2 GHz pre-mounted)

Familiar modularity
▪▪ High mutual shielding between forward path, return path and other ▪▪ Customer-specific interstage forward insert position for plug-in cards such as
functional areas in the device. This prevents cross modulation and other system equalisers
unwanted coupling effects ▪▪ Plug-in diplexers for adjusting the frequency split of forward and return path
▪▪ Improved temperature discharge thanks to the built-in thermal dissipation ▪▪ Output insert field, individually configurable for one to two outputs with
domes on the bottom and top of the components. This results in a lower EBC/EAC xx-1G2 splitter or tap plug-in cards
heat load in the surrounding components and also helps to increase the ▪▪ Splitter field input (VGX2143D-1G2 only) for individual loop-through
maximum operating temperature range output configuration using EBC/EACxx-1G2 splitter and respectively tap
plug-in cards

10 HFC HFC 11
Controlled trunk / distribution network amplifiers

Controlled dual mode trunk / distribution amplifier


VGP 3243-1G2
AC

VGP3243D-1G2 TP OUT 1

Switched Mode Power Supply ALSC 2 Pilot / AGC / Controller

The VGP3243D-1G2 is a dual mode trunk / distribution net- bution network outputs. The output level of the amplifier are 2
dB HP OUT 1
work amplifier designed for current and future DOCSIS 3.1 HFC pilot controlled. All amplifier settings are made electronically using
LP
networks. Two active output stages can be configured for up to 3 the handheld or Wi-Fi module with a Web browser.
Plug In Plug In TP OUT 2
high level distribution network or 1 trunk level and up to 2 distri- Position dB HP dB Position

TP IN
OUT 2

IN HP Docsis/HMS/FSK Transponder HP
OUT 3
LP LP

dB ICS
Plug In
Position dB LP dB
8
1 dB ICS Ingress
Test

Block diagram

3
11
Features
2
▪▪ Modern controlled amplifier with remote monitoring for ▪▪ Insert position for monitoring transpoder
6 5 DOCSIS 3.1 HFC networks (FSK/HMS/DOCSIS)
4
9 9 ▪▪ Frequency range: up to 1218 MHz ▪▪ Test sockets at the input/output and in the return path
10 (selectable between 1006 MHz and 1218 MHz) amplifier
12 ▪▪ Configuration of up to 3 high level distribution or 1 trunk ▪▪ Built in return path amplifier, adjustable electronically
level and up to 2 distribution network outputs ▪▪ Ingress control switches (ICS)
▪▪ GaN second generation 2 active outputs amplifier ▪▪ Die cast aluminum housing with PG 11 connections
7 ▪▪ Innovative operating concept: Electronic actuators setting
by Wi-Fi module (minimizing plug in cards and attenua-
Standard version: Modules for the following insert positions are not tion pads. Exactly readable and reproducible settings)
included in the product package: ▪▪ Built in frequency agile 2 pilot control speeds up com- Note
missioning:
1 Connection socket for handheld / Wi-Fi adapter 8 Insert position for monitoring transponder module • Automatic levelling on the forward path saves time During operation, an EBC/EAC xx must be plugged into
consuming manual setting the output splitter field. Pass through cards are already
2 “Forward 1” insert position 9 Plug-in output diplex filter • Return path can be adjusted automatically plugged into the insert positions no. 2 and 3. The optional
▪▪ Remote configuration of all tuning parameters supported HMS monitoring transponder TVM 850 can only be used
3 “Forward 2” insert position 10 Plug-in input diplex filter
by monitoring system (can be deactivated) up to a maximum return path frequency of 65 MHz.

4 Plug in low pass filter “TP Return Path” 11 Plug-in high pass filter “HP Forward Path”
▪▪ Very high output level (115 dBµV) with very low inter-
modulation products even with interstage attenuation
5 F test socket internal (-20 dB) output 12 Splitter field output (splitters, taps) ▪▪ Remote feed capability: Up to 10 A at each input/
output, local feed: 10 A For an overview of accessories, see page 20-28.
6 F test socket internal (-20 dB) input

7 Ingress test point external

12 HFC HFC 13
Controlled trunk / distribution network amplifiers

VGP2143D-1G2

The VGP 2143D-1G2 is a distribution network amplifier All amplifier settings are made electronically using the handheld
designed for current and future DOCSIS 3.1 HFC networks. or Wi-Fi module with a Web browser. The return path bandwidth
One active output stage can be configured for up to 2 high is determined by various plug in diplex filter sets.
level distribution network outputs.

8 1

Block diagram
3
11

6 5 Features
4
9 ▪▪ Modern controlled amplifier with remote monitoring for ▪▪ Insert position for monitoring transpoder
10 DOCSIS 3.1 HFC networks (FSK/HMS/DOCSIS)
12 ▪▪ Frequency range: up to 1218 MHz (selectable between ▪▪ Test sockets at the input/output and in the return path
1006 MHz and 1218 MHz) amplifier
▪▪ Configuration of up to 1 distribution network outputs ▪▪ Built in return path amplifier, adjustable electronically
7 ▪▪ High gain: up to 43 dB controlled ▪▪ Ingress control switches (ICS)
▪▪ GaN second generation 1 active output amplifier ▪▪ Die cast aluminum housing with PG 11 connections
Standard version: Modules for the following insert positions are not
▪▪ Innovative operating concept: Electronic actuators setting
by Wi-Fi module (minimizing plug in cards and attenua-
included in the product package: Note
tion pads. Exactly readable and reproducible settings)
1 Connection socket for the WTE 10 Wi-Fi adapter 8 Insert position for monitoring transponder module ▪▪ Built in frequency agile 2 pilot control speeds up During operation, an EBC/EAC xx must be plugged into
commissioning: the output splitter field. Pass through cards are already
2 “Forward 1” insert position 9 Plug-in output diplex filter • Automatic levelling on the forward path saves time plugged into the insert positions no. 2 and 3. The optional
consuming manual setting HMS monitoring transponder TVM 850 can only be used
3 “Forward 2” insert position 10 Plug-in input diplex filter • Return path can be adjusted automatically up to a maximum return path frequency of 65 MHz.
▪▪ Remote configuration of all tuning parameters supported
4 Plug in low pass filter “TP Return Path” 11 Plug-in high pass filter “HP Forward Path” by monitoring system (can be deactivated)
▪▪ Very high output level (115 dBµV) with very low inter-
5 F test socket internal (-20 dB) output 12 Splitter field output (splitters, taps) modulation products even with interstage attenuation
▪▪ Remote feed capability: Up to 10A at each input/output,
6 F test socket internal (-20 dB) input local feed: 10 A For an overview of accessories, see page 20-28.

