“R” Required
“S” May be subcontracted, see OD 2012
“SF” Specialized Facility, see IECEE 02-2
“W” Witness testing in the categories “MED” and “MEAS”
“3PPS” Three Phase Power Supply required
Measurement / Testing / measuring equipment / material Characteristics of the Equipment
Clause Range used
testing needed
11 Heating Carpet as defined in IEC 60312 for automatic
battery-powered cleaners GCL-011:Digital power V: Max. 600 V, I:
meter/Yokogawa/WT310/C2PK10013V Max. 20 A, 0.1%
rdg
+ 0.05% rng
(50/60Hz) and DC
0.1% rdg + 0.2%
rng.
Appliances Glass surface inclined at 10° GCL-71: Statibility Testing Machine/ HANYANG/ FZ- 0-30 degree
powered by 1201/ Date 1-4-2021/1-4-2022
rechargeable
batteries
21 Mechanical Crushing test apparatus of current-carrying hoses
strength Abrasion test apparatus of current-carrying hoses
Flexing test apparatus of current-carrying hoses
Torsion test apparatus of current-carrying hoses
Cold cabinet (–15 °C ± 2 °C) for testing of
current-carrying hoses