10. 1 Turbines
As described in Chap. 9, there are two general ways of classifying turbines: (1) by their
steam supply and exhaust conditions and (2) by their casing or shaft arrangement. They
are also identified by the equipment they drive, either mechanical equipment or an
electric generator. The type of drive, either direct or geared, is also used in describing a
turbine.
For large electric utility fossil-fuel-fired power plants in the United States, where
plant sizes range from 100 to 1300 MW, many of the large plant designs are based on
one of two system cycles:
1. Subcritical pressure systems of 2400 psig with 1000°F superheat and 1000°F
reheat temperatures
2. Supercritical pressure systems of 3600 psig with 1100°F superheat and 1100°F
reheat temperatures
However, with the presence of independent power producers (IPPs), where plant
sizes are less than 100 MW and various waste fuels are burned, many different plant
cycle designs are used, with many plant steam pressures less than 1000 psig and steam
temperatures of 750°F. Yet, the operating goals of these facilities are identical to those of
the large electric utility produce electricity at the lowest possible cost with the highest degree
-
of reliability while meeting all emission requirements of the operating permit. The lower steam
pressures and temperatures are often required because of inherent problems with
burning a certain fuel. For example, when burning municipal solid waste (MSW), high
steam pressures and temperatures are related to accelerated corrosion in the boiler
because of the corrosive nature of the fuel, which leads to low availability and high
maintenance costs.
Turbines are also used to drive mechanical equipment, and they often use low
pressure steam, less than 150 psig, which often comes from an extraction point within the
main steam turbine. Thus turbine steam pressures and temperatures vary significantly
523
524 C h a pter Te n
depending on the application. However, for each design, the pressure and tempera
ture of the steam supplied are important factors in determining the ultimate efficiency
of the turbine. The materials used in the construction of the turbine also play an important
part in the overall performance.
High-pressure, high-temperature steam turbines are used primarily in large indus
trial and utility power plants. Several types and applications are shown in Fig. 10.1.
Pressures for these types of turbines generally range from 400 to 3600 psig, with steam
temperatures to 1100°F. Most of the large units for electric utilities operate with reheat.
Here, the steam, after passing through the high-pressure stages of the turbine, is taken
back to a reheater in the boiler, where the steam is reheated to its initial temperature and
then returned to the turbine at a lower pressure.
The turbine in Fig. 10.2 is a tandem cross-compound unit. The upper portion shows
a high- and intermediate-pressure (tandem) turbine on a single shaft. The lower portion
is the low-pressure unit. Mounted on the right of each (not shown) are the electric
generators.
In operation, initial steam enters the high-pressure turbine at 3600 psig and 1100°F
through two inlets (top and bottom). It passes through the turbine to exit at the left
(and below) at approximately 600 psig and 550°F and then passes to a reheater in the
boiler, where the steam is again heated to 1100°F. On leaving the reheater, steam at a
pressure lower than 600 psig, because of pressure drop losses, and 1100°F enters the
intermediate unit (at bottom center) and passes through the double-flow turbine,
exhausting at the top through two outlets. This steam is at approximately 170 psig and
710°F when it passes to both sections of the low-pressure unit, finally exhausting to the
condenser.
This is an extraction turbine, steam being extracted from one stage of the high
pressure turbine and four stages of each low-pressure turbine. It is used for feedwater
heating. Note that the intermediate-pressure unit and both low-pressure units have
double-flow arrangements; that is, steam enters the turbine at the center and flows in
two directions. This unit has a capacity of approximately 900 MW.
Steam from a turbine may be exhausted into a condenser to obtain the maximum
amount of energy in the steam, or it may be removed at any intermediate pressure by
the use of a noncondensing or backpressure turbine. While the latter reduces the
amount of energy available to the turbine, it provides steam for process or space heat
ing. A compromise between the condensing and noncondensing arrangements is the
extraction turbine. Here, steam, having passed partway through the turbine, is removed
from the casing at a point or points with the desired steam conditions. The pressure at
a given turbine stage (i.e., connection to the casing) varies with the load. For this reason,
two methods of extraction are used: (1) The uncontrolled extraction method consists of
connection to the casing with varying pressures, increasing as the load increases and
decreasing as the load decreases. This arrangement is used extensively in power plants
for extraction feedwater heating. (2) The controlled extraction method maintains constant
pressure by regulating the flow of steam through the turbine on the downstream side of
the extraction point. This arrangement is used to obtain steam at constant pressure for
process or heating. The amount of superheat (or steam quality) delivered at the point of
extraction depends on the initial steam conditions and load on the turbine. The turbine
is adaptable to the use of steam at various pressures and temperatures. It can supply
maximum power in the condensing operation or a lesser amount of power in addition
O p e rat i n g a n d M a i n ta i n i n g Ste a m Tu r b i n e s 525
Steam Steam
i nlet i nlet
Steam Steam
i nlet i n let
Steam Steam
i nlet i n let
FIGURE 10. 1 Steam turb i n e types and a p p l i cations. (a) Condensi ng; used when exhaust steam
from the turbine cannot be used and power m u st be ge nerated on a m i n i m u m a m o u nt of stea m .
(b) Noncondensi ng; used when a l l or practica l ly a l l the exhaust steam from the turb i n e can be
used for process or heating. (c) S i ngle extractio n ; used when process steam req u i reme nts a re
va riable or i nterm ittent. (A noncondensing extraction turbine can be used when process steam i s
req u i red a t two d ifferent pressu res . ) ( d ) M ixed pressu re ; used w h e n excess steam i s ava i lable at
l owe r tha n i n let pressu re and when this su pply is i nterm ittent. (e) M ixed-pressure extraction ;
used to su pply process steam when necessa ry and to use a surplus of process steam when
ava i la b l e . (f) Double-extractio n ; used when process steam i s req u i red at two different pressu res
(or at three d ifferent pressures if noncondensing) .
to steam at a reduced pressure. Several types of turbines together with their applications
are shown in Fig. 10.1, as well as those described in Chap. 9.
Noncondensing turbines are used where process steam at only one pressure is
required and where no condensing water is available or the cost of providing it is pro
hibitive. Noncondensing turbines may be designed for one or more stages of extraction,
526 C h a pter Te n
Tu rning gear
To generator
l L. P. 1 L . P. 2
To condenser
FIGURE 10.2 Ta ndem cross-compound, 3600-rpm , fou r-flow, re heat steam turb i n e . (General
Electric Co. )
and such turbines lend themselves to the mixed-pressure extraction-type unit. Extraction
steam can be used for process and to drive plant auxiliaries such as pumps. Mixed
pressure extraction turbines are used in paper mills and other industries where large
quantities of steam at varying pressures are required at certain times, while at other
times a large amount of steam at a constant pressure is required.