7 Ingress test point external

14 HFC HFC 15
Uncontrolled equaliser amplifiers

VGE 1285-1G2 / VGE 12258-1G2

The VGE equaliser amplifier is ideal for supplementary compen- it offers an plug-and-play solution that is easy to install. The
sation of cable attenuation in the case of a network upgrade. return path, which goes from 5 to 65 MHz or 5 to 204 MHz
respectively, is passive with a low attenuation of max. 2.5 dB.
The forward range starts at 85 MHz or 258 MHz respectively and Power can be supplied to the amplifier by connecting a remote
goes up to 1218 MHz. A slope of 10 dB or 11 dB respectively on feed to the input or output. The input or output can also be used
the upstream cable network resulting from long cable lengths is to supply looped-through remote feed currents up to 7 A to the
compensated. As the amplifier requires no manual set-up, upstream or downstream amplifiers.

VGE 1285-1G2 block diagram

Features VGE 1285-1G2 Common features


· Forward path frequency range: 85-1218 MHz ▪▪ Low return loss of 2.5 dB
· Forward path gain of 12 dB/10 dB pre-emphasis ▪▪ Input and output can be fed remotely
· Return path frequency range: 5-65 MHz ▪▪ High screening factor - class A
▪▪ High corrosion resistance
Features VGE 12258-1G2 ▪▪ Protection class: IP 65 ¹)
· Forward path frequency range: 258-1218 MHz ▪▪ Simple installation
· Forward path gain of 12,5 dB/ 11 dB pre-emphasis ▪▪ Connections: 5/8"-24 (socket)
Actual product not shown · Return path frequency range: 5-204 MHz ▪▪ Optional mounting plate ZMP 200
for wall mounting

¹) Providing a suitable plug is used

For an overview of accessories, see page 20-28.

16 HFC HFC 17
House connection amplifiers

House connection amplifiers


VOS 952-1G / VOS 953-1G Return path Return path
De-emphasis
Return path Return path

The compact and very reasonably priced VOS 952-1G and VOS particular note include the high dynamic range during interstage Pre-emphasis Attenuation Pre-emphasis Attenuation

953-1G house connection amplifiers have been designed for use operation and a money-saving operating concept with slide Current
Temperature

in modern HFC networks. Features of its design worthy of switches. Operating voltage

Monitoring transponder

passive passive

active active

3 8

1 2
9 Pre-emphasis Attenuation
Attenuation

2 "switched off"
Ingress detection
two-way
Pre-emphasis
internal
switched off
Return path
3 two-way

Output
8
Input

F connector F connector = slide switch F connector F connector

(Return path:

5
Block diagram

3
7

Features
▪▪ Monitorable house connection amplifiers for modern ▪▪ Directional coupler test socket at the amplifier output
6 4 HFC networks and on the return path
▪▪ The latest GaAs-MMIC technology ▪▪ Feature for injecting test signals for the return path
Standard version: Modules for the following insert positions are not included in
▪▪ Innovative operating concept: ▪▪ Highly efficient switched mode power supply unit
the product package:
• Set-up via slide switches ▪▪ VOS 952-1G - local feed, F sockets
• Exactly reproducible device settings ▪▪ VOS 953-1G - remote feed (for auto-supply), F sockets
1 LED (power supply function) 8 Input insert position e.g. for de-emphasis equaliser • Fewer plug-in cards and attenuation pads required ▪▪ Voltage surge conductors on all RF connections and in
▪▪ Very high output level with very low intermodulation the switched mode power supply unit
2 Forward path: attenuation and equalisation are 9 Insert position for the monitoring transponder products ▪▪ Die-cast housing
set with slide switches ▪▪ Built-in active and passive return path with numerous ▪▪ Test sockets: F sockets
setting options
3 Built-in return path amplifier can be adjusted with
▪▪ 1-band operation available, requires no return path
slide switches
▪▪ 15 MHz high-pass filter can be activated on the return
path
4 F test socket at the output for return path
measurement or feed (-20 dB)
▪▪ Ingress control switch (ICS)
▪▪ HMS or DOCSIS monitorable (option)
5 Return path can be switched between passive/active ▪▪ Insert position for additional functions on the forward
path (e.g. de-emphasis)
6 F test socket for the return path (-10 dB) ▪▪ Two-way test socket at the amplifier input with inductive For an overview of accessories, see page 20-28.
decoupling
7 Two-way F test socket at the input (-20 dB)

18 HFC HFC 19
Accessories

Accessories

Overview of accessories for the VGX distribution network amplifiers Overview of accessories for controlled trunk / distribution network amplifiers

Description Type Order no. VGX xxxxD-1G2 Description Type Order no. VGP xxxxD-1G2

Zero card for operation with one output 1.2 GHz EBC 00-1G2 24510217  Zero card for operation with one output 1.2 GHz EBC 00-1G2 24510217 

Splitter (two symmetrical outputs) 1.2 GHz EBC 90-1G2 24510214  Splitter (two symmetrical outputs) 1.2 GHz EBC 90-1G2 24510214 

Tap (3/6 dB) 1.2 GHz EAC 93-1G2 24510216  Tap (3/6 dB) 1.2 GHz EAC 93-1G2 24510216 

