Question:  
Refrigerant-134a is throttled from the saturated liquid state
a… Post a question
Answers from our experts for your tough
homework questions

Enter question
1. Refrigerant-134a is throttled from the saturated liquid state
at 700 kPa to a pressure of 160 kPa. Determine
the temperature drop
during this process and the final specific volume of the
refrigerant.

Answers: 42.3°C, 0.0344 m3/kg


Continue to post
18 questions remaining
Expert Answer

Badal Singh answered this


Was this answer helpful? 0 0
168 answers Snap a photo from your
phone to post a question
We'll send you a one-time download
link

888-888-8888 Text me

By providing your phone number, you agree to receive a one-time


automated text message with a link to get the app. Standard
messaging rates may apply.

My Textbook Solutions

Thermodyn... Electric... Electric...

8th Edition 1st Edition 0th Edition

View all solutions

Comment


Practice with similar questions

Q: Refrigerant-134a is throttled from the saturated liquid state at


700kPa to a pressure of 160kPa. Determine the
temperature drop
during this process and the final specific volume of the
refrigerant.

A: See step-by-step answer 100% (10 ratings)


Q: 5-62 Refrigerant-134a is throttled from the saturated liquid state at 700 kPa to a pressure of 160 kPa. Determine the
 temperature drop during this process and the final specific volume of the refrigerant.Answers: 42.3 degree C, 0.0345,
 Textbook Solutions Expert Q&A Study Pack Practice
m^2/kg


A: See answer

Show more 

Up next for you in Mechanical Engineering

A heat pump using R- A piston-cylinder device

134a
initially contains 0.35-kg
heats a house by using
of

underground water at 8 C steam at 3.5 MPa,

as
superheated by 7.4°C. See more questions
the heat source. The Now
for subjects you study
house is
the steam loses heat to
losing heat to the
the

See answer See answer

Questions viewed by other students

Q: Refrigerant-134a is throttled from the saturated liquid state at


700 kPa to a pressure of 160 kPa. Determine the
temperature drop
during this process and the final specific volume of the
refrigerant.

A: See answer 100% (1 rating)

Q: Refrigerant-134a is throttled from the saturated liquid state at 700 kPa to a pressure of 160 kPa. Determine the
temperature drop during this process and the final specific volume of the refrigerant.

A: See answer 100% (2 ratings)

Show more 

COMPANY

LEGAL & POLICIES

CHEGG PRODUCTS AND SERVICES

CHEGG NETWORK

CUSTOMER SERVICE

© 2003-2021 Chegg Inc. All rights reserved.

You might also like