In a single turbine, the steam expands from the initial condition to exhaust. The
tandem compound turbine consists of two separate units arranged in line with their
shafts connected end to end and with steam passing from the high- to the low-pressure
turbine. The cross-compound unit also consists of two separate turbines. These are
high- and low-pressure turbines mounted side by side with their shafts parallel. Refer
to Chap. 9 for descriptions.
Steam turbine drives are used for pumps, air compressors, fans, and other mechan
ical equipment. To be efficient, a turbine must operate at high speed. When the driven
unit also can be operated at high speed, the turbine shaft is connected by a coupling to
the driven shaft. When, however, a driven machine is required to operate at a lower
speed than that of the turbine, reducing gears are used to transmit the power.
When steam expands in a turbine, it imparts energy to the rotating shaft as it comes
into contact with the blades. This energy is taken from the steam, and as a result of this
heat loss, part of the steam is condensed, and moisture begins to form in the steam. The
water thus formed can do no work in the turbine; in fact, it increases friction and the
potential for blade erosion and actually hinders the flow of steam, resulting in a lower
ing of turbine efficiency. The formation of moisture is delayed by superheating the
steam in the boiler. Superheating improves the economy of the turbine in two ways:
The additional heat increases the energy available for conversion into work, and it also
reduces friction.
The greater the pressure range through which the steam is expanded, the more is
the superheat required to prevent the formation of excessive moisture in the last stages
O p e rat i n g a n d M a i n ta i n i n g Ste a m Tu r b i n e s 527
of the turbine. The steam temperature is limited to about 1100°F by the metals available.
As metallurgy is advanced and materials are proven by experience, steam temperatures
are expected to increase.
Some turbines use a reheat cycle. This consists of passing the high-temperature and
high-pressure steam through a turbine, then returning it to a special superheater
(reheater) located in the boiler, and resuperheating it before it is expanded further in the
low-pressure turbine. This system makes it possible to have dry steam in all but the last
few stages of the turbine. It would be possible, but is seldom economically advisable, to
use more than one stage of reheating.
Turbines are well adapted to the utilization of high-pressure steam. At 100 to
150 psi pressure, there is a decrease in steam rate 1 of 11A percent for each 10 psi
increase in pressure. From 150 to 250 psi pressure, this decrease becomes % percent
for each 10 psi increase in pressure. At higher pressures, the reduction in steam rate
is lower.
Condensing turbines are operated effectively and efficiently with low backpressure
(vacuum) . Surface condensers are used, and the use of these condensers decreases
the steam rate by approximately 5 percent for each inch of mercury improvement in
vacuum within the range of 25 to 29 in. Hg. Exhaust pressures of 3.5 to 1.0 in. Hg are
common in modern power plants. Thus, by operating at a vacuum as created by the
condenser, the turbine can produce more power, just as it would with an increase in
steam pressure, but much more economically.
The impact and importance of a condenser that creates a vacuum can be illustrated
by the use of a simple equation for the thermal efficiency of a perfect heat engine or
turbine that ignores any losses due to radiation or friction:
T T
E= 1- z X 100
Tt
In this example, assume that the entering steam has a temperature of 400°F and that
the steam exhausts at atmospheric pressure, or 14.7 psia, which would have a steam
temperature of 212°F. Compare the efficiency of this heat engine or turbine with that of
a heat engine or turbine that has a condenser and a backpressure (vacuum) of 5 psia and
a steam temperature of 164°F. (Refer to steam tables.)
Without condenser:
860 - 672
E = x 100 2 1 . 8 percent
=
860
'Stearn rate is the number of pounds of steam supplied per unit of work, e.g., pounds per kWh.
528 C h a pter Te n
With condenser:
860 - 624
E = x 100 27.4 percent
=
860
Therefore, by the addition of a condenser, the efficiency is increased by nearly
6 percent. Although this is a simple example that ignores losses such as thermal radia
tion, it illustrates the goal for higher steam temperatures and for lower exhaust steam
temperatures to obtain higher efficiencies and thus lower fuel costs and produce higher
electric outputs.
Nothing is free, however, and with the use of a condenser, it is necessary to pump
large quantities of cooling water through it and the condensate also must be pumped
out of the condenser for its return to the boiler through feedwater heaters. Both these
actions require power, which reduces the effect of improved efficiency, and additional
capital costs are also necessary for the additional equipment. These added costs must be
evaluated against the improved efficiency. Since the majority of electric power plants
have condensers, this improvement in efficiency and power output has far exceeded
the additional costs in any economic evaluation.
1 . Fill all grease cups and oil the governor and other miscellaneous parts.
2. Open drains on the steam line, separator, casing, and exhaust lines. If these are
equipped with traps, open the bypass line.
3. Slowly open the exhaust-line shutoff valve.
4. If the turbine has a pressure lubricating system with an auxiliary oil pump,
start the pump.
5. Inspect the bearings for ample flow of oil; check the oil pressure and see if the
pump is operating properly (3-5 psi pressure is sufficient).
6. Turn on the cooling water for the bearings or oil cooler.
7. Open the throttle quickly to start the turbine. During this time observe the
turbine carefully for signs of rubbing (a small pipe or rod placed between the
ear and the points to be checked will aid in detecting unusual noise and rubbing,
or check the vibration monitoring equipment, if provided).
8. Slowly bring the turbine up to speed, approximately 300 rpm, and operate it at
this speed for a period of 15 to 30 min.
9. Trip the emergency valve by hand to see that it closes properly.
O p e rat i n g a n d M a i n ta i n i n g Ste a m Tu r b i n e s 529
10. Open the throttle wide and allow the governor to regulate the speed; keep a
close check to prevent overspeeding. Note: If the governor will not control the
speed at no load, the hand throttle may be used until the load is on.
11. Inspect the bearings to make certain that they are getting oil. Oil should be up
to the level recommended by the manufacturer. Usually the level drops when
oil fills all the various cavities in the system.
12. The drains, which were opened before the turbine was started, should now be
closed or arranged to discharge through the trap.
13. Gradually increase the load on the turbine while keeping a close check on the
oil, cooling water, and bearing temperatures.
Starting a medium-sized or large condensing turbine:
1. Inspect the governor mechanism, fill all grease cups, and oil as required.
2. If the boiler stop valve is not open, open it to permit as much heating of the
steam line as possible and avoid condensation in the line.