Tap (1.5/10 dB) 1.2 GHz EAC 90-1G2 24510215  Tap (1.5/10 dB) 1.2 GHz EAC 90-1G2 24510215 

Tap (0.8/20 dB) 1.2 GHz EAC 94-1G2 24510220  Tap (0.8/20 dB) 1.2 GHz EAC 94-1G2 24510220 

FSK multi-band transponder module TVM 500 26210846 - FSK multi-band transponder module TVM 500 26210846 

FSK multi-band transponder module, small TVM 500S 26210868  FSK multi-band transponder module, small TVM 500S 26210868 -

DOCSIS monitoring transponder TVM 1000 26210086 - DOCSIS monitoring transponder TVM 1000 26210086 

WiFi module for wireless setting via a Webbrowser WTE 10 25010086  WiFi module for wireless via a Webbrowser WTE 10 25010086 

Automativ level and slope control module ALSCM 10 24510232  Adapter ring PG 11 to 5/8" EMU 29 273243 

PG 11 to 3.5/12 connector (female) EMP 53 25010011 - Adapter PG 11 to 3.5/12 socket EMP 53 25010011 

PG 11 to IEC connector (female) with M14 male thread EMP 34 275289 - PG 11 to IEC connector (f) with M14 male thread EMP 34 275289 

5 / 8" to F connector (female) EMP 51 275351  PG 11 to F-socket (female) EMP 35 275300 

Plug-in diplex filter sets Plug-in diplex filter sets

Diplexer 65/85 MHz WFS 906-1G2 24510218  Diplexer 65/85 MHz WFS 906-1G2 24510218 

Forward path equaliser 85 MHz ERS 9085-1G2 24510219  Forward path equaliser 85 MHz ERS 9085-1G2 24510219 

Return path equaliser 65 MHz ERR 9065 24510156  Return path equaliser 65 MHz ERR 9065 24510156 

Diplexer 85/105 MHz WFS 908-1G2 24510222  Diplexer 85/105 MHz WFS 908-1G2 24510222 

Forward path equaliser 105 MHz ERS 9105-1G2 24510223  Forward path equaliser 105 MHz ERS 9105-1G2 24510223 

Return path equaliser 85 MHz ERR 9085 24510158  Return path equaliser 85 MHz ERR 9085 24510158 

Diplexer 204/258 MHz WFS 920-1G2 24510209  Diplexer 204/258 MHz WFS 920-1G2 24510209 

Forward path equaliser 258 MHz ERS 9258-1G2 24510210  Forward path equaliser 258 MHz ERS 9258-1G2 24510210 

 See additional data on the next page

20 HFC HFC 21
Accessories

Overview of plug-in diplex filter sets Description Type Order no. VOS 952-1G VOS 953-1G

Return / Forward De-emphasis equaliser, switchable,


Type Order no. VGXxxxxD-1G2 VGP2143D-1G2 VGP3243D-1G2 ERD 810 24510110  
Frequency
862 MHz
65 / 85 MHz WFS 906-1G2 24510218 2 2 3
De-emphasis cable equivalent 7 dB,
ERZ 940 24510059  
ERS 9085-1G2 24510219 1 1 1 862 MHz

ERR 9065 24510156 1 1 1  e-emphasis cable equivalent 7 dB,


D
ERD 813 24510117  
based on 85-862 MHz, 1 GHz
85 / 105 MHz WFS 908-1G2 24510222 2 2 3
Attenuation pad 6 dB, 1 GHz ERD 814 24510120  
ERS 9105-1G2 24510223 1 1 1
Attenuation pad 10 dB, 1 GHz ERD 815 24510127  
ERR 9085 24510158 1 1 1
Adapter ring PG 11 to 5/8" EMU 29 273243 - -
204 / 258 MHz WFS 920-1G2 24510209 2 2 3
Adapter PG 11 to 3.5/12 socket EMP 53 25010011 - -
ERS 9258-1G2 24510210 1 1 1
PG 11 to IEC connector (f) with M14
ERR 9204 24510211 1 1 1 EMP 34 275289 - -
male thread
The table shows the number of plug in modules for full configuration of each amplifier type. PG 11 to F-socket (female) EMP 35 275300 - -

Plug-in diplexer sets

Diplexer 65/85 MHz WFS 906-1G2 24510218 - -


Overview of accessories for house connection amplifiers
Forward path equaliser 85 MHz ERS 9085-1G2 24510219 - -

Description Type Order no. VOS 952-1G VOS 953-1G Return path equaliser 65 MHz ERR 9065 24510156 - -

Diplexer 85/105 MHz WFS 908-1G2 24510222 - -


Splitter (two symmetrical outputs) EBC 90-1G 24510113 - -
Forward path equaliser 105 MHz ERS 9105-1G2 24510223 - -
Tap (3/6 dB) EAC 93-1G 24510115 - -
Return path equaliser 85 MHz ERR 9085 24510158 - -
Tap (1.5/10 dB) EAC 90-1G 24510116 - -
Diplexer 204/258 MHz WFS 920-1G2 24510209 - -
Tap (0.8/20 dB) EAC 94-1G 24510114 - -
Forward path equaliser 258 MHz ERS 9258-1G2 24510210 - -
Tap 2/6 dB, 3 dB de-emphasis ERP 101 24510128 - -
Return path equaliser 204 MHz ERR 9204 24510211 - -
FSK multi-band transponder module TVM 500 26210846 - -

