DEPARTMENT OF ELECTRICAL ENGINEERING

UNIVERSITY OF ENGINEERING AND TECHNOLOGY,


LAHORE, NAROWAL CAMPUS
EE 453: Power System Operation Date: Jun 24, 2020
and Control
Semester: 8th Time Allowed: 3 Hours
Examination: Home Exam Total Marks: 50
Session: 2016 Instructions: Open Books & Notes

Q Marks
1. a) The fuel cost functions for three thermal plants in $/h are given by
7

Find the optimal dispatch and the total cost in $/h for the above thermal plants when
the total load is 1000MW. Assume the initial value of λ=6.0$/MWh and the
following generator limits

b) The fuel-cost functions of two thermal plants in $/h are given by 7

The total load is 415MW. Determine the optimal dispatch of generation. Assume the
initial value of λ=7.0 $/MWh
CLO1
2. a) You have been given 3 electric power generating units. Clearly write down steps to 6
apply unit commitment to these units for 3 hours. In first hour the power demand is
200MW , In second hour the power demand is 400MW, In 3rd hour the power
demand is 300MW. CLO2
b) In applying unit commitment and economic dispatch why do you require reserve
2
generation capacity

3 a) Differentiate between abc and dq frame of reference, how these are interrelated 3
b) In the circuit of figure below let
R=0.250 Ω , L=15 mH , v(t)=150 sin(377t+⍺) . Determine the current response after 5
closing the switch for the following cases
i) No DC offset
ii) For maximum DC offset
PTO

.
CLO3

4 a) A 50-Hz synchronous generator having inertia constant H= 5MJ/MVA and a direct CLO4
axis transient reactance 𝑋𝑑′ = 0.3 𝑝. 𝑢 is connected to an infinite bus through a
purely reactive circuit as shown in figure below. Reactances are marked on the
diagram on a common system base. The generator is delivering a real power 𝑃𝑒 =
0.9 𝑝. 𝑢 and Q=0.064 p.u to the infinite bus at a voltage of V= 1p.u
i) A temporary three-phase fault occurs at the sending end of the line at point F.
4
when the fault is cleared both lines are intact. Determine the critical clearing
angle and the critical fault clearing time
ii) A three-phase fault occurs at the middle of one of lines, the fault is cleared, the 4
faulted line is isolated. Determine the critical clearing angle.

b) A four-pole 50-Hz synchronous generator has a rating of 150MVA, 0.8 power factor
lagging. The moment of inertia of the generator is 45,000 kg.𝑚2 . Determine M and
H.
5 a) An isolated power station has the following parameters CLO5
Turbine time constant 0.6 sec
Governor time constant 0.2 sec
Governor inertia constant H=6 sec 5
Governor Speed Regulation R=0.05 p.u
The load varies by 0.7 percent for a 1 percent change in frequency i.e D=0.7. The
turbine rated output is 250 MW at nominal frequency of 60 Hz. A sudden load
change of 50 MW Find steady-state frequency deviation
in Hz
b) Evaluate the performance of an electric power generating unit which is running
without automatic generation control(AGC) and automatic voltage regulator(AVR)
3

Good Luck !