3. Open drains on the following: steam line, separator, throttle, and turbine casing.
4. Open the stop valve in the steam supply to the auxiliary oil pump. Note: The
operation of this pump is controlled by a governor to shut off the supply of
steam after the main oil pump has delivered oil at normal pressure; it opens
when the pressure fails.
5. Adjust needle valves to obtain 10 to 15 psi oil pressure on the main bearings
and 15 to 20 psi oil pressure on the thrust bearing; make sure gauges are in
operating condition and have been calibrated.
6. Start the condensing equipment, circulating pumps, and dry vacuum pump;
operate the condensate pumps as necessary to remove water during the
warming-up period.
7. The turbine steam or water seal should be turned on and the vacuum maintained
at 24 to 26 in. Hg during the warmup period; maintain approximately 1 psi
pressure in the packing chamber.
8. Turn on the water to the generator air cooler, and see that water flows properly
to this and other points requiring water.
9. If the drain ahead of the throttle valve has been closed for any reason, open it
again and keep it open until all water from condensation has been removed.
10. Now open the throttle valve quickly to set the rotor in motion.
11. As soon as the turbine is rolling, trip the overspeed by using the hand lever.
This is to determine if the tripping mechanism operates properly and to prevent
the turbine from accelerating too rapidly.
12. Reset the emergency overspeed valve, and before the turbine comes to rest,
adjust the throttle so that the turbine will operate between 200 and 300 rpm.
13. While the rotor revolves slowly, use a metal rod or listening device to determine
rubbing or mechanical difficulty, or observe the vibration monitoring equipment,
if provided.
530 C h a pter Te n
14. When the oil leaving the bearing reaches a temperature of approximately 110 to
120°F, start the circulating water through the oil cooler to maintain these
temperatures. At this time, the bearing oil pressure should again be checked.
15. Gradually increase the speed. The rate depends on the size of the turbine. Follow
the manufacturer 's instructions.
16. Adjust the water seal on the turbine and the atmospheric relief valve.
17. When normal operating speed has been reached and the turbine is under the
control of the governor, test the emergency governor by opening the valve in
the oil line to it. See that all valves controlled by this tripping mechanism
close promptly. Reset, open the throttle valve, and restore speed to normal.
18. If high-pressure packing is of the water-seal type, adjust the water to 15 psi
pressure and shut off the steam.
19. Close the drains mentioned in step 3.
20. Open the leak-off from the high-pressure packing so that any excess steam may
flow to the feedwater heater or to one of the lower stages of the turbine.
21. Synchronize the generator and tie it in the line.
22. With the throttle valve wide open, the speed is controlled by the governor. The
turbine is now ready for load and is regulated from the turbine control panel.
Note: Coordination of effort on all portions of the power plant is essential in placing
the turbine in operation.
It must be remembered that a large turbine has close clearances and that expansion
or improper operation is likely to cause more damage than in the case of a small unit.
Large turbines are provided with instruments, including oil-pressure gauges, temperature
indicators, and vibration monitors. These instruments should be observed at frequent
intervals and the readings recorded on the log sheet or plant computer. In addition to
the turbine, the condenser and other auxiliaries require attention, and this phase of the
operation must not be forgotten.
Note: Always read and follow the manufacturer 's instructions. These should be part
of the overall operating plan for the plant.
The turbine in motion:
2. Start the auxiliary oil pump, and make certain that the proper pressure is
maintained while the turbine is coming to a stop.
3. Trip the emergency valve. In most cases this valve also operates the vacuum breaker.
4. Close the leak-off from the high-pressure packing; admit steam to the chamber
at approximately 1 psi, and shut off the water.
5. Shut off the supply of cooling or condensing water.
6. Shut down the condensing equipment, and open the drains on the turbine piping
and casing.
7. Continue the auxiliary oil pump in operation until the turbine rotor has stopped.
8. If the turbine is to be left idle for a period long enough for it to cool to room
temperature, operate the condenser air pump to dry it out. In this way corrosion
can be avoided.
While a turbine is operating, it is good practice to keep a log sheet or a computer
ized record of the hourly readings of the instruments. These readings should be taken
by the operator while making a regular inspection. On modern units such information
is identified to the operator as part of the electronic control system, where the information
is also permanently recorded. Such a procedure prevents the operator from neglecting
some important inspection, and the data make a valuable record for future reference.
The number of readings to be taken depends on the size of the turbine and the number
of instruments installed. Some of the readings that might prove valuable are load on the
generator in megawatts, throttle steam pressure and temperature, exhaust pressure,
extraction pressure, temperature of cooling water entering and leaving the cooler, bearing
oil pressure and temperature, and the throttle steam-flow rate.
The proper application of oil to the bearings and a continuous flow of cooling water
are the main requirements of a turbine while it is operating. The operator detects trouble
on the inside of the turbine by noise or vibration or both. An appreciable drop in oil
pressure can be corrected by operating the auxiliary oil pump until there is an opportunity
to investigate the cause of the trouble.
Some small turbines have a number of hand-controlled individual nozzles for
admitting the steam. The operator can improve the economy by having a minimum
number of these nozzles open for the load at which the turbine is operating.
remembered that timely replacement of parts and adjustment for wear may prevent a
shutdown and save costly repairs.
Many operators find it economical and advisable to dismantle their turbines com
pletely and give them a thorough internal inspection once a year. Although this may be
desirable, experience has demonstrated that a turbine properly operated and main
tained can run for years without dismantling. In fact, the turbine is considered to be one
of the most reliable pieces of equipment in the entire plant. The merit of such inspec
tions, however, together with their frequency, is a matter of operating experience and
depends to a large extent on the age of the equipment and the service-hour record if it
is assumed that proper operation, etc., has been provided.
An annual inspection of a turbine would consist of examination of blading and
nozzles for wear, erosion and corrosion, cracks, and scale deposits; examination of main
bearings and the thrust bearing for wear; inspection of clearance between stationary
and moving parts and packing clearance; and thorough inspection of the oil pumps and
the various governor mechanisms.
Because turbines remain in service for longer periods of time, factors such as thermal
stresses, chemical attack from steam impurities, erosion, and corrosion all have become
real concerns to an operator. Operational situations such as process and load swings, plant
upsets, and extended turbine shutdowns with accompanying corrosion damage and
occasional boiler carry-over can affect turbine performance and its maintenance costs.