FSK multi-band transponder module, TVM 500S 26210868


- -
small

DOCSIS monitoring transponder TVM 1000 26210086  

Equaliser 47-630 MHz, can be adjusted


ERZ 630 24510108  
from 2-18 dB in 2 dB steps

System equaliser 862 MHz ERS 800 24510109 

22 HFC HFC 23
Accessories

Robust Handheld FSK multi-band transponder module


HTE 20* TVM 500/TVM 500 S
The HTE 20* can be connected to amplifiers and fiber nodes for configuration of these ▪▪ FSK transponder for compact and house connection amplifiers and also optical
host devices using a data cable. This new handheld is the successor of the HTE10 and compact receivers (see page 44)
inherits the possibility to control also the devices supported by the HTE10. The HTE 20* ▪▪ Control of the ingress control switch in devices that are equipped with this facility
handheld is conveniently powered by the controlled device (plug-and-play connection). ▪▪ Robust Frequency Shift Keying (FSK) modulation
▪▪ Frequency-agile in selected frequency ranges
Features
▪▪ Display of all device settings on the integrated display.
▪▪ Ambient conditions:
• Operating temperature: -20 to +50°C DOCSIS/Euro-DOCSIS 2.0 monitoring transponder,
• Suitable for outdoor use
frequency-agile
• Housing protection class: IP 54
▪▪ Language: English
TVM 1000
▪▪ Copy function for saving the device settings ▪▪ Monitoring transponder for amplifiers and optical compact receivers (see table on
▪▪ No additional power supply necessary page 44)
▪▪ Software can be updated in order to support new devices and functions ▪▪ Monitoring of various parameters such as voltage, current consumption, internal
▪▪ Very fast start up time * Available in Q1 / 2019 temperature, etc.
▪▪ Transmission in DOCSIS or EuroDOCSIS protocol
▪▪ 10/100 BaseT service interface
▪▪ Frequency-agile in the range 5-65/90-862 MHz
WiFi module ▪▪ Additional monitoring functions
WTE 10

The WTE 10 WiFi moduleallows connected amplifiers and fibre nodes to be accessed Tap/splitter plug-in cards
conveniently from a PC, tablet or smartphone for configuration purposes. To view the
EAC 90-1G2, EAC 93-1G2, EAC 94-1G2, EBC 90-1G2
configuration, only a Web browser supporting JavaScript is required. The WTE 10 Wi-Fi
module simply has to be connected to the controlling device (plug-and-play connection); ▪▪ Plug-in modules to expand the corresponding device to two outputs
it draws its power supply from the controlling device. ▪▪ Can be used in the splitter field loop-through input
▪▪ Suitable for amplifiers and fibre nodes
Actual product not shown
Features
▪▪ WiFi standard to IEEE 802.11 b/g/n
▪▪ Display of all device settings via a Web interface
▪▪ Ambient conditions: Tap/splitter plug-in cards
• Operating temperature: -20 to +50°C
EAC 90-1G, EAC 93-1G, EAC 94-1G, EBC 90-1G
• Suitable for outdoor use
• Housing protection class: IP 54 ▪▪ Plug-in modules to expand the corresponding device to two outputs
▪▪ Language: English ▪▪ Can also be used in the splitter field loop-through input depending on device type
▪▪ Copy function for saving the device settings ▪▪ Suitable for amplifiers and legacy 1 GHz fiber nodes
▪▪ No additional power supply necessary
▪▪ Can be updated in order to support new devices and functions Actual product not shown

24 HFC HFC 25
Accessories

Zero cards System equaliser Prinzipieller Frequenzverlauf ERS 800

0 47 100 200 300


MHz
400 500 600 700 800 862

EBC 01E-1G, EBC 00-1G2 ERS 800


0
1

3
dB
4

Features Features 5

▪▪ Plug-in modules for trough connection e.g. for operation with one output ▪▪ System equaliser for use in special application cases 7

▪▪ Characteristic: Cable-equivalent pre-emphasis in range 47-700 MHz:


Actual product not shown 3 dB (equivalent in range 47-862 MHz: 4 dB)
▪▪ Cable-equivalent pre-emphasis in range 700-862 MHz:
3 dB (equivalent to increase of 2 dB in range 700-862 MHz)
C-line pre-emphasis equaliser ▪▪ Suitable for compact amplifiers and compact fiber nodes
ERC 22

Features
▪▪ Creates a pre-emphasis based on the C-line specification for german networks
▪▪ For use in the universal input insert position (“Forward 1”) De-emphasis equaliser/attenuation attachment
ERD 813, ERD 814, ERD 815, ERP 101

Equalisers and attenuation pads


De-emphasis equaliser
ERZ 940 Features
▪▪ Available types:
Features • ERD 813: Cable-equivalent de-emphasis 7 dB ¹)
▪▪ Cable simulation, 7 dB • ERD 814: 6 dB attenuation ¹)
▪▪ 7 dB de-emphasis equaliser for VOS 95x and VGP 95x • ERD 815: 10 dB attenuation ¹)
▪▪ ERP 101: Tap 2/6 dB, de-emphasis 3 dB ¹)
▪▪ Suitable for amplifiers and fiber nodes
Equaliser, 630 MHz
ERZ 630 ¹) Based on 862 MHz

Features
▪▪ Equaliser, 47-630 MHz
▪▪ Adjustable from 2-18 dB in 2 dB steps (cable equivalent)
▪▪ For use in the input insert position of the VOS 95x and other amplifiers

26 HFC HFC 27
Accessories Technical data

Connectors as options for die cast housings Technical data


EMP 34, EMP 35, EMU 29
Transitions: VGX distribution network amplifier
EMP 34
▪▪ EMP 34 (BN 275289): PG 11 to IEC connector (female)
▪▪ EMP 35 (BN 275300): PG 11 to F connector (female) Type VGX 242D-1G2 VGX2143D-1G2 Comments
▪▪ EMP 53 (BN 25010011): PG 11 to 3.5 / 12 connector (female)
▪▪ EMU 29 (BN 273243): Adapter ring PG 11 to 5/8" Order no. 24410188 690019-xx
▪▪ EMP 51 (BN 275351): 5/8" to F connector (female) EMP 35 Forward path

Number of outputs 1 or 2

Loop-through output No Yes

Frequency range [MHz] 85-1006/1218


EMU 29
Gain (at 1218 MHz) uncontrolled/controlled with ALSC 42/37 46/43
module ALSCM 10 [dB]
Plug-in diplex filters
Gain variation, uncontrolled/controlled [dB] ± 1.5/0.8
WFS 906-1G2, ERS 9085-1G2, ERR 9065
Return loss [dB] 18 -1.5 dB/oct. (min. 13)
WFS 908-1G2, ERS 9105-1G2, ERR 9085
WFS 920-1G2, ERS 9258-1G2, ERR 9204 Frequency response (85-1218 MHz at 25°C) [dB] ± 0.5

