Professional Documents
Culture Documents
Compact - Amplifiers BKtel 1118 Final
Compact - Amplifiers BKtel 1118 Final
HFC 1
HFC Network Architectures
Overview 4
▪▪ VGX 242D-1G2 8
▪▪ VGP2143D-1G2 14
2 HFC HFC 3
Overview Compact Amplifiers
4 HFC HFC 5
VGX distribution network amplifier
VGX2143D-1G2
The VGX2143D-1G2 is a distribution network amplifier can be configured using the WTE 10 Wi-Fi module together with
designed for current and future DOCSIS 3.1 HFC networks. a Web browser. The return path bandwidth is determined by the
The amplifier features up to two outputs and an additional plug-in diplex filter sets.
loop-through output. All electronic settings of the amplifier
13
3
2 Block diagram
8
7
1
6
5 Features
9 ▪▪ Modern compact amplifier for DOCSIS 3.1 HFC networks ▪▪ Insert position for TVM 500S FSK transponder
10 11
▪▪ Frequency range: up to 1218 MHz ▪▪ Test sockets at the input/output and in the return path
12
▪▪ High gain (up to 46 dB) amplifier
14
15 4
▪▪ Loop-through output, configurable via the input splitter ▪▪ Built-in return path amplifier, adjustable electronically
field "Loop-Through" ▪▪ Ingress control switch (ICS)
▪▪ Two distribution outputs, configurable via the output ▪▪ Die-cast aluminium housing with 5/8" connections
splitter field
▪▪ End stage in the latest GaN technology Note
Standard version: Modules for the following insert positions are not ▪▪ Innovative operating concept: Electronic actuators,
included in the product package: setting via a WTE 10 WiFi module During operation, an EBC/EAC xx must be plugged into
6 HFC HFC 7
VGX distribution network amplifier
VGX 242D-1G2
The VGX 242D-1G2 is a distribution network amplifier tronic settings of the amplifier can be configured using the
designed for current and future DOCSIS 3.1 HFC net- WTE 10 Wi-Fi module together with a Web browser. The return
works. The amplifier features up to two outputs. All elec- path bandwidth is determined by the plug-in diplex filter sets.
13 3
8
2
7
1
Block diagram
9 5
6
10 11 Features
12 ▪▪ Modern compact amplifier for DOCSIS 3.1 HFC networks ▪▪ Test sockets at the input/output and in the return path
14 ▪▪ Frequency range: up to 1218 MHz amplifier
4
▪▪ High gain (up to 42 dB) ▪▪ Built-in return path amplifier, adjustable electronically
▪▪ Two distribution outputs, configurable via the output ▪▪ Ingress control switch (ICS)
splitter field ▪▪ Die-cast aluminium housing with 5/8" connections
▪▪ End stage in the latest GaN technology
▪▪ Innovative operating concept: Electronic actuators,
Standard version: Modules for the following insert positions are not setting via a WiFi module Note
included in the product package: ▪▪ Optional ALSC module with frequency-agile 2-pilot
control speeds up commissioning During operation, an EBC/EAC xx must be plugged into
1 Connection socket for the WTE 10 Wi-Fi adapter 8 Insert position for FSK multi-band transponder module • Automatic levelling on the forward path saves time- the insert position at the output. Zero cards are already
consuming manual calibration plugged into the insert positions No. 2, 3, 4.