Maintenance and operating problems on large turbines that are found in electric
utilities are often attributable to
1 . Operating the turbine beyond its design life
2. Operating at continued outputs higher than design
3. Increased cycling operation on the turbine
Although operating at higher outputs and for longer periods of time than originally
planned can create fatigue stresses, cyclic operation is more of a problem. Solids carry
over to the turbine is a primary problem with cycling operation, and this can cause ero
sion in the high- and intermediate-pressure portions of the turbine and cause corrosion
in the low-pressure section. It is therefore very important to maintain high-quality boiler
feedwater so that carry-over is minimized. The major impurities that cause turbine cor
rosion are sodium hydroxide, sodium chloride, and various organic and inorganic acids.
The performance of steam turbines will deteriorate over time because of erosion,
corrosion, deposition, foreign-object damage, and seal degradation. These can degrade
performance by 15 percent depending on the severity of the problem.
The most significant cause of efficiency degradation is deposits along the steam
path as a result of boiler carry-over. Deposits are not only detrimental to efficiency but
also can have a drastic effect on turbine reliability because of increased thrust loading
and the possibility of stress-corrosion cracking of components from high levels of caustic
carry-over. Boiler water chemistry, therefore, is of critical importance. Water washing,
detergent soaking, grit blasting, and hand polishing are typical methods of removing
deposits.
Since turbine rotors rotate at high speed, one of the difficulties encountered is
vibration. Vibration in many cases is caused by unbalanced weight in the rotating parts
and misalignment of the shafts. Vibration due to an unbalanced condition changes with
the speed at which the machine is operating. It may be caused by broken, eroded, or
O p e rat i n g a n d M a i n ta i n i n g Ste a m Tu r b i n e s 533
corroded blades, by a bent shaft, by distortion due to unequal heating, or by scale deposits
on the blading.
Improper alignment of turbine and rotor shafts causes a vibration that does not
change with the turbine speed but which increases as the load on the turbine increases.
It might be caused by improper alignment of a new turbine. Foundation settling or
strains due to pipe expansion could cause vibration in a turbine that has been in operation
for some time.
Turbine vibration also occurs from water coming over from the boiler with the
steam, which will cause the turbine to become noisy and, in severe cases, will cause
vibration; electric-generator troubles, such as an unequal air gap or a loose coil in the
stator; internal rubbing of parts caused by warping of bladings or diaphragms,
improper adjustment, or worn thrust bearings; too much clearance in the main bear
ings; and overheating due to faulty lubrication or lack of cooling. Also, vibration may
result if the shaft becomes distorted as a result of heat generated by having the pack
ing rub.
The remedy for most of these difficulties immediately suggests itself: The different
parts of the equipment must be supported rigidly and aligned properly, the bearing
clearance must be within proper limits, and all bolts must be well tightened.
The rotor of the turbine is held in correct axial clearance by the thrust bearing
(see Fig. 9.24) and is adjusted with shims. The space provided for the shims is greater
than the internal clearance between the wheel and the nozzles on one side and the
stationary buckets on the other. With shims removed, the striking limits of the rotor can
be determined and measured at the bearing. Assuming a rotor with two rows of buckets
on the first wheel and with a total clearance of 0.160 in. or less, the thrust must be
shimmed so that the clearance is divided equally and the rotor is in midposition
between striking limits when washers are set. If wear occurs, a complete thrust bearing
should be ordered as an assembly; a spare should always be carried in stock.
Carbon packing rings are used at the high- and low-pressure ends of turbines that
operate condensing, on those turbines exhausting against high backpressure, and
where high initial steam temperature and pressure are used. Metallic packing rings are
placed at the shaft bore of diaphragms to minimize steam leakage along the shaft due
to the difference in pressure between the stages. The manufacturer 's recommendations
should be followed.
Proper maintenance of the emergency governor is likewise important. To ensure
proper operation, the governor should be tested at frequent intervals. All parts should
be kept clean and pins and bearings oiled. Alteration in the tripping speed on most
governors is accomplished by altering the number or thickness of shims. The emergency
governor should be tested weekly or when being placed in operation after an extended
outage.
Lubrication is of extreme importance to the successful operation of the turbine.
Proper lubrication of a steam turbine depends on the proper application of oil to the
bearings, the selection of a suitable oil, and maintenance of the oil in good condition
after it is in the turbine. The proper method of application of the oil to the bearing is part
of the turbine design. With use of the manufacturer 's recommendations, the operator is
responsible for selection of the proper oil and for keeping it in good condition after it is
in service in the turbine.
Oil having the proper viscosity must be selected. A thin oil is recommended, but
it must not thin out and lose its lubricating properties when heated to operating
534 C h a pter Te n
temperature. It should have the ability to separate readily from water. Some oils mix
with water and form sludge, which is very objectionable in the lubricating system.
Oil must be free from acid so that it will not corrode the highly polished surface of the
bearings. It must not give off volatile gases when heated to temperatures of 325 to
350°F. Oils that have their gases distilled off at low temperatures lose their lubricating
properties after they have been in use for some time. Some oils leave a sludge deposit
in lines, tanks, etc.
Oils in service pick up particles of dirt mixed with water and tend to become acid.
Medium-sized and large turbine installations have filters and cleaners for keeping the
oil in good condition. Several different methods are used: bypass filtration, in which part
of the oil is continually circulated through a filtration system; continuous filtration, in
which the entire amount of oil returning from the turbine is filtered; makeup system, in
which quantities of oil are drawn off at intervals and replaced with new or recondi
tioned oil; and batch treatment, in which all the oil in the turbine is removed and replaced
with new or reconditioned oil.
The oil pump, as well as the oil cooler, strainer, and other systems through which
the oil passes, should be kept in first-class condition. The worm and worm-gear teeth of
the pump should be inspected. To ensure the best lubrication, the oil should be with
drawn from the tank and the tank cleaned thoroughly. All openings, pipes, etc., should
be blown out with air or steam. Oil coolers require attention and should be removed
from service for the necessary maintenance.
Preventive maintenance, which includes inspections at frequent intervals, will
do much to keep the turbine in peak operating condition. The purpose of the above
mentioned inspections is to find possible sources of trouble before they have had an
opportunity to cause serious damage. Testing the emergency governor and checking
the operating governor are two points worth remembering.
A general inspection and maintenance procedure follows; however, specific proce
dures should be developed based on the manufacturer 's recommendations and the
plant's actual operating experience. On modern turbine generators, outages for major
inspections and maintenance generally occur every 5 years.