Frequency response additional [dB] ± 0.8


Diplex filters and return path system equalisers for bandwidth selection.
Attenuation range by electronical setting [dB] 0-20
▪▪ Components for frequency split 65/85 MHz: Interstage attenuation range [dB] 0-20
WFS 906-1G2: Input and output diplexer 65/85 MHz
Slope range by electronical setting [dB] 0-18
ERS 9085-1G2: Interstage downstream equaliser (downstream from 85 MHz)
ERR 9065 return path system equaliser (upstream up to 65 MHz) Pre-emphasis range by elecronical setting [dB] 0-18
▪▪ Components for frequency split 85/105 MHz: Noise figure [dB] 7
WFS 908-1G2: Input and output diplexer 85/105 MHz
Automatic slope control range [dB] ±2
ERS 9105-1G2: Interstage downstream equaliser (downstream from 105 MHz)
Automatic gain control range [dB] ±3
ERR 9085: Return path system equaliser (upstream up to 85 MHz)
▪▪ Components for frequency split 204/258 MHz: Max. input level [dBµV] 85
WFS 920-1G2: Input and output diplexer 204/258 MHz Maximum output level BER 10^-9, 110 QAM 256,
109 111
ERS 9258-1G2: Interstage downstream equaliser (downstream from 258 MHz) 258-1218 MHz, 10 dB slope [dBµV]
ERR 9204: Return path system equaliser (upstream up to 204 MHz)
Hum modulation [dB] 70

Spurious (> 85 MHz) [dBµV] 15

Return path

With WFS 9065/


Frequency range [MHz] 5-65/5-85/5-204 WFS 9085/WFS
9204

With WFS 9065/


Gain [dB] 28/29/33 WFS 9085/WFS
9204

Amplitude response 5-204 MHz, at 25°C [dB] ± 0.5

 See additional data on the next page

28 HFC HFC 29
Technical data

Type VGX 242D-1G2 VGX2143D-1G2 Comments


Controlled compact amplifiers

Additional amplitude response over attenuation, slope and Type VGP3243D-1G2 Comments
± 0.4
temperature [dB]

Input noise density (CINR = 50 dB, 25 dB gain flat) Order no. 690018-xx
-9
[dBµV / Hz] Forward path
Dynamic range: CINR > 50 dB, 5-65 MHz, 25 dB gain Modes Trunk Distribution network
25
[dB]
Number of trunk outputs 1 0
Depending on
Attenuation range, electronically adjustable [dB] 5 – 30 / 4 – 30 / 0 - 30 Diplex filter set Number of distribution outputs 1 or 2 2 or 3
(65/85/204 MHz) Frequency range [MHz]; upper limit selectable 85 – 1006 / 1218
Depending on Gain (at 1218 MHz) uncontrolled / controlled [dB] 40 / 37 46 / 43
Slope range, electronically adjustable [dB] 0.4 – 7.5 / 0.8 – 9 / 1 - 14 Diplex filter set
(65/85/204 MHz) Return loss [dB] 18 – 1.5 dB / oct. (min.13)

ICS attenuation (can be switched via EMS or WiFi module) Frequency response (85 – 1218 MHz at 25°C) [dB] ± 0.5
0/6/> 45
[dB] Frequency response additional [dB] ± 0.8
Hum modulation at 7A (>15 MHz) [dB] 70 Maximum input level [dBµV] 85
Spurious (> 15 MHz) [dBµV] < 15 Maximum operation output level [dBµV] 115
General CSO at 43dB gain, 10 dB slope at 1.2GHz, [dB] 70 67
Impedance [Ω] 75 CENELEC 41 carriers, level at 862MHz [dBµV] 106 112

AC supply voltage including tolerances [V] 30-90 CTB at 43dB gain, 10 dB slope at 1.2GHz, [dB] 75 70
CENELEC 41 carriers, level at 862MHz [dBµV] 106 112
Power consumption (High/Low Mode) [W] 20/17 21/18

Max. remote feed current per connection [A] 7 Attenuation range, electronically adjustable [dB] 0 – 16

RF input and output connections 5


/8"
Slope range, electronically adjustable [dB] 1006 / 1218 MHz 0 – 13 / 15
Housing protection class IP 54 (IP65 on request)
Interstage pre-emphasis range [dB] 1006 – 1218 MHz 0 – 15 / 17
Ambient temperature range (in operation, compliant with
-20 to 60 Noise figure [dB] 8
specified data) [°C]

Screening factor Class A Automatic slope control range [dB] ±2

Over voltage protection 6 kV; 1.2/50 µs, (IEC 60-2) Automatic gain control range [dB] ±3

Dimensions (W × H × D) [mm] 250 × 201 × 95 Frequency range of lower pilot Pu (PAL/CW/QAM) MHz 1) 120 - 450

Frequency range of upper pilot Po (PAL/CW/QAM) MHz 1) 420 - 998


All data listed are typical values unless indicated otherwise.
Output level, BER 10^ -9, 110ch. 256QAM,
111
258 – 1218 MHz, 10 dB slope [dBµV]