2 “Forward 1” and JXP insert position 9 Insert position for 2-pilot control module • Return path can be pre-adjusted automatically
▪▪ Very high output level with lowest intermodulation
3 “Forward 2” insert position 10 Plug-in input diplex filter
products even with interstage attenuation
8 HFC HFC 9
VGX distribution network amplifier
tionary
Revolu
t
▪▪ State-of-the-art switched-mode power supply unit technology with very long concep
service life
▪▪ Active power factor correction with a factor of almost 1 1
▪▪ Improved dissipation of waste heat from the entire power supply unit thanks to
the heatsink coating. This results in a lower heat load in the device itself and
also helps to increase the maximum operating temperature range
▪▪ The power supply unit is easy to replace in the event of maintenance:
• Easily accessible plug-in contacts and screw connections
Function can be adjusted to suit requirements in a modular way
• No thermal pad required. This removes the need for positioning the pad and
eliminates the risk of losing it
▪▪ Insert position for 2-pilot control module. This enables cost-effective use of
the device for controlled and uncontrolled operation
3
2 Single-chamber shielding system ▪▪ FSK transponder insert position for TVM 500S for controlling the ICS switch
and for carrying out base unit updates remotely
▪▪ Customer-specific insert positions in the forward and return path enable
2 additional manual signal adjustment for built-in electronic set-up
▪▪ Insert position for operation in different frequency ranges (1.2 GHz/1 GHz)
(Hingepoint for 1.2 GHz pre-mounted)
Familiar modularity
▪▪ High mutual shielding between forward path, return path and other ▪▪ Customer-specific interstage forward insert position for plug-in cards such as
functional areas in the device. This prevents cross modulation and other system equalisers
unwanted coupling effects ▪▪ Plug-in diplexers for adjusting the frequency split of forward and return path
▪▪ Improved temperature discharge thanks to the built-in thermal dissipation ▪▪ Output insert field, individually configurable for one to two outputs with
domes on the bottom and top of the components. This results in a lower EBC/EAC xx-1G2 splitter or tap plug-in cards
heat load in the surrounding components and also helps to increase the ▪▪ Splitter field input (VGX2143D-1G2 only) for individual loop-through
maximum operating temperature range output configuration using EBC/EACxx-1G2 splitter and respectively tap
plug-in cards
10 HFC HFC 11
Controlled trunk / distribution network amplifiers
VGP3243D-1G2 TP OUT 1
The VGP3243D-1G2 is a dual mode trunk / distribution net- bution network outputs. The output level of the amplifier are 2
dB HP OUT 1
work amplifier designed for current and future DOCSIS 3.1 HFC pilot controlled. All amplifier settings are made electronically using
LP
networks. Two active output stages can be configured for up to 3 the handheld or Wi-Fi module with a Web browser.
Plug In Plug In TP OUT 2
high level distribution network or 1 trunk level and up to 2 distri- Position dB HP dB Position
TP IN
OUT 2
IN HP Docsis/HMS/FSK Transponder HP
OUT 3
LP LP
dB ICS
Plug In
Position dB LP dB
8
1 dB ICS Ingress
Test
Block diagram
3
11
Features
2
▪▪ Modern controlled amplifier with remote monitoring for ▪▪ Insert position for monitoring transpoder
6 5 DOCSIS 3.1 HFC networks (FSK/HMS/DOCSIS)
4
9 9 ▪▪ Frequency range: up to 1218 MHz ▪▪ Test sockets at the input/output and in the return path
10 (selectable between 1006 MHz and 1218 MHz) amplifier
12 ▪▪ Configuration of up to 3 high level distribution or 1 trunk ▪▪ Built in return path amplifier, adjustable electronically
level and up to 2 distribution network outputs ▪▪ Ingress control switches (ICS)
▪▪ GaN second generation 2 active outputs amplifier ▪▪ Die cast aluminum housing with PG 11 connections
7 ▪▪ Innovative operating concept: Electronic actuators setting
by Wi-Fi module (minimizing plug in cards and attenua-
Standard version: Modules for the following insert positions are not tion pads. Exactly readable and reproducible settings)
included in the product package: ▪▪ Built in frequency agile 2 pilot control speeds up com- Note
missioning:
1 Connection socket for handheld / Wi-Fi adapter 8 Insert position for monitoring transponder module • Automatic levelling on the forward path saves time During operation, an EBC/EAC xx must be plugged into
consuming manual setting the output splitter field. Pass through cards are already
2 “Forward 1” insert position 9 Plug-in output diplex filter • Return path can be adjusted automatically plugged into the insert positions no. 2 and 3. The optional
▪▪ Remote configuration of all tuning parameters supported HMS monitoring transponder TVM 850 can only be used
3 “Forward 2” insert position 10 Plug-in input diplex filter
by monitoring system (can be deactivated) up to a maximum return path frequency of 65 MHz.