Weekly: Inspect the turbine exterior. Keep control-line valves free from dirt and
grease at the guides. Clean and oil the spindle of the throttle valve and connections
between levers of the governing mechanism, using a light oil to prevent gumming;
repair all oil leaks. Check all vibration measurements.
Monthly: Inspect the oil reservoir to determine if any sludge is accumulating or
any water is getting into the oil. Check the oil strainer. Check the operation of the
governor and automatic tripping devices and vacuum breakers. Observe the
governor operation to determine how it acts and whether it will carry the maximum
turbine load. If the turbine is operating at condensing, inspect the condensing
equipment and check the vacuum to see if it is the best obtainable with the
equipment and circulating-water temperatures. Check and verify instrumentation.
Yearly: Check turbine-generator alignment. Dismantle turbine and auxiliaries;
check for corrosion, dirt, scale, and fouled passages and for encrusted, corroded,
and eroded blading. Check for erosion on casing and nozzles. Check all valves
and seats. Check governor knife edges and bearing blocks and the emergency
tripping device. Check vacuum pumps and ejectors. Check for air leaks.
O p e rat i n g a n d M a i n ta i n i n g Ste a m Tu r b i n e s 535
A test should be made annually to check the spring calibration and to determine
the speed above normal at which the oil-tripped emergency governor will operate.
In operation, the emergency governor should be tested weekly. Testing the emergency
governor should be done after the turbine has been placed back in service or approxi
mately once a month.
1 . Attach a vibration tachometer to the turbine (or observe the permanent tacho
meter) so that it can be read by the person operating the throttle valve; the person
at the other end of the turbine should be provided with a hand tachometer.
2. Operate the throttle valve slowly to bring the turbine up to the required speed,
where the governor takes over.
3. Disconnect the governor beam from the vertical connecting linkage. Hold it
firmly to prevent it from closing the controlling valve. Lift it slowly, permitting
the control valve to open and the speed to increase slowly until the tripping
point is reached on the emergency governor. Do not permit the speed to exceed
the safe limit established.
4. Take tachometer readings to check the speed at which the emergency governor
operates.
5. If and when the emergency governor acts, check to see that the throttle valve
trips and speed decreases. If the emergency governor fails to operate, repeat all
the previous check points to determine what the problem might be.
6. Trip the emergency governor two or three times to make certain speed check is
correct and all parts are in working order.
7. Test the oil-tripped governor when shutting down the turbine by:
a . Running the turbine without load, throttle valve wide open, and turbine
Steam turbine losses generally fall into the following areas where improvements
can be made:
1. Bucket and nozzle losses are the result of friction between the steam and the
ports through which the steam flows. These losses can be reduced by a redesign
of the shape of the buckets and nozzles.
2. High-velocity steam from the last-stage turbine blades results in kinetic energy
lost to the condenser. This loss can be decreased by increasing the area through
which the steam flows, and one method is to increase the length of the last-stage
blades (LSB). The plant heat rate can be improved with this modification.
3. Losses due to steam leaks are the major contributor to the loss of turbine
efficiency. The primary source of leaks is from the shaft packing or around the
bucket tips. A change to the turbine to correct these losses often includes the
resizing of steam balance holes between the diaphragm packing and the rotor
or by adding tip sealing over the buckets.
4. When steam is contaminated with iron oxide, solid particles erode the turbine
blades, and performance degradation results. These deposits come from the
inside surfaces of the boiler and steam piping, and the problem in the turbine is
primarily in the first stage of the high-pressure turbine and the first stage of the
reheat or low-pressure turbine. Proper chemical cleaning of the boiler and water
treatment procedures must be followed strictly to prevent this serious problem.
10.2 Condensers
The condenser reduces the backpressure, thereby increasing the output and efficiency of the
turbine. The condensed steam becomes excellent feedwater and is returned to the boiler.
The vacuum created in the condenser depends on the cooling water temperature entering
the condenser, the effectiveness of the air-removal devices, and many other factors.
Some of the major areas of condenser operation that affect overall plant perfor
mance and turbine backpressure include cooling water temperature, temperature
differential between exhaust steam and inlet cooling water, degree of tube fouling, and
the velocity of the cooling water. Condenser fouling is common, especially when the
cooling water is from a natural source, such as a lake, river, or ocean. The fouling results
from sediment, scaling, corrosion, and biologic growth. When cooling water is part of a
closed system with a cooling tower, fouling of the condenser is minimized because the
water chemistry can be controlled and plugging from debris has been eliminated.
The operation of surface condensers can be enhanced by the following design and
operational features:
1. Avoid flow-induced vibration, which results in tube failures.
2. Incorporate proper steam flow distribution to ensure proper use of heating
surfaces.
3. Prevent air and circulating water leakage.
4. Maintain clean condenser tubes to ensure high performance.
When tubes become plugged with debris, proper backflush valve and piping arrange
ments can remove this debris. In addition, various mechanical and chemical water
treatment procedures are available to minimize fouling.
O p e rat i n g a n d M a i n ta i n i n g Ste a m Tu r b i n e s 537
H - (t0 - 32)
Q= t2 - t1
Example Assume the heat in the exhaust steam to be 1100 Btu; the temperature 10 = 100, 11 = 80, and
12 = 90. Calculate the amount of cooling water required to condense 1 lb of steam.
Solution
1 1 00 - (1 00 - 32) = 1 032
Q= 90 - 80 10
= 103.2 Ib (amount of water to condensel lb of steam)
In the preceding example, if the quantity of exhaust steam is 100,000 lb/h, then the
quantity of cooling water required would be
103.2 X 100,000 10,320,000 lb /h
=
or
gal h
gpm = 1 0,320,000 lb / h x 1 lb x 1min
8 . 33 60
= 20, 648 gpm
Compare this to the steam flow requirements of a utility boiler described in Chap. 2
where the boiler produces approximately 4,000,000 lb /h of steam. The cooling water
required for this unit would be 40 times greater than the above example, or approxi
mately 826,000 gpm. Thus, the cooling water requirements for a steam power plant are
very large and a very important part in the operation of the plant.
by running a chemical analysis on the condensate from time to time or by testing the
condensate to determine the resistance or conductivity of a given sample of water.
If a tube is split, temporary repairs may be made by driving a plug into the end of
the tube. Permanent repairs are made by replacing the tube. In the case of tubes
expanded in the tube sheet, care must be exercised to obtain a tight joint without bending
the tubes by overexpanding them.
