LANGKAH
PROBLEM SUB COMPONENT ANALISA PENYEBAB
PEMERIKSAAN DAN PERBAIKAN
> RETARDER ABNORMAL > RETARDER SYSTEM > Saat diambil data dari operator, > LANGKAH PEMERIKSAAN
operator mengeluh retarder system Melakukan cek wiring harness retarder system:
abnormal. * check voltage selenoid retarder front and rear = 24V
> Indikator dipanel intermitten * check resistance selenoid front and rear = 22 ohm
* check voltage pressure switch retarder = 24V
hilang dan muncul saat problem
* check resistance wiring J03 pin 13 - RESWR pin 1 = 0,5 ohm
retarder abnormal. Check
* check resistance wiring J03 pin 14 - REVR pin 1 = 0,4 ohm
monitor panel didapati ada error * check resistance wiring J03 pin 15 - REVR pin 2 = 0,0 ohm
saat retarder abnormal (DX12MA, * check resistance wiring J03 pin 13 - D05 pin 1 = 0,5 ohm
DX11MA). * check resistance wiring J03 pin 16 - RESWF pin 1 = 0,2 ohm
* check resistance wiring J03 pin 17 - REVF PIN 1 = 0,3 ohm
* check resistance wiring J03 pin 18 - REVF PIN 2 = 0,3 ohm
* check resistance wiring BRC 1 pin 5 - J03 PIN 13 melalui dioda 05 = 0,46 V
Dari data diatas disimpulkan wiring harness retarder system (OK)
Selanjutnya melakuan pengecekan spool selenoid retarder front and rear
* check selenoid retarder (didapati temuan lock ring housing spool terlepas dari groove)
* check and inspection condition spool and groove
NOTE
Page 1