4 Plug in low pass filter “TP Return Path” 11 Plug-in high pass filter “HP Forward Path”
▪▪ Very high output level (115 dBµV) with very low inter-
modulation products even with interstage attenuation
5 F test socket internal (-20 dB) output 12 Splitter field output (splitters, taps) ▪▪ Remote feed capability: Up to 10 A at each input/
output, local feed: 10 A For an overview of accessories, see page 20-28.
6 F test socket internal (-20 dB) input
12 HFC HFC 13
Controlled trunk / distribution network amplifiers
VGP2143D-1G2
The VGP 2143D-1G2 is a distribution network amplifier All amplifier settings are made electronically using the handheld
designed for current and future DOCSIS 3.1 HFC networks. or Wi-Fi module with a Web browser. The return path bandwidth
One active output stage can be configured for up to 2 high is determined by various plug in diplex filter sets.
level distribution network outputs.
8 1
Block diagram
3
11
6 5 Features
4
9 ▪▪ Modern controlled amplifier with remote monitoring for ▪▪ Insert position for monitoring transpoder
10 DOCSIS 3.1 HFC networks (FSK/HMS/DOCSIS)
12 ▪▪ Frequency range: up to 1218 MHz (selectable between ▪▪ Test sockets at the input/output and in the return path
1006 MHz and 1218 MHz) amplifier
▪▪ Configuration of up to 1 distribution network outputs ▪▪ Built in return path amplifier, adjustable electronically
7 ▪▪ High gain: up to 43 dB controlled ▪▪ Ingress control switches (ICS)
▪▪ GaN second generation 1 active output amplifier ▪▪ Die cast aluminum housing with PG 11 connections
Standard version: Modules for the following insert positions are not
▪▪ Innovative operating concept: Electronic actuators setting
by Wi-Fi module (minimizing plug in cards and attenua-
included in the product package: Note
tion pads. Exactly readable and reproducible settings)
1 Connection socket for the WTE 10 Wi-Fi adapter 8 Insert position for monitoring transponder module ▪▪ Built in frequency agile 2 pilot control speeds up During operation, an EBC/EAC xx must be plugged into
commissioning: the output splitter field. Pass through cards are already
2 “Forward 1” insert position 9 Plug-in output diplex filter • Automatic levelling on the forward path saves time plugged into the insert positions no. 2 and 3. The optional
consuming manual setting HMS monitoring transponder TVM 850 can only be used
3 “Forward 2” insert position 10 Plug-in input diplex filter • Return path can be adjusted automatically up to a maximum return path frequency of 65 MHz.
▪▪ Remote configuration of all tuning parameters supported
4 Plug in low pass filter “TP Return Path” 11 Plug-in high pass filter “HP Forward Path” by monitoring system (can be deactivated)
▪▪ Very high output level (115 dBµV) with very low inter-
5 F test socket internal (-20 dB) output 12 Splitter field output (splitters, taps) modulation products even with interstage attenuation
▪▪ Remote feed capability: Up to 10A at each input/output,
6 F test socket internal (-20 dB) input local feed: 10 A For an overview of accessories, see page 20-28.
14 HFC HFC 15
Uncontrolled equaliser amplifiers
The VGE equaliser amplifier is ideal for supplementary compen- it offers an plug-and-play solution that is easy to install. The
sation of cable attenuation in the case of a network upgrade. return path, which goes from 5 to 65 MHz or 5 to 204 MHz
respectively, is passive with a low attenuation of max. 2.5 dB.
The forward range starts at 85 MHz or 258 MHz respectively and Power can be supplied to the amplifier by connecting a remote
goes up to 1218 MHz. A slope of 10 dB or 11 dB respectively on feed to the input or output. The input or output can also be used
the upstream cable network resulting from long cable lengths is to supply looped-through remote feed currents up to 7 A to the
compensated. As the amplifier requires no manual set-up, upstream or downstream amplifiers.