Approximately SO percent of all tube failures occur within the first couple of inches
of the tube inlet end of the condenser. The inlet end of many heat exchangers also expe
riences this same failure. Erosion of the inlet end is the cause of these failures. As a
solution to this problem, a thin-walled metal tube insert, called a ferrule, is expanded
into the inlet end of a condenser or heat exchanger. Ferrules are approximately 6 in.
in length and are designed to ensure a smooth transition of the fluid at the inlet. The
ferrule is sacrificial and is designed to absorb the damage that otherwise would occur
on the condenser tube. The replacement of ferrules is far less expensive than replace
ment of the tube itself, and therefore many condenser designs incorporate the ferrule
inserts when the condensers are manufactured.
Air leaks that develop are difficult to detect and locate because of the large surface
area of the condenser and the many valves, fittings, and auxiliaries attached to it. These
leaks are detected by (1) examining all the joints for leaks using a candle, (2) filling
the entire condenser with water and maintaining a slight pressure on the system, and
(3) using low-pressure air and checking for leaks using a soap solution on the joints. The
leaks must be checked around all auxiliaries connecting the turbine seals, bleeder
connections, etc.; this is very often a slow and tedious job. Plastic compounds are often
used to seal the leaking joint when it is located.
A convenient method of determining the extent of leakage is to pull a vacuum on
the system and close down, permitting the unit to stand for a while. If the vacuum
drops more than 2 to 4 in. Hg per hour, it will be necessary to hunt for leaks. Another
method frequently used to determine whether the condenser is leaking air is to check
the pressure and see if the pressure in the condenser corresponds to the condensate
temperature. Should the pressure be higher, air leaks or noncondensable gases are present
in the condenser.
As an example, suppose the pressure in the condenser is 1 .932 in. Hg absolute
(0.9486 psia) and the temperature in the hot well is 96°F. Referring to the steam tables,
we find that at 96°F the pressure should be 1.729 in. Hg absolute, or 0.8488 psia. 2 Hence
the added or excess pressure is due to air or noncondensable gases that have leaked into
the condenser.
Condensers are sometimes equipped with metering devices to measure the air
removed from the condenser. These meters are usually calibrated in terms of cubic feet
of free air, at a given temperature, leaking into the condenser per unit of time.
Condensers are frequently troubled with scale and algae growth. These reduce the
heat transfer and at times become so serious as to interfere with the circulation of water.
Backwashing is sometimes effective in removing foreign material. Condensers
frequently have their piping so arranged that this can be accomplished while the
condensers are in service. Two-pass condensers often have a divided water box with
horizontal decks; one-half of the surface can be cut out of service for cleaning, while the
remainder carries the load, at reduced vacuum. This avoids interruption to operation
and, if done at low load, causes little inconvenience.
Scale can be removed by washing the tubes. Sediment inside the tubes can be
removed by blowing rubber plugs and compressed air through the inside of the tubes.
Algae growth is inhibited or destroyed by using various chemical solutions, depending
on the nature of the algae growth; at times, chlorine can be used very effectively. There
also have been systems developed for continuous tube cleaning that keep the condenser
operating at a high efficiency.
Since tube leaks are common and the plugging of tubes is the quickest repair, most
surface condensers are designed with excess surface so that plugged tubes will not
reduce design performance.
When replacing tubes or making repetitive adjustments, it is well to keep a continuous
record for future reference. Continued maintenance and repeated adjustments indicate
trouble that must be taken care of before the situation becomes serious.
The manufacturers of condensers are continually updating their maintenance pro
cedures based on operating experience in many plants, and they should be consulted
for maintenance recommendations.
and the electric power output. Not only is there lower output for the same initial steam
conditions, but also operating costs are higher due to higher fuel costs. The backpres
sures of turbines are in the range of 3.7 to 9 in. Hg with air-cooled steam condensers as
compared to 1 to 4.5 in. Hg for wet cooling tower systems under similar conditions.
the water or substance and not the total heat. When the wet- and dry-bulb temperatures
are the same, the relative humidity is 100 percent, and the air 's capacity to absorb addi
tional water vapor is zero. (Relative humidity is the ratio of the amount of water vapor
contained in the air to the amount that the air could contain if it was saturated.) Hence
the ability of a spray pond or cooling tower to give off heat contained in the water
depends on the wet-bulb temperature or relative humidity of the air with which it
comes into contact. Influencing factors that must be taken into consideration are wind
direction and velocity. The extent of cooling also depends on the area of the water
exposed to the air and the temperature of the water when it enters the basin. Cooling is
brought about by evaporation and conduction.
The degree to which the temperature of the water approaches the air wet-bulb
temperature is a measure of performance for the pond and cooling tower.
The wet-bulb temperature of the surrounding air is the theoretical point to which
water can be cooled. Usually it is not economical to approach closer than 5°F of the
wet-bulb temperature. The temperature drop (cooling range) will vary from 10 to 12°F
for a spray pond versus 12 to l 7°F for a mechanical-draft cooling tower. Since the
wet-bulb temperature of air varies geographically, it follows that the performance of
a cooling tower also will vary with its location. So the wet-bulb temperature record for
a given location must receive consideration when a tower is being designed.
The cooling pond is used where space adjacent to the power plant is plentiful and
where land is relatively inexpensive. Cooling ponds are also used in certain parts of the
country where atmospheric conditions are favorable. As an example, a cooling pond
located in an area where the relative humidity is usually low would prove more effec
tive than one installed in an area where the humidity approaches 100 percent. However,
as noted previously, sites that can incorporate a cooling pond are few.
The advantages of the forced-draft cooling tower (see Fig. 9.40) are that it is suitable
for corrosive waters; the fan can be mounted, firmly, close to the ground; and the fan is
accessible. Its disadvantages are recirculation of air with reduction in tower efficiency
(air leaving the tower exits at low velocity), higher fan power requirements and hence
increased operating cost, and increased maintenance. Also, since the size of the fan is
limited, more fans and foundations may be required.
The induced-draft cooling tower (see Fig. 9.41) discharges the air at a high velocity,
thereby avoiding recirculation; induced-draft fans are usually quiet in operation and
permit more uniform air distribution. However, they have several disadvantages: They
require a heavy superstructure, they must be perfectly balanced, and they are some
what difficult to service when major repairs are required.
of the tower, where storage is provided. From this point it is returned to the condenser
as required. This cycle is repeated again and again.
Air enters the side louvers, passing up and over the interior decking and cooling the
water. The air then is made to pass through the drift eliminators, where moisture carry
over is reduced to a minimum. Figures 9.45 and 9.46 show a double-flow cooling tower
operated by means of an induced-draft fan. Air and water pass in counterflow so that
the air is in contact with the hottest part of the water immediately before it leaves the
tower. Power costs are kept low by holding the flow of air to a minimum. Merely shutting
off the valve to the water distribution system reduces pumping costs, and air regulation
is obtained by operating the fan on a variable-speed motor.