Pilot carrier level range (PAL/CW/QAM) [dBµV] 83 - 112 87 - 114

Hum modulation ratio at 7 A [dB] 70

 See additional data on the next page

30 HFC HFC 31
Technical data

Type VGP3243D-1G2 Comments Type VGP2143D-1G2 Comments

Spurious [dBµV] < 15 Order no. 690017-xx

Return path Forward path


With WFS 906 / 908 Number of outputs 1 or 2
Frequency range [MHz] 5 – 65 / 85 / 204
/ 920
Frequency range [MHz]; upper limit selectable 85 – 1006 / 1218
Gain for return path 65 / 85 / 204 MHz [dB] 28 / 29 / 33
Gain (at 1218 MHz) uncontrolled / controlled [dB] 46 / 43
Frequency response 8 – 204 MHz [dB] ± 0.35
Gain variation ALSC off, -10°C … +55°C [dB] ± 1.2
Depending on
Attenuation range, electronically adjustable [dB] 5 – 30 / 4 – 30 / 0 - 30 Diplex filter set Return loss [dB] 18 – 1.5 dB / oct. (min.13)
(65/85/204 MHz) Frequency response (85 – 1218 MHz at 25°C) [dB] ± 0.5
Depending on Frequency response additional [dB] ± 0.8
Slope range, electronically adjustable [dB] 0.4 – 8 / 0.8 – 9.5 / 1 – 15 Diplex filter set
(65/85/204 MHz) Maximum input level [dBµV] 85

Return loss 8- 65 / 85 / 204 MHz [dB] 19 Maximum operating level [dBµV] 115

ICS attenuation (can be switched via EMS or Wi-Fi module) CSO ratio, 1 x 106 dBµV [dB] 1)
67
0 / 6 / >45
[dB]
CTB ratio, 1 x 106 dBµV [dB] 1) 70
Hum modulation at 7A (>15 MHz) [dB] > 70
Attenuation range, electronically adjustable [dB] 0 – 16
Test point [dB] 0
Slope range, electronically adjustable [dB] 1006 / 1218 MHz 0-13 / 15
General data
Interstage pre-emphasis range [dB] 1006 / 1218 MHz 0 – 15 / 17
Impedance [Ω] 75
Noise figure [dB] 8
Nominal supply voltage range, sine wave [VAC] 28 – 65
Automatic slope control range [dB] ±2
Power consumption without transponder [W] 42
Automatic gain control range [dB] ±3
Max. remote feed current, local injection [A] 10
Max. remote feed current, normal operation per Frequency range of lower pilot Pu (PAL/CW/QAM) MHz 2) 120 - 450
10
RF port [A]
Frequency range of upper pilot Po (PAL/CW/QAM) MHz 2) 420 - 998
RF input and output interfaces 4 x PG11
Output level, BER 10^ -9, 110ch. 256QAM,
Protection class acc. to DIN EN 60529 IP 54 111
258 – 1218 MHz, 10 dB slope [dBµV]
Ambient temperature range (in operation, compliant with
-25 to +60 Pilot carrier level range (PAL/CW/QAM) [dBµV] 87 -114
specified data) [°C]
Over voltage protection 6kV; 1.2/50µs, (IEC 60-2) Hum modulation [dB] 70

Housing material Aluminum die cast Spurious (> 85 MHz) [dBµV] < 15

Dimesions (W x H x D) [mm] 2) 240 x 115 x 240


Network management (optional)

Remote feed voltage, secondary current, supply voltage booster


amplifier, temperature, electronic tuning element values, pilot
Parameters for remote management and configuration settings and alarms, automatic levelling, summer / winter offset,
ICS, remote inventory date, downstream frequency range, diplex
filter set

¹) Setting via handheld / Wi-Fi module. Min. ratio between pilot frequency Pu and Po 250 MHz
²) Width incl. lid hinges: 267 mm
 See additional data on the next page
All data are typical values unless indicated otherwise.

32 HFC HFC 33
Technical data

Type VGP2143D-1G2 Comments Type VGE 1285-1G2 VGE 12258-1G2

Return path Order no. 24410145 24410184


With WFS 906 Forward path
Frequency range [MHz] 5 – 65 / 85 / 204
/908 / 920
Frequency range [MHz] 85-1218 258-1218
Gain for return path 65 / 85 / 204 MHz [dB] 28 / 29 / 33
Gain (at 1218 MHz) ± 0.5 dB [dB] 12 12,5
Frequency response 8 – 204 MHz [dB] ± 0.35
Return loss, at and above 40 MHz [dB] 18 -1.5 dB/oct. min. 13 dB
Depending on
Attenuation range, electronically adjustable [dB] 5 – 30 / 4 – 30 / 0 - 30 Diplex filter set Frequency response (85-1218 MHz at 25°C) [dB] ± 0.75 ± 0.5
(65/85/204 MHz) Max. operating level to CENELEC - CTB > 67 [dB] ²) 95 105
Depending on Max. operating level to CENELEC - CSO > 64 [dB] ²) 95 105
Slope range, electronically adjustable [dB] 0.4 – 8 / 0.8 – 9.5 / 1 – 15 Diplex filter set
(65/85/204 MHz) Pre-emphasis (fixed) [dB] 10 11

Return loss 8- 65 / 85 / 204 MHz [dB] 19 Noise figure[dB] 7

ICS attenuation (can be switched via EMS or WiFi module) Hum modulation at 7A [dB] 70
0 / 6 / >45
[dB]
Return path
Hum modulation at 7A (>15 MHz) [dB] > 70
Frequency range [MHz] 5-65 5-204
Test point [dB] 0
Attenuation (fixed) ± 0.75 dB [dB] 2.5
General data
Spurious (> 15 MHz) [dBµV] < 15
Impedance [Ω] 75
General data
Nominal supply voltage range, sine wave [VAC] 28 – 65
Power supply [V AC] 30-72
Power consumption without transponder [W] 27
Power consumption, max. [W] 5
Max. remote feed current, local injection [A] 10
Max. remote feed current (power passing) [A] 7
Max. remote feed current, normal operation per RF port
10 RF connections 5/8"
[A]
RF input and output interfaces 3 x PG11 Housing protection class IP 65 ¹)

Protection class acc. to DIN EN 60529 IP 54 Ambient temperature range [°C] -40 to +60