16 HFC HFC 17
House connection amplifiers
The compact and very reasonably priced VOS 952-1G and VOS particular note include the high dynamic range during interstage Pre-emphasis Attenuation Pre-emphasis Attenuation
953-1G house connection amplifiers have been designed for use operation and a money-saving operating concept with slide Current
Temperature
in modern HFC networks. Features of its design worthy of switches. Operating voltage
Monitoring transponder
passive passive
active active
3 8
1 2
9 Pre-emphasis Attenuation
Attenuation
2 "switched off"
Ingress detection
two-way
Pre-emphasis
internal
switched off
Return path
3 two-way
Output
8
Input
(Return path:
5
Block diagram
3
7
Features
▪▪ Monitorable house connection amplifiers for modern ▪▪ Directional coupler test socket at the amplifier output
6 4 HFC networks and on the return path
▪▪ The latest GaAs-MMIC technology ▪▪ Feature for injecting test signals for the return path
Standard version: Modules for the following insert positions are not included in
▪▪ Innovative operating concept: ▪▪ Highly efficient switched mode power supply unit
the product package:
• Set-up via slide switches ▪▪ VOS 952-1G - local feed, F sockets
• Exactly reproducible device settings ▪▪ VOS 953-1G - remote feed (for auto-supply), F sockets
1 LED (power supply function) 8 Input insert position e.g. for de-emphasis equaliser • Fewer plug-in cards and attenuation pads required ▪▪ Voltage surge conductors on all RF connections and in
▪▪ Very high output level with very low intermodulation the switched mode power supply unit
2 Forward path: attenuation and equalisation are 9 Insert position for the monitoring transponder products ▪▪ Die-cast housing
set with slide switches ▪▪ Built-in active and passive return path with numerous ▪▪ Test sockets: F sockets
setting options
3 Built-in return path amplifier can be adjusted with
▪▪ 1-band operation available, requires no return path
slide switches
▪▪ 15 MHz high-pass filter can be activated on the return
path
4 F test socket at the output for return path
measurement or feed (-20 dB)
▪▪ Ingress control switch (ICS)
▪▪ HMS or DOCSIS monitorable (option)
5 Return path can be switched between passive/active ▪▪ Insert position for additional functions on the forward
path (e.g. de-emphasis)
6 F test socket for the return path (-10 dB) ▪▪ Two-way test socket at the amplifier input with inductive For an overview of accessories, see page 20-28.
decoupling
7 Two-way F test socket at the input (-20 dB)
18 HFC HFC 19
Accessories
Accessories
Overview of accessories for the VGX distribution network amplifiers Overview of accessories for controlled trunk / distribution network amplifiers
Description Type Order no. VGX xxxxD-1G2 Description Type Order no. VGP xxxxD-1G2
Zero card for operation with one output 1.2 GHz EBC 00-1G2 24510217 Zero card for operation with one output 1.2 GHz EBC 00-1G2 24510217
Splitter (two symmetrical outputs) 1.2 GHz EBC 90-1G2 24510214 Splitter (two symmetrical outputs) 1.2 GHz EBC 90-1G2 24510214
Tap (3/6 dB) 1.2 GHz EAC 93-1G2 24510216 Tap (3/6 dB) 1.2 GHz EAC 93-1G2 24510216
Tap (1.5/10 dB) 1.2 GHz EAC 90-1G2 24510215 Tap (1.5/10 dB) 1.2 GHz EAC 90-1G2 24510215
Tap (0.8/20 dB) 1.2 GHz EAC 94-1G2 24510220 Tap (0.8/20 dB) 1.2 GHz EAC 94-1G2 24510220
FSK multi-band transponder module TVM 500 26210846 - FSK multi-band transponder module TVM 500 26210846
FSK multi-band transponder module, small TVM 500S 26210868 FSK multi-band transponder module, small TVM 500S 26210868 -