To place an induced-draft cooling tower in service, open the makeup valves on the
tower to provide a sufficient amount of water storage. Open the valve to the tower outlet
and inlet, as well as valves on the condenser outlet. Now slowly open the inlet valve to the
condenser to permit water to fill the condenser and discharge piping. Next, close the valve
on the pump discharge and start the circulating pump, after which the valve on the pump
discharge can be opened slowly. This is to avoid the shock and vibration that might result
if the pump were placed on the line suddenly. Adjust the gates on the top of the tower to
obtain equal distribution of water to the various sections. Now start the fans. Make a routine
inspection of fans and motors to make certain that they are operating properly.
If the water temperature leaving the tower is lower than required, or if the turbine
load has been reduced so that not all the tower capacity is needed, reduce the fan speed
if two-speed motors are provided rather than take a cell out of service. The reason for
this is that it is less expensive to operate cells at half capacity or rating than to shut them
down and permit other cells to operate at top fan speed because reducing the load to
50 percent capacity reduces the horsepower or energy required to operate the fan. This is
so because the horsepower requirements vary with the cube of the speed of the fan, and
thus reducing the fan speed by 50 percent drops the fan horsepower to approximately
one-eighth full-load power requirements. This is an appreciable power saving and is the
reason why two-speed motors are used to take care of seasonal changes in load.
Should the load be further reduced and more than one circulating pump be pro
vided, take one pump out of service. Further load reductions will necessitate taking
cooling towers out of service or shutting fans down in multiple units and permitting
water to cascade from top to bottom.
Cold-weather operation introduces a few hazards that must be watched carefully.
To prevent icing, maintain the circulating water temperature as high as is practical.
For induced-draft cooling towers, several recommendations are provided.
1. Shut off the fans to the tower or run the motor at low speed.
2. Shut down cells and run the water over fewer compartments.
3. Bypass some of the water to the tower and reduce the number of cells operating.
4. If ice forms on the deck filling or louvers, shut down the fans temporarily while
continuing to circulate the water.
As a further precaution against the accumulation of ice, the fans are sometimes made
reversible. Also, the sump beneath the cooling tower can be provided with heating coils.
In the operation of cooling towers, an important item to consider is water treatment.
High water concentrations will deposit scale in the condenser heating surfaces, in the
piping transmission system, and in the tower. Low water concentrations result in higher
544 C h a pter Te n
operating costs because they waste water. Since most cooling towers are installed in
locations where water is a scarce or costly commodity, it is very easy to see why excess
blowoff is uneconomical.
Water concentrations build up because part of the original water is evaporated in
the heat transfer, while additional water is lost as drift or as entrained moisture in the
air passing through the tower. Evaporation accounts for a loss of approximately 1 percent
of the water for each l0°F range of water circulated. In a good cooling tower, drift is
usually less than 0.02 percent. The amount of blow down water wasted depends on the
hardness of the circulating water, the type of treatment used, and the drift loss. To con
trol the scale-forming solids at a satisfactory level, blowing down is resorted to. This is
done by testing the hardness of the water and by blowing down to keep the water
below the point where it would produce scale or where it would become corrosive.
Other factors that must be considered are the amount of dirt in the water or other
foreign material (depending on the location).
The pH value is important in controlling the chemical properties of cooling tower
water. Neutral water has a pH value of 7. Below this value the water is acid and tends to
be corrosive, while above 7 the water is alkaline and scale-forming. For cooling towers,
the pH of the circulating water is preferred to be between 6 and 8. If the pH value is
maintained too high, serious damage may result to the wooden cooling tower because
of delignification. This results in the dissolving of the lignin that binds the wood fibers
together, a condition that reduces the structural strength of the wood. This condition
first appears at points where the timbers are alternately wet and dry because here the
water concentration is increased due to the rapid evaporation. Sulfuric acid, zeolite, and
sodium hexametaphosphate are the chemicals most frequently used for treatment. If the
concentration of solids increases, the effective wet-bulb temperature will be raised.
Algae formation is also frequently experienced. This growth collects in the tower and
circulating system, reduces the heat transfer, and is a source of considerable trouble and
annoyance. It can be controlled by a number of chemicals, such as chlorine, copper sulfate,
potassium permanganate, and others. The type of algae growth determines the treatment
to be used. In general, proper water treatment requires the services of a qualified water
quality consultant to ensure that the proper treatment is used for the specific condition.
Inspection of equipment should be made at least once a shift. Usually mechanical
failures give first warning by excessive noise or vibration. Overheated motors can be
detected by feeling the motor. Vibration in fans is detected by peculiar noises and by
observing any vibration.
The overall size and performance of a cooling tower are affected by the heat-removal
requirements, the cooling-water temperature change, and the humidity at the site, all of
which vary seasonally. A hyperbolic cooling tower is also affected by the humidity and
other atmospheric conditions.
An operator must be prepared to handle potential operating problems, which include
As noted previously, during the operation of cooling towers in cold climates, the
formation of ice is an important concern. Special care should be given to the air intakes
and fill, where buildups of ice will jeopardize performance. One method of minimizing
severe buildup of ice on a mechanical cooling tower is to reverse the direction of the
fans, which shifts relatively warm water over the ice formation.
Also, many mechanical-draft cooling towers incorporate variable-speed fans. This
feature reduces power and thus operating costs when climatic conditions do not require
the design output of the fans. An economic evaluation of increased capital costs versus
lower operating costs and higher electric outputs must be performed in order to make
the correct decision.
10.4 Auxiliaries
intermittently. Operating costs can be reduced if the screen is run only when neces
sary. The frequency of operation can best be determined by installing an indicating or
recording gauge to notify the operator when the pressure drop (differential head or
water-level drop) across the screen has increased, indicating that the screen needs to
be cleaned. Allowance must be made, however, for the head of water on the inlet side
because the pressure drop across the screen will vary with the area exposed to the
inlet water.
The usual operation is to run the revolving screen at intervals frequent enough to
expose a new set of screens or buckets to the water flowing to the tunnel to avoid pres
sure drop across the screen. Since the pressure drop occurs because of foreign material
on the screen, the simplest way to determine whether screens are clean or dirty is to
operate as follows:
Assuming the water is 20 ft deep and each screen is 1 ft wide,
1. Turn the screens over slowly until all 20 ft (20 buckets) have been exposed.
Check the screens for foreign material.