Ambient temperature range (in operation, compliant with Housing material Aluminum die cast
-25 to +60
specified data) [°C]
Overvoltage protection to IEC 60-2 6 kV (1.2/50 µs)
Over voltage protection 6kV; 1.2/50µs, (IEC 60-2)
Dimensions (W × H × D) [mm] 142 x 113 x 68
Housing material Aluminum die cast
¹) Providing a suitable plug is used ²) CENELEC, 41 channels output level @862 MHz
Dimesions (W x H x D) [mm] 3) 240 x 95 x 240
All data listed are typical values unless indicated otherwise.
Network management (optional)

Remote feed voltage, secondary current, supply voltage booster


amplifier, temperature, electronic tuning element values, pilot
Parameters for remote management and configuration settings and alarms, automatic levelling, summer / winter offset,
ICS, remote inventory date, downstream frequency range, diplex
filter set

¹) CENELEC 41 channels, level at 862 MHz, 10 dB slope hinge at 1.2 GHz


²) Setting via handheld / Wi-Fi module. Min. ratio between pilot frequency Pu and Po 250 MHz
³) Width incl. lid hinges: 267 mm
All data are typical values unless indicated otherwise.  See additional data on the next page

34 HFC HFC 35
Technical data

Type VOS 952-1G VOS 953-1G Comments Type VOS 952-1G VOS 953-1G Comments

24410162 24410163 Network management


Order no.
Locally fed Remotely fed
Internal supply voltage, internal power
Parameters for remote management and
Forward path consumption, internal temperature,
configuration
ICS switch
Frequency range [MHz] 47/85-1006
Test Points
Gain (1 dB steps via slide switches) [dB] 1) 40 Interstage setting
Input test point (internal), two-way [dB] 20 Test point 1, 5-1006 MHz
Frequency response [dB] ± 0.75 85-1006 MHz, at 25°C
Test point 2, 5-1006 MHz,
Frequency response
-0.5 At 25°C Return path signal injection
(additionally from 862-1006 MHz) [dB] Output test point (external), directional coupler
20 (5-65 MHz). Push and hold
[dB]
Attenuation range [dB] 0-16 At the amplifier input button to change direction and
measure return path ingress
At the amplifier input and
Pre-emphasis range [dB] 0-16 and 0/8
interstage Test point 3, 5-65 MHz with
Return path test point (external), two-way [dB] 10
directional coupler
Noise factor [dB] 4/5/5 At 40/36/32 dB gain
Switched mode power supply
Max. operating level: CENELEC channel plan CTB: 60 dB/CSO: 60 dB
112/116
[dBµV] 1) (pre-emphasis 6 dB and gain 40 dB) Nominal input voltage [V AC] 110-230 38-65

Hum modulation ratio [dB] - > 60/70 Mains frequency range [Hz] 50-60

Return path Power consumption (without monitoring) [W] 11 12

Frequency range [MHz] 5-65 General data

Gain switchable [dB] 30/21 Ambient temperature range [°C] -20 to +55

Frequency response [dB] ± 0.75 RF connections F socket

Amplitude response [dB] 0.5 Test Points F socket

Attenuation range [dB] 0-16 and 0/4/8 At input/interstage Protection protection class (to EN 60529) IP 54

Pre-emphasis range [dB] 4) 0/3/6 Interstage Dimensions (W × H × D) [mm] 225 × 55 × 155

Ingress control switch (ICS) [dB] 0/8/> 40 Attenuated/switched off Weight [kg] 1.8

60 dB IMA2/IMA3
Max. output level at 30 and 21 dB gain [dBµV] 107/116
(EN 60728-3/50083-5)

Maximum output level acc. to KDG 1 TS 140


120 Full system load
[dBµV]

Input level density [dBµV/Hz] -10 ¹) CENELEC: 41 channels at 862 MHz


²) When the 15 MHz high-pass filter is connected, the dynamic range increases by 3 dB. All data listed are typical values unless indicated
Dynamic range at 30 dB gain
20 otherwise.
(5-65 MHz) [dB] 2)

Dynamic range at 21 dB gain


30
(5-65 MHz) [dB] 2)

Noise figure [dB] 5

 See additional data on the next

36 HFC HFC 37
Technical data

Accessories

Type TVM 500 TVM 500S Type EAC 90-1G2 EAC 93-1G2 EAC 94-1G2 EBC 90-1G2

Order no. 26210846 26210868 Order no. 24510215 24510216 24510220 24510214
Input frequency range [MHz] 300-320; 425-450; 863-870; 902-928 Frequency range [MHz] 5-1218 5-1218 5-1218 5-1218
Input level range [dBµV] 48-95 Through loss 5-15 MHz [dB] ¹) < 1.5 < 2.2 < 0.3 < 3.4
Impedance [Ω] 75 Through loss 15-65 MHz [dB] ¹) < 1.3 < 2.0 < 0.3 < 3.4
Power consumption [W] 0.4 0.2 Through loss 65-862 MHz [dB] ¹) < 1.3 < 2.7 < 0.6 < 3.5
Modulation type FSK Through loss 862-1006 MHz [dB] ¹ )
< 1.5 < 3.1 < 0.7 < 3.7
Fiber nodes and controlled trunk / Through loss 1006-1218 MHz [dB] ¹) < 1.6 < 3.1 < 0.9 < 3.9
Suitable for device types VGXxxxxD-1G2
distribution network amplifiers
Same as
Tap loss [dB] 10 6 20
through loss

Isolation / directional attenuation [dB] 28 28 28 26


Type TVM 1000 Impedance [Ω] 75 75 75 75

Order no. 26210086

Input frequency range [MHz] 90-862 Type EAC 90-1G EAC 93-1G EAC 94-1G EBC 90-1G

Input level range [dBµV] 48-78 Order no. 24510116 24510115 24510114 24510113
Output frequency range [MHz] 5-65 Frequency range [MHz] 5-1006 5-1006 5-1006 5-1006
Max. output level [dBµV] 113-118 Through loss 5-610 MHz [dB] ¹ )
< 1.3 < 2.1 < 0.5 < 3.6
Power consumption [W] 3.5 Through loss 610-862 MHz [dB] ¹) < 1.3 < 2.3 < 0.6 < 3.8
Transmission protocol DOCSIS/EuroDOCSIS 2.0 Through loss 862-1006 MHz [dB] ¹ )
< 1.5 < 2.6 < 0.9 < 3.9
Suitable for device types Fiber nodes, controlled trunk / distribution network amplifiers, house connection amplifiers Same as
Tap loss [dB] 10 6 20
through loss