DOCSIS monitoring transponder TVM 1000 26210086 - DOCSIS monitoring transponder TVM 1000 26210086
WiFi module for wireless setting via a Webbrowser WTE 10 25010086 WiFi module for wireless via a Webbrowser WTE 10 25010086
Automativ level and slope control module ALSCM 10 24510232 Adapter ring PG 11 to 5/8" EMU 29 273243
PG 11 to 3.5/12 connector (female) EMP 53 25010011 - Adapter PG 11 to 3.5/12 socket EMP 53 25010011
PG 11 to IEC connector (female) with M14 male thread EMP 34 275289 - PG 11 to IEC connector (f) with M14 male thread EMP 34 275289
Diplexer 65/85 MHz WFS 906-1G2 24510218 Diplexer 65/85 MHz WFS 906-1G2 24510218
Forward path equaliser 85 MHz ERS 9085-1G2 24510219 Forward path equaliser 85 MHz ERS 9085-1G2 24510219
Return path equaliser 65 MHz ERR 9065 24510156 Return path equaliser 65 MHz ERR 9065 24510156
Diplexer 85/105 MHz WFS 908-1G2 24510222 Diplexer 85/105 MHz WFS 908-1G2 24510222
Forward path equaliser 105 MHz ERS 9105-1G2 24510223 Forward path equaliser 105 MHz ERS 9105-1G2 24510223
Return path equaliser 85 MHz ERR 9085 24510158 Return path equaliser 85 MHz ERR 9085 24510158
Diplexer 204/258 MHz WFS 920-1G2 24510209 Diplexer 204/258 MHz WFS 920-1G2 24510209
Forward path equaliser 258 MHz ERS 9258-1G2 24510210 Forward path equaliser 258 MHz ERS 9258-1G2 24510210
20 HFC HFC 21
Accessories
Overview of plug-in diplex filter sets Description Type Order no. VOS 952-1G VOS 953-1G
Description Type Order no. VOS 952-1G VOS 953-1G Return path equaliser 65 MHz ERR 9065 24510156 - -
22 HFC HFC 23
Accessories
The WTE 10 WiFi moduleallows connected amplifiers and fibre nodes to be accessed Tap/splitter plug-in cards
conveniently from a PC, tablet or smartphone for configuration purposes. To view the
EAC 90-1G2, EAC 93-1G2, EAC 94-1G2, EBC 90-1G2
configuration, only a Web browser supporting JavaScript is required. The WTE 10 Wi-Fi
module simply has to be connected to the controlling device (plug-and-play connection); ▪▪ Plug-in modules to expand the corresponding device to two outputs
it draws its power supply from the controlling device. ▪▪ Can be used in the splitter field loop-through input
▪▪ Suitable for amplifiers and fibre nodes
Actual product not shown
Features
▪▪ WiFi standard to IEEE 802.11 b/g/n
▪▪ Display of all device settings via a Web interface
▪▪ Ambient conditions: Tap/splitter plug-in cards
• Operating temperature: -20 to +50°C
EAC 90-1G, EAC 93-1G, EAC 94-1G, EBC 90-1G
• Suitable for outdoor use
• Housing protection class: IP 54 ▪▪ Plug-in modules to expand the corresponding device to two outputs
▪▪ Language: English ▪▪ Can also be used in the splitter field loop-through input depending on device type
▪▪ Copy function for saving the device settings ▪▪ Suitable for amplifiers and legacy 1 GHz fiber nodes
▪▪ No additional power supply necessary
▪▪ Can be updated in order to support new devices and functions Actual product not shown
24 HFC HFC 25
Accessories
3
dB
4
Features Features 5
▪▪ Plug-in modules for trough connection e.g. for operation with one output ▪▪ System equaliser for use in special application cases 7
Features
▪▪ Creates a pre-emphasis based on the C-line specification for german networks
▪▪ For use in the universal input insert position (“Forward 1”) De-emphasis equaliser/attenuation attachment
ERD 813, ERD 814, ERD 815, ERP 101
Features
▪▪ Equaliser, 47-630 MHz
▪▪ Adjustable from 2-18 dB in 2 dB steps (cable equivalent)
▪▪ For use in the input insert position of the VOS 95x and other amplifiers