2. If the screens are dirty, continue to run them until they begin to run clean.
3. Determine the frequency of running necessary to keep them in this condition.
Without a gauge, this is best determined by operating experience.
4. Once the frequency of rotation has been determined, a schedule can be set up
to rotate or raise the screens to the necessary height once each hour or less
frequently, depending on the condition of the water.
When starting the screen, operate at the slowest speed so that if interference
exists in the form of logs, etc., fouling will not occur with resulting damage, thus
requiring pulling the assembly from the well or sending a diver down to make an
inspection.
In certain seasons of the year more difficulty is experienced than at others, due to
seasonal rains, floods, etc., which increase the foreign matter carried along by the moving
stream. It is best under these conditions to run the screen continuously.
Care should be exercised to prevent freezing and damage to the screen if ice should
form in the intake during cold weather. To prevent this, screens are run continuously. In
some plants, all or part of the circulating water is discharged at the mouth of the intake
after leaving the condenser. This maintains the water above the freezing temperature
and prevents ice formation on the screens.
Most of these drives are equipped with automatic lubricators. If they are not so
equipped, lubrication must be applied while the screen is running. The motor should be
properly lubricated, and a coating of grease should be applied to the rollers on the rear
of each basket.
Preventive maintenance is the first step toward lower maintenance costs.
Weekly: Check the entire installation for rubbing, holes in the baskets, overloaded
motor, etc. Lubricate when necessary.
Monthly: Check the bearings on the sprocket drive, rollers, and bearings. Replace
damaged baskets.
Yearly: Replace all worn bushings and bearings and make a thorough and
complete check of all moving parts. Overhaul the motor, gear reducer, etc.
O p e ra t i n g a n d M a i nta i n i n g Ste a m Tu r b i n e s 547
10.4.2 Pumps
Of all the auxiliaries, the circulating water pump requires the most power because of
the large quantity of water that it handles. Most condensers are equipped with two
circulating water pumps, both operated at maximum load, while at partial load only
one is required to maintain the vacuum desired. Some circulating water pumps are
provided with two-speed or variable-speed motors to reduce operating cost to a
minimum.
Circulating water pumps are operated at relatively low speed and normally require
little attention once alignment has been made correctly. Properly lubricated, operated,
and maintained, circulating water pumps will run for extended periods of time without
difficulty.
Some pumps are set above the normal water level and have to be primed to be
placed in service. Priming is accomplished by evacuating the air in the pump until
water is ejected from the siphon. At this point the motor is started, and subsequently the
discharge valve is opened slowly so as not to lose the vacuum. The priming is then
discontinued.
If strainers are provided ahead of the pump, they must be inspected at frequent
intervals. If twin strainers are provided, the cleaning can be accomplished without
taking the pump out of service. If not, one condenser must be taken out of service for
this inspection. The cleanliness of the strainer can be determined by placing a set of
pressure gauges before and after the strainer and noting the pressure drop (loss) across
the strainer.
Circulating water pumps and condensate pumps are described in Chap. 8.
Example Assuming a barometer with a pressure of 29.50 in. Hg and a condenser vacuum of 27.25 in.,
determine the pressure difference in pounds per square inch.
Solution
10.2 For smaller utility or IPP plant sizes, why are significantly lower steam pressures and
temperatures used?
10.3 Describe, by use of a sketch, the flow of steam through a tandem compound turbine
consisting of a high-pressure turbine and a double-flow low-pressure turbine with the
steam from the low-pressure turbine exhausting to a condenser.
10.5 Other than to drive a generator for electric production, what types of equipment are
suitable to be driven by steam turbines?
10.8 If a higher superheat temperature offers higher turbine efficiency, why is there a steam
temperature limit of approximately 1100°F?
'Note:Because of environmental concerns, mercury gauges are being replaced with other types of
instrumentation.
O p e ra t i n g a n d M a i nta i n i n g Ste a m Tu r b i n e s 549
10.9 If a turbine produces more power by operating at higher steam pressures or by operating
at a vacuum at the exhaust, why not just increase the steam pressure?
10. 10 For modern power plants, what are common exhaust pressures in inches of mercury and
in pounds per square inch? Why are these pressures considered to be vacuums?
10. 1 1 Although the use o f condensers offers improvements i n power output and efficiency,
additional systems are necessary. These increase the capital costs of the plant and also
operating costs. List these required systems and added operating costs, and provide a
general evaluation on how they can be justified.
10. 12 What are the more important things to watch for in bringing a turbine on line? What is
important to monitor after it is on line and it is in operation? Why is a training program
important?
10.13 How often should a turbine be dismantled to receive a thorough inspection and overhaul?
10. 14 What types of operation have resulted in significant maintenance and operating problems
on large turbines?
10. 16 How is turbine performance affected over time? Where do the major losses occur, and how
can they be corrected?
10. 18 What is a common problem that affects performance of a condenser? Why is this minimized
when a cooling tower is part of the system?
10. 19 What maintenance problems can occur on a surface condenser? What is the impact on the
performance of the plant?
10.20 How would you proceed to determine whether a condenser was leaking? How would
you repair a tube leak? Would this have a significant impact on the performance of the
condenser?
10.2 1 How would you determine the reason for low vacuum that had suddenly occurred on a
condensing turbine?
10.22 What is used in condenser and heat exchanger tubing to minimize the potential for inlet
tube erosion?
10.23 List the operating advantages and disadvantages of an air-cooled steam condenser.
10.24 When are cooling towers selected to provide circulating water to condensers?
10.25 Define relative humidity and explain how it is determined. How does the relative humidity
of the outside air affect the operation of a cooling tower?
10.26 What is the advantage gained by having two-speed motors on a mechanical-draft cooling
tower?
10.27 In cold weather climates, what operational methods can be used on mechanical-draft
cooling towers to minimize icing problems?
10.28 Explain the operation of a traveling screen when it is used with a natural source of cooling
water.
550 C h a pter Te n
10.29 What is the purpose of a steam-jet ejector and a vacuum pump on a condenser?
10.30 The vacuum gauge reads 26.3 in. Hg and the barometer reads 30.03 in. Hg. What is the
absolute pressure in pounds per square inch?
10.3 1 The pressure of the atmosphere is 14.36 psi and the vacuum gauge reads 28.23 in. Hg. What
is the backpressure in pounds per square inch absolute (psia)?
10.32 A turbine operates with a backpressure of 1 .5 in. Hg. What is the pressure in pounds per
square inch (psi)?