Isolation 5-65 MHz [dB] > 28 > 23 > 38 > 28

Isolation 65-610 MHz [dB] > 26 > 23 > 33 > 22


Type WTE 10
Isolation 610-862 MHz [dB] > 24 > 23 > 30 > 20

Order no. 25010086 Isolation 862-1006 MHz [dB] > 22 > 20 > 28 > 18

WiFi standard IEE 802.11 b/g/n


¹) The through loss is the attenuation of the signal between the signal output of the device and output 1 if used in the output insert position or
Frequency range [GHz] 2.4 between the input and tap input if used in the input insert position (loop-through input splitter field)
Encryption WPA, WPA2 AES PSK

Maximum transmission power [dBm] + 18

Power consumption [W] 3.5

Ambient temperature range [°C] -20 to +50

Housing protection class


IP 54
(to EN 60529)

38 HFC HFC 39
Technical data

Type EBC 00-1G2 EBC 00-1G Order number overview


Order no. 24510217 24510119

Frequency range [MHz] 5-1218 5-1006 Type Order no. Type Order no.
Through loss [dB] ¹ )
0.5
A T
ALSCM 10 24510232 TVM 1000 26210086
E TVM 500 26210846
Type ERC 22 ERZ 940 ERZ 630 ERS 800
EAC 90-1G 24510116 TVM 500S 26210868
Order no. 24510085 24510059 24510108 24510109 EAC 90-1G2 24510215 V
Transmission range [MHz] 50-862 47-862 47-630 47-862 EAC 93-1G 24510115 VGE 12258-1G2 24410184
Nominal impedance [Ω] 75 EAC 93-1G2 24510216 VGE 1285-1G2 24410145
Pre-emphasis For C-lines < 2.0 - - EAC 94-1G 24510114 VGP2143D-1G2 690017-xx1)

De-emphasis [dB] - 7±1 - - EAC 94-1G2 24510220 VGP3243D-1G2 690018-xx1)

Equalisation, adjustable in 2 dB steps [dB] - - 2-18 - EBC 00-1G2 24510217 VGX2143D-1G2 690019-xx1)
EBC 01E-1G 24510119 VGX 242D-1G2 24410188
Cable-equivalent pre-emphasis, 47-700 MHz/
- - - 3/(4)
(equivalent to 47-862 MHz) [dB] EBC 90-1G 24510113 VOS 952-1G 24410098

Cable-equivalent pre-emphasis EBC 90-1G2 24510214 VOS 953-1G 24410099


- - - 3
in range 700-862 MHz [dB] EMP 34 275289 W
Basic loss (at 862 MHz) [dB] 1 0.3 - 0.5 EMP 35 275300 WFS 906-1G2 24510218
Basic loss (at 47/630 MHz) [dB] - - 0.5/1.5 - EMU 29 273243 WFS 908-1G2 24510222

Return loss [dB] 23 -1/oct. typ. 20 min. 17 - > 15 ERC 22 24510085 WFS 920-1G2 24510209
ERD 813 24510117 WTE 10 25010086
ERD 814 24510120
Type ERD 813 ERD 814 ERD 815 ERP 101 ERD 815 24510127 1)
Generic odering numbers. Please contact info@bktel.com for
ERP 101 24510128 available configurations.
Order no. 24510117 24510120 24510127 24510128
ERR 9065 24510156
Transmission range [MHz] 85-1006
ERR 9085 24510158
Nominal impedance [Ω] 75
ERR 9204 24510211
Attenuation (linear) [dB] 1 6 10 1.8
ERS 630 24510108
Tap loss E -> A2 @ 85 MHz [dB] - - - 6
ERS 800 24510109
De-emphasis (862 MHz) [dB] 7 - - 3 ¹)
ERS 9085-1G2 24510219
De-emphasis (1 GHz) [dB] 8 - - 4 ERS 9105-1G2 24510223
Return loss [dB] 20 -1.5/octave 25 18.5 -1.0/octave ERS 9258-1G2 24510210
ERZ 940 24510059

¹) The through loss is the attenuation of the signal between the signal output of the device and output 1 if used in the output insert position or
between the input and the tap input of the device if used in the input insert position (splitter field loop-through input).
2)
Based on 85-862 MHz

40 HFC HFC 41
Notes

42 HFC HFC 43
BKtel communications GmbH Representations:

Benzstrasse 4 BKtel Pacific Rim (Japan) Inc.


41836 Hueckelhoven-Baal Katsukou Building 5F
Germany 1-2-8, Hourai-cho, Naka-ku,
Phone: +49 (0) 24 33 / 91 22-0 Yokohama, Kanagawa 231-0048,
Fax: +49 (0) 24 33 / 91 22-99 Japan
Phone: +81 45 350 5447
Office Kornwestheim:
Fax: +81 45 350 5460
Bahnhofstrasse 82
70806 Kornwestheim
BKtel Latam
Germany
Oficina de Representación
Phone: +49 (0) 71 54 / 1 59 90-0
Pedro Torres n.º 231, planta 302
Fax: +49 (0) 71 54 / 1 59 90-77
Municipalidad de Ñuñoa
Santiago, Chile
BKtel networks GmbH Phone: +56 220 468 46
Email: berriozabal@bktel.com
Mangfallstrasse 37
83026 Rosenheim
Germany BKtel local representatives:
Phone: +49 (0) 80 31 / 7 96 75-0
Fax: +49 (0) 80 31 / 7 96 75-99 France:
André Balva
balva@bktel.com
Internet: www.bktel.com
Email: info@bktel.com South East Asia:
Roland Wuerth
wuerth@bktel.com
11/2018 Compact Amplifier

44 HFC

You might also like