26 HFC HFC 27
Accessories Technical data
Number of outputs 1 or 2
Return path
28 HFC HFC 29
Technical data
Additional amplitude response over attenuation, slope and Type VGP3243D-1G2 Comments
± 0.4
temperature [dB]
Input noise density (CINR = 50 dB, 25 dB gain flat) Order no. 690018-xx
-9
[dBµV / Hz] Forward path
Dynamic range: CINR > 50 dB, 5-65 MHz, 25 dB gain Modes Trunk Distribution network
25
[dB]
Number of trunk outputs 1 0
Depending on
Attenuation range, electronically adjustable [dB] 5 – 30 / 4 – 30 / 0 - 30 Diplex filter set Number of distribution outputs 1 or 2 2 or 3
(65/85/204 MHz) Frequency range [MHz]; upper limit selectable 85 – 1006 / 1218
Depending on Gain (at 1218 MHz) uncontrolled / controlled [dB] 40 / 37 46 / 43
Slope range, electronically adjustable [dB] 0.4 – 7.5 / 0.8 – 9 / 1 - 14 Diplex filter set
(65/85/204 MHz) Return loss [dB] 18 – 1.5 dB / oct. (min.13)
ICS attenuation (can be switched via EMS or WiFi module) Frequency response (85 – 1218 MHz at 25°C) [dB] ± 0.5
0/6/> 45
[dB] Frequency response additional [dB] ± 0.8
Hum modulation at 7A (>15 MHz) [dB] 70 Maximum input level [dBµV] 85
Spurious (> 15 MHz) [dBµV] < 15 Maximum operation output level [dBµV] 115
General CSO at 43dB gain, 10 dB slope at 1.2GHz, [dB] 70 67
Impedance [Ω] 75 CENELEC 41 carriers, level at 862MHz [dBµV] 106 112
AC supply voltage including tolerances [V] 30-90 CTB at 43dB gain, 10 dB slope at 1.2GHz, [dB] 75 70
CENELEC 41 carriers, level at 862MHz [dBµV] 106 112
Power consumption (High/Low Mode) [W] 20/17 21/18
Max. remote feed current per connection [A] 7 Attenuation range, electronically adjustable [dB] 0 – 16
Over voltage protection 6 kV; 1.2/50 µs, (IEC 60-2) Automatic gain control range [dB] ±3
Dimensions (W × H × D) [mm] 250 × 201 × 95 Frequency range of lower pilot Pu (PAL/CW/QAM) MHz 1) 120 - 450
30 HFC HFC 31
Technical data
Return loss 8- 65 / 85 / 204 MHz [dB] 19 Maximum operating level [dBµV] 115
ICS attenuation (can be switched via EMS or Wi-Fi module) CSO ratio, 1 x 106 dBµV [dB] 1)
67
0 / 6 / >45
[dB]
CTB ratio, 1 x 106 dBµV [dB] 1) 70
Hum modulation at 7A (>15 MHz) [dB] > 70
Attenuation range, electronically adjustable [dB] 0 – 16
Test point [dB] 0
Slope range, electronically adjustable [dB] 1006 / 1218 MHz 0-13 / 15
General data
Interstage pre-emphasis range [dB] 1006 / 1218 MHz 0 – 15 / 17
Impedance [Ω] 75
Noise figure [dB] 8
Nominal supply voltage range, sine wave [VAC] 28 – 65
Automatic slope control range [dB] ±2
Power consumption without transponder [W] 42
Automatic gain control range [dB] ±3
Max. remote feed current, local injection [A] 10
Max. remote feed current, normal operation per Frequency range of lower pilot Pu (PAL/CW/QAM) MHz 2) 120 - 450
10
RF port [A]
Frequency range of upper pilot Po (PAL/CW/QAM) MHz 2) 420 - 998
RF input and output interfaces 4 x PG11
Output level, BER 10^ -9, 110ch. 256QAM,
Protection class acc. to DIN EN 60529 IP 54 111
258 – 1218 MHz, 10 dB slope [dBµV]
Ambient temperature range (in operation, compliant with
-25 to +60 Pilot carrier level range (PAL/CW/QAM) [dBµV] 87 -114
specified data) [°C]
Over voltage protection 6kV; 1.2/50µs, (IEC 60-2) Hum modulation [dB] 70
Housing material Aluminum die cast Spurious (> 85 MHz) [dBµV] < 15
¹) Setting via handheld / Wi-Fi module. Min. ratio between pilot frequency Pu and Po 250 MHz
²) Width incl. lid hinges: 267 mm
See additional data on the next page
All data are typical values unless indicated otherwise.
32 HFC HFC 33
Technical data
ICS attenuation (can be switched via EMS or WiFi module) Hum modulation at 7A [dB] 70
0 / 6 / >45
[dB]
Return path
Hum modulation at 7A (>15 MHz) [dB] > 70
Frequency range [MHz] 5-65 5-204
Test point [dB] 0
Attenuation (fixed) ± 0.75 dB [dB] 2.5
General data
Spurious (> 15 MHz) [dBµV] < 15
Impedance [Ω] 75
General data
Nominal supply voltage range, sine wave [VAC] 28 – 65
Power supply [V AC] 30-72
Power consumption without transponder [W] 27
Power consumption, max. [W] 5
Max. remote feed current, local injection [A] 10
Max. remote feed current (power passing) [A] 7
Max. remote feed current, normal operation per RF port
10 RF connections 5/8"
[A]
RF input and output interfaces 3 x PG11 Housing protection class IP 65 ¹)
Protection class acc. to DIN EN 60529 IP 54 Ambient temperature range [°C] -40 to +60
Ambient temperature range (in operation, compliant with Housing material Aluminum die cast
-25 to +60
specified data) [°C]
Overvoltage protection to IEC 60-2 6 kV (1.2/50 µs)
Over voltage protection 6kV; 1.2/50µs, (IEC 60-2)
Dimensions (W × H × D) [mm] 142 x 113 x 68
Housing material Aluminum die cast
¹) Providing a suitable plug is used ²) CENELEC, 41 channels output level @862 MHz
Dimesions (W x H x D) [mm] 3) 240 x 95 x 240
All data listed are typical values unless indicated otherwise.
Network management (optional)
34 HFC HFC 35
Technical data
Type VOS 952-1G VOS 953-1G Comments Type VOS 952-1G VOS 953-1G Comments
Hum modulation ratio [dB] - > 60/70 Mains frequency range [Hz] 50-60
Gain switchable [dB] 30/21 Ambient temperature range [°C] -20 to +55
Attenuation range [dB] 0-16 and 0/4/8 At input/interstage Protection protection class (to EN 60529) IP 54
Ingress control switch (ICS) [dB] 0/8/> 40 Attenuated/switched off Weight [kg] 1.8
60 dB IMA2/IMA3
Max. output level at 30 and 21 dB gain [dBµV] 107/116
(EN 60728-3/50083-5)
36 HFC HFC 37
Technical data
Accessories
Type TVM 500 TVM 500S Type EAC 90-1G2 EAC 93-1G2 EAC 94-1G2 EBC 90-1G2
Order no. 26210846 26210868 Order no. 24510215 24510216 24510220 24510214
Input frequency range [MHz] 300-320; 425-450; 863-870; 902-928 Frequency range [MHz] 5-1218 5-1218 5-1218 5-1218
Input level range [dBµV] 48-95 Through loss 5-15 MHz [dB] ¹) < 1.5 < 2.2 < 0.3 < 3.4
Impedance [Ω] 75 Through loss 15-65 MHz [dB] ¹) < 1.3 < 2.0 < 0.3 < 3.4
Power consumption [W] 0.4 0.2 Through loss 65-862 MHz [dB] ¹) < 1.3 < 2.7 < 0.6 < 3.5
Modulation type FSK Through loss 862-1006 MHz [dB] ¹ )
< 1.5 < 3.1 < 0.7 < 3.7
Fiber nodes and controlled trunk / Through loss 1006-1218 MHz [dB] ¹) < 1.6 < 3.1 < 0.9 < 3.9
Suitable for device types VGXxxxxD-1G2
distribution network amplifiers
Same as
Tap loss [dB] 10 6 20
through loss
Input frequency range [MHz] 90-862 Type EAC 90-1G EAC 93-1G EAC 94-1G EBC 90-1G
Input level range [dBµV] 48-78 Order no. 24510116 24510115 24510114 24510113
Output frequency range [MHz] 5-65 Frequency range [MHz] 5-1006 5-1006 5-1006 5-1006
Max. output level [dBµV] 113-118 Through loss 5-610 MHz [dB] ¹ )
< 1.3 < 2.1 < 0.5 < 3.6
Power consumption [W] 3.5 Through loss 610-862 MHz [dB] ¹) < 1.3 < 2.3 < 0.6 < 3.8
Transmission protocol DOCSIS/EuroDOCSIS 2.0 Through loss 862-1006 MHz [dB] ¹ )
< 1.5 < 2.6 < 0.9 < 3.9
Suitable for device types Fiber nodes, controlled trunk / distribution network amplifiers, house connection amplifiers Same as
Tap loss [dB] 10 6 20
through loss
Order no. 25010086 Isolation 862-1006 MHz [dB] > 22 > 20 > 28 > 18
38 HFC HFC 39
Technical data
Frequency range [MHz] 5-1218 5-1006 Type Order no. Type Order no.
Through loss [dB] ¹ )
0.5
A T
ALSCM 10 24510232 TVM 1000 26210086
E TVM 500 26210846
Type ERC 22 ERZ 940 ERZ 630 ERS 800
EAC 90-1G 24510116 TVM 500S 26210868
Order no. 24510085 24510059 24510108 24510109 EAC 90-1G2 24510215 V
Transmission range [MHz] 50-862 47-862 47-630 47-862 EAC 93-1G 24510115 VGE 12258-1G2 24410184
Nominal impedance [Ω] 75 EAC 93-1G2 24510216 VGE 1285-1G2 24410145
Pre-emphasis For C-lines < 2.0 - - EAC 94-1G 24510114 VGP2143D-1G2 690017-xx1)
Equalisation, adjustable in 2 dB steps [dB] - - 2-18 - EBC 00-1G2 24510217 VGX2143D-1G2 690019-xx1)
EBC 01E-1G 24510119 VGX 242D-1G2 24410188
Cable-equivalent pre-emphasis, 47-700 MHz/
- - - 3/(4)
(equivalent to 47-862 MHz) [dB] EBC 90-1G 24510113 VOS 952-1G 24410098
Return loss [dB] 23 -1/oct. typ. 20 min. 17 - > 15 ERC 22 24510085 WFS 920-1G2 24510209
ERD 813 24510117 WTE 10 25010086
ERD 814 24510120
Type ERD 813 ERD 814 ERD 815 ERP 101 ERD 815 24510127 1)
Generic odering numbers. Please contact info@bktel.com for
ERP 101 24510128 available configurations.
Order no. 24510117 24510120 24510127 24510128
ERR 9065 24510156
Transmission range [MHz] 85-1006
ERR 9085 24510158
Nominal impedance [Ω] 75
ERR 9204 24510211
Attenuation (linear) [dB] 1 6 10 1.8
ERS 630 24510108
Tap loss E -> A2 @ 85 MHz [dB] - - - 6
ERS 800 24510109
De-emphasis (862 MHz) [dB] 7 - - 3 ¹)
ERS 9085-1G2 24510219
De-emphasis (1 GHz) [dB] 8 - - 4 ERS 9105-1G2 24510223
Return loss [dB] 20 -1.5/octave 25 18.5 -1.0/octave ERS 9258-1G2 24510210
ERZ 940 24510059
¹) The through loss is the attenuation of the signal between the signal output of the device and output 1 if used in the output insert position or
between the input and the tap input of the device if used in the input insert position (splitter field loop-through input).
2)
Based on 85-862 MHz
40 HFC HFC 41
Notes
42 HFC HFC 43
BKtel communications GmbH Representations:
